Transcript
Program Distribution Amplifier
PO-9106
Features • Six Balanced Transformer-Isolated Outputs with XLR Connectors • One Electronically Balanced Input with XLR Connector • Level Control on Each I/O with LED Display • AC or 24VDC Operation • Rack Mount (1RU)
Description The PO-9106 is a high-quality program distribution amplifier. It allows the proper distribution of signals, using balanced transformer-isolated outputs. The signal can be distributed to six output channels via balanced XLR connectors. The unit features independent level control on all input and output channels with a peak indicator on the front panel. The PO-9106 can be powered by 100-120VAC or 220240VAC 50/60Hz (depending on country requirements) and/or 24VDC, enabling connection to a standby power supply for emergency operation. The unit is packaged in a 1.7" high (1RU) rack-mount enclosure.
Technical Specifications ELECTRICAL Channels Frequency Response THD Input Sensitivity/Impedance Input Level Adjustment Output Level/Impedance Signal-to-Noise Ratio GENERAL Power Source Power Consumption W eight Dimensions (W x H x D)
PO-9106 One Input, Six Outputs 20Hz - 20kHz < 0.1% 100mV/600Ω Balanced -20dB +4dB/600Ω Balanced >75dB 100-120VAC or 220-240VAC 50/60Hz; 24VDC 8W 10.2lbs. 3.8kg 19" x 1.7" x 11" 482mm x 44mm x 280mm
PO-9106 Architects and Engineers Specifications The PO-9106 shall be a single-rackspace program distribution amplifier. It shall allow the distribution of signals using balanced transformerisolated outputs. The signal shall be distributed up to six output channels via balanced XLR connectors. The unit shall feature independent level controls on all input and output channels with a peak indicator on the front panel.
The program distribution amplifier shall meet the following performance criteria: Frequency response shall be from 20Hz to 20kHz, while total harmonic distortion shall be less than 0.1%. Signal-to-noise ratio shall exceed 75dB. Input sensitivity and impedance shall be 1V@600Ω.
The program distribution amplifier shall measure 19"(482mm) wide x 1.7"(44mm) high x 11"(280mm) deep. The unit shall be packaged in a rackmount enclosure. The program distribution amplifier shall be powered by 100-120VAC or 220-240VAC 50/ 60Hz (depending on country requirements) and/or 24VDC, enabling connection to a standby power supply for emergency operation. The program distribution amplifier shall be an Inter-M model PO-9106.
PO-9106 Front and Rear Views
Inter-M Americas, Inc. • 1 E. Beacon Light Lane • Chester, PA 19013 Tel: 610-874-8870 • Fax: 610-874-8890 • E-mail:
[email protected] Website: www.inter-m.net Inter-M Corp. (Korea) • 653-5 Banghak-Dong • Dobong-Ku • Seoul • Korea
Tel: 82-2-2289-8140~8 • Fax: 82-2-2289-8149 • E-mail:
[email protected] Website: www.inter-m.com © 2004 Inter-M Specifications subject to change without notice. PO910603045M
PO - 9106 PROGRAM DISTRIBUTOR
FEATURES
SPECIFICATIONS
PROGRAM DISTRIBUTION
ELECTRICAL
The signal distributes from 1 channel input program to 6 channel output program for the convenient use of signal transmission.
·Input Sensitivity/Impedance .............100mV/600Ω ,BAL ·Input Level Adjustment .........................................-20dB ·Output Level/Impedance .....................+4dB/600Ω, BAL ·Frequency Response ................................20Hz~20kHz ·T.H.D(at 1kHz Rated Output) ................Less than 0.1% ·S/N ......................................................Better then 75dB ·Channels .............................................1 Input, 6 Output
INDECENT LEVEL ADJUSTMENT Input and 6 channel output level is able to adjust independently, and each status of level is able to monitor with peak or signal LEDs on each channels.
*0dB=0.775Vrms
GENERAL TRANSFORMER BALANCED CIRCUIT(OPTION) All input and output are designed with electronic balanced circuit and XLR connection, and line matching transformer is mountable optionally.
·Power Source.....AC 120V/230V/240V, 50/60Hz, DC 24V ·Power Consumption .................................................8W ·Weight ...................................................................3.8kg ·Dimensions .......................482(W)×44(H)×280(D)mm
PO-9106 POWER SWITCH
INPUT PEAK LED
PO-9106 PROGRAM DISTRIBUTOR
POWER
CHANNEL1
INPUT LEVEL
CHANNEL3
CHANNEL2
CHANNEL4
CHANNEL5
CHANNEL6
PEAK
ON
OFF M IN
M AX
-
INPUT LEVEL CONTROL
+4dB
-
-
+4dB
+4dB
-
-
+4dB
+4dB
-
+4dB
OUTPUT LEVEL CONTROL 1~6
AC INLET
OUTPUT JACK CHANNEL 1~6
230
S/N FUSE T315mAL/ 250V
DC INPUT 24V
+ OUTPUT
INPUT
INPUT JACK
CH 6
CH 5
CH 4
CH 3
CH 2
CH 1
DC INPUT
BLOCK DIAGRAM
OFFICE : 653-5 BANGHAK-DONG, DOBONG-KU, SEOUL, KOREA TEL : 82-2-2289-8140~8, FAX : 82-2-2289-8149 Home page : http://www.inter-m.com E-mail :
[email protected]
9047912710 B