Preview only show first 10 pages with watermark. For full document please download

Pmfy-p-vbm-e Databook

   EMBED


Share

Transcript

05_PMFY-P-VBM-E.qx:05_PMFY-P-VBM-E.qx 25/4/08 14:57 Page 1 Cassette ceiling R410A Data G4 PMFY-P-VBM-E A PMFY-P-VBM-E B C D E F 1. SPECIFICATIONS IU-C- 2 2. EXTERNAL DIMENSIONS IU-C- 3 3. ELECTRICAL WIRING DIAGRAMS IU-C- 4 4. SOUND LEVELS 4-1. Sound levels 4-2. NC curve IU-C- 5 IU-C- 5 5. TEMPERATURE/AIRFLOW DISTRIBUTIONS 5-1. Temperature distributions 5-2. Airflow distributions IU-C- 6 IU-C- 6 G H V-A V-B BC CT Cassette ceiling P20 P25 P32 P40 P50 P63 P71 P80 P100 P125 P140 P200 P250 0.8HP 1.0HP 1.3HP 1.6HP 2.0HP 2.5HP 2.8HP 3.2HP 4.0HP 5.0HP 5.6HP 8.0HP 10.0HP PMFY-P-VBM-E PMFY-P-VBM-E IU - C - 1 05_PMFY-P-VBM-E.qx:05_PMFY-P-VBM-E.qx 25/4/08 14:57 Page 2 1. SPECIFICATIONS R410A Data Model PMFY-P20VBM-E Power source Cooling capacity (Nominal) ✻1 ✻1 ✻1 ✻2 Power input Current input ✻3 Heating capacity (Nominal ) ✻3 ✻3 A B C D Power input Current input External finish External dimension H x W x D Net weight Decoration panel E F Heat exchanger FAN G H V-A V-B BC CT Model External finish Dimension HxWxD Net Weight Type x Quantity External static press. Motor type Motor output Driving mechanism Airflow rate (Low-Mid-High) kW kcal / h Btu / h kcal / h kW A kW kcal / h Btu / h kW A mm in. kg (lb) PMP-40BM mm in. kg (lb) Pa mmH2O kW m3 / min L/s cfm dB Noise level (Low-Mid-High) (measured in anechoic room) Insulation material Air filter Protection device Refrigerant control device Connectable outdoor unit Liquid Diameter of (R410A) mm (in.) refrigerant pipe (R22, R407C) Gas (R410A) mm (in.) (R22, R407C) Field drain pipe size mm (in.) External Drawing Wiring Refrigerant cycle Document Standard Accessory attachment Remark 2.2 1,900 7,500 2,000 0.042 0.20 2.5 2,200 8,500 0.042 0.20 6.5 - 7.2 - 8.0 - 8.7 108 - 120 - 133 - 145 230 - 254 - 283 - 307 27 - 30 - 33 - 35 ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare PMFY-P25VBM-E PMFY-P32VBM-E 1-phase 220-240V 50Hz, 1-phase 220V 60Hz 3.6 2.8 3,100 2,400 12,300 9,600 3,150 2,500 0.044 0.044 0.21 0.21 4.0 3.2 3,400 2,800 13,600 10,900 0.044 0.044 0.21 0.21 Galvanized, with grey insulation sheet 230 x 812 x 395 9-1/16" x 32" x 15-9/16" 14 (31) PMP-40BM PMP-40BM MUNSELL (0.98Y 8.99/0.63) 30 x 1,000 x 470 1-3/16" x 39-3/8" x 18-9/16" 3 (7) Cross fin (Aluminum fin and copper tube) Line flow fan x 1 0 0 1-phase induction motor 0.028 Direct-driven by motor 7.3 - 8.0 - 8.6 - 9.3 7.3 - 8.0 - 8.6 - 9.3 122 - 133 - 143 - 155 122 - 133 - 143 - 155 258 - 283 - 304 - 328 258 - 283 - 304 - 328 32 - 34 - 36 - 37 32 - 34 - 36 - 37 Polyester sheet PP honeycomb fabric Fuse LEV R410A, R407C, R22 CITY MULTI ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare O.D. ø26 (1") IU-BH01-C184 IU-RG79-A671 G4 PMFY-P40VBM-E 4.5 3,900 15,400 4,000 0.054 0.26 5.0 4,300 17,100 0.054 0.26 PMP-40BM 7.7 - 8.7 - 9.7 - 10.7 128 - 145 - 162 - 178 272 - 307 - 343 - 378 33 - 35 - 37 - 39 ø6.35 (ø1/4") Flare ø6.35 (ø1/4") Flare ø12.7 (ø1/2") Flare ø12.7 (ø1/2") Flare Installation Manual, Instruction Book Drain hose I.D. ø26 (1") (flexible joint) Optional parts Decoration panel PMP-40BM PMP-40BM PMP-40BM PMP-40BM *PMFY-P-VBM-E should used together with PMP-40BM Installation Note : Indoor : Outdoor : Pipe length : Level difference : Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to the Installation Manual. ✻1 Nominal cooling conditions 27˚CDB/19˚CWB (81˚FDB/66˚FWB) 35˚CDB (95˚FDB) 7.5 m (24-9/16 ft) 0 m (0 ft) ✻2 Nominal cooling conditions 27˚CDB/19.5˚CWB (81˚FDB/67˚FWB) 35˚CDB (95˚FDB) 5 m (16-3/8 ft) 0 m (0 ft) ✻3 Nominal heating conditions 20˚CDB (68˚FDB) 7˚CDB/6˚CWB (45˚FDB/43˚FWB) 7.5 m (24-9/16 ft) 0 m (0 ft) Unit converter kcal/h Btu/h cfm lb = kW x 860 = kW x 3,412 = m3/min x 35.31 = kg / 0.4536 *Above specification data is subject to rounding variation. * Nominal conditions ✻1, ✻3 are subject to JIS B8615-1. * Due to continuing improvement, above specification may be subject to change without notice. Ref.: Spec_PMFY-P20VBM-E PMFY-P-VBM-E IU - C - 2 Refrigerant pipe(liquid) OD ø6.35 outer side of grille (96) 141 Ceiling Drain pan panel Same line Left side Ceiling panel 176 Refrigerant pipe(gas) OD ø12.7 395 302 254 96 ceiling opening 74.5 26 43 46 ø50 200 Panel(grille):PMP-40BM 600 759 Drain pan Air outlet(lower) 812 1000 outer side of grille 960 ceiling opening 811 suspension bolt pitch 759 20 1000 outer side of grille Lower view 200 Front ( 56) Drain pipe PVC pipe: O.D. 26 (1") 430 20 20 198 (10) 470 suspension bolt pitch 340 28 28 45 45 230 (20) 17.5 17.5 20 Outer line of grille 53 20 74.5 26 30 Electrical box Center of unit 20 outer side of grille 247 69 Top 40 60 PMFY-P-VBM-E 470 Gas pipe Liquid pipe pipe cover PVC pipe: O.D. 26 (1") OD ø12.7(1/2") OD ø6.35(1/4") OD ø43 Panel(grille):PMP-40BM Suspension bolt(M10 or W3/8) Installation space required around indoor unit Terminal block for transmission Right side Terminal block for power supply Knock out 250 Detail drawing of fresh air intake hole Fresh air intake hole 288.5 ø 100 4-ø2.8 Burring hole * Drain hose I.D. 26 (1") flexible joint ······· Accessory 1pc. Drain pipe Refrigerant piping 22 110 ø1 235 or more Mounting plate 14:57 230 25/4/08 110 05_PMFY-P-VBM-E.qx:05_PMFY-P-VBM-E.qx Page 3 2. EXTERNAL DIMENSIONS R410A Data PMFY-P20,25,32,40VBM-E G4 Drw. : IU-BH01-C184 Unit : mm A B C D E F G H V-A V-B BC CT IU - C - 3 108 05_PMFY-P-VBM-E.qx:05_PMFY-P-VBM-E.qx 25/4/08 14:57 Page 4 3. ELECTRICAL WIRING DIAGRAMS R410A Data PMFY-P20,25,32,40VBM-E Drw. : IU-RG79-A671 FUSE BREAKER PULL BOX (15A) (15A) POWER SUPPLY TO NEXT ~/N 220-230-240V 50Hz INDOOR UNIT 220V 60Hz TO OUTDOOR UNIT BC CONTROLLER ME REMOTE CONTROLLER DC24-30V TB5 M1 M2 (SHIELD) PE TO MA-REMOTE CONTROLLER DC8.7-13V 5 1 2 ORN ORN A MF BLU BLU RED BLU GRN/YLW TB2 L N I.B B C D E FAN (WHT) 1 2 3 4 5 6 F RED G BLU H FUSE 3 1 CND (RED) POWER ZNR T V-B DP BLU BC 1 3 CNP (YLW) D.U.M X1 X1 SW2 SW3 SW4 ON OFF (RED) ADDRESS CN43 SW1 1 2 3 4 5 6 7 8 9 10 SW12 SW11 O 0 0 3RD. 2ND. 1ST. DIGIT DIGIT DIGIT (RED) ADDRESS SWC SW14 CN82 0 CONNECTION No. (WHT) REMOTE SWITCH CN32 1 3 8 7 6 5 4 3 2 1 (RED) ADDRESS CN42 1 2 3 4 TH23 2 1 TH22 TH21 BLU BRN ORN YLW RED WHT LEV BRN RED ORN YLW GRN 1 2 3 MV 4 5 CN25 2 1 (RED) ADDRESS CN81 CN27 1 2 3 4 5 6 7 8 4 8 NAME SYMBOL I.B INDOOR CONTROLLER BOARD HUMIDIFIER CN25 DAMPER CN27 REMOTE SWITCH CN32 CONNECTOR HA TERMINAL-A CN41 CENTRALLY CONTROL CN51 CN52 REMOTE INDICATION SW2 CAPACITY CODE SW3 SWITCH MODE SELECTION SW4 MODEL SELECTION ZNR VARISTOR FUSE FUSE(6.3A/250V) X1 AUX.RELAY DRAIN PUMP T TRANSFORMER LED1 POWER SUPPLY(I.B) LED2 POWER SUPPLY(I.B) A.B CIRCUIT BOARD SW1 MODE SELECTION SW5 VOLTAGE SELECTION SW11 SWITCH ADDRESS SETTING 1ST DIGIT SW12 ADDRESS SETTING 2ND DIGIT SW14 CONNECTION NO. 6 2 1 12345 A.B 4 3 2 1 2 1 2 1 0N 0FF 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 DS 6 5 CN6V 4 (GRN) VANE 3 2 1 CT *See fig:✻1 3 2 1 6 5 CN60 4 (WHT) LEV 3 2 1 4 CN41 (WHT) HA 1 5 CN51 (WHT) CENTRALLY CONTROL 1 CN52 5 (GRN) REMOTE INDICATION 1 V-A BLU TB15 CN3A CN2M (BLU) 1 2 (BLU) 1 2 REMOCON CN31 M-NET (WHT) DRAIN LED2 CN29 (BLK) GAS CN21 (WHT) LIQUID CN20 (RED) INTAKE LED1 SW5 220V 240V G4 <✻1> SYMBOL MF MV DP DS TB2 TB5 TB15 TH21 TH22 TH23 LEV NAME FAN MOTOR VANE MOTOR DRAIN WATER LIFTING-UP MACH. DRAIN SENSOR POWER SUPPLY TERMINAL TRANSMISSION BLOCK MA-REMOTE CONTROLLER ROOM TEMPERATURE DETECTION (0˚C/15kΩ, 25˚C/5.4kΩ) THERMISTOR PIPE TEMPERATURE DETECTION/LIQUID (0˚C/15kΩ, 25˚C/5.4kΩ) PIPE TEMPERATURE DETECTION/GAS (0˚C/15kΩ, 25˚C/5.4kΩ) LINEAR EXPANSION VALVE MODELS P20 SW2 SW3 0N 0FF 0N 0FF 123456 7 8 9 10 123456 P25 0N 0FF P32 0N 0FF P40 0N 0FF 0N 0FF 123456 7 8 9 10 123456 0N 0FF 123456 7 8 9 10 123456 0N 0FF 123456 1 2 3 4 5 6 7 8 9 10 NOTES: 1.At servicing for outdoor unit, always follow the wiring diagram of outdoor unit. 2.Symbol [S] of TB5 is the shield wire connection. 3.Symbols used in wiring diagram above are, :terminal block, :connector. 4.The setting of the SW2 dip switches differs in the capacity for the detail, see the table <✻1>. 5.Please set the switch SW5 according to the power supply voltage. Set SW5 to 240V side when the power supply is 230 and 240 volts. When the power supply is 220 volts, set SW5 to 220V side. PMFY-P-VBM-E IU - C - 4 05_PMFY-P-VBM-E.qx:05_PMFY-P-VBM-E.qx 25/4/08 14:57 Page 5 4. SOUND LEVELS R410A Data G4 4-1. Sound levels PMFY-P-VBM-E Sound level at anechoic room : Low-Middle2-Middle1-High Sound level dB (A) 27-30-33-35 PMFY-P20VBM-E PMFY-P25VBM-E PMFY-P32VBM-E PMFY-P40VBM-E 32-34-36-37 1.5m 33-35-37-39 A B Measurement location C * Measured in anechoic room. D E F G H V-A V-B BC CT 4-2. NC curves 70 High speed Middle1 speed Middle2 speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCIES (Hz) 8000 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa 70 PMFY-P25,32VBM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 220V, 60Hz 70 High speed Middle1 speed Middle2 speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 OCTAVE BAND CENTER FREQUENCIES (Hz) PMFY-P-VBM-E PMFY-P40VBM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 220V, 60Hz 8000 OCTAVE BAND PRESSURE LEVEL (dB) 0dB = 20μPa PMFY-P20VBM-E External static pressure : 0Pa Power source : 220,230,240V, 50Hz / 220V, 60Hz High speed Middle1 speed Middle2 speed Low speed 60 NC60 50 NC50 40 NC40 30 NC30 20 NC20 10 Approximate minimum audible limit on continuous noise 0 63 125 250 500 1000 2000 4000 8000 OCTAVE BAND CENTER FREQUENCIES (Hz) IU - C - 5 05_PMFY-P-VBM-E.qx:05_PMFY-P-VBM-E.qx 25/4/08 14:57 Page 6 5. TEMPERATURE/AIRFLOW DISTRIBUTIONS R410A Data G4 5-1. Temperature distributions Flow angle 30˚ Flow angle 70˚ <˚C> <˚C> 2.7 2.7 19 2 21 23 23 25 Height B 2 33 Height A 1 24 30 24 1 27 25 C 21 25 D 5 4 3 2 1 5 0 4 Floor distance 3 2 1 0 Floor distance E F G H Note : These figures show typical temperature distributions in the conditions above. In the actual installation, they may differ from these figures under the influence of air temperature conditions, ceiling height, cooling/heating load,obstacles,etc. V-A V-B BC 5-2. Airflow distributions Flow angle 30˚ Flow angle 70˚ 2.7 2.7 3.0 3.0 1.0 2 Height 2 Height CT 2.0 1 2.0 1 1.0 0.5 0.5 0.5 5 4 3 2 1 0 Floor distance 5 4 3 2 1 0 Floor distance Note : These figures show typical airflow distributions in the conditions above. In the actual installation, they may differ from these figures under the influence of air temperature conditions, ceiling height, cooling/heating load,obstacles,etc. PMFY-P-VBM-E IU - C - 6