Prewire for Models 103, 201, 203 Prewire for all “Pan”, “TES”, ‘’Vik”, “Elan”, etc.
Holovision Face Plate
Holovision Rough-in Box
From Main Equipment Area Essex CM-265 Controller
Cat 5/6 (communication) Cat 5/6 (camera)* 22/12* (cable for keypad) Other Low Voltage (See Note No. 1 below)
Note on Camera Cable : Use one Cat5 cable for Video if balun is used (Holovision P/N 9107)
To gate
Or use Coax + Low voltage Power.
Exit button (REX)
NOTE: Wires shown in red are the minimum required Wires shown in blue are optional
NOTE: Low voltage cable requirements include: 1. Telephone relay out - wires from phone system to gates (drive gate and pedestrian gate) 2. Release button (exit button) 3. 2 conductors 16/18 gauge for electric strike *Note on placement of Essex Controller: The Essex Model 265 controller is too large to fit in the Model 100 or Model 200 rough in box. It is recommended that the controller be placed in the equipment room. This 22 gauge 12 conductor cable (to conncect the keypad to the controller is recommended for a maximum of 250’. For longer distances, increase the wire gauge. Options: Model 401-S12 does not require this 12 conductor cable. See Model 401 Page 1
This document is property of Holovision, and may not be reproduced without permission
4 IC, Cam, 5XX
Prewire for Models 103, 201, 203 Prewire for VIO2 Holovision Face Plate
Holovision Rough-in Box
From Main Equipment Area
Cat 5/6 (communication)
Essex CM-265 Controller
VIO2
Cat 5/6 (camera) 22 gauge - 12 conductor for keypad*
Note on Camera Cable : Use one Cat5 cable for Video if balun is used (Holovision P/N 9107) Or use Coax + Low voltage Power.
To gate Exit button (REX)
NOTE: Wires shown in red are the minimum required Wires shown in blue are optional
Note: If VIO2 is used to activate the strike, the strike will relieve 12 VDC. If AC is required for the strike, a separate pair of wires should be supplied.
*Note on placement of Essex Controller: The Essex Model 265 controller is too large to fit in the Model 100 or Model 200 rough in box. It is recommended that the controller be placed in the equipment room. This 22 gauge 12 conductor cable (to connect the keypad to the controller) is recommended for a maximum of 250’. For longer distances, increase the wire gauge. 2 Cat 5 cables may be substituted for this 22/12 cable. Options: Model 400-S12 does not require this 12 conductor cable. See Model 400. Page 2
This document is property of Holovision, and may not be reproduced without permission
4 IC, Cam, 5XX
Door Station Rough-in
Model 103
Model 201, 203, 401, 411, 412
62”
58” NOTE: All dimensions given are relative to “finished” surface, not rough grade.
Page 3
This document is property of Holovision, and may not be reproduced without permission
4 IC, Cam, 5XX
Installation Details - 300 and 600 Series 1 3/4” reveal at top of box (beyond surface of finished masonry)
58” to top of box
Finished elevation
Installation on smooth wall
1 3/4” reveal at top of box (beyond surface of finished masonry)
58” to top of box
Finished elevation
Installation on stone wall
Page 4
This document is property of Holovision, and may not be reproduced without permission
4 IC, Cam, 5XX
Installation Details - 2 Piece Gooseneck
OPTION -conduit to gate. See second page for more details
Center of Rough-in template is 19” from edge of the curb (This will allow 1/2 of the intercom box to overhang) 48” to center
Gooseneck Rough-in Template
2” to top of rough-in template from surface of driveway
(this will place center of intercom box at 48”)
Ground level
Surface of finished driveway
Conduit to gate
Conduit to house
ROUGH-IN BRACKET INSTALLATION
Hand hole in pole Ground level
Conduit to gate (optional)
Use 3 or 4 bags of ready mix cement
Conduit to house
NOTE: PVC elbows must be facing in proper direction to minimize 900 bends in conduit to gooseneck
DETAIL OF ATTACHMENT OF POLE ONTO BASE
Page 5
This document is property of Holovision, and may not be reproduced without permission
4 IC, Cam, 5XX
Installation Details - 2 Piece Gooseneck Optional application with 2 conduits
2” Steel Gooseneck Pole
Cover for access door
NOTE: BE SURE THAT CONDUITS ARE SECURED BEFORE POURING CONCRETE. LARGE CONDUIT MUST BE PLUMB IN ORDER TO FIT INSIDE 2” GOOSENECK MOUNTING POLE
3/4” LB shown with male adapter, close nipple and lock nut (all of these parts are by others)
1 1/4”
sweep 90 deg elbow (by Holovision)
DO NOT GLUE MALE ADAPTER TO PVC PIPE!!
Ground level
1 1/4” 3/4” conduit to gate motor (elbow and conduit by others) Stainless Steel Mounting Bolts (4)
x
1”
reducer (by others)
1” (minimum) conduit to house
NOTE: BE SURE BOTH CONDUITS ARE POINTED IN THE DIRECTION THAT WILL MINIMIZE THE USE OF ELBOWS!
Page 6
This document is property of Holovision, and may not be reproduced without permission
4 IC, Cam, 5XX