Transcript
PON Series EOLS-GU-35-XX Series Class C+ ONU for GPON Single Fiber Bi-Directional WDM Transceiver 1.244Gbps Upstream and 2.488Gbps Downstream RoHS6 Compliant
Features SFP Package With SC Receptacle 1.244Gbps, 1310nm Burst Mode Transmitter 2.488Gbps, 1490nm Continuous Mode Receiver Un-cooled DFB Laser and APD High Sensitivity Detector Class 1 FDA and IEC60825-1 Laser Safety Compliant Operating Case Temperature
Applications GPON System
℃~+70℃ Industry: -40℃~+85℃ Standard: 0
Fiber to the Home, Curb, Office (FTTx)
Compliant with ITU-T G.984.2 and G.984.2 Amendent-2006 Compliant with SFP MSA Specification
Ordering Information Part No.*Note1
Input/ Output
Burst-mode
EOLS-GU-35-D
DC/AC
LVTTL High Burst
LOS/SD DDMI Interface
Temp.
SD
YES
SC
Standard
EOLS-GU-35-DA
DC/AC
LVTTL Low Burst
SD
YES
SC
Standard
EOLS-GU-35-DI
DC/AC
LVTTL High Burst
SD
YES
SC
Industry
EOLS-GU-35-DIA
DC/AC
LVTTL Low Burst
SD
YES
SC
Industry
EOLS-GU-35-DJ
DC/AC
LVTTL Low Burst
LOS
YES
SC
Standard
EOLS-GU-35-DK
DC/AC
LVTTL High Burst
LOS
YES
SC
Standard
EOLS-GU-35-DIJ
DC/AC
LVTTL Low Burst
LOS
YES
SC
Industry
EOLS-GU-35-DIK
DC/AC
LVTTL High Burst
LOS
YES
SC
Industry
Note1: Standard Version, For other ordering information in detail , please contact EOPTOLINK.
Eoptolink Technology Inc., Ltd. Page 1 of 8
V1.a
PON Series Regulatory Compliance* Product Certificate
Certificate Number
Applicable Standard EN 60950-1:2006+A11+A1+A12+A2 EN 60825-1:2014 EN 60825-2:2004+A1+A2
TUV
R50135086
UL
E317337
EMC CE
AE 50285865 0001
FCC FDA ROHS
WTF14F0514417E / /
UL 60950-1 CSA C22.2 No. 60950-1-07 EN 55022:2010 EN 55024:2010 47 CFR PART 15 OCT., 2013 CDRH 1040.10 2011/65/EU
*The above certificate number updated to June 2014, because some certificate will be updated every year, such as FDA and ROHS. For the latest certification information, please check with Eoptolink.
Product Description Eoptolink’s high performance GPON ONU transceiver is designed for passive optical network application. It can fully support the Class C+ ODN application specified by the ITU-T G.984.2 standard and ITU-T G.984.2 Amendent1. It is fully compliant with IEEE 802.3ah-2004. The GPON ONU transceiver is packaged of small form package with SC connector. The digital diagnostic monitoring function is fully compliant with SFP MSA. The module consists of 1310nm un-cooled DFB Laser, InGaAs preamplifier and WDM filter in a high-integrated optical sub-assembly. It transmits 1.244Gbps at 1310nm in burst mode and receives 2.488Gbps at 1490nm in continuous mode.
Absolute Maximum Ratings*Note2 Parameter
Symbol
Min.
Max.
Unit
Storage Temperature
TS
-40
+85
°C
Supply Voltage
VCC
-0.5
4.0
V
Operating Relative Humidity
-
95
%
Wave Soldering Conditions Temp/Time
-
260/10
°C/s
*Note2: Exceeding any one of these values may destroy the device immediately.
Recommended Operating Conditions Parameter Operating Case Temperature
Symbol Tc
Min.
Typical
Max.
EOLS-GU-35-DX
0
-
70
EOLS-GU-35-DIX
-40
-
85
Unit °C
Power Supply Voltage
VCC
3.15
3.3
3.45
V
Power Supply Current
ICC
-
-
300
mA
Date Rate
Upstream/Downstream
-
1.244/2.488
-
Gbps
Eoptolink Technology Inc., Ltd. Page 2 of 8
V1.a
PON Series Performance Specifications – Electrical Parameter
Symbol Min. Typ. Transmitter
Max
Unit
Notes
LVPECL and CML Compatible Inputs(Differential)
Vin
300
-
1600
mVpp
DC coupled inputs
Input Impedance (Differential)
Zin
85
100
115
ohm
Rin > 100 kohm @ DC
Tx ON / Burst Enable
VIH
2
Tx Off / Burst Disable
VIL
0
Tx ON / Burst Enable
VIL
0
Tx Off / Burst Disable
VIH
Burst Control
Vcc EOLS-GU-XXDB/K 0.8 V -
0.8 EOLS-GU-XXDA/J
2
-
Vcc
Receiver CML Outputs (Differential)
Vout
600
-
1000
mVpp
Output Impedance (Differential)
Zout
85
100
115
ohm
2
-
Vcc+0.3
V
0
-
0.8
V
Vcc+0.3
V
RX_SD
Normal SD
AC coupled outputs
2
I C Serial Logic I2C Serial Data I2C Serial Clock
SDA_H
2
-
SDA_L
0
-
0.8
V
SCL_H
2
-
Vcc+0.3
V
SCL_L
0
-
0.8
V
Performance Specifications – Optical Parameter
Symbol
Min.
Typical
Max.
Unit
Date Rate (Upstream/Downstream)
R
-
1.244/2488
-
Gbps
1280
1310
1360
nm
Transmitter Centre Wavelength
λC
-20dB Spectral Width
Δλ
-
-
1
nm
Side Mode Suppression Ratio
SMSR
30
-
-
dB
Average Output Power
Pout
0.5
-
5
dBm
ER
10
-
-
dB
-
0.15
0.26
ns
(Note4)
Extinction Ratio*
Rise/Fall Time (Optical, 10%~90%)
tR,tF
Output Optical Eye*(Note5)
ITU-T G984.2 Compliant
Optical Burst On/ Off Time
t_on/t_off
-
-
12.8
ns
Additive Jitter Generation
JA
-
-
0.2
UI
Eoptolink Technology Inc., Ltd. Page 3 of 8
V1.a
PON Series (Note3)
Optical Output Power with TX OFF*
P_off
-
-
-45
dBm
1480
1490
1500
nm
Receiver Centre Wavelength
λc
(Note6)
Receiver Sensitivity*
Pmin
-
-
-30
dBm
Saturation Optical Power
Pmax
-8
-
-
dBm
Damage Threshold
PDT
-
-
4
dBm
Receiver Reflectance
CR
-
-
-20
dB
0.5
Polarization Dependent Loss
PDL
-
-
LOS Assert
LOSA
-42
-
LOS De-Assert
LOSD
(Note7)
LOS Hysteresis*
0.5
dB dBm
-
-31
dBm
2
6
dB.
Note3: Measured with 9/125um G.652 SMF. 23
Note4: Filtered, measured with PRBS2 -1 test pattern @1.244Gbps. Note5: Eye Pattern Mask.
Note6: Measured with a PRBS 223 -1 test pattern @2.488Gbps and ER=10dB, BER 1X10-12. Note7: LOS Hysteresis(SD signal coincides with the LOS signal inversion)
Transmitter Burst Mode Timing Characteristics Eoptolink Technology Inc., Ltd. Page 4 of 8
V1.a
PON Series Power Supply Power supply
< 3V
Burst control
Data Input
Optical Output
X
X
OFF
>
Disable
X
OFF
Power supply 3.13V
Enable
NO
Other
Yes
Laser bias and modulation signal output
“X” means don’t care. “Other” means peak power less than +8dBm. “High/Low” means Logic high/low level. “No” means data not present, “Yes” means data present. “OFF” means the optical power less than -45dBm.
Burst transmitter timing
Enhanced Digital Diagnostic Interface The memory map in the following describes an extension to the memory map defined in SFF-8472 MSA. The enhanced interface uses the two wire serial bus address 1010001X (A2H) to provide diagnostic information about the module’s present operating conditions.
Eoptolink Technology Inc., Ltd. Page 5 of 8
V1.a
PON Series SFP Pin Function Definitions Pin No.
Pin Name
Description
1
VeeT
Tx Ground
2
Tx Fault
Indicate the TX fail.
Burst Control
LVTTL input. The default setting is that laser output is disable when this pin is asserted high and laser output is enabled when this pin is asserted low or laser output is disable when this pin is asserted low
3
(
and laser output is enabled when this pin is asserted high. BEN
)
4
MOD_DEF(2)
2-Wire Serial Data I/O Pin.(SDA)
5
MOD_DEF(1)
2-Wire Serial Clock Input.(SCL)
6
MOD_DEF(0)
Internally Grounded
7
TX_SD
Tx Transmitter State Indication, Assert high when Transmitter ON. Or to the ground directly if not use.
8
LOS/SD
Set LOS is that active high when signal is detected. (LVTTL); While the setting is SD,it active low when signal is detected. (LVTTL); Can be selected via specific part number.
9
NC
Not Connect
10
VeeR
Rx Ground
11
VeeR
Rx Ground
12
RXD-
13
RXD+
Non-Inverted Receiver Data Output (AC-Coupled internally)
14
VeeR
Rx Ground
15
Vcc_RX
Rx Vcc
16
Vcc_TX
Tx Vcc
17
Veet
Tx Ground
18
TXD+
Non-Inverted Transmitter Data Input (DC-Coupled)
19
TXD-
20
Veet
Tx Ground
F
Mounting Studs
Inverted Receiver Data Output (AC-Coupled internally)
Inverted Transmitter Data Input (DC-Coupled)
Eoptolink Technology Inc., Ltd. Page 6 of 8
V1.a
PON Series Recommend Circuit Schematic
Mechanical Specifications
SC Receptacle Eoptolink Technology Inc., Ltd. Page 7 of 8
V1.a
PON Series Laser Emission
Obtaining Document You can visit our website:http://www.eoptolink.com Or contact Eoptolink Technology Inc., Ltd. Listed at the end of the documentation to get the latest documents.
Revision History Revision
Initiated
Review
Approve
Description
Release Date
V1.a
Oliver
Lyn/Jason/ Nygai
Phlio
Released
Nov 19, 2015
Notice: Eoptolink reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. Eoptolink makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification.
Contact: Add: Floor 5, Building 2, No. 21 Gaopeng Avenue, High-Tech District, CHENGDU, SICHUAN 610041 P.R. CHINA Tel: (+86) 028-85122709 ext 816 & 809 Fax: (+86) 028-85121912 Postal: 610041 E-mail:
[email protected] http://www.eoptolink.com
Eoptolink Technology Inc., Ltd. Page 8 of 8
V1.a