Transcript
EMP/HEMP/IEMI FILTER SOLUTIONS
POWER PROTECTION FILTERS
THE SUREST SOLUTION BY ANY MEASURE™
ets-lindgren.com
PRODUCT INFORMATION
Ideal Protection for Demanding Environments ETS-Lindgren EMP/HEMP power line filters offer excellent multi-stage over-voltage and EMI/RFI protection. These single unit filters are available in either two or four individually filtered lines, with ratings of 227/480 VAC, 30 A to 400 A. These EMP/HEMP series filters are available in the following configurations: • Individual, Stand-alone Single Circuit Filters • “Twin” Dual Circuit Filters for Single Phase Installations • Multiple Line Panel Filters for Facility Installations -- Single Phase -- Three Phase
All EMP/HEMP filters meet or exceed the following performance and safety criteria: • MIL-STD-188-125-1 & -2 • MIL-F-15733 • MIL-STD-220C • UL 1283 • IEC 60939 • LVD (2006/95/EC)
ETS-Lindgren is ISO 9001:2008 registered through DNV for fabrication of antennas, absorbers, shielding, shielded doors and other system components. We maintain a continuous Quality Assurance program and solicit feedback on quality and product performance.
BEIJING CEDAR PARK EURA STEVENAGE TAUFKIRCHEN
Designed to Meet Point-of-Entry Requirements of MIL-STD-188-125-1 & -2 for Short and Intermediate Pulses in Addition to High Insertion Loss Performance for SCIF, TEMPEST and Other Military and Commercial Applications High Frequency Response Design Our filters use a high frequency feed-through capacitor design, which provides better high frequency response.
Reliable Transient Suppression Elements
Pulse Current Our filters are fitted with high transient suppressors in front of the inductive input circuit. This feature results in very low residual currents during an EMP pulse, protecting the connected equipment.
Our filters use suppression elements. These elements protect both the filter and the connected equipment by absorbing and diverting power to ground.
Wide Selection of Current Ratings
Superior Insertion Loss Performance
Custom Designs Available
Our filters perform at 100 dB from 14 kHz to 40 GHz at full load. This provides better EMI, RFI, HIRF and IEMI attenuation performance.
Extended Filter Life Our filters use oversized inductors for low loss and low temperature rise, resulting in extended filter life. Filter life is further extended by incorporating self-healing capacitors.
These filters are available in configurations of 30 A, 60 A, 100 A, 250 A and 400 A at 277/480 VAC.
Need something special? ETS-Lindgren can custom design a filter specific to your exact needs. Please contact the ETS-Lindgren Sales Department for further details.
PRODUCT SPECIFICATIONS
EMP, HEMP and IEMI Power Line Filters Product Specifications RATINGS AND CHARACTERISTICS RATED VOLTAGE
TEST VOLTAGE
INSULATION RESISTANCE
DISCHARGE RESISTORS
DISCHARGE TIME
MAX. TEMP. RISE ON FULL LOAD
FULL LOAD OPERATING TEMP. RANGE
LEAKAGE CURRENT AT 250 VAC 50 HZ
PEAK SURGE CURRENT
0 - 277/480 RATEDVAC 50/60 Hz VOLTAGE
2250 VDC Each Line TEST toVOLTAGE Case per
> 100 MΩ INSULATION (Prior to Fitting RESISTANCE
Fitted Internally from DISCHARGE Each Line to Case RESISTORS
< 30 sec. DISCHARGE TIME
-25 CLOAD to FULL 65o C OPERATING TEMP. RANGE
100 MΩ (Prior to Fitting
Fitted Internally from Each Line to Case
< 30 sec.
25o C
-25o C to 65o C
< 10% of Rated Current
70 kA (8/µs)
RATINGS AND CHARACTERISTICS UL 1283 and LVD
UL 1283 and LVD
(Prior to Fitting Transient Suppressors)
INSERTION LOSS PERFORMANCE* Minimum Loss in 50 Ω system with/without load
FREQUENCY
INSERTION LOSS
INSERTION LOSS PERFORMANCE* kHz in 50 Ω system with/without 100load dB Minimum14Loss 1 MHz FREQUENCY
100 dB LOSS INSERTION
1014MHz kHz
100 100dB dB
100 MHz 1 MHz
100 100dB dB
1 GHz 10 MHz
100 100dB dB
10 GHz 100 MHz
100 100dB dB
401 GHz GHz
100 100dB dB
*Both Symmetric and Asymmetric
10 GHz
100 dB
40 GHz
100 dB
Discharge Resistors)
Discharge Resistors)
PULSE SUPPRESSION PERFORMANCE
MIL-STD-188-125-1 acceptance test, short pulse current injection, wave-shape 20/500 ns
INPUT PULSE
MIL-STD-188-125 RESIDUAL REQUIREMENT
AMPLITUDE ANDPERFORMANCE FILTER RESIDUAL LET THROUGH PULSE SUPPRESSION
MIL-STD-188-125-1 acceptance test, short pulse current injection, wave-shape 20/500 ns
250 A
< 10 A
o
o
SURGE CURRENT
PULSE SUPPRESSION PERFORMANCE
MIL-STD-188-125-1 acceptance test, intermediate pulse current injection, wave-shape 1.5/300 ns
INPUT PULSE
MIL-STD-188-125
PULSE SUPPRESSIONREQUIREMENT PERFORMANCE AMPLITUDE
TYPICAL FILTER RESPONSE
MIL-STD-188-125-1 acceptance test, intermediate pulse current injection, wave-shape 1.5/300 ns
250 A
INPUT PULSE 500 A AMPLITUDE
MIL-STD-188-125 RESIDUAL REQUIREMENT < 10 A LET THROUGH AND FILTER RESIDUAL
INPUT PULSE AMPLITUDE
1000 250 AA
<< 10 10AA
250 A
1800 500 AA
<< 10 10AA
2500 1000AA
<< 10 10AA
1800 A
< 10 A
2500 A
< 10 A
No Filter Damage or Performance Degradation MIL-STD-188-125
No Filter Damage Performance TYPICALDegradation FILTER
No Filter Damage or Performance Degradation
No Filter Damage Performance Degradation
REQUIREMENT
*Both Symmetric and Asymmetric
14 kHz Insertion Loss Performance Range
RESPONSE
CONFIGURATIONS
Individual EMP/HEMP Power Line Filters: LRX-EMP Series The LRX-EMP series of filters is available for individual mounting requirements. These filters are supplied in two case styles. The Style 2 (designated as S2) case configuration is designed for direct installation on a shielded room. The Style 3 (designated as S3) case configuration is designed for installation within a shielded filter panel. Style 3 filters can be supplied as individual replacement filters for installation within the LPRX-EMP and LFPRXEMP filter panels.
LRX-EMP Filter - Style 2
LRX-EMP Filter - Style 3 A+X
0.75" TYP
A
B
B (5-100 AMP) C (150-400 AMP)
1.50" TYP
1.00" TYP
SECURITY COVER
SCREW COVER C B (5-100 AMP) C (150-400 AMP)
THREADED PENETRATION LRX 5-30 AMP, ADD 6.5" TO A LRX 50-100 AMP, ADD 8.5" TO A LRX 125-225 AMP, ADD 12.5" TO A LRX 250-400 AMP, ADD 11.25" TO A
VALUES TO ADD FOR X
LRX-EMP FILTER (100 dB, 14 kHz to 40 GHz)
Style 2
Style 3
MODEL NUMBER
CURRENT RATING
HEIGHT “A”
LRX-1030-EMP-*
30 A
64.8 cm (25.5 in.)
LRX-1060-EMP-*
60 A
LRX-1100-EMP-* LRX-1250-EMP-* LRX-1400-EMP-*
CASE DIMENSIONS WIDTH “B”
DEPTH “C”
APPROX. WEIGHT
11.4 cm (4.5 in.)
11.4 cm (4.5 in.)
10.4 kg (23 lbs.)
85.1 cm (33.5 in.)
15.2 cm (6 in.)
17.8 cm (7 in.)
18.1 kg (40 lbs.)
100 A
85.1 cm (33.5 in.)
15.2 cm (6 in.)
17.8 cm (7 in.)
20.4 kg (45 lbs.)
250 A
95.3 cm (37.5 in.)
20.3 cm (8 in.)
25.4 cm (10 in.)
45.4 kg (100 lbs.)
400 A
103.6 cm (40.8 in.)
20.3 cm (8 in.)
30.5 cm (12 in.)
54.4 kg (120 lbs.)
* Please specify either S2 (Style 2) or S3 (Style 3) configuration.
“Twin” Dual Circuit EMP/HEMP Power Line Filters: LRX-EMP Series “Twin” dual circuit power line filters are designed for wall-mounted installation, and use on AC or DC power lines. These filters can be used for either two-wire AC systems with both lines above ground or three-wire AC systems where one of the conductors is at ground potential and grounded to the filter case.
POWER INPUT
LOAD
2X RATED CURRENT
FILTER CASE GROUND
Dual Circuit Power Line Filter
A
B
LRX-EMP TWIN FILTER (100 dB, 14 kHz to 40 GHz) MODEL NUMBER
CURRENT RATING
LRX-2030-EMP
2 x 30 A
94.0 cm
(37 in.)
LRX-2060-EMP
2 x 60 A
LRX-2100-EMP
CL
1.00" TYP
SECURITY COVER
DEPTH “C”
APPROX. WEIGHT
22.9 cm (9 in.)
12.7 cm (5 in.)
31.8 kg (70 lbs.)
111.8 cm (44 in.)
35.6 cm (14 in.)
15.2 cm (6 in.)
36.3 kg (80 lbs.)
2 x 100 A
111.8 cm (44 in.)
35.6 cm (14 in.)
15.2 cm (6 in.)
45.4 kg (100 lbs.)
LRX-2250-EMP
2 x 250 A
121.9 cm (48 in.)
35.6 cm (14 in.)
15.2 cm (6 in.)
68.0 kg (150 lbs.)
LRX-2400-EMP
2 x 400 A
132.1 cm (52 in.)
61.0 cm (24 in.)
22.9 cm (9 in.)
90.7 kg (200 lbs.)
HEIGHT “A”
#0.260 MOUNTING HOLE
CASE DIMENSIONS WIDTH “B”
SCREW COVER
C
THREADED PENETRATION 1. GROUNDING STUD PROVIDED INSIDE INPUT AND OUTPUT WIRING COMPARTMENTS. 2. ADDITIONAL MOUNTING HOLES PROVIDED IN MOUNTING FLANGE ON 3 AND 4 LINE FILTERS.
Multiple Line EMP/HEMP Filters in Panels: LPRX-EMP & LFPRX-EMP Series The LPRX-EMP AND LFPRX-EMP series filters are available in NEMA 1 type panels for wall-mounted and floor-standing installations. These panels incorporate an EM/RFI tight compartment (security well) that meets the highest performance criteria: a full 100 dB shielding effectiveness from 14 kHz to 40 GHz.
LPRX -EMP Wall Panels
LPRX-EMP FILTER (Wall Mounted, 100 dB, 14 kHz to 40 GHz) B
A
2.00
C
1/4" THK MNTG BRKT, w/1/2" DIA. HOLE THRU (4 PL)
LFPRX-EMP Floor Panels
MODEL NUMBER
CURRENT RATING
CASE DIMENSIONS WIDTH “B”
DEPTH “C”
APPROX. WEIGHT
LPRX-2x30-EMP
2 x 30 A
91.4 cm
(36 in.)
30.5 cm (12 in.)
15.2 cm (6 in.)
36.3 kg (80 lbs.)
LPRX-3x30-EMP
3 x 30 A
91.4 cm
(36 in.)
61.0 cm (24 in.)
15.2 cm (6 in.)
49.9 kg (110 lbs.)
LPRX-4x30-EMP
4 x 30 A
91.4 cm
(36 in.)
61.0 cm (24 in.)
15.2 cm (6 in.)
63.5 kg (140 lbs.)
LPRX-2x60-EMP
2 x 60 A
121.9 cm (48 in.)
40.6 cm (16 in.)
21.6 cm (8.5 in.)
63.5 kg (140 lbs.)
LPRX-3x60-EMP
3 x 60 A
121.9 cm (48 in.)
76.2 cm (30 in.)
21.6 cm (8.5 in.)
90.7 kg (200 lbs.)
LPRX-4x60-EMP
4 x 60 A
121.9 cm (48 in.)
76.2 cm (30 in.)
21.6 cm (8.5 in.)
117.9 kg (260 lbs.)
LPRX-2x100-EMP
2 x 100 A
121.9 cm (48 in.)
40.6 cm (16 in.)
21.6 cm (8.5 in.)
68.0 kg (150 lbs.)
LPRX-3x100-EMP
3 x 100 A
121.9 cm (48 in.)
76.2 cm (30 in.)
21.6 cm (8.5 in.)
97.5 kg (215 lbs.)
LPRX-4x100-EMP
4 x 100 A
121.9 cm (48 in.)
76.2 cm (30 in.)
21.6 cm (8.5 in.)
81.6 kg (180 lbs.)
CASE DIMENSIONS WIDTH “B”
DEPTH “C”
APPROX. WEIGHT
LPRX -EMP Wall Panels
B
LFPRX-EMP FILTER (Floor Mounted, 100 dB, 14 kHz to 40 GHz)
C
MODEL NUMBER
A
A
B
CURRENT RATING
HEIGHT “A”
LFPRX-2x250-EMP
2 x 250 A
188.0 cm (74 in.)
50.8 cm (20 in.)
35.6 cm (14 in.)
163.3 kg (360 lbs.)
LFPRX-3x250-EMP
3 x 250 A
188.0 cm (74 in.)
99.1 cm (39 in.)
35.6 cm (14 in.)
231.3 kg (510 lbs.)
LFPRX-4x250-EMP
4 x 250 A
188.0 cm (74 in.)
99.1 cm (39 in.)
35.6 cm (14 in.)
299.4 kg (660 lbs.)
LFPRX-2x400-EMP
2 x 400 A
188.0 cm (74 in.)
50.8 cm (20 in.)
35.6 cm (14 in.)
172.4 kg (380 lbs.)
188.0 cm (74 in.)
99.1 cm (39 in.)
35.6 cm (14 in.)
244.9 kg (540 lbs.)
188.0 cm (74 in.)
99.1 cm (39 in.)
35.6 cm (14 in.)
317.5 kg (700 lbs.)
LFPRX-3x400-EMP 12.0
HEIGHT “A”
LFPRX-4x400-EMP
3 x 400 A 2.00
4 x 400 A
1/4" THK MNTG BRKT, w/1/2" DIA. HOLE THRU (4 PL)
C
ADDENDUM
ETS-LINDGREN EMI/RFI//EMP/HEMP/IEMI Filters In addition to our posted catalog and in keeping with ETS-Lindgren’s policy of continued improvement, ETS-Lindgren now offers additional Power and Signal Filters for its EMP/HEMP/IEMI line. EMP/HEMP/IEMI POWER FILTERS ETS-Lindgren now offers power filters for the mitigation and elimination of EMP/HEMP/IEMI pulses according to MILSTD- 188-125. Specifically, these filters pass the E1 requirements for residual currents below 10 Amps and also pass the no-damage requirements of the E2 pulse of MIL-STD-188-125. These filters also offer high performance EMI/RFI protection for military, TEMPEST, and commercial applications per MIL-STD-220. All power filters are rated for voltages up to 277/480 VAC at 50/60 Hz. Current Rating
Case Dimension: Height "A"
Case Dimension: Width "B"
Case Dimension: Depth "C"
Approx. Weight
LRX-1010-EMP-S2
10A
64.8 cm (25.5 in.)
11.4 cm (4.5 in.)
11.4 cm (4.5 in.)
10.4 Kg (23 lbs.)
LRX-1010-EMP-S3
10A
64.8 cm (25.5 in.)
11.4 cm (4.5 in.)
11.4 cm (4.5 in.)
10.4 Kg (23 lbs.)
2x10A
94.0 cm (37 in.)
22.89 cm (9 in.)
12.7 cm (5 in.)
31.8 Kg (70 lbs.)
Model Number
LRX-2010-EMP LPRX-2x10-EMP
2x10A
91.4 cm (36 in.)
30.5 cm (12 in.)
15.2 cm (6 in.)
36.3 Kg (80 lbs.)
LPRX-3x10-EMP
3x10A
91.4 cm (36 in.)
61.0 cm (24 in.)
15.2 cm (6 in.)
52.3 Kg (115 lbs.)
LPRX-4x10-EMP
4x10A
91.4 cm (36 in.)
61.0 cm (24 in.)
15.2 cm (6 in.)
63.5 Kg (140 lbs.)
Current Rating
Case Dimension: Height "A"
Case Dimension: Width "B"
Case Dimension: Depth "C"
Approx. Weight
600A
134 cm (52.7 in.)
25.4 cm (10 in.)
40.6 cm (16 in.)
113.6 Kg (250 lbs.)
Model Number LRX-1600-EMP-S3 LPRX-2x600-EMP
TBA
TBA
TBA
TBA
LPRX-3x600-EMP
3x600A
2x600A
208.3 cm (82 in.)
119.4 cm (47 in.)
45.7 cm (18 in.)
568.2 Kg (1250 lbs.)
LPRX-4x600-EMP
4x600A
208.3 cm (82 in.)
119.4 cm (47 in.)
45.7 cm (18 in.)
681.8 Kg (1500 lbs.)
LFPRX when floor mounting needed.
Model Number
Current Rating
Case Dimension: Height "A"
Case Dimension: Width "B"
Case Dimension: Depth "C"
Approx. Weight 159.1 Kg (350 lbs.)
LRX-1800-EMP-S3
800A
116.8 cm (46 in.)
55.9 cm (22 in.)
25.4 cm (10 in.)
LPRX-2x800-EMP
2x800A
TBA
TBA
TBA
TBA
LPRX-3x800-EMP
3x800A
238.8 cm (94 in.)
236.2 cm (93 in.)
35.6 cm (14 in.)
840.9 Kg (1850 lbs.)
LPRX-4x800-EMP
4x800A
238.8 cm (94 in.)
236.2 cm (93 in.)
35.6 cm (14 in.)
1000 Kg (2200 lbs.)
Current Rating
Case Dimension: Height "A"
Case Dimension: Width "B"
Case Dimension: Depth "C"
Approx. Weight
LRX-11250-EMP-S3
1250A
182.9 cm (72 in.)
55.9 cm (22 in.)
33 cm (13 in.)
454.5 Kg (1000 lbs.)
LPRX-2x1250-EMP
2x1250A
TBA
TBA
TBA
TBA
LPRX-3x1250-EMP
3x1250A 274.3 cm (108 in.)
177.8 cm (70 in.)
40.6 cm (16 in.)
1500 Kg (3300 lbs.)
LPRX-4x1250-EMP
4x1250A 304.8 cm (120 in.)
256.5 cm (101 in.)
50.8 cm (20 in.)
2000 Kg (4400 lbs.)
Model Number
Current Rating
Case Dimension: Height "A"
Case Dimension: Width "B"
Case Dimension: Depth "C"
Approx. Weight
LPRX-1x3600-EMP*
3600A
274.3 cm (108 in.)
177.8 cm (70 in.)
40.6 cm (16 in.)
1500 kg. (3300 lbs.)
Model Number
* Four units required for a 3 phase plus Neutral system.
EMP/HEMP/IEMI SIGNAL FILTERS ETS-Lindgren has also expanded the offering of signal filters for the mitigation and elimination of EMP/HEMP/IEMI pulses according to MIL-STD-188-125. Specifically, these filters pass the E1 requirements for residual currents and also pass the nodamage requirements of the E2 pulse of MIL-STD-188-125. The signal filters offer the appropriate passband to allow desired signals to pass though without degradation, but also offer high performance EMI/RFI protection for military, TEMPEST, and commercial applications per MIL-STD-220. PHONE (POTS) FILTERS
TYPE: (-600ZLV) Passband Loss
Stopband Insertion Loss
600(L-L)
1.0 dB max
100 dB min @
300(L-G)
0 - 5 kHz
Passband Impedance
Model
14 kHz to 18 GHz
Max Current
Max Voltage
0.5 A
90 V
No. of Wires
Width
LTC-2640-EMP-600ZLV
2
3.00"
Weight 5 lbs.
LTC-4640-EMP-600ZLV
4
6.00"
10 lbs. 15 lbs.
LTC-6640-EMP-600ZLV
6
12.00"
LTC-8640-EMP-600ZLV
8
12.00"
20 lbs.
LTC-10640-EMP-600ZLV
10
18.00"
25 lbs.
LTC-12640-EMP-600ZLV LTC-2650-EMP-600ZLV
12
18.00"
30 lbs. 3 lbs.
2
MULTIPLE LINE CASE DIMENSIONS
PHONE (POTS) FILTERS
TYPE: (-600ZHV) Passband Loss
Stopband Insertion Loss
600(L-L)
1.0 dB max
100 dB min @
300(L-G)
0 - 5 kHz
Passband Impedance
Model
14 kHz to 18 GHz
Max Current
Max Voltage
0.5 A
250 V
No. of Wires
Width
LTC-2640-EMP-600ZLV
2
3.00"
Weight 5 lbs.
LTC-4640-EMP-600ZLV
4
6.00"
10 lbs. 15 lbs.
LTC-6640-EMP-600ZLV
6
12.00"
LTC-8640-EMP-600ZLV
8
12.00"
20 lbs.
LTC-10640-EMP-600ZLV
10
18.00"
25 lbs.
LTC-12640-EMP-600ZLV LTC-2650-EMP-600ZLV
12
18.00"
30 lbs. 3 lbs.
2
LTC-2650-EMP-XXXX CASE DIMENSIONS
CONTROL FILTERS
TO BE USED IN CABINET/PANEL FILTERS
TYPE: (-2053LV)
Passband Impedance 40(L-L) 20(L-G)
Passband Loss 1.0 dB max 0 - 1 kHz
Model
No. of Wires
Stopband Insertion Loss 100 dB min @ 14 kHz to 18 GHz Width
Max Current
Max Voltage
3A
75 V
TYPE: (-140Z)
2
3.00"
5 lbs.
LTC-4640-EMP-2053LV
4
6.00"
10 lbs.
LTC-6640-EMP-2053LV
6
12.00"
15 lbs.
LTC-8640-EMP-2053LV
8
12.00"
20 lbs.
LTC-10640-EMP-2053LV
10
18.00"
25 lbs.
LTC-12640-EMP-2053LV
12
18.00"
30 lbs.
LTC-2650-EMP-2053LV
2
3 lbs.
TYPE: (-2053HV) Passband Loss
40(L-L)
1.0 dB max
20(L-G)
0 - 1 kHz Model
Loss 100 dB min @
14 kHz to 18 GHz
Max Current
Max Voltage
3A
250 V
Width
LTC-2640-EMP-2053HV
2
3.00"
5 lbs.
LTC-4640-EMP-2053HV
4
6.00"
10 lbs.
LTC-6640-EMP-2053HV
6
12.00"
15 lbs.
LTC-8640-EMP-2053HV
8
12.00"
20 lbs.
Weight
LTC-10640-EMP-2053HV
10
18.00"
25 lbs.
LTC-12640-EMP-2053HV
12
18.00"
30 lbs.
2
Stopband Insertion Loss 100 dB min @
70(L-G)
0 - 4 kHz
100 kHz to 18 GHz
Passband Loss
3 lbs.
Max Current
Max Voltage
0.5 A
75 V
No. of Wires
Width
LTC-2640-EMP-140Z
2
3.00"
5 lbs.
LTC-4640-EMP-140Z
4
6.00"
10 lbs.
LTC-6640-EMP-140Z
6
12.00"
15 lbs.
LTC-8640-EMP-140Z
8
12.00"
20 lbs.
LTC-10640-EMP-140Z
10
18.00"
25 lbs.
LTC-12640-EMP-140Z
12
18.00"
30 lbs.
LTC-2650-EMP-140Z
No. of Wires
LTC-2650-EMP-2053LV
1.0 dB max
Model
CONTROL FILTERS (High Voltage)
Passband Impedance
140(L-L)
Passband Impedance
Weight
LTC-2640-EMP-2053LV
Stopband Insertion
AUDIO FILTERS
2
Weight
3 lbs.
PUBLIC ADDRESS (PA) SYSTEM FILTERS TYPE: (-5000Z) Passband Impedance
5000(L-L) 2500(L-G) Model
Passband Loss
Stopband Insertion
Max Current
Max Voltage
1.0 dB max 0 - 4 kHz
100 dB min @ 100 kHz to 18 GHz
0.025 A
70 V
Weight
Loss
No. of Wires
Width
LTC-2640-EMP-5000Z
2
3.00"
5 lbs.
LTC-4640-EMP-5000Z
4
6.00"
10 lbs.
LTC-6640-EMP-5000Z
6
12.00"
15 lbs.
LTC-8640-EMP-5000Z
8
12.00"
20 lbs.
LTC-10640-EMP-5000Z
10
18.00"
25 lbs.
LTC-12640-EMP-5000Z
12
18.00"
30 lbs.
LTC-2650-EMP-5000Z
2
3 lbs.
ADDENDUM
DATA FILTERS (9.6 kbps rate) TYPE:FILTERS (-C10K)(9.6 kbps rate) DATA TYPE: (-C10K) Passband Impedance
High Voltage
Stopband Insertion Loss
Passband Loss
600(L-L) 300(L-G)
0.5 dB max 0 - 25 kHz Model
Max Current
Max Voltage
0.5 A
220 V
100 dB min @ 100 kHz to 18 GHz
No. of Wires
Width
Weight
2 4 6 8 10 12 2
3.00" 6.00" 12.00" 12.00" 18.00" 18.00"
5 lbs. 10 lbs. 15 lbs. 20 lbs. 25 lbs. 30 lbs. 3 lbs.
LTC-2640-EMP-C10K LTC-4640-EMP-C10K LTC-6640-EMP-C10K LTC-8640-EMP-C10K LTC-10640-EMP-C10K LTC-12640-EMP-C10K LTC-2650-EMP-C10K DATA FILTERS (9.6 kbps rate) TYPE: (-C10KLV)
Passband Impedance
Stopband Insertion Loss 100 dB min @ 100 kHz to 18 GHz
Passband Loss
600(L-L) 300(L-G)
0.5 dB max 0 - 25 kHz
Model LTC-2640-EMP-C10KLV LTC-4640-EMP-C10KLV LTC-6640-EMP-C10KLV LTC-8640-EMP-C10KLV LTC-10640-EMP-C10KLV LTC-12640-EMP-C10KLV LTC-2650-EMP-C10KLV
No. of Wires 2 4 6 8 10 12 2
Max Current
Max Voltage
0.5 A
Width 3.00" 6.00" 12.00" 12.00" 18.00" 18.00"
75 V
Weight 5 lbs. 10 lbs. 15 lbs. 20 lbs. 25 lbs. 30 lbs. 3 lbs.
ETHERNET HEMP/EMP FIBER OPTIC BASED FILTER Shielding Effectiveness
Insertion Loss Communication Standards
100dB, 10kHz to 10GHz
100dB, 10kHz to 10GHz 1000Base-T/TX (Gigabit Ethernet)
Panel/Cabinet Sizing Chart
LPTC-6x2650-EMP-XXXX
6
Max. # of Wires 12
22
12 ½
6
Approx. Weight Lbs. 20
LPTC-12x2650-EMP-XXXX
12
24
22
22 ½
6
40
LPTC-18x2650-EMP-XXXX
18
36
22
22 ½
8
48
LPTC-24x2650-EMP-XXXX
24
48
22
22 ½
10
60
LPTC-36x2650-EMP-XXXX
36
72
22
22 ½
13
110
LPTC-48x2650-EMP-XXXX
48
96
22
29
13
155
LPTC-78x2650-EMP-XXXX
78
156
22
45
13
185
Part #
XXXX = FILTER TYPE EX: -140Z
Up to # Filters
Height (A) in. Width (B) in.
Depth ( C ) in.
SALES AND SUPPORT OFFICES UNITED STATES – TEXAS
CHINA
Cedar Park, TX
Beijing
+1.512.531.6400 Phone
+86(10)8273.0877 Phone
+1.512.531.6500 Fax
+86(10)8273.0880 Fax
[email protected]
[email protected]
UNITED STATES – ILLINOIS
JAPAN
Wood Dale, IL
Tokyo
+1.630.307.7200 Phone
+81.3.3813.7100 Phone
+1.630.307.7571 Fax
+81.3.3813.8068 Fax
[email protected]
[email protected]
UNITED STATES – WISCONSIN
INDIA
Minocqua, WI
Bangalore
+1.715.356.2022 Phone
+91.80.4341.8600 Phone
+1.715.356.2023 Fax
+91.80.4341.8611 Fax
[email protected]
[email protected]
GERMANY
SINGAPORE
Taufkirchen
Singapore
+49.89.614171.0 Phone
+65.6391.0912 Phone
+49.89.614171.71 Fax
+65.6298.9509 Fax
[email protected]
[email protected]
FINLAND
TAIWAN
Eura
Taipei
+358.2.8383.300 Phone
+886.2.27023389 Phone
+358.2.8651.233 Fax
+886.2.27023055 Fax
[email protected]
[email protected]
UNITED KINGDOM
UNITED ARAB EMIRATES
Stevenage, Hertfordshire
Dubai
+44.1438.730.700 Phone
+971.55.610.4055 Phone
+44.1438.730.751 Fax
[email protected]
[email protected]
FRANCE Boulogne Billancourt +33 (0) 1 74 31 10 21 Phone [email protected]
THE SUREST SOLUTION BY ANY MEASURE™ ets-lindgren.com Information presented is subject to change. Actual product appearance may vary from representational photographs and illustrations shown. Contact the ETS-Lindgren Sales Department for current specifications.
7/15 PDF/RR © 2015 ETS-Lindgren v1.0