Preview only show first 10 pages with watermark. For full document please download

Pre-sfp10g-lrm Datasheet - Precision Optical Transceivers

   EMBED


Share

Transcript

PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM Product Features  10Gb/s serial optical interface  Electrical interface compliant to SFF-8431 for enhanced 8.5 and 10 Gigabit SFP  1310nm DFB transmitter, PIN photo-detector  2-wire interface compliant with SFF-8472 DDM  All-metal housing for superior EMI performance  Low power consumption  Cost effective 10G SFP solution enabling higher port densities and greater Bandwidth  Commercial (0°C to 70°C ) operating temperature Applications Compliance  IEEE Std. 802.3ae 10GBase-LRM  10G Ethernet switches and routers  RoHS compliant  10GE Storage  Class 1 Laser Safety per FDA/CDRH and EN  10G FC Storage (IEC) 60825 regulations  Inter Rack Connection  Other high speed data connections Description Precision Optical Transceivers PRE-SFP10G-LRM, 10Gb/s SFP (SFP+), transceivers support 10-Gigabit Ethernet links up to 220 m at 1310 nm wavelength over Multimode fiber. PRE-SFP10G-LRM module electrical interface is compliant with SFI electrical specifications. The transmitter converts 10Gb/s serial PECL or CML electrical data into serial optical data compliant with the 10GBASE-LRM standard. The receiver converts 10Gbit/s serial optical data into serial PECL/CML electrical data. Rx_LOS when high indicates an optical signal level below that specified in the relevant standard. This typically indicates to missing, broken cables or a disabled, failing or a powered off transmitter at the far end of the system. System Application: Application in the system. Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 1 PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM Absolute Maximum Ratings Parameter Symbol Min. Power Supply Voltage Storage Temperature Operating Case Temperature Relative Humidity RX Input Average Power VCC Tc Tc RH Pmax 0 -40 0 5 - Typical Max. Unit 3.6 85 70 95 0 V C C % dBm Recommended Operating Environment Parameter Power Supply Voltage Power Supply Current Operating Case Temperature Symbol Min. Typical Max. Unit VCC Icc TC 3.135 3.3 0 25 3.465 250 70 V mA C Electrical Characteristics (TOP = 0 to 70 °C, VCC = 3.0 to 3.60 Volts) Parameter Symbol Min. Typical Max. Unit Data Rate - 10.3125 - Gbps Power Consumption Transmitter Section: - 500 800 mW -0.3 - 4 V 15 - - mV Single Ended Output Voltage Tolerance Common mode voltage tolerance Tx Input Diff Voltage Tx Fault Data Dependent Input Jitter Data Input Total Jitter Receiver Section: VI 90 350 mV VoL DDJ TJ -0.3 0.4 0.1 0.28 V UI UI 4 V 425 mV Single Ended Output Voltage Tolerance Rx Output Diff Voltage Rx Output Rise and Fall Time -0.3 Vo 150 Tr/Tf 30 - ps Total Jitter TJ 0.7 UI Deterministic Jitter DJ 0.42 UI Note At 0.7mA 20% to 80% Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 2 PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM Optical Parameters (TOP = 0 to 70 °C, VCC = 3.00 to 3.60 Volts) Parameter Symbol Min. Typical Max. Unit Center Wavelength λt 1260 1310 1360 nm RMS spectral width Pm - - Average Optical Power Pavg -7.3 - Optical Power OMA Poma - - Laser Off Power Poff - - -30 dBm Extinction Ratio ER 3.5 - - dB Transmitter Dispersion Penalty TDP - - 3.9 dB Relative Intensity Noise Rin - - -128 dB/Hz - - 12 dB λr 1260 1310 1360 nm Receiver Sensitivity (OMA) Stressed Sensitivity (OMA) Los Assert Psens LosA -30 - -11.1 -7.5 - dBm dBm dBm Los Dessert LosD - - -12 dBm Los Hysteresis LosH 0.5 - - dB Pin - - -1 dBm - - -12 dB Note Transmitter Section: Optical Return Loss Tolerance Receiver Section: Center Wavelength Overload Receiver Reflectance nm -1 1 dBm dBm 1 12dB reflection Notes: 1. Trade-offs between spectral width, center wavelength and minimum OMA are shown in the following Table. Timing Characteristics Parameter TX_Disable Assert Time TX_Disable Negate Time Time to Initialize Include Reset of TX_FAULT TX_FAULT from Fault to Assertion TX_Disable Time to Start Reset Receiver Loss of Signal Assert Time Receiver Loss of Signal Deassert Time Rate-Select Chage Time Serial ID Clock Time Symbol t_off t_on t_int t_fault t_reset TA,RX_LOS Td,RX_LOS t_ratesel t_serial-clock Min. Typical Max. 10 1 300 100 10 100 100 10 100 Unit µs ms ms µs µs µs µs µs kHz Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 3 PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM Digital Diagnostic Monitor Characteristics The following digital diagnostic characteristics are defined over the Recommended Operating Environment unless otherwise specified. It is compliant to SFF-8472 Rev10.2 with internal calibration mode. For external calibration mode please contact our sales stuff. Parameter Symbol Min. Max. Unit Temperature monitor absolute error DMI_Temp -3 3 ⁰C Laser power monitor absolute error DMI_TX -3 3 dB RX power monitor absolute error DMI_RX -3 3 dB Supply voltage monitor absolute error DMI_VCC -0.08 0.08 V Bias current monitor DMI_Ibias -10% 10% mA Block Diagram Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 4 PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM Application Schematics Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 5 PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM Pin Assignment Module Interface to Host Module Contact Assignment Pin Definition – SFP10G PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Logic LVTTL-O LVTTL-I LVTTL-I/O LVTTL-I LVTTL-I LVTTL-O LVTTL-I CML-O CML-O CML-I CML-I Symbol VeeT TX_Fault TX_Dis SDA SCL MOD_DEF0 RS0 RX_LOS RS1 VeeR VeeR RDRD+ VeeR VccR VccT VeeT TD+ TDVeeT Name / Description Module Transmitter Ground Module Transmitter Fault Transmitter Disable; Turns off transmitter laser output 2-Wire Serial Interface Data Line 2-Wire Serial Interface Clock Module Definition, Grounded in the module Receiver Rate Select Receiver Loss of Signal Indication Active LOW Transmitter Rate Select (not used) Module Receiver Ground Module Receiver Ground Receiver Inverted Data Output Receiver Data Output (not used) Module Receiver Ground Module Receiver 3.3 V Supply Module Receiver 3.3 V Supply Module Transmitter Ground Transmitter Non-Inverted Data Input Transmitter Inverted Data Input Module Transmitter Ground Note 1 2 2 1 1 1 1 1 Notes: 1. Module ground pins GND are isolated from the module case. 2. Shall be pulled up with 4.7K-10Kohms to a voltage between 3.15V and 3.45V on the host board Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 6 PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM Mechanical Dimensions Precision Optical Transceivers, Inc. PrecisionOT.com [email protected] Tel. 585-500-4090 7