Transcript
POWERLINX 110 TB-MC
The Tannoy PowerLinx system - comprising of the PLA 305 5-Channel 300 Watt power amplifier, PLC 4.1 controller and volume control pot - is designed to simplify installations and provide the user with maximum flexibility in system design options. The multi-channel (MC) amplifier and controller are factory-mounted into one of Tannoy’s foreground subwoofers (powered by 100 Watts of the multi-channel amplifier) so that the heart of the system is discretely concealed in either the corner of a room, a flush mount sheet rock wall, or a ceiling tile. The system controls are easily accessible after installation.
110 SR-MC
Any Tannoy full range loudspeaker (mains) connects to the system’s 200 Watts of available power with spring clips to the 4 separate speaker-level outputs.
110CS-MC
This architecturally attractive and versatile system delivers dynamic performance with the great sound, and the superb efficiency of the powerful ProBash™ amplifier. PowerLinx. As easy as 1,2,3. Choose your sub. Choose your mains. Choose your source. Play!
108 TB-MC
POWERLINX
For advanced installations the PLC 4.1 Controller offers: configuring systems in combinations of mono channels and stereo pairs; high pass - all pass, sub-line out for connections to other subwoofers or PowerLinx systems; VCA options for individual channel control; multiple loudspeakers (mains) on one speaker-level output (model dependent); and an optional 12’ controller-to-amplifier interconnect cable.
254mm 10"
SYSTEM Frequency Response +/- 3dB (CH 1-4)
(1)
(Sub Channel)
0.25dB 20Hz - 20kHz (switchable 120Hz high pass) 20Hz - 400Hz
Input Sensitivity (for rated output)
500mV
Subwoofer Crossover
18dB per octave @ 100Hz
Total System Power Output
300 Watts
Subwoofer
100 Watts
203mm 8"
TECHNICAL SPECIFICATIONS
PLA 305 AMPLIFIER
POWERLINX
Channels 1-4
6Ω channels 1-4 4Ω channels 1-4
50 Watts 50 Watts
PLC 4.1 CONTROLLER REAR SUB 1 2 3 4
0.25%, typically 0.15%
+10V MR
Protection
RFI, clip limiting , current limiting (short ckt. protection) no AC, no DC
Signal to Noise
-100dB from rated output Channels 1-4, Sub & Master (analog) VCA Master-optional VCA card for individual remote control of channels 1-4
Level Controls
CH 1 LEVEL
VCA Control Voltage
0-10 VDC for master level & optional VCA card
Indicators
Red "power" on LED on PLC 4.1 controller
Input Connections: PLC 4.1
Left & right balanced terminal block style Phoenix’ Euro Balanced 30kΩ Spring clip grip, 14 gauge
Speaker Connections: PLA 305 PLC 4.1 Output
OUT IN
UP = Full Frequency 2
1
3
4
DOWN = 80 Hz High Pass
230mm 9 1/16"
CH 2 LEVEL
CH 3 LEVEL
SIDE
Left and/or right inputs assignable to all outputs
LR LR L R L R L R
1 2 3 4 5 6 7 8 9 10
L = Left Input R = Right Input
FRONT
Input Matrix
Input Impedance
SUB 1 2 3 4
68mm 2 1/2"
THD (at rated output CH 1-4)
CH4 LEVEL
SUB LEVEL
MASTER LEVEL
LINE LEVEL ONLY LEFT INPUT
+
RIGHT INPUT
+
SUB LOOP OUT
+
SYSTEM CONFIGURATIONS REMOTE VOLUME (VCA) (OPTIONAL)
110 SUB W/PLA 305 AMPLIFIER
STEREO SOURCE LINE LEVEL
Terminal block style balanced 150Ω. Full bandwidth + 4dBu*
PLC 4.1
Preamp Cable (supplied)
8-pin DIN. Supplies connection from PLA 305 amp. to PLC4.1 controller. Length 30".
Power Requirements
120 Volt 60Hz AC 300VA
FULL-RANGE SPEAKERS
SUB-LOOP OUT (LINE LEVEL)
ACTIVE 110 SUB
2nd ZONE SUBWOOFER
*Output dependant on setting of master and sub level controls NOTES: A full range of measurements, performance data, and Ease Data can be downloaded from www.tannoy.com
ACCESSORIES
FEATURES
ARCHITECTURAL SPECIFICATIONS
€ PLM - 4 Mixer -four input mixer with ducking € VCA - VCA independent channel control plug in card € Potentiometer - 25kΩ wall pot for remote master volume € Set up cable - 12" interconnect cable € Zone Tap - convert stereo signal or mono speaker level to a mono line level signal
€ 300 W att 5-Channel amplifier € 100 Watts dedicated to Tannoy subwoofer, 4 - 50 Watt channels € Frequency response 20Hz to 20kHz - CH 1 - 4 € Frequency response 20Hz to 400Hz - CH sub € Controls for channels 1-4, sub and master level € Left and/or right input matrix assignable to all inputs € RFI, clip and current limiting protection € 25kΩ remote master volume control pot included € Architecturally concealed on/within subwoofer € VCA option for individual channel control
The PLA 305 amplifier shall consist of 300 Watts of power dedicated to 5-Channels and mount into one of Tannoy's foreground subwoofers via an 8" x 10" input panel. The amplifier will distribute 100 Watts of power to the foreground subwoofer and 50 Watts each to the remaining 4 channels. These channels will power Tannoy full range loudspeakers via a spring clip grip which accepts wires to 14 gauge. The amplifier shall incorporate RFI, clip and current limiting protection.
APPLICATIONS € • Foreground music systems € • Business music systems € • Retail outlets € • Reception / waiting rooms € • Boardrooms & offices € • Museums and interactive exhibits • Convention centers, hotels • €Cruise ships € • Houses of worship
The PLC 4.1 Controller will directly mount onto the PLA305 amplifier and connect to the amplifier via a supplied 30" 8-pin DIN cable. The controller shall have level controls for channels 1 through 4, sub-woofer and master. An optional VCA card shall be designed for individual channel remote level control. The input matrix shall have left and/or right assignable inputs for each amplifier channel. Input connections shall be left and right balanced terminal block style Phoenix Euro. Output connections shall be terminal block style 150Ω. Frequency response of the amplifier shall be 20Hz to 20kHz. The subwoofer crossover shall be 18dB per octave @ 100Hz. Sensitivity shall be 100mV for rated output. The system shall include a 25k potentiometer for remote master system VCA level control. The amplifier and controller shall be the Tannoy ... Powerlinx.
Tannoy United Kingdom
T: +44 (0) 1236 420199
F: +44 (0) 1236 428230
E:
[email protected]
Tannoy North America
T: (519) 745 1158
F: (519) 745 2364
E:
[email protected]
C69L.0603
POWERLINX
Tannoy operates a policy of continuous research and development. The introduction of new materials or manufacturing methods will always equal or exceed the published specifications which Tannoy reserves the right to alter without prior notice. Please verify the latest specifications when dealing with critical applications.