Transcript
Price List 2013 Includes Specifications
January 2013
About Classeq Classeq Warewashing was a family business formed in 1977 to provide the hospitality industry with a range of robust, simple to use and cost effective range of glass and dishwashing equipment.
Working closely with our distributor partners from day one, we have enjoyed tremendous success having grown to dominate our sector in the market. In 2004 the company was purchased by Winterhalter. The majority of our products continue to be manufactured in the UK by a dedicated team in Staffordshire and remain competitively priced.
Classeq offers a complete range of glasswashers, undercounter and passthrough dishwashers as well as rack machines and utensil washers.
Classeq is supported by a nationwide network of directly employed service technicians. We also provide a complimentary range of chemicals, ancillary and accessory products, including water treatment and baskets.
In addition, Classeq is also the sole distributor of Ice-o-Matic ice machines, manufactured by Scotsman Industries Group and the Eau de Vie fresh filtered still and sparkling water system.
fresh filtered still & sparkling water systems
Classeq sells its products through a dedicated network of approved dealers throughout the UK and Ireland. We also have many partners throughout Europe. Classeq is proud to have its products in some of the countries leading foodservice outlets and is a member of CEDA, CESA, SRA and FCSI.
Classeq, Roebuck Way, Knowlhill, Milton Keynes, MK5 8WH Tel: 0844 225 9250, Fax: 0844 225 9251, Service Tel: 0844 225 9245 Email:
[email protected], www.classeq.co.uk
Contents Company Directory
Page 1
Installation Prices
Page 2
Eau de Vie
Page 4
Ice Machines
Page 8
Electrical Technical Data
Page 15
Water Treatment
Page 16
Glasswashers
Page 19
Front Loading Dishwashers
Page 23
Pass Through Dishwashers
Page 27
Rack Conveyor Dishwashers
Page 31
Utensil Washers
Page 41
Detergent and Hygiene Products
Page 43
Service and Maintenance Contracts
Page 44
Company Directory Direct Dial Main Line
0844 225 9250
Main Fax
0844 225 9251
Mobile
Email
[email protected]
Chief Executive
David B. Smithson
01908 359072
[email protected]
PA to Managing Director
Lisa Jacquest
01908 359072
[email protected]
Sales Director
Nick Burridge
01908 359094
07816 658242
[email protected]
Production Director
Gary Jones
01889 272301
07968 862001
[email protected]
General Manager
Nikki Meek
01889 272308
07805 792211
[email protected]
Commercial Manager
Brett Duffy
01908 359050
07767 791468
[email protected]
Area Sales Manager
Ed Johnstone
07767 791950
[email protected]
Area Sales Manager
Jim Jiwany
07816 658241
[email protected]
Main Sales Line - Tel: 0844 225 9249
Internal Sales Customer Service Manager
David Singer
01889 272324
[email protected]
Machine Order Entry
Mavis Payne
0844 225 9249
[email protected]
Machine Order Entry
Helen Punchard
0844 225 9249
[email protected]
Export Sales Co-ordinator
Eva Spiess
01889 272324
[email protected]
Ireland Sales Area Sales Manager
Sean Moore
00353 868 212 727
[email protected]
Marketing / Customer Care - Tel: 0844 225 9250 Sales & Marketing Executive
Anthony Matthews
01908 359024
[email protected]
John Goddard
0844 225 9245
[email protected]
Susan Sharratt
0844 225 9252
[email protected]
Service Department - Tel: 0844 225 9245 Service Account Manager
Spares Department - Tel: 0844 225 9252 Spares Control Administrator
Technical Support Technical Manager
Mick Hough
Technical Support Main Line
07979 531642
[email protected]
0844 225 0700
[email protected]
01889 272337 / 272303
[email protected]
Technical Support
Tyron Carter
Research & Development Technical Manager
Mark Downing
01889 272326
07976 724878
[email protected]
Finance Director
David Parsons
01908 359007
07979 531644
[email protected]
Financial Accountant
Tony Cantle
01908 359004
[email protected]
Credit Control Manager
Gina Pattinson
01908 359006
[email protected]
Purchase Ledger Controller
Pauline Hill
01908 359026
[email protected]
Finance Department
1
www.classeq.co.uk
Standard Installation Prices The Machine Connection Charge relates to a clear and accessible site with the correct electrical, water and waste services within one (1) metre uninterrupted of the machine and that the mains isolator and water valves are operable. Work carried out during normal working hours 9am - 5pm, Monday to Friday.
Category
Under Counter Glasswasher
Under Counter Dishwasher
Pass Rack Conveyor Through Dishwasher Dishwasher
Eco 1 Eco 2 Eco 3 Duo 2 Duo 3
Hydro 400 Hydro 700 Hydro 750 Hydro 800 Duo 400 Duo 750
Hydro 857 Hydro 957
ALTO 100 ALTO 130 ALTO 170 ALTO 170X ALTO 220 ALTO 280
Installation including £202 commissioning
£202
£300
Subject to site survey
£404
£202
£300
£325
£196
Commissioning only
£92 -
£92
£92
£92
£92
£92
£92
£92
£92
Removal of Existing machine
£95
£95
£158
Price on application
£158
£95
Rinse booster pump Fitted to plinth Wall mounted
£52 -
£117
£117
£117
-
-
Detergent dispenser
-
-
£56
£117
-
-
£61
£61
£61
-
-
-
-
£142
£142
-
-
Type
Manual Softener
Automatic Softener (2 hours plus parts, including D/check valve) Tabling and fabrication
Utensil Washer
Ice Machine
Ice Machine
Eau de Vie
VISO 50 ICEU35 to ICE0305 to Freestanding TT VISO 55 ICEU185 ICE1405 Remotehyjgyjk VISO 55H ICEU305, and GEM0655, VISO 70 ICEU225 MFI0805, VISO 132 and ICEF155 MFI1255
Tabling Fixing taps/ Wall mounted (sink/taps/ pre-shower to overshelf pre shower) existing sinks £192 £78 £78
NB: For Alto rack conveyor installations please contact Classeq for a free site survey and quotation.
January 2013
2
3
www.classeq.co.uk
fresh filtered still & sparkling water systems
January 2013
4
Eau de Vie water systems fresh filtered still & sparkling water systems
Eau de Vie systems supply 'real time' fresh filtered water from water delivered by the local mains supply. At the heart of every system are the unique Eau de Vie SilverSix Filters, part of a wider filtration system that removes those impurities which often adversely affect water composition and flavour. The filtered water is then chilled to the required temperature, optionally carbonated and delivered through a dispense tap (or taps) to provide a constant supply of premium-quality fresh filtered water, chilled still or sparkling. Eau de Vie systems were initially developed for the hospitality sector where high expectations for premium quality drinking water were matched by demanding logistical systems needs. The only on-site requirements for installation are one 13 amp 3-pin power socket within one metre of the location, and a cold mains water supply (minimum 3.5 bar pressure) within three metres of the location.
Optional extras and accessories. Accessories
5
www.classeq.co.uk
Description
Order Code
Price
Bottle Wash Rack
EDV-RACK
£52.00
Six-Bottle Carrier
EDV-CARRIER
£26.00
Rack Dolly
EDV-DOLLY
500ml Branded Bottle (box of 12)
EDV-500
£43.00
750ml Branded Bottle (box of 12)
EDV-750
£52.00
Branded Shrink-Wrap Seals (tub of 800)
EDV-SHRINK
'Still' Silver Bottle Top (box of 12)
EDV-CAP-S
£8.00
'Sparkling' Gold Bottle Top (box of 12)
EDV-CAP-G
£8.00
Branded Paper Cups (case of 560)
EDV-CUP
£139.00
Branded Paper Cup Dispenser
EDV-DISP
£165.00
Branded Aluminium Water Flask
EDV-FSK
Set of three filters (Free-standing & remote units)
EDV-FILTER
Single filter (TT units)
EDV-FILTER TT
£62.00
Sanitising Spay 750ml bottle (box of 6)
EDV-SAN
£26.00
Clear bottle collar 'Still' (box of 100)
EDV-COL.S
£52.00
Clear bottle collar 'Sparkling' (box of 100)
EDV-COL.SP
£52.00
£144.00
£155.00
£10.00 £155.00
Eau De Vie Branded Seal Still (1000)
£87.00
Eau De Vie Branded Seal Sparkling (1000)
£87.00
EDV - TT
EDV - MF & LF EDV - MR & LR
Table Top Units This compact dispense unit is an ideal solution where space is at a premium. Connected directly to the mains water supply, water is filtered and chilled but can still be served in still or sparkling variants.
Free-standing units These self contained, wheeled units come in two different sizes and single dispense taps or dual-headed taps. Filters and cooling chambers are hidden inside but remain easily accessible from the door on the front.
Remote cassette units The slot-in cassette version, available in two sizes, is operationally identical to its free-standing unit equivalent. It can however be installed on existing shelving and sited remotely from the dispense tap or taps, affording more flexibility in confined spaces.
Specifications - EDV-TT
Specifications - EDV-MF
Specifications - EDV-MR
Width ____________________________________ 408 mm Depth (Excluding Drip Tray) ________________ 533 mm Depth (Including Drip Tray) _________________ 626 mm Height (Main Unit) ________________________ 510 mm Height (Including Taps)_____________________ 540 mm Cold water mains potable supply ______ ¾ BSP Isolator Water Pressure _______________ Min 1.5 / Max 3.5 Bar Excess spillage into drip tray __ (No drainage required) Mains Supply ______________________ 230 V 1Ph 50 Hz Run Current______________________________ 5.1 Amps Start Current ____________________________ 10.7 Amps Fuse at __________________________________ 10 Amps Supply Lead __________ 2M Mains Cable 3 Pin UK Plug
Width ___________________________________ 1000 mm Depth ____________________________________ 750 mm Height (Including wheels and tap) _________ 1485 mm Height (Excluding tap) _____________________ 905 mm Cold water mains potable supply ______ ¾ BSP Isolator ___________________________________(3/4 BSP - 3/8 Adaptor required) Water Pressure _______________ Min 1.5 / Max 3.5 Bar Excess spillage into drip tray __ (No drainage required) Mains Supply ______________________ 230 V 1Ph 50 Hz _______________________________________(Rated input 800 Watts) Run Current_____________________________ 3.47 Amps Start Current _____________________________ 7.0 Amps Fuse at __________________________________ 10 Amps Supply Lead __________ 2M Mains Cable 3 Pin UK Plug
Width ____________________________________ 500 mm Depth ____________________________________ 600 mm Height (Including wheels and tap)___________ 720 mm Cold water mains potable supply ______ ¾ BSP Isolator ___________________________________(3/4 BSP - 3/8 Adaptor required) Water Pressure _______________ Min 1.5 / Max 3.5 Bar Excess spillage into drip tray __ (No drainage required) Mains Supply ______________________ 230 V 1Ph 50 Hz _______________________________________(Rated input 800 Watts) Run Current_____________________________ 3.47 Amps Start Current _____________________________ 7.0 Amps Fuse at __________________________________ 10 Amps Supply Lead __________ 2M Mains Cable 3 Pin UK Plug
Specifications - EDV-LF
Specifications - EDV-LR
Width ___________________________________ 1000 mm Depth ____________________________________ 750 mm Height (Including wheels and tap) _________ 1485 mm Height (Excluding tap) _____________________ 905 mm Cold water mains potable supply ______ ¾ BSP Isolator ___________________________________(3/4 BSP - 3/8 Adaptor required) Water Pressure _______________ Min 1.5 / Max 3.5 Bar Excess spillage into drip tray __ (No drainage required) Mains Supply ______________________ 230 V 1Ph 50 Hz _______________________________________(Rated input 800 Watts) Run Current_____________________________ 3.47 Amps Start Current _____________________________ 7.0 Amps Fuse at __________________________________ 10 Amps Supply Lead __________ 2M Mains Cable 3 Pin UK Plug
Width ____________________________________ 800 mm Depth ____________________________________ 600 mm Height (Including wheels and tap)___________ 720 mm Cold water mains potable supply ______ ¾ BSP Isolator ___________________________________(3/4 BSP - 3/8 Adaptor required) Water Pressure _______________ Min 1.5 / Max 3.5 Bar Excess spillage into drip tray __ (No drainage required) Mains Supply ______________________ 230 V 1Ph 50 Hz _______________________________________(Rated input 800 Watts) Run Current_____________________________ 3.47 Amps Start Current _____________________________ 7.0 Amps Fuse at __________________________________ 10 Amps Supply Lead __________ 2M Mains Cable 3 Pin UK Plug
Free Standing Units - Capacity
Remote Cassette Units - Capacity
Table Top Unit - Capacity Model 408 533
Table Top 510 Unit
Product code EDV-TT
Water production litres per hour
Continuous bottle production 33
25
Price
£3050
Model
Product code 600
Medium Free-standing Unit
72
70
905
Price
600
600
905
Large Free-standing Unit
Continuous bottle production
Model 600
EDV-MF 905
Water production litres per hour
1485
Medium Remote Unit
108
Price
EDV-MR
70
72
Price
905
100
Continuous bottle production
720
600
EDV-LF
Water production litres per hour
£7355
1485
600
Product code 500
£7880
Large Remote Unit
720
£6730
800
EDV-LR
100
108
Price
£7255
These units are also available for rental over 3 or 5 years. Please speak to your Sales Representative for details.
January 2013
6
7
www.classeq.co.uk
January 2013
8
Ice Machines
Ice-O-Matic is part of the Scotsman Industries Group. Manufactured from highly polished food safe stainless steel and fully insulated throughout. Using spray technology to produce long lasting crystal clear ice in individual thimble shaped cubes (ICEU35 to ICEU185 models). Front venting air intake and exhaust allow installation in the tightest areas. The larger selfcontained models and modular machines have the option of full cube or half cube shaped ice. Removal of key parts for maintaining hygiene standards is simple and tool free providing quick and easy cleaning. Generous bin design allows for easy, ergonomic access to the ice for the operator. AgION antibacterial compound is used to reduce harmful bacteria growth and maintain food safety between cleaning cycles.
Optional extras and accessories.
9
Accessories
Description
Order Code
Drain Pump - External
All models
99-05-860
£210.00
Plinth - 600mm high
ICEU 35 ICEU 45 ICEU 65 ICEU 85 ICEU 105 ICEU 145/185
ICE-SS35 ICE-SS45 ICE-SS65 ICE-SS85 ICE-SS105 ICE-SS145/185
£185.00 £185.00 £185.00 £185.00 £185.00 £185.00
Filter
ICEU 35 to ICEU 145, ICEF155 ICEU 185 to ICEU 305
ICE-FILT1 ICE-FILT2
£42.00 £219.00
ICEO 305 to ICE1405, GEMO655
ICE-FILT3
£375.00
Replacement Cartridge
ICEU 35 to ICEU 145, ICEF 155 ICEU 185 to ICEU 305 ICEO 305 to ICE1405, GEMO655
ICE-CART1 ICE-CART2 ICE-CART3
£89.00 £102.00 £219.00
Ice Machine Descaler & Sanitiser
All models 6 x 500ml bottles of cleaner and 2 x 750ml spray sanitiser
IMDS1
www.classeq.co.uk
Price
£99.00
Cube Ice Makers with Built-in Storage Bin
Specifications CEU ICEU CEU U ICEU ICEU ICEU Cube Cube Cube Cube Cube Cube Cube Ice Ice Ice Ice Makers Ice Ice Ice Makers Makers Makers Makers Makers Makers with with with with with with Built-In with Built-In Built-In Built-In Built-In Built-In Built-In Storage Storage Storage Storage Storage Storage Storage BinBin Bin Bin Bin Bin Bin ICEU CEU ICEU ICEU ICEU Cube Cube Cube Cube Cube Ice Ice Ice Ice Ice Makers Makers Makers Makers Makers with with with with with Built-In Built-In Built-In Built-In Built-In Storage Storage Storage Storage Storage Bin Bin Bin Bin Bin CEU Cube Ice Makers with Built-In Storage Bin
Approx. Approx. Approx. Approx. Approx. Approx. Approx. Single BinBin Bin Bin Bin Bin Bin Shipping Shipping Shipping Shipping Shipping Shipping Shipping phase Electrical Storage Storage Storage Storage Storage Storage Storage ListList List Price List List List Price List Price Price Price Price Price Condensing Condensing Condensing Condensing Condensing Condensing Condensing Weight Weight Weight Weight Weight Weight Weight Supply Approx. Approx. Approx. Approx. Approx. Ice Ice Production Ice Ice Ice Ice Production Ice Production Production Production Production Production Ice Ice Production Ice Ice Ice Ice Production Ice Production Production Production Production Production Cube Approx. Kgs Kgs Kgs Kgs Kgs Kgs Bin Bin Bin Bin Bin °C °C °C °C °C °C °C Kg/24 (£) (£) (£) (£) (£) Unit Unit Unit Unit Unit Unit Unit Kgs Kgs Kgs Kgs Kgs Kgs Kgs Shipping Shipping Shipping Shipping Shipping @ @ @ @@ @ @ Kg/24 Kg/24 Kg/24 Kg/24 Kg/24 hr Kg/24 Kg/24 hr hr hr hr hr hr @ 32 @ @ °C @ 32 @ 32 @ 32 @ °C 32 32 °C 32 °C °C °C °CKgsBin Kg/24 Kg/24 Kg/24 Kg/24 hr Kg/24 Kg/24 hr hr hr hr hr hr 21 21 21 21 21 21 21 dimensions dimensions dimensions dimensions dimensions dimensions in mm ininin mm inmm inmm inmm mm mm(£) (£) All dimensions All All All All All All Size Amps Shipping Storage Storage Storage Storage StorageCondensing List List List List List Price Price Price Price Price Condensing Condensing Condensing Condensing Condensing Weight Weight Weight Weight Weight Weight Ice Ice Ice Ice Ice Production Production Production Production ProductionIce Ice Ice Ice Ice Ice Production Production Production Production Production Storage List Price Ice Production Production Kgs Kgs Kgs Kgs Kgs °C °C °C °C °CKg/24 (£) (£) (£) (£) (£) Kg/24 Unit Unit Unit Unit Unit Kgs Kgs Kgs Kgs Kgs @ @@ @ @ Kg/24 Kg/24 Kg/24 Kg/24 Kg/24 hr hr hr @ @@ 32 @ 32 @ 32 32 °C 32 °C °C °C °C Kgs Kg/24 Kg/24 Kg/24 Kg/24 Kg/24 hr hr hr 21 21 21 21 21 dimensions dimensions dimensions dimensions dimensions inininmm inmm inmm mm mm (£) All All All All All °C Unit Kgs @hr hrhr @hr 32 °C hrhr 21 Medium £925 19 17 6.5 Air 32 ICEU35 All dimensions in mm 13 20g 597 ICEU35P £1185 (with integral drain pump)
457
334
ICEU45
23 23 23 23 23 £890 £890 £890 £890 £890 £890 £890 Medium23 23 £970 20g 23 23 23 23 £890 £890 £890 £890 £890 £1230 2323 £890
20 20 20 20 20 20 20
8 888888
Air Air Air Air Air Air Air
36 36 36 36 36 36 36
20 20 20 20 2020
8 88888
Air Air Air Air Air Air
36 36 36 36 3636
£975 £975 £975 £975 £975 £975 £975 £1060 Medium28 28 28 28 28 28 28 20g £975 £975 £975 £975 £975 28 28 28 28 £1360 £975 2828
26 26 26 26 26 26 26
15 15 15 15 15 15 15
Air Air Air Air Air Air Air
44 44 44 44 44 44 44
26 26 26 26 2626
15 15 15 15 1515
Air Air Air Air Air Air
44 44 44 44 4444
38 38 38 38 38 38
36 36 36 36 36 36 36
16 16 16 16 16 16 16
Air Air Air Air Air Air Air
48 48 48 48 48 48 48
38 38 38 38 3838
36 36 36 36 3636
16 16 16 16 1616
Air Air Air Air Air Air
48 48 48 48 4848
46 46 46 46 46 46 46
18 18 18 18 18 18 18
Air Air Air Air Air Air Air
54 54 54 54 54 54 54
46 46 46 46 4646
18 18 18 18 1818
Air Air Air Air Air Air
54 54 54 54 5454
65 65 65 65 65 65 65
30 30 30 30 30 30 30
Air Air Air Air Air Air Air
66 66 66 66 66 66 66
65 65 65 65 6565
30 30 30 30 3030
Air Air Air Air Air Air
66 66 66 66 6666
Medium86 86 £2240 £2065 £2065 £2065 £2065 £2065 £2065 £2065 86 86 86 86 86 20g £2585 £2065 £2065 £2065 £2065 £2065 86 86 86 86 £2065 8686
77 77 77 77 77 77 77
30 30 30 30 30 30 30
Air Air Air Air Air Air Air
78 78 78 78 78 78 78
77 77 77 77 7777
30 30 30 30 3030
Air Air Air Air Air Air
78 78 78 78 7878
706 £2870 £2650 £2650 £2650 £2650 £2650 £2650 £2650 96 96 96 96 96 Full Cube96 96 ICEU225F 991 991 991 991 991 991 991 £2870 ICEU225 ICEU225 ICEU225 ICEU225 ICEU225 ICEU225 ICEU225 ICEU225H £2650 £2650 £2650 £2650 £2650 Half Cube 9696 96 96 96 96 £2650 991 991 991 991 991 991 ICEU225FPorHP £3215 ICEU225 ICEU225 ICEU225 ICEU225 ICEU225 610 610 610 610 610 610 610 610 610 610 610 610 610 610 ICEU225
65 65 65 65 65 65 65
34 34 34 34 34 34 34
Air Air Air Air Air Air Air
73 73 73 73 73 73 73
13
65 65 65 65 6565
34 34 34 34 3434
Air Air Air Air Air Air
73 73 73 73 7373
13
90 90 90 90 90 90 90
51 51 51 51 51 51 51
Air Air Air Air Air Air Air
94 94 94 94 94 94 94
13
90 90 90 90 9090
51 51 51 51 5151
Air Air Air Air Air Air
94 94 94 94 9494
13
70 70 70 70 70 70 70
71 71 71 71 71 71 71
25 25 25 25 25 25 25
Air Air Air Air Air Air Air
59 59 59 59 59 59 59
70 70 70 70 70 7070
71 71 71 71 71 7171
25 25 25 25 25 2525
Air Air Air Air Air Air Air
59 59 59 59 59 5959
ICEU45 ICEU45 ICEU45 ICEU45 ICEU45 ICEU45 ICEU45 ICEU45P
640 640 640 640 640 640 640
(with integral drain pump)
ICEU45 ICEU45 ICEU45 ICEU45 ICEU45 ICEU45
13
640 640 640 640 640 640
517 517 517 517 517 517 517 393 393 393 393 393 393 393
ICEU65 ICEU65P
517 517 517 517 517 393 393 393 393 393 517 393 690 690 690 690 690 690 690
ICEU65 ICEU65 ICEU65 ICEU65 ICEU65 ICEU65 ICEU65 (with integral drain pump)
ICEU65 ICEU65 ICEU65 ICEU65 ICEU65 ICEU65
13
690 690 690 690 690 690
587 587 587 587 587 587 587 469 469 469 469 469 469 469 587 587 587 587 587 469 469 469 469 469 587 469 £1370 Medium38 £1260 £1260 £1260 £1260 £1260 £1260 £1260 815/940 815/940 815/940 815/940 815/940 815/940 815/940 20g
ICEU85 ICEU85 ICEU85 ICEU85 ICEU85 ICEU85 ICEU85 ICEU85 ICEU85P
£1675 £1260 £1260 £1260 £1260 £1260 £1260
(with integral drain pump) 815/940 815/940 815/940 815/940 815/940 815/940 ICEU85 ICEU85 ICEU85 ICEU85 ICEU85 528 528 528 528 528 528 528 ICEU85 535 535 535 535 535 535 535
528 528 528 528 535 535 535 535 535 Medium50 50 £1675 ICEU105 528528 50 50 50 50 50 £1540 £1540 £1540 £1540 £1540 £1540 £1540 535 796/921 796/921 796/921 796/921 796/921 796/921 796/921 20g ICEU105P £2020 50 50 50 50 50 £1540 £1540 £1540 £1540 £1540
13
13
ICEU105 ICEU105 ICEU105 ICEU105 ICEU105 ICEU105 ICEU105 (with integral drain pump)
796/921 796/921 796/921 796/921 796/921 ICEU105 ICEU105 ICEU105 ICEU105 ICEU105 796/921 538 538 538 538 538 538 538 ICEU105 535 535 535 535 535 535 535
£1540
50
538 538 538 538 535 535 535 535 535 Medium70 70 ICEU145 538538 £1955 £1800 £1800 £1800 £1800 £1800 £1800 £1800 70 70 70 70 70 535 885/1010 885/1010 885/1010 885/1010 885/1010 885/1010 885/1010 20g ICEU145P £2295 £1800 £1800 £1800 £1800 £1800 70 70 70 70 70
ICEU145 ICEU145 ICEU145 ICEU145 ICEU145 ICEU145 ICEU145
£1800
(with integral drain pump) 885/1010 885/1010 885/1010 885/1010 885/1010 ICEU145 ICEU145 ICEU145 ICEU145 ICEU145 534 534 534 534 534 534 534 885/1010 ICEU145 706 706 706 706 706 706 706
534 534 534 534 534 706 706 706 706 706 706
ICEU185 534 ICEU185 ICEU185 ICEU185 ICEU185 ICEU185 ICEU185 ICEU185 ICEU185P
70
13
13
885/1010 885/1010 885/1010 885/1010 885/1010 885/1010 885/1010
(with integral drain pump) ICEU185 ICEU185 ICEU185 ICEU185 ICEU185 885/1010 885/1010 885/1010 885/1010 885/1010 534 534 534 534 534 534 534 ICEU185 885/1010 706 706 706 706 706 706 706
534 534 534 534 534 534 706 706 706 706 706
(with integral drain pump)
ICEU305F ICEU305 ICEU305 ICEU305 ICEU305 ICEU305 ICEU305 ICEU305 ICEU305H
610 610 610 610 610610 610 610 610 610 610 610 991 991 991 991 991 991 991
ICEU305 ICEU305 ICEU305 ICEU305 ICEU305 ICEU305FPorHP ICEU305 737 737 737 737 737 737 737 (with integral drain pump)
991 991 991 991 991 991 762 762 762 762 762 762 762
Full Cube £3685 £3400 £3400 £3400 £3400 £3400 £3400 £3400 118118 118 118 118 118 118 £3685 Half Cube 118 £3400 £3400 £3400 £3400 £3400 118 118 118 118 118 £3400 £4025
737 737 737 737 737 737 762 762 762 762 762 762
£3350 £3350 £3350 £3350 £3350 £3350 Self Contained £3350 Flaker ICEF155 ICEF155 ICEF155 ICEF155 ICEF155 ICEF155 ICEF155
ICEF155 ICEF155 ICEF155 ICEF155 ICEF155 ICEF155 ICEF155
796/921 796/921 796/921 796/921 796/921 796/921 796/921
£3350 £3350 £3350 £3350 £3350 £3630 £3350
13
796/921 796/921 796/921 796/921 796/921 796/921 538 538 538 538 538 538 538 £3970 535 535 535 535 535 535 535 Self Self Self contained Self Self Self Self contained contained contained contained contained contained flaker flaker flaker flaker flaker flaker flaker
ICEF155P
(with integral drain pump)
538 538 538 538 538 538 535 535 535 535 535 535
Self Self Self Self Self contained contained contained contained contained flaker flaker flaker flaker flaker Self contained flaker
Approx. Approx. Approx. Approx. Approx. Approx. Approx. Shipping Shipping Shipping Shipping Shipping Shipping Shipping List Price Condensing Weight ListList List Price List List List Price Price Price Price Price Condensing Condensing Condensing Condensing Condensing Condensing Weight Weight Weight Weight Weight Weight Approx. Approx. Approx. Approx. Approx. Ice Production Ice Ice Production Ice Ice Ice Ice Production Production Production Production Production Ice Production Ice Ice Production Ice Ice Ice Ice Production Production Production Production Production Approx. °C Kg/24 °C °C °C °C °C °C (£) (£) (£) (£) (£) (£) (£) Unit Shipping Kgs Unit Unit Unit Unit Unit Unit Kgs Kgs Kgs Kgs Kgs Kgs Shipping Shipping Shipping Shipping Shipping @ @ @ @ @@ @ Kg/24 hr Kg/24 Kg/24 Kg/24 Kg/24 Kg/24 hr Kg/24 hr hr hr hr hr @ 32 °C @ 32 @ @ °C @ 32 @ 32 @ 32 °C 32 32 °C °C °C °C Kg/24 hr Kg/24 Kg/24 Kg/24 Kg/24 hr Kg/24 hr hr hr hr hr 21 21 21 21 21 21 21
Please see page 12 for important water supply information
January 2013
10
TIC04-09:ICE ICE OMATIC04-09:ICE OMATIC 20-10-2009 OMATIC 20-10-2009 12:19 Pagina 12:19 2
Pagina 2
TIC04-09:ICE ICE OMATIC04-09:ICE OMATIC 20-10-2009 OMATIC 20-10-2009 12:19 Pagina 12:19 2
Pagina 2
Ice Machines
ICEU Cube Ice Makers with Built-In Storage Bin All dimensions in mm
List Price (£)
Ice Production Kg/24 hr @ 21°C
Ice Production 22mm Kg/24 hr @ 32 °C
991
508 508
762
Unit
ICEU225FA
ICE0305FW ™ Specifications ICE0305FA ICEU Cube Ice Makers with Ice Built-In Storage BinICEU225 ICE Series ICE Cube Series Ice™ Cube Makers Makers ICE0305FA ICE0305FW ICEU225 ICE0305FW ™ ICEU225 ICE Series ICE Cube Series Ice™ Cube Makers Ice Makers ICE0305FA
ICEU225FW ICEU225FA ICEU225FA ICEU225FW ICEU225FW ICEU225FA
991 991
17.3” (440 mm)
Approx. Approx. Approx. Single 610 610 508 762 phaseH Bin Shipping Shipping Shipping 991 610 762 23 20 Air £890 ICE0305FW 8 ICEU225FW Electrical Approx. Approx. 610 ICEU225 ICEU Cube Ice Makers with Built-In Storage Bin H ICE0305FA ICEU225FA Storage 610 ListPrice Price Condensing Weight List ListProduction Price Condensing Condensing Weight Weight Ice Production Ice Ice Production Ice610 Production Ice Production Ice Production 508 991 610 H Supply 610 Shipping Shipping 640 Approx. ICE0305FW ICE0305FA ICEU225FW ICEU45 ICEU225FA 762 Kgs °C °C °C (£) Unit Kgs (£) (£) Unit Unit Kgs Kgs 508 @ Kg/24 hr @ @ Cube Size Kg/24 hr Kg/24 hr @ 32 °C Kg/24 hr @ 32 °C @ 32 °C Kg/24 hr Kg/24 hr 21 21 21 dimensions in mm All ICEU225 610 Amps All dimensions in Allmm dimensions in ICE0305FW mm 991 List Price ListProduction Price Condensing Bin Condensing Weight WeightShipping Ice Ice 610Production Ice Production ICEU225FW H ICEU225 Ice Production 610 762 StorageUnit Condensing Weight List Price Ice Production Ice Production 610 D °C °C@ 32 (£) (£) Unit Kgs Kgs @ @ Kg/24 hr Kg/24 hr °C @ 32 °C Kg/24 hr Kg/24 hr 21 21 ICE0305FA ICEU225FA ICEU305FA 508 All dimensions in Allmm dimensions in mm 584 762 Kgs 991 (£) Unit Kgs @ 21°C Kg/24 hr 610 H @ 32 °C hr Kg/24 All dimensions in mm ICE0325FA 610 W 610 991 ICE0305FW ICEU225FW ICEU305FW 97 Air ICE0305F Cube £3505517 Full £3250 £3250 137 137 610 97 68 Air 68 ICEU225 13 H D 393 ICEU305 ICEU305FA 508 508 610 610
ICE0305
ICE0305H ICE0305
ICE0305
610 ICE0305 610
ICE0325 ICE0325
ICE0325F ICE0325H ICEU45 ICE0325 ICE0325 610
762 559
610 610
508
610 610 762 610
610 762
508 610 610
610
ICE0405 ICE0405
ICE0405 610 610
ICE0525
ICE0525F ICE0525 ICE0525H
ICE0525 ICE
ICEICEU85 0525 ICE 610
610 610 559
ICE
610
ICE0605
ICE0605F ICE0605 ICE0605H
ICE0605
ICEU105 ICE0605 610
ICE0805 ICE0805
ICE0805F ICE0805 ICE0805H
ICEU145 ICE0805 610 610
ICE1005
ICE1005F ICEU185 ICE1005 ICE1005H
ICE1005
ICE1005 610 610
ICE1405
ICE1405F ICEU225 ICE1405 ICE1405H
ICE1405
ICE1405 610
ICEU305
ICE0325FA
584
584
584
£3685 £3400
640 ICE0405FW ICEU45 ICE0405FA 584
GEM0655 GEM0655
ICEU305 815/940
559
ICE0405FW ICEU85 517 ICE0405FA
559762 393 610 762
508
393
ICE0405FW ICE0405FA
559
£3900
£3600 528 ICE0405FW ICE0405FA 508 508 £975 ICEU65ICE0405FW £3900 £3600 762 690 ICE0525FA 508584 508 ICE0405FA
762 610
584 584
610 762 610 610 587 610 610 610
559 559762
610 610 559
469
584
559
584
610559
GEM0655
Full Cube GEM0655 235 £3600 £975 28 GEM0655 690 Half Cube 235 £3600 535
GEM0655
508
762
559 762
Full£3400 Cube 137ICEU305 23 469 £890 GEM0655 Half Cube 137 £3400 ICEU305 640
ICE0325FA ICE0405FA ICE0405FW
508 508
762 ICE0405FW ICE0525FA 587 ICE0525FA ICE0405FA 508
ICEU105
796/921 MFI0805
469
762ICE0405FW ICE0525FA
584
£3 600 £3900 538
584 ICEU85 ICE0525FA 584
ICE0525FA £3900 £1260 £3 600 584 584 815/940 ICE0605FA 528
535
MFI0805
Half 38 £3Cube 00 6254
MFI0805
535
991
762 610 762
737 737610
737
762
23
737 737
762
137
137 762
991
686 991686
£1260 762 737 610
533 762
737 610 610
235 28
610
235 610 £1540 610
686
533 533
168686 26686 533 168
610
533
610 610
533 533
610254 610 £1800
762
ICE0605FW 508 ICE0805FW 660 762 ICE0805FA
£1540 796/921
MFI0805
283 Full Cube 706£4400
MFI1255 MFI0805 50 MFI1255 £4400 283 Half Cube MFI1255
£1800 885/1010
MFI1255
885/1010
MFI1255 408 MFI1255 £5500 706 Full Cube
610
50
610
D
68 Air 8
ICEU305FA GEM0655 ICEU305FW 38 GEM0655 GEM0655
GEM0655 GEM0655
26168Air
36 686 184 533 533
75 Air 46
610 610
70
610 610
762 762
660508 660
16
16 MFI0805AS184Air 70 MFI0805AS
686
46 MFI0805AS
610
36
68 W W
D Air 610 610 610
W
75 W W
75 W 18
75
46 212 533
686 686
MFI1255AS212Air MFI0805AS MFI1255AS 18 MFI1255AS212Air
533 533
686
MFI1255AS 65
533 533
686
MFI1255AS
80 Air 80 Air Air 77
86
30
H
44 H
44
H
W
48 864
75 610
48
30 CRT125 610
610
610 CRT125
610
CRT125 80 610 30 CRT125
864 864
100 Air
13 13 Air
864
80
864
54
13 ICEU35
ICEU35 13 ICEU35 Air
66
ICEU35 ICEU35 ICEU35 16
100 6678 34
ICEU35 16 Air
610
100 CRT125
Air Air Air 30 100 65
Air
54
CRT125
MFI1255AS
13
610
610
Air
13
864 864 864
610
610
Air
W
ICEU35 105 Air
34
Air Air
105 Air 90
105
7873
105 51
51
Air
141 AirAir
73
141 25
25
Air
94
141
141 Air 71
16 16
Air
32 32
1219
ICE1405FR ICE1405FA 538
991
610 1219
660
ICE1405FW ICE1405FA ICE1405FR
660
ICE1405FW
610
762
1219
535
851
762
Air
59
Air
851
762
94
Self contained flaker
ICE1405FR
610
Approx. Shipping
1219 610
ICEF155 796/921
£3350 70Production 71 25 Weight Air List PriceList Ice Condensing Price Condensing Ice Production Ice Production Ice Production °C (£) Kg/24 hr @ 21 Kg/24 °C@ 32 °CKg/24Unit (£) @ 21hr Kg/24 hr hr @ 32 °C Kgs Unit £6100 £6605 £6100 Self contained £6220 flaker £6375
GEM0655 (Nugget)* 538 535 MFI0805 (Flaker)* MFI1255 (Flaker)*
Ice
318 343
Approx. Single Shipping phase Weight 59 Electrical Supply Kgs Amps
236 236
Air
93
16
259
Air
93
16
506 375 Air 93 Ice £7805 16 * These ice makers require bin adaptor KBT 19 to fit a 762mm wide bin. Ice storage bins sold seperately
610
Approx.
610
List Price
11 www.classeq.co.uk(£)
236
Please see page 12 for important water supply information Shipping Ice Production Kg/24 hr @ 21°C
Ice Production Kg/24 hr @ 32 °C
Condensing Unit
Weight Kgs
(457 mm) (610 justable 17.3”mm) “ (305 mm) (440 mm) justable (457 mm) “ (305 mm) (610 17.3”mm) (457 mm) (610 mm) mm) (440 justable 17.3” “ (305 mm) mm) (440 (457 mm) (610 mm) justable “ (305 mm) 17.3”mm) (457 justable mm) (440 mm) (305 mm) “ (610 (457 mm) (610 mm)
17.3” justable mm) (440
3
3 3
3
3
3
3
3
13
H
W
610 Air CRT125 CRT125
18
W
13
H
16
D
H H
17.3” mm) (440 17.3” justable (440 mm) “ (305 mm)
“ (305 mm) (457 mm) (610 mm) justable “ (305 mm) (457 mm) (610 mm)
1351
610
Specifications 737
36
D D
D
75 Air Air 65
W
68
610
533
Air
W
D
D Air
Air
75 Air
Pearl and Flaked Ice Modular Ice Makers ICEU305
H
H
D
ICE0605FA 534 ICE0605FR 534 ICE0805FR ICE0805FA 408 280 686 280Air £5500 £5960 706 ICE0805FW ICE0605FW ICE0805FW 610 533 660 ICE0805FR ICE0805FA ICE0605FR £1800 70 65 686 MFI1255AS280Air 30 ICE0805FR 408 408 280 £5500 £5500 £5960 Half Cube £2065 MFI1255 86 77 610 533 ICE0805FW 96 660 885/1010 660 660 1351 762 ICE0805FA 762 ICEU185 CD40522 £2650 885/1010 610 610 610 533 686 MFI1255AS ICE0805FR 762 991 610 762 762ICE0805FW ICE0805FA MFI1255 660 ICEU225 1351 610 CD40522 ICE0805FR 1351 534 ICE0805FW CD40522 534 660 762 610 533 706 706 610 851 762 762ICE0805FA 559 ICE0805FR 610 ICE1005FA 610 610 1351 762 610 ICE0805FW 467 CD40522 610 467 337 337Air 851 £6400 £6400 Full Cube £6940 660 533 ICE1005FW 660 559 £2650 65 ICE1005FA 762 851 96 ICE0805FA 610 86 77 30 559 ICE0805FR£2065 1351 CD40522 ICE1005FR ICE1005FA 991 660 660 660 ICE1005FW ICEU225 ICE0805FW 467 CD40522 467 337 337Air £6940 £6400 £6400 Half Cube 885/1010 660 1351 660 ICE1005FW 851 £3400 118 762 ICE1005FR 559 762 ICE0805FR ICE1005FA 610 610 ICE1005FR 660 660 610 851 660ICEU305 ICE1005FW 610 991CD40530 762 559 1351 CD40522 ICE1005FA 534 610 762 762 851 610 706 ICE1005FR 762 1351 610762 610 559 660 ICE1005FW CD40530 ICE1005FA CD40530 CD40522 £3400 118 1351 90 660 762 ICE1005FR ICE1005FW 1351 737 610762 762 851 762 610 1351 559 ICEU305 ICE1005FR ICE1005FA 851 £2650 991Full 96CD40530 65 34 ICE1405FA 762 762 £7200 £7200 574 410 574 410Air Cube £7800 610 660991660 ICE1005FW ICE1405FW 851 1351 762 851 ICE1405FA660 559 762 CD40530 610 ICE1005FA 660 737 ICE1005FR ICE1405FR 851 ICE1405FA £7200 £7200 574CD40530 £3350 410 574 410Air 762 £7800 Half Cube 762 660 ICE1405FW 70 660 1351 ICE1005FW 660 ICE1405FW ICEF155 762 1219 ICE1405FR660 660 1351 851 ICE1005FR 610 ICE1405FA 610 610 610 762 ICE1405FR 796/921 CD40530 £3350 660 ICE1405FW 1219 1219 70 71 1219 762 851 ICE1405FA 610 610 762 1219 ICEF155 610 ICE1405FR 1351 610 851 660 ICE1405FW 796/921 ICE1405FA 762 CD40530 1219 1219 £3400 118 90 51 538 610 1219 ICE1405FR 660 ICE1405FW 535 Self contained flaker 660
610 610
75 Air
MFI0805AS
686
212 686 533 686
283 610 £2065
Air D
533
283
610
D
68 Air
15
15 168Air
184Air
686
Air
36
50
184
13
H
MFI0805AS GEM0655 686 686 MFI0805AS 686 MFI0805AS GEM0655 36
533
38 254
ICEU305FW ICEU305FA
GEM0655
W W
68 15
W D
97 Air 8 20 ICEU305FW 97 Air
686
D
ICEU305FW ICEU305FA
ICEU305FA
686
533
D
68 Air 26
ICEU305FW
97 20 991686 97
MFI0805 885/1010
ICE0605FR ICE0605FA 508 ICE0605FW 528 559 610 559 ICE0605FW 584 508 ICE0525FA 535762 ICEU105 ICE0605FR 534 610 ICE0605FA 559 £4400 £4765 610 ICE0605FR 508 508 ICE0605FW 762 508 610 ICE0605FA 538 535 559762 £1540 £4400 ICE0605FR 610 £4765 610 508 ICE0605FW 508796/921ICE0605FA508 762 ICE0605FW 508 ICE0605FR 610 762 762 ICEU185 610 ICE0605FR ICE0605FA ICE0805FA ICEU145 538 762 610535 762 610
GEM0655 MFI0805 MFI0805 £1260 Cube
Full £36254 00
815/940
ICE0605FW 559 508 ICE0525FA 584 ICEU145 ICE0605FA
559
991 991
991 137 97 610 £975 762
737 610
ICEU305
587 584 £890 ICE0405FA ICE0325FA
508
ICEU225FA ICEU305FA ICEU305FW ICEU225FW ICEU305FW 97 Air 28 ICEU305FA
991
762 ICE0325FA
508
610
690
£3685 £3400
559 762
610
ICEU305
ICE0325FA
584
610
610
ICEU305 Half Cube £3250 137 ICEU225
ICEU65
762508
610
610
559
ICE0305FA ICE0325FA ICE0325FA ICE0305FW £3505 £3250
762
584 559
610
610
ICE
584
559
610
610 610 559 610
559 762 559
584
517
ICE0405F ICE0405 ICE0405H ICEU65
584 508 584
A Sh W
22mm
10mm
ICE0305FA
508
22mm Condensing
22mm
22mm
Cube Ice Makers
Bin Storage Kgs
Storage Storage Bins Bins Storage Bins Specifications Model Number
Application Bin List PriceModel List Price Storage (£) Number Kg (£)
Bin ARI Dimensions Bin WxDxH Storage mm Kgs
Approx. Bin Shipping Dimensions Weight WxDxH Kgs mm
Approx. Shipping Weight Kgs
B25
£875 116£955
86116
86 762x787x711
41 762x787x711
41
B40
£1159 B40
166£1265 £1159
123 166
123 762x787x953
61 762x787x953
61
B42
£1160 B42
170£1265 £1160
125 170
559x787x1270 125
559x787x1270 61
61
B55
£1300 B55
£1300 253£1415
182 253
762x787x1270 182
762x787x1270 70
70
B100
£1840 B100
£1840 421£1995
304 421
1219x787x1270 304
1219x787x1270 105
105
B120
£4000 B120
£4000 542£4340
406 542
1219x864x1372 406
1219x864x1372 136
136
B25
£875
Application ARI BinBin Storage Storage KgsKg
Ice Machines - Incoming Water Supply Minimum incoming water temperature: 40°F (4.5°C) Maximum incoming water temperature: 100°F (38°C) Minimum incoming water pressure: 20 psi (1.4 bar) Maximum incoming water pressure: 80 psi (4.1 bar) Note: If water pressure exceeds 80 psi a water pressure regulator must be installed.
Ice machine Cleaner and Sanitizer Ice is a food product. Scientific research has also shown that certain bacteria and viruses can survive freezing for many hours and can also remain capable of growth in very strong alcoholic drinks. It is therefore important that ice does not become contaminated by airborne particles, food handlers or dirty utensils. The most likely sources of contamination of ice are inadequate cleaning of the ice making machine or equipment and poor hygiene practices when handling the ice. The ice storage compartment should be cleaned regularly, at least fortnightly, to prevent the build up of bacteria. It should be monitored for any growth of scum or slime and if such growths become apparent, it should be immediately cleaned according to the manufacturer’s instructions.
Optional extras and accessories. Accessories
Description
Order Code
Price
Ice Machine Descaler & Sanitiser
All models 6 x 500ml bottles of cleaner and 2 x 750ml spray sanitiser
IMDS1
£99.00
Bin Adaptor Kit
Adaptor kit for GEM0655, MFI0805, MFI1255 or 559mm ice series on a 762mm bin
KBT19
£252.00
January 2013
12
13 www.classeq.co.uk
Warewashers
January 2013
14
Electrical Technical Data Single Phase Model Eco 1 Eco 2 Eco 3 Duo 2 Duo 3 Hydro 400 Hydro 700 Hydro 750 Duo 400 Duo 750 Hydro 857
Max. KW Loading
Max. Amps per Phase
Hot
Cold
13
2.92 2.92 6.84 2.92 6.84 2.92 3.44 6.84 2.92 6.84 6.84
13 13 32 13 32 13 13 32 13 32 32
4 4 4 4 4 4 4 4 4 4 4
4 4 4 4 4 4 4 4 4 4 4
4 4 4* 4 4* 4 4 4* 4 4*
Max. KW Loading
Max. Amps per Phase
Hot
Cold
16
6.84 6.84 6.84 6.84 6.84 9.48 12.84 13.3 22.8 19.7 29.2 17.5 27 23.9 33.4 21.2 30.7 27.6 37.1 20.5 30 26.9 36.4 25.3 34.8 31.7 41.2 31.8 41.3 38.2 47.7 7.1 7.4 8 11 15.5
13 13 13 13 13 17 22 19 32 28 41 25 38 33 46 30 43 38 52 29 42 38 51 35 48 44 57 44 57 53 66 10 10 11 15 21
4 4 4 4 4 4 4 4
4 4 4 4 4 4 4
4 4 4 4 4
20
25
32
4*
4
4*
4
4*
4
4*
4 4
40
45
40
45
Three Phase Model Eco 3 Hydro 750 Hydro 857 Duo 3 Duo 750 Hydro 957 Hydro 957AS Alto 100 Alto 100 Alto 100 D/CD Alto 100 D/CD Alto 130 Alto 130 Alto 130 D/CD Alto 130 D/CD Alto 170/CP Alto 170/CP Alto 170 D/CD/CPD/CPCD Alto 170 D/CD/CPD/CPCD Alto 170X Alto 170X Alto 170X D/CD Alto 170X D/CD Alto 220/CP Alto 220/CP Alto 220 D/CD/CPD/CPCD Alto 220 D/CD/CPD/CPCD Alto 280/CP Alto 280/CP Alto 280 D/CD/CPD/CPCD Alto 280 D/CD/CPD/CPCD Viso 50 Viso 55 Viso 55H Viso 70 Viso 132
19
25
32
80
4 4 4
4
4
4
4 4
4
4
4 4
4 4
4 4
4
4
4 4
4
4
4 4
4
4
4 4
4
4
4 4
4
4
4 4
4 4 4 4 4 4
4 4 4 4 4 4 4 4 4 4
63
4 4 4 4 4 4
4 4 4 4 4 4
* Down rated loading. Please note: Down rating of rinse boiler elements will increase the length of the wash cycle due to boiler recovery requirements. 15 www.classeq.co.uk
Water Treatment The following tables highlight the recommended water softener unit needed, depending upon the machine being specified and the ideal hardness (mineral content) of the incoming water supply. This information should be used as a general guide only. Full technical support and advice is available through your Classeq Area Sales Manager. Water Softeners
Front loading Glasswashers
Front loading Dishwashers
Pass Through Dishwashers Rack Conveyors
Utensil Washers
Eco 1 Eco 2 Eco 3 Duo 2 Duo 3 Hydro 400 Hydro 700 Hydro 750 Duo 400 Duo 750 Hydro 857 Hydro 957 ALTO 100 ALTO 130 ALTO 170 ALTO 170X ALTO 220 ALTO 280 Viso 50 Viso 55 Viso 55H Viso 70 Viso 132
8-litre manual 4 -
12-litre manual 4 4 4 4 4 -
16-litre manual 4 4 4 4 4 -
20-litre manual 4 4 -
Auto softener 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4
DuoMatik Softener 4 4 4 4 4 4 -
January 2013
16
Water Treatment - Base Exchange Water Softeners Water treatment is essential in order to achieve good washing results. It will reduce detergent consumption to a minimum and help prevent failure of heating elements and rinse jet blockages, caused by the formation of calcium carbonate (lime scale) deposits. Failure to install a water softener where appropriate can affect the machine warranty terms. Wherever the total hardness of the water exceeds 7° Clark (100 ppm), a base exchange water softener is recommended for all warewashing machines. Model Type
Description
Order Code
WS8
• • • • • • • • •
WS8-SK
£110.00
WS12
• • • • • • • •
Manual softener Cylinder type 12 litre capacity Stainless steel construction Flexible hose fitted No electric supply required Dimensions: 520(h) × 180(dia) Compatible with the Eco 2, Duo 2, Hydro 400 and Duo 400 models • Typical softening capacity: 1800 litres
WS12-SK
£124.00
WS16
• • • • • • • •
Manual softener Cylinder type 16 litre capacity Stainless steel construction Flexible hose fitted No electric supply required Dimensions: 620(h) × 180(dia) Compatible with the Eco 3, Duo 3, Hydro 700, Hydro 750 and Duo 750 models • Typical softening capacity: 2300 litres
WS16-SK
£136.00
WS20
• • • • • • • •
WS20-SK
£179.00
Manual softener Cylinder type 8 litre capacity Stainless steel construction Flexible hose fitted No electric supply required Dimensions: 415(h) × 180(dia) Compatible with the EC01 models Typical softening capacity: 1500 litres
Manual softener Cylinder type 20 litre capacity Stainless steel construction Flexible hose fitted No electric supply required Dimensions: 900(h) × 180(dia) Compatible with the Hydro 850, Hydro 900 models H800 and RC models • Typical softening capacity: 3300 litres
17 www.classeq.co.uk
Price
WSAUTO
• • • • • • • • •
Automatic softener Brine tank system 500-800 litre capacity Reinforced plastic construction Water feed must not exceed 35°C Flexible hose fitted Electric supply required Dimensions: 230(w) × 420(d) × 545(h) To be used with tablet salt
WS-Auto
£695.00
WSHC10
• • • • • • • • •
Automatic softener Brine tank system 500-800 litre capacity Reinforced plastic construction Water feed must not exceed 60°C Flexible hose Electric supply required Dimensions: 275(w) × 450(d) × 640(h) To be used with tablet salt
WS-HC10
£930.00
DuoMatik
• • • • • • • • • • •
Automatic softener Cabinet type Fibre glass cartridge High density plastic container Water feed must not exceed 50°C Flexible armoured hose fitted For continuous operation Mobile Capacity between regenerations: n/a No electric supply required Dimensions: 360(w) × 500(d) × 790(h)
51-01-206
£1585.00
Optional extras and accessories. Accessories
Description
Order Code
Price
Salt
Tablet salt for DuoMatik softener 25kg Granulated 25kg
SALT T SALT
Boostermatic
Pressure pump (required where water pressure is below 45psi/3 bar)
99-05-039
£655.00
Fixing bracket
For pump
99-05-002
£37.00
Mixer valve
For hot water installations
99-32-001
£160.00
£17.00 £17.00
January 2013
18
Eco Glasswashers High volume glasswashers with built in chemical dispensers. Single piece wash arms provide highly effective wash action for up to 750 glasses per hour. Reduced water consumption, via 10 or 18 litre wash tanks, ensures minimised running costs. Double skinned door reduces heat loss and lessens noise in operation. Removable rack guides and wash chamber door allow easy cleaning and excellent service access.
Optional extras and accessories. Accessories
Description
Order Code
Salt (granulated)
25kg
SALT
Stands
Eco 1/2 stainless steel 457(w) × 497(d) × 410(h) Eco 3 stainless steel 555(w) × 550(d) × 410(h) Steel coated stand (for Eco 1) 410(w) × 490(d) × 440(h) Steel coated stand (for Eco 2) 435(w) × 490(d) × 440(h) Steel coated stand (for Eco 3) 535(w) × 545(d) × 440(h)
SS-400 SS-500 BWS350 BWS400 BWS500
Baskets
Eco 1 glass Eco 2 glass Eco 3 glass
400SGB-P 500GBP 700GBP
£36.00 £36.00 £36.00
Baskets Inserts
Wire plate holder (Eco 2)
500DRI
£31.00
Water Softener
8 litre 12 litre 16 litre 20 litre Automatic
WS8-SK WS12-SK WS16-SK WS20-SK WSAUTO
Glasswashing
Super clean glasswashing detergent 2 x 5l G3 glass rejuvenator 1 × 10kg Super shine glasswashing rinse aid 2 x 5l Glasswashing starter pack - Glasswash detergent 2 × 5l - Rinse aid 2 × 5l
GW2-5 G3/10 GWRA2-5
£28.00 £71.00 £23.00
SPG
£48.00
19 www.classeq.co.uk
Price
£17.00 £197.00 £218.00 £95.00 £95.00 £95.00
£110.00 £124.00 £136.00 £179.00 £695.00
Eco 1
Eco 2
Eco 3
Specifications
Specifications
Specifications
Width ____________________________________ 410 mm Depth ____________________________________ 512 mm Depth – door open ________________________ 809 mm Height ________________________________ 640-660 mm Rack size (square)__________________________ 350 mm Maximum pints per rack _________________________ 12 Door opening height ______________________ 330 mm Maximum clear entry height________________ 320 mm Operating level _____________________________ <70 db Net weight __________________________________ 35 kg Gross weight ________________________________ 40 kg Built in rinse aid dispenser ______________________ Yes Double skinned door __________________________ Yes Maximum racks per hour water @50˚C ____________ 30 Cycle times __________________________________ 2 min Water connection - BSP ________________________ 3/4" Water inlet height from floor level ___________ 40 mm Required water pressure (flow) ________________ 2 bar Required water flow ____________________ 11 Ltrs/min Drain type ___________ Gravity (optional drain pump) Drain size __________________________________ 35 mm Operating voltage - 220/50/1______________________________________ Std - 400/50/3 ______________________________________ No Amps required - 1 phase - Water fed @ 40º C _______________________ 13 Amps - Water fed @ 10º C _______________________ 13 Amps Total Connected Load - Water fed @ 10º C ________________________ 2.92 kW - Water fed @ 40º C ________________________ 2.92 kW Temperature interlock _________ Yes (can be removed) Quick start mode_______________________________ Yes Wash tank heating__________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C _________________________ 2.6 kW - Water fed @ 40º C _________________________ 2.6 kW Wash pump size ___________________________ 0.22 kW Wash pump capacity ___________________ 220 Ltrs/min Wash tank capacity__________________________ 10 Ltrs Wash tank operating temperature______________ 55˚C Rinse boiler capacity ________________________ 6.5 Ltrs Rinse boiler operating temperature_____________ 70˚C Rinse water consumption - @ 2 Bar__________ 3.25 Ltrs Max/Min stand pipe height from floor _____ 0-600mm Max/Min water pressure _________________ 6 bar/1 bar Minimum water flow_____________________ 8 Ltrs/min
Width ____________________________________ 450 mm Depth ____________________________________ 535 mm Depth – door open ________________________ 860 mm Height ________________________________ 740-760 mm Rack size (square)__________________________ 400 mm Maximum pints per rack _________________________ 16 Door opening height ______________________ 330 mm Maximum clear entry height________________ 320 mm Operating level _____________________________ <70 db Net weight __________________________________ 35 kg Gross weight ________________________________ 40 kg Built in rinse aid dispenser ______________________ Yes Double skinned door __________________________ Yes Maximum racks per hour water @50˚C ____________ 30 Cycle times __________________________________ 2 min Water connection - BSP ________________________ 3/4" Water inlet height from floor level ___________ 40 mm Required water pressure (flow) ________________ 2 bar Required water flow ____________________ 11 Ltrs/min Drain type ___________ Gravity (optional drain pump) Drain size __________________________________ 35 mm Operating voltage - 220/50/1______________________________________ Std - 400/50/3 ______________________________________ No Amps required - 1 phase - Water fed @ 40º C _______________________ 13 Amps - Water fed @ 10º C _______________________ 13 Amps Total Connected Load - Water fed @ 10º C ________________________ 2.92 kW - Water fed @ 40º C ________________________ 2.92 kW Temperature interlock _________ Yes (can be removed) Quick start mode_______________________________ Yes Wash tank heating__________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C _________________________ 2.6 kW - Water fed @ 40º C _________________________ 2.6 kW Wash pump size ___________________________ 0.22 kW Wash pump capacity ___________________ 220 Ltrs/min Wash tank capacity__________________________ 10 Ltrs Wash tank operating temperature______________ 55˚C Rinse boiler capacity ________________________ 6.5 Ltrs Rinse boiler operating temperature_____________ 70˚C Rinse water consumption - @ 2 Bar__________ 3.25 Ltrs Max/Min stand pipe height from floor _____ 0-600mm Max/Min water pressure _________________ 6 bar/1 bar Minimum water flow_____________________ 8 Ltrs/min
Width ____________________________________ 550 mm Depth ____________________________________ 625 mm Depth – door open ________________________ 985 mm Height ________________________________ 825-845 mm Rack size (Square) _________________________ 500 mm Maximum pints per rack _________________________ 25 Door opening height ______________________ 360 mm Maximum clear entry height________________ 345 mm Operating level _____________________________ <70 db Net Weight__________________________________ 60 kg Gross Weight ________________________________ 65 kg Built in rinse aid dispenser ______________________ Yes Double skinned door __________________________ Yes Maximum racks per hour water @50˚C ____________ 30 Cycle times __________________________________ 2 min Water connection - BSP ________________________ 3/4" Water inlet height from floor level ___________ 40 mm Required water pressure (flow) ________________ 2 bar Required water flow ____________________ 11 Ltrs/min Drain type ___________ Gravity (optional drain pump) Drain size __________________________________ 35 mm Operating voltage - 220/50/1______________________________________ Std - 400/50/3 ________________________________ Optional Amps required - 1 phase - Water fed @ 40º C _______________________ 32 Amps - Water fed @ 10º C _______________________ 32 Amps Amps required - 3 phase - Water fed @ 40º C _______________________ 13 Amps - Water fed @ 10º C _______________________ 13 Amps Total Connected Load - Water fed @ 10º C ________________________ 6.84 kW - Water fed @ 40º C ________________________ 6.84 kW Temperature interlock _________ Yes (can be removed) Quick start mode_______________________________ Yes Wash tank heating__________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C _________________________ 6.0 kW - Water fed @ 40º C _________________________ 6.0 kW Wash pump size ___________________________ 0.74 kW Wash pump capacity ___________________ 380 Ltrs/min Wash tank capacity__________________________ 18 Ltrs Wash tank operating temperature______________ 55˚C Rinse boiler capacity ________________________ 7.5 Ltrs Rinse boiler operating temperature_____________ 70˚C Rinse water consumption - @ 2 Bar__________ 3.25 Ltrs Max/Min stand pipe height from floor _____ 0-600mm Max/Min water pressure _________________ 6 bar/1 bar Minimum water flow_____________________ 8 Ltrs/min
ECO1 (2.75kW) Gravity drain machine.
£1355.00
ECO2 (2.75kW) Gravity drain machine.
£1670.00
ECO3M (6.75kW) Gravity drain machine.
£2665.00
ECO1P (2.75kW) With fitted drain pump.
£1555.00
ECO2P (2.75kW) With fitted drain pump.
£1880.00
ECO3(6.75kW) With fitted drain pump.
£2870.00
ECO3M-13A 13 amp hot fill recommended
£2665.00
ECO3-13A 13 amp hot fill recommended
£2870.00
January 2013
20
Duo Glasswashers High volume glasswashers with built in chemical dispensers. Single piece wash arms provide highly effective wash action for up to 750 glasses per hour. Reduced water consumption, via 10 or 18 litre wash tanks, ensures minimised running costs. Double skinned cabinet reduces heat loss and lessens noise in operation. Removable rack guides and wash chamber door allow easy cleaning and excellent service access. All machines complete with drain pump, rinse pump and WRAS approved air gap for simple and compliant installation.
Optional extras and accessories. Accessories
Description
Order Code
Salt (granulated)
25kg
SALT
Stands
Duo 2 stainless steel 477(w) × 499(d) × 421(h) Duo 3 stainless steel 575(w) × 552(d) × 421(h) Steel coated stand (for Duo 2) 435(w) × 490(d) × 440(h) Steel coated stand (for Duo 3) 535(w) × 545(d) × 440(h)
SS-400D SS-500D BWS400 BWS500
£197.00 £218.00 £95.00 £95.00
Baskets
Duo 2 glass Duo 3 glass
500GBP 700GBP
£36.00 £36.00
Baskets Inserts
Wire plate holder (Duo 2)
500DRI
£31.00
Water Softener
8 litre 12 litre 16 litre 20 litre Automatic
WS8-SK WS12-SK WS16-SK WS20-SK WSAUTO
Glasswashing
Super clean glasswashing detergent 2 x 5l G3 glass rejuvenator 1 × 10kg Super shine glasswashing rinse aid 2 x 5l Glasswashing starter pack - Glasswash detergent 2 × 5l - Rinse aid 2 × 5l
GW2-5 G3/10 GWRA2-5
£28.00 £71.00 £23.00
SPG
£48.00
21 www.classeq.co.uk
Price
£17.00
£110.00 £124.00 £136.00 £179.00 £695.00
Duo 2
Duo 3 Available with integral softener
Specifications
Specifications
Width _______________________________________________________ 470 mm Depth _______________________________________________________ 535 mm Depth – door open ___________________________________________ 860 mm Height ___________________________________________________ 750-770mm Rack size (square) ____________________________________________ 400 mm Maximum pints per rack ___________________________________________ 16 Door opening height _________________________________________ 330 mm Maximum clear entry height __________________________________ 320 mm Operating level ________________________________________________ 70 db Net weight ____________________________________________________ 38 kg Gross weight ___________________________________________________ 43 kg Built in air gap (water council approved - WRC) _____________________ Yes Rinse booster pump ______________________________________________ Yes Built in detergent dispenser _______________________________________ Yes Built in rinse aid dispenser_________________________________________ Yes Double skinned cabinet ___________________________________________ Yes Maximum racks per hour - water @50˚C _____________________________ 30 Cycle times ____________________________________________________ 2 min Water connection - BSP __________________________________________ 3/4" Water inlet height from floor level _____________________________ 40 mm Required water pressure (flow) _________________________________ 0.5 bar Required water flow ________________________________________ 8 Ltrs/min Drain type __________________________________________________ pumped Drain size_____________________________________________________ 22 mm Operating voltage - 220/50/1 ________________________________________________________ Std - 400/50/3 ________________________________________________________ No Amps required - 1 phase - Water fed @ 40º C __________________________________________ 13 Amps - Water fed @ 10º C __________________________________________ 13 Amps Total Connected Load - Water fed @ 10º C __________________________________________ 2.92 kW - Water fed @ 40º C __________________________________________ 2.92 kW Temperature interlock ___________________________ Yes (can be removed) Quick start mode _________________________________________________ Yes Wash tank heating ____________________________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C ___________________________________________ 2.6 kW - Water fed @ 40º C ___________________________________________ 2.6 kW Wash pump size _____________________________________________ 0.22 kW Wash pump capacity______________________________________ 220 Ltrs/min Wash tank capacity ____________________________________________ 10 Ltrs Wash tank operating temperature ________________________________ 55˚C Rinse boiler capacity __________________________________________ 6.5 Ltrs Rinse boiler operating temperature _______________________________ 70˚C Rinse water consumption - @ 2 Bar ____________________________ 3.25 Ltrs Max/Min stand pipe height from floor ________________________ 0-600mm Max/Min water pressure __________________________________ 6 bar/0.5 bar Minimum water flow _____________________________________ 2.5 Ltrs/min
Width _______________________________________________________ 570 mm Depth _______________________________________________________ 625 mm Depth – door open ___________________________________________ 985 mm Height __________________________________________________ 835-855 mm Rack size (Square) ____________________________________________ 500 mm Maximum pints per rack ___________________________________________ 25 Door opening height _________________________________________ 360 mm Maximum clear entry height __________________________________ 345 mm Operating level ________________________________________________ 70 db Net Weight ____________________________________________________ 65 kg Gross Weight___________________________________________________ 70 kg Built in air gap (water council approved - WRC) _____________________ Yes Rinse booster pump ______________________________________________ Yes Built in detergent dispenser _______________________________________ Yes Built in rinse aid dispenser_________________________________________ Yes Integrated water softener____________________________________ Optional Double skinned cabinet ___________________________________________ Yes Maximum racks per hour - water @50˚C_____________________________ 30 Cycle times ____________________________________________________ 2 min Water connection - BSP __________________________________________ 3/4" Water inlet height from floor level _____________________________ 40 mm Required water pressure (flow) _________________________________ 0.5 bar Required water flow ________________________________________ 8 Ltrs/min Drain type __________________________________________________ pumped Drain size_____________________________________________________ 22 mm Operating voltage - 220/50/1 ________________________________________________________ Std - 400/50/3 ___________________________________________________ Optional Amps required - 1 phase - Water fed @ 40º C __________________________________________ 13 Amps - Water fed @ 10º C __________________________________________ 13 Amps Amps required - 3 phase - Water fed @ 40º C __________________________________________ 32 Amps - Water fed @ 10º C __________________________________________ 32 Amps Total Connected Load - Water fed @ 10º C __________________________________________ 6.84 kW - Water fed @ 40º C __________________________________________ 6.84 kW Temperature interlock ___________________________ Yes (can be removed) Quick start mode _________________________________________________ Yes Wash tank heating ____________________________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C ___________________________________________ 6.0 kW - Water fed @ 40º C ___________________________________________ 6.0 kW Wash pump size _____________________________________________ 0.74 kW Wash pump capacity______________________________________ 380 Ltrs/min Wash tank capacity ____________________________________________ 18 Ltrs Wash tank operating temperature ________________________________ 55˚C Rinse boiler capacity __________________________________________ 7.5 Ltrs Rinse boiler operating temperature _______________________________ 70˚C Rinse water consumption - @ 2 Bar ____________________________ 3.25 Ltrs Max/Min stand pipe height from floor ________________________ 0-600mm Max/Min water pressure __________________________________ 6 bar/0.5 bar Minimum water flow _____________________________________ 2.5 Ltrs/min
DUO2 (2.75kW)
£2025.00
DUO3 (6.75kW) DUO3/WS (6.75kW)*
£3155.00 £3665.00
DUO3-13A DUO3/WS-13A* 13 amp hot fill recommended
£3155.00 £3665.00
* With integral water softener (minimum water pressure of 1.5 bar required). Max water temp 60˚C
January 2013
22
Hydro Dishwashers Front loading
High volume dishwashers with built in chemical dispensers. Single piece wash arms provide highly effective wash action for up to 360 plates per hour. Reduced water consumption, via 10 or 18 litre wash tanks, ensures minimised running costs. Double skinned cabinet reduces heat loss and lessens noise in operation. Removable rack guides and wash chamber door allow easy cleaning and excellent service access.
Optional extras and accessories. Accessories
Description
Order Code
Salt (granulated)
25kg
SALT
Stands
Hydro 400 stainless steel 457(w) × 497(d) × 410(h) Hydro 750 stainless steel 555(w) × 550(d) × 410(h) Steel coated stand (for Hydro 500) 435(w) × 490(d) × 440(h) Steel coated stand (for Hydro 700, Hydro 750) 535(w) × 545(d) × 440(h)
SS-400 SS-500 BWS400 BWS500
£197.00 £218.00 £95.00 £95.00
Baskets
Hydro 400 plate Hydro 400 cup Hydro 750 plate Hydro 750 cup Hydro 8 compartment cutlery
500PRP 500GBP 700DRP 700GBP CBP
£36.00 £36.00 £36.00 £36.00 £36.00
Baskets Inserts
Wire plate holder
500DRI
£36.00
Water Softener
8 litre 12 litre 16 litre 20 litre Automatic
WS8-SK WS12-SK WS16-SK WS20-SK WSAUTO
Dishwashing
Super clean dishwashing detergent 2 x 5l Super clean dishwashing detergent 1 x 20l Super clean dishwashing rinse aid 2 x 5l Super clean dishwashing rinse aid 1 x 20l Dishwashing starter pack - Detergent 2 × 5l - Rinse aid 2 × 5l
DW2-5 DW1-20 DWRA2-5 DWRA1-20
£28.00 £52.00 £23.00 £45.00
SPD
£48.00
23 www.classeq.co.uk
Price
£17.00
£110.00 £124.00 £136.00 £179.00 £695.00
Hydro 400
Hydro 700
Hydro 750
Specifications
Specifications
Specifications
Width ____________________________________ 450 mm Depth ____________________________________ 535 mm Depth – door open ________________________ 860 mm Height ________________________________ 740-760 mm Rack size (square)__________________________ 400 mm Maximum plates per rack _________________________ 9 Door opening height ______________________ 330 mm Maximum clear entry height________________ 315 mm Operating level _____________________________ <70 db Net weight __________________________________ 35 kg Gross weight ________________________________ 40 kg Built in detergent dispenser_____________________ Yes Built in rinse aid dispenser ______________________ Yes Double skinned door __________________________ Yes Maximum racks per hour - water @50˚C __________ 20 Cycle times _________________________________ 3 min Water connection - BSP ________________________ 3/4" Water inlet height from floor level __________________________________ 40 mm Required water pressure (flow) ________________ 2 bar Required water flow ____________________ 11 Ltrs/min Drain Type ____________ Gravity (optional drain pump) Drain size___________________________________ 35mm Operating voltage - 220/50/1______________________________________ Std - 400/50/3 ______________________________________ No Amps required - 1 phase - Water fed @ 40º C _______________________ 13 Amps - Water fed @ 10º C _______________________ 13 Amps Total Connected Load - Water fed @ 10º C ________________________ 2.92 kW - Water fed @ 40º C ________________________ 2.92 kW Temperature interlock _________ Yes (can be removed) Quick start mode_______________________________ Yes Wash tank heating__________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C _________________________ 2.6 kW - Water fed @ 40º C _________________________ 2.6 kW Wash pump size ___________________________ 0.22 kW Wash pump capacity ___________________ 220 Ltrs/min Wash tank capacity__________________________ 10 Ltrs Wash tank operating temperature __________________________________ 55˚C Rinse boiler capacity ________________________ 6.5 Ltrs Rinse boiler operating temperature __________________________________ 80˚C Rinse water consumption - @ 2 Bar__________________________________ 3.25 Ltrs Max/Min stand pipe height from floor _____ 0-600mm Max/Min water pressure _________________ 6 bar/1 bar Minimum water flow_____________________ 8 Ltrs/min
Width ____________________________________ 550 mm Depth ____________________________________ 625 mm Depth – door open ________________________ 985 mm Height ________________________________ 825-845 mm Rack size (square)__________________________ 500 mm Maximum plates per rack ________________________ 18 Door opening height ______________________ 360 mm Maximum clear entry height _______________ 345 mm Operating level _____________________________ <70 db Net weight __________________________________ 60 kg Gross weight ________________________________ 65 kg Built in detergent dispenser_____________________ Yes Built in rinse aid dispenser ______________________ Yes Double skinned door __________________________ Yes Maximum racks per hour - water @50˚C __________ 20 Cycle times _________________________________ 3 min Water connection - BSP ________________________ 3/4" Water inlet height from floor level __________________________________ 40 mm Required water pressure (flow) ________________ 2 bar Required water flow ____________________ 11 Ltrs/min Drain Type ____________ Gravity (optional drain pump) Drain size__________________________________ 35 mm Operating voltage - 220/50/1______________________________________ Std - 400/50/3 ______________________________________ No Amps required - 1 phase - Water fed @ 40º C _______________________ 13 Amps - Water fed @ 10º C _______________________ 13 Amps Total Connected Load - Water fed @ 10º C ________________________ 3.44 kW - Water fed @ 40º C ________________________ 3.44 kW Temperature interlock _________ Yes (can be removed) Quick start mode_______________________________ Yes Wash tank heating__________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C _________________________ 2.6 kW - Water fed @ 40º C _________________________ 2.6 kW Wash pump size ___________________________ 0.74 kW Wash pump capacity ___________________ 380 Ltrs/min Wash tank capacity__________________________ 18 Ltrs Wash tank operating temperature __________________________________ 55˚C Rinse boiler capacity ________________________ 7.5 Ltrs Rinse boiler operating temperature __________________________________ 80˚C Rinse water consumption - @2 Bar __________________________________ 3.25 Ltrs Max/Min stand pipe height from floor _____ 0-600mm Max/Min water pressure _________________ 6 bar/1 bar Minimum water flow_____________________ 8 Ltrs/min
Width ____________________________________ 550 mm Depth ____________________________________ 625 mm Depth – door open ________________________ 985 mm Height ________________________________ 825-845 mm Rack size (square)__________________________ 500 mm Maximum plates per rack ________________________ 18 Door opening height ______________________ 360 mm Maximum clear entry height _______________ 345 mm Operating level _____________________________ <70 db Net weight __________________________________ 60 kg Gross weight ________________________________ 65 kg Built in detergent dispenser_____________________ Yes Built in rinse aid dispenser ______________________ Yes Double skinned door __________________________ Yes Maximum racks per hour - water @50˚C __________ 20 Cycle times _________________________________ 3 min Water connection - BSP ________________________ 3/4" Water inlet height from floor level __________________________________ 40 mm Required water pressure (flow) ________________ 2 bar Required water flow ____________________ 11 Ltrs/min Drain Type ____________ Gravity (optional drain pump) Drain size__________________________________ 35 mm Operating voltage - 220/50/1______________________________________ Std - 400/50/3 ________________________________ Optional Amps required - 1 phase - Water fed @ 40º C _______________________ 32 Amps - Water fed @ 10º C _______________________ 32 Amps Amps required - 3 phase - Water fed @ 40º C _______________________ 13 Amps - Water fed @ 10º C _______________________ 13 Amps Total Connected Load - Water fed @ 10º C ________________________ 6.84 kW - Water fed @ 40º C ________________________ 6.84 kW Temperature interlock _________ Yes (can be removed) Quick start mode_______________________________ Yes Wash tank heating__________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C _________________________ 6.0 kW - Water fed @ 40º C _________________________ 6.0 kW Wash pump size ___________________________ 0.74 kW Wash pump capacity ___________________ 380 Ltrs/min Wash tank capacity__________________________ 18 Ltrs Wash tank operating temperature __________________________________ 55˚C Rinse boiler capacity ________________________ 7.5 Ltrs Rinse boiler operating temperature __________________________________ 80˚C Rinse water consumption - @ 2 Bar__________________________________ 3.25 Ltrs Max/Min stand pipe height from floor _____ 0-600mm Max/Min water pressure _________________ 6 bar/1 bar Minimum water flow_____________________ 8 Ltrs/min
H400 (2.75kW) Gravity drain machine.
£2305.00
H700 (2.75kW) Gravity drain machine.
£2535.00
H400P (2.75kW) With fitted drain pump.
£2505.00
H700P (2.75kW) With fitted drain pump.
£2740.00
H750M (6.75kW) Gravity drain machine. H750 (6.75kW) With fitted drain pump. H750M-13A 13 amp hot fill recommended H750-13A 13 amp hot fill recommended
£2735.00 £2950.00 £2735.00 £2950.00
January 2013
24
Duo Dishwashers Front loading
High volume dishwashers with built in chemical dispensers. Single piece wash arms provide highly effective wash action for up to 750 dishes per hour. Reduced water consumption, via 10 or 18 litre wash tanks, ensures minimised running costs. Double skinned cabinet reduces heat loss and lessens noise in operation. Removable rack guides and wash chamber door allow easy cleaning and excellent service access. All machines complete with drain pump, rinse pump and WRAS approved air gap for simple and compliant installation.
Optional extras and accessories. Accessories
Description
Order Code
Salt (granulated)
25kg
SALT
Stands
Duo 400 stainless steel 477(w) × 499(d) × 421(h) Duo 750 stainless steel 575(w) × 552(d) × 421(h) Steel coated stand (for Duo 400) 435(w) × 490(d) × 440(h) Steel coated stand (for Duo 750) 535(w) × 545(d) × 440(h)
SS-400D SS-500D BWS400 BWS500
£197.00 £218.00 £95.00 £95.00
Water Softener
8 litre 12 litre 16 litre 20 litre Automatic
WS8-SK WS12-SK WS16-SK WS20-SK WSAUTO
£110.00 £124.00 £136.00 £179.00 £695.00
Dishwashing
Super clean dishwashing detergent 2 x 5l Super clean dishwashing detergent 1 x 20l Super clean dishwashing rinse aid 2 x 5l Super clean dishwashing rinse aid 1 x 20l Dishwashing starter pack - Detergent 2 × 5l - Rinse aid 2 × 5l
DW2-5 DW1-20 DWRA2-5 DWRA1-20
£28.00 £52.00 £23.00 £45.00
SPD
£48.00
25 www.classeq.co.uk
Price
£17.00
Duo 400
Duo 750 Available with integral softener
Specifications
Specifications
Width _______________________________________________________ 470 mm Depth _______________________________________________________ 535 mm Depth - door open ___________________________________________ 860 mm Height __________________________________________________ 750-770 mm Rack size (square) ____________________________________________ 400 mm Maximum plates per rack ___________________________________________ 9 Door opening height ________________________________________ 330 mm Maximum clear entry height __________________________________ 315 mm Operating level ________________________________________________ 70 db Net weight ____________________________________________________ 38 kg Gross weight ___________________________________________________ 43 kg Built in air gap (water council approved - WRC) _____________________ Yes Rinse booster pump ______________________________________________ Yes Built in detergent dispenser _______________________________________ Yes Built in rinse aid dispenser_________________________________________ Yes Double skinned cabinet __________________________________________ Yes Maximum racks per hour - water @50˚C _____________________________ 20 Cycle times ____________________________________________________ 3 min Water connection - BSP __________________________________________ 3/4" Water inlet height from floor level _____________________________ 40 mm Required water pressure (flow) __________________________________ 2 bar Required water flow ________________________________________ 8 Ltrs/min Drain type __________________________________________________ pumped Drain size ____________________________________________________ 22 mm Operating voltage - 220/50/1 ________________________________________________________ Std - 400/50/3 ________________________________________________________ No Amps required - 1 phase - Water fed @ 40º C __________________________________________ 13 Amps - Water fed @ 10º C __________________________________________ 13 Amps Total Connected Load - Water fed @ 10º C __________________________________________ 2.92 kW - Water fed @ 40º C __________________________________________ 2.92 kW Temperature interlock ____________________________________________ Yes Wash tank heating ____________________________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C ___________________________________________ 2.6 kW - Water fed @ 40º C ___________________________________________ 2.6 kW Wash pump size _____________________________________________ 0.22 kW Wash pump capacity______________________________________ 220 Ltrs/min Wash tank capacity ____________________________________________ 10 Ltrs Wash tank operating temperature ________________________________ 55˚C Rinse boiler capacity __________________________________________ 6.5 Ltrs Rinse boiler operating temperature _______________________________ 80˚C Rinse water consumption - @ 2 Bar ____________________________ 3.25 Ltrs Max/Min stand pipe height from floor ________________________ 0-600mm Max/Min water pressure __________________________________ 6 bar/0.5 bar Minimum water flow _____________________________________ 2.5 Ltrs/min
Width ______________________________________________________ 570 mm Depth ______________________________________________________ 625 mm Depth - door open ___________________________________________ 985 mm Height __________________________________________________ 835-855 mm Rack size (square)____________________________________________ 500 mm Maximum plates per rack __________________________________________ 18 Door opening height ________________________________________ 360 mm Maximum clear entry height _________________________________ 345 mm Operating level ________________________________________________ 70 db Net weight ___________________________________________________ 65 kg Gross weight __________________________________________________ 70 kg Built in air gap (water council approved - WRC)_____________________ Yes Rinse booster pump _____________________________________________ Yes Built in detergent dispenser_______________________________________ Yes Built in rinse aid dispenser ________________________________________ Yes Integrated water softener____________________________________ Optional Double skinned cabinet __________________________________________ Yes Maximum racks per hour - water @50˚C_____________________________ 20 Cycle times ____________________________________________________ 3 min Water connection - BSP __________________________________________ 3/4" Water inlet height from floor level _____________________________ 40 mm Required water pressure (flow) __________________________________ 2 bar Required water flow _______________________________________ 8 Ltrs/min Drain type __________________________________________________ pumped Drain size ____________________________________________________ 22 mm Operating voltage - 220/50/1________________________________________________________ Std - 400/50/3 __________________________________________________ Optional Amps required - 1 phase - Water fed @ 40º C __________________________________________ 32 Amps - Water fed @ 10º C __________________________________________ 32 Amps Amps required - 3 phase - Water fed @ 40º C __________________________________________ 13 Amps - Water fed @ 10º C __________________________________________ 13 Amps Total Connected Load - Water fed @ 10º C __________________________________________ 6.84 kW - Water fed @ 40º C __________________________________________ 6.84 kW Temperature interlock ____________________________________________ Yes Wash tank heating ___________________________________________ 2.0 kW Rinse boiler heating - Water fed @ 10º C ___________________________________________ 6.0 kW - Water fed @ 40º C ___________________________________________ 6.0 kW Wash pump size _____________________________________________ 0.74 kW Wash pump capacity _____________________________________ 380 Ltrs/min Wash tank capacity ___________________________________________ 18 Ltrs Wash tank operating temperature________________________________ 55˚C Rinse boiler capacity __________________________________________ 7.5 Ltrs Rinse boiler operating temperature_______________________________ 80˚C Rinse water consumption - @ 2 Bar____________________________ 3.25 Ltrs Max/Min stand pipe height from floor ________________________ 0-600mm Max/Min water pressure __________________________________ 6 bar/0.5 bar Minimum water flow _____________________________________ 2.5 Ltrs/min
DUO400 (2.75kW) Double skinned machine.
£2555.00
DUO750(6.7kW) DUO750/WS (6.7kW)* Double skinned machine.
£3215.00 £3725.00
DUO750-13A DUO750/WS-13A* 13 amp hot fill recommended
£3215.00 £3725.00
* With integral water softener (minimum water pressure of 1.5 bar required). Max water temp 60˚C
January 2013
26
Hydro
H857
Pass through Specification High volume dishwashers suitable for straight through or corner sited operation, these heavy duty machines are capable of washing up to 720 plates per hour. Reduced water consumption via 39 litre wash tank ensures minimised running costs. Easy cleaning due to the continuous hood clean, and the removable front panel allows excellent service access. All machines have drain pump fitted as standard and optional rinse pump, detergent pumps and WRAS type A air gap.
H857 £4650.00 Complete with drain pump, 3 Phase.
Optional extras and accessories. Accessories
Description
Order Code
Salt (granulated)
25kg
SALT
£17.00
Baskets
Hydro 857 plate Hydro 857 cup Hydro 957 plate Hydro 957 cup Hydro 8 compartment cutlery
700DRP 700GBP 700PRP 700GBP CBP
£36.00 £36.00 £36.00 £36.00 £36.00
Water treatment unit
20 litre Automatic Automatic hot water
WS20-SK WSAUTO WSHC10
Dishwashing
Super clean dishwashing detergent 2 x 5l Super clean dishwashing detergent 1 x 20l Super clean dishwashing rinse aid 2 x 5l Super clean dishwashing rinse aid 1 x 20l Dishwashing starter pack - Detergent 2 × 5l - Rinse aid 2 × 5l
DW2-5 DW1-20 DWRA2-5 DWRA1-20
£28.00 £52.00 £23.00 £45.00
SPD
£48.00
27 www.classeq.co.uk
Width________________________ 630 mm Depth________________________ 720 mm Height – hood open_____ 1890-1940 mm Height – hood closed____ 1470-1520 mm Rack size (square) _____________ 500 mm Maximum plates per rack ___________ 18 Maximum clear entry height ___ 385 mm Operating level ________________ <70 db Net weight ____________________ 130 kg Built in air gap ____________________ No (water council approved - WRC) Rinse booster pump __________ Optional Built in detergent dispenser ___ Optional Built in rinse aid dispenser ____ Optional Maximum racks per hour ___________ 40 Cycle Times (mins) _____________ 1½ or 3 Water connection - BSP ___________ 3/4" Water inlet height from floor level ________________ 265-315 mm Required water pressure (flow) ___ 2 bar Required water flow________ 11 Ltrs/min Drain Height from floor level Pump Drain_________________ 0-700 mm Drain size _____________________ 40 mm Drain Pump _________________ Standard Operating voltage - 220-240AC/50/1N____________ Optional - 380-415AC/50/3N ___________ Standard Amps required - 1 phase - Water fed @ 40º C __________ 30 Amps - Water fed @ 10º C ___________ 30 Amps Amps required - 3 phase - Water fed @ 40º C __________ 13 Amps - Water fed @ 10º C ___________ 13 Amps Total Connected Load 220-240AC/50/1N ______________ 6.84kW 380-415AC/50/3N ______________ 6.84kW Temperature Interlock _____________ Yes Wash tank heating____________ 4.05 kW Rinse boiler heating 220-240AC/50/1N ________________ 6 kW 380-415AC/50/3N ________________ 6 kW Wash pump size ______________ 0.74 kW Wash pump capacity ______ 380 Ltrs/min Wash tank capacity _____________ 39 Ltrs Wash tank operating temperature _____________________ 55˚C Rinse boiler capacity ___________ 7.5 Ltrs Rinse boiler operating temperature _____________________ 80˚C Rinse water consumption - @ 2 Bar _____________________ 3.25 Ltrs
Price
£179.00 £675.00 £930.00
H857/DET £4930.00 Complete with detergent and drain pump, 3 Phase. H857/1PH £4650.00 Single phrase, complete with drain pump.
£4930.00 H857/DET/1PH Single phrase, complete with detergent and drain pump.
H857A
H957
Available with integral softener
H957A Available with integral softener
H957AS Available with integral softener
Specification
Specification
Specification
Specification
Width________________________ 630 mm Depth________________________ 720 mm Height – hood open_____ 1890-1940 mm Height – hood closed____ 1470-1520 mm Rack size (square) _____________ 500 mm Maximum plates per rack ___________ 18 Maximum clear entry height ___ 385 mm Operating level ________________ <70 db Net weight ____________________ 130 kg Built in air gap ____________________ Yes (water council approved - WRC) Rinse booster pump _______________ Yes Built in detergent dispenser ___ Optional Built in rinse aid dispenser ____ Optional Maximum racks per hour ___________ 40 Cycle Times (mins) _____________ 1½ or 3 Water connection - BSP ___________ 3/4" Integrated water softener_____ Optional Water inlet height from floor level ________________ 265-315 mm Required water pressure (flow) ___ 2 bar Required water flow_________ 8 Ltrs/min Drain Height from floor level Pump Drain_________________ 0-700 mm Drain size _____________________ 40 mm Drain Pump _________________ Standard Operating voltage - 220-240AC/50/1N____________ Optional - 380-415AC/50/3N ___________ Standard Amps required - 1 phase - Water fed @ 40º C __________ 30 Amps - Water fed @ 10º C ___________ 30 Amps Amps required - 3 phase - Water fed @ 40º C __________ 13 Amps - Water fed @ 10º C ___________ 13 Amps Total Connected Load 220-240AC/50/1N _____________ 6.84 kW 380-415AC/50/3N _____________ 6.84 kW Temperature Interlock _____________ Yes Wash tank heating____________ 4.05 kW Rinse boiler heating 220-240AC/50/1N ________________ 6 kW 380-415AC/50/3N ________________ 6 kW Wash pump size ______________ 0.74 kW Wash pump capacity ______ 380 Ltrs/min Wash tank capacity _____________ 39 Ltrs Wash tank operating temperature _____________________ 55˚C Rinse boiler capacity ___________ 7.5 Ltrs Rinse boiler operating temperature _____________________ 80˚C Rinse water consumption - @ 2 Bar _____________________ 3.25 Ltrs
Width________________________ 630 mm Depth________________________ 720 mm Height – hood open_____ 1890-1940 mm Height – hood closed____ 1470-1520 mm Rack size (square) _____________ 500 mm Maximum plates per rack ___________ 18 Maximum clear entry height ___ 385 mm Operating level ________________ <70 db Net weight ____________________ 130 kg Built in air gap ____________________ No (water council approved - WRC) Rinse booster pump __________ Optional Built in detergent dispenser ___ Optional Built in rinse aid dispenser ____ Optional Maximum racks per hour ___________ 40 Cycle Times (mins) _____________ 1½ or 3 Water connection - BSP ___________ 3/4" Water inlet height from floor level ________________ 265-315 mm Required water pressure (flow) ___ 2 bar Required water flow________ 11 Ltrs/min Drain Height from floor level Pump Drain_________________ 0-700 mm Drain size _____________________ 40 mm Drain Pump _________________ Standard Operating voltage - 220-240AC/50/1N _________________ No - 380-415AC/50/3N ___________ Standard Amps required - 3 phase - Water fed @ 40º C __________ 17 Amps - Water fed @ 10º C ___________ 17 Amps Total Connected Load 220-240AC/50/1N __________________ No 380-415AC/50/3N ______________9.48 kW Temperature Interlock _____________ Yes Wash tank heating____________ 4.05 kW Rinse boiler heating 220-240AC/50/1N __________________ No 380-415AC/50/3N _____________ 8.64 kW Wash pump size ______________ 0.74 kW Wash pump capacity ______ 380 Ltrs/min Wash tank capacity _____________ 39 Ltrs Wash tank operating temperature _____________________ 55˚C Rinse boiler capacity ___________ 7.5 Ltrs Rinse boiler operating temperature _____________________ 80˚C Rinse water consumption - @ 2 Bar _____________________ 3.25 Ltrs
Width________________________ 630 mm Depth________________________ 720 mm Height – hood open_____ 1890-1940 mm Height – hood closed____ 1470-1520 mm Rack size (square) _____________ 500 mm Maximum plates per rack ___________ 18 Maximum clear entry height ___ 385 mm Operating level ________________ <70 db Net weight ____________________ 130 kg Built in air gap ____________________ Yes (water council approved - WRC) Rinse booster pump _______________ Yes Built in detergent dispenser ___ Optional Built in rinse aid dispenser ____ Optional Maximum racks per hour ___________ 40 Cycle Times (mins) _____________ 1½ or 3 Water connection - BSP ___________ 3/4" Integrated water softener_____ Optional Water inlet height from floor level ________________ 265-315 mm Required water pressure (flow) ___ 2 bar Required water flow_________ 8 Ltrs/min Drain Height from floor level Pump Drain_________________ 0-700 mm Drain size _____________________ 40 mm Drain Pump _________________ Standard Operating voltage - 220-240AC/50/1N _________________ No - 380-415AC/50/3N ___________ Standard Amps required - 3 phase - Water fed @ 40º C __________ 17 Amps - Water fed @ 10º C ___________ 17 Amps Total Connected Load 220-240AC/50/1N __________________ No 380-415AC/50/3N _____________ 9.48 kW Temperature Interlock _____________ Yes Wash tank heating____________ 4.05 kW Rinse boiler heating 220-240AC/50/1N __________________ No 380-415AC/50/3N _____________ 8.64 kW Wash pump size ______________ 0.74 kW Wash pump capacity ______ 380 Ltrs/min Wash tank capacity _____________ 39 Ltrs Wash tank operating temperature _____________________ 55˚C Rinse boiler capacity ___________ 7.5 Ltrs Rinse boiler operating temperature _____________________ 80˚C Rinse water consumption - @ 2 Bar _____________________ 3.25 Ltrs
Width________________________ 630 mm Depth________________________ 720 mm Height – hood open_____ 1890-1940 mm Height – hood closed____ 1470-1520 mm Rack size (square) _____________ 500 mm Maximum plates per rack ___________ 18 Maximum clear entry height ___ 385 mm Operating level ________________ <70 db Net weight ____________________ 130 kg Built in air gap ____________________ Yes (water council approved - WRC) Rinse booster pump _______________ Yes Built in detergent dispenser ___ Optional Built in rinse aid dispenser ____ Optional Maximum racks per hour ___________ 40 Cycle Times (mins) _____________ 1½ or 3 Water connection - BSP ___________ 3/4" Integrated water softener_____ Optional Water inlet height from floor level ________________ 265-315 mm Required water pressure (flow) ___ 2 bar Required water flow _______ 8.0 Ltrs/min Drain Height from floor level Pump Drain_________________ 0-600 mm Drain size _____________________ 40 mm Drain Pump _________________ Standard Operating voltage - 220-240AC/50/1N _________________ No - 380-415AC/50/3N ___________ Standard Amps required - 3 phase - Water fed @ 40º C __________ 22 Amps - Water fed @ 10º C ___________ 22 Amps Total Connected Load 220-240AC/50/1N __________________ No 380-415AC/50/3N ____________ 12.84 kW Temperature Interlock _____________ Yes Wash tank heating____________ 4.05 kW Rinse boiler heating 220-240AC/50/1N __________________ No 380-415AC/50/3N _______________ 12 kW Wash pump size ______________ 0.74 kW Wash pump capacity ______ 380 Ltrs/min Wash tank capacity _____________ 39 Ltrs Wash tank operating temperature _____________________ 55˚C Rinse boiler capacity ____________ 12 Ltrs Rinse boiler operating temperature _____________________ 80˚C Rinse water consumption - @ 2 Bar _____________________ 3.25 Ltrs
H857A £5045.00 H857A/WS* £5605.00 Complete with WRAS ‘A’ type air gap and drain pump, 3 Phase.
H957 £4910.00 Complete with drain pump, 3 Phase.
£5310.00 H957A H957A/WS* £5875.00 Complete with WRAS ‘A’ type air gap and drain pump, 3 Phase.
H957AS £5650.00 H957AS/WS* £6215.00 Complete with WRAS ‘A’ type air gap and drain pump, 3 Phase.
£5545.00 H957A/DET H957A/WS/DET * £6110.00 Complete with WRAS ‘A’ type air gap, detergent and drain pump, 3 Phase.
£5890.00 H957AS/DET H957AS/WS/DET * £6450.00 Complete with WRAS ‘A’ type air gap, detergent and drain pump, 3 Phase.
* With integral water softener (minimum water pressure of 1.5 bar required) Max water temp 55˚C
* With integral water softener (minimum water pressure of 1.5 bar required) Max water temp 55˚C
H857A DET
£5350.00 £5910.00
H857A/WS/DET* Complete with WRAS ‘A’ type air gap, detergent and drain pump, 3 Phase. H857A/1PH £5045.00 H857A/WS/1PH* £5605.00 Single phase, complete with WRAS ‘A’ type air gap and drain pump.
£5200.00 H957/DET Complete with detergent and drain pump, 3 Phase.
H857A/DET/1PH £5350.00 H857A/WS/DET/1PH* £5910.00 Single phase, complete with WRAS ‘A’ type air gap, detergent and drain pump * With integral water softener (minimum water pressure of 1.5 bar required) Max water temp 55˚C
January 2013
28
Ancillary Tabling and Accessories A range of stainless steel tabling and accessories is available to compliment all Classeq pass through and conveyor ware washers. Fabricated from 304 type food quality stainless steel, all tabling can be manufactured to individual requirements to accommodate special needs such as pipe work etc. Many options are available and Classeq are pleased to offer technical advice where ever needed.
Type
Description Left hand entry table 600mm long Right hand entry table 600mm long Left hand exit table 600mm long Right hand exit table 600mm long
Length(a) x Width(b)
Order Code
Price
600mm x 650mm
T6ENL T6ENR T6EXL T6EXR
£332.00
700mm x 650mm
T7ENL T7ENR T7EXL T7EXR
£332.00
800mm x 650mm
T8ENL T8ENR T8EXL T8EXR
£332.00
1100mm x 650mm
T11ENL T11ENR T11EXL T11EXR
£347.00
1500mm x 650mm
T15ENL T15ENR T15EXL T15EXR
£540.00
Table entry height (c) 875mm (±30mm)
Left hand entry table 700mm long Right hand entry table 700mm long Left hand exit table 700mm long Right hand exit table 700mm long Table entry height (c) 875mm (±30mm)
Left hand entry table 800mm long Right hand entry table 800mm long Left hand exit table 800mm long Right hand exit table 800mm long Table entry height (c) 875mm (±30mm)
Left hand entry table 1100mm long Right hand entry table 1100mm long Left hand exit table 1100mm long Right hand exit table 1100mm long Table entry height (c) 875mm (±30mm)
c
Left hand entry table 1500mm long Right hand entry table 1500mm long Left hand exit table 1500mm long Right hand exit table 1500mm long Table entry height (c) 875mm (±30mm)
29 www.classeq.co.uk
Ancillary Tabling and Accessories A range of stainless steel tabling and accessories is available to compliment all Classeq pass through and conveyor ware washers. Fabricated from 304 type food quality stainless steel, all tabling can be manufactured to individual requirements to accommodate special needs such as pipe work etc. Many options are available and Classeq are pleased to offer technical advice where ever needed.
Model Type
Description
Length(a) x Width(b)
Order Code
Price
Left hand entry table 1100mm long 500 x 400mm sink Single feed overhead prewash spray and mixer taps Full length 400mm high splashback
1100mm x 800mm
T11SENL
£1565.00
Right hand entry table 1100mm long 500 x 400mm sink Single feed overhead prewash spray and mixer taps Full length 400mm high splashback
1100mm x 800mm
T11SENR
£1565.00
Left hand entry table 1500mm long 500 x 400mm sink Single feed overhead prewash spray and mixer taps Full length 400mm high splashback
1500mm x 800mm
T15SENL
£1664.00
Right hand entry table 1500mm long 500 x 400mm sink Single feed overhead prewash spray and mixer taps Full length 400mm high splashback
1500mm x 800mm
T15SENR
£1664.00
Table entry height (c) 875mm (±30mm)
Table entry height (c) 875mm (±30mm)
January 2013
30
Alto Dishwashers Conveyor
A range of 6 models with 27 variants capable of washing between 1800 - 5040 plates per hour. All models come with double skin insulation, autotimers and self draining wash pumps. Heavy duty wash and rinse pumps thoroughout ensure a first class clean and dry result. Space saving corner pre-wash and dryer options are available to maximise the efficiency of the wash up area. Full system design and drawing support is provided by Classeq with CAD drawings and detailed quotations.
Optional extras and accessories. Accessories
Description
Order Code
Heat recovery unit
HRGL
Splashguards for machine
75577/75578
Price
£3780.00 £74.00 £917.00 per pair
Machine split for site access
SPLIT
per split
90˚ Powered exit curve
800mm (w) x 800mm (d) x 875mm (h)
75500
£3955.00
180˚ Powered exit curve
1400mm (w) x 800mm (d) x 875mm (h)
75600
£5840.00
Salt (granulated)
25kg
SALT
£17.00
Baskets
Alto plate Alto cup Alto 8 compartment cutlery
700DRP 700GBP CBP
£36.00 £36.00 £36.00
Water Softener
Automatic - DuoMatik
51-01-206
£1585.00
Dishwashing
Super clean dishwashing detergent 2 x 5l Super clean dishwashing detergent 1 x 20l Super clean dishwashing rinse aid 2 x 5l Super clean dishwashing rinse aid 1 x 20l Dishwashing starter pack - Detergent 2 × 5l - Rinse aid 2 × 5l
DW2-5 DW1-20 DWRA2-5 DWRA1-20
£28.00 £52.00 £23.00 £45.00
SPD
£48.00
Optional integral and rinse aid pump
DET
£612.00
Integral detergent and rinse aid pump
31 www.classeq.co.uk
Alto 100
Alto 100D
Alto 100CD
With power wash zone and rinse zone.
With power wash zone, rinse zone and hot air drying zone.
With power wash zone, rinse zone and corner hot air drying zone.
Specifications
Specifications
Specifications
Length_________________________________________1150 mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour_______________________________100 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 25 Amps - Water fed @ 10º C ______________________ 40 Amps Total Connected Load - Water fed @ 40º C _______________________ 13.3 kW - Water fed @ 10º C _______________________ 22.8 kW Pre wash tank heating ___________________________ Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 14.0 kW - Water fed @ 10º C ________________________ 23.5 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.1kW Wash pump capacity __________________750Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________No Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________240ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________240Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length_________________________________________1750 mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour_______________________________100 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C _______________________32 Amps - Water fed @ 10º C ______________________ 45 Amps Total Connected Load - Water fed @ 40º C _______________________ 19.7 kW - Water fed @ 10º C _______________________ 29.2 kW Pre wash tank heating ___________________________ Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 14.0 kW - Water fed @ 10º C ________________________ 23.5 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.1kW Wash pump capacity __________________750Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________No Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________240ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________240Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length_________________________________________1970 mm Depth ___________________________________880mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour_______________________________100 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 32 Amps - Water fed @ 10º C ______________________ 45 Amps Total Connected Load - Water fed @ 40º C _______________________ 19.7 kW - Water fed @ 10º C _______________________ 29.2 kW Pre wash tank heating ___________________________ Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 14.0 kW - Water fed @ 10º C ________________________ 23.5 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.1kW Wash pump capacity __________________750Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________No Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________240ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________240Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
ALTO 100 Hot fill.
£11725.00
ALTO 100-SEGL £13125.00 Hot fill with extraction spigot. ALTO 100-CVGL Cold fill.
£12070.00
ALTO 100-CVGL-SEGL £13485.00 Cold fill with extraction spigot.
ALTO 100D Hot fill.
£16620.00
ALTO 100D-SEGL £17925.00 Hot fill with extraction spigot. ALTO 100D-CVGL Cold fill.
£16970.00
ALTO 100D-CVGL-SEGL £18270.00 Cold fill with extraction spigot.
ALTO 100CD Hot fill.
£20995.00
ALTO 100CD-SEGL £22260.00 Hot fill with extraction spigot. ALTO 100CD-CVGL Cold fill.
£21315.00
ALTO 100CD-CVGL-SEGL £22610.00 Cold fill with extraction spigot.
January 2013
32
Alto 130
Alto 130D
Alto 130CD
With power wash zone and rinse zone.
With power wash zone, rinse zone and hot air drying zone.
With power wash zone, rinse zone and corner hot air drying zone.
Specifications
Specifications
Specifications
Length_________________________________________1150 mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ___________________________100/130 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 32 Amps - Water fed @ 10º C ______________________ 40 Amps Total Connected Load - Water fed @ 40º C _______________________ 17.5 kW - Water fed @ 10º C _______________________27.0 kW Pre wash tank heating ___________________________ Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 16.0 kW - Water fed @ 10º C ________________________ 25.5 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.1kW Wash pump capacity __________________750Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________No Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________260ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________270Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________1750mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ___________________________100/130 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 23.9 kW - Water fed @ 10º C _______________________33.4 kW Pre wash tank heating ___________________________ Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 16.0 kW - Water fed @ 10º C ________________________ 25.5 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.1kW Wash pump capacity __________________750Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________No Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________260ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________270Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length_________________________________________1970 mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ___________________________100/130 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 23.9 kW - Water fed @ 10º C _______________________33.4 kW Pre wash tank heating ___________________________ Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 16.0 kW - Water fed @ 10º C ________________________ 25.5 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.1kW Wash pump capacity __________________750Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________No Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________260ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________270Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
ALTO 130 Hot fill.
£13205.00
ALTO 130-SEGL £14595.00 Hot fill with extraction spigot. ALTO 130-CVGL Cold fill.
£13565.00
ALTO 130-CVGL-SEGL £14930.00 Cold fill with extraction spigot.
33 www.classeq.co.uk
ALTO 130D Hot fill.
£18405.00
ALTO 130D-SEGL £19325.00 Hot fill with extraction spigot. ALTO 130D-CVGL Cold fill.
£18765.00
ALTO 130D-CVGL-SEGL £19655.00 Cold fill with extraction spigot.
ALTO 130CD Hot fill.
£22605.00
ALTO 130CD-SEGL £23525.00 Hot fill with extraction spigot. ALTO 130CD-CVGL Cold fill.
£23045.00
ALTO 130CD-CVGL-SEGL £23855.00 Cold fill with extraction spigot.
Alto 170
Alto 170D
Alto 170CD
With power pre wash zone, power wash zone and rinse zone.
With power pre wash zone, power wash zone, rinse zone and hot air drying zone.
With power pre wash zone, power wash zone, rinse zone and corner hot air drying zone.
Specifications
Specifications
Specifications
Length_________________________________________1970 mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ___________________________130/170 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 32 Amps - Water fed @ 10º C ______________________ 50 Amps Total Connected Load - Water fed @ 40º C _______________________ 21.2 kW - Water fed @ 10º C _______________________ 30.7 kW Pre wash tank heating ___________________________ Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 19.0 kW - Water fed @ 10º C ________________________ 28.5 kW Pre wash pump size________________________0.8Kw Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________1.1kW Wash pump capacity __________________750Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________No Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________320ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/5/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________320Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length_________________________________________2570 mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ___________________________130/170 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 27.6 kW - Water fed @ 10º C _______________________ 37.1 kW Pre wash tank heating ___________________________ Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 19.0 kW - Water fed @ 10º C ________________________ 28.5 kW Pre wash pump size________________________0.8Kw Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________1.1kW Wash pump capacity __________________750Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________No Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________320ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/5/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________320Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length_________________________________________2790 mm Depth ___________________________________880mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ___________________________130/170 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 27.6 kW - Water fed @ 10º C _______________________ 37.1 kW Pre wash tank heating ___________________________ Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 19.0 kW - Water fed @ 10º C ________________________ 28.5 kW Pre wash pump size________________________0.8Kw Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________1.1kW Wash pump capacity __________________750Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________No Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________320ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/5/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________320Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
ALTO 170 Hot fill.
£19015.00
ALTO 170-SEGL £20325.00 Hot fill with extraction spigot. ALTO 170-CVGL Cold fill.
£19365.00
ALTO 170-CVGL-SEGL £20665.00 Cold fill with extraction spigot.
ALTO 170D Hot fill.
£23895.00
ALTO 170D-SEGL £25210.00 Hot fill with extraction spigot. ALTO 170D-CVGL Cold fill.
£24265.00
ALTO 170D-CVGL-SEGL £25555.00 Cold fill with extraction spigot.
ALTO 170CD Hot fill.
£28260.00
ALTO 170CD-SEGL £29565.00 Hot fill with extraction spigot. ALTO 170CD-CVGL Cold fill.
£29910.00
ALTO 170CD-CVGL-SEGL £29910.00 Cold fill with extraction spigot.
January 2013
34
Alto 170CP
Alto 170CPD
Alto 170CPCD
With corner power pre wash zone, power wash zone and rinse zone.
With corner power pre wash zone, power wash zone, rinse zone and hot air drying zone.
With corner power pre wash zone, power wash zone, rinse zone and corner hot air drying zone.
Specifications
Specifications
Specifications
Length_________________________________________1970 mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________65/130/170 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 32 Amps - Water fed @ 10º C ______________________ 50 Amps Total Connected Load - Water fed @ 40º C _______________________ 21.2 kW - Water fed @ 10º C _______________________ 30.7kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 10.5 kW - Water fed @ 10º C ________________________ 20.0 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________170ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Steam Condenser unit ___________________Optional Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________2570mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________65/130/170 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 27.6 kW - Water fed @ 10º C _______________________ 37.1 kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 10.5 kW - Water fed @ 10º C ________________________ 20.0 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________170ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Steam Condenser unit ___________________Optional Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________2570mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________65/130/170 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 27.6 kW - Water fed @ 10º C _______________________ 37.1 kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 10.5 kW - Water fed @ 10º C ________________________ 20.0 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________170ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Steam Condenser unit ___________________Optional Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
ALTO 170CP Hot fill.
£21600.00
ALTO 170CP-SEGL £22895.00 Hot fill with extraction spigot. ALTO 170CP-CVGL Cold fill.
£21945.00
ALTO 170CP-CVGL-SEGL £23250.00 Cold fill with extraction spigot.
35 www.classeq.co.uk
ALTO 170CPD Hot fill.
£26490.00
ALTO 170CPD-SEGL £27785.00 Hot fill with extraction spigot. ALTO 170CPD-CVGL Cold fill.
£26832.00
ALTO 170CPD-CVGL-SEGL £28135.00 Cold fill with extraction spigot.
ALTO 170CPCD Hot fill.
£30835.00
ALTO 170CPCD-SEGL £32130.00 Hot fill with extraction spigot. ALTO 170CPCD-CVGL Cold fill.
£31180.00
ALTO 170CPCD-CVGL-SEGL £32475.00 Cold fill with extraction spigot.
Alto 170X
Alto 170XD
Alto 170XCD
With power wash zone and 4 stage eco rinse.
With power wash zone, 4 stage eco rinse and hot air drying zone.
With power wash zone, 4 stage eco rinse and corner hot air drying zone.
Specifications
Specifications
Specifications
Length_________________________________________1550 mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________65/130/170 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 32 Amps - Water fed @ 10º C ______________________ 45 Amps Total Connected Load - Water fed @ 40º C _______________________ 20.5 kW - Water fed @ 10º C _______________________ 30.0 kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 10.5 kW - Water fed @ 10º C ________________________ 20.0 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________170ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length_________________________________________2150 mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________65/130/170 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 26.9 kW - Water fed @ 10º C _______________________ 36.4 kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 10.5 kW - Water fed @ 10º C ________________________ 20.0 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________170ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length_________________________________________2370 mm Depth ___________________________________880mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<64 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________65/130/170 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 26.9 kW - Water fed @ 10º C _______________________ 36.4 kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 10.5 kW - Water fed @ 10º C ________________________ 20.0 kW Pre wash pump size _____________________________ Pre wash pump capacity _________________________ Pre wash tank capacity __________________________ Pre wash tank operating temperature_____________ Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________170ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
ALTO 170X Hot fill.
£18235.00
ALTO 170X-SEGL £19540.00 Hot fill with extraction spigot. ALTO 170X-CVGL Cold fill.
£18585.00
ALTO 170X-CVGL-SEGL £19880.00 Cold fill with extraction spigot.
ALTO 170XD Hot fill.
£23130.00
ALTO 170XD-SEGL £24440.00 Hot fill with extraction spigot. ALTO 170XD-CVGL Cold fill.
£23485.00
ALTO 170XD-CVGL-SEGL £24780.00 Cold fill with extraction spigot.
£26235.00
ALTO 170XCD Hot fill.
ALTO 170XCD-SEGL £27535.00 Hot fill with extraction spigot. ALTO 170XCD-CVGL Cold fill.
£26585.00
ALTO 170XCD-CVGL-SEGL £27885.00 Cold fill with extraction spigot.
January 2013
36
Alto 220
Alto 220D
Alto 220CD
With power pre wash zone, power wash zone and 4 stage eco rinse.
With power pre wash zone, power wash zone, 4 stage eco rinse and hot air drying zone.
With power pre wash zone, power wash zone, 4 stage eco rinse and corner hot air drying zone.
Specifications
Specifications
Specifications
Length _________________________________________2370mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________80/160/220 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 50 Amps Total Connected Load - Water fed @ 40º C _______________________ 25.3kW - Water fed @ 10º C _______________________ 34.8 kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 14.0 kW - Water fed @ 10º C ________________________ 23.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________220ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________2970mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________80/160/220 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 45 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 31.7kW - Water fed @ 10º C _______________________ 41.2 kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 14.0 kW - Water fed @ 10º C ________________________ 23.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________220ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________3190mm Depth ___________________________________880mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________80/160/220 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 45 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 31.7kW - Water fed @ 10º C _______________________ 41.2 kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 14.0 kW - Water fed @ 10º C ________________________ 23.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________220ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
ALTO 220 Hot fill.
£24685.00
ALTO 220-SEGL £25995.00 Hot fill with extraction spigot. ALTO 220-CVGL Cold fill.
£25035.00
ALTO 220-CVGL-SEGL £26340.00 Cold fill with extraction spigot.
37 www.classeq.co.uk
ALTO 220D Hot fill.
£29435.00
ALTO 220D-SEGL £30730.00 Hot fill with extraction spigot. ALTO 220D-CVGL Cold fill.
£29780.00
ALTO 220D-CVGL-SEGL £31080.00 Cold fill with extraction spigot.
ALTO 220CD Hot fill.
£33935.00
ALTO 220CD-SEGL £35235.00 Hot fill with extraction spigot. ALTO 220CD-CVGL Cold fill.
£34280.00
ALTO 220CD-CVGL-SEGL £35580.00 Cold fill with extraction spigot.
Alto 220CP
Alto 220CPD
Alto 220CPCD
With corner power pre wash zone, power wash zone and 4 stage eco rinse.
With corner power pre wash zone, power wash zone, 4 stage eco rinse and hot air drying zone.
With corner power pre wash zone, power wash zone, 4 stage eco rinse and corner hot air drying zone.
Specifications
Specifications
Specifications
Length _________________________________________2370mm Depth ___________________________________990mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________80/160/220 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 40 Amps - Water fed @ 10º C ______________________ 50 Amps Total Connected Load - Water fed @ 40º C _______________________ 25.3kW - Water fed @ 10º C _______________________ 34.8kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 14.0 kW - Water fed @ 10º C ________________________ 23.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________220ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________2970mm Depth ___________________________________990mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________80/160/220 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 45 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 31.7kW - Water fed @ 10º C _______________________ 41.2kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 14.0kW - Water fed @ 10º C ________________________ 23.5kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________220ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________3190mm Depth ___________________________________990mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour ________________________80/160/220 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 45 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 31.7kW - Water fed @ 10º C _______________________ 41.2kW Pre wash tank heating_______________________8kW Wash tank heating ________________________8.0kW Rinse boiler heating - Water fed @ 40º C ________________________ 14.0 kW - Water fed @ 10º C ________________________ 23.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________1.4kW Wash pump capacity __________________800Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________220ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
ALTO 220CP Hot fill.
£27260.00
ALTO 220CP-SEGL £28570.00 Hot fill with extraction spigot. ALTO 220CP-CVGL Cold fill.
£27615.00
ALTO 220CP-CVGL-SEGL £28920.00 Cold fill with extraction spigot.
ALTO 220CPD Hot fill.
£32115.00
ALTO 220CPD-SEGL £33415.00 Hot fill with extraction spigot. ALTO 220CPD-CVGL Cold fill.
£32475.00
ALTO 220CPD-CVGL-SEGL £33765.00 Cold fill with extraction spigot.
£36465.00
ALTO 220CPCD Hot fill.
ALTO 220CPCD-SEGL £37770.00 Hot fill with extraction spigot. ALTO 220CPCD-CVGL Cold fill.
£36820.00
ALTO 220CPCD-CVGL-SEGL £38115.00 Cold fill with extraction spigot.
January 2013
38
Alto 280
Alto 280D
Alto 280CD
With power pre wash zone, power wash zone and 4 stage eco rinse.
With power pre wash zone, power wash zone, 4 stage eco rinse and hot air drying zone.
With power pre wash zone, power wash zone, 4 stage eco rinse and corner hot air drying zone.
Specifications
Specifications
Specifications
Length _________________________________________2370mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour _______________________105/210/280 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 50 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 31.8kW - Water fed @ 10º C _______________________ 41.3kW Pre wash tank heating_______________________8kW Wash tank heating ________________________9.5kW Rinse boiler heating - Water fed @ 40º C ________________________ 19.0 kW - Water fed @ 10º C ________________________ 28.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________2.0kW Wash pump capacity __________________900Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________280ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Steam Condenser unit ___________________Optional Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________2970mm Depth ___________________________________770mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour _______________________105/210/280 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 63 Amps - Water fed @ 10º C ______________________ 80 Amps Total Connected Load - Water fed @ 40º C _______________________ 38.2kW - Water fed @ 10º C _______________________ 47.7kW Pre wash tank heating_______________________8kW Wash tank heating ________________________9.5kW Rinse boiler heating - Water fed @ 40º C ________________________ 19.0 kW - Water fed @ 10º C ________________________ 28.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________2.0kW Wash pump capacity __________________900Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________280ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Steam Condenser unit ___________________Optional Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________3190mm Depth ___________________________________880mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour _______________________105/210/280 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 63 Amps - Water fed @ 10º C ______________________ 80 Amps Total Connected Load - Water fed @ 40º C _______________________ 38.2kW - Water fed @ 10º C _______________________ 47.7kW Pre wash tank heating_______________________8kW Wash tank heating ________________________9.5kW Rinse boiler heating - Water fed @ 40º C ________________________ 19.0 kW - Water fed @ 10º C ________________________ 28.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________2.0kW Wash pump capacity __________________900Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________280ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Steam Condenser unit ___________________Optional Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
ALTO 280 Hot fill.
£26775.00
ALTO 280-SEGL £28080.00 Hot fill with extraction spigot. ALTO 280-CVGL Cold fill.
£27125.00
ALTO 280-CVGL-SEGL £28430.00 Cold fill with extraction spigot.
39 www.classeq.co.uk
ALTO 280D Hot fill.
£31650.00
ALTO 280D-SEGL £32950.00 Hot fill with extraction spigot. ALTO 280D-CVGL Cold fill.
£31995.00
ALTO 280D-CVGL-SEGL £33295.00 Cold fill with extraction spigot.
ALTO 280CD Hot fill.
£36025.00
ALTO 280CD-SEGL £37325.00 Hot fill with extraction spigot. ALTO 280CD-CVGL Cold fill.
£36375.00
ALTO 280CD-CVGL-SEGL £38310.00 Cold fill with extraction spigot.
Alto 280CP
Alto 280CPD
Alto 280CPCD
With corner power pre wash zone, power wash zone and 4 stage eco rinse.
With corner power pre wash zone, power wash zone, 4 stage eco rinse and hot air drying zone.
With corner power pre wash zone, power wash zone, 4 stage eco rinse and corner hot air drying zone.
Specifications
Specifications
Specifications
Length _________________________________________2370mm Depth ___________________________________990mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour _______________________105/210/280 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 50 Amps - Water fed @ 10º C ______________________ 63 Amps Total Connected Load - Water fed @ 40º C _______________________ 31.8kW - Water fed @ 10º C _______________________ 41.3kW Pre wash tank heating_______________________8kW Wash tank heating ________________________9.5kW Rinse boiler heating - Water fed @ 40º C ________________________ 19.0 kW - Water fed @ 10º C ________________________ 28.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________2.0kW Wash pump capacity __________________900Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________280ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Steam Condenser unit ___________________Optional Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________2970mm Depth ___________________________________990mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour _______________________105/210/280 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 63 Amps - Water fed @ 10º C ______________________ 80 Amps Total Connected Load - Water fed @ 40º C _______________________ 38.2kW - Water fed @ 10º C _______________________ 47.7kW Pre wash tank heating_______________________8kW Wash tank heating ________________________9.5kW Rinse boiler heating - Water fed @ 40º C ________________________ 19.0 kW - Water fed @ 10º C ________________________ 28.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________2.0kW Wash pump capacity __________________900Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________280ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Steam Condenser unit ___________________Optional Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
Length _________________________________________3190mm Depth ___________________________________990mm Height _________________________________1565mm Height - door open ______________________2025mm Rack size ________________________________500mm No of plates per rack __________________________18 Useable wash chamber height _____________400mm Operating noise level______________________<66 db Weight _________________________________________ Built in air gap (WRAS approved)_________Standard Rinse Booster Pump _____________________Standard Built in detergent dispenser______________Optional Built in rinse aid dispenser _______________Optional Double skinned cabinet _________________Standard Autotimer______________________________Standard Racks per hour _______________________105/210/280 Water connection - BSP ______________________3/4" Water inlet height from floor level_________226mm Required water pressure ________________1 to 3 bar Required water flow ___________________15ltrs/min Maximum Drain Height from floor level ____171mm Drain size __________________________________11/2” Amps required - 3 Phase - Water fed @ 40º C ______________________ 63 Amps - Water fed @ 10º C ______________________ 80 Amps Total Connected Load - Water fed @ 40º C _______________________ 38.2kW - Water fed @ 10º C _______________________ 47.7kW Pre wash tank heating_______________________8kW Wash tank heating ________________________9.5kW Rinse boiler heating - Water fed @ 40º C ________________________ 19.0 kW - Water fed @ 10º C ________________________ 28.5 kW Pre wash pump size _______________________0.8kW Pre wash pump capacity_______________400Ltrs/min Pre wash tank capacity _____________________45Ltrs Pre wash tank operating temperature ________45°C Wash pump size ___________________________2.0kW Wash pump capacity __________________900Ltrs/min Wash tank capacity ________________________70Ltrs Wash tank operating temperature____________55°C 4 Stage eco rinse _____________________________Yes Rinse boiler capacity _______________________17Ltrs Rinse boiler operating temperature __________85°C Rinse water consumption_______________280ltrs/hrs Drying tunnel___________________________Optional Corner Drying Tunnel____________________Optional Drying tunnel length _____________________600mm Drying tunnel loading _____________________6.4kW Drying tunnel circulation ______________1150m/3/hr Drying tunnel relative humidity ______________25% Heat recovery unit ______________________Optional Circulation ____________________________700m/3/hr Reduction in electrical loading______________5.0kW Steam Condenser unit ___________________Optional Cold Water Consumption _______________250Ltrs/hr Circulation ____________________________700m/3/hr Extraction Spigot _______________________Optional Diameter_______________________________250Ømm Integral Extraction Fan __________________Optional Diameter_______________________________250Ømm Circulation ____________________________700m/3/hr
ALTO 280CP Hot fill.
£29355.00
ALTO 280CP-SEGL £30650.00 Hot fill with extraction spigot. ALTO 280CP-CVGL Cold fill.
£29705.00
ALTO 280CP-CVGL-SEGL £31005.00 Cold fill with extraction spigot.
ALTO 280CPD Hot fill.
£34205.00
ALTO 280CPD-SEGL £35510.00 Hot fill with extraction spigot. ALTO 280CPD-CVGL Cold fill.
£34555.00
ALTO 280CPD-CVGL-SEGL £35850.00 Cold fill with extraction spigot.
£38630.00
ALTO 280CPCD Hot fill.
ALTO 280CPCD-SEGL £39925.00 Hot fill with extraction spigot. ALTO 280CPCD-CVGL Cold fill.
£38970.00
ALTO 280CPCD-CVGL-SEGL £40275.00 Cold fill with extraction spigot.
January 2013
40
Viso Utensil Washers The 5 models in the Viso range are designed to wash all manner and sizes of pots and kitchen utensils as well as bakery trays and tote boxes. With rack sizes from a standard 500mm width to 1320mm wide and extra powerful self draining wash pumps these machines can remove the most stubborn of soiling. Double skin insulation, cantilevered opening doors and a choice of wash cycles make the entire range safe, simple and easy to use.
Optional extras and accessories. Accessories
Description
Order Code
Water softener
Automatic Automatic hot water
WSAUTO WSHC10
Dishwashing
Super clean dishwashing detergent 2 x 5l Super clean dishwashing detergent 1 x 20l Super clean dishwashing rinse aid 2 x 5l Super clean dishwashing rinse aid 1 x 20l
DW2-5 DW1-20 DWRA2-5 DWRA1-20
Racks
5 division stainless steel rack (max tray depth 65mm) 8 division stainless steel rack (max tray depth 40mm)
7120185 H-324660
41 www.classeq.co.uk
Price
£695.00 £930.00
£28.00 £52.00 £23.00 £45.00 £188.00 £161.00
V50
Specifications
V55/55H*
V70
V132
Specifications
Specifications
Specifications
Width________________________ 667 mm
Width _______________________ 720 mm
Width________________________ 850 mm
Width ______________________ 1465 mm
Depth________________________ 716 mm
Depth _______________________ 780 mm
Depth _______________________ 850 mm
Depth _______________________ 850 mm
Depth - Door open __________ 1191 mm
Depth - Door open __________ 1180 mm
Depth - Door open __________ 1250 mm
Depth - Door open ___________ 1250 mm
Height ________________ 1473 +/-30 mm
Height _________________ 1730 +/-30 mm
Height ________________ 1730 +/-30 mm
Height ________________ 1730 +/-30 mm
Height - Door open _____ 1473 +/-30 mm
Height - Door open 2000/2200* +/-30 mm
Height - Door open_____ 2000 +/-30 mm
Height - Door open _____ 2000 +/-30 mm
Rack Width __________________ 500 mm
Rack Width __________________ 550 mm
Rack Width __________________ 700 mm
Rack Width _________________ 1320 mm
Rack Depth __________________ 600 mm
Rack Depth __________________ 610 mm
Rack Depth __________________ 700 mm
Rack Depth __________________ 700 mm
Useable wash chamber height __400 mm
Useable wash chamber height 650/850* mm
Useable wash chamber height _ 650 mm
Useable wash chamber height _ 650 mm
Operating noise level ____________ 68 dB
Operating noise level ____________ 68 dB
Operating noise level ___________ 68 dB
Operating noise level ____________ 69 dB
Weight - Net __________________ 120 kg
Weight - Net __________________ 155 kg
Weight - Net __________________ 190 kg
Weight - Net __________________ 295 kg
Built in air gap ____________________ yes
Built in air gap ____________________ yes
Built in air gap ____________________ yes
Built in air gap ____________________ yes
Rinse Booster Pump __________ standard
Rinse Booster Pump __________ standard
Rinse Booster Pump __________ standard
Rinse Booster Pump __________ standard
Built in detergent dispenser _____ option
Built in detergent dispenser _____ option
Built in detergent dispenser _____ option
Built in detergent dispenser _____ option
Built in rinse aid dispenser ______ option
Built in rinse aid dispenser ______ option
Built in rinse aid dispenser ______ option
Built in rinse aid dispenser ______ option
Double skinned cabinet ____________ yes
Double skinned cabinet ____________ yes
Double skinned cabinet ____________ yes
Double skinned cabinet ____________ yes
Racks per hour (maximum) _________ 30
Racks per hour (maximum) _________ 30
Racks per hour (maximum) _________ 30
Racks per hour (maximum) _________ 30
Water connection - BSP _____________ 3⁄4”
Water connection - BSP _____________ 3⁄4”
Water connection - BSP ____________ 3⁄4”
Water connection - BSP ____________ 3⁄4”
Water inlet height from floor level _______________ 198 +/-30 mm
Water inlet height from floor level ________________ 165-225 mm
Water inlet height from floor level ________________ 165-225 mm
Water inlet height from floor level ________________ 165-225 mm
(solenoid valve height)
(solenoid valve height)
(solenoid valve height)
(solenoid valve height)
Required water pressure _____ 1 to 4 bar
Required water pressure _____ 1 to 4 bar
Required water pressure _____ 1 to 4 bar
Required water pressure _____ 1 to 4 bar
Required water flow _______________ n/a
Required water flow _______________ n/a
Required water flow _______________ n/a
Required water flow ______________ n/a
(inlet solenoid valve capacity at 3 bar)
(inlet solenoid valve capacity at 3 bar)
(inlet solenoid valve capacity at 3 bar)
(inlet solenoid valve capacity at 3 bar)
Maximum Drain Height from floor level __________ 390 +/-30 mm
Maximum Drain Height from floor level _________ 300 +/-30 mm
Maximum Drain Height from floor level _________ 235 +/-30 mm
Maximum Drain Height from floor level _________ 235 +/-30 mm Drain size _____________________ 50 mm
Drain size _____________________ 50 mm
Drain size _____________________ 50 mm
Drain size _____________________ 50 mm
Amps required - 3 Phase
Amps required - 3 Phase
Amps required - 3 Phase
Amps required - 3 Phase
- Water fed @ 40º C ___________ 16 Amps
- Water fed @ 40º C ___________ 16 Amps
- Water fed @ 40º C ___________ 20 Amps
- Water fed @ 40º C ___________ 25 Amps
- Water fed @ 10º C ________________ n/a
- Water fed @ 10º C ___________ 16 Amps
- Water fed @ 10º C ___________ 20 Amps
- Water fed @ 10º C ___________ 25 Amps
Total Connected Load
Total Connected Load
Total Connected Load
Total Connected Load
- Water fed @ 40º C _____________ 7.1 kW
- Water fed @ 40º C ________ 7.4/8.0* kW
- Water fed @ 40º C _____________ 11 kW
- Water fed @ 40º C ____________ 15.5 kW
- Water fed @ 10º C _________________ n/a
- Water fed @ 10º C _________ 7.4/8.0* kW
- Water fed @ 10º C _____________ 11 kW
- Water fed @ 10º C ____________ 15.5 kW
Wash tank heating _____________ 3.0 kW
Wash tank heating ____________ 3.0 kW
Wash tank heating ____________ 6.0 kW
Wash tank heating _____________ 8.0 kW
Rinse boiler heating
Rinse boiler heating
Rinse boiler heating
Rinse boiler heating
- Water fed @ 40º C _____________ 6.0 kW
- Water fed @ 40º C _____________ 6.0 kW
- Water fed @ 40º C _____________ 8.0 kW
- Water fed @ 40º C _____________ 9.5 kW
- Water fed @ 10º C ________________ n/a
- Water fed @ 10º C _____________ 6.0 kW
- Water fed @ 10º C _____________ 8.0 kW
- Water fed @ 10º C _____________ 9.5 kW
Wash pump size ______________ 1.1 kW
Wash pump size _______________ 1.4 kW
Wash pump size ________________ 3 kW
Wash pump size _______________ 2x3kW
Wash pump capacity ______ 485 Ltrs/min
Wash pump capacity ______ 650 Ltrs/min
Wash pump capacity _____ 1200 Ltrs/min
Wash pump capacity ___ 2x1200 Ltrs/min
Wash tank capacity ____________ 20 Ltrs
Wash tank capacity ____________ 45 Ltrs
Wash tank capacity ____________ 60 Ltrs
Wash tank capacity ___________ 115 Ltrs
Wash tank operating temperature ____________________ 55 ˚C
Wash tank operating temperature ____________________ 55 ˚C
Wash tank operating temperature ____________________ 55 ˚C
Wash tank operating temperature ____________________ 55 ˚C
Rinse boiler capacity ___________ 12 Ltrs
Rinse boiler capacity ____________ 14 Ltrs
Rinse boiler capacity ___________ 14 Ltrs
Rinse boiler capacity ___________ 14 Ltrs
Rinse boiler operating temperature ____________________ 85 ˚C
Rinse boiler operating temperature ____________________ 85 ˚C
Rinse boiler operating temperature ____________________ 85 ˚C
Rinse boiler operating temperature ____________________ 85 ˚C
Rinse water consumption ________ 3 Ltrs
Rinse water consumption ________ 4 Ltrs
Rinse water consumption ________ 5 Ltrs
Rinse water consumption ________ 8 Ltrs
Extraction Spigot __________________ n/a
Extraction Spigot __________________ n/a
Extraction Spigot __________________ yes
Extraction Spigot _________________ yes
Diameter
Diameter _____________________ 120 mm
Diameter _____________________ 180 mm
£10700.00 VISO 70 VISO 70 DET £11095.00 Integral detergent and rinse aid dispenser
VISO 132 £18235.00 VISO 132 DET £18715.00 Integral detergent and rinse aid dispenser
Diameter
*Relates to the Viso 55H model
VISO 50 £5470.00 VISO 50 DET £5760.00 Integral detergent and rinse aid dispenser
VISO 55 £6645.00 VISO 55 DET £7120.00 Integral detergent and rinse aid dispenser VISO 55H £7430.00 VISO 55H DET £7880.00 Integral detergent and rinse aid dispenser
January 2013
42
Detergents and Hygiene Products As part of the Winterhalter group Classeq is able to supply the Hygiene Express range of professional catering hygiene products. Further details of the entire range of cleaning products and consumables are available from your Classeq area sales manager.
Product Application
Product Name
Quantity
Order Code
Glasswashing Products
Super clean glasswashing detergent G3 glass rejuvenator Super shine glasswashing rinse aid Glasswasher starter pack glasswash detergent Glasswasher starter pack rinse aid Super clean dishwashing detergent Super clean dishwashing detergent Super shine dishwashing rinse aid Super shine dishwashing rinse aid Dishwashing starter pack detergent Dishwashing starter pack dishwashing rinse aid Super descaler
2 × 5l 1 × 10kg 2 × 5l 2 × 5l 2 × 5l 2 × 5l 1 × 20l 2 × 5l 1 × 20l 2 × 5l 2 × 5l 2 × 5l
GW2-5 G3/10 GWRA2-5
£28.00 £71.00 £23.00
SPG DW2-5 DW1-20 DWRA2-5 DWRA1-20
£48.00 £28.00 £52.00 £23.00 £45.00
SPD DE 2-5
£48.00 £28.00
Dishwashing Products
43 www.classeq.co.uk
Price
Service and Maintenance Contracts Enjoy complete peace of mind with Classeq’s range of tailored service contracts. We will be happy to discuss your requirements and provide a proposal which will cater for all your warewashing service needs. Four star ****
Break down cover only. Call out and labour included. All replacements parts, will be charged.
Five star *****
Breakdown cover with call out, labour and parts included.
Machine category
Machine type
Four star ****
Five star *****
Undercounter Glasswashers Undercounter Dishwashers Pass through Dishwashers Utensil washers Dishwashers Rack conveyor Dishwashers
Eco & Duo models
£215
£337
Hydro & Duo models
£215
£337
Hydro 850/950
£236
£618
Viso 50/55/55H/70 Viso 132 Alto 100/130/170/170X Alto 220/280
£356 £356 £356 £356
£768 £927 £768 £1200
Service and Maintenance Contracts Time and material charges: Service labour charges (Time and materials charges for non-contract customers)
Call out
Labour p/hour p/hour
£77.00
£59.00
London Call out
London Labour p/hour p/hour
£83.00
£67.00
Eau de Vie Service and Maintenance Contract Five star *****
Includes all breakdowns, call out, parts, labour and 2 filter changes
£670 per year
Filter Change only contract
Includes 1 filter change and cleaning/sanitization of water system, does not include any additional parts and additional breakdowns will be charged
£284 per year
Machine Warranties Machine category
Cost Per Year
Undercounter Glasswashers and Dishwashers £235 Ice Machines £235 Pass through Dishwashers £353 Utensils and automatic Rack Price on application Note: Extended warranties must be purchased at the time machine is ordered. Normal working hours (0800-1700 Mon-Fri) January 2013
44
Your Local Distributor