Control Unit Ex e, Panel Mount, LED Indicator
Features
PML.LG.L.W.2
Assembly
• LED indicator, green - 12 ... 250 V AC/ DC • Ex de and Ex tb certified • Full equipment certified • Polyamide housing for panel mount • Installation in Zone 1, Zone 2, Zone 21 and Zone 22 • Cable Gland M20 integrated in protective cover • Degree of protection IP66
Release date 2017-05-31 11:52
Date of issue 2017-05-31
297363_eng.xml
Technical data Electrical specifications Operating voltage Operating current Terminal capacity Terminal torque Function Color Rated operating voltage Mechanical specifications Cable type Clamping range Covering Cover fixing Degree of protection Cable entry Number of cable entries Material Housing Finish Seal Washer gasket Mass Dimensions Height Width Depth Actuator head diameter
250 V max. 16 A max. 2x 2.5 mm2 1.1 Nm LED indicator green 12 ... 250 V AC/DC non-armored cables 5.5 ... 13 mm (D) Protective cover fully detachable Phillips head screw IP66 1x M20 cable gland in protective cover Polyamide (PA) inherent color black silicone silicone 150 g max. 77 mm (A) 44 mm (B) 105 mm (C) 39 mm (D2)
Refer to "General Notes Relating to Pepperl+Fuchs Product Information". Pepperl+Fuchs Group USA: +1 330 486 0002 Germany: +49 621 776 2222 www.pepperl-fuchs.com
[email protected] [email protected]
Singapore: +65 6779 9091
[email protected]
1
Control Unit Ex e, Panel Mount, LED Indicator
Panel wall thickness Diameter thru-hole Length outside enclosure Width across flats Total length Tightening torque Nut torque at enclosure Mounting Ambient conditions Ambient temperature Data for application in connection with hazardous areas EU-Type Examination Certificate Marking
PML.LG.L.W.2
1 ... 6 mm (PT) 30.6 mm (DT) 23.6 mm (H) 24 mm (SW1) 136.1 mm (L) 2 Nm (SW1) via actuator head -40 ... 50 °C (-40 ... 122 °F)
CML 16 ATEX 3106 X ¬ II 2 GD Ex de IIC T6 Gb Ex tb IIIC T80 °C Db
International approvals IECEx approval Conformity Degree of protection General information Supplementary information
IECEx CML 16.0046X EN 60529 EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperlfuchs.com.
Dimensions L H
SW1
D2
PT
DT
D2
C
A
B
D 1
2
3
4
5
6
7
8
Legend
Release date 2017-05-31 11:52
Date of issue 2017-05-31
297363_eng.xml
1
Cable gland
2
Protective cover
3
Contact module
4
Bayonet catch
5
Locknut
6
Panel / enclosure wall
7
Flat gasket
8
Actuator head
A
Height
B
Width
C
Depth
D DT
Clamping range, cable sheath diameter Diameter thru-hole
D2
Outer diameter actuator head
H
Length outside enclosure
L PT
Total length Panel / enclosure wall thickness