PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM
Product Features
10Gb/s serial optical interface
Electrical interface compliant to SFF-8431 for enhanced 8.5 and 10 Gigabit SFP
1310nm DFB transmitter, PIN photo-detector
2-wire interface compliant with SFF-8472 DDM
All-metal housing for superior EMI performance
Low power consumption
Cost effective 10G SFP solution enabling higher port densities and greater Bandwidth
Commercial (0°C to 70°C ) operating temperature
Applications
Compliance
IEEE Std. 802.3ae 10GBase-LRM
10G Ethernet switches and routers
RoHS compliant
10GE Storage
Class 1 Laser Safety per FDA/CDRH and EN
10G FC Storage
(IEC) 60825 regulations
Inter Rack Connection
Other high speed data connections
Description Precision Optical Transceivers PRE-SFP10G-LRM, 10Gb/s SFP (SFP+), transceivers support 10-Gigabit Ethernet links up to 220 m at 1310 nm wavelength over Multimode fiber. PRE-SFP10G-LRM module electrical interface is compliant with SFI electrical specifications. The transmitter converts 10Gb/s serial PECL or CML electrical data into serial optical data compliant with the 10GBASE-LRM standard. The receiver converts 10Gbit/s serial optical data into serial PECL/CML electrical data. Rx_LOS when high indicates an optical signal level below that specified in the relevant standard. This typically indicates to missing, broken cables or a disabled, failing or a powered off transmitter at the far end of the system. System Application:
Application in the system.
Precision Optical Transceivers, Inc. PrecisionOT.com
[email protected] Tel. 585-500-4090 1
PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM
Absolute Maximum Ratings Parameter
Symbol
Min.
Power Supply Voltage Storage Temperature Operating Case Temperature Relative Humidity RX Input Average Power
VCC Tc Tc RH Pmax
0 -40 0 5 -
Typical
Max.
Unit
3.6 85 70 95 0
V C C % dBm
Recommended Operating Environment Parameter Power Supply Voltage Power Supply Current Operating Case Temperature
Symbol
Min.
Typical
Max.
Unit
VCC Icc TC
3.135
3.3
0
25
3.465 250 70
V mA C
Electrical Characteristics (TOP = 0 to 70 °C, VCC = 3.0 to 3.60 Volts) Parameter
Symbol
Min.
Typical
Max.
Unit
Data Rate
-
10.3125
-
Gbps
Power Consumption Transmitter Section:
-
500
800
mW
-0.3
-
4
V
15
-
-
mV
Single Ended Output Voltage Tolerance Common mode voltage tolerance Tx Input Diff Voltage Tx Fault Data Dependent Input Jitter Data Input Total Jitter Receiver Section:
VI
90
350
mV
VoL DDJ TJ
-0.3
0.4 0.1 0.28
V UI UI
4
V
425
mV
Single Ended Output Voltage Tolerance Rx Output Diff Voltage Rx Output Rise and Fall Time
-0.3 Vo
150
Tr/Tf
30
-
ps
Total Jitter
TJ
0.7
UI
Deterministic Jitter
DJ
0.42
UI
Note
At 0.7mA
20% to 80%
Precision Optical Transceivers, Inc. PrecisionOT.com
[email protected] Tel. 585-500-4090 2
PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM
Optical Parameters (TOP = 0 to 70 °C, VCC = 3.00 to 3.60 Volts) Parameter
Symbol
Min.
Typical
Max.
Unit
Center Wavelength
λt
1260
1310
1360
nm
RMS spectral width
Pm
-
-
Average Optical Power
Pavg
-7.3
-
Optical Power OMA
Poma
-
-
Laser Off Power
Poff
-
-
-30
dBm
Extinction Ratio
ER
3.5
-
-
dB
Transmitter Dispersion Penalty
TDP
-
-
3.9
dB
Relative Intensity Noise
Rin
-
-
-128
dB/Hz
-
-
12
dB
λr
1260
1310
1360
nm
Receiver Sensitivity (OMA) Stressed Sensitivity (OMA) Los Assert
Psens LosA
-30
-
-11.1 -7.5 -
dBm dBm dBm
Los Dessert
LosD
-
-
-12
dBm
Los Hysteresis
LosH
0.5
-
-
dB
Pin
-
-
-1
dBm
-
-
-12
dB
Note
Transmitter Section:
Optical Return Loss Tolerance Receiver Section: Center Wavelength
Overload Receiver Reflectance
nm -1
1
dBm dBm
1
12dB reflection
Notes: 1. Trade-offs between spectral width, center wavelength and minimum OMA are shown in the following Table.
Timing Characteristics Parameter TX_Disable Assert Time TX_Disable Negate Time Time to Initialize Include Reset of TX_FAULT TX_FAULT from Fault to Assertion TX_Disable Time to Start Reset Receiver Loss of Signal Assert Time Receiver Loss of Signal Deassert Time Rate-Select Chage Time Serial ID Clock Time
Symbol t_off t_on t_int t_fault t_reset TA,RX_LOS Td,RX_LOS t_ratesel t_serial-clock
Min.
Typical
Max. 10 1 300 100
10 100 100 10 100
Unit µs ms ms µs µs µs µs µs kHz
Precision Optical Transceivers, Inc. PrecisionOT.com
[email protected] Tel. 585-500-4090 3
PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM
Digital Diagnostic Monitor Characteristics The following digital diagnostic characteristics are defined over the Recommended Operating Environment unless otherwise specified. It is compliant to SFF-8472 Rev10.2 with internal calibration mode. For external calibration mode please contact our sales stuff.
Parameter
Symbol
Min.
Max.
Unit
Temperature monitor absolute error
DMI_Temp
-3
3
⁰C
Laser power monitor absolute error
DMI_TX
-3
3
dB
RX power monitor absolute error
DMI_RX
-3
3
dB
Supply voltage monitor absolute error
DMI_VCC
-0.08
0.08
V
Bias current monitor
DMI_Ibias
-10%
10%
mA
Block Diagram
Precision Optical Transceivers, Inc. PrecisionOT.com
[email protected] Tel. 585-500-4090 4
PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM
Application Schematics
Precision Optical Transceivers, Inc. PrecisionOT.com
[email protected] Tel. 585-500-4090 5
PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM
Pin Assignment
Module Interface to Host
Module Contact Assignment
Pin Definition – SFP10G PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Logic LVTTL-O LVTTL-I LVTTL-I/O LVTTL-I LVTTL-I LVTTL-O LVTTL-I
CML-O CML-O
CML-I CML-I
Symbol VeeT TX_Fault TX_Dis SDA SCL MOD_DEF0 RS0 RX_LOS RS1 VeeR VeeR RDRD+ VeeR VccR VccT VeeT TD+ TDVeeT
Name / Description Module Transmitter Ground Module Transmitter Fault Transmitter Disable; Turns off transmitter laser output 2-Wire Serial Interface Data Line 2-Wire Serial Interface Clock Module Definition, Grounded in the module Receiver Rate Select Receiver Loss of Signal Indication Active LOW Transmitter Rate Select (not used) Module Receiver Ground Module Receiver Ground Receiver Inverted Data Output Receiver Data Output (not used) Module Receiver Ground Module Receiver 3.3 V Supply Module Receiver 3.3 V Supply Module Transmitter Ground Transmitter Non-Inverted Data Input Transmitter Inverted Data Input Module Transmitter Ground
Note 1
2 2
1 1
1
1
1
Notes: 1. Module ground pins GND are isolated from the module case. 2. Shall be pulled up with 4.7K-10Kohms to a voltage between 3.15V and 3.45V on the host board
Precision Optical Transceivers, Inc. PrecisionOT.com
[email protected] Tel. 585-500-4090 6
PRE-SFP10G-LRM 10Gb/s SFP Transceiver, 1310 nm, 200m (LRM), DDM
Mechanical Dimensions
Precision Optical Transceivers, Inc. PrecisionOT.com
[email protected] Tel. 585-500-4090 7