Preview only show first 10 pages with watermark. For full document please download

Point Of Interface Solution(poi)

   EMBED


Share

Transcript

POI Solution Proprietary Information: For internal use only © Copyright RFM Wireless Ltd. 1. Point Of Interface Multi Band Combiner  Description Point of interface (POI) is a platform for multi-combining system for Base station and DAS It combines several mobile carriers(operators) BTS or DAS system two or four output port(Comport) for distributed antenna system. At the same time, it distributes the different uplink signals to their each system, realizing multi-band and multi-signal combination and using simple two or four Com Antenna ports This is a feasible and efficient measure of realizing the coverage by signals from multi-networks.  Key Features • • • • • • • High Performance and high reliability Cost effective antenna sharing solution for outdoor and indoor applications 19 inch Rack Type. Effective in time and installation as it easy and fast. Support building esthetical aspect by reducing number of indoor antenna. Multi band Support. Good isolation good power handling ability and excellent IMD. Proprietary Information: For internal use only 2. Application For BTS Interface BTS Interface POI Block Diagram Proprietary Information: For internal use only Application For DAS Interface DAS System Interface POI Block Diagram BTS POI Master Unit Remote Unit HYBRIDE1 DL DL BTS J1 800 , 900MHz 1 1+2+3+4 No Damage Protection Circuit 2 1+2+3+4 3 1+2+3+4 4 1+2+3+4 LTE+GSM+DCS+UMTS_TX DL MU1 RU1 LTE+GSM+DCS+UMTS_RX UL UL DPX1 LTE+GSM+DCS+UMTS_TX DL MU2 RU2 LTE+GSM+DCS+UMTS_RX UL J2 1800 ,1900MHz BTS DL No Damage Protection Circuit MU3 DL J3 1700 , 2100MHz 1+2+3+4 1 1+2+3+4 2 No Damage Protection Circuit UL RU3 LTE+GSM+DCS+UMTS_RX LTE+GSM+DCS+UMTS_TX DL UL BTS DPX3 DL J4 LTE 700MHz 2600MHz LTE+GSM+DCS+UMTS_TX DL UL DPX2 No Damage Protection Circuit UL DPX4 BTS Proprietary Information: For internal use only UL 1+2+3+4 3 1+2+3+4 4 HYBRIDE2 UL MU4 RU4 LTE+GSM+DCS+UMTS_RX 3. Application Point of interface solution (Example 16IN 4OUT) Proprietary Information: For internal use only 4. POI Picture & Out Drawing Picture of 12:4 POI Proprietary Information: For internal use only Out Drawing 5. CDMA + GSM900 + GSM1800 + UMTS_16:4 POI Electronical Specification ITEM 16:4 POI Block Diagram Specification CDMA 800 : 824 ~844 & 869~889MHz GSM 900 : 890~915MHz & 935~960MHz Frequency range GSM 1800 : 1710~1880 MHz UMTS: 1920~2170 MHz CDMA: 9.5 dB GSM 900: 9.5 dB Insertion Losses GSM 1800: 10.5 dB UMTS: 8.0 dB Return Loss 18dB Rejection 50dB @CDMA-GSM @the remainder Ports : 80 dB Port Port Isolation 20dB In/Out Port DIN(F) CDMA:2Port GSM 900: 3 Port No of Input Ports DCS1800:8 Ports UMTS: 3 Ports No of Out put Ports 4Ports In/Out Impedance 50 Ohm Inter Modulation, 150dBc @2x43dBm TX Carrier Operating temperature Range -10℃ to +55℃ Power Handling Capability Input Power:50Watt each Port Proprietary Information: For internal use only 6. LTE + CDMA + AWS + PCS + G BLOCK_16:4 POI Electronical Specification 16:4 POI Block Diagram ITEM Specification Frequency range LTE 700 : 698 ~ 787 MHz CDMA850 : 824 ~ 889MHz AWS : 1710~1755 & 2110~2115MHz PCS+G Block : 1850 ~ 1995MHz LTE 700 : 8.5 dB Insertion Losses CDMA 850 : 8.5dB AWS: 8.5 dB PCS+G Block: 8. 5 dB Return Loss 18dB Rejection At Others Port 80dB Port Port Isolation 20dB In/Out Port DIN(F) LTE: 4Port CDMA850: 4 Port No of Input Ports AWS: 4 Ports PCS: 4 Ports No of Out put Ports 4Ports In/Out Impedance 50 Ohm Inter Modulation @2x43dBm TX Carrier 150dBc Operating temperature Range -10℃ to +55℃ Proprietary Information: For internal use only 7. CDMA + GSM900 + GSM1800 + UMTS_14:4 POI Electronical Specification ITEM 14:4 POI Block Diagram Specification CDMA 800 : 824 ~844 & 869~889MHz GSM 900 : 890~915MHz &935~960MHz Frequency range GSM 1800 : 1710~1880 MHz UMTS: 1920~2170 MHz CDMA: 9.5 dB GSM 900: 9.5 dB Insertion Losses GSM 1800: 10.5 dB UMTS: 8.0 dB Return Loss 18dB Rejection 50dB @CDMA-GSM @the remainder Ports : 80 dB Port Port Isolation 20dB In/Out Port DIN (F) CDMA:2 Port GSM 900: 2 Port No of Input Ports DCS1800:8 Ports UMTS: 2 Ports No of Out put Ports 4Ports In/Out Impedance 50 Ohm Inter Modulation, 150dBc @2x43dBm TX Carrier Operating temperature Range -10℃ to +55℃ Power Handling Capability Input Power:50Watt each Port Proprietary Information: For internal use only 8. CDMA + GSM1800 + UMTS 12:4 POI Electronical Specification Specification Frequency range CDMA 800: 824~889MHz GSM 1800 : 1710~1880MHz UMTS 2100 : 1920~2170MHz Band-Width (BW) CDMA 800 : 65MHz GSM 1800 : 170MHz UMTS 2100 : 250MH CDMA800 CDMA IN1 GSM1800 GSM IN1 UMTS2100 UMTS IN1 Hybrid Coupler1 Output1 Insertion Loss ±0.5dB Min Return Loss 18dB Min Isolation 75dB Min@ each path I/P & O/P Ports 12 for in put port & 4 for Output port In/Out Impedance 50 Ohm Dimensions 480X250X176 (Unit: mm) GSM1800 GSM IN2 UMTS2100 UMTS IN2 CDMA800 CDMA IN3 GSM1800 GSM IN3 UMTS2100 UMTS IN3 Output3 All Port DIN(F) IMD 150dBc @ 43dBm x 2tone Operating temperature Range -10℃ to +65℃ Power Handling Capability Input Power:50Watt each Port Proprietary Information: For internal use only CDMA IN4 GSM1800 GSM IN4 UMTS2100 UMTS IN4 COMBINER 4 CDMA800 RF Connector Output2 COMBINER 3 Pass band Ripple CDMA IN2 COMBINER 2 CDMA800 CDMA 800: 8.5dB GSM 1800: 8.5dB UMTS 2100: 8.5dB COMBINER 1 ITEM 12:4 POI Block Diagram Output4 Hybrid Coupler2 9. LTE + CDMA + AWS + PCS + G BLOCK_8 : 2 POI Electronical Specification 8:2 POI Block Diagram ITEM Specification Frequency range LTE 700 : 698 ~ 787 MHz CDMA850 : 824 ~ 889MHz AWS : 1710~1755 & 2110~2115MHz PCS+G Block : 1850 ~ 1995MHz LTE 700 : 5.5 dB Insertion Losses CDMA 850 :5.5dB AWS: 5.5 dB PCS+G Block: 5.5 dB Return Loss 18dB Rejection At Others Port 80dB Port Port Isolation 20dB In/Out Port DIN(F) LTE: 2Port CDMA850: 2 Port No of Input Ports AWS: 2 Ports PCS: 2 Ports No of Out put Ports 2Ports In/Out Impedance 50 Ohm Inter Modulation @2x43dBm TX Carrier 150dBc Operating temperature Range -10℃ to +55℃ Proprietary Information: For internal use only 10. LTE + CELLULAR + PCS + AWS_6:3 POI Electronical Specification ITEM 6:3 POI Block Diagram Specification LTE : 698 ~ 787 MHz CELL : 824 ~ 889MHz Frequency range PCS : 1850 ~ 1990 MHz LTE AWS : 1710~1755 & 2110~2155MHz Term. Cell 850 Insertion Losses 9.5dB Return Loss 18dB AWS LTE @ other band 80 dB CELL @ other band 80 dB Rejection LTE PCS @ other band 80 dB AWS @ other band 80 dB Port Port Isolation 20dB In/Out Port DIN(F) Term. PCS AWS LTE: 2PortS CEL: 1 Port No of Input Ports PCS:1 Port AWS: 2 Ports No of Out put Ports 3Ports In/Out Impedance 50 Ohm Inter Modulation, 140dBc @2x43dBm TX Carrier Operating temperature Range -10℃ to +55℃ Power Handling Capability Input Power:40Watt each Port Proprietary Information: For internal use only Output 1 Output 2 Output 3 11. 4 BAND DAS SYSYEM POI POI Block Diagram Proprietary Information: For internal use only Electronical Specification ITEM Specification Remark 824 ~ 849MHz 1850 ~ 1910MHz Up Link 1710 ~ 1755MHz 698~716 and 777 ~798MHz US Type 869 ~ 894MHz 1930 ~ 1990MHz Down Link 2110 ~ 2155MHz 728~768MHz Frequency Range 880 ~ 915MHz 1710 ~ 1785MHz Up Link 1920 ~ 1980MHz 698~716 and 777 ~798MHz Europe Type 925 ~ 960MHz 1805 ~ 1880MHz Down Link 2110 ~ 2170MHz 728~768MHz CDMA, GSM, UMTS, LTE (700) Supported Services Service Bands 800, 850, 900, 1800, 1900 1700, 2100 700 (4G) Band 1 Band 2 Band 3 Band 4 Up Link Down Link 824 ~ 849MHz 9.5dB 1850 ~ 1910MHz 9.5dB 1710 ~ 1755MHz 9.5dB 698~716 777 ~798MHz 9.5dB 11.0dB 869 ~ 894MHz 9.5dB 1930 ~ 1990MHz 9.5dB 2110 ~ 2155MHz 9.5dB 728~768MHz 9.5dB 880 ~ 915MHz 9.5dB 1710 ~ 1785MHz 9.5dB 1920 ~ 1980MHz 9.5dB Insertion loss Up Link Down Link 698~716 9.5dB 777 ~798MHz 11.0dB 925 ~ 960MHz 9.5dB 1805 ~ 1880MHz 9.5dB 2110 ~ 2170MHz 9.5dB 728~768MHz 9.5dB Proprietary Information: For internal use only US Type Europe Type Electronical Specification ITEM Specification Up Link Remark 824 ~ 849MHz 1.5dB 1850 ~ 1910MHz 1.5dB 1710 ~ 1755MHz 1.5dB 698~716 777 ~798MHz 869 ~ 894MHz 1.5dB 1.8dB 1.5dB 1930 ~ 1990MHz 1.5dB 2110 ~ 2155MHz 1.5dB 728~768MHz 880 ~ 915MHz 1.5dB 1.5dB 1710 ~ 1785MHz 1.5dB 1920 ~ 1980MHz 1.5dB 698~716 777 ~798MHz 925 ~ 960MHz 1.5dB 1.8dB 1.5dB 1805 ~ 1880MHz 1.5dB 2110 ~ 2170MHz 1.5dB US Type Down Link Ripple Up Link Down Link 728~768MHz 1.5dB Return loss 15dB Min RF input power 0dBm (DL to POI) No damage RF input power 40W- 50W Max. RF input power +20dBm (DL to POI) Max. RF Output power -40dBm (UL to BTS) Number of Service Bands 4 Proprietary Information: For internal use only Europe Type Environmental Specifications ITEM Specification Operating temperature Range Humidity Dust and water protection -20° to 85° C 95% non condensing IP 40 Remark Mechanical Specifications ITEM Specification Dimensions Weight Around 19”Rack 2U Around 20Kg 19” Rack mount All Port N (F) 2C Gray Color Mounting Option RF Connector Finish Proprietary Information: For internal use only Remark With terminations on all ports