Preview only show first 10 pages with watermark. For full document please download

Powersafe Hr New Copy

   EMBED


Share

Transcript

EBT Euro-Batterietechnik GmbH Odyssey-Entladedaten PC310 - PC2250 PC310 performance data at 25°C, per module Watts Amps 1000 Watts or amps per PC310 100 10 1 0 .1 0 .0 1 0 .1 1 10 100 Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 738 473 312 236 191 139 98 76 41 28 21 17 11 9 5 80.8 43.2 26.0 19.0 15.0 10.8 7.6 6.0 3.2 2.3 1.8 1.4 0.9 0.8 0.4 Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 1182 786 517.2 390.6 316.2 230.4 165 129 70.2 48.5 37.3 30.5 19.9 16.3 9 112.0 71.9 46.3 34.5 27.7 20.0 14.2 11.0 5.9 4.1 3.1 2.5 1.7 1.3 0.74 Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 1361 648 415 313 254 187 136 107 60 42 32 26 17 14 7 128.1 64.4 39.6 29.2 23.5 16.9 12.2 9.6 5.3 3.7 2.9 2.3 1.5 1.2 0.7 Capacity Energy (Ah) (Wh) 2.7 3.6 4.4 4.8 5.0 5.4 5.7 6.0 6.5 6.8 7.0 7.2 7.6 7.8 8.6 24.6 39.4 53.1 59.0 62.9 69.3 73.9 76.4 81.0 82.8 83.7 84.5 86.1 86.8 90.5 ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg 613.2 393.3 259.4 196.0 158.4 115.1 81.8 63.5 33.7 22.9 17.4 14.0 8.9 7.2 3.8 20.4 32.8 44.1 49.0 52.3 57.6 61.4 63.5 67.3 68.8 69.6 70.2 71.5 72.1 75.2 273.3 175.3 115.6 87.4 70.6 51.3 36.5 28.3 15.0 10.2 7.8 6.3 4.0 3.2 1.7 9.1 14.6 19.7 21.8 23.3 25.7 27.4 28.3 30.0 30.7 31.0 31.3 31.9 32.2 33.5 H ours to 10 .0 2V @ 2 5ºC (77°F) PC535 performance data at 25°C, per 12V module Watts Watts or amps per PC535 1000 100 10 1 0 .1 ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg Amps 10000 0.1 0 .0 1 Capacity Energy (Ah) (Wh) 1 10 100 3.40 5.75 7.90 8.60 9.10 10.0 10.65 11.0 11.8 12.3 12.4 12.5 13.6 13.0 14.8 35.5 62.9 87.9 97.65 104.35 115.2 123.75 129.0 140.4 145.4 149.3 152.4 159.4 163.2 178.8 450.7 299.7 197.2 148.9 120.6 87.85 62.9 49.2 26.8 18.5 14.2 11.6 7.6 6.2 3.4 13.5 24.0 33.5 37.2 39.8 43.9 47.2 49.2 53.5 55.5 56.9 58.1 60.8 62.2 68.2 218.9 145.6 98.8 72.3 58.6 42.7 30.6 23.9 13.0 9.0 6.9 5.6 3.7 3.0 1.7 6.6 11.6 16.3 18.1 19.3 21.3 22.9 23.9 26.0 26.9 27.6 28.2 29.5 30.2 33.1 Hours to 10 .0 2V at 2 5ºC (7 7ºF ) PC545 performance data at 25°C, per 12V module Watts Watts or amps per PC545 1000 100 10 1 0.1 0 .1 ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg Amps 10000 0 .01 Capacity Energy (Ah) (Wh) 1 10 1 00 4.3 5.4 6.7 7.3 7.8 8.5 9.2 9.6 10.6 11.1 11.6 11.5 12.0 12.0 14.0 45.3 54.0 70.6 78.2 83.8 93.3 101.7 107.4 120.0 126.0 129.6 132.0 134.4 138.0 144.0 680.8 324.2 207.75 156.4 127.0 93.4 67.9 53.7 30.0 21.0 16.2 13.2 8.4 6.9 3.6 22.7 27.0 35.3 39.1 41.9 46.7 50.9 53.7 60.0 63.1 64.9 66.1 67.25 69.1 72.1 238.7 113.7 72.8 54.8 44.5 32.7 23.8 18.8 10.5 7.4 5.7 4.6 3.0 2.4 1.3 8.0 9.5 12.4 13.7 14.7 16.4 17.8 18.8 21.1 22.1 22.7 23.2 23.6 24.2 25.3 Hours to 10.02 V at 25 ºC (77 ºF ) 6 www.eurobatterietechnik.de Publication No: EN-ODY-AM-001 - May 2006 Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 1582 986 635 478 385 281 202 159 87 61 47 38 25 20 11 154.7 91.6 57.1 42.3 33.8 24.4 17.4 13.6 7.3 5.1 3.9 3.2 2.1 1.7 0.9 Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 1486 792 512 389 318 236 173 138 79 56 43 35 23 19 10 143.0 78.8 49.3 36.7 29.6 21.6 15.6 12.3 6.9 4.8 3.7 3.0 2.0 1.6 0.8 Capacity Energy (Ah) (Wh) ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg PC625 performance data at 25°C, per 12V module Watts 52.70 82.20 105.90 119.40 128.40 140.70 151.65 159.0 174.0 181.80 187.20 192.0 201.60 204.0 216.0 Capacity Energy (Ah) (Wh) 536.10 334.35 215.40 161.90 130.60 95.40 68.50 53.90 29.50 20.50 15.90 13.0 8.50 6.90 3.70 17.90 27.90 35.90 40.50 43.50 47.70 51.40 53.90 59.0 61.60 63.45 65.10 68.30 69.15 73.20 255.10 159.10 102.50 77.0 62.10 45.40 32.60 25.65 14.0 9.80 7.55 6.20 4.10 3.30 1.70 8.50 13.30 17.10 19.30 20.70 22.70 24.50 25.65 28.10 29.30 30.20 31.0 32.50 32.90 34.80 ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg Amps 10000 1000 Watts or amps per PC625 5.20 7.60 9.50 10.60 11.30 12.20 13.05 13.60 14.60 15.30 15.60 16.0 16.80 17.0 18.0 100 10 1 0.1 0 .0 1 0 .1 1 601.4 320.5 207.3 157.6 128.7 95.7 70.2 55.8 31.8 22.5 17.5 14.3 9.5 7.8 4.1 20.0 26.7 35.25 39.4 42.5 47.8 52.6 55.8 63.6 67.4 69.9 71.6 75.75 77.7 82.6 212.3 113.1 73.2 55.6 45.4 33.8 24.8 19.7 11.2 7.9 6.2 5.1 3.3 2.7 1.5 7.1 9.4 12.4 13.9 15.0 16.9 18.6 19.7 22.5 23.8 24.7 25.3 26.7 27.4 29.1 Amps 10000 1000 Watts or amps per PC680 49.5 66.0 87.1 97.4 104.9 118.2 130.1 138.0 157.2 166.5 172.8 177.0 187.2 192.0 204.0 100 PC680 performance data at 25°C, per 12V module Watts 4.8 6.6 8.4 9.2 9.8 10.8 11.7 12.3 13.8 14.4 14.8 15.0 16.0 16.0 16.0 10 Hours to 10 .0 2V at 2 5ºC (7 7ºF ) 100 10 1 0.1 0 .01 0 .1 1 10 1 00 Hours to 10.02 V at 25 ºC (77 ºF ) Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 2381 1446 954 726 592 436 316 250 138 96 74 61 40 32 17 224.8 142.8 90.6 67.4 54.2 39.2 28.1 21.9 11.9 8.3 6.4 5.2 3.4 2.8 1.5 Capacity Energy (Ah) (Wh) ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg PC925 performance data at 25°C, per 12V module Watts www.enersys.com 79.3 120.5 162.2 181.5 195.2 217.8 236.7 249.6 276.0 288.0 297.6 303.0 316.8 324.0 348.0 615.8 374.0 246.75 187.8 153.0 112.7 81.6 64.6 35.7 24.8 19.2 15.7 10.2 8.4 4.5 20.5 31.2 42.0 46.9 50.5 56.3 61.2 64.6 71.4 74.5 77.0 78.4 81.9 83.8 90.0 201.8 122.5 80.9 61.5 50.1 36.9 26.75 21.2 11.7 8.1 6.3 5.1 3.4 2.75 1.5 6.7 10.2 13.7 15.4 16.5 18.5 20.1 21.2 23.4 24.4 25.2 25.7 26.9 27.5 29.5 Amps 10000 1000 Watts or amps per PC925 7.5 11.9 15.4 16.9 17.9 19.6 21.1 21.9 23.8 24.9 25.6 26.0 27.2 27.5 30.0 100 10 1 0 .0 1 0 .1 1 10 100 Hours to 1 0.02V at 25 ºC (77ºF ) Publication No: EN-ODY-AM-001 - May 2006 7 PC1200 performance data at 25°C, per 12V module Watts Watts or amps per PC1200 1000 100 10 1 0 .1 Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 3580 1992 1338 1026 840 624 458 364 203 143 110 91 59 48 25 337.9 199.1 127.9 96.0 77.5 56.6 40.8 32.1 17.7 12.3 9.5 7.7 5.0 4.1 2.2 Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 5228 3337 2175 1644 1332 977 706 556 307 215 167 137 90 74 41 494.8 304.4 193.6 144.5 116.1 84.2 60.3 47.3 25.9 18.1 14.0 11.5 7.6 6.2 3.25 Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 5942 3636 2411 1833 1490 1091 786 615 333 229 175 142 90 73 37 569.8 337.6 218.5 163.8 132.6 96.0 68.6 53.6 28.9 19.9 15.2 12.4 8.0 6.5 3.4 Capacity Energy (Ah) (Wh) ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg Amps 10000 0 .0 1 Time 1 10 100 11.3 16.6 21.7 24.0 25.6 28.3 30.6 32.1 35.4 36.9 38.0 38.5 40.0 41.0 44.0 119.2 165.9 227.5 256.5 277.2 312.0 343.4 363.6 406.8 428.4 441.6 453.0 475.2 480.0 504.0 613.0 341.1 229.1 175.7 143.8 106.8 78.4 62.25 34.8 24.5 18.9 15.5 10.2 8.2 4.3 20.4 28.4 38.9 43.9 47.5 53.4 58.8 62.25 69.7 73.4 75.6 77.6 81.4 82.2 86.3 205.8 114.5 76.9 59.0 48.3 35.9 26.3 20.9 11.7 8.2 6.3 5.2 3.4 2.8 1.5 6.9 9.5 13.1 14.7 15.9 17.9 19.7 20.9 23.4 24.6 25.4 26.0 27.3 27.6 29.0 Hours to 10 .0 2V at 2 5ºC (7 7ºF ) PC1500 performance data at 25°C, per 12V module Watts Watts or amps per PC1500 1000 100 10 1 0 .1 ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg Amps 10000 0 .0 1 Capacity Energy (Ah) (Wh) 1 10 100 16.3 25.3 32.3 36.1 38.7 42.1 45.2 47.3 51.7 54.2 56.0 57.4 60.6 62.3 65.0 172.5 277.0 363.3 411.0 443.7 488.4 529.3 556.2 615.0 646.5 668.4 685.4 723.1 742.5 814.0 538.1 343.5 223.9 169.2 137.2 100.5 72.6 57.3 31.7 22.2 17.2 14.1 9.3 7.6 4.2 17.8 28.5 37.4 42.3 45.7 50.3 54.5 57.3 63.3 66.5 68.8 70.6 74.4 76.4 83.8 209.9 134.0 87.4 66.0 53.5 39.2 28.3 22.3 12.3 8.7 6.7 5.5 3.6 3.0 1.6 6.9 11.1 14.6 16.5 17.8 19.6 21.3 22.3 24.7 26.0 26.8 27.5 29.0 29.8 32.7 Hours to 10 .0 2V at 2 5ºC (7 7ºF ) PC1700 performance data at 25°C, per 12V module Watts Watts or amps per PC1700 1000 100 10 1 0 .1 ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg Amps 10000 0 .0 1 Capacity Energy (Ah) (Wh) 1 10 100 19.0 28.1 37.2 41.0 43.7 48.0 51.4 53.6 57.8 59.6 61.0 61.8 63.6 64.5 67.9 197.9 279.9 384.5 433.5 467.3 522.0 567.0 594.6 648.0 671.4 684.0 693.0 705.6 714.0 732.0 607.0 343.3 231.1 177.2 144.7 106.7 77.2 60.75 33.1 22.9 17.5 14.2 9.0 7.3 3.7 20.2 28.6 39.3 44.3 47.7 53.3 57.9 60.75 66.2 68.6 69.9 70.8 72.1 72.9 74.8 215.3 121.7 82.0 62.8 51.3 37.8 27.4 21.5 11.7 8.1 6.2 5.0 3.2 2.6 1.3 7.2 10.1 13.9 15.7 16.9 18.9 20.5 21.5 23.5 24.3 24.8 25.1 25.6 25.9 26.5 Hours to 10 .0 2V at 2 5ºC (7 7ºF ) 8 www.enersys.com Publication No: EN-ODY-AM-001 - May 2006 Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 7088 4755 3193 2448 2001 1482 1080 855 476 334 259 213 140 115 62 680.1 438.1 286.5 216.7 175.6 128.6 92.8 73.0 40.2 28.1 21.7 17.8 11.7 9.6 5.2 Capacity Energy (Ah) (Wh) ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg PC2150 performance data at 25°C, per 12V module W att s 233.9 394.7 533.2 611.9 660.4 741.2 810.1 855.5 952.7 1003.3 1037.4 1063.3 1118.4 1145.4 1243.2 520.6 349.2 234.5 179.7 147.0 108.9 79.3 62.8 35.0 24.6 19.0 15.6 10.3 8.4 4.6 17.2 29.0 39.2 44.9 48.5 54.4 59.5 62.8 70.0 73.7 76.2 78.1 82.1 84.1 91.3 207.9 139.4 93.6 71.8 58.7 43.5 31.7 25.1 14.0 9.8 7.6 6.2 4.1 3.4 1.8 6.9 11.6 15.6 17.9 19.4 21.7 23.8 25.1 27.9 29.4 30.4 31.2 32.8 33.6 36.5 Am ps 10000 1000 Watts or amps per PC2150 22.4 36.4 47.8 54.2 57.9 64.3 69.6 73.0 80.4 84.2 86.8 88.9 93.3 95.5 104.0 100 10 1 0 .0 1 0 .1 1 10 100 Hours to 10.02V at 25ºC (77ºF) Time Watts (W) Amps (A) 2 min 5 min 10 min 15 min 20 min 30 min 45 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 7090 4820 3291 2553 2107 1583 1170 937 536 382 299 247 165 137 76 671.6 443.8 296.4 227.1 185.8 137.9 100.9 80.2 45.2 32.0 25.0 20.6 13.8 11.4 6.3 Capacity Energy (Ah) (Wh) ENERGY AND POWER DENSITIES W/litre Wh/litre W/kg Wh/kg PC2250 performance data at 25°C, per 12V module Watts 236.1 401.5 559.5 638.3 695.3 791.5 877.5 937.0 1072.0 1146.0 1196.0 1235.0 1320.0 1370.0 1520.0 1143.0 301.2 205.6 159.5 131.7 98.9 73.1 58.6 33.5 23.9 18.7 15.4 10.3 8.6 4.75 14.75 25.1 35.0 39.9 43.5 49.5 54.8 58.6 67.0 71.6 74.7 77.2 82.5 85.6 95.0 181.8 123.6 84.4 65.5 54.0 40.6 30.0 24.0 13.7 9.8 7.7 6.3 4.2 3.5 2.0 6.1 10.3 14.4 16.4 17.8 20.3 22.5 24.0 27.5 29.4 30.7 31.7 33.9 35.1 39.0 Amps 10000 1000 Watts or amps per PC2250 22.4 37.0 50.4 56.8 61.3 69.0 75.7 80.2 90.4 96.0 100.0 103.0 110.4 114.0 126.0 100 10 1 0 .01 0 .1 1 10 100 H ours to 10 .0 2V at 25ºC (7 7ºF ) ODYSSEY storage and deep discharge recovery Figure 2: Open circuit voltage and state of charge For any rechargeable battery, storage and recharge are important criteria. This section provides some guidelines that will help you get the most from your ODYSSEY battery. Use Figure 2 to determine the SOC of the ODYSSEY battery, as long as the battery has not been charged or discharged for six or more hours. The only tool needed is a good quality digital voltmeter to measure its open circuit voltage (OCV)1. The graph shows that a healthy, fully charged ODYSSEY battery will have an OCV of 12.84V or higher at 25ºC (77ºF) 12.84V or higher indicates 100% SOC 12.8 Open circuit voltage (OCV), V (A) How do I know the state of charge (SOC) of the battery? 13.0 12.6 12.4 12.2 12.0 11.8 11.6 10 20 30 40 50 60 70 80 90 100 State of Charge (SOC), % 1 The OCV of a battery is the voltage measured between its positive and negative terminals without the battery connected to an external circuit (load). It is very important to take OCV reading only when the battery has been off charge for at least 6-8 hours, preferably overnight. www.enersys.com Publication No: EN-ODY-AM-001 - May 2006 9