Transcript
Engineering Safety & Productivity
Portable Power Solutions for Plant Turnarounds
Portable Power Solutions for Plant Turnarounds
Equipment Readiness Days Before Shutdown • Eliminate the risk of unsafe portable power equipment • No issues with limited power supplies
Current Situation
• No rush to install distribution centers and lighting during shutdown • No worries of equipment not working Improve safe control of power during turnarounds with equipment that is on-site, operational and ready-for-use.
Cooper Crouse-Hinds Solution
Install Equipment
Install Equipment (Power On)
Perform Maintenance
Perform Maintenance
Remove Equipment
Remove Equipment (Power On)
• No worries of contractor equipment not mating with outlets
Power Off
Cooper Crouse-Hinds’ Industrial and Hazardous Portable Power Platform utilizes our industryleading portfolio of NEC and IEC plugs and receptacles to provide custom solutions that improve the safety, time and control of power distribution for turnarounds.
Improve safety, time and control of power distribution for turnarounds with Cooper Crouse-Hinds as your partner
Maximize safe power readiness.
Current Situation • Risk of unsafe equipment installed or used in classified areas.
Portable Lighting
Portable Power Carts
Cable Assemblies and GFCI Devices
Cooper Crouse-Hinds market-leading luminaires are available in carts or stands, allowing for the set-up of your temporary lighting system within the hazardous area before shutdown.
Engineered and manufactured for NEC and IEC applications in hazardous or ordinary locations. Power carts are custom-built to each customer’s unique application and are available with a huge number of design features, including overload protection, forklift tubes, environmental protection, lifting eyes, locking wheels, lockout/tagout, and more.
Safe and reliable cable assemblies in a large variety of devices, sizes, amperages, and lengths. Available with our industry-leading NEC product brands including Arktite®, Ark•Gard®, Posi-Lok®, and CamLok®, as well as IEC configurations such as IEC 309 and Ex-Link®.
• Wasted time spent during shutdown moving and connecting portable power equipment. • Risk that equipment will not work or mate properly at start of maintenance (cannot be validated until shutdown occurs). • Wasted time spent unplugging and removing equipment before power is restored.
The Cooper Crouse-Hinds Solution • Install and validate products before power shutdown, allowing maintenance to begin immediately after power is turned off. • Issue safe and reliable cable assemblies to contractors upon arrival, eliminating lost productivity due to product mating errors and control power consumption in classified areas. • Safely restore plant operations before removing portable equipment.
2
3
Portable Power Solutions for Plant Turnarounds
2-Wheel
Power Carts
4-Wheel & Skid
A
B
Solutions designed for industrial and hazardous application
A Lifting Eyes
C Durable & Robust Carbon Steel Frame
C
E
Design Features
C
A Removable Roof
B Lifting Eyes
D Forklift Confinement Tubes E Enclosed Design Protects Components
F Enclosed Design Protects Components
E
C Durable & Robust Carbon Steel Frame
E
E Forklift Confinement Tubes
D
D
F Caster, Pneumatic, SemiPneumatic, or Solid Rubber Wheel Options
F
D
Technical Specs
Technical Specs Hazardous
Industrial Non-Hazardous
Specifications
Hazardous
Specifications
Primary Voltage: 240 – 600V Max Primary Current: 100A Max Secondary Voltage: 240V
Max Secondary Current: 225A Max Secondary Current w/ Main: 100A
Compatible Components Transformers 7.5 kVA 9 kVA 10 kVA 15 kVA 25 kVA
Panelboards EJB 12 circuit
Primary Voltage: 240 – 600V Max Primary Current: 100A Max Secondary Voltage: 480V
Disconnects EIB
Non-Hazardous
Receptacles CPS AR ENR WSQC CES WLRS FSQC WLRD Water tight Twist lock
Industrial Non-Hazardous
Specifications Max Secondary Current: 225A Max Secondary Current w/ Main: 225A
Compatible Components
Cart/Skid Sizes
Specifications
Primary Voltage: 240 – 600V Max Primary Current: 100A Max Secondary Voltage: 480V
Max Secondary Current: 225A Max Secondary Current w/ Main: 100A
Compatible Components Transformers 7.5 kVA 9 kVA 10 kVA 15 kVA 25 kVA
Panelboards 18 circuit 30 circuit Disconnects 30A, 60A, 100A
Receptacles CPS ENR CES FSQC CESD
Cart 1 Width: 28” Length: 14” Height: 58”
Primary Voltage: 240 – 600V Max Primary Current: 200A Max Secondary Voltage: 480V
Max Secondary Current: 225A Max Secondary Current w/ Main: 225A
Compatible Components Transformers 30 kVA 45 kVA
Disconnects EIB
Panelboards EPLBN 24 circuit EXDBN 24 circuit
Receptacles CPS AR ENR WSQC CES WLRS FSQC WLRD
Transformers 25 kVA 45 kVA 30 kVA 75 kVA
Disconnects 30A, 60A, 100A, 200A
Panelboards 18 circuit 30 circuit 42 circuit
Cart/Skid Sizes Hazardous
Hazardous Non-Hazardous
4
B
D Pneumatic, SemiPneumatic, or Solid Rubber Wheel Options
F
• UL/cUL 1640 compliant • 2-wheel, 4-wheel and skid options • Standardized cart sizes reduce lead times and eliminate potential on-site placement issues • Hazardous area power carts eliminate need for time-consuming area declassification and equipment monitoring
A C
B Power Cord Holder
Plant turnarounds can be complex, chaotic and costly events. During your next shutdown, turn to Cooper Crouse-Hinds for safe, reliable electrical power equipment that ensures efficient and successful operations.
Receptacles ENR CPS CES FSQC
B
A
Design Features
Cart 2 Width: 28” Length: 14” Height: 58”
Cart / Skid 1 Width: 30” Length: 40” Height: 58”
Non-Hazardous Cart / Skid 2 Width: 42” Length: 46” Height: 58”
Cart / Skid 3 Width: 40” Length: 62” Height: 58”
Cart / Skid 4 Width: 33” Length: 62” Height: 58”
5
Portable Power Solutions for Plant Turnarounds
Portable GFCI
Ark•Gard™ Series Portable ENR-GFCI Assemblies
Design Features • Provides hazardous location earth leakage protection to maximize safety of plant personnel
Portable ENR-GFCI Assemblies are used: • To interrupt a circuit when a ground fault is detected on portable equipment which may be handled by personnel in hazardous locations
• Solution to OSHA’s requirements for GFCI protection when using portable equipment in hazardous areas • LED indicator light provides indication that the receptacle is energized and ready for use
• With electrical equipment such as portable hazardous-rated hand lamps
• Available with either a red or green LED indicator light to provide indication that the receptacle is energized and ready for use
• Suitable for use in Class I Division 1 and 2 locations
Cable Assemblies
Design Features
Portable GFCI Cable Assemblies allow for:
• Improve Safety - earth leakage protection provides assurance that personnel and equipment are protected from ground fault hazards when performing maintenance
• Non-hazardous equipment connections with hazardous receptacles when areas have been declassified or hot work permits issued
• Increased Reliability construction meets Cooper Crouse-Hinds superior quality standards
• Earth leakage personnel protection when operating equipment such as drills, saws and hand lamps
• Increased Time Savings turn-key solution eliminates need for hazardous plugs to be installed on non-hazardous power tools • Increased Flexibility available with a variety of plug options to mate with a range of installed base of Cooper Crouse-Hinds receptacles
• Assemblies still consist of the same high quality components that make up the industry-leading Ark•Gard series
Ordering Information
Ordering Information Amp 20
6
Pilot Light
Portable ENR-GFCI Cat. #
Red LED
ENR22201 PGF1 RLED
Green LED
ENR22201 PGF1 GLED
Plug Style
Plug Pin Configuration
Plug Ratings
Group Trip Current
Cord Length
Cord Gauge
Cable Assembly Cat. #
ENP5201
NEMA 5-20
20 Amp 125 Volt
4-6 mA
2’
12/3 AWG
ENP5201 GFI
ENP5151
NEMA 5-20
15 Amp 125 Volt
4-6 mA
2’
12/3 AWG
ENP5151 GFI
CPP516
UL 1686 2W3P
20 Amp 125 Volt
4-6 mA
2’
12/3 AWG
CPP516 GFI
CPP516
UL 1686 2W3P
20 Amp 240 Volt
4-6 mA
2’
12/3 AWG
CPP516 GFI 240V
7
For more information: If further assistance is required, please contact an authorized Cooper Crouse-Hinds Distributor, Sales Office, or Customer Service Department.
U.S. (Global Headquarters): Cooper Crouse-Hinds Wolf & Seventh North Streets Syracuse, NY 13221 (866) 764-5454 FAX: (315) 477-5179 FAX Orders Only: (866) 653-0640
[email protected]
Canada: Cooper Crouse-Hinds Canada Toll Free: (800) 265-0502 FAX: (800) 263-9504 FAX Orders Only: (866) 653-0645
Mexico/Latin America/Caribbean: Cooper Crouse-Hinds, S.A. de C.V. 52-555-804-4000 FAX: 52-555-804-4020
[email protected]
Europe (Germany): Cooper Crouse-Hinds GmbH 49 (0) 6271 806-500 49 (0) 6271 806-476
[email protected]
Middle East (Dubai): Cooper Crouse-Hinds LLC 971 4 4272500 FAX: 971 4 4298521
Singapore: Cooper Crouse-Hinds Pte. Ltd. 65-6297-4849 FAX: 65-6297-4819
[email protected]
China: Cooper Crouse-Hinds Pte. Ltd. 86-21-2899-3600 FAX: 8-21-2899-4055
[email protected]
Korea: Cooper Crouse-Hinds Korea 82-2 3484-6783 82-2-3484-6778
[email protected]
Australia: Cooper Electrical Australia 61-2-8787-2777 FAX: 61-2-9609-2342
[email protected]
India: Cooper India Pvt. Ltd. 91-124-4683888 FAX: 91-124-4683899
[email protected]
www.crouse-hinds.com
Cooper Crouse-Hinds is a registered trademark of Cooper Industries, Inc. ©2012 Cooper Industries, Inc.
Your Authorized Cooper Crouse-Hinds Distributor is:
Cooper Industries, Ltd. 600 Travis, Ste. 5800 Houston, TX 77002-1001 P: 713-209-8400 www.cooperindustries.com
5033-0212
Printed in USA