Transcript
F Generator controllers
- Lovato
F-1 – 3
Battery chargers
- Lovato
F-4
Power factor controllers
- Lovato
F-5
Capacitor switching contactors
- Lovato
F-6
Power capacitors
- Alpes Technologies - Electronicon
F-7 – 10 F-11
Power factor systems
- EM
F-8 – 10
Active / passive harmonic filters
- Schaffner
F-12
UPS (uninterruptible power supplies)
- Socomec
F-13
- Finder Occupancy sensors - Hager
F-14 F-15
Power quality & efficiency
Product page
Engine / Generator controllers
RGK 600
with “AMF” function 144 x 144 mm panel mounting
Main functions for RGK600 - RGK601 • • • • • •
“Autocall” function for automatic sending of emails and/or SMS at predefined events/alarms Generator controls: Phase sequence, max. and min. voltage and frequency, voltage asymmetry Programmable maintenance Panel mount (H) 144 x (W) 144mm 5 Digital inputs plus 3 x shared resistive or digital (fuel-pressure-temperature) 6 Digital outputs (SSR)
General characteristics
w
ne
RGK600
– Vac inputs: Mains and generator L1-L2-L3-N – Voltage control for one, two and three phase systems with or without neutral – Rated measurement voltage: 480Vac / range: 50-576Vac – Frequency measurement range: 45-65Hz – Current measurement range (3 PH): 0.050-6A or 0.050-1.2A – USB/optical and Wi-Fi port on front facial for programming, diagnostics and data download – Engine running detection: “D+”, generator voltage and frequency – 3 analog resistance inputs for oil pressure, engine temperature and fuel level control – Alarm, event and parameter text in 5 languages – Alarm text customisable (8 alarms) – Event log (non-volatile memory for event storage) – Modbus-RTU and Modbus-ASCII communication protocols type
battery description voltage
RGK 600
with AMF function
price
with and without “AMF” function
With “W” or magnetic “pickup” for engine speed reading (no CANbus) RGK600 RGK600SA
12/24Vdc 12/24Vdc
gen-set controller - front optical port with AMF function gen-set controller - front optical port without AMF function
yes no
6727.00 6315.00
yes no
7093.00 6681.00
With CANbus-J11939 (no “W” or magnetic “pickup”) RGK601 RGK601SA
12/24Vdc 12/24Vdc
gen-set controller - front optical port with AMF function gen-set controller - front optical port without AMF function
RGK 700
with and without “AMF” function
Main functions for RGK700 • • • • • • •
Menus for quick selection of rated parameter settings “Autocall” function for automatic sending of emails and/or SMS at predefined events/alarms Generator controls: Phase sequence, max. and min. voltage and frequency, voltage asymmetry Programmable maintenance Panel mount (H)180 x (W) 240mm 7 Digital inputs - plus 3 x shared resistive or digital (fuel-pressure-temperature) 7 Digital outputs 3 (relay) + 4 (SSR)
General characteristics
RGK700
– Vac inputs: Mains and generator L1-L2-L3-N – Voltage control for one, two and three phase systems with or without neutral – Rated measurement voltage: 600Vac – Rated measurement voltage range: 30-720Vac – Frequency measurement range: 45-65Hz – Current measurement range (3 PH): 0.050-6A or 0.050-1.2A – USB/optical and Wi-Fi port on front facial for programming, diagnostics and data download – Engine running detection: “D+”, generator voltage and frequency – 2 engine speed inputs: “W” or Magnetic “Pick-up” – CANbus-J1939 port – 3 analog resistance inputs for oil pressure, engine temperature and fuel level control – 1 built-in alarm remoting port – Non-volatile memory for event storage – Alarm, event and parameter text in 5 languages (total 60 alarms) – Alarm text customisable (4 alarms) – Event log – Modbus-RTU and Modbus-ASCII communication protocols – PLC logic for inputs, outputs and internal status – Communication port: RS232 – Degree of protection: IP65 on front, suitable for outdoor installations type
F-1
battery voltage
description price
RGK700
12/24Vdc
gen-set controller - front optical port with AMF function
9839.00
RGK700SA
12/24Vdc
gen-set controller - front optical port without AMF function
9381.00
Above prices do not include VAT. E&OE
Power quality & efficiency
Engine / Generator controllers
RGK800 Main functions for RGK800 • • • • • • • • • RGK800
Graphic backlight LCD 128 x 80 pixels Menus for quick selection of rated parameter settings “Autocall” function for automatic sending of emails and/or SMS at predefined events/alarms Generator controls: Phase sequence, max. and min. voltage and frequency, voltage asymmetry Programmable maintenance Panel mount (H) 180 x (W) 240mm 9 Digital inputs - plus 3 x shared resistive or digital (fuel-pressure-temperature) 10 Digital outputs 3 (relay) + 6 (SSR) + 1 (SO) Expandable with up to 3 x plug-in expansion modules (see page F-5 for modules)
Same as RGK700 but with following additional features: – Communication port: RS485 – Neutral measurement range: 0.05-6A or 0.05-1.2A – 400Hz frequency support – 1 programmable analog input – Modbus-TCP communication protocol – Current leakage control towards earth/ground – Clock-calendar (RTC) type
battery voltage
RGK800
12/24Vdc
RGK800SA
12/24Vdc
description price gen-set controller - front optical port with AMF function 12127.00 gen-set controller - front optical port without AMF function
11669.00
RGK900 Main functions for RGK900
w
ne
• • • • • • • • •
Graphic backlight LCD 128 x 112 pixels Menus for quick selection of rated parameter settings “Autocall” function for automatic sending of emails and/or SMS at predefined events/alarms Generator controls: Phase sequence, max. and min. voltage and frequency, voltage asymmetry Programmable maintenance Panel mount (H) 180 x (W) 240mm 13 Digital inputs - plus 3 x shared resistive or digital (fuel-pressure-temperature) 10 Digital outputs 3 (8A relay) + 6 (2A SSR protected) + 1 (50mA SO) Expandable with up to 4 x plug-in expansion modules (see page F-5 for modules)
Same as RGK800 but with following additional features:
RGK900
– Alarm, event and parameter text in 5 languages (total 67 alarms) – Alarm text customisable (16 alarms) – Fourth CT for neutral measurement or earth/ground leakage detection – Boolean logic for inputs, outputs and internal status – 2 analog outputs for engine speed control (governor) /voltage regulator (AVR) – Built-in buzzer – Multi-level passwords – Sleep function (power saving mode) – Synchronising and load sharing – Mains / Generator controls: Phase sequence, phase loss, max and min voltage and frequency, voltage asymmetry – Programmable maintenance at various intervals – Mains-generator synchronising (ATS closed transition) – Mains in base-load with generator in peak shaving – Paralleling supervision of generators (island mode) – Generating set start scheduling type
Above prices do not include VAT. E&OE
battery voltage
description price
RGK900SA
12/24Vdc
paralleling control among generating sets RS485
28600.00
RGK900
12/24Vdc
mains-generator paralleling control RS485
29058.00
RGK900MC
12/24Vdc
control of mains, automatic transfer switching (ATS) and paralleling on multiple generators controlled by RGK900SA
22194.00
F-2
Automatic transfer switch controllers
ATL automatic transfer switch controllers The ATL automatic transfer switch controller is designed to accommodate the automatic (or manual) transfer of a utility from a principle power source to a stand-by source, includes all necessary features to control and supervise generating sets and relative transfer equipment. • • • • • • • • • •
w
ne
Supervision and remote control two, three-phase supply lines Emergency demand supervision for standby generating sets Control of contactors, motorised circuit breakers or motorised changeover switches Event logging TRMS measurements of voltage values 6 programmable digital inputs 7 programmable relay outputs Graphic LCD display Front optic interface port for programming, data download, diagnostics Modbus-RTU and Modbus-ASCII communication protocols
type
aux housing description price supply size (mm)
ATL600
automatic transfer controller
• AC power supply ATL600
ATL610
110-240Vac
automatic transfer switch controller
144 x 144
7780.00
144 x 144
9976.00
automatic transfer controller
• Dual power supply (110-240Vac line and 12-24Vdc battery supply) • 2 rear expansion slots accept plug-in expansion modules • Virtual calendar clock (RTC) ATL600
ATL610
Accessories
dual supply
automatic transfer switch controller
for above ATL switches
ATLSW C2
setup and communication software PC-ATL connecting cable 1.8m/6ft long
ATL600/610 ATL600/610
9730.00 648.00
EXP8001
IP65 gasket seal for ATL display frame
ATL600/610
87.00
Engine protection controllers • Economic control unit for engine protection • Manually start and stop engines via front mounted key selector (external key required for RGK30) • Automatically monitors and shuts down engine in case of faults RGK30
type
battery supply
description price
RGK 30 manual start controller (economic version) • • • • •
Universal supply: LED indication of: 4 digital inputs: 2 relay outputs: Engine running inputs:
RGK 30 RGK20
12/24Vdc
48 x 96 mm panel mounting
12/24Vdc run, pre-heat, overspeed, oil pressure, temperature, change fault, auxiliary shutdown pressure, temperature, emergency, external start (all configurable) fuel valve, start, pre-heat (one programmable) alternator, “D+”, “W/AC” economical genset manual start/protection controller
RGK 20 manual start controller (economic version)
1511.00
72 x 72 mm panel mounting
As RGK30 above with additional tamperproof LCD display indicates engine running hours, battery voltage, engine speed, frequency. RGK 20
12/24Vdc
gen-set controller with built-in power key switch, with TTL port
RGK 40 stand alone gen-set controllers
2151.00
72 x 72 mm panel mounting
• 4 digit LED display: generator voltage, current, power, frequency, battery voltage, engine operating hours • 5 digital inputs: pressure, temperature, fuel level, emergency and auxiliary • 1 x (+) digital input: for remote start • 4 static outputs for: fuel, starting, glow-plugs, alarm • 1 changeover relay output (programmable) • TTL/RS232 port: for easy, fast set-up of controller RGK40
F-3
RGK 40
12/24Vdc
gen-set controller with built-in power key switch, with TTL port
4409.00
Above prices do not include VAT. E&OE
Switchmode battery chargers • Switchmode technology • Charging cycle in accordance with DIN 41773 standards • Automatic reset at end of alarm conditions type
output output voltage current
max. power consumption VA W
dimensions (mm) (H)
(W)
(D)
price
BCE modular automatic switching battery chargers • • • • •
BCF...
Modular DIN rail mounting (aligns with standard MCB’s) or chassis mount Wide auxiliary supply range 100…240Vac (±10%) 50/60Hz Protection: - mains input fuse (non replaceable) - battery output fuse - electronic lock in case of short circuit on battery terminals, reverse battery polarity and battery overload LED indication of: - correct output voltage - reverse battery polarity Alarm output relay (3A 250Vac) AC1 duty
BCF025012 BCF045012
12V 12V
2.5A 4.5A
80 150
49 70
auto battery charger auto battery charger
96 96
90 90
56 56
1144.00 1419.00
BCF012524 BCF025024
24V 24V
1.25A 2.5A
80 150
39 77
auto battery charger auto battery charger
96 96
90 90
56 56
1144.00 1419.00
Mount switching battery chargers
w
ne
BCG ...
• High efficiency • Wide auxiliary supply range 110…240Vac (±10%) 50/60Hz • DIN rail or chassis mounting (can be mounted vertically with adaptor) • Boost signal controlled by external contact • Hiccup function for battery recharging when its voltage is lower than 50% rated value • Maximum charging current limiting trimmer 20-100% (adjustable from front) • Protection - mains input fuse - electronic lock in case of short circuit on battery terminals, reverse battery polarity and battery overload • LED indication of: - power ON - charging operation I>30% Ic - overload or short circuit condition - reverse battery polarity • Alarm output relay (5A 30Vdc) duty BCG0612 BCG1212
12V 12V
6A 12A
230 284
97 290
auto battery charger auto battery charger
150 150
162 162
63 63
2243.00 4348.00
BCG0524 BCG1024
24V 24V
5A 10A
364 630
158 311
auto battery charger auto battery charger
150 150
213 213
63 63
2243.00 4348.00
Accessories for above BCG battery chargers BCG X00
vertical mount adaptor (for space saving) for BCG0612 and BCG0524
76.00
BCE series linear battery chargers • Linear technology • Auxiliary supply voltage: 220-240Vac (±10%) 50/60Hz • Charging current: 30-100% i.e (adjustable) • Protection: - mains input fuse (except BCE2V5 and BCE03) - battery output fuse - electronic lock in case of short circuit on battery terminals, reverse battery polarity output overload <0.5 Ue and disconnected battery • LED indication of: - power ON - charge I>0.2 Ic - alarm for protection tripping • Alarm output: static NPN transistor BCE2V5 and BCE03 - others relay (5A 250Vac)
BCE...
Above prices do not include VAT. E&OE
BCE 0312 BCE 0612 BCE 1212
12V 12V 12V
3 6 12
17 222 400
– – –
auto battery charger auto battery charger auto battery charger
93 130 230
134 192 192
100 140 140
3001.00 4840.00 7133.00
BCE 2V524 BCE 0524 BCE 1024
24V 24V 24V
2.5 5 10
166 317 610
– – –
auto battery charger auto battery charger auto battery charger
93 130 230
134 192 192
100 140 140
3185.00 5210.00 7884.00
F-4
Power quality & efficiency
Automatic battery chargers
Power factor controllers
New DCRL / DCRG power factor controllers incorporate latest technological advanced monitoring to provide accurate measurement and control of network parameters in power factor correction applications, providing total protection of capacitors and systems. Front optic USB port permits easy, safe connection for controller programming, diagnostic and data downloads via PC, smartphone and tablet connection.
w
• • • • • • • •
ne
Expandable through clip-in expansion modules (I/Os, Comm ports etc.) High accuracy (TRMS) measurements with configurable alarms Front optic interface port for programming, data download and diagnostics Suitable for medium voltage systems (with VT’s) Wide voltage measurement range: 50-720Vac L-L, 50-415VAC L-N Configurable 1A or 5A current input Capacitor overload protection Panel over-temperature protection by internal sensor no steps
type
DCRL...
expand
DCRL controllers 3 and 5 step
housing size (mm)
description
price
single phase CT connection 96 x 96mm²
DCRL series power factor controllers with advanced functionality in a dedicated ultra compact housing, combine modern front design with ease of mounting and expendability.
w
ne
• • • •
3 or 5 steps (expandable by another 2 steps with expansion module) Backlit icon LCD display (alarm codes with scrolling text) 128 x 80 pixels Reactive power measurement per step installed Voltage and current THD with single harmonic analysis up to 15° order
DCRL 3 DCRL 5
3 step 5 step
5 step 7 step
DCRG controllers 8 step
panel mount power factor controller panel mount power factor controller
96 x 96 96 x 96
3204.00 3707.00
single and three-phase CT connection 144 x 144mm²
DCRG series power factor controllers are designed to satisfy technical characteristics of modern electrical installation requirements in all industries and working conditions, to detect critical operating conditions and offer total protection of power factor systems.
DCRG 8
• • • • • • • • •
8 steps (expandable by up to another 8 steps with plug-in expansion modules) Three current inputs permit per phase analysis of all electrical parameters of the installation Quick CT programming function / Automatic identification of direction of CT current flow Backlit graphic LCD display (permits reading in bar-graph and wave form format) Connection to 1/3 ph lines, 3 ph + N and co-generation systems with 4 quadrant operation Capacitor over-current protection on all three phases Recording of number of connections per step Configurable for fast dynamic (thyristor) switching with appropriate expansion modules Calendar-clock (RTC) with backup reserve for event logging: Alarms, setup changes, etc.
DCRG 8
8 step
16 step
EXP expansion modules
panel mount power factor controller
144 x 144
5949.00
(plug into rear of controller to add more functionality)
Inputs/outputs EXP10 06 EXP10 00 EXP10 01 EXP10 02 EXP10 03 EXP10 04 EXP10 05 EXP10 16
CX 02
*
2 relay outputs to increase number of capacitor steps 4 opto-isolated digital inputs 4 opto isolated static outputs to increase number of static steps 2 opto-isolated digital inputs and 2 opto-isolated static outputs 2 relay outputs rated 5A 250Vac 2 opto-isolated analog inputs PT100 or 0/4-20mA or 0-10V or 0…±5mA 2 opto-isolated analog inputs 0/4-20mA or 0-10V or 0…±5mA 2 NTC 01 temperature measurements and 2 three phase current inputs
551.00 1141.00 1141.00 1369.00 1369.00 4106.00 4106.00 3695.00
opto-isolated USB interface opto-isolated RS232 interface opto-isolated RS485 interface opto-isolated Ethernet interface with web server function opto-isolated Profibus-DP interface GPRS/GSM modem without antenna
2053.00 2053.00 2053.00 4409.00 8328.00 5305.00
setup and automatic test software (supplied with C2 connecting cable) PC - DCRL/DCRG connecting cable + EXP10 11 module PC - Analog modem connecting cable PC - DCRL/DCRG connecting cable with USB dongle PC - DCRL/DCRG Wi-Fi dongle GSM Quad-band antenna for EXP10 15 modem (800/900/1800/1900MHz)
8476.00 648.00 849.00 1981.00 4950.00 927.00
Communication
* * *
EXP10 10 EXP10 11 EXP10 12 EXP10 13 EXP10 14 EXP10 15
EXP...
* Only available for DCRG Accessories
CX 01
F-5
DCRJ SW C2 C9 CX 01 CX 02 CX 03
Above prices do not include VAT. E&OE
Lovatoʼs special capacitor switching contactors are equipped with early-make limiting resistors that limit in-rush currents initially before making contact. The resistors disconnected from the circuit when the contactor closing operation is complete. type
max operating power kvar kvar 400V 440V
rated auxiliary current contact
description
price
Capacitor switching contactors BFK1210A BFK1810A BFK2600A BFK3800A BF65K00 BF80K00
BFK1810A
capacitor switching contactor capacitor switching contactor capacitor switching contactor capacitor switching contactor capacitor switching contactor capacitor switching contactor
971.00 1177.00 1441.00 1868.00 4020.00 3878.00
G460
for contactor BF0910A, BF1210A, BF1810A, BF2600A, BF3200A, BF3800A
401.00
G464
for contactor BF5000, BF6500, BF8000
634.00
12.5 15 20 30 45 60
14 17 22 33 50 65
18A 23A 30A 43A 70A 90A
1NO 1NO ‒ ‒ ‒ ‒
Power quality & efficiency
Capacitor switching contactors
Kit to assemble BFK contactors from standard contactors
L1 1
L2 3
L3 5
BFK80K00
A1
13
14
A2
2 T1
4 T2
6 T3
Auxiliary contact 13-14 is found on BFK09 A - BFK12 A - BFK18 A types . only
G460
CHOICE OF CONTACTORS TYPE BFK/BF...K Contactor Built-in IEC rated IEC fuse Maximum IEC power auxiliar y operational current gG Thyristor switching modules at ≤50°C (AC6b) contacts 220V • Suitable for dynamic (fast)230 power factorVcorrection NO 380V • Capacitor switching at current flow zero-crossing ≤440V 240V 400V
415V 440V
500V 690V
Type
[kvar]
[kvar ]
n°
[A]
• Prevents high in-rush currents at capacitor switching
[A]
BFK12 A
1
18
BFK18 A
1
23
BFK26 A
– –
30
DCTM3 40040 030
BFK38 A BF65K
– – – –
43 70
DCTM3 40063 050 100
BF80K
– –
90
type
25 40
DCTM3 400 100
125
[kvar]
kvar 400V
kvar 7 440V
rated current
30
11 36
50
17 60 26
100
9
20
34
[kvar]
operational 12.5 description 14 voltage
price 16
15
17
43A
20 400-480V
22 module thyristor switching
72A
30 400-525V 45
33 module 16016.00 36 thyristor switching 50 56
144A
400-525V
60
20 22 11212.00
thyristor switching module 20821.00
65
70
DCTM... Consult Customer Service (see contact details on inside front cover) for the use of contactors to switch within delta connectio n.
CHOICE OF CONT TYPE BFK/BF..K Above prices ACTORS do not include VAT. E&OE ACCORDING TO cULus LISTING Contactor Built-in UL/CSA UL/CSA
Maximum UL/CSA operatio nal
F-6
Power capacitors and racks
Alpivar capacitors are totally dry units, impregnated (under vacuum) with thermoset polyurethane resin, providing excellent mechanical and electrical protection. The patented vacuum potting technique ensures excellent resistance over time and provides much longer service life than conventional capacitors. • • • • • • • • •
VH03040
Rated voltage: Max. voltage overload: Max. current overload: Dielectric losses: Operating temperature: Insulation class: Discharge resistors: Internal protection: Standards:
type
440V 50Hz three-phase 1.18 Un permanent 1.50 In continuous <0.3W per kvar -25°C to 55°C (24 hr average: 45°C - annual average: 35°C) 6kV for 1 minute at 50Hz - 1.2/50μS impulse withstand: 25kV incorporated (<50V within 180 seconds) - self-healing dielectric (metallised polypropylene film) - electrical fuse (per internal element) - overpressure disconnecting device (per element) IEC/EN 60831 and 2, NFC 54108-9l CSA 22-2 no. 190, UL 810
kvar at: dimensions (mm) description 440V 400V (H) (W) (D)
price
440V three-phase heavy-duty capacitors (520V permanent)
VH10040
VH01240 VH01540 VH02040 VH02540 VH03040 VH04040 VH05040 VH06040 VH07540 VH08040 VH10040
15 20 25 30 40 50 60 75 90 100 120
12.5 15 20 25 30 40 50 60 75 80 100
3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor
275 275 275 275 275 275 275 275 275 275 275
90 90 90 90 90 180 180 180 270 360 360
225 225 225 225 225 225 225 225 225 225 225
2056.00 2205.00 2385.00 2545.00 4230.00 4570.00 4910.00 6790.00 7290.00 9025.00 9705.00
RC series single-step rack system (440V capacitors) sheet metal mounting frame (for panel mounting) RC series power factor racks are designed for direct panel mounting into systems accommodating 19” racks. They utilise special “six terminal” capacitors with contactors connected in the delta loop of the capacitors.
RCS05004
RC series rack design incorporates the following: • Alpivar heavy duty “dry” cell capacitors (6 terminal with internal discharge resistors) • Special capacitor switching contactors 400Vac (230V on request) • Three-phase busbar mounted fuse holder with suitably rated HRC fuse links • Incorporated busbar, supports and connecting links RCS01204 15 12.5 single capacitor bank rack 248 RCS01504 20 15 single capacitor bank rack 248 RCS02004 25 20 single capacitor bank rack 248 RCS02504 30 25 single capacitor bank rack 248 RCS03004 40 30 single capacitor bank rack 248 RCS04004 50 40 single capacitor bank rack 248 RCS05004 60 50 single capacitor bank rack 248 RCS06004 75 60 single capacitor bank rack 248 RCS08004 100 80 single capacitor bank rack 248 RCS10004 120 100 single capacitor bank rack 248
550 550 550 550 550 550 550 550 550 550
400 5765.00 400 5960.00 400 6380.00 400 6570.00 400 9030.00 400 9460.00 400 9840.00 400 13890.00 400 16470.00 400 17120.00
RC series double-step racks (440V capacitors) separate fuse protection for each bank
RCD10024
RCD02524 RCD04024 RCD05024 RCD06024 RCD08024 RCD10024 RCD03734 RCD06034 RCD07534
2 x 15 2 x 25 2 x 30 2 x 40 2 x 50 2 x 60 15 + 30 25 + 50 30 + 60
2 x 12.5 2 x 20 2 x 25 2 x 30 2 x 40 2 x 50 12.5+25 20 + 40 25 + 50
double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack
248 248 248 248 248 248 248 248 248
9790.00 10960.00 11340.00 16160.00 16965.00 17775.00 10560.00 13960.00 14555.00
550 550 550 550 550 550 550 550 550
400 400 400 400 400 400 400 400 400
700 700 700 700
460 11070.00 460 17560.00 460 20280.00 460 28410.00
HRR series racks with reinforced reactors (THDU ≤6% and/or THDI ≤40%) HR series racks incorporate the following: • Heavy duty Alpivar3 capacitors mounted on sheet metal frame • Suitably rated switching contactor 400Vac (230V on request) • Anti-harmonic de-tuned reactor (for networks with THDU ≤6% and/or THDI ≤40%) • Three-phase busbar mounted fuse holder with suitably rated HRC fuse links • Incorporated busbar, supports and connecting links
HRR05004
HRR01204 HRR02504 HRR05004 HRR07504
15 30 60 90
12.5 25 50 75
single capacitor bank rack single capacitor bank rack single capacitor bank rack single capacitor bank rack
325 325 325 325
Replace last digit “4” with a “2” for 230V coil voltage
F-7
Above prices do not include VAT. E&OE
Power factor systems (automatic) 400/440V For applications with changing capacitor requirements an automatic reactive controller monitors the network and only switches required capacitor banks as and when they are required. FM series floor standing systems (137 - 900 kvar - 400V) Complete ready-to-install, suitably ventilated floor standing system comprising: • Mains isolator, door interlocking (with early make/late break auxiliary contact) • Automatic reactive control relay (incorporating digital display of all important network parameters) • Suitably rated “special” capacitor switching contactors kvar at: 440V 400V
type
steps (kvar) at 400V
expands to (kvar)
dimensions (mm) price (H) (W) (D)
FM series floor standing complete power factor systems (440V capacitors) • • •
FMS...
Reverse-flow roof mounted exhaust fan (for improved cooling and ventilation) Bottom cable entry (top entry on request) RC series racks - heavy duty capacitors - “special” capacitor switching contactors - fusegear and busbars per capacitor bank
FMS13704 FMS15004 FMS17504 FMS21304 FMS22504 FMS23804 FMS25004 FMS27504 FMS30004 FMS32504 FMS35004 FMS37504 FMS40004 FMS42504 FMS45004
165 180 210 240 270 285 300 330 360 390 420 450 480 510 540
137 150 175 200 225 238 250 275 300 325 350 375 400 425 450
12.5-25-50-50 25-25-50-50 25-50-50-50 25-25-50-50-50 25-50-50-100 12.5-25-50-50-100 25-25-50-50-100 25-50-50-50-100 25-25-50-50-50-100 25-50-50-100-100 25-25-50-50-100-100 25-50-100-100-100 50-50-100-100-100 25-50-50-100-100-100 25-25-50-50-100-100-100
450 450 450 450 450 450 450 450 450 450 450 450 450 450 –
2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200
600 600 600 600 600 600 600 600 600 600 600 600 600 600 600
500 44760.00 500 45670.00 500 49150.00 500 56040.00 500 59520.00 500 63600.00 500 64510.00 500 67990.00 500 74880.00 500 78360.00 500 81850.00 500 86830.00 500 90315.00 500 97200.00 500 102185.00
600 660 720 780 840 900 960 1020 1080
500 550 600 650 700 750 800 850 900
50-50-100-100-100-100 50-100-100-100-100-100 50-50-5x100 50-6x100 50-50-6x100 50-7x100 50-50-7x100 50-8x100 50-50-8x100
900 900 900 900 900 900 900 900 –
2200 2200 2200 2200 2200 2200 2200 2200 2200
1200 1200 1200 1200 1200 1200 1200 1200 1200
500 500 500 500 500 500 500 500 500
129200.00 139570.00 148040.00 158410.00 167430.00 177800.00 186270.00 196240.00 205660.00
For installations subject to harmonics on sites utilising harmonic generating devices such as variable speed drives, inverters, UPS system etc. Complete ready-to-connect floor standing system comprising: • Suitably ventilated floor standing enclosure (roof mounted exhaust fan) • Mains isolator, door interlocking (with early make/late break auxiliary contact) • Automatic reactive control relay (incorporating digital display of all important network parameters) • Series HR racks incorporating following: - Heavy duty Alpivar capacitors - Fusegear and busbars per capacitor bank - Anti-harmonic de-tuned reactor (for networks with THDU ≤6% and/or THDI ≤40%) FHR12504 150 125 25-50-50 300 2200 860 600 FHR15004 180 150 25-50-75 300 2200 860 600 FHR20004 240 200 25-50-50-75 300 2200 860 600 FHR22504 270 225 25-50-75-75 300 2200 860 600 FHR25004 300 250 50-50-75-75 300 2200 860 600 FHR27504 330 275 50-75-75-75 300 2200 860 600 FHR30004 360 300 75-75-75-75 – 2200 860 600
83020.00 90810.00 104800.00 110740.00 118535.00 124780.00 132570.00
FMS50024 FMS55024 FMS60024 FMS65024 FMS70024 FMS75024 FMS80024 FMS85024 FMS90024
* * * * * * * * *
FH series floor standing systems incorporating anti-harmonic de-tuned reactors
FHR...
*
Above prices do not include VAT. E&OE
* * * * * * * * *
420 350 50-75-75-75-75 600 2200 1720 FHR35004 490 425 50-75-75-75-75-75 600 2200 1720 FHR42504 600 500 50-75-75-75-75-75-75 600 2200 1720 FHR50004 680 575 50-75-75-75-75-75-75-75 600 2200 1720 FHR57504 720 600 75-75-75-75-75-75-75-75 – 2200 1720 FHR60004 780 650 50-8X75 900 2200 2580 FHR65004 870 725 50-9X75 900 2200 2580 FHR72504 960 800 50-10X75 900 2200 2580 FHR80004 1080 900 12X75 – 2200 2580 FHR90004 Made up by combining two/three panels with one controller operating all capacitor banks
600 600 600 600 600 600 600 600 600
162155.00 184950.00 212900.00 240300.00 267190.00 297720.00 319710.00 347120.00 374840.00
F-8
Power quality & efficiency
Power factor systems (automatic)
Power factor systems / Remote monitoring / Anti-harmonic reactors
Wall mount power factor systems (automatic) 400/440V For applications with changing capacitor requirements. An automatic reactive controller monitors the network and only switches required capacitor banks as and when they are required, avoiding potential over or under compensation in a network. WM series wall mount systems (37 - 150 kvar - 400V) Complete ready-to-install system comprising following: • • • •
Suitably ventilated wall mounting enclosure Mains isolator, door interlocking (with early make/late break auxiliary contact) Automatic reactive control relay (incorporating digital display of all important network parameters) Suitably rated “special” capacitor switching contactors
type WMS...
kvar at: 440V 400V
steps (kvar) at 400V
expands to (kvar)
dimensions (mm) price (H) (W) (D)
WM series wall-mount complete power factor systems (440V capacitors) - Reverse-flow fan ventilated enclosure, bottom cable entry (top entry on request) - Heavy duty three phase capacitors (with internal discharge resistors) - HRC fuse protection (per capacitor bank) WMS03704 WMS05004 WMS06204 WMS07504 WMS08704 WMS10004 WMS11204 WMS12504 WMS13704 WMS15004
45 60 75 90 105 120 135 150 165 180
38 50 63 75 88 100 113 125 138 150
12.5-25 12.5-12.5-25 12.5-25-25 12.5-12.5-25-25 12.5-25-25-25 12.5-12.5-25-25-25 12.5-25-25-25-25 12.5-12.5-25-25-50 12.5-25-25-25-50 25-25-25-25-50
87.5 87.5 87.5 87.5 – 150 150 150 150 –
700 700 700 700 700 700 700 700 700 700
600 600 600 600 600 900 900 900 900 900
300 300 300 300 300 300 300 300 300 300
21260.00 25450.00 26640.00 30330.00 32025.00 38155.00 39850.00 43535.00 45230.00 46920.00
De-tuned anti-harmonic reactors 400V, 50Hz De-tuned reactors protect capacitors against harmonics, avoiding parallel resonance and amplification of harmonics flowing in the network. Reactors in series with capacitors cause a shift in the resonance frequency of the circuit composed by feeding transformer - reactors - capacitors so that the resulting self-resonance frequency is well below the line harmonics. RERH6...
• • • •
Blocking factor: Tuning frequency: Internal thermal protection: Reference standards:
type
p% 7% - tuning order 3.78 189 Hz class H insulation level IEC/EN 60389
kvar at: dimensions (mm) description 440V 400V (H) (W) (D)
price
Reinforced class reactors (for use with standard 3 terminal capacitors) RERH-7/400/13.3 RERH-7/400/26.6 RERH-7/400/53.3
15 30 60
12.5 25 50
anti-harmonic reactor anti-harmonic reactor anti-harmonic reactor
275 220 255
240 240 300
150 160 205
4075.00 4990.00 7320.00
275 275 260 350
240 240 300 360
170 180 185 200
4393.00 5355.00 7917.00 10525.00
Reinforced class reactors (for use with 6 terminal capacitors) RERH6-7/400/13.3 RERH6-7/400/26.6 RERH6-7/400/53.3 RERH6-7/400/80
15 30 60 90
12.5 25 50 75
anti-harmonic reactor anti-harmonic reactor anti-harmonic reactor anti-harmonic reactor
Remote monitoring of power factor systems (only for floor standing systems) To ensure continuous operation and saving with a fully operational system Lovato provide accessories for simple installation into the power factor controller for detailed remote monitoring. Can only be used with DCRG 8 controller used on FM and FH series floor standing systems. • GSM modem simply plugs directly into back of reactive control relay CX 03
EXP10 15
plug-in GPRS/GSM modem for monitoring (without antenna)
CX 03
GSM Quad-band antenna for above plug-in modem
5305.00 927.00
EXP10 15
F-9
Above prices do not include VAT. E&OE
525V capacitors and rack systems Rated voltage: 525V 50Hz three-phase Max. voltage overload: 1.18 Un permanent Max. current overload: 1.50 In continuous Dielectric losses: <0.3W per kvar Operating temperature: -25°C to 55°C (24 hr average: 45°C - annual average: 35°C) Insulation class: 6kV for 1 minute at 50Hz - 1.2/50μS impulse withstand: 25kV Internal protection: - self-healing dielectric (metallised polypropylene film) - electrical fuse (per internal element) - overpressure disconnecting device (per element) Standards: IEC/EN 60831 and 2, NFC 54108-9l CSA 22-2 no. 190, UL 810 kvar at: dimensions (mm) description 525V 400V (H) (W) (D)
type
price
VH04052
525V three-phase heavy-duty capacitors (620V permanent) VH01052 VH02052 VH03052 VH04052 VH05052 VH06052 VH07052 VH08052
10 20 30 40 50 60 70 80
6 12 17 23 29 35 41 46
525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor
275 275 275 275 275 275 275 275
90 90 180 180 270 270 360 360
225 225 225 225 225 225 225 225
2200.00 2655.00 4680.00 5140.00 7175.00 7630.00 9710.00 10160.00
RC series rack system (525V capacitors)
RCS04005
RC series power factor racks are designed for direct panel mounting into systems accommodating 19” racks. They utilise special “six terminal” capacitors with contactors connected in the delta loop of the capacitors. RC series rack design incorporates the following: • Alpivar heavy duty “dry” cell capacitors (6 terminal with internal discharge resistors) • Special capacitor switching contactors • Three-phase busbar mounted fuse holder with suitably rated HRC fuse links RCS02005 20 12.5 525V single capacitor bank rack 248 550 400 6820.00 RCS04005 40 25 525V single capacitor bank rack 248 550 400 10230.00 RCS06005 60 35 525V single capacitor bank rack 248 550 400 14970.00 RCS08005 80 46 525V single capacitor bank rack 248 550 400 17780.00 RC series double-step racks (525V capacitors) separate fuse protection for each bank RCD04025 20 + 20 12 + 12 525V double capacitor bank rack 248 550 RCD06035 20 + 40 12 + 24 525V double capacitor bank rack 248 550 RCD08025 40 + 40 24 + 24 525V double capacitor bank rack 248 550
400 400 400
11875.00 15285.00 18690.00
Power factor systems (automatic) 525V For applications with changing capacitor requirements. An automatic reactive controller monitors the network and only switches required capacitor banks as and when they are required, avoiding potential over or under compensation in a network.
Complete ready-to-install floor standing system comprising following: • Suitably ventilated floor standing enclosure • Mains isolator, door interlocking (with early make/late break auxiliary contact) • Automatic reactive control relay (incorporating digital display of all important network parameters) FM series floor standing complete power factor systems (525V capacitors) • Reverse-flow roof mounted exhaust fan (for improved cooling and ventilation) • Bottom cable entry (top entry on request) • RC series racks - heavy duty capacitors - “special” capacitor switching contactors - fusegear and busbars per capacitor bank kvar at: 525V 400V
type FMS14005 FMS18005 FMS22005 FMS28005 FMS32005 FMS40005
FMS...
81 104 128 162 186 232
20-40-80 20-40-40-80 20-40-80-80 40-80-80-80 40-40-80-80-80 40-40-80-80-80-80
expands to (kvar) 400 400 400 400 400 –
dimensions (mm) price (H) (W) (D) 2200 2200 2200 2200 2200 2200
600 600 600 600 600 600
460 267 20-40-80-80-80-80-80 800 2200 600 FMS46025 540 313 20-40-6x80 800 2200 600 FMS54025 620 360 20-40-7x80 800 2200 600 FMS62025 680 394 40-8x80 800 2200 600 FMS70025 800 464 40-40-9x80 – 2200 600 FMS80025 Made up by combining two/three panels with one controller operating all capacitor banks
* Above prices do not include VAT. E&OE
* * * * *
140 180 220 280 320 400
steps (kvar) at 525V
500 61265.00 500 71980.00 500 80010.00 500 93460.00 500 102400.00 500 121140.00 500 500 500 500 500
156140.00 175430.00 194180.00 207620.00 235860.00
F-10
Power quality & efficiency
Power factor systems (automatic) 525V
Made in Germany
Power capacitors
Three-phase industrial cylindrical capacitors
w ne
MKPg-275 capacitors are dry gas filled, protecting the windings from environmental influences with extended life expectancy, permitting mounting in any position. Gas used is inert and completely harmless to the environment. • Rated voltage: • Capacitance tolerance: • Dielectric losses: • Duty: • Maximum permissible current: • Protection: • Standards:
275.525-701400
type
440 or 525V 50Hz three-phase -5 ~ +10% <0.2 W/kvar continuous 1.5 ~ 2 In Overpressure disconnection facility IEC/EN 60831, VDE 0560-46/47, CSA C22.2 No. 190M1985, UL, GOST
kvar at: In 440V 400V 3 x (A)
Cn dimensions (mm) description price 3 x (μF) (H) (W)
Three-phase cylindrical capacitors (440V) • M12 base mounted fixing stud (can be mounted horizontally) • Capacitors up to 15kvar supplied with discharge resistors (above 15kvar require discharge module)
275.186-516600
275.525-701400
2.5
2
3.3
14
3-ph 440V cyl capacitor
164
60
739.00
275.526-502800
5.0
4
6.6
28
3-ph 440V cyl capacitor
230
60
797.00
275.545-504000
7.5
6
10
40
3-ph 440V cyl capacitor
164
75
908.00
275.546-505700
10
8
14
57
3-ph 440V cyl capacitor
230
75
990.00
275.546-506800
12.5
10
16
68
3-ph 440V cyl capacitor
230
75
1053.00
275.556-508200
15
12.5
20
82
3-ph 440V cyl capacitor
30
85
1207.00
275.166-511100
20
15
27
111
3-ph 440V cyl capacitor
230
95
1622.00
275.176-513700
25
20
33
137
3-ph 440V cyl capacitor
230
100
1788.00
275.186-516600
30
25
40
116
3-ph 440V cyl capacitor
230
116
2053.00
275.389-522100
40
30
53
221
3-ph 440V cyl capacitor
280
116
2437.00
Three-phase cylindrical capacitors (525V) • M12 base mounted fixing stud (can be mounted horizontally) • Capacitors up to 15kvar supplied with discharge resistors (above 15kvar require discharge module) 275.526-801900
5
3
5.5
19
3-ph 525V cyl capacitor
230
60
853.00
275.546-703803
10
6
11
38
3-ph 525V cyl capacitor
230
75
1007.00
275.556-705800
15
9
17
58
3-ph 525V cyl capacitor
230
85
1195.00
275.176-707700
20
12
22
77
3-ph 525V cyl capacitor
230
100
1708.00
275.189-811503
30
18
33
115
3-ph 525V cyl capacitor
280
116
2323.00
275.398-715401
40
23
44
154
3-ph 525V cyl capacitor
245
136
2925.00
Accessories for cylindrical capacitors Discharge modules for above capacitors 20kvar and above • Simply plugs into capacitor connection terminal 275.100-10120
discharge resistor module for above capacitors 20~40kvar 26.00
275.398-715401
275.100-10120
Plastic protection caps
Ø
275.157-10010
plastic protection caps for capacitor with diameters
85 49.00
275.167-10010
plastic protection caps for capacitor with diameters
95 51.00
275.177-10011
plastic protection caps for capacitor with diameters
100 60.00
275.187-10012
plastic protection caps for capacitor with diameters
116 69.00
275.157-10010
F-11
Above prices do not include VAT. E&OE
ECOsine Active harmonic filters
w ne
FN3420...
Multiple functions: harmonic filtering - reactive power compensation - load balancing Reliability and efficiency are important to business operation. This includes reliable operation of machines, manufacturing systems, and office equipment. Nevertheless, this is frequently not the case and often there is no obvious reason, despite the use of UPS and back-up generators. Unlike passive harmonic filters, these filters can provide harmonic mitigation under any load conditions up to their rated capacity. • • • • • •
Global or selective compensation of harmonic currents up to the 50th order (reduces THID to 1.5% - 3%) Compensation of displacement power factor Load balancing Response time: less than 300 μs Adapts to changing network topologies instantly Up to 5 units can be wired in parallel to increase overall system requirements
type
rated current 400V (A)
phase
ECOsine three wire active harmonic
IP rating
power loss (W)
380 - 480Vac ±10%
dimensions (mm) price (H) (W) (D)
(500-690Vac available on request)
FN3420-50-480-3 50A 3 wire IP20 <1300 615 358 FN3420-120-480-3 120A 3 wire IP20 <2500 972 469 FN3420-200-480-3 200A 3 wire IP54 <5000 2105 808 FN3420-300-480-3 300A 3 wire IP54 <7500 2105 808 4-wire version available on request for triplen harmonic filtering eg. 3rd, 9th, 15th….orders
288 203632.00 412 297440.00 604 1084512.00 604 1255929.00
ECOsine passive harmonic filters ECOsine FN 3416 represent very compact “economy line” with THID performance of ≤10 % in conjunction with the VSD’s built in DC-link choke. Ideal for non-linear three-phase equipment with 6-pulse front end rectifier circuits. Sufficient to comply with EN61000-3-12 or IEEE-519 and other power quality standards. Schaffner ECOsine filters help to unburden electrical infrastructures from excess loading and heat caused by current harmonics, and therefore support better utilization of electric system capacity. Lower harmonics also reduce the risk of system resonances and potential downtime of sensitive electronic equipment. FN 3416 filters upgrade standard motor drives to “low-harmonic drives” quickly and easily. • • • •
THID performance of <10% (5% available on request) Compact design - Quick installation Efficient: >98% nominal line voltage and power Conformity to: UL508, EN61558-2-20, CE (LVD2006 / 95 / EC)
type
rated current 400V (A)
rated load power (kW) 400V 500V
power loss (W)
dimensions (mm) price (H) (W) (D)
FN3420-200-480-3
FN3416-45-33 45A 22 FN3416-60-34 60A 30 FN3416-75-34 75A 37 FN3416-110-35 110A 55 FN3416-150-40 150A 75 Larger sizes up to 200kW available on request
EMC/RFI filters
30 37 45 75 90
306 408 410 546 784
455 520 520 580 700
280 280 280 280 450
230 46712.00 248 53524.00 248 62672.00 248 87195.00 385 102084.00
three-phase filters
Electro Magnetic Interference (EMI) unwanted high frequencies which ride on the AC waveform. Many products such as variable frequency drives generate EMI, which may interrupt, obstruct, degrade or limit the effective performance of electronic equipment.
FN3416-45-33
• • • • • •
Max. continuous operating voltage: 480/277Vac Exceptional attenuation performance from 150kHz to 30Mhz Excellent saturation resistance up 50 meters cable length Most compact and slim filter design in its class Increases the immunity of the equipment being protected Compliance with class A according to EN 55011
type
FN3258-16-44
Above prices do not include VAT. E&OE
FN3258-16-44 FN3258-30-33 FN3258-42-33 FN3258-55-34 FN3258-75-34 FN3258-100-35 FN3258-130-35 FN3258-180-40
rated current 50°C
typical drive size
leakage current 400V
power loss (W)
16A 30A 42A 55A 75A 100A 130A 180A
7.5kW 15kW 22kW 30kW 37kW 55kW 75kW 90kW
33.0 mA 33.0 mA 33.0 mA 33.0 mA 33.0 mA 33.0 mA 33.0 mA 33.0 mA
6.1 11.8 15.7 25.9 32.2 34.5 43.1 58.3
dimensions (mm) (H) (W) (D)
250 270 310 250 270 270 270 380
45 50 50 85 80 90 90 120
price
70 3374.00 85 3949.00 85 4622.00 90 5567.00 135 7093.00 150 8659.00 150 10285.00 170 13352.00
F-12
Power quality & efficiency
Active / Passive harmonic filters
UPS (uninterruptible power supplies)
Single Phase UPS’s
w ne
Socomec single phase Uninterruptible Power Supplies meet all requirements for a high quality, reliable, faultless electrical supply to cover a very wide range of applications for every sector of the market. type
supply load VA Watts
output sockets
NETYS PE 600 to 2000 VA NPE...
• • • • •
back-up dimensions (mm) description price time (H) (W) (D)
VI “line interactive” with AVR step wave
Clean output with Automatic Voltage Regulation Reduces battery ageing Protects data line (Tel/Internet/xDSL/LAN) from surges Delivered with user-friendly software Wide input range: 170 - 280 V Output: 230 V ±10%
NPE-B600 NPE-0650 NPE-0850 NPE-1000-LCD NPE-1500-LCD NPE-2000-LCD
600 650 850 1000 1500 2000
360 360 480 600 900 1200
4 (IEC 320) 4 (IEC 320) 4 (IEC 320) 4 (IEC 320) 6 (IEC 320) 6 (IEC 320)
NETYS PR 1000 to 2000 VA
15 min 15 min 20 min 45 min 55 min 60 min
single phase single phase single phase single phase single phase single phase
145 145 145 165 205 203
100 100 100 145 145 145
290 290 290 345 390 390
1273.00 1471.00 2138.00 3411.00 4658.00 5511.00
145 145 145
345 390 390
5202.00 7302.00 9848.00
VI “line interactive” with AVR sine wave
Solution for professional and IT equipment.
NPR...MT
• • • • •
Sine wave output Clean output with Automatic Voltage Regulation Reduces battery ageing Protects data line (Tel/Internet/xDSL/LAN) from surges Wide input range: 170 - 280 V Output: 230 V ±10%
Mini Tower NPR-1000-MT NPR-1500-MT NPR-2000-MT
1000 1500 2000
700 1050 1400
4 (IEC 320) 6 (IEC 320) 6 (IEC 320)
45 min 55 min 60 min
single phase single phase single phase
165 205 203
Rack/Tower versatile, convertible • Optional battery extension modules to meet all back-up time requirements, even after installation • RS232 advanced connection for management of power supply and local/remote shutdown NPR-1700-RT NPR-2200-RT NPR-3300-RT
1700 2200 3300
1350 1800 2700
8 (IEC 320) 8 (IEC 320) 8 (IEC 320)
Battery extensions NPR-B1700-RT 1700 NPR-B3300-RT 3300
NPR...RT
NETYS RT 1100 to 11000 VA
87 87 87
440 440 440
436 10972.00 608 14777.00 608 19299.00
extension battery for 1700 VA UPS 6919.00 extension battery for 2200 and 3300 VA UPS 13134.00
VFI “online double conversion”
True online double conversion Ready for 1+1 redundant mode Extensive configurability Easy to maintain Ready for LAN connection Versatile product (rack/tower configuration) LOCAL VIEW: UPS monitoring and shutdown point-to-point for Windows, Linux and Mac OS X MODBUS/JBUS RTU (RS232) RT-VISION: professional WEB/SNMP interface for UPS monitoring/shutdown management
Rack/Tower versatile, convertible NRT2-5000K 5000 4500 NRT2-7000K 7000 5400 NRT2-9000K 9000 7200 NRT2-11000K 11000 9000
F-13
single phase single phase single phase
Complete solution for IT infrastructures. Online double conversion technology with sinusoidal waveform, completely filters out all disturbances from / to mains power supply. • • • • • • • • •
NRT2...
6 min 8 min 6 min
Battery extensions NRT-B7000 7000 NRT-B11000 11000
terminals terminals terminals terminals
8 min 6 min 8 min 6 min
single phase single phase single phase single phase
178 178 262 262
440 440 440 440
670 670 623 623
45307.00 54783.00 69993.00 78431.00
extension battery for 5000 and 7000 VA UPS 18595.00 extension battery for 9000 and 11000 VA UPS 23401.00
Above prices do not include VAT. E&OE
18 series - New generation occupancy sensors
w ne
• • • • • • •
Extensive sensing area up to 120m2 Incorporates two sensors “presence” for zones of low activity and “movement” for transit areas Modern design Quick installation through push-in terminals 10A 1 NO “zero cross” switching Supplied with all hardware for recess mounting into wall boxes, suspended ceilings or surface mount Adjustable settings: light on time (since last detection) 12s~35 min sensitivity adjustment lux setting (ambient light intervention threshold) 0~500 lx
type
18.41
switching current
supply voltage
18.41 passage way sensor
switching load (AC1)
description
price
(Ø) 84 x (D) flush: 44 / surface: 85 mm
For use in rectangular areas such as hotel lobbies, corridors, offices and walkways. The use of a special lens combined with electronics, provide a total sensing zone of 30 meters long by 4 meters wide. • Hotel and office corridors, transit areas • Sensing area 30 meters length and 4 meters width 184182300300
10A
100~230Vac
18.51 ceiling mount sensor
2.500 VA
occupancy sensor for corridors
1300.00
(Ø) 84 x (D) flush: 35 / surface: 76 mm
Responds to very small movements, suitable for use in offices, schools, and the workplace. The lens has been developed to achieve two zones of different sensitivity: Zone 1: overall area of 8 x 8 meters sensitive to normal movement Zone 2: central area of 4 x 4 met senses “body presence” by detecting very small movements
18.51
• Offices, schools zones of low activity • Two sensing areas: “presence” and “movement” detection • Sensing area 360° 185182300300
10A
100~230Vac
18.61 wall mount sensor
18.61
2.500 VA
occupancy sensor for offices
1064.00
(Ø) 85 x (D) flush: 28 mm
Latest evolution in movement detector techniques, featuring a wide viewing angle of 180° designed for fitting in new or existing wall boxes as a direct replacement of a wall mounted light switch or push-button. • Specific product for wall mounting to replace standard light switches • Wide angle sensing 180° 186182300300
10A
100~230Vac
2.500 VA
wall mount occupancy sensor
1536.00
Movement detectors (economic version) Compact, economical movement detector for internal installations, these sensors detect movement in common areas and operate lights when required in low ambient areas.
18.21
• • •
Ceiling mounting (compact) Wide angle of survey 360° Adjustable settings:
(8 x 5 met detection at 2.8 met high) “light on” time (since last detection) 10s~12 min lux setting (ambient light intervention threshold) 5~350 lx
18.21 surface mount sensor 182182300000
10A
120~230Vac
18.31 flush mount sensor 183182300000
10A
(Ø) 75 x (D) 50.5 mm 2.500 VA
surface mnt movement detector
690.00
(Ø) 80 x (D) flush: 2 mm 120~230Vac
2.500 VA
surface mnt movement detector
690.00
18.31
Above prices do not include VAT. E&OE
F-14
Power quality & efficiency
Occupancy sensors
Occupancy sensors
Occupancy sensors • • • • •
Detect movement Measure ambient light Automatically switch lights “on” (if ambient is below pre-set level and movement is detected) Automatically switch lights “off” (if no movement is detected after a pre-set time delay period) Complies with: IEC 60669-1 and IEC 60669-2-1 - supply voltage: 230Vac 50Hz - switch current: 8/10/16A 230V (AC1) - lux adjustment: 5 - 1000 lux
EE804 and EE805 motion detectors EE804 and EE805 are 360° indoor movement detectors with a built-in light sensitive switching function. Ideal for use in interior circulation areas such as corridors, entrance halls, bathrooms etc.
EE804
- Operating time delay: - Detection range: type EE804 EE805
5s - 15 min 6 meter radius (at 2.5 meters high) 360°
mounting surface flush
rated price current
description 105.5 mm dia. 75 mm hole
economical motion detector economical motion detector
8A 8A
406.00 432.00
10A
546.00
EE820 basic motion detectors (IP55) Wall mounting with numerous mounting possibilities for indoor or outdoor applications. - Operating time delay: pulse, 5s -15 min - Detection range: 16 met frontal /8 met lateral (at 2.5 meters high)
EE805
EE820
surface
140°
wall mnt. basic occupancy sensor
EE860 enhanced motion detectors (IP55) Offers vertical and horizontal adjustment and area limitation with shutters suitable for indoor or outdoor applications. Wall, inner/outer corner, ceiling mount. Setting and adjustments made via concealed potentionmeters or remote control.
EE820
- Operating time delay: - Detection range: - Sensitivity adjustment:
5s - 15min 16met frontal / 10met lateral (at 2.5 meters high) 20% - 100%
EE860
220°
surface
16A
867.00
EE820 EE820 EE860 EE815/20
60.00 78.00 60.00 496.00
wall mnt. basic occupancy sensor
Accessories EE825 EE827 EE855 EE806
corner mount accessory (inner/outer) ceiling mount accessory corner mount accessory (inner/outer) IR remote control for enhanced series
High-performance combined presence and motion detector High-performance presence detectors combine detection of both presence and motion in an area ideally suited for offices where human presence is detected to maintain lighting level. Motion detection enhances the overall sensing range of the detectors.
EE815 compact flush mount presence detector EE860
Compact super-flush device mounts through a 50mm hole for very neat installation. Settings and adjustments made via concealed potentiometers or remote control. - Operating time delay: - Detection range:
1 min - 1 hour presence 5 meter radius (at 2.5 meters high) motion 7 meter radius (at 2.5 meters high)
EE815
60mm hole
flush
360° enhanced presence detector
16A
1115.00
16A
2133.00
EE810 surface flush mount presence detector EE815
F-15
- Operating time delay: - Detection range: - Lux adjustment
EE810
flush
1 min - 1 hour presence 7 meter radius (at 2.5 meters high) motion 13 meter radius (at 2.5 meters high) 5 - 1200 lux dual sens
360° enhanced presence detector
Above prices do not include VAT. E&OE
Notes
Renewable energy