Instruction Manual for ®
8,000RPM Right-Angle Handpiece Model: RZ-15X Power Hand 2X controllers and handpieces combine to create the most versatile finishing system in the industry, offering rotary, profiling and belt sanding action.
Power Hand 2X component selection:
• Three controllers • Six straight (four standard, two slimline) and two angle rotaries
• Two reciprocating profilers • One side-to-side profiler • One belt sander • One 4:1 reduction gear • Separate motors and handpiece heads
255 Hancock Ave., Bridgeport, CT 06605, USA ☎ 1-203-366-5400 FAX 1-203-366-3953 Order toll-free 1-800-243-4466 Web site: gesswein.com E-mail:
[email protected] #890-1094/0311
#510-2120
Introduction
Notes
Gesswein Power Hand 2X Angle Rotary Handpieces are manufactured to the highest standards available to provide many years of trouble-free service. The direct current, electrically driven Angle Rotary Handpieces are designed to be used with Gesswein Power Hand 2X Single, Standard, Dual, Jewelers’ Micromotor, Power Carver II and Bright Cuffing Controllers. These Controllers Alternating Current to variable Direct Current (DC) by means of an I.C. “transistorized” automatically controlled circuit. The Gesswein Power Hand 2X handpiece series consists of nine models and eleven head assemblies with maximum operating speeds ranging from 8,000 to 55,000rpm and 0 to 117 strokes per second. All models are identified by their names, which are engraved on the motor housings.
Specifications Speed Range (RPM)
Dual or Single Controller* Standard Controller Input Voltage
0-15,000 1,500-15,000 3-30V DC
Max. Shaft Output (W/sec.)
Dual Controller Standard Controller Single Controller
49 44 33.8
Max. Stoppage Torque (ft.-lbs./N-m**)
Dual Controller Standard Controller Single Controller Net Wt. (without power cord)
0.065/0.088 0.058/0.078 0.053/0.072 13 oz.
*Or Standard Controller with variable-speed foot rheostat **Foot-pounds/Newton-meters
2
15
Notes
1. Accessories Included Accessories A. One 3.0mm Collet (reorder #501-0106) B. One 1⁄ 8" (3.2mm) Collet (reorder #501-0105) C. Two Carbon Brushes (reorder #510-0163) D. One Collet Wrench (reorder #510-0180) E. One Assortment of Tool Holders, PSA Chips and Felt Pads
Optional Accessories A. Handpiece Extension Cord (#510-1120): adds 6 feet, or almost 2 meters, to the 1.7-meter rotary handpiece cord B. Handpiece Cradle Rest (#510-1130): provides a safe holding place for the rotary handpiece when not in use C. Variable-Speed Foot Rheostat (#510-3100) D. On/Off Foot Switch (#510-3105) E. Reducing Collets: 1⁄ 8" to 3⁄ 32" (#816-1501), 1⁄ 8" to 1⁄ 16" (#816-1502), 3 ⁄ 32" to 1⁄ 16" (#816-1503), 3mm to 3⁄ 32" (#816-1504), 3mm to 1⁄ 16" (#816-1505)
2. Parts Nomenclature 1. Collet
5. Motor Case
2. Gear Housing
6. Motor Cover
3. Collet Release Ring
7. Strain Relief
4. Motor Connecting Ring
8. Electric Cord with 3-pin plug
2
4
3
5
6
8
1
Fig. 1 3
7
3. General Use Tool Changing The Gesswein Power Hand 2X Angle Rotary Handpiece uses a quick-tool-release mechanism that allows for rapid tool changes. To operate, turn the Collet Release Ring counterclockwise toward the arrow pointing to the “R” or release position (see fig. 2). When in the full “R” position, the Collet Release Ring will make a click sound; the collet is then fully open and ready to accept a tool.
Secure Release
Fig. 2
To secure the tool, turn the Collet Release Ring toward the “S” or secure position. Again, a click sound will be heard, indicating the collet is fully closed and the tool is secure. When changing tools, be sure that the handpiece motor is not running. If you attempt a tool change under this condition, the motor will be stalled and damage will occur.
Secure
S R
Release
Collet Removal The Angle Rotary Handpieces can accept many different size collets (see Specifications). Standard sizes are 3⁄ 32" (2.35mm) and 1⁄ 8" (3.2mm). To change collets, turn the Collet Release Ring to the full “R” position and remove the tool in the collet. Hold the collet between the thumb and forefinger and turn in a counterclockwise direction until the collet is removed (see fig. 3). Insert the new collet and reverse the procedure. It is best to always tighten a replaced collet by hand using the Collet Wrench (#510-0180), securing until just tight.
4
Fig. 3
13
RZ-15X Parts List, continued When ordering spare parts, always specify part# (or item# if applicable) and description. Part#
Item#
Description
RZ-15X-101
Motor Case
RZ-15X-102
Head Screw
RZ-15X-103
Rubber O-Ring
RZ-15X-104
Spacer
RZ-15X-105
Spacer Wave Washer
RZ-15X-106 RZ-15X-200
510-2304
RZ-15X-201
510-3087
Armature Complete Ball Bearing
RZ-15X-202
Spacer
RZ-15X-203
Spacer
RZ-15X-204
510-2305
Armature
RZ-15X-205
510-3073
Ball Bearing
RZ-15X-301
Rubber O-Ring
RZ-15X-302
Spacer
RZ-15X-303 RZ-15X-304
Rear Lid 510-0163
Carbon Brushes (one set)
RZ-15X-305
(+) Terminal Plate
RZ-15X-306
Brush Side Lid
RZ-15X-307
(–) Terminal Plate
RZ-15X-308 RZ-15X-309
Pan Head Screw 510-0167
Motor Cord with Plug
RZ-15X-310
Motor Cover
If the collet cannot be loosened by hand using the Collet Wrench, additional torque may be required. To use the Collet Wrench, place the triangular cutout in the wrench over the collet and turn counterclockwise to loosen and clockwise to tighten the collet. If more torque is required, hold the handpiece with the Collet Wrench secure on the collet, and tap the wrench with a solid tool (see fig. 3a) in a counterclockwise direction. This procedure will loosen the collet, which can then be removed by hand. If the collet is so tight that the above procedure will not loosen it, then remove the Head Assembly from the Motor Assembly. This can be done by grasping the Motor Connecting Ring (see fig. 1) and pulling upward. Insert the Chuck Joint Wrench (see fig. 3b) into the Nylon Coupler (#510-0151), hold the Head Assembly and Wrench securely in one hand, and with the Collet Wrench in place on the collet, loosen in a counterclockwise direction (for parts drawing, refer to page 11). After a collet is replaced, be sure that the Collet Release Ring is rotated to its full “S” position and that the collet rotates freely when turned by hand. If the collet does not rotate freely, it is not fully seated in the Head Assembly, and you must repeat the removalreplacement procedure.
Fig. 3a
R Loosen
Collet Wrench
Tighten
Chuck Joint Wrench
Fig. 3b
12
5
4. Operating Procedure with Standard Controller With your Angle Rotary Handpiece fitted with a selected tool, connect the Gesswein Power Controller to an electrical supply and the handpiece to one of the two output sockets provided. Set the Slide Rheostat on the Controller to “Low” or the “0” position. Put the Controller Main Switch to the “ON” position, which lights up a pilot light that indicates your rotary handpiece is ready to use. To increase the speed of the rotary handpiece, move the Slide Rheostat toward “High” or “10.” You can then begin working. When work is completed, put the Power Switch to “OFF.” To operate your rotary handpiece using the optional Variable-Speed Foot Rheostat or optional On/Off Foot Switch, please refer to the Power Hand 2X Controller Instruction Manual for proper connection. The handpiece will not rotate until the foot rheostat/switch is depressed. The rheostat provides infinitely variable speed control; the switch only turns handpiece on and off (operates at speed selected on control unit).
6
11
RZ-15X Parts List
5. Precautions
When ordering spare parts, always specify part# (or item# if applicable) and description. Part#
Item#
Description
Z-ANX-100
Name Plate
Z-ANX-101
Cap
Z-ANX-102
Retainer
Z-ANX-103
Set Ring
Z-ANX-104
Roller
Z-ANX-105
Roller Shaft
Z-ANX-106
Coil Spring
Z-ANX-107
Ball Bearing Case
Z-ANX-108
Pan Head Screw
Z-ANX-109
Lock Nut
Z-ANX-110
Housing
Z-ANX-111
Coil Spring Cover
Z-ANX-112
Coil Spring
Z-ANX-113
Lock Ring
Z-ANX-114
Coupler
Z-ANX-115
Stainless Steel Ball
Z-ANX-116
Slip Protection Grip
Z-ANX-200
Sub Drive Shaft Complete, 3⁄ 32"
Z-ANX-201
Sub Drive Shaft Complete, 3mm
Z-ANX-202
Sub Drive Shaft Complete, 1⁄ 8"
Z-ANX-211
Flange Screw
Z-ANX-212
Coil Spring
Z-ANX-213
C-Ring
Z-ANX-214
Wave Washer
Z-ANX-215
Ball Bearing
Z-ANX-216
Bearing Spacer
Z-ANX-217
Sub Drive Shaft
Z-ANX-218
Dust Seal A
Z-ANX-219
Spacer
Z-ANX-220
Spacer
Z-ANX-221
Dust Collar A
Z-ANX-222
Dust Collar B
Z-ANX-223
C-Ring
Z-ANX-224
501-0100
Collet, 3⁄ 32" (2.35mm)
Z-ANX-225
501-0106
Collet, 3mm
Z-ANX-226
501-0105
Collet, 1⁄ 8" (3.175mm)
Z-ANX-300
Drive Shaft Complete
Z-ANX-301
Drive Shaft
Z-ANX-302
Dust Collar
Z-ANX-303
Spacer
Z-ANX-304
Bearing Spacer B
Z-ANX-305
Coil Spring
Z-ANX-306
Spacer
Z-ANX-307 Z-ANX-308
Wave Washer 510-0151
A. Before operating your Handpiece, be sure that the Collet Release Ring is in the “S” or secure position. Failure to do so will result in a locked rotor condition and will cause the motor to stall. Motor damage will probably occur. B. Do not attempt to change tools or rotate the Collet Release Ring while the handpiece is running. This action will stop the motor abruptly, cause parts damage, and could also possibly cause motor damage. C. Avoid stalling the motor during use by pushing too hard on the work tool or by exceeding the torque capacity of the handpiece motor. D. The Power Hand 2X Rotary Handpiece is designed not to overheat with normal use. It may be used continuously and will provide efficient, long-life performance if you apply just enough machining and polishing pressure to maintain full motor speed. E. The 3⁄ 32" (2.35mm), 1⁄ 8" (3.2mm) and 3.00mm collets are manufactured to accept 3⁄ 32", 1⁄ 8" and 3.0mm ± 0.0008" shanked tools, respectively. Only use tools that correspond to the collet size being used. F. Do not use your handpiece in water or oil, and never allow any oil, water or other fluids, dirt or wood dust to enter the inner casing of the Head Assembly. Failure to keep foreign matter out of the inner casing will cause damage to the ball bearing assemblies. G. Do not subject the handpiece power cord to sharp bending or rough treatment. Such treatment could break the cord wires or damage the male or female cord connectors. H. To remove the handpiece motor cord, unscrew the motor cover to expose the male connector, then pull the cord straight back. Do not wiggle it back and forth. I. Do not point the handpiece at any part of the body while it is running, particularly during startups. J. Be careful when using Wire Burnishing Tools. The ends of these tools are made of piano wires that flare out during use. Never use these tools at speeds faster than 14,000-15,000rpm. Should speeds exceed these recommended guidelines, wires may come free from the hub and cause bodily damage.
Nylon Coupler (Joint)
Z-ANX-309
C-Ring
10
7
6. Maintenance Replacement of Carbon Brushes
Dust Removal
The motors in the Angle Rotary Handpieces use a spring tension-type carbon brush assembly. The approximate life of these brushes is 800-1,000 hours. Use the set of two replacement carbon brushes supplied with your handpiece when it becomes necessary to replace worn brushes. (Brushes should be changed when handpiece is not running at maximum speed, or if it sounds as though it’s running out of gas.) Please note that in the event you must change the brushes, it is important that both be replaced at the same time. Replacement of only one carbon brush will cause motor damage.
From time to time, it will be necessary to clean excessive dust that accumulates in the motor cover. To remove this dust, unfasten the handpiece Motor Cover by turning it in a counterclockwise direction. If compressed air is available, use it inside the cover and the motor armature air cooling vent. If air is not available, remove excessive dust with a dry brush. If necessary, use a cloth moistened with detergent to clean the cover, and blow into the air cooling vents to clean around the armature. Do not use any volatile liquid as a cleaner (i.e. paint thinner or alcohol). Periodically cleaning the inner threads on handpiece collets will ensure easy collet removal when changing sizes. Twist a clean rolled-up piece of tissue paper in and out of the threaded area.
To replace worn carbon brushes, shut off main power supply. Disconnect the Motor Cover by unscrewing it in a counterclockwise direction. The motor brushes are now exposed. The worn brush assemblies can be removed by using a small Phillips head screwdriver on the screws that secure the assemblies (see fig. 4). The brush spring mount will push the assembly out of the well so that it can then be lifted clear. The two new carbon brushes should be installed by gently pushing them into the brush well. When each assembly has been securely attached, replace the Motor Cover and Power Cord.
Lubrication Lubrication of your Gesswein Power Hand 2X Rotary Handpiece is not necessary, and you should not let oil or other fluids enter the Head Assembly (see Precautions, 5F).
Carbon Brush
Screw
Loosen
Tighten
Motor Cover
Fig. 4 8
9