Preview only show first 10 pages with watermark. For full document please download

Power Over Ethernet Adapter Psa16u Universal Input

   EMBED


Share

Transcript

WWW.PHIHONG.COM Power Over Ethernet Adapter PSA16U Universal Input Features ! Fully Compliant with IEEE802.3af ! Legacy detection Optional ! Non-Vented Case ! IOL Test report Applications ! IP Telephones ! Wireless Network Access Points ! Blue Tooth Access Point AC Disconnect Optional Data and Power carried over one Ethernet cable ! Diagnostic Leds ! ! ! ! Safety Approvals ! cUL/UL60950 3rd Edition ! CE ! Security Camera IP Print Servers TUV EN60950 Mechanical Characteristics Dimensions: ! Length: 140mm (5.51in) ! Width: 65mm (2.55in) ! ! Height: 36mm (1.42in) Weight: 0.2Kg (0.44Ib) Output Specifications Model PSA16U-480(POE) Ripple and Noise* <500Hz 500Hz-150Khz 150KHz-500KHz 500KHz-1MHz DC Output Voltage 48V Vp-p* 0.5 0.15 0.15 0.1 Load Min. 0A Regulation Max. 0.35A Line +3% Load +3% *As per IEEE802.3af Table 33-5 For Legacy detection or AC disconnect please contact the factory. Phihong is not responsible for any errors or changes. Please contact the factory and visit www.phihong.com for the most up-to-date specifications. WWW.PHIHONG.COM PSA16U Characteristics ENVIRONMENTAL: Operation Temperature 0 to 40oC Non-Operation Temperature -25 to +65oC Humidity 5 to +90% (Operation) Emissions FCC Part 15 Class B, Shielded FTP CAT5 EN 55022 Class B Immunity EN61000-4-2: Level 3 ESD EN61000-4-3: Level 2 RS EN61000-4-4: Level 2 FET/Burst EN61000-4-5: (L-N) Level 3 Surge (L-G) Level 3 EN61000-4-6: Level 2 CS EN61000-4-11Voltage Dip, Short Interruption and Voltage Variation Immunity EN61000-3-2 Harmonic Dielectric Withstand (Hipot) Test Primary to secondary: 3000VAC 1 minute 10mA or 1 second 10mA Primary to F.G.: 1500VAC for 1 minute 10mA Insulation Resistance Primary to secondary: >10M OHM 500VDC Primary to FC: >10M OHM 500VDC ADAPTER INPUT: AC Input Voltage Rating 100 to 240 VAC AC Input Voltage Range 90 to 264 VAC AC Input Frequency 47 to 63Hz Leakage Current 0.25mA Max. for 254VAC 60Hz Max. Inrush Current 15A for 115VAC at Max. Load 20A for 230VAC at Max. Load OUTPUT: Efficiency 75% typical at Max. load and 120VAC 60Hz Maximum Output Power 15.4W Hold-up Time 16mS Min. at Max. load and 120VAC 60Hz Transient O/P Voltage Protection 60V Max. at switch on and off at any AC line Phase Overvoltage and Overcurrent Protection Overload and Short Circuit Protect per IEEE802.3af Dimension Diagram Unit: mm (inch) PSA16U/0408