Preview only show first 10 pages with watermark. For full document please download

Power Protection Filters Brochure

   EMBED


Share

Transcript

EMP/HEMP/IEMI FILTER SOLUTIONS POWER PROTECTION FILTERS THE SUREST SOLUTION BY ANY MEASURE™ ets-lindgren.com PRODUCT INFORMATION Ideal Protection for Demanding Environments ETS-Lindgren EMP/HEMP power line filters offer excellent multi-stage over-voltage and EMI/RFI protection. These single unit filters are available in either two or four individually filtered lines, with ratings of 227/480 VAC, 30 A to 400 A. These EMP/HEMP series filters are available in the following configurations: • Individual, Stand-alone Single Circuit Filters • “Twin” Dual Circuit Filters for Single Phase Installations • Multiple Line Panel Filters for Facility Installations -- Single Phase -- Three Phase All EMP/HEMP filters meet or exceed the following performance and safety criteria: • MIL-STD-188-125-1 & -2 • MIL-F-15733 • MIL-STD-220C • UL 1283 • IEC 60939 • LVD (2006/95/EC) ETS-Lindgren is ISO 9001:2008 registered through DNV for fabrication of antennas, absorbers, shielding, shielded doors and other system components. We maintain a continuous Quality Assurance program and solicit feedback on quality and product performance. BEIJING  CEDAR PARK  EURA  STEVENAGE  TAUFKIRCHEN Designed to Meet Point-of-Entry Requirements of MIL-STD-188-125-1 & -2 for Short and Intermediate Pulses in Addition to High Insertion Loss Performance for SCIF, TEMPEST and Other Military and Commercial Applications High Frequency Response Design Our filters use a high frequency feed-through capacitor design, which provides better high frequency response. Reliable Transient Suppression Elements Pulse Current Our filters are fitted with high transient suppressors in front of the inductive input circuit. This feature results in very low residual currents during an EMP pulse, protecting the connected equipment. Our filters use suppression elements. These elements protect both the filter and the connected equipment by absorbing and diverting power to ground. Wide Selection of Current Ratings Superior Insertion Loss Performance Custom Designs Available Our filters perform at 100 dB from 14 kHz to 40 GHz at full load. This provides better EMI, RFI, HIRF and IEMI attenuation performance. Extended Filter Life Our filters use oversized inductors for low loss and low temperature rise, resulting in extended filter life. Filter life is further extended by incorporating self-healing capacitors. These filters are available in configurations of 30 A, 60 A, 100 A, 250 A and 400 A at 277/480 VAC. Need something special? ETS-Lindgren can custom design a filter specific to your exact needs. Please contact the ETS-Lindgren Sales Department for further details. PRODUCT SPECIFICATIONS EMP, HEMP and IEMI Power Line Filters Product Specifications RATINGS AND CHARACTERISTICS RATED VOLTAGE TEST VOLTAGE INSULATION RESISTANCE DISCHARGE RESISTORS DISCHARGE TIME MAX. TEMP. RISE ON FULL LOAD FULL LOAD OPERATING TEMP. RANGE LEAKAGE CURRENT AT 250 VAC 50 HZ PEAK SURGE CURRENT 0 - 277/480 RATEDVAC 50/60 Hz VOLTAGE 2250 VDC Each Line TEST toVOLTAGE Case per > 100 MΩ INSULATION (Prior to Fitting RESISTANCE Fitted Internally from DISCHARGE Each Line to Case RESISTORS < 30 sec. DISCHARGE TIME -25 CLOAD to FULL 65o C OPERATING TEMP. RANGE 100 MΩ (Prior to Fitting Fitted Internally from Each Line to Case < 30 sec. 25o C -25o C to 65o C < 10% of Rated Current 70 kA (8/µs) RATINGS AND CHARACTERISTICS UL 1283 and LVD UL 1283 and LVD (Prior to Fitting Transient Suppressors) INSERTION LOSS PERFORMANCE* Minimum Loss in 50 Ω system with/without load FREQUENCY INSERTION LOSS INSERTION LOSS PERFORMANCE* kHz in 50 Ω system with/without 100load dB Minimum14Loss 1 MHz FREQUENCY 100 dB LOSS INSERTION 1014MHz kHz 100 100dB dB 100 MHz 1 MHz 100 100dB dB 1 GHz 10 MHz 100 100dB dB 10 GHz 100 MHz 100 100dB dB 401 GHz GHz 100 100dB dB *Both Symmetric and Asymmetric 10 GHz 100 dB 40 GHz 100 dB Discharge Resistors) Discharge Resistors) PULSE SUPPRESSION PERFORMANCE MIL-STD-188-125-1 acceptance test, short pulse current injection, wave-shape 20/500 ns INPUT PULSE MIL-STD-188-125 RESIDUAL REQUIREMENT AMPLITUDE ANDPERFORMANCE FILTER RESIDUAL LET THROUGH PULSE SUPPRESSION MIL-STD-188-125-1 acceptance test, short pulse current injection, wave-shape 20/500 ns 250 A < 10 A o o SURGE CURRENT PULSE SUPPRESSION PERFORMANCE MIL-STD-188-125-1 acceptance test, intermediate pulse current injection, wave-shape 1.5/300 ns INPUT PULSE MIL-STD-188-125 PULSE SUPPRESSIONREQUIREMENT PERFORMANCE AMPLITUDE TYPICAL FILTER RESPONSE MIL-STD-188-125-1 acceptance test, intermediate pulse current injection, wave-shape 1.5/300 ns 250 A INPUT PULSE 500 A AMPLITUDE MIL-STD-188-125 RESIDUAL REQUIREMENT < 10 A LET THROUGH AND FILTER RESIDUAL INPUT PULSE AMPLITUDE 1000 250 AA << 10 10AA 250 A 1800 500 AA << 10 10AA 2500 1000AA << 10 10AA 1800 A < 10 A 2500 A < 10 A No Filter Damage or Performance Degradation MIL-STD-188-125 No Filter Damage Performance TYPICALDegradation FILTER No Filter Damage or Performance Degradation No Filter Damage Performance Degradation REQUIREMENT *Both Symmetric and Asymmetric 14 kHz Insertion Loss Performance Range RESPONSE CONFIGURATIONS Individual EMP/HEMP Power Line Filters: LRX-EMP Series The LRX-EMP series of filters is available for individual mounting requirements. These filters are supplied in two case styles. The Style 2 (designated as S2) case configuration is designed for direct installation on a shielded room. The Style 3 (designated as S3) case configuration is designed for installation within a shielded filter panel. Style 3 filters can be supplied as individual replacement filters for installation within the LPRX-EMP and LFPRXEMP filter panels. LRX-EMP Filter - Style 2 LRX-EMP Filter - Style 3 A+X 0.75" TYP A B B (5-100 AMP) C (150-400 AMP) 1.50" TYP 1.00" TYP SECURITY COVER SCREW COVER C B (5-100 AMP) C (150-400 AMP) THREADED PENETRATION LRX 5-30 AMP, ADD 6.5" TO A LRX 50-100 AMP, ADD 8.5" TO A LRX 125-225 AMP, ADD 12.5" TO A LRX 250-400 AMP, ADD 11.25" TO A VALUES TO ADD FOR X LRX-EMP FILTER (100 dB, 14 kHz to 40 GHz) Style 2 Style 3 MODEL NUMBER CURRENT RATING HEIGHT “A” LRX-1030-EMP-* 30 A 64.8 cm (25.5 in.) LRX-1060-EMP-* 60 A LRX-1100-EMP-* LRX-1250-EMP-* LRX-1400-EMP-* CASE DIMENSIONS WIDTH “B” DEPTH “C” APPROX. WEIGHT 11.4 cm (4.5 in.) 11.4 cm (4.5 in.) 10.4 kg (23 lbs.) 85.1 cm (33.5 in.) 15.2 cm (6 in.) 17.8 cm (7 in.) 18.1 kg (40 lbs.) 100 A 85.1 cm (33.5 in.) 15.2 cm (6 in.) 17.8 cm (7 in.) 20.4 kg (45 lbs.) 250 A 95.3 cm (37.5 in.) 20.3 cm (8 in.) 25.4 cm (10 in.) 45.4 kg (100 lbs.) 400 A 103.6 cm (40.8 in.) 20.3 cm (8 in.) 30.5 cm (12 in.) 54.4 kg (120 lbs.) * Please specify either S2 (Style 2) or S3 (Style 3) configuration. “Twin” Dual Circuit EMP/HEMP Power Line Filters: LRX-EMP Series “Twin” dual circuit power line filters are designed for wall-mounted installation, and use on AC or DC power lines. These filters can be used for either two-wire AC systems with both lines above ground or three-wire AC systems where one of the conductors is at ground potential and grounded to the filter case. POWER INPUT LOAD 2X RATED CURRENT FILTER CASE GROUND Dual Circuit Power Line Filter A B LRX-EMP TWIN FILTER (100 dB, 14 kHz to 40 GHz) MODEL NUMBER CURRENT RATING LRX-2030-EMP 2 x 30 A 94.0 cm (37 in.) LRX-2060-EMP 2 x 60 A LRX-2100-EMP CL 1.00" TYP SECURITY COVER DEPTH “C” APPROX. WEIGHT 22.9 cm (9 in.) 12.7 cm (5 in.) 31.8 kg (70 lbs.) 111.8 cm (44 in.) 35.6 cm (14 in.) 15.2 cm (6 in.) 36.3 kg (80 lbs.) 2 x 100 A 111.8 cm (44 in.) 35.6 cm (14 in.) 15.2 cm (6 in.) 45.4 kg (100 lbs.) LRX-2250-EMP 2 x 250 A 121.9 cm (48 in.) 35.6 cm (14 in.) 15.2 cm (6 in.) 68.0 kg (150 lbs.) LRX-2400-EMP 2 x 400 A 132.1 cm (52 in.) 61.0 cm (24 in.) 22.9 cm (9 in.) 90.7 kg (200 lbs.) HEIGHT “A” #0.260 MOUNTING HOLE CASE DIMENSIONS WIDTH “B” SCREW COVER C THREADED PENETRATION 1. GROUNDING STUD PROVIDED INSIDE INPUT AND OUTPUT WIRING COMPARTMENTS. 2. ADDITIONAL MOUNTING HOLES PROVIDED IN MOUNTING FLANGE ON 3 AND 4 LINE FILTERS. Multiple Line EMP/HEMP Filters in Panels: LPRX-EMP & LFPRX-EMP Series The LPRX-EMP AND LFPRX-EMP series filters are available in NEMA 1 type panels for wall-mounted and floor-standing installations. These panels incorporate an EM/RFI tight compartment (security well) that meets the highest performance criteria: a full 100 dB shielding effectiveness from 14 kHz to 40 GHz. LPRX -EMP Wall Panels LPRX-EMP FILTER (Wall Mounted, 100 dB, 14 kHz to 40 GHz) B A 2.00 C 1/4" THK MNTG BRKT, w/1/2" DIA. HOLE THRU (4 PL) LFPRX-EMP Floor Panels MODEL NUMBER CURRENT RATING CASE DIMENSIONS WIDTH “B” DEPTH “C” APPROX. WEIGHT LPRX-2x30-EMP 2 x 30 A 91.4 cm (36 in.) 30.5 cm (12 in.) 15.2 cm (6 in.) 36.3 kg (80 lbs.) LPRX-3x30-EMP 3 x 30 A 91.4 cm (36 in.) 61.0 cm (24 in.) 15.2 cm (6 in.) 49.9 kg (110 lbs.) LPRX-4x30-EMP 4 x 30 A 91.4 cm (36 in.) 61.0 cm (24 in.) 15.2 cm (6 in.) 63.5 kg (140 lbs.) LPRX-2x60-EMP 2 x 60 A 121.9 cm (48 in.) 40.6 cm (16 in.) 21.6 cm (8.5 in.) 63.5 kg (140 lbs.) LPRX-3x60-EMP 3 x 60 A 121.9 cm (48 in.) 76.2 cm (30 in.) 21.6 cm (8.5 in.) 90.7 kg (200 lbs.) LPRX-4x60-EMP 4 x 60 A 121.9 cm (48 in.) 76.2 cm (30 in.) 21.6 cm (8.5 in.) 117.9 kg (260 lbs.) LPRX-2x100-EMP 2 x 100 A 121.9 cm (48 in.) 40.6 cm (16 in.) 21.6 cm (8.5 in.) 68.0 kg (150 lbs.) LPRX-3x100-EMP 3 x 100 A 121.9 cm (48 in.) 76.2 cm (30 in.) 21.6 cm (8.5 in.) 97.5 kg (215 lbs.) LPRX-4x100-EMP 4 x 100 A 121.9 cm (48 in.) 76.2 cm (30 in.) 21.6 cm (8.5 in.) 81.6 kg (180 lbs.) CASE DIMENSIONS WIDTH “B” DEPTH “C” APPROX. WEIGHT LPRX -EMP Wall Panels B LFPRX-EMP FILTER (Floor Mounted, 100 dB, 14 kHz to 40 GHz) C MODEL NUMBER A A B CURRENT RATING HEIGHT “A” LFPRX-2x250-EMP 2 x 250 A 188.0 cm (74 in.) 50.8 cm (20 in.) 35.6 cm (14 in.) 163.3 kg (360 lbs.) LFPRX-3x250-EMP 3 x 250 A 188.0 cm (74 in.) 99.1 cm (39 in.) 35.6 cm (14 in.) 231.3 kg (510 lbs.) LFPRX-4x250-EMP 4 x 250 A 188.0 cm (74 in.) 99.1 cm (39 in.) 35.6 cm (14 in.) 299.4 kg (660 lbs.) LFPRX-2x400-EMP 2 x 400 A 188.0 cm (74 in.) 50.8 cm (20 in.) 35.6 cm (14 in.) 172.4 kg (380 lbs.) 188.0 cm (74 in.) 99.1 cm (39 in.) 35.6 cm (14 in.) 244.9 kg (540 lbs.) 188.0 cm (74 in.) 99.1 cm (39 in.) 35.6 cm (14 in.) 317.5 kg (700 lbs.) LFPRX-3x400-EMP 12.0 HEIGHT “A” LFPRX-4x400-EMP 3 x 400 A 2.00 4 x 400 A 1/4" THK MNTG BRKT, w/1/2" DIA. HOLE THRU (4 PL) C ADDENDUM ETS-LINDGREN EMI/RFI//EMP/HEMP/IEMI Filters In addition to our posted catalog and in keeping with ETS-Lindgren’s policy of continued improvement, ETS-Lindgren now offers additional Power and Signal Filters for its EMP/HEMP/IEMI line. EMP/HEMP/IEMI POWER FILTERS ETS-Lindgren now offers power filters for the mitigation and elimination of EMP/HEMP/IEMI pulses according to MILSTD- 188-125. Specifically, these filters pass the E1 requirements for residual currents below 10 Amps and also pass the no-damage requirements of the E2 pulse of MIL-STD-188-125. These filters also offer high performance EMI/RFI protection for military, TEMPEST, and commercial applications per MIL-STD-220. All power filters are rated for voltages up to 277/480 VAC at 50/60 Hz. Current Rating Case Dimension: Height "A" Case Dimension: Width "B" Case Dimension: Depth "C" Approx. Weight LRX-1010-EMP-S2 10A 64.8 cm (25.5 in.) 11.4 cm (4.5 in.) 11.4 cm (4.5 in.) 10.4 Kg (23 lbs.) LRX-1010-EMP-S3 10A 64.8 cm (25.5 in.) 11.4 cm (4.5 in.) 11.4 cm (4.5 in.) 10.4 Kg (23 lbs.) 2x10A 94.0 cm (37 in.) 22.89 cm (9 in.) 12.7 cm (5 in.) 31.8 Kg (70 lbs.) Model Number LRX-2010-EMP LPRX-2x10-EMP 2x10A 91.4 cm (36 in.) 30.5 cm (12 in.) 15.2 cm (6 in.) 36.3 Kg (80 lbs.) LPRX-3x10-EMP 3x10A 91.4 cm (36 in.) 61.0 cm (24 in.) 15.2 cm (6 in.) 52.3 Kg (115 lbs.) LPRX-4x10-EMP 4x10A 91.4 cm (36 in.) 61.0 cm (24 in.) 15.2 cm (6 in.) 63.5 Kg (140 lbs.) Current Rating Case Dimension: Height "A" Case Dimension: Width "B" Case Dimension: Depth "C" Approx. Weight 600A 134 cm (52.7 in.) 25.4 cm (10 in.) 40.6 cm (16 in.) 113.6 Kg (250 lbs.) Model Number LRX-1600-EMP-S3 LPRX-2x600-EMP TBA TBA TBA TBA LPRX-3x600-EMP 3x600A 2x600A 208.3 cm (82 in.) 119.4 cm (47 in.) 45.7 cm (18 in.) 568.2 Kg (1250 lbs.) LPRX-4x600-EMP 4x600A 208.3 cm (82 in.) 119.4 cm (47 in.) 45.7 cm (18 in.) 681.8 Kg (1500 lbs.) LFPRX when floor mounting needed. Model Number Current Rating Case Dimension: Height "A" Case Dimension: Width "B" Case Dimension: Depth "C" Approx. Weight 159.1 Kg (350 lbs.) LRX-1800-EMP-S3 800A 116.8 cm (46 in.) 55.9 cm (22 in.) 25.4 cm (10 in.) LPRX-2x800-EMP 2x800A TBA TBA TBA TBA LPRX-3x800-EMP 3x800A 238.8 cm (94 in.) 236.2 cm (93 in.) 35.6 cm (14 in.) 840.9 Kg (1850 lbs.) LPRX-4x800-EMP 4x800A 238.8 cm (94 in.) 236.2 cm (93 in.) 35.6 cm (14 in.) 1000 Kg (2200 lbs.) Current Rating Case Dimension: Height "A" Case Dimension: Width "B" Case Dimension: Depth "C" Approx. Weight LRX-11250-EMP-S3 1250A 182.9 cm (72 in.) 55.9 cm (22 in.) 33 cm (13 in.) 454.5 Kg (1000 lbs.) LPRX-2x1250-EMP 2x1250A TBA TBA TBA TBA LPRX-3x1250-EMP 3x1250A 274.3 cm (108 in.) 177.8 cm (70 in.) 40.6 cm (16 in.) 1500 Kg (3300 lbs.) LPRX-4x1250-EMP 4x1250A 304.8 cm (120 in.) 256.5 cm (101 in.) 50.8 cm (20 in.) 2000 Kg (4400 lbs.) Model Number Current Rating Case Dimension: Height "A" Case Dimension: Width "B" Case Dimension: Depth "C" Approx. Weight LPRX-1x3600-EMP* 3600A 274.3 cm (108 in.) 177.8 cm (70 in.) 40.6 cm (16 in.) 1500 kg. (3300 lbs.) Model Number * Four units required for a 3 phase plus Neutral system. EMP/HEMP/IEMI SIGNAL FILTERS ETS-Lindgren has also expanded the offering of signal filters for the mitigation and elimination of EMP/HEMP/IEMI pulses according to MIL-STD-188-125. Specifically, these filters pass the E1 requirements for residual currents and also pass the nodamage requirements of the E2 pulse of MIL-STD-188-125. The signal filters offer the appropriate passband to allow desired signals to pass though without degradation, but also offer high performance EMI/RFI protection for military, TEMPEST, and commercial applications per MIL-STD-220. PHONE (POTS) FILTERS TYPE: (-600ZLV) Passband Loss Stopband Insertion Loss 600(L-L) 1.0 dB max 100 dB min @ 300(L-G) 0 - 5 kHz Passband Impedance Model 14 kHz to 18 GHz Max Current Max Voltage 0.5 A 90 V No. of Wires Width LTC-2640-EMP-600ZLV 2 3.00" Weight 5 lbs. LTC-4640-EMP-600ZLV 4 6.00" 10 lbs. 15 lbs. LTC-6640-EMP-600ZLV 6 12.00" LTC-8640-EMP-600ZLV 8 12.00" 20 lbs. LTC-10640-EMP-600ZLV 10 18.00" 25 lbs. LTC-12640-EMP-600ZLV LTC-2650-EMP-600ZLV 12 18.00" 30 lbs. 3 lbs. 2 MULTIPLE LINE CASE DIMENSIONS PHONE (POTS) FILTERS TYPE: (-600ZHV) Passband Loss Stopband Insertion Loss 600(L-L) 1.0 dB max 100 dB min @ 300(L-G) 0 - 5 kHz Passband Impedance Model 14 kHz to 18 GHz Max Current Max Voltage 0.5 A 250 V No. of Wires Width LTC-2640-EMP-600ZLV 2 3.00" Weight 5 lbs. LTC-4640-EMP-600ZLV 4 6.00" 10 lbs. 15 lbs. LTC-6640-EMP-600ZLV 6 12.00" LTC-8640-EMP-600ZLV 8 12.00" 20 lbs. LTC-10640-EMP-600ZLV 10 18.00" 25 lbs. LTC-12640-EMP-600ZLV LTC-2650-EMP-600ZLV 12 18.00" 30 lbs. 3 lbs. 2 LTC-2650-EMP-XXXX CASE DIMENSIONS CONTROL FILTERS TO BE USED IN CABINET/PANEL FILTERS TYPE: (-2053LV) Passband Impedance 40(L-L) 20(L-G) Passband Loss 1.0 dB max 0 - 1 kHz Model No. of Wires Stopband Insertion Loss 100 dB min @ 14 kHz to 18 GHz Width Max Current Max Voltage 3A 75 V TYPE: (-140Z) 2 3.00" 5 lbs. LTC-4640-EMP-2053LV 4 6.00" 10 lbs. LTC-6640-EMP-2053LV 6 12.00" 15 lbs. LTC-8640-EMP-2053LV 8 12.00" 20 lbs. LTC-10640-EMP-2053LV 10 18.00" 25 lbs. LTC-12640-EMP-2053LV 12 18.00" 30 lbs. LTC-2650-EMP-2053LV 2 3 lbs. TYPE: (-2053HV) Passband Loss 40(L-L) 1.0 dB max 20(L-G) 0 - 1 kHz Model Loss 100 dB min @ 14 kHz to 18 GHz Max Current Max Voltage 3A 250 V Width LTC-2640-EMP-2053HV 2 3.00" 5 lbs. LTC-4640-EMP-2053HV 4 6.00" 10 lbs. LTC-6640-EMP-2053HV 6 12.00" 15 lbs. LTC-8640-EMP-2053HV 8 12.00" 20 lbs. Weight LTC-10640-EMP-2053HV 10 18.00" 25 lbs. LTC-12640-EMP-2053HV 12 18.00" 30 lbs. 2 Stopband Insertion Loss 100 dB min @ 70(L-G) 0 - 4 kHz 100 kHz to 18 GHz Passband Loss 3 lbs. Max Current Max Voltage 0.5 A 75 V No. of Wires Width LTC-2640-EMP-140Z 2 3.00" 5 lbs. LTC-4640-EMP-140Z 4 6.00" 10 lbs. LTC-6640-EMP-140Z 6 12.00" 15 lbs. LTC-8640-EMP-140Z 8 12.00" 20 lbs. LTC-10640-EMP-140Z 10 18.00" 25 lbs. LTC-12640-EMP-140Z 12 18.00" 30 lbs. LTC-2650-EMP-140Z No. of Wires LTC-2650-EMP-2053LV 1.0 dB max Model CONTROL FILTERS (High Voltage) Passband Impedance 140(L-L) Passband Impedance Weight LTC-2640-EMP-2053LV Stopband Insertion AUDIO FILTERS 2 Weight 3 lbs. PUBLIC ADDRESS (PA) SYSTEM FILTERS TYPE: (-5000Z) Passband Impedance 5000(L-L) 2500(L-G) Model Passband Loss Stopband Insertion Max Current Max Voltage 1.0 dB max 0 - 4 kHz 100 dB min @ 100 kHz to 18 GHz 0.025 A 70 V Weight Loss No. of Wires Width LTC-2640-EMP-5000Z 2 3.00" 5 lbs. LTC-4640-EMP-5000Z 4 6.00" 10 lbs. LTC-6640-EMP-5000Z 6 12.00" 15 lbs. LTC-8640-EMP-5000Z 8 12.00" 20 lbs. LTC-10640-EMP-5000Z 10 18.00" 25 lbs. LTC-12640-EMP-5000Z 12 18.00" 30 lbs. LTC-2650-EMP-5000Z 2 3 lbs. ADDENDUM DATA FILTERS (9.6 kbps rate) TYPE:FILTERS (-C10K)(9.6 kbps rate) DATA TYPE: (-C10K) Passband Impedance High Voltage Stopband Insertion Loss Passband Loss 600(L-L) 300(L-G) 0.5 dB max 0 - 25 kHz Model Max Current Max Voltage 0.5 A 220 V 100 dB min @ 100 kHz to 18 GHz No. of Wires Width Weight 2 4 6 8 10 12 2 3.00" 6.00" 12.00" 12.00" 18.00" 18.00" 5 lbs. 10 lbs. 15 lbs. 20 lbs. 25 lbs. 30 lbs. 3 lbs. LTC-2640-EMP-C10K LTC-4640-EMP-C10K LTC-6640-EMP-C10K LTC-8640-EMP-C10K LTC-10640-EMP-C10K LTC-12640-EMP-C10K LTC-2650-EMP-C10K DATA FILTERS (9.6 kbps rate) TYPE: (-C10KLV) Passband Impedance Stopband Insertion Loss 100 dB min @ 100 kHz to 18 GHz Passband Loss 600(L-L) 300(L-G) 0.5 dB max 0 - 25 kHz Model LTC-2640-EMP-C10KLV LTC-4640-EMP-C10KLV LTC-6640-EMP-C10KLV LTC-8640-EMP-C10KLV LTC-10640-EMP-C10KLV LTC-12640-EMP-C10KLV LTC-2650-EMP-C10KLV No. of Wires 2 4 6 8 10 12 2 Max Current Max Voltage 0.5 A Width 3.00" 6.00" 12.00" 12.00" 18.00" 18.00" 75 V Weight 5 lbs. 10 lbs. 15 lbs. 20 lbs. 25 lbs. 30 lbs. 3 lbs. ETHERNET HEMP/EMP FIBER OPTIC BASED FILTER Shielding Effectiveness Insertion Loss Communication Standards 100dB, 10kHz to 10GHz 100dB, 10kHz to 10GHz 1000Base-T/TX (Gigabit Ethernet) Panel/Cabinet Sizing Chart LPTC-6x2650-EMP-XXXX 6 Max. # of Wires 12 22 12 ½ 6 Approx. Weight Lbs. 20 LPTC-12x2650-EMP-XXXX 12 24 22 22 ½ 6 40 LPTC-18x2650-EMP-XXXX 18 36 22 22 ½ 8 48 LPTC-24x2650-EMP-XXXX 24 48 22 22 ½ 10 60 LPTC-36x2650-EMP-XXXX 36 72 22 22 ½ 13 110 LPTC-48x2650-EMP-XXXX 48 96 22 29 13 155 LPTC-78x2650-EMP-XXXX 78 156 22 45 13 185 Part # XXXX = FILTER TYPE EX: -140Z Up to # Filters Height (A) in. Width (B) in. Depth ( C ) in. SALES AND SUPPORT OFFICES UNITED STATES – TEXAS CHINA Cedar Park, TX Beijing +1.512.531.6400 Phone +86(10)8273.0877 Phone +1.512.531.6500 Fax +86(10)8273.0880 Fax [email protected] [email protected] UNITED STATES – ILLINOIS JAPAN Wood Dale, IL Tokyo +1.630.307.7200 Phone +81.3.3813.7100 Phone +1.630.307.7571 Fax +81.3.3813.8068 Fax [email protected] [email protected] UNITED STATES – WISCONSIN INDIA Minocqua, WI Bangalore +1.715.356.2022 Phone +91.80.4341.8600 Phone +1.715.356.2023 Fax +91.80.4341.8611 Fax [email protected] [email protected] GERMANY SINGAPORE Taufkirchen Singapore +49.89.614171.0 Phone +65.6391.0912 Phone +49.89.614171.71 Fax +65.6298.9509 Fax [email protected] [email protected] FINLAND TAIWAN Eura Taipei +358.2.8383.300 Phone +886.2.27023389 Phone +358.2.8651.233 Fax +886.2.27023055 Fax [email protected] [email protected] UNITED KINGDOM UNITED ARAB EMIRATES Stevenage, Hertfordshire Dubai +44.1438.730.700 Phone +971.55.610.4055 Phone +44.1438.730.751 Fax [email protected] [email protected] FRANCE Boulogne Billancourt +33 (0) 1 74 31 10 21 Phone [email protected] THE SUREST SOLUTION BY ANY MEASURE™ ets-lindgren.com Information presented is subject to change. Actual product appearance may vary from representational photographs and illustrations shown. Contact the ETS-Lindgren Sales Department for current specifications. 7/15 PDF/RR © 2015 ETS-Lindgren v1.0