Notes  To Switch PoE Splitter 12vdc Power (Red and Black)    Pink and Tan To isolate the REX Motion use a REX motion with two form C relays and a built in timer. Wire the lock power through the NC contacts on relay 1 and the PowerNet input through the NO contacts on relay 2. Set the timer to drop power for egress. In DB Crystal set the PowerNet to accept the REX input but no unlatch. The exit button can be any secondary exit device. Simply wire the lock power through the NC relay. FA Interface is shown as a relay at the door in this drawing. Fuse shown is a .5 Amp Fast-Acting Fuse to isolate the power to the inside of the building. Littelfuse PN: 0208.500MXP, Fuse Holder 150274 To Common (Black) Lock Power + Red and Black Magnetic Lock Green and Black Isonas In Rush Suppressor Blue and Black NC Door Contact Other wires isolated and taped off FA Relay PowerNet RC Jumper Positions JP 1 JP 2 RJ-45 PowerNet – PoE Splitter w/Magnetic Lock, EDK, REX Motion, REX Button, DSM and FA Dwg No: Sheet 1 Date: Drawn By: Version: 4/13/15 Jason R Clement 1.00.00 4720 Walnut Street Boulder, CO 80301 www.isonas.com of 1