Preview only show first 10 pages with watermark. For full document please download

Pon Series Eols-gu-35-xx Series

   EMBED


Share

Transcript

PON Series EOLS-GU-35-XX Series Class C+ ONU for GPON Single Fiber Bi-Directional WDM Transceiver 1.244Gbps Upstream and 2.488Gbps Downstream RoHS6 Compliant Features  SFP Package With SC Receptacle  1.244Gbps, 1310nm Burst Mode Transmitter  2.488Gbps, 1490nm Continuous Mode Receiver  Un-cooled DFB Laser and APD High Sensitivity Detector  Class 1 FDA and IEC60825-1 Laser Safety Compliant  Operating Case Temperature Applications  GPON System ℃~+70℃ Industry: -40℃~+85℃ Standard: 0  Fiber to the Home, Curb, Office (FTTx)  Compliant with ITU-T G.984.2 and G.984.2 Amendent-2006  Compliant with SFP MSA Specification Ordering Information Part No.*Note1 Input/ Output Burst-mode EOLS-GU-35-D DC/AC LVTTL High Burst LOS/SD DDMI Interface Temp. SD YES SC Standard EOLS-GU-35-DA DC/AC LVTTL Low Burst SD YES SC Standard EOLS-GU-35-DI DC/AC LVTTL High Burst SD YES SC Industry EOLS-GU-35-DIA DC/AC LVTTL Low Burst SD YES SC Industry EOLS-GU-35-DJ DC/AC LVTTL Low Burst LOS YES SC Standard EOLS-GU-35-DK DC/AC LVTTL High Burst LOS YES SC Standard EOLS-GU-35-DIJ DC/AC LVTTL Low Burst LOS YES SC Industry EOLS-GU-35-DIK DC/AC LVTTL High Burst LOS YES SC Industry Note1: Standard Version, For other ordering information in detail , please contact EOPTOLINK. Eoptolink Technology Inc., Ltd. Page 1 of 8 V1.a PON Series Regulatory Compliance* Product Certificate Certificate Number Applicable Standard EN 60950-1:2006+A11+A1+A12+A2 EN 60825-1:2014 EN 60825-2:2004+A1+A2 TUV R50135086 UL E317337 EMC CE AE 50285865 0001 FCC FDA ROHS WTF14F0514417E / / UL 60950-1 CSA C22.2 No. 60950-1-07 EN 55022:2010 EN 55024:2010 47 CFR PART 15 OCT., 2013 CDRH 1040.10 2011/65/EU *The above certificate number updated to June 2014, because some certificate will be updated every year, such as FDA and ROHS. For the latest certification information, please check with Eoptolink. Product Description Eoptolink’s high performance GPON ONU transceiver is designed for passive optical network application. It can fully support the Class C+ ODN application specified by the ITU-T G.984.2 standard and ITU-T G.984.2 Amendent1. It is fully compliant with IEEE 802.3ah-2004. The GPON ONU transceiver is packaged of small form package with SC connector. The digital diagnostic monitoring function is fully compliant with SFP MSA. The module consists of 1310nm un-cooled DFB Laser, InGaAs preamplifier and WDM filter in a high-integrated optical sub-assembly. It transmits 1.244Gbps at 1310nm in burst mode and receives 2.488Gbps at 1490nm in continuous mode. Absolute Maximum Ratings*Note2 Parameter Symbol Min. Max. Unit Storage Temperature TS -40 +85 °C Supply Voltage VCC -0.5 4.0 V Operating Relative Humidity - 95 % Wave Soldering Conditions Temp/Time - 260/10 °C/s *Note2: Exceeding any one of these values may destroy the device immediately. Recommended Operating Conditions Parameter Operating Case Temperature Symbol Tc Min. Typical Max. EOLS-GU-35-DX 0 - 70 EOLS-GU-35-DIX -40 - 85 Unit °C Power Supply Voltage VCC 3.15 3.3 3.45 V Power Supply Current ICC - - 300 mA Date Rate Upstream/Downstream - 1.244/2.488 - Gbps Eoptolink Technology Inc., Ltd. Page 2 of 8 V1.a PON Series Performance Specifications – Electrical Parameter Symbol Min. Typ. Transmitter Max Unit Notes LVPECL and CML Compatible Inputs(Differential) Vin 300 - 1600 mVpp DC coupled inputs Input Impedance (Differential) Zin 85 100 115 ohm Rin > 100 kohm @ DC Tx ON / Burst Enable VIH 2 Tx Off / Burst Disable VIL 0 Tx ON / Burst Enable VIL 0 Tx Off / Burst Disable VIH Burst Control Vcc EOLS-GU-XXDB/K 0.8 V - 0.8 EOLS-GU-XXDA/J 2 - Vcc Receiver CML Outputs (Differential) Vout 600 - 1000 mVpp Output Impedance (Differential) Zout 85 100 115 ohm 2 - Vcc+0.3 V 0 - 0.8 V Vcc+0.3 V RX_SD Normal SD AC coupled outputs 2 I C Serial Logic I2C Serial Data I2C Serial Clock SDA_H 2 - SDA_L 0 - 0.8 V SCL_H 2 - Vcc+0.3 V SCL_L 0 - 0.8 V Performance Specifications – Optical Parameter Symbol Min. Typical Max. Unit Date Rate (Upstream/Downstream) R - 1.244/2488 - Gbps 1280 1310 1360 nm Transmitter Centre Wavelength λC -20dB Spectral Width Δλ - - 1 nm Side Mode Suppression Ratio SMSR 30 - - dB Average Output Power Pout 0.5 - 5 dBm ER 10 - - dB - 0.15 0.26 ns (Note4) Extinction Ratio* Rise/Fall Time (Optical, 10%~90%) tR,tF Output Optical Eye*(Note5) ITU-T G984.2 Compliant Optical Burst On/ Off Time t_on/t_off - - 12.8 ns Additive Jitter Generation JA - - 0.2 UI Eoptolink Technology Inc., Ltd. Page 3 of 8 V1.a PON Series (Note3) Optical Output Power with TX OFF* P_off - - -45 dBm 1480 1490 1500 nm Receiver Centre Wavelength λc (Note6) Receiver Sensitivity* Pmin - - -30 dBm Saturation Optical Power Pmax -8 - - dBm Damage Threshold PDT - - 4 dBm Receiver Reflectance CR - - -20 dB 0.5 Polarization Dependent Loss PDL - - LOS Assert LOSA -42 - LOS De-Assert LOSD (Note7) LOS Hysteresis* 0.5 dB dBm - -31 dBm 2 6 dB. Note3: Measured with 9/125um G.652 SMF. 23 Note4: Filtered, measured with PRBS2 -1 test pattern @1.244Gbps. Note5: Eye Pattern Mask. Note6: Measured with a PRBS 223 -1 test pattern @2.488Gbps and ER=10dB, BER 1X10-12. Note7: LOS Hysteresis(SD signal coincides with the LOS signal inversion) Transmitter Burst Mode Timing Characteristics Eoptolink Technology Inc., Ltd. Page 4 of 8 V1.a PON Series Power Supply Power supply < 3V Burst control Data Input Optical Output X X OFF > Disable X OFF Power supply 3.13V Enable NO Other Yes Laser bias and modulation signal output “X” means don’t care. “Other” means peak power less than +8dBm. “High/Low” means Logic high/low level. “No” means data not present, “Yes” means data present. “OFF” means the optical power less than -45dBm. Burst transmitter timing Enhanced Digital Diagnostic Interface The memory map in the following describes an extension to the memory map defined in SFF-8472 MSA. The enhanced interface uses the two wire serial bus address 1010001X (A2H) to provide diagnostic information about the module’s present operating conditions. Eoptolink Technology Inc., Ltd. Page 5 of 8 V1.a PON Series SFP Pin Function Definitions Pin No. Pin Name Description 1 VeeT Tx Ground 2 Tx Fault Indicate the TX fail. Burst Control LVTTL input. The default setting is that laser output is disable when this pin is asserted high and laser output is enabled when this pin is asserted low or laser output is disable when this pin is asserted low 3 ( and laser output is enabled when this pin is asserted high. BEN ) 4 MOD_DEF(2) 2-Wire Serial Data I/O Pin.(SDA) 5 MOD_DEF(1) 2-Wire Serial Clock Input.(SCL) 6 MOD_DEF(0) Internally Grounded 7 TX_SD Tx Transmitter State Indication, Assert high when Transmitter ON. Or to the ground directly if not use. 8 LOS/SD Set LOS is that active high when signal is detected. (LVTTL); While the setting is SD,it active low when signal is detected. (LVTTL); Can be selected via specific part number. 9 NC Not Connect 10 VeeR Rx Ground 11 VeeR Rx Ground 12 RXD- 13 RXD+ Non-Inverted Receiver Data Output (AC-Coupled internally) 14 VeeR Rx Ground 15 Vcc_RX Rx Vcc 16 Vcc_TX Tx Vcc 17 Veet Tx Ground 18 TXD+ Non-Inverted Transmitter Data Input (DC-Coupled) 19 TXD- 20 Veet Tx Ground F Mounting Studs Inverted Receiver Data Output (AC-Coupled internally) Inverted Transmitter Data Input (DC-Coupled) Eoptolink Technology Inc., Ltd. Page 6 of 8 V1.a PON Series Recommend Circuit Schematic Mechanical Specifications SC Receptacle Eoptolink Technology Inc., Ltd. Page 7 of 8 V1.a PON Series Laser Emission Obtaining Document You can visit our website:http://www.eoptolink.com Or contact Eoptolink Technology Inc., Ltd. Listed at the end of the documentation to get the latest documents. Revision History Revision Initiated Review Approve Description Release Date V1.a Oliver Lyn/Jason/ Nygai Phlio Released Nov 19, 2015 Notice: Eoptolink reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. Eoptolink makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Contact: Add: Floor 5, Building 2, No. 21 Gaopeng Avenue, High-Tech District, CHENGDU, SICHUAN 610041 P.R. CHINA Tel: (+86) 028-85122709 ext 816 & 809 Fax: (+86) 028-85121912 Postal: 610041 E-mail:[email protected] http://www.eoptolink.com Eoptolink Technology Inc., Ltd. Page 8 of 8 V1.a