Preview only show first 10 pages with watermark. For full document please download

Polophone Intercom System Entry Panel Wiring Diagram Commissioning Pre2007

   EMBED


Share

Transcript

COMMISSIONING FOR COMPREHENSIVE INSTRUCTIONS REFER TO THE POLOPHONE INSTALLATION MANUAL REFERENCE: 1163.D.01.0001_2 1 2 B A Entry Panel Selector Switch and Volume Control CENTURION SYSTEMS (PTY) LTD CENTURION THE AUTOMATIC CHOICE WEB: http://www.centsys.co.za Sharecall Number: 0860 103 726 General information e-mail: [email protected] POL phone to have and to hold POL POL Entry Panel Selector Switch and Volume Control ! If the system has only one entry panel set the selector switch (A) to the upper position or (1). ! If there are two entry panels set the selector switch on the one panel to the upper position (1) and on the other panel to the lower position (2). ! When adjusting the speech volume start by setting the control knob (B) approximately 75% of full volume. Clockwise rotation increases the volume. Having set the volume adjustment on all the handsets to the same volume then optimise the speech volume at the entry panel(s). Latest Revision: 24.11.2006 COMMISSIONING Entry Panel Selector Switch and Volume Control ! If the system has only one entry panel set the selector switch (A) to the upper position or (1). ! If there are two entry panels set the selector switch on the one panel to the upper position (1) and on the other panel to the lower position (2). ! When adjusting the speech volume start by setting the control knob (B) approximately 75% of full volume. Clockwise rotation increases the volume. Having set the volume adjustment on all the handsets to the same volume then optimise the speech volume at the entry panel(s). FOR COMPREHENSIVE INSTRUCTIONS REFER TO THE POLOPHONE INSTALLATION MANUAL REFERENCE: 1163.D.01.0001_2 1 2 B A Entry Panel Selector Switch and Volume Control CENTURION SYSTEMS (PTY) LTD WEB: http://www.centsys.co.za CENTURION THE AUTOMATIC CHOICE Document Ref: 1163.D.01.0002_5 POL phone to have and to hold Sharecall Number: 0860 103 726 General information e-mail: [email protected] Latest Revision: 24.11.2006 Document Ref: 1163.D.01.0002_5 WIRING DIAGRAM ENTRY PANEL HANDSET 1 2 1 2 -+ 1 2 NO COM 1 2 -+ -+ NO COM NO COM 1 2 1 2 _ + B NO COM A 1 2 _ + -+ See Note Below 1 2 _ + See Note Below _ + NO NO NO NO COM COM COM COM POWER SUPPLY FOR DOOR STRIKE EXTRA HANDSETS AUXILIARY OUTPUT/POTENTIAL FREE NORMALLY OPEN - GATE PEDESTRIAN OPENING - PILLAR LIGHT CONTROL - ENTRANCE LIGHT CONTROL BATTERY SUPPLY NOTES: Power Supply DOOR STRIKE TRG COM POTENTIAL FREE NORMALLY OPEN CONTACT TO ACTIVATE GATE MOTOR ETC. 1. Only one 12V DC Power Supply is typically needed to power the system. 2. Power can be connected to any component in the system. 3. The diagram shows the 12V Battery Supply of gate motor connected to the entry panel to power the system. 4. If power is being connected to the handset use either a mains adapter with a DC jack compatible with the socket provided (A) or connect 12-14V DC to the terminals (B). B. WARNING If the gate trigger wire is connected to a potential free contact (NO or COM) on the entry panel, the gate can be opened by joining the NO and COM terminals together. For additional security it is advisable to wire to the auxiliary terminals on the handset or connect the PoloSwitch in the gate motor. WIRING DIAGRAM ENTRY PANEL HANDSET 1 2 1 2 -+ 1 2 NO COM 1 2 -+ -+ NO COM NO COM 1 2 1 2 _ + 1 2 _ + -+ B _ + See Note Below NO COM A See Note Below 1 2 _ + NO NO NO NO COM COM COM COM POWER SUPPLY FOR DOOR STRIKE EXTRA HANDSETS AUXILIARY OUTPUT/POTENTIAL FREE NORMALLY OPEN - GATE PEDESTRIAN OPENING - PILLAR LIGHT CONTROL - ENTRANCE LIGHT CONTROL BATTERY SUPPLY NOTES: Power Supply TRG COM POTENTIAL FREE NORMALLY OPEN CONTACT TO ACTIVATE GATE MOTOR ETC. DOOR STRIKE 1. Only one 12V DC Power Supply is typically needed to power the system. 2. Power can be connected to any component in the system. 3. The diagram shows the 12V Battery Supply of gate motor connected to the entry panel to power the system. 4. If power is being connected to the handset use either a mains adapter with a DC jack compatible with the socket provided (A) or connect 12-14V DC to the terminals (B). B. WARNING If the gate trigger wire is connected to a potential free contact (NO or COM) on the entry panel, the gate can be opened by joining the NO and COM terminals together. For additional security it is advisable to wire to the auxiliary terminals on the handset or connect the PoloSwitch in the gate motor.