Preview only show first 10 pages with watermark. For full document please download

Power Quality Efficiency Pdf

   EMBED


Share

Transcript

F Generator controllers - Lovato F-1 – 3 Battery chargers - Lovato F-4 Power factor controllers - Lovato F-5 Capacitor switching contactors - Lovato F-6 Power capacitors - Alpes Technologies - Electronicon F-7 – 10 F-11 Power factor systems - EM F-8 – 10 Active / passive harmonic filters - Schaffner F-12 UPS (uninterruptible power supplies) - Socomec F-13 - Finder Occupancy sensors - Hager F-14 F-15 Power quality & efficiency Product page Engine / Generator controllers RGK 600 with “AMF” function 144 x 144 mm panel mounting Main functions for RGK600 - RGK601 • • • • • • “Autocall” function for automatic sending of emails and/or SMS at predefined events/alarms Generator controls: Phase sequence, max. and min. voltage and frequency, voltage asymmetry Programmable maintenance Panel mount (H) 144 x (W) 144mm 5 Digital inputs plus 3 x shared resistive or digital (fuel-pressure-temperature) 6 Digital outputs (SSR) General characteristics w ne RGK600 – Vac inputs: Mains and generator L1-L2-L3-N – Voltage control for one, two and three phase systems with or without neutral – Rated measurement voltage: 480Vac / range: 50-576Vac – Frequency measurement range: 45-65Hz – Current measurement range (3 PH): 0.050-6A or 0.050-1.2A – USB/optical and Wi-Fi port on front facial for programming, diagnostics and data download – Engine running detection: “D+”, generator voltage and frequency – 3 analog resistance inputs for oil pressure, engine temperature and fuel level control – Alarm, event and parameter text in 5 languages – Alarm text customisable (8 alarms) – Event log (non-volatile memory for event storage) – Modbus-RTU and Modbus-ASCII communication protocols type battery description voltage RGK 600 with AMF function price with and without “AMF” function With “W” or magnetic “pickup” for engine speed reading (no CANbus) RGK600 RGK600SA 12/24Vdc 12/24Vdc gen-set controller - front optical port with AMF function gen-set controller - front optical port without AMF function yes no 6727.00 6315.00 yes no 7093.00 6681.00 With CANbus-J11939 (no “W” or magnetic “pickup”) RGK601 RGK601SA 12/24Vdc 12/24Vdc gen-set controller - front optical port with AMF function gen-set controller - front optical port without AMF function RGK 700 with and without “AMF” function Main functions for RGK700 • • • • • • • Menus for quick selection of rated parameter settings “Autocall” function for automatic sending of emails and/or SMS at predefined events/alarms Generator controls: Phase sequence, max. and min. voltage and frequency, voltage asymmetry Programmable maintenance Panel mount (H)180 x (W) 240mm 7 Digital inputs - plus 3 x shared resistive or digital (fuel-pressure-temperature) 7 Digital outputs 3 (relay) + 4 (SSR) General characteristics RGK700 – Vac inputs: Mains and generator L1-L2-L3-N – Voltage control for one, two and three phase systems with or without neutral – Rated measurement voltage: 600Vac – Rated measurement voltage range: 30-720Vac – Frequency measurement range: 45-65Hz – Current measurement range (3 PH): 0.050-6A or 0.050-1.2A – USB/optical and Wi-Fi port on front facial for programming, diagnostics and data download – Engine running detection: “D+”, generator voltage and frequency – 2 engine speed inputs: “W” or Magnetic “Pick-up” – CANbus-J1939 port – 3 analog resistance inputs for oil pressure, engine temperature and fuel level control – 1 built-in alarm remoting port – Non-volatile memory for event storage – Alarm, event and parameter text in 5 languages (total 60 alarms) – Alarm text customisable (4 alarms) – Event log – Modbus-RTU and Modbus-ASCII communication protocols – PLC logic for inputs, outputs and internal status – Communication port: RS232 – Degree of protection: IP65 on front, suitable for outdoor installations type F-1 battery voltage description price RGK700 12/24Vdc gen-set controller - front optical port with AMF function 9839.00 RGK700SA 12/24Vdc gen-set controller - front optical port without AMF function 9381.00 Above prices do not include VAT. E&OE Power quality & efficiency Engine / Generator controllers RGK800 Main functions for RGK800 • • • • • • • • • RGK800 Graphic backlight LCD 128 x 80 pixels Menus for quick selection of rated parameter settings “Autocall” function for automatic sending of emails and/or SMS at predefined events/alarms Generator controls: Phase sequence, max. and min. voltage and frequency, voltage asymmetry Programmable maintenance Panel mount (H) 180 x (W) 240mm 9 Digital inputs - plus 3 x shared resistive or digital (fuel-pressure-temperature) 10 Digital outputs 3 (relay) + 6 (SSR) + 1 (SO) Expandable with up to 3 x plug-in expansion modules (see page F-5 for modules) Same as RGK700 but with following additional features: – Communication port: RS485 – Neutral measurement range: 0.05-6A or 0.05-1.2A – 400Hz frequency support – 1 programmable analog input – Modbus-TCP communication protocol – Current leakage control towards earth/ground – Clock-calendar (RTC) type battery voltage RGK800 12/24Vdc RGK800SA 12/24Vdc description price gen-set controller - front optical port with AMF function 12127.00 gen-set controller - front optical port without AMF function 11669.00 RGK900 Main functions for RGK900 w ne • • • • • • • • • Graphic backlight LCD 128 x 112 pixels Menus for quick selection of rated parameter settings “Autocall” function for automatic sending of emails and/or SMS at predefined events/alarms Generator controls: Phase sequence, max. and min. voltage and frequency, voltage asymmetry Programmable maintenance Panel mount (H) 180 x (W) 240mm 13 Digital inputs - plus 3 x shared resistive or digital (fuel-pressure-temperature) 10 Digital outputs 3 (8A relay) + 6 (2A SSR protected) + 1 (50mA SO) Expandable with up to 4 x plug-in expansion modules (see page F-5 for modules) Same as RGK800 but with following additional features: RGK900 – Alarm, event and parameter text in 5 languages (total 67 alarms) – Alarm text customisable (16 alarms) – Fourth CT for neutral measurement or earth/ground leakage detection – Boolean logic for inputs, outputs and internal status – 2 analog outputs for engine speed control (governor) /voltage regulator (AVR) – Built-in buzzer – Multi-level passwords – Sleep function (power saving mode) – Synchronising and load sharing – Mains / Generator controls: Phase sequence, phase loss, max and min voltage and frequency, voltage asymmetry – Programmable maintenance at various intervals – Mains-generator synchronising (ATS closed transition) – Mains in base-load with generator in peak shaving – Paralleling supervision of generators (island mode) – Generating set start scheduling type Above prices do not include VAT. E&OE battery voltage description price RGK900SA 12/24Vdc paralleling control among generating sets RS485 28600.00 RGK900 12/24Vdc mains-generator paralleling control RS485 29058.00 RGK900MC 12/24Vdc control of mains, automatic transfer switching (ATS) and paralleling on multiple generators controlled by RGK900SA 22194.00 F-2 Automatic transfer switch controllers ATL automatic transfer switch controllers The ATL automatic transfer switch controller is designed to accommodate the automatic (or manual) transfer of a utility from a principle power source to a stand-by source, includes all necessary features to control and supervise generating sets and relative transfer equipment. • • • • • • • • • • w ne Supervision and remote control two, three-phase supply lines Emergency demand supervision for standby generating sets Control of contactors, motorised circuit breakers or motorised changeover switches Event logging TRMS measurements of voltage values 6 programmable digital inputs 7 programmable relay outputs Graphic LCD display Front optic interface port for programming, data download, diagnostics Modbus-RTU and Modbus-ASCII communication protocols type aux housing description price supply size (mm) ATL600 automatic transfer controller • AC power supply ATL600 ATL610 110-240Vac automatic transfer switch controller 144 x 144 7780.00 144 x 144 9976.00 automatic transfer controller • Dual power supply (110-240Vac line and 12-24Vdc battery supply) • 2 rear expansion slots accept plug-in expansion modules • Virtual calendar clock (RTC) ATL600 ATL610 Accessories dual supply automatic transfer switch controller for above ATL switches ATLSW C2 setup and communication software PC-ATL connecting cable 1.8m/6ft long ATL600/610 ATL600/610 9730.00 648.00 EXP8001 IP65 gasket seal for ATL display frame ATL600/610 87.00 Engine protection controllers • Economic control unit for engine protection • Manually start and stop engines via front mounted key selector (external key required for RGK30) • Automatically monitors and shuts down engine in case of faults RGK30 type battery supply description price RGK 30 manual start controller (economic version) • • • • • Universal supply: LED indication of: 4 digital inputs: 2 relay outputs: Engine running inputs: RGK 30 RGK20 12/24Vdc 48 x 96 mm panel mounting 12/24Vdc run, pre-heat, overspeed, oil pressure, temperature, change fault, auxiliary shutdown pressure, temperature, emergency, external start (all configurable) fuel valve, start, pre-heat (one programmable) alternator, “D+”, “W/AC” economical genset manual start/protection controller RGK 20 manual start controller (economic version) 1511.00 72 x 72 mm panel mounting As RGK30 above with additional tamperproof LCD display indicates engine running hours, battery voltage, engine speed, frequency. RGK 20 12/24Vdc gen-set controller with built-in power key switch, with TTL port RGK 40 stand alone gen-set controllers 2151.00 72 x 72 mm panel mounting • 4 digit LED display: generator voltage, current, power, frequency, battery voltage, engine operating hours • 5 digital inputs: pressure, temperature, fuel level, emergency and auxiliary • 1 x (+) digital input: for remote start • 4 static outputs for: fuel, starting, glow-plugs, alarm • 1 changeover relay output (programmable) • TTL/RS232 port: for easy, fast set-up of controller RGK40 F-3 RGK 40 12/24Vdc gen-set controller with built-in power key switch, with TTL port 4409.00 Above prices do not include VAT. E&OE Switchmode battery chargers • Switchmode technology • Charging cycle in accordance with DIN 41773 standards • Automatic reset at end of alarm conditions type output output voltage current max. power consumption VA W dimensions (mm) (H) (W) (D) price BCE modular automatic switching battery chargers • • • • • BCF... Modular DIN rail mounting (aligns with standard MCB’s) or chassis mount Wide auxiliary supply range 100…240Vac (±10%) 50/60Hz Protection: - mains input fuse (non replaceable) - battery output fuse - electronic lock in case of short circuit on battery terminals, reverse battery polarity and battery overload LED indication of: - correct output voltage - reverse battery polarity Alarm output relay (3A 250Vac) AC1 duty BCF025012 BCF045012 12V 12V 2.5A 4.5A 80 150 49 70 auto battery charger auto battery charger 96 96 90 90 56 56 1144.00 1419.00 BCF012524 BCF025024 24V 24V 1.25A 2.5A 80 150 39 77 auto battery charger auto battery charger 96 96 90 90 56 56 1144.00 1419.00 Mount switching battery chargers w ne BCG ... • High efficiency • Wide auxiliary supply range 110…240Vac (±10%) 50/60Hz • DIN rail or chassis mounting (can be mounted vertically with adaptor) • Boost signal controlled by external contact • Hiccup function for battery recharging when its voltage is lower than 50% rated value • Maximum charging current limiting trimmer 20-100% (adjustable from front) • Protection - mains input fuse - electronic lock in case of short circuit on battery terminals, reverse battery polarity and battery overload • LED indication of: - power ON - charging operation I>30% Ic - overload or short circuit condition - reverse battery polarity • Alarm output relay (5A 30Vdc) duty BCG0612 BCG1212 12V 12V 6A 12A 230 284 97 290 auto battery charger auto battery charger 150 150 162 162 63 63 2243.00 4348.00 BCG0524 BCG1024 24V 24V 5A 10A 364 630 158 311 auto battery charger auto battery charger 150 150 213 213 63 63 2243.00 4348.00 Accessories for above BCG battery chargers BCG X00 vertical mount adaptor (for space saving) for BCG0612 and BCG0524 76.00 BCE series linear battery chargers • Linear technology • Auxiliary supply voltage: 220-240Vac (±10%) 50/60Hz • Charging current: 30-100% i.e (adjustable) • Protection: - mains input fuse (except BCE2V5 and BCE03) - battery output fuse - electronic lock in case of short circuit on battery terminals, reverse battery polarity output overload <0.5 Ue and disconnected battery • LED indication of: - power ON - charge I>0.2 Ic - alarm for protection tripping • Alarm output: static NPN transistor BCE2V5 and BCE03 - others relay (5A 250Vac) BCE... Above prices do not include VAT. E&OE BCE 0312 BCE 0612 BCE 1212 12V 12V 12V 3 6 12 17 222 400 – – – auto battery charger auto battery charger auto battery charger 93 130 230 134 192 192 100 140 140 3001.00 4840.00 7133.00 BCE 2V524 BCE 0524 BCE 1024 24V 24V 24V 2.5 5 10 166 317 610 – – – auto battery charger auto battery charger auto battery charger 93 130 230 134 192 192 100 140 140 3185.00 5210.00 7884.00 F-4 Power quality & efficiency Automatic battery chargers Power factor controllers New DCRL / DCRG power factor controllers incorporate latest technological advanced monitoring to provide accurate measurement and control of network parameters in power factor correction applications, providing total protection of capacitors and systems. Front optic USB port permits easy, safe connection for controller programming, diagnostic and data downloads via PC, smartphone and tablet connection. w • • • • • • • • ne Expandable through clip-in expansion modules (I/Os, Comm ports etc.) High accuracy (TRMS) measurements with configurable alarms Front optic interface port for programming, data download and diagnostics Suitable for medium voltage systems (with VT’s) Wide voltage measurement range: 50-720Vac L-L, 50-415VAC L-N Configurable 1A or 5A current input Capacitor overload protection Panel over-temperature protection by internal sensor no steps type DCRL... expand DCRL controllers 3 and 5 step housing size (mm) description price single phase CT connection 96 x 96mm² DCRL series power factor controllers with advanced functionality in a dedicated ultra compact housing, combine modern front design with ease of mounting and expendability. w ne • • • • 3 or 5 steps (expandable by another 2 steps with expansion module) Backlit icon LCD display (alarm codes with scrolling text) 128 x 80 pixels Reactive power measurement per step installed Voltage and current THD with single harmonic analysis up to 15° order DCRL 3 DCRL 5 3 step 5 step 5 step 7 step DCRG controllers 8 step panel mount power factor controller panel mount power factor controller 96 x 96 96 x 96 3204.00 3707.00 single and three-phase CT connection 144 x 144mm² DCRG series power factor controllers are designed to satisfy technical characteristics of modern electrical installation requirements in all industries and working conditions, to detect critical operating conditions and offer total protection of power factor systems. DCRG 8 • • • • • • • • • 8 steps (expandable by up to another 8 steps with plug-in expansion modules) Three current inputs permit per phase analysis of all electrical parameters of the installation Quick CT programming function / Automatic identification of direction of CT current flow Backlit graphic LCD display (permits reading in bar-graph and wave form format) Connection to 1/3 ph lines, 3 ph + N and co-generation systems with 4 quadrant operation Capacitor over-current protection on all three phases Recording of number of connections per step Configurable for fast dynamic (thyristor) switching with appropriate expansion modules Calendar-clock (RTC) with backup reserve for event logging: Alarms, setup changes, etc. DCRG 8 8 step 16 step EXP expansion modules panel mount power factor controller 144 x 144 5949.00 (plug into rear of controller to add more functionality) Inputs/outputs EXP10 06 EXP10 00 EXP10 01 EXP10 02 EXP10 03 EXP10 04 EXP10 05 EXP10 16 CX 02 * 2 relay outputs to increase number of capacitor steps 4 opto-isolated digital inputs 4 opto isolated static outputs to increase number of static steps 2 opto-isolated digital inputs and 2 opto-isolated static outputs 2 relay outputs rated 5A 250Vac 2 opto-isolated analog inputs PT100 or 0/4-20mA or 0-10V or 0…±5mA 2 opto-isolated analog inputs 0/4-20mA or 0-10V or 0…±5mA 2 NTC 01 temperature measurements and 2 three phase current inputs 551.00 1141.00 1141.00 1369.00 1369.00 4106.00 4106.00 3695.00 opto-isolated USB interface opto-isolated RS232 interface opto-isolated RS485 interface opto-isolated Ethernet interface with web server function opto-isolated Profibus-DP interface GPRS/GSM modem without antenna 2053.00 2053.00 2053.00 4409.00 8328.00 5305.00 setup and automatic test software (supplied with C2 connecting cable) PC - DCRL/DCRG connecting cable + EXP10 11 module PC - Analog modem connecting cable PC - DCRL/DCRG connecting cable with USB dongle PC - DCRL/DCRG Wi-Fi dongle GSM Quad-band antenna for EXP10 15 modem (800/900/1800/1900MHz) 8476.00 648.00 849.00 1981.00 4950.00 927.00 Communication * * * EXP10 10 EXP10 11 EXP10 12 EXP10 13 EXP10 14 EXP10 15 EXP... * Only available for DCRG Accessories CX 01 F-5 DCRJ SW C2 C9 CX 01 CX 02 CX 03 Above prices do not include VAT. E&OE Lovatoʼs special capacitor switching contactors are equipped with early-make limiting resistors that limit in-rush currents initially before making contact. The resistors disconnected from the circuit when the contactor closing operation is complete. type max operating power kvar kvar 400V 440V rated auxiliary current contact description price Capacitor switching contactors BFK1210A BFK1810A BFK2600A BFK3800A BF65K00 BF80K00 BFK1810A capacitor switching contactor capacitor switching contactor capacitor switching contactor capacitor switching contactor capacitor switching contactor capacitor switching contactor 971.00 1177.00 1441.00 1868.00 4020.00 3878.00 G460 for contactor BF0910A, BF1210A, BF1810A, BF2600A, BF3200A, BF3800A 401.00 G464 for contactor BF5000, BF6500, BF8000 634.00 12.5 15 20 30 45 60 14 17 22 33 50 65 18A 23A 30A 43A 70A 90A 1NO 1NO ‒ ‒ ‒ ‒ Power quality & efficiency Capacitor switching contactors Kit to assemble BFK contactors from standard contactors L1 1 L2 3 L3 5 BFK80K00 A1 13 14 A2 2 T1 4 T2 6 T3 Auxiliary contact 13-14 is found on BFK09 A - BFK12 A - BFK18 A types . only G460 CHOICE OF CONTACTORS TYPE BFK/BF...K Contactor Built-in IEC rated IEC fuse Maximum IEC power auxiliar y operational current gG Thyristor switching modules at ≤50°C (AC6b) contacts 220V • Suitable for dynamic (fast)230 power factorVcorrection NO 380V • Capacitor switching at current flow zero-crossing ≤440V 240V 400V 415V 440V 500V 690V Type [kvar] [kvar ] n° [A] • Prevents high in-rush currents at capacitor switching [A] BFK12 A 1 18 BFK18 A 1 23 BFK26 A – – 30 DCTM3 40040 030 BFK38 A BF65K – – – – 43 70 DCTM3 40063 050 100 BF80K – – 90 type 25 40 DCTM3 400 100 125 [kvar] kvar 400V kvar 7 440V rated current 30 11 36 50 17 60 26 100 9 20 34 [kvar] operational 12.5 description 14 voltage price 16 15 17 43A 20 400-480V 22 module thyristor switching 72A 30 400-525V 45 33 module 16016.00 36 thyristor switching 50 56 144A 400-525V 60 20 22 11212.00 thyristor switching module 20821.00 65 70 DCTM... Consult Customer Service (see contact details on inside front cover) for the use of contactors to switch within delta connectio n. CHOICE OF CONT TYPE BFK/BF..K Above prices ACTORS do not include VAT. E&OE ACCORDING TO cULus LISTING Contactor Built-in UL/CSA UL/CSA Maximum UL/CSA operatio nal F-6 Power capacitors and racks Alpivar capacitors are totally dry units, impregnated (under vacuum) with thermoset polyurethane resin, providing excellent mechanical and electrical protection. The patented vacuum potting technique ensures excellent resistance over time and provides much longer service life than conventional capacitors. • • • • • • • • • VH03040 Rated voltage: Max. voltage overload: Max. current overload: Dielectric losses: Operating temperature: Insulation class: Discharge resistors: Internal protection: Standards: type 440V 50Hz three-phase 1.18 Un permanent 1.50 In continuous <0.3W per kvar -25°C to 55°C (24 hr average: 45°C - annual average: 35°C) 6kV for 1 minute at 50Hz - 1.2/50μS impulse withstand: 25kV incorporated (<50V within 180 seconds) - self-healing dielectric (metallised polypropylene film) - electrical fuse (per internal element) - overpressure disconnecting device (per element) IEC/EN 60831 and 2, NFC 54108-9l CSA 22-2 no. 190, UL 810 kvar at: dimensions (mm) description 440V 400V (H) (W) (D) price 440V three-phase heavy-duty capacitors (520V permanent) VH10040 VH01240 VH01540 VH02040 VH02540 VH03040 VH04040 VH05040 VH06040 VH07540 VH08040 VH10040 15 20 25 30 40 50 60 75 90 100 120 12.5 15 20 25 30 40 50 60 75 80 100 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 3-phase industrial capacitor 275 275 275 275 275 275 275 275 275 275 275 90 90 90 90 90 180 180 180 270 360 360 225 225 225 225 225 225 225 225 225 225 225 2056.00 2205.00 2385.00 2545.00 4230.00 4570.00 4910.00 6790.00 7290.00 9025.00 9705.00 RC series single-step rack system (440V capacitors) sheet metal mounting frame (for panel mounting) RC series power factor racks are designed for direct panel mounting into systems accommodating 19” racks. They utilise special “six terminal” capacitors with contactors connected in the delta loop of the capacitors. RCS05004 RC series rack design incorporates the following: • Alpivar heavy duty “dry” cell capacitors (6 terminal with internal discharge resistors) • Special capacitor switching contactors 400Vac (230V on request) • Three-phase busbar mounted fuse holder with suitably rated HRC fuse links • Incorporated busbar, supports and connecting links RCS01204 15 12.5 single capacitor bank rack 248 RCS01504 20 15 single capacitor bank rack 248 RCS02004 25 20 single capacitor bank rack 248 RCS02504 30 25 single capacitor bank rack 248 RCS03004 40 30 single capacitor bank rack 248 RCS04004 50 40 single capacitor bank rack 248 RCS05004 60 50 single capacitor bank rack 248 RCS06004 75 60 single capacitor bank rack 248 RCS08004 100 80 single capacitor bank rack 248 RCS10004 120 100 single capacitor bank rack 248 550 550 550 550 550 550 550 550 550 550 400 5765.00 400 5960.00 400 6380.00 400 6570.00 400 9030.00 400 9460.00 400 9840.00 400 13890.00 400 16470.00 400 17120.00 RC series double-step racks (440V capacitors) separate fuse protection for each bank RCD10024 RCD02524 RCD04024 RCD05024 RCD06024 RCD08024 RCD10024 RCD03734 RCD06034 RCD07534 2 x 15 2 x 25 2 x 30 2 x 40 2 x 50 2 x 60 15 + 30 25 + 50 30 + 60 2 x 12.5 2 x 20 2 x 25 2 x 30 2 x 40 2 x 50 12.5+25 20 + 40 25 + 50 double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack double capacitor bank rack 248 248 248 248 248 248 248 248 248 9790.00 10960.00 11340.00 16160.00 16965.00 17775.00 10560.00 13960.00 14555.00 550 550 550 550 550 550 550 550 550 400 400 400 400 400 400 400 400 400 700 700 700 700 460 11070.00 460 17560.00 460 20280.00 460 28410.00 HRR series racks with reinforced reactors (THDU ≤6% and/or THDI ≤40%) HR series racks incorporate the following: • Heavy duty Alpivar3 capacitors mounted on sheet metal frame • Suitably rated switching contactor 400Vac (230V on request) • Anti-harmonic de-tuned reactor (for networks with THDU ≤6% and/or THDI ≤40%) • Three-phase busbar mounted fuse holder with suitably rated HRC fuse links • Incorporated busbar, supports and connecting links HRR05004 HRR01204 HRR02504 HRR05004 HRR07504 15 30 60 90 12.5 25 50 75 single capacitor bank rack single capacitor bank rack single capacitor bank rack single capacitor bank rack 325 325 325 325 Replace last digit “4” with a “2” for 230V coil voltage F-7 Above prices do not include VAT. E&OE Power factor systems (automatic) 400/440V For applications with changing capacitor requirements an automatic reactive controller monitors the network and only switches required capacitor banks as and when they are required. FM series floor standing systems (137 - 900 kvar - 400V) Complete ready-to-install, suitably ventilated floor standing system comprising: • Mains isolator, door interlocking (with early make/late break auxiliary contact) • Automatic reactive control relay (incorporating digital display of all important network parameters) • Suitably rated “special” capacitor switching contactors kvar at: 440V 400V type steps (kvar) at 400V expands to (kvar) dimensions (mm) price (H) (W) (D) FM series floor standing complete power factor systems (440V capacitors) • • • FMS... Reverse-flow roof mounted exhaust fan (for improved cooling and ventilation) Bottom cable entry (top entry on request) RC series racks - heavy duty capacitors - “special” capacitor switching contactors - fusegear and busbars per capacitor bank FMS13704 FMS15004 FMS17504 FMS21304 FMS22504 FMS23804 FMS25004 FMS27504 FMS30004 FMS32504 FMS35004 FMS37504 FMS40004 FMS42504 FMS45004 165 180 210 240 270 285 300 330 360 390 420 450 480 510 540 137 150 175 200 225 238 250 275 300 325 350 375 400 425 450 12.5-25-50-50 25-25-50-50 25-50-50-50 25-25-50-50-50 25-50-50-100 12.5-25-50-50-100 25-25-50-50-100 25-50-50-50-100 25-25-50-50-50-100 25-50-50-100-100 25-25-50-50-100-100 25-50-100-100-100 50-50-100-100-100 25-50-50-100-100-100 25-25-50-50-100-100-100 450 450 450 450 450 450 450 450 450 450 450 450 450 450 – 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 500 44760.00 500 45670.00 500 49150.00 500 56040.00 500 59520.00 500 63600.00 500 64510.00 500 67990.00 500 74880.00 500 78360.00 500 81850.00 500 86830.00 500 90315.00 500 97200.00 500 102185.00 600 660 720 780 840 900 960 1020 1080 500 550 600 650 700 750 800 850 900 50-50-100-100-100-100 50-100-100-100-100-100 50-50-5x100 50-6x100 50-50-6x100 50-7x100 50-50-7x100 50-8x100 50-50-8x100 900 900 900 900 900 900 900 900 – 2200 2200 2200 2200 2200 2200 2200 2200 2200 1200 1200 1200 1200 1200 1200 1200 1200 1200 500 500 500 500 500 500 500 500 500 129200.00 139570.00 148040.00 158410.00 167430.00 177800.00 186270.00 196240.00 205660.00 For installations subject to harmonics on sites utilising harmonic generating devices such as variable speed drives, inverters, UPS system etc. Complete ready-to-connect floor standing system comprising: • Suitably ventilated floor standing enclosure (roof mounted exhaust fan) • Mains isolator, door interlocking (with early make/late break auxiliary contact) • Automatic reactive control relay (incorporating digital display of all important network parameters) • Series HR racks incorporating following: - Heavy duty Alpivar capacitors - Fusegear and busbars per capacitor bank - Anti-harmonic de-tuned reactor (for networks with THDU ≤6% and/or THDI ≤40%) FHR12504 150 125 25-50-50 300 2200 860 600 FHR15004 180 150 25-50-75 300 2200 860 600 FHR20004 240 200 25-50-50-75 300 2200 860 600 FHR22504 270 225 25-50-75-75 300 2200 860 600 FHR25004 300 250 50-50-75-75 300 2200 860 600 FHR27504 330 275 50-75-75-75 300 2200 860 600 FHR30004 360 300 75-75-75-75 – 2200 860 600 83020.00 90810.00 104800.00 110740.00 118535.00 124780.00 132570.00 FMS50024 FMS55024 FMS60024 FMS65024 FMS70024 FMS75024 FMS80024 FMS85024 FMS90024 * * * * * * * * * FH series floor standing systems incorporating anti-harmonic de-tuned reactors FHR... * Above prices do not include VAT. E&OE * * * * * * * * * 420 350 50-75-75-75-75 600 2200 1720 FHR35004 490 425 50-75-75-75-75-75 600 2200 1720 FHR42504 600 500 50-75-75-75-75-75-75 600 2200 1720 FHR50004 680 575 50-75-75-75-75-75-75-75 600 2200 1720 FHR57504 720 600 75-75-75-75-75-75-75-75 – 2200 1720 FHR60004 780 650 50-8X75 900 2200 2580 FHR65004 870 725 50-9X75 900 2200 2580 FHR72504 960 800 50-10X75 900 2200 2580 FHR80004 1080 900 12X75 – 2200 2580 FHR90004 Made up by combining two/three panels with one controller operating all capacitor banks 600 600 600 600 600 600 600 600 600 162155.00 184950.00 212900.00 240300.00 267190.00 297720.00 319710.00 347120.00 374840.00 F-8 Power quality & efficiency Power factor systems (automatic) Power factor systems / Remote monitoring / Anti-harmonic reactors Wall mount power factor systems (automatic) 400/440V For applications with changing capacitor requirements. An automatic reactive controller monitors the network and only switches required capacitor banks as and when they are required, avoiding potential over or under compensation in a network. WM series wall mount systems (37 - 150 kvar - 400V) Complete ready-to-install system comprising following: • • • • Suitably ventilated wall mounting enclosure Mains isolator, door interlocking (with early make/late break auxiliary contact) Automatic reactive control relay (incorporating digital display of all important network parameters) Suitably rated “special” capacitor switching contactors type WMS... kvar at: 440V 400V steps (kvar) at 400V expands to (kvar) dimensions (mm) price (H) (W) (D) WM series wall-mount complete power factor systems (440V capacitors) - Reverse-flow fan ventilated enclosure, bottom cable entry (top entry on request) - Heavy duty three phase capacitors (with internal discharge resistors) - HRC fuse protection (per capacitor bank) WMS03704 WMS05004 WMS06204 WMS07504 WMS08704 WMS10004 WMS11204 WMS12504 WMS13704 WMS15004 45 60 75 90 105 120 135 150 165 180 38 50 63 75 88 100 113 125 138 150 12.5-25 12.5-12.5-25 12.5-25-25 12.5-12.5-25-25 12.5-25-25-25 12.5-12.5-25-25-25 12.5-25-25-25-25 12.5-12.5-25-25-50 12.5-25-25-25-50 25-25-25-25-50 87.5 87.5 87.5 87.5 – 150 150 150 150 – 700 700 700 700 700 700 700 700 700 700 600 600 600 600 600 900 900 900 900 900 300 300 300 300 300 300 300 300 300 300 21260.00 25450.00 26640.00 30330.00 32025.00 38155.00 39850.00 43535.00 45230.00 46920.00 De-tuned anti-harmonic reactors 400V, 50Hz De-tuned reactors protect capacitors against harmonics, avoiding parallel resonance and amplification of harmonics flowing in the network. Reactors in series with capacitors cause a shift in the resonance frequency of the circuit composed by feeding transformer - reactors - capacitors so that the resulting self-resonance frequency is well below the line harmonics. RERH6... • • • • Blocking factor: Tuning frequency: Internal thermal protection: Reference standards: type p% 7% - tuning order 3.78 189 Hz class H insulation level IEC/EN 60389 kvar at: dimensions (mm) description 440V 400V (H) (W) (D) price Reinforced class reactors (for use with standard 3 terminal capacitors) RERH-7/400/13.3 RERH-7/400/26.6 RERH-7/400/53.3 15 30 60 12.5 25 50 anti-harmonic reactor anti-harmonic reactor anti-harmonic reactor 275 220 255 240 240 300 150 160 205 4075.00 4990.00 7320.00 275 275 260 350 240 240 300 360 170 180 185 200 4393.00 5355.00 7917.00 10525.00 Reinforced class reactors (for use with 6 terminal capacitors) RERH6-7/400/13.3 RERH6-7/400/26.6 RERH6-7/400/53.3 RERH6-7/400/80 15 30 60 90 12.5 25 50 75 anti-harmonic reactor anti-harmonic reactor anti-harmonic reactor anti-harmonic reactor Remote monitoring of power factor systems (only for floor standing systems) To ensure continuous operation and saving with a fully operational system Lovato provide accessories for simple installation into the power factor controller for detailed remote monitoring. Can only be used with DCRG 8 controller used on FM and FH series floor standing systems. • GSM modem simply plugs directly into back of reactive control relay CX 03 EXP10 15 plug-in GPRS/GSM modem for monitoring (without antenna) CX 03 GSM Quad-band antenna for above plug-in modem 5305.00 927.00 EXP10 15 F-9 Above prices do not include VAT. E&OE 525V capacitors and rack systems Rated voltage: 525V 50Hz three-phase Max. voltage overload: 1.18 Un permanent Max. current overload: 1.50 In continuous Dielectric losses: <0.3W per kvar Operating temperature: -25°C to 55°C (24 hr average: 45°C - annual average: 35°C) Insulation class: 6kV for 1 minute at 50Hz - 1.2/50μS impulse withstand: 25kV Internal protection: - self-healing dielectric (metallised polypropylene film) - electrical fuse (per internal element) - overpressure disconnecting device (per element) Standards: IEC/EN 60831 and 2, NFC 54108-9l CSA 22-2 no. 190, UL 810 kvar at: dimensions (mm) description 525V 400V (H) (W) (D) type price VH04052 525V three-phase heavy-duty capacitors (620V permanent) VH01052 VH02052 VH03052 VH04052 VH05052 VH06052 VH07052 VH08052 10 20 30 40 50 60 70 80 6 12 17 23 29 35 41 46 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 525V 3-phase industrial capacitor 275 275 275 275 275 275 275 275 90 90 180 180 270 270 360 360 225 225 225 225 225 225 225 225 2200.00 2655.00 4680.00 5140.00 7175.00 7630.00 9710.00 10160.00 RC series rack system (525V capacitors) RCS04005 RC series power factor racks are designed for direct panel mounting into systems accommodating 19” racks. They utilise special “six terminal” capacitors with contactors connected in the delta loop of the capacitors. RC series rack design incorporates the following: • Alpivar heavy duty “dry” cell capacitors (6 terminal with internal discharge resistors) • Special capacitor switching contactors • Three-phase busbar mounted fuse holder with suitably rated HRC fuse links RCS02005 20 12.5 525V single capacitor bank rack 248 550 400 6820.00 RCS04005 40 25 525V single capacitor bank rack 248 550 400 10230.00 RCS06005 60 35 525V single capacitor bank rack 248 550 400 14970.00 RCS08005 80 46 525V single capacitor bank rack 248 550 400 17780.00 RC series double-step racks (525V capacitors) separate fuse protection for each bank RCD04025 20 + 20 12 + 12 525V double capacitor bank rack 248 550 RCD06035 20 + 40 12 + 24 525V double capacitor bank rack 248 550 RCD08025 40 + 40 24 + 24 525V double capacitor bank rack 248 550 400 400 400 11875.00 15285.00 18690.00 Power factor systems (automatic) 525V For applications with changing capacitor requirements. An automatic reactive controller monitors the network and only switches required capacitor banks as and when they are required, avoiding potential over or under compensation in a network. Complete ready-to-install floor standing system comprising following: • Suitably ventilated floor standing enclosure • Mains isolator, door interlocking (with early make/late break auxiliary contact) • Automatic reactive control relay (incorporating digital display of all important network parameters) FM series floor standing complete power factor systems (525V capacitors) • Reverse-flow roof mounted exhaust fan (for improved cooling and ventilation) • Bottom cable entry (top entry on request) • RC series racks - heavy duty capacitors - “special” capacitor switching contactors - fusegear and busbars per capacitor bank kvar at: 525V 400V type FMS14005 FMS18005 FMS22005 FMS28005 FMS32005 FMS40005 FMS... 81 104 128 162 186 232 20-40-80 20-40-40-80 20-40-80-80 40-80-80-80 40-40-80-80-80 40-40-80-80-80-80 expands to (kvar) 400 400 400 400 400 – dimensions (mm) price (H) (W) (D) 2200 2200 2200 2200 2200 2200 600 600 600 600 600 600 460 267 20-40-80-80-80-80-80 800 2200 600 FMS46025 540 313 20-40-6x80 800 2200 600 FMS54025 620 360 20-40-7x80 800 2200 600 FMS62025 680 394 40-8x80 800 2200 600 FMS70025 800 464 40-40-9x80 – 2200 600 FMS80025 Made up by combining two/three panels with one controller operating all capacitor banks * Above prices do not include VAT. E&OE * * * * * 140 180 220 280 320 400 steps (kvar) at 525V 500 61265.00 500 71980.00 500 80010.00 500 93460.00 500 102400.00 500 121140.00 500 500 500 500 500 156140.00 175430.00 194180.00 207620.00 235860.00 F-10 Power quality & efficiency Power factor systems (automatic) 525V Made in Germany Power capacitors Three-phase industrial cylindrical capacitors w ne MKPg-275 capacitors are dry gas filled, protecting the windings from environmental influences with extended life expectancy, permitting mounting in any position. Gas used is inert and completely harmless to the environment. • Rated voltage: • Capacitance tolerance: • Dielectric losses: • Duty: • Maximum permissible current: • Protection: • Standards: 275.525-701400 type 440 or 525V 50Hz three-phase -5 ~ +10% <0.2 W/kvar continuous 1.5 ~ 2 In Overpressure disconnection facility IEC/EN 60831, VDE 0560-46/47, CSA C22.2 No. 190M1985, UL, GOST kvar at: In 440V 400V 3 x (A) Cn dimensions (mm) description price 3 x (μF) (H) (W) Three-phase cylindrical capacitors (440V) • M12 base mounted fixing stud (can be mounted horizontally) • Capacitors up to 15kvar supplied with discharge resistors (above 15kvar require discharge module) 275.186-516600 275.525-701400 2.5 2 3.3 14 3-ph 440V cyl capacitor 164 60 739.00 275.526-502800 5.0 4 6.6 28 3-ph 440V cyl capacitor 230 60 797.00 275.545-504000 7.5 6 10 40 3-ph 440V cyl capacitor 164 75 908.00 275.546-505700 10 8 14 57 3-ph 440V cyl capacitor 230 75 990.00 275.546-506800 12.5 10 16 68 3-ph 440V cyl capacitor 230 75 1053.00 275.556-508200 15 12.5 20 82 3-ph 440V cyl capacitor 30 85 1207.00 275.166-511100 20 15 27 111 3-ph 440V cyl capacitor 230 95 1622.00 275.176-513700 25 20 33 137 3-ph 440V cyl capacitor 230 100 1788.00 275.186-516600 30 25 40 116 3-ph 440V cyl capacitor 230 116 2053.00 275.389-522100 40 30 53 221 3-ph 440V cyl capacitor 280 116 2437.00 Three-phase cylindrical capacitors (525V) • M12 base mounted fixing stud (can be mounted horizontally) • Capacitors up to 15kvar supplied with discharge resistors (above 15kvar require discharge module) 275.526-801900 5 3 5.5 19 3-ph 525V cyl capacitor 230 60 853.00 275.546-703803 10 6 11 38 3-ph 525V cyl capacitor 230 75 1007.00 275.556-705800 15 9 17 58 3-ph 525V cyl capacitor 230 85 1195.00 275.176-707700 20 12 22 77 3-ph 525V cyl capacitor 230 100 1708.00 275.189-811503 30 18 33 115 3-ph 525V cyl capacitor 280 116 2323.00 275.398-715401 40 23 44 154 3-ph 525V cyl capacitor 245 136 2925.00 Accessories for cylindrical capacitors Discharge modules for above capacitors 20kvar and above • Simply plugs into capacitor connection terminal 275.100-10120 discharge resistor module for above capacitors 20~40kvar 26.00 275.398-715401 275.100-10120 Plastic protection caps Ø 275.157-10010 plastic protection caps for capacitor with diameters 85 49.00 275.167-10010 plastic protection caps for capacitor with diameters 95 51.00 275.177-10011 plastic protection caps for capacitor with diameters 100 60.00 275.187-10012 plastic protection caps for capacitor with diameters 116 69.00 275.157-10010 F-11 Above prices do not include VAT. E&OE ECOsine Active harmonic filters w ne FN3420... Multiple functions: harmonic filtering - reactive power compensation - load balancing Reliability and efficiency are important to business operation. This includes reliable operation of machines, manufacturing systems, and office equipment. Nevertheless, this is frequently not the case and often there is no obvious reason, despite the use of UPS and back-up generators. Unlike passive harmonic filters, these filters can provide harmonic mitigation under any load conditions up to their rated capacity. • • • • • • Global or selective compensation of harmonic currents up to the 50th order (reduces THID to 1.5% - 3%) Compensation of displacement power factor Load balancing Response time: less than 300 μs Adapts to changing network topologies instantly Up to 5 units can be wired in parallel to increase overall system requirements type rated current 400V (A) phase ECOsine three wire active harmonic IP rating power loss (W) 380 - 480Vac ±10% dimensions (mm) price (H) (W) (D) (500-690Vac available on request) FN3420-50-480-3 50A 3 wire IP20 <1300 615 358 FN3420-120-480-3 120A 3 wire IP20 <2500 972 469 FN3420-200-480-3 200A 3 wire IP54 <5000 2105 808 FN3420-300-480-3 300A 3 wire IP54 <7500 2105 808 4-wire version available on request for triplen harmonic filtering eg. 3rd, 9th, 15th….orders 288 203632.00 412 297440.00 604 1084512.00 604 1255929.00 ECOsine passive harmonic filters ECOsine FN 3416 represent very compact “economy line” with THID performance of ≤10 % in conjunction with the VSD’s built in DC-link choke. Ideal for non-linear three-phase equipment with 6-pulse front end rectifier circuits. Sufficient to comply with EN61000-3-12 or IEEE-519 and other power quality standards. Schaffner ECOsine filters help to unburden electrical infrastructures from excess loading and heat caused by current harmonics, and therefore support better utilization of electric system capacity. Lower harmonics also reduce the risk of system resonances and potential downtime of sensitive electronic equipment. FN 3416 filters upgrade standard motor drives to “low-harmonic drives” quickly and easily. • • • • THID performance of <10% (5% available on request) Compact design - Quick installation Efficient: >98% nominal line voltage and power Conformity to: UL508, EN61558-2-20, CE (LVD2006 / 95 / EC) type rated current 400V (A) rated load power (kW) 400V 500V power loss (W) dimensions (mm) price (H) (W) (D) FN3420-200-480-3 FN3416-45-33 45A 22 FN3416-60-34 60A 30 FN3416-75-34 75A 37 FN3416-110-35 110A 55 FN3416-150-40 150A 75 Larger sizes up to 200kW available on request EMC/RFI filters 30 37 45 75 90 306 408 410 546 784 455 520 520 580 700 280 280 280 280 450 230 46712.00 248 53524.00 248 62672.00 248 87195.00 385 102084.00 three-phase filters Electro Magnetic Interference (EMI) unwanted high frequencies which ride on the AC waveform. Many products such as variable frequency drives generate EMI, which may interrupt, obstruct, degrade or limit the effective performance of electronic equipment. FN3416-45-33 • • • • • • Max. continuous operating voltage: 480/277Vac Exceptional attenuation performance from 150kHz to 30Mhz Excellent saturation resistance up 50 meters cable length Most compact and slim filter design in its class Increases the immunity of the equipment being protected Compliance with class A according to EN 55011 type FN3258-16-44 Above prices do not include VAT. E&OE FN3258-16-44 FN3258-30-33 FN3258-42-33 FN3258-55-34 FN3258-75-34 FN3258-100-35 FN3258-130-35 FN3258-180-40 rated current 50°C typical drive size leakage current 400V power loss (W) 16A 30A 42A 55A 75A 100A 130A 180A 7.5kW 15kW 22kW 30kW 37kW 55kW 75kW 90kW 33.0 mA 33.0 mA 33.0 mA 33.0 mA 33.0 mA 33.0 mA 33.0 mA 33.0 mA 6.1 11.8 15.7 25.9 32.2 34.5 43.1 58.3 dimensions (mm) (H) (W) (D) 250 270 310 250 270 270 270 380 45 50 50 85 80 90 90 120 price 70 3374.00 85 3949.00 85 4622.00 90 5567.00 135 7093.00 150 8659.00 150 10285.00 170 13352.00 F-12 Power quality & efficiency Active / Passive harmonic filters UPS (uninterruptible power supplies) Single Phase UPS’s w ne Socomec single phase Uninterruptible Power Supplies meet all requirements for a high quality, reliable, faultless electrical supply to cover a very wide range of applications for every sector of the market. type supply load VA Watts output sockets NETYS PE 600 to 2000 VA NPE... • • • • • back-up dimensions (mm) description price time (H) (W) (D) VI “line interactive” with AVR step wave Clean output with Automatic Voltage Regulation Reduces battery ageing Protects data line (Tel/Internet/xDSL/LAN) from surges Delivered with user-friendly software Wide input range: 170 - 280 V Output: 230 V ±10% NPE-B600 NPE-0650 NPE-0850 NPE-1000-LCD NPE-1500-LCD NPE-2000-LCD 600 650 850 1000 1500 2000 360 360 480 600 900 1200 4 (IEC 320) 4 (IEC 320) 4 (IEC 320) 4 (IEC 320) 6 (IEC 320) 6 (IEC 320) NETYS PR 1000 to 2000 VA 15 min 15 min 20 min 45 min 55 min 60 min single phase single phase single phase single phase single phase single phase 145 145 145 165 205 203 100 100 100 145 145 145 290 290 290 345 390 390 1273.00 1471.00 2138.00 3411.00 4658.00 5511.00 145 145 145 345 390 390 5202.00 7302.00 9848.00 VI “line interactive” with AVR sine wave Solution for professional and IT equipment. NPR...MT • • • • • Sine wave output Clean output with Automatic Voltage Regulation Reduces battery ageing Protects data line (Tel/Internet/xDSL/LAN) from surges Wide input range: 170 - 280 V Output: 230 V ±10% Mini Tower NPR-1000-MT NPR-1500-MT NPR-2000-MT 1000 1500 2000 700 1050 1400 4 (IEC 320) 6 (IEC 320) 6 (IEC 320) 45 min 55 min 60 min single phase single phase single phase 165 205 203 Rack/Tower versatile, convertible • Optional battery extension modules to meet all back-up time requirements, even after installation • RS232 advanced connection for management of power supply and local/remote shutdown NPR-1700-RT NPR-2200-RT NPR-3300-RT 1700 2200 3300 1350 1800 2700 8 (IEC 320) 8 (IEC 320) 8 (IEC 320) Battery extensions NPR-B1700-RT 1700 NPR-B3300-RT 3300 NPR...RT NETYS RT 1100 to 11000 VA 87 87 87 440 440 440 436 10972.00 608 14777.00 608 19299.00 extension battery for 1700 VA UPS 6919.00 extension battery for 2200 and 3300 VA UPS 13134.00 VFI “online double conversion” True online double conversion Ready for 1+1 redundant mode Extensive configurability Easy to maintain Ready for LAN connection Versatile product (rack/tower configuration) LOCAL VIEW: UPS monitoring and shutdown point-to-point for Windows, Linux and Mac OS X MODBUS/JBUS RTU (RS232) RT-VISION: professional WEB/SNMP interface for UPS monitoring/shutdown management Rack/Tower versatile, convertible NRT2-5000K 5000 4500 NRT2-7000K 7000 5400 NRT2-9000K 9000 7200 NRT2-11000K 11000 9000 F-13 single phase single phase single phase Complete solution for IT infrastructures. Online double conversion technology with sinusoidal waveform, completely filters out all disturbances from / to mains power supply. • • • • • • • • • NRT2... 6 min 8 min 6 min Battery extensions NRT-B7000 7000 NRT-B11000 11000 terminals terminals terminals terminals 8 min 6 min 8 min 6 min single phase single phase single phase single phase 178 178 262 262 440 440 440 440 670 670 623 623 45307.00 54783.00 69993.00 78431.00 extension battery for 5000 and 7000 VA UPS 18595.00 extension battery for 9000 and 11000 VA UPS 23401.00 Above prices do not include VAT. E&OE 18 series - New generation occupancy sensors w ne • • • • • • • Extensive sensing area up to 120m2 Incorporates two sensors “presence” for zones of low activity and “movement” for transit areas Modern design Quick installation through push-in terminals 10A 1 NO “zero cross” switching Supplied with all hardware for recess mounting into wall boxes, suspended ceilings or surface mount Adjustable settings: light on time (since last detection) 12s~35 min sensitivity adjustment lux setting (ambient light intervention threshold) 0~500 lx type 18.41 switching current supply voltage 18.41 passage way sensor switching load (AC1) description price (Ø) 84 x (D) flush: 44 / surface: 85 mm For use in rectangular areas such as hotel lobbies, corridors, offices and walkways. The use of a special lens combined with electronics, provide a total sensing zone of 30 meters long by 4 meters wide. • Hotel and office corridors, transit areas • Sensing area 30 meters length and 4 meters width 184182300300 10A 100~230Vac 18.51 ceiling mount sensor 2.500 VA occupancy sensor for corridors 1300.00 (Ø) 84 x (D) flush: 35 / surface: 76 mm Responds to very small movements, suitable for use in offices, schools, and the workplace. The lens has been developed to achieve two zones of different sensitivity: Zone 1: overall area of 8 x 8 meters sensitive to normal movement Zone 2: central area of 4 x 4 met senses “body presence” by detecting very small movements 18.51 • Offices, schools zones of low activity • Two sensing areas: “presence” and “movement” detection • Sensing area 360° 185182300300 10A 100~230Vac 18.61 wall mount sensor 18.61 2.500 VA occupancy sensor for offices 1064.00 (Ø) 85 x (D) flush: 28 mm Latest evolution in movement detector techniques, featuring a wide viewing angle of 180° designed for fitting in new or existing wall boxes as a direct replacement of a wall mounted light switch or push-button. • Specific product for wall mounting to replace standard light switches • Wide angle sensing 180° 186182300300 10A 100~230Vac 2.500 VA wall mount occupancy sensor 1536.00 Movement detectors (economic version) Compact, economical movement detector for internal installations, these sensors detect movement in common areas and operate lights when required in low ambient areas. 18.21 • • • Ceiling mounting (compact) Wide angle of survey 360° Adjustable settings: (8 x 5 met detection at 2.8 met high) “light on” time (since last detection) 10s~12 min lux setting (ambient light intervention threshold) 5~350 lx 18.21 surface mount sensor 182182300000 10A 120~230Vac 18.31 flush mount sensor 183182300000 10A (Ø) 75 x (D) 50.5 mm 2.500 VA surface mnt movement detector 690.00 (Ø) 80 x (D) flush: 2 mm 120~230Vac 2.500 VA surface mnt movement detector 690.00 18.31 Above prices do not include VAT. E&OE F-14 Power quality & efficiency Occupancy sensors Occupancy sensors Occupancy sensors • • • • • Detect movement Measure ambient light Automatically switch lights “on” (if ambient is below pre-set level and movement is detected) Automatically switch lights “off” (if no movement is detected after a pre-set time delay period) Complies with: IEC 60669-1 and IEC 60669-2-1 - supply voltage: 230Vac 50Hz - switch current: 8/10/16A 230V (AC1) - lux adjustment: 5 - 1000 lux EE804 and EE805 motion detectors EE804 and EE805 are 360° indoor movement detectors with a built-in light sensitive switching function. Ideal for use in interior circulation areas such as corridors, entrance halls, bathrooms etc. EE804 - Operating time delay: - Detection range: type EE804 EE805 5s - 15 min 6 meter radius (at 2.5 meters high) 360° mounting surface flush rated price current description 105.5 mm dia. 75 mm hole economical motion detector economical motion detector 8A 8A 406.00 432.00 10A 546.00 EE820 basic motion detectors (IP55) Wall mounting with numerous mounting possibilities for indoor or outdoor applications. - Operating time delay: pulse, 5s -15 min - Detection range: 16 met frontal /8 met lateral (at 2.5 meters high) EE805 EE820 surface 140° wall mnt. basic occupancy sensor EE860 enhanced motion detectors (IP55) Offers vertical and horizontal adjustment and area limitation with shutters suitable for indoor or outdoor applications. Wall, inner/outer corner, ceiling mount. Setting and adjustments made via concealed potentionmeters or remote control. EE820 - Operating time delay: - Detection range: - Sensitivity adjustment: 5s - 15min 16met frontal / 10met lateral (at 2.5 meters high) 20% - 100% EE860 220° surface 16A 867.00 EE820 EE820 EE860 EE815/20 60.00 78.00 60.00 496.00 wall mnt. basic occupancy sensor Accessories EE825 EE827 EE855 EE806 corner mount accessory (inner/outer) ceiling mount accessory corner mount accessory (inner/outer) IR remote control for enhanced series High-performance combined presence and motion detector High-performance presence detectors combine detection of both presence and motion in an area ideally suited for offices where human presence is detected to maintain lighting level. Motion detection enhances the overall sensing range of the detectors. EE815 compact flush mount presence detector EE860 Compact super-flush device mounts through a 50mm hole for very neat installation. Settings and adjustments made via concealed potentiometers or remote control. - Operating time delay: - Detection range: 1 min - 1 hour presence 5 meter radius (at 2.5 meters high) motion 7 meter radius (at 2.5 meters high) EE815 60mm hole flush 360° enhanced presence detector 16A 1115.00 16A 2133.00 EE810 surface flush mount presence detector EE815 F-15 - Operating time delay: - Detection range: - Lux adjustment EE810 flush 1 min - 1 hour presence 7 meter radius (at 2.5 meters high) motion 13 meter radius (at 2.5 meters high) 5 - 1200 lux dual sens 360° enhanced presence detector Above prices do not include VAT. E&OE Notes Renewable energy