PRE-SFP-B53-40 1.25Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM Product Features  Single-mode Bi-directional transmission at 1550nm, used as a pair with PRE-SFP-B35-40  1.25Gb/s Data Links up to 40 km on 9/125 µm SMF  MSA Package with Built-in WDM and LC receptacle  Hot-Pluggable  Single +3.3V Power Supply  Metal Enclosure, Excellent EMI ESD Protection  Isolation > 30 dB, Cross Talk < -45dB  Industrial (-40°C to 85°C), Extended (-5°C to 85°C) or Commercial (0°C to 70°C ) operating temperature Compliance Applications  SFF-8472 Compliant Monitoring Interface  Gigabit Ethernet  IEEE Std. 802.3z  Fibre Channel  RoHS compliant  WDM Applications  Class 1 Laser Safety per EN (IEC) 60825 regulations Description Precision Optical Transceivers PRE-SFP-B53-40 is a high performance, cost effective Bi-directional transceiver with a single LC optical interface and a built-in WDM for data communication applications. PRE-SFP-B53-40 operates at 1550 nm (Tx) and 1310 nm (Rx) nominal wavelengths and includes a standard AC coupled CML for high speed signal and LVTTL control and monitor signals. The DFB laser transmitter and IC driver with temperature compensation and automatic power control circuit makes the transmitter output power and extinction ration stable across the operating temperature range. The Receiver consists of an InGaAs photodiode and transimpedance with AGC for wide dynamic rage. A 21dB link budget ensures 1000Base Ethernet transmission up to 40 km. Absolute Maximum Ratings Parameter Storage Temperature Supply Voltage Relative Humidity Symbol Min. TS Max. Unit -40 +85 °C VCCT, R -0.5 4 V RH 0 85 % -40 85 -5 85 0 70 Industrial Case Operating Temperature Extended Commercial Top Typical ⁰C Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 1 PRE-SFP-B53-40 1.25Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM Recommended Operating Environment Parameter Symbol Min. Typical Max. Unit 0 +70 °C 3.0 3.6 V Industrial Case operating Temperature Extended TC Commercial Supply Voltage VCCT, R Power Supply Rejection 100 mVP-P Electrical Characteristics (TOP = 0 to 70 °C, VCC = 3.0 to 3.60 Volts) Parameter Symbol Min. Typical Max. Unit Supply Voltage Vcc 3.0 3.30 3.60 V Supply Current Icc 160 280 mA Inrush Current Isurge Icc+30 mA Maximum Power Pmax 1.0 W 110 Ω Note Transmitter Section: Input differential impedance Rin 90 Vin PP 200 1200 mVp-p Transmit Disable Voltage VD Vcc – 1.3 Vcc V Transmit Enable Voltage VEN Vee Vee+ 0.8 V 10 µs 1000 mV 3 Single ended data input swing Transmit Disable Assert Time Receiver Section: Single ended data output swing Tdessert Vout,pp 300 100 1 2 Data output rise time tr 150 ps 4 Data output fall time tf 150 ps 4 LOS Fault Vlosfault Vcc – 0.5 VCC_host V 5 LOS Normal Vlos norm Vee Vee+0.5 V 5 PSR 100 mVpp 6 51.7 ps 7 122.4 ps Power Supply Rejection Deterministic Jitter Contribution Total Jitter Contribution Notes: RXΔDJ RXΔTJ 1. AC coupled 2. Or open circuit 3. Into 100 Ohm differential termination 4. 20 – 80 % 5. LOS is LVTTL. Logic 0 = normal operation; logic 1 = no signal detected 6. All transceiver specifications are compliant with a power supply sinusoidal modulation of 20 Hz to 1.5MHz up to specified value applied through the power supply filtering network shown on page 23 of the Small Form-factor Pluggable (SFP) Transceiver MultiSource Agreement (MSA), September 14, 2000. 7. Measured with DJ-free data input signal. In actual application, output DJ will be the sum of input DJ and ΔDJ. Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 2 PRE-SFP-B53-40 1.25Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM Optical Parameters (TOP = 0 to 70 °C, VCC = 3.00 to 3.60 Volts) Parameter Symbol Min. Typical Max. Unit Note λc 1480 1550 1580 1 nm nm 1 0.0 dBm 2 160 ps 3 Transmitter Section: Center Wavelength Spectral Width(-20dB) Optical Output Power σ Pout Optical Rise/Fall Time tr / tf Extinction Ratio ER Deterministic Jitter Contribution Total Jitter Contribution Eye Mask for Optical Output Relative Intensity Noise -5.0 9 dB TXΔDJ TXΔTJ 56.5 119 ps ps 4 Compliant with Eye Mask Defined in IEEE 802.3 standard RIN -120 dB/Hz Receiver Section: Optical Input Wavelength Optical Input Power λ 1270 Pin -23 Receiver Reflectance Receiver Overload RX Sensitivity 1310 1360 nm -3 dBm 12 5.6 dB Pol -3 dBm 5.6 Sen -23 dBm 5.6 RX_LOS Assert LOS A RX_LOS Deassert LOS D RX_LOS Hysteresis LOS H -34 dBm 2 -24 dBm 2.5 dB 1250 Mb/s General Specifications BR Data Rate Bit Error Rate Max. Supported Link Length on 9/125μm [email protected] Total System Budget 1062 BER 10-12 LMAX 40 LB 21 km 7 dB 8 Notes: 1. Also specified to meet curves in FC-PI 13.0 Figures 18 and 19, which allow trade-off between wavelength spectral width. 2. Class 1 Laser Safety per FDA/CDRH and EN (IEC) 60825 regulations. 3. Unfiltered, 20-80%. Complies with IEEE 802.3 (Gig. E), FC 1x and 2x eye masks when filtered. 4. Measured with DJ-free data input signal. In actual application, output DJ will be the sum of input DJ and ΔDJ. 5. Measured with conformance signals defined in FC-PI 13.0 specifications. 6. Measured with PRBS 27-1 at 10-12 BER 7. Dispersion limited per FC-PI Rev. 13 8. Attenuation of 0.45 dB/km is used for the link length calculations. Distances are indicative only. Please refer to the Optical Specifications in Table IV to calculate a more accurate link budget based on specific conditions in your application. Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 3 PRE-SFP-B53-40 1.25Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM Digital Diagnostic Monitor Characteristics The following Digital Diagnostic characteristics are defined over the Recommended Operating Environment unless otherwise specified. It is compliant with SFF-8472 Rev10.2 with internal calibration mode. For external calibration mode please contact our sales. Parameter Temperature monitor absolute error Laser power monitor absolute error RX power monitor absolute error Supply voltage monitor absolute error Bias current monitor absolute error Symbol Min. Max. Unit DMI_Temp DMI_TX DMI_RX DMI_VCC DMI_Ibias -3 -3 -3 -0.1 -10% 3 3 3 0.1 10% degC dB dB V mA Block Diagram of Transceiver Figure 1: Block Diagram Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 4 PRE-SFP-B53-40 1.25Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM Pin Assignment Figure 2: Diagram of Host Board Connector Block Pin Numbers and Names Figure 3: SFP Host Board Mechanical Layout Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 5 PRE-SFP-B53-40 1.25Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM Figure 4: SFP Host Board Mechanical Layout (Continued) Pin Description Pin No 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Name VeeT TX Fault TX Disable MOD-DEF2 MOD-DEF1 MOD-DEF0 Rate Select LOS VeeR VeeR VeeR RDRD+ VeeR VccR VccT VeeT TD+ TDVeeT Function Transmitter Ground Transmitter Fault Indication Transmitter Disable Module Definition Module Definition 1 Module Definition 0 Not Connected Loss of Signal Receiver Ground Receiver Ground Receiver Ground Inv. Received Data Out Received Data Out Receiver Ground Receiver Power Transmitter Power Transmitter Ground Transmit Data In Inv. Transmit In Transmitter Ground Plug Seq Notes 1 3 3 2 3 3 3 3 1 1 1 3 3 3 2 2 1 3 3 1 2 3 3 3 4 5 1 1 1 6 6 1 1 6 6 Notes: 1. 2. 3. 4. 5. 6. Circuit ground is internally isolated from chassis ground. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V. Should be pulled up with 4.7k - 10 kohms on host board to a voltage between 2.0V and 3.6V.MOD_DEF(0) pulls line low to indicate module is plugged in. Rate select is not used LOS is open collector output. Should be pulled up with 4.7k – 10 kohms on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal. AC Coupled Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 6 PRE-SFP-B53-40 1.25Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM Recommended Circuit SFP Module Host Board VCC(3.3V) VCCT 4K7 to10KΩ TX_Disable TX_Fault Z=50Ω PECL Z=50Ω 100Ω Laser Driver Z=50Ω 100Ω PECL Z=50Ω Amplifer RX_LOS 4K7 to10KΩ VCC(3.3V) 3X4K7 to10KΩ MOD_DEF(2) MOD_DEF(1) EEPROM MOD_DEF(0) RGND Figure 5: SFP Host Recommended Circuit Serial ID Memory Contents Data Address Length (Byte) Base ID Fields 0 1 1 1 2 1 3-10 8 11 1 12 1 13 1 14 1 15 1 16 1 17 1 18 1 19 1 20-35 16 36 1 37-39 3 40-55 16 Name Description and Contents Identifier Reserved Connector Transceiver Encoding BR,Nominal Reserved Length(9µm,km) Length(9µm) Length(50µm) Length(62.5µm) Length(Copper) Reserved Vendor Name Reserved Vendor OUI Vendor PN Type of Serial transceiver (03h=SFP) Extended identifier of type serial transceiver (04h) Code of optical connector type (07=LC) Gigabit Ethernet 1000Base-BX 8B10B (01h) Nominal baud rate, unit of 100Mbps (0000h) Link length supported for 9/125µm fiber, units of km Link length supported for 9/125µm fiber, units of 100m Link length supported for 50/125µm fiber, units of 10m Link length supported for 62.5/125µm fiber, units of 10m Link length supported for copper, units of meters SFP vendor name: SFP transceiver vendor OUI ID Part Number Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 7 PRE-SFP-B53-40 1.25Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM 56-59 4 60-61 2 62 1 63 1 Extended ID Fields 64-65 2 Vendor rev Wavelength Reserved CCID Revision level for part number Laser wavelength Option Indicates which optical SFP signals are implemented (001Ah = LOS, TX_FAULT, TX_DISABLE all supported) Upper bit rate margin, units of % Lower bit rate margin, units of % Serial number (ASCII) Manufacturing date code 66 1 BR, max 67 1 BR, min 68-83 16 Vendor SN 84-91 8 Date code 92-94 3 Reserved 95 1 CCEX Vendor Specific ID Fields 96-127 32 Readable Least significant byte of sum of data in address 0-62 Check code for the extended ID Fields (addresses 64 to 94) Vendor specific date, read only Diagnostics Memory Contents (A2h) Data Address Length (Byte) Name Description and Contents Diagnostic and control/status fields 0-39 40 A/W Thresholds 40-55 16 Unallocated Diagnostic Flag Alarm and Warning Thresholds 56-91 16 Ext Cal Constants Diagnostic calibration constants for optional External Calibration 92-94 95 96-105 106-109 110 111 112-113 114-115 116-117 118-119 3 1 10 4 1 1 2 2 2 2 Unallocated CC_DMI Diagnostics Unallocated Status/Control Reserved Alarm Flags Unallocated Warning Flags Ext Status/Control Check code for Base Diagnostic Fields (addresses 0 to 94) Diagnostic Monitor Data (internally or externally calibrated) Optional Status and Control Bits Reserved for SFF-8079 Diagnostic Alarm Flag Status Bits Diagnostic Warning Flag Status Bits Extended module control and status bytes General use fields 120-127 128-247 248-255 8 120 8 Vendor Specific User EEPROM Vendor Control Vendor specific memory addresses User writable non-volatile memory Vendor specific control addresses Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 8 PRE-SFP-B53-40 1.25Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM Mechanical Dimensions Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 9