Power Distribution System Svs04 Description

   EMBED


Share

Transcript

Power Distribution System SVS04 Description The SVS04 power distribution system for symmetrical DIN rail mounting is designed to distribute power from a switch-mode power supply to 4 or 8 channels. Selective protection of the load output circuits is provided by the plug-in type circuit breakers installed. With a max. load current of 8A per channel and a max. total current of 40A the SVS04 provides ease of wiring in short circuit current limited DC24V applications. Five protected “L+” load outputs per way and 15 or 30 minus terminals significantly reduce wiring time enormously. 1 Electronic circuit breaker ESS20-003, electronic circuit protector ESX10-103 and thermal-magnetic circuit breakers 2210-S21 are all suitable for use with the SVS04, plugging directly into the sockets provided for each of the 4 or 8 outputs. SVS04-08-... Ordering information Type SVS04 power distribution system for types ESS20-003, ESX10-103, 2210-S21 l for short circuit current limited DC 24 V applications l max. 40 A continuous load l one integral circuit breaker (CB1): overcurrent protection of group signalisation, red LED flashes upon trip of CB1 l including 1 insulated wire bridge Y 303 881 08 l accessories: jumper SB-S11-P1-01-1-1A for unused ways, please order separately Version, max. number of circuit breakers on the power distribution system 04 4 circuit breakers F1...F4) 08 8 circuit breakers (F1...F8) Fitted versions B10 standard: fitted with screwless spring-loaded terminals (max. 2.5 mm2, without wire end ferrule) B20 fitted with plug-in type screw terminals (max. 2.5 mm2, without wire end ferrule) C10 fitted with pcb terminals, spring-loaded terminals (max. 2.5 mm2, without wire end ferrule) Minus terminals ­ – 15 minus terminals K01 30 minus terminals (only for SVS04-08) Special marking SB01 with marked terminals entry line +++/-- remaining terminals 1/2/3/4/5 SVS04 - 04 - B10 - K01 - SB01 2015/16 Technical data DC 24 V supply DC 24 V terminals, 2x3 terminals (screwless terminals max. 10 mm2), for current supply - DC 24 V (+) = (X21) +/+/+ - DC 24 V (-) = (X21) -/-/- Integral loop-through, for wiring and additional connection of an external buffer module. F positions Number of ways for circuit breakers, suitable for types ESS20-003, ESX10-103, 2210-S21 SVS04-04... F1...F4 = terminals X1...X4 SVS04-08... F1...F8 = terminals X1...X8 Plug jumper SB-S11-P1-01-1-1A into unused ways (please order separately, see accessories) Load outputs 5 x L+ protected per position F1…F4 (F1…F8), led through terminals X1…X4 (X1…X8), max. 2.5 mm2 load current max. 8 A per position Signalisation signalisation terminal X31, 5-pole, max. 2.5 mm2 +: DC 24 V feed from terminal X21, protected by integral circuit breaker CB1 total current max. 0.5 A group signalisation: S: line feed DC 24 V, insert insulated wire bridge Y 303 881 08 (bulk shipped) between + and GR AS: output of group signalisation two-group signalisation GR: line feed, insert insulated wire bridge Y 303 881 08 (bulk shipped) between + and GR AS: output group A (X5…X8) B: output group B (X1…X4) Minus terminals 3 x 5 terminals (X22, X23, X24) or 6 x 5 terminals (X22, X23, X24, X25, X26, X27): version K01 Termination For signalisation, load outputs and minus terminals: B10: screwless spring-loaded terminals max. 2.5 mm2, with integral test socket B20: plug-in type screw terminals max 2.5 mm2, with integral test socket C10: pcb terminal/spring-loaded terminal max. 2.5 mm2, with integral test socket General data l protection class to DIN 40050: IP20 l insulation co-ordination to IEC 60934: 0.5 kV l pollution degree 2 l dielectric strength AC 500 V l temperature range: 0…50 °C (without condensation) l for symmetrical DIN rail mounting EN50022 – 35 x 7.5 l dimensions: see dimensional drawings www.e-t-a.de 1 - 59 Power Distribution System SVS04 Wiring example: SVS04-04… with ESS20-003 and group signalisation Signal path of group signalisation from F1 to F4 1 X31 AS B GR SC + X21 + -F1 * S X 31 AS + S SC / SO SC SC -F2 SO SC -F3 SO -F4 SO SO signalisation terminal signal output group signal +DC 24 V from terminal 21, internally prewired and protected by CB1 line feed group signalisation with insulation bridge* auxiliary contact ESS20-003, make contact Wiring example: SVS04-08... with ESS20-003 and group signalisation Signal path of group signalisation from F1 to F8 X31 AS B GR SC + X21 + * S X 31 AS + S SC / SO 1 - 60 -F1 SC -F2 SO SC -F3 SO SC -F4 SO SC -F5 SO SC -F6 SO SC -F7 SO SC -F8 SO SO signalisation terminal signal output group signal +DC 24 V from terminal 21, internally prewired and protected by CB1 line feed group signalisation with insulation bridge* auxiliary contact ESS20-003, make contact www.e-t-a.de 2015/16 Power Distribution System SVS04 Wiring example: SVS04-04… with ESS20-003 and two-group signalisation Signal path of two-group signalisation from F1 to F2 = group B, from F3 to F4 = group A 1 X31 AS B * + X21 group B = F1 ... F2 GR SC + SC -F1 S X31 AS B + GR SC/SO Gruppe A = F3 ... F4 SC -F2 SO SC -F3 SO -F4 SO SO signalisation terminal signal output group A (F3 ... F4) signal output group B (F1 ... F2) +DC 24 V from terminal 21, internally prewired and protected by CB1 line feed two-group signalisation with insulation bridge* auxiliary contact ESS20-003, make contact Wiring example: SVS04-08... with ESS20-003 and two-group signalisation Signal path of two-group signalisation from F1 to F4 = group B, from F5 to F8 = group A X31 AS B * + X21 2015/16 group A = F5 ... F8 GR SC + S X31 AS B + GR SC/SO group B = F1 ... F4 -F1 SC -F2 SO SC -F3 SO SC -F4 SO SC -F5 SO SC -F6 SO SC -F7 SO SC -F8 SO SO signalisation terminal signal output group A (F5 ... F8) signal output group B (F1 ... F4) +DC 24 V from terminal 21, internally prewired and protected by CB1 line feed two-group signalisation with insulation bridge* auxiliary contact ESS20-003, make contact www.e-t-a.de 1 - 61 Power Distribution System SVS04 Dimensions SVS04-04-... (with 15 minus terminals) 1 top hat rail EN 50022-35x7.5 (not supplied with product) 125,5 4.94 wire bridge, fully insulated 2-pole, not fitted, (1 piece enclosed) 52,2 2.06 red LED flashes when CBa1 trips depending on fitting version marked (X) X31 AS B GR Typ: SVS04-04 B10 B20 C10 + S X21 105,4 4.15 X22 RESET NUR KURZ DRÜCKEN DC24V/40A bridge, fully insulated, 3-pole F1 F2 F3 F4 X1 X2 X3 X4 X23 L+ L+ L+ L+ X24 L+ 15,5 .610 spacing load outputs, 5-pole 2.5 mm2 depending on fitting version screwless spring-loaded cage clamps B10 B20 plug-in type screw terminals C10 pcb cage clamps terminal power supply spring-loaded cage clamps 45° 10 mm2 Schematic diagram SVS04-04-… (fitted with ESS20-003) DC 24 V / max. 40 A X31 AS 1 B 2 GR 3 + 4 S 5 ESS20 ESS20 ESS20 ESS20 X22 1 Line (+) Line (+) Line (+) Line (+) GND (-) GND (-) GND (-) SC SC SC GND (-) SC SO SO SO SO LOAD (L+) LOAD (L+) LOAD (L+) LOAD (L+) F1 F2 F3 F4 2 3 + + 4 5 X23 1 + 2 - 3 4 - 5 - X21 CB1 R1 V1 V2 2 3 X1 1 X2 X3 X4 1 L+ 1 L+ 1 L+ 1 L+ 2 L+ 2 L+ 2 L+ 2 L+ 3 L+ 3 L+ 3 L+ 3 L+ 4 L+ 4 L+ 4 L+ 4 L+ 5 5 5 X24 1 2 3 4 5 5 LED V1 flashes upon trip of CB1 Circuit breaker CB1 shown in tripped condition 1 - 62 www.e-t-a.de 2015/16 Power Distribution System SVS04 Dimensions SVS04-04-..., fitted with ESS20-003 1 -003-DC24 V-1A/2A Elektronischer Schutzschalter Electronic Supplementary Protector 52.2 2.06 102 (105) 4.02 (4.13) fitted with ESS20- ... 105.4 4.15 top hat rail EN 50022-35x7.5 (not supplied with product) 125.5 4.94 red LED flashes when CB1 trips X31 AS B GR + S Typ: SVS04-04 B10 B20 C10 X21 X22 RESET NUR KURZ DRÜCKEN F1 F2 F3 F4 X1 X2 X3 X4 X23 DC24V/40A L+ L+ L+ L+ X24 L+ 15.5 .610 terminal power supply spring-loaded cage clamps 45° 10 mm2 spacing load outputs, 5-pole 2.5 mm2 depending on fitting version screwless spring-loaded cage clamps plug-in type screw terminals pcb cage clamps B10 B20 C10 This is a metric design and millimeter dimensions take precedence ( mm ) inch 2015/16 www.e-t-a.de 1 - 63 Power Distribution System SVS04 Dimensions SVS04-08-... (with 15 minus terminals) 1 wire bridge, fully insulated 2-pole, not fitted, (1 piece enclosed) top hat rail EN 50022-35x7.5 (not supplied with product) 187.5 7.38 red LED flashes when CB1 trips depending on fitting version marked (X) 52.2 2.06 - X31 AS B GR + S Typ: SVS04-08 B10 B20 C10 X21 X22 105.4 4.15 + + - RESET NUR KURZ DRÜCKEN DC24V/40A + bridge, fully insulated, 3-pole - F1 F2 F3 F4 F5 X1 X2 X3 X4 X5 F6 X6 F7 F8 X7 X8 L+ L+ L+ L+ L+ terminal power supply spring-loaded cage clamps 45° 10 mm2 X23 X24 15.5 .610 spacing load outputs, 5-pole 2.5 mm2 depending on fitting version screwless spring-loaded cage clamps B10 plug-in type screw terminals B20 pcb cage clamps C10 This is a metric design and millimeter dimensions take precedence ( mm ) inch 1 - 64 www.e-t-a.de 2015/16 Power Distribution System SVS04 Dimensions SVS04-08... K01 (with 30 minus terminals) 1 top hat rail EN 50022-35x7.5 (not supplied with product) 211.5 8.33 depending on fitting version marked (X) wire bridge, fully insulated 2-pole, not fitted, (1 piece enclosed) 52.2 2.06 red LED flashes when CB1 trips X22 X21 X23 X24 bridge, fully insulated, 3-pole RESET F1 NUR KURZ DRÜCKEN F2 DC24V/40A X1 X2 F3 X3 F4 F5 X4 X5 F6 F7 X6 X7 F8 4.15 Typ: SVS04-08-K01 B10 B20 C10 105.4 X31 AS B GR + S X25 X8 L+ L+ L+ L+ L+ X26 X27 15.5 terminal power supply .610 spring-loaded cage clamps spacing 45° 10 mm2 load outputs, 5-pole 2.5 mm2 depending on fitting version screwless spring-loaded cage clamps plug-in type screw terminals pcb cage clamps B10 B20 C10 Schematic diagram SVS04-08... K01 (fitted with ESS20-003) DC 24 V / max. 40 A X31 AS 1 B 2 GR 3 + 4 S 5 ESS20 ESS20 ESS20 ESS20 X22 Line (+) Line (+) GND (-) GND (-) SC SC SC Line (+) Line (+) GND (-) GND (-) SC SC SO SO SO SO LOAD (L+) LOAD (L+) LOAD (L+) LOAD (L+) F1 F2 F7 F8 + + F4 X25 1 1 2 2 3 3 4 4 5 5 X23 X26 1 1 + 2 2 - 3 3 4 4 5 5 - X21 CB1 R1 V1 V2 2 3 X1 1 1 X2 L+ 1 2 L+ 3 L+ L+ 4 4 5 X7 L+ 1 2 L+ 3 L+ L+ 4 5 X8 L+ 1 2 L+ 2 L+ 3 L+ 3 L+ L+ 4 5 L+ L+ X24 X27 1 1 2 2 3 3 4 4 5 5 5 LED V1 flashes upon trip of CB Circuit breaker CB1 shown in tripped condition 2015/16 www.e-t-a.de 1 - 65 Power Distribution System SVS04 Dimensions SVS04-08... K01, fitted with ESX10-103 1 52.2 2.06 70 2.76 fitted with ESX10- ... 105.4 4.15 top hat rail EN 50022-35x7.5 (not supplied with product) wire bridge, fully insulated 2-pole, not fitted, (1 piece enclosed) 211.5 8.33 depending on fitting version marked (X) red LED flashes when CB1 trips X31 AS B GR + S Typ: SVS04-08-K01 B10 B20 C10 X22 X21 X23 X24 bridge, fully insulated, 3-pole RESET NUR KURZ DRÜCKEN F1 DC24V/40A X1 F2 X2 L+ L+ L+ L+ L+ terminal power supply spring-loaded cage clamps 45° 10mm2 F3 X3 F4 X4 F5 X5 F6 X6 F7 X7 F8 X25 X8 X26 X27 15.5 .610 spacing load outputs, 5-pole 2.5 mm2 depending on fitting version screwless spring-loaded cage clamps plug-in type screw terminals pcb cage clamps B10 B20 C10 This is a metric design and millimeter dimensions take precedence ( mm ) inch 1 - 66 www.e-t-a.de 2015/16 Power Distribution System SVS04 Accessories Application example for jumper to replace The signalling pathway of the group signalisation is as follows: - feed-in of +DC 24 V potential in X31 (»+« terminal) via in-built overcurrent protection CB1 - via all signal contacts of the fitted circuit breakers type ESS20-003 - back to signal output of group signalisation X31 (»AS«) Jumper SB-S11-P1-01-1-1A top view Germany Signalbrücke Signal loop SB-S11-P1-01-1-1A In operating condition (i.e. all circuit breakers plugged in and functional) the signalling pathway X31 from »+« to »AS« is closed. 1 If the distribution rail is not completely fitted with ESS20-003, the open pathway »+« to »AS« may be closed by means of a jumper type SB-S11-P1-01-1-1A 70 2.76 X21 RESET NUR KURZ DRÜCKEN F1 F2 F3 F4 X1 X2 X3 X4 2 14 12.3 .484 10.3 .406 Signalbrücke Signal loop + S 1 Typ: SVS04-04 B10 B20 C10 13 AC 240 V / DC 65 V, 1 A X31 AS B GR 60 2.36 xxxx Signalbrücke Signal loop www.e-t-a.de X22 terminals 13+14 bridged X23 blade terminals DIN 46244-A 6.3-0.8 DC24V/40A L+ L+ L+ L+ X24 L+ Insulated wire bridge Y 303 881 08 1 piece of the insulated wire bridge are supplied with the power distribution system. The insulated wire bridges may be used for: Application example for insulated wire bridge Terminal X31 (group signalisation) wire bridge from (+) to (SC) internal +DC24V feed for signalisation Thus plus potential of terminal X21+ is connected to (S) - terminal X31: internal DC 24 V feed for group signalisation wire bridge from (+) to (S) signal path protected by CB1 - terminal X31: internal DC 24 V feed for two-group signalisation wire bridge from (+) to (GR) signal path protected by CB1 X31 AS B GR + S Typ: SVS04-04 B10 B20 C10 X21 X22 RESET NUR KURZ DRÜCKEN F1 F2 F3 F4 X1 X2 X3 X4 X23 DC24V/40A L+ L+ L+ L+ L+ X24 This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 2015/16 www.e-t-a.de 1 - 67 1 1 - 68 www.e-t-a.de 2015/16