Preview only show first 10 pages with watermark. For full document please download

Price List Microscopy

   EMBED


Share

Transcript

Price List Microscopy ƒ ƒ ƒ ƒ ƒ Upright Microscopes Inverted Microscopes Incident Light and Workshop Microscopes Stereomicroscopes Digital Cameras Issue July 2011 Quality „Made in Germany“ Your contact partners: Distributor support Werner Kampe Sales and Marketing Manager Phone: +49 (06441) 2004-60 e-mail: [email protected] Customer & quotation service national, order processing Petra Hertstein-Hecker Sales Assistant Phone: +49 (06441) 2004-26 e-mail: [email protected] Service, spare parts and repairs Michael Wagner Head of service department and technical support Phone: +49 (06441) 2004-51 e-mail: [email protected] Customer & quotation service international, order processing Susanne Bartel Sales Assistant Phone: +49 (06441) 2004-24 e-mail: [email protected] Technical & application advice Dr. Jörg Haus Product Manager Phone: +49 (06441) 2004-28 e-mail: [email protected] Helmut Hund GmbH Wilhelm-Will-Strasse 7 D-35580 Wetzlar Fax 06441 2004-44 Tel. 06441 2004-0 E-Mail: [email protected] Internet: www.hund.de Important Information for our business partners and customers This pricelist supersedes all previous versions. Our general terms and conditions are applicable. They are available for download at our website www.hund.de. Terms of delivery to destinations outside Germany are ex factory Wetzlar. Information regarding Medical Device Law and Certifications Microscopes are so-called In-vitro-diagnostic instruments according to the Medical Device Law (MPG § 3 / 4) if they are used for the investigation of specimen derived from the human body. Products must be used in compliance with the purpose of the device as it is defined by the manufacturer. According to the Medical Device Operator Ordinance (MPBetreibV § 2 / 5) the user has to assure himself - before setting the medical device in use - of the functionality and the proper condition of the medical device. In addition, the user has to read the operating instructions and has to follow the attached security and maintenance advices as well. The configuration delivered contains means which enable the user to adjust the microscope properly (according to Köhler) and to adjust special configurations such as phase contrast and darkfield in a proper way. The user is therefore in a position to prove the proper condition of his Hund-microscope in case adequate certifications of his laboratory will be carried out. Tests • • • • Protective conductor test acc. to EN-61010, Test current 25 A, Threshold 0,1 Ohm High voltage test acc. to EN-61010, Test voltage 1350 V AC Leakage current test acc. to EN-61010, Measurement set-up A2 Test voltage 230 V AC, Threshold 0,7 mA with 2 kOhm EG-Declaration of Conformity - CE-mark The instrument matches the EG-Directive 98/79/EWG-IVD, the directive 73/23/EWG - low voltage directive - and the directive 89/336/EWG concerning the electromagnetic compatibility. We are certified according to DIN EN ISO 9001:2000 (quality management) and DIN EN ISO 14 001 (environmental management) and are validated according to EG-Regulation 761/2001 (Öko-Audit). Warranty The warranty on microscopes as well as on optical and mechanical components is 2 years after transfer of perils and 1 year for cameras and other electronic products. Lamps, fuses and consumables are not included in the warranty. During these 2 years warranty damages will be handled free of charge in our factory in Wetzlar. This warranty does not cover damages caused through outside influences or inappropriate handling. The freight charges have to be borne by both parties. Each party will bear 50 % of the freight and handling charges. Furthermore we offer for a period up to 20 years professional repairs and supply of spare parts for mechanical and optical components. Availability needs to be clarified per individual case. Claims should be reported immediately and in written form not later than 8 days after receipt of the goods. Maintenance and repairs Servicing and repairs will be carried out for microscopes of the brands Hund or Will only. Spare parts and transportation cost will be charged separately. Repair cost will be charged according to the actual working hours occurring for the individual repair. Our quotations on repairs are not binding, since hidden damages can only be detected during the process of maintenance and repair. We will charge a diagnostic lump sum of EUR 50,00 for checking the instrument and for calculating the precise repair costs. These costs for a diagnosis will not be charged in case of a repair order. For the maintenance and repair of larger numbers of microscopes (for example in schools or universities) we provide the possibility of an on-site inspection. For the repair of single units of microscopes, we recommend to carry out the repair work in our factory to optimise cost. Our repair and service invoices are quoted plus V.A.T. (according to the current rates) and are payable without cash discount. The warranty period for claims of damages on repairs is 6 months counting from transfer of perils. In the case of a repair no new warranty period for claims of damages is starting. Starting date is the purchase of the customer and the assignment of the repair. Microscopes are optical precision instruments. In case of return to our premises for maintenance or repair it is recommended to utilise the original or an equivalent packaging. Upright microscopes Product page Overview on the microscope stand configurations 4 Microscopes for education 6 Microscopes for medical practitioners - haematology 7 Microscopes for medical practitioners and hospitals - haematology - urology 8 Microscopes for central laboratories and hospitals - haematology - urology - gynaecology - dermatology 9 Configurations for pathology 10 Configurations for bacteriology 11 Equipment for immunology 13 Filtersets for H 600 AFL 13 Microscopes for heating stage - native specimen - fertility investigations 14 Fluorescence microscopes with LED-illumination 15 Configurations for investigations of native blood in darkfield 17 Equipment for investigation of microorganisms in liquids - breweries - sewage treatment plants 17 Polarising microscopes 18 Polarising microscopy - components 19 Components for upgrading of upright microscopes - objectives - condensers and accessories - eyepieces - pointing, measuring and counting with graticules - tubes - discussion tube - trinocular tubes - adaptation of video and photo accessories - LED-fluorescence-illuminators - attachable mirrors - immersion oil and cleaning liquids - specimen holder - storage and transportation - heating stages - accessory sets - halogen lamps, spare bulbs, mercury high pressure lamps 20 22 22 23 24 24 24 24 24 25 25 25 25 25 25 27 Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 1 Inverted microscopes Product page Overview on the microscope stand configurations 30 Inverted microscopes for botany, cell culture laboratories, cell biology / fluorescence - plancton - dreissena-larvae - rotatories/ciliates - sediments - cell culture - tissue cultures 31 Filtersets for Wilovert AFL 34 Components for upgrading the inverted microscopes - objectives - condensers and accessories - object guide - holding frames - eyepieces - pointing, measuering, counting and calibartion with graticules - tubes - discussion tube - trinocular tubes - adaptation of video and photo accessories - heating stage - light filters - polarisation - immersio oil and cleaning sets - accessory sets - halogen lamps, spare bulbs, mercury high pressure lamps 48 35 35 35 35 36 36 37 37 37 37 38 38 38 38 38 39 Incident light microscopes and workshop microscopes Product page Technical survey on the microscope stand configurations 41 Incident ligh microscopy - metallurgy - quality control of workpieces - quality control / production surveillance 42 Components for upgrade of incident light microscopes - objectives - eyepieces - pointing, measuring and counting with graticules - tubes - discussion tube - trinocular tubes - adaptation of video and photo accessories - spare bulbs Accessories for repair Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] 44 44 45 46 46 46 46 46 60-65 Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 2 Stereomicroscopes Product page Complete configurations stereo microscopes 48 Stereomicroscope head SK Wiloskop - F Zoom 49 Accessories for stereomicroscopes 49 Stands for stereomicroscope heads 49 External light sources for stereomicroscopes 50 Cameras Digital USB cameras - cameras with CMOS sensor - cameras with CCD sensor 54 Digital D-SLR cameras - camera with ASP - C sensor 54 Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 3 Technical survey on the microscope stand configurations Microscope for education Med-Prax Code no. 008.0314.0 Solid cast-metal stand for reliable standing and smooth microscopy. Coaxial coarse and fine focusing. The coarse focus drive can be adjusted individually. Height adjustment of the coarse drive 20 mm (totally). Height adjustment of the fine drive 1 µm per scale division. Binocular observation tube 360° rotatable. Tube 45° inclined. Tube factor 1x, interpupillary distance 55 mm - 75 mm adjustable. Diopter adjustment: each eyepiece tube can be adjusted individually. Quadruple revolving nosepiece. Mechanical stage 130 mm x 130 mm with ergonomically placed coaxial knobs. Adjustment range 50 mm x 78 mm. Vernier in x-y direction. Specimen holder with spring lever. Condenser NA 1,25 with aperture diaphragm. Condenser height adjustment with gear drive. Condenser can be Köhler adjusted by an adjusting plate (grid) on the illumination head The aperture diaphragm is projected in the rear focus plane. 6 V / 20 W halogen illumination with continuous brightness control. Laboratory microscopes Medicus series Medicus microscopes are characterised by premium quality mechanics. They can be upgraded to phase contrast, darkfield, LED-Fluorescence and to micro-photography. Stand configurations with pre-centered field diaphragm 018.0575.0 Solid cast-metal stand in classic swan-neck shape Coaxial coarse and fine focus drives. Height adjustment of the coarse drive 15 mm (total). Height adjustment tot. 15 mm of the fine focus drive 2 µm per scale division. Binocular observation tube 360° rotatable, inclination 30°, tube factor 1x. Interpupillary distance 55 mm - 75 mm, adjustable. Diopter adjustment at each eyepiece tube. Quadruple revolving nosepiece with ball bearing. Mechanical stage 130 mm x 130 mm with ergonomically placed coaxial knobs. Adjustment range 76 mm x 52 mm Specimen holder with spring lever. Condenser height adjustment with gear drive for exact adjustment according to Köhler. Integrated and centered field diaphragm. 6 V / 20 W halogen illumination with continuous brightness control. Stand configuration with adjustable field diaphragm As stand configuration 018.0575.0 but with costly illumination tube and centreable field diaphragm 018.0678.0 Laboratory microscopes series H 600 Code no. Solid, heavy cast-metal stand, rectangular shape for high expandability. Max. stability for smooth microscopy. Coaxial coarse and fine focusing. Height adjustment of the coarse drive 22 mm (total). Height adjustment of the fine drive 2 µm per scale division. Binocular observation tube 360° rotatable, inclination 30°, tube factor 1x. Interpupillary distance 55 mm - 75 mm adjustable at each observation tube. Quintuple nosepiece with ball track Mechanical stage 160 mm x 130 mm with ergonomically placed coaxial knobs. Adjustment range 76 mm x 52 mm Specimen holder with spring lever. Condenser height adjustment with gear drive for exact adjustment according to Köhler. Sophisticated illumination tube with centerable field diaphragm. 12 V / 30 W halogen illumination with continuous brightness control. The following microscope stand configurations are available: Microscope stand configuration H 600 /12-5 with five objectives, sloping to the back 018.0648.0 Microscope stand configuration H 600/5 as H 600/12-5 but with lowerable stage . Microscope stand configuration H 600 LL / 5 for external adaptation of lightsources, e.g. halogen lamphouses This configuration contains a light guide to prevent the specimen from being damaged by excessive heat 018.0861.0 Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data 018.0306.0 Issue April 2011 Page 4 Upright microscopes Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 5 Microscopes for education Main focus of the application: Schools and education Method of contrast: brightfield Microscope Med-Prax Code no. Price 008.0314.0 599 € 019.0764.0 62 € consisting of: Microscope stand configuration Med-Prax Revolving nosepiece 4x Binocular observation tube (45°, TF 1x) Eyepiece WF 10x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective A 40 / 0,65 spring loaded Objective A 100 / 1,25 Oil spring loaded Condenser NA 1,25 with aperture diaphragm Adjusting plate (grid) Instruction for use Dust cover Set of accessories for Med-Prax, consisting of: Mains cable with plug 1 spare lamp 6 V / 20 W 2 spare fuses Immersion oil nD 1,515, PCB-free, 10 ml Components for further extension Plano concave mirror, adaptable to illumination tube. This allows sunlight to be used for illumination. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 6 Microscope for the medical practice Main focus of the application: haematology Method of contrast: brightfield Medicus HF Code no. Price 008.0095.0 920 € with achromatic objectives consisting of: Microscope stand configuration: Vc Binocular tube (30°TF1x) Eyepiece WF 10x / 18 2x Objective AC 4 / 0,10 Objective AC 10 / 0,25 Objective AC 40 / 0,65 spring loaded Objective AC 100 / 1,25 Oil spring loaded Condenser NA 1,25 - 0.0 with aperture diaphragm Set of accessories VI Instruction for use Dust cover 018.0575.0 019.0558.0 018.0425.0 018.0421.0 018.0422.0 018.0423.0 018.0424.0 018.0505.0 018.9313.0 901.1057.0 902.96066 Medicus HF PL 20 008.0342.0 1.425 € with plan-achromatic objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration:Vc Binocular tube (30°TF1x) Eyepiece WF 10 x / 20 2x Objective Plan 10 / 0,25 Objective Plan 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Condenser NA 1,25 with aperture diaphragm and filterholder Set of accessories V I Instruction for use Dust cover H 600 Wilo-Prax Achro 018.0575.0 019.0558.0 019.9037.000 019.9058.000 019.9060.000 019.9062.000 019.0193.0 018.9313.0 901.1041.0 902.96066 008.0372.0 2.020 € with high quality achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 4 / 0,10 Objective Achro 10 / 0,25 Objective Achro 40 / 0,65 spring loaded Objective Achro 100 / 1,25 (Oil) spring loaded Condenser NA 0,9 Set of accessories H Instruction for use Dust cover Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] 018.0648.0 018.0033.0 018.0425.0 019.9051.000 019.9052.000 019.9054.000 019.9056.000 018.0028.0 018.9011.0 901.1046.0 902.0052.0 Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 7 Microscopes for medical practice and hospitals Main focus of the application: haematology, urology Method of contrast: brightfield, phase contrast Urine sediments can be observed in better contrast, when working in phase contrast, in comparison to mere brightfield. Medicus PH Achro PL Code no. Price 008.0344.0 1.250 € with high quality achromatic objectives and one plan phase contrast objective 40x consisting of: Microscope stand configuration: Vv Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective Plan Ph3 40 / 0,65 spring loaded Objective Achro 100 / 1,25 (Oil) spring loaded Condenser NA 0.9 with aperture diaphragm and filterholder Insert diaphragm for phase contrast (to be inserted in the filterholder of the condenser) for objective Plan Ph3 40 Set of accessories V I Instruction for use Dust cover 018.0678.0 019.0558.0 018.0425.0 019.9052.000 019.9068.000 019.9056.000 018.0028.0 018.0767.0 018.9313.0 901.1041.0 902.96066 Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not contained in the price of the microscope. 018.96149 135 € Medicus PH Plan 008.0345.0 1.395 € with plan-achromatic objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration: Vv Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan Ph3 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Condenser NA 0.9 with aperture diaphragm and filterholder Insert diaphragm for phase contrast (to be inserted in the filterholder of the condenser) for objective Plan Ph3 40 Set of accessories V I Instruction for use Dust cover Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not contained in the price of the microscope. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data 018.0678.0 019.0558.0 019.9037.000 019.9058.000 019.9068.000 019.9062.000 018.0028.0 018.0767.0 018.9313.0 901.1041.0 902.96066 018.96149 135 € Issue April 2011 Page 8 Microscopes for shared laboratories and hospitals H 600 Wilozyt Plan 008.0380.0 2.755 € with plan-achromatic objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration: H 600/12-5 Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan Ph2 20 / 0,40 Objective Plan Ph3 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Small combination condenser NA 1,25 with aperture diaphragm and filterholder, can be switched from brightfield to phase contrast Set of accessories H Instruction for use Dust cover 018.0648.0 018.0033.0 019.9037.000 019.9058.000 019.9067.000 019.9068.000 019.9062.000 018.0639.0 018.9011.0 901.1046.0 902.0052.0 Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not contained in the price of the microscope. 018.96149 135 € H 600 Wilozyt Plan ICS 008.0381.0 3.140 € with infinity corrected plan-achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Tube optics for infinity corrected objectives Eyepiece WF 10 / 18 2x Objective ICS PL 10 / 0,25 Objective ICS PL Ph2 20 / 0,40 Objective ICS PL Ph3 40 / 0,65 spring loaded Objective ICS PL 100 / 1,25 (Oil) spring loaded Small combination condenser NA 1,25 with aperture diaphragm and filterholder, can be switched from brightfield to phase contrast Set of accessories H Instruction for use Dust cover Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not contained in the price of the microscope. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data 018.0648.0 018.0033.0 018.0547.0 018.96226 019.9046.000 019.9071.000 019.9072.000 019.9049.000 018.0639.0 018.9011.0 901.1046.0 902.0052.0 018.96149 135 € Issue April 2011 Page 9 Microscopes for pathology and bacteriology Method of contrast: brightfield Code number H 600 Wilo-Prax PL 008.0390.0 Price 2.185 € with plan-achromatic objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 20 Objective Plan 4 / 0,10 Objective Plan 10 / 0,25 Objective Plan 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Condenser NA 0,9 Set of accessories H Instruction for use Dust cover 018.0648.0 018.0033.0 019.9037.000 019.9057.000 019.9058.000 019.9060.000 019.9062.000 018.0028.0 018.9011.0 901.1046.0 902.0052.0 2x Equipment for detection of mycoses: Compact fluorescence illuminator with LED light source (395 nm), TF 1x, with beam splitter 400 nm, barrier filter LP 580 nm and power supply 018.0837.0 1.495 € Fluorescence dye (fluorochrome) Mykoval 10 ml 902.0067.0 95 € H 600 Wilo-Prax ICS 008.0414.0 2.950 € with infinity corrected plan-achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Tube optics for infinity objectives Eyepiece WF 10 x / 18; 2 pcs. Objective ICS PL 4 / 0,10 Objective ICS PL 10 / 0,25 Objective ICS PL 40 / 0,65 Objective ICS PL 100 / 1,25 Oil, spring loaded Condenser 0,9 Set of accessories H Instruction for use Dust cover Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] 2x Subject to change without notice Right reserved to modify technical data 018.0648.0 018.0033.0 018.0547.0 018.0425.0 019.9045.000 019.9046.000 019.9048.000 019.9049.000 018.0028.0 018.9011.0 901.1046.0 902.0052.0 Issue April 2011 Page 10 Method of contrast: brightfield, phase contrast Code number H 600 PH Plan 008.0353.0 Price 2.995 € with plan-achromatic phase contrast objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 20 2x Objective Plan Ph1 10 / 0,10 Objective Plan Ph3 40 / 0,65 spring loaded Objective Plan Ph4 100 / 1,25 Oil spring loaded Large combination condenser NA 1,25 with aperture diaphragm and filterholder, switchable for brightfield and phase contrast with centering telescope Set of accessories H Instruction for use Dust cover 018.0648.0 018.0033.0 019.9037.000 019.9066.000 019.9068.000 019.9069.000 018.0835.0 018.9010.0 901.1046.0 902.0052.0 Method of contrast: brightfield, phase contrast, incident fluorescence light H 600 AFL PH Plan 50 008.0354.0 6.265 € with plan-achromatic phase contrast objectives consisting of: Microscope stand configuration H 600/12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan Ph2 20 / 0,40 Objective Plan Ph3 40 / 0,65 spring loaded Objective Plan Ph4 100 / 1,25 Oil spring loaded Large combination condenser NA 1,25 with aperture diaphragm and filterholder, switchable for brightfield and phase contrast with centering telescope Incident fluorescence illuminator for filterslider Filterslider for up to 2 filterblocks Filterblock D for incident fluorescence light (FITC) Illumination unit HBO 50, consisting of: Lamphouse HBO 50 with collector, mirror, lampmount and heat protection filter Hg high pressure lamp 50 W Power supply HBO 50 including mains cable Set of accessories H / AFL Instruction for use Dust cover H 600 AFL PH Plan 100 018.0648.0 018.0033.0 019.9050.000 019.9058.000 019.9067.000 019.9068.000 019.9069.000 018.0835.0 018.0754.0 018.0745.0 018.0454.0 018.0237.0 662.96290 018.0373.0 018.9014.0 901.1033.0 902.96670 008.0382.0 7.340 € Same configuration as H 600 AFL Plan 50 but with illumination system HBO 100 Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 11 Equipment for immunology Method of contrast: brightfield, incident fluorescence light Code number H 600 AFL Achro 50 008.0355.0 Price 5.645 € with high quality achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective Achro 40 / 0,65 spring loaded Objective Achro 100 / 1,25 (Oil) spring loaded Condenser NA 1,25 Incident fluorescence illuminator for filterslider Filterslider for up to 2 filterblocks Filterblock D for incident fluorescence light (FITC) Illumination unit HBO 50, consisting of: Lamphouse HBO 50 with collector, rear mirror, lamp mount and heat protection filter Hg high pressure mercury lamp 50 W Power supply unit HBO 50 including mains cable Set of accessories H / AFL Instruction for use Dust cover H 600 AFL Achro 100 018.0648.0 018.0033.0 019.9050.000 019.9052.000 019.9054.000 019.9056.000 019.0193.0 018.0754.0 018.0745.0 018.0454.0 018.0237.0 662.96290 018.0373.0 018.9014.0 901.1033.0 902.96670 008.0383.0 6.720 € 008.0356.0 5.850 € 008.0384.0 6.925 € 008.0357.0 6.160 € 008.0385.0 7.235 € Same configuration as H 600 AFL Achro 50, but with illumination unit HBO 100 H 600 AFL Plan 50 Same configuration as H 600 AFL Achro 50 but with plan achromatic objectives H 600 AFL Plan 100 Same configuration as H 600 AFL Plan 50, but with illumination unit HBO 100 H 600 AFL Plan ICS 50 Same configuration as H 600 AFL Achro 50 but with infinity corrected plan-achromatic objectives H 600 AFL Plan ICS 100 Same configuration as H 600 AFL Plan ICS 50, but with illumination unit HBO 100 and infinity corrected plan-achromatic objectives Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 12 H 600 AFL PH 40 Plan 50 008.0359.0 5.935 € with plan-achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan Ph 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Small combination condenser NA 0,9 for brightfield and phase contrast Incident fluorescence illuminator for filterslider Filterslider for up to 2 filterblocks Filterblock D for incident fluorescence light (FITC) Illumination unit HBO 50, consisting of: Lamphouse HBO 50 with collector, rear mirror, lamp mount and heat protection filter Hg high pressure mercury lamp 50 W Power supply unit HBO 50 including mains cable Set of accessories H / AFL Instruction for use Dust cover 018.0648.0 018.0033.0 019.9050.000 019.9058.000 019.9068.000 019.9062.000 019.0072.0 018.0754.0 018.0745.0 018.0454.0 018.0237.0 662.96290 018.0373.0 018.9014.0 901.1033.0 902.96670 Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope. 018.96149 135 € H 600 AFL PH 40 Plan 100 008.0387.0 7.020 € 008.0360.0 6.245 € 008.0388.0 7.330 € Code number 018.0451.0 Price 815 € Filterset D (FITC) Excitation range 450 - 490 nm, Dichroic mirror 510 nm, suppression filter 520 nm 018.0454.0 485 € Filterset E (TRITC) Excitation range 515 - 560 nm, Dichroic mirror 580 nm, suppression filter 580 nm 018.0455.0 485 € Filterset G (Mykoval) Excitation range 355 - 425 nm, Dichroic mirror 400 nm, suppression filter 455 nm 018.0442.0 485 € Filterset Texas Red Excitation range 540 - 580 nm Dichroic mirror 595 nm, suppression filter 600 - 660 nm 018.0602.0 1.125 € Filterset Rhodamin (red version) Excitation range 546 nm, Dichroic mirror 565 nm, suppression filter 600 - 660 nm 018.0603.0 1.125 € Same equipment as H 600 AFL PH Achro 50, but with illumination unit HBO 100 H 600 AFL PH Plan ICS 50 Same equipment as H 600 AFL PH Plan 50 but with plan-achromatic objectives, infinity corrected H 600 AFL PH Plan ICS 100 Same equipment as H 600 AFL Plan ICS 50, but with illumination unit HBO 100 and plan-achromatic objectives, infinity corrected Filtersets for H 600 AFL Filterset A (DAPI) Excitation range 340 - 380 nm, Dichroic mirror 400 nm, suppression filter 435 - 485 nm Further filterblocks upon request Incorporation of further filtersets (per filterset) 60 € Filterslider for fluorescence Filterslider for 2 filtersets 018.0745.0 365 € Filterslider for 4 filtersets 018.0746.0 550 € Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 13 Microscopes with heating stage Main focus of the application: living specimens, fertility investigations Method of contrast: brightfield, phase contrast Code number Medicus PH Plan HT 008.0361.0 Price 2.350 € with plan-achromatic objectives consisting of: Microscope stand configuration: Vv Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan 20 / 0,40 Objective Plan Ph3 40 / 0,65 spring loaded Small combination condenser NA 0,9 with aperture diaphragm and filterholder for brightfield and phase contrast Small heating stage HT 50 up to 50°C Control unit for HT 50, Input 100-240 V AC / 0,4 A, Output 12 V DC / 1,25 A Set of accessories V III Instruction for use Dust cover Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data 018.0678.0 019.0558.0 018.0425.0 019.9058.000 019.9059.000 019.9068.000 018.0287.1 018.0465.0 018.0655.0 018.9307.0 901.1014.0 902.96066 018.96149 135 € Issue April 2011 Page 14 LED-incident light fluorescence Method of contrast: brightfield, incident fluorescence with LED Code number Medicus LED AFL Myko 008.0364.0 Price 2.485 € with high quality achromatic objectives consisting of: Microscope stand configuration Vv Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2 pieces Objective Achro 20 / 0,40 Objective Achro 40 / 0,65 spring loaded Condenser NA 0,9 Compact incident fluorescence illuminator with LED lightsource (395 nm), TF 1x, with: dichroic mirror 400 nm, suppression filter LP 580 nm and power supply unit Fluorescence dye (fluorochrome) Mykoval 10 ml Set of accessories V I Instruction for use Dust cover Medicus LED AFL FITC 018.0575.0 019.0558.0 018.96226 019.9053.000 019.9054.000 018.0028.0 018.0837.0 632.0024.0 902.0067.0 018.9313.0 901.1041.0 902.96066 008.0405.0 2.585 € 008.0406.0 2.585 € 008.0407.0 2.635 € 008.0378.0 2.915 € Same configuration as Medicus AFL Myko but with LED-Fluorescence-Illuminator FITC Medicus LED AFL TRITC Same configuration as Medicus AFL Myko but with LED-Fluorescence-Illuminator TRITC Medicus LED AFL DAPI Same configuration as Medicus AFL Myko but with LED-Fluorescence-Illuminator DAPI Method of contrast: brightfield, phase contrast, incident fluorescence with LED Medicus PH LED AFL Myko with high quality achromatic objectives and one plan phase contrast objective 40 x consisting of: Microscope stand configuration Vv Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2 pieces Objective Achro 10 / 0,25 Objective Plan Ph 40 / 0,65 spring loaded Objective Plan 40 /0,65 spring loaded Condenser NA 0.9 with aperture diaphragm and filterholder Drop-in diaphragm for phase contrast (to be inserted in the filterholder of the condenser) for objective Plan Ph2 40 Compact incident fluorescence illuminator with LED-lightsource (395 nm), TF 1x, with: dichroic mirror 400 nm, suppression filter LP 580 nm and power supply unit Fluorescence dye (fluorochrome) Mykoval 10 ml Set of accessories V I Instruction for use Dust cover 018.0678.0 019.0558.0 018.96226 019.9052.000 019.9068.000 019.9060.000 018.0028.0 018.0767.0 018.0837.0 902.0067.0 018.9313.0 901.1041.0 902.96066 Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope. 018.96149 135 € Medicus PH LED AFL FITC 008.0408.0 3.015 € 008.0409.0 3.015 € 008.0410.0 3.065 € Same configuration as Medicus PH LED AFL Myko but with LED-Fluorescence-Illuminator FITC Medicus PH LED AFL TRITC Same configuration as Medicus PH LED AFL Myko but with LED-Fluorescence-Illuminator TRITC Medicus PH LED AFL DAPI Same configuration as Medicus PH LED AFL Myko but with LED-Fluorescence-Illuminator Dapi Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 15 Method of contrast: brightfield, incident fluorescence with LED H 600 LED AFL Myko consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective SPL 20 / 0,50 Objective Achro 40 / 0,65 spring loaded Condenser NA 0,9 Compact incident fluorescence illuminator with LED lightsource (395 nm), TF 1x, with: dichroic mirror 400 nm, suppression filter LP 580 nm and power supply unit Fluorescence dye (fluorochrome) Mykoval 10 ml Set of accessories H Instruction for use Dust cover H 600 LED AFL FITC Code number Price 008.0365.0 3.595 € 018.0648.0 018.0033.0 018.96226 019.0532.0 019.9054.000 018.0028.0 018.0837.0 902.0067.0 018.9011.0 901.1041.0 902.96670 008.0411.0 3.695 € 008.0412.0 3.695 € 008.0413.0 3.750 € Same configuration as H 600 LED AFL Myko but with LED-Fluorescence-Illuminator FITC H 600 LED AFL TRITC Same configuration as H 600 LED AFL Myko but with LED-Fluorescence-Illuminator TRITC H 600 LED AFL DAPI Same configuration as H 600 LED AFL Myko but with LED-Fluorescence-Illuminator DAPI Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 16 Equipment for investigations of native blood in darkfield Main focus of the application: investigation of native blood in darkfield acc. to Prof. Enderlein H 600 LL HP 100 consisting of: Microscope stand configuration H 600 LL / 5 Trinocular tube (360° TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective SPL 100 / 1,25-0,60 (Oil) with iris diaphragm, spring loaded Darkfield condenser NA 1,4 Collector II Halogen illumination 12 V / 100 W, consisting of: Lamphouse HAL 100 with collector, rear mirror, lamp mount and heat protection filter Power supply unit for halogen lamp 12 V / 100 W, halogen lamp 12 V / 100 W Set of accessories H LL Instruction for use Dust cover Code number Price 008.0368.0 4.420 € 018.0306.0 018.0033.0 018.96226 019.9052.000 019.0489.0 019.0182.0 018.0276.0 018.0324.0 018.9018.0 901.1038.0 902.96670 Equipment for investigations of microorganisms in liquids Main focus of the application: breweries Method of contrast: brightfield, phase contrast, darkfield H 600 Wilo-Brau consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective Plan Ph 3 40 / 0,65 spring loaded Objective A 63 / 0,85 spring loaded Small combination condenser NA 1,25 with aperture diaphragm and filterholder for brightfield, phase contrast and darkfield up to objective 63x (darkfield drop in diaphragm necessary) Darkfield drop in diaphragm for objective A 63 / 0,85 Set of accessories H Instruction for use Dust cover Code number Price 008.0370.0 2.465 € 018.0648.0 018.0033.0 018.0425.0 019.9052.000 019.9068.000 018.96640 018.0639.0 503.69465 018.9010.0 901.1046.0 902.0052.0 Main focus of the application: sewage treatment plants (activated sludge) Method of contrast: brightfield, phase contrast, darkfield H 600 BS 008.0371.0 consisting of: Microscope stand configuration H 600 / 12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective Plan Ph 3 40 / 0,65 spring loaded Objective Plan Ph 4 100 / 1,25 Oil spring loaded Large combination condenser NA 0,9 (HF, DF, PH 3 / 4) Set of accessories H BS Instruction for use Dust cover Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data 2.830 € 018.0648.0 018.0033.0 018.0425.0 019.9052.000 019.9068.000 019.9069.000 018.0818.0 018.9013.0 901.1046.0 902.0052.0 Issue April 2011 Page 17 Polarising microscopes Laboratory microscopes for investigations in polarised light Method of contrast: brightfield, polarisation (orthoscopical investigations) H 600 POL consisting of: Microscope stand configuration H 600 / 12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 Objective Plan 10 / 0,25 Objective Plan 20 / 0,40 spring loaded Objective Plan 40 / 0,65 spring loaded Objective Plan 60 / 0,85 spring loaded Condenser NA 1,25 Code number Price 008.0286.0 3.720 € 018.0648.0 018.0033.0 018.0425.0 019.9058.000 019.9059.000 019.9060.000 019.9061.000 019.0193.0 2x Large polarising equipment HP I, consisting of: - polariser, rotatable, can be attached to the condenser - analyser, can be rotated 90° Round centering and rotating stage with scale (360°) and vernier Object guide for round centering and rotating stage with low positioned control knobs Set of accessories H Instruction for use Dust cover Optional: Centering telescope for conoscopical investigations. Can be used instead of a Bertrand lens. 019.0115.0 019.0178.0 019.96280 018.9011.0 901.1076.0 902.96670 018.96149 135 € 008.0243.0 4.855 € Laboratory microscopes for investigations in polarised light with powerful lightsource. Method of contrast: brightfield, polarisation (orthoscopical) H 600 LL POL 50 consisting of: Microscope stand configuration H 600 LL / 5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 Objective Plan 10 / 0,25 Objective Plan 20 / 0,40 spring loaded Objective Plan 40 / 0,65 spring loaded Objective Plan 60 / 0,85 spring loaded Condenser NA 1,25 Collector II 018.0306.0 018.0033.0 018.0425.0 019.9058.000 019.9059.000 019.9060.000 019.9061.000 019.0193.0 018.0276.0 2x Halogen illumination 12 V / 50 W Lamphouse HAL 50 with collector, reflector, lampmount and heat protection filter halogen lamp 12 V / 50 W Power supply for halogen lamp 12 V / 50 W 018.0323.0 Large polarising equipment HP I, consisting of: - polariser, rotatable, can be attached to the condenser - analyser, can be rotated 90° - box for storage Round centering and rotating stage with scale (360°) and vernier Object guide for round centering and rotating stage with low positioned control knobs Set of accessories H Instruction for use Dust cover 019.0115.0 019.0178.0 019.96280 018.9017.0 901.1077.0 902.96670 Optional: Centering telescope for conoscopical investigations. Can be used instead of a Bertrand lens. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data 018.96149 135 € Issue April 2011 Page 18 Polarising microscopy - components The modular concept of the Hund microscope program offers attachment of components for polarising microscopy for existing microscopes. This is valid for orientating polarisation in biology, medicine and metallurgy. Rotatable and centerable stage with scale division (360°) and vernier. 019.0178.0 550 € Object guide for rotatable and centerable stage with flat control knobs. 019.96280 365 € 018.96177 105 € 019.0115.0 640 € Small polarising equipment HP II, consisting of: > polariser with arm, that can be placed on the illumination head > analyser on filterslider, that can be placed in the tube slot of the microscope 019.0106.0 95 € Filter Slider with polariser for incident light 018.0666.0 120 € For microscopes series V (Medicus, Vb 365, etc): Small polarising equipment WP II consisting of: > polariser, that can be placed in the filterholder of the condenser > analyser, that can be placed on the eyepiece For microscopes series H 600: Large polarising equipment HP I, consisting of: > rotatable polariser, that can be attached to the condenser > analyser 90° rotatable (disengageable) > compensator 1st order red (disengageable) > storage case Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 19 Components for further upgrade of upright microscopes Objectives High quality Achro-objectives Tube length 160 mm These objectives are high quality achromatic objectives, which are outstanding for their excellent image quality. These objectives can be used with eyepieces with the field of view 20. Achro 4/0,10 019.9051.000 41 € Achro 10/0,25 019.9052.000 52 € Achro 20/0,40 019.9053.000 62 € Achro 40/0,65 spring loaded 019.9054.000 72 € Achro 60/0,85 spring loaded 019.9055.000 93 € 019.9056.000 103 € Achro 100/1,25 Oil, spring loaded Recommended eyepieces: 018.96763.1 / 019.9037.000 Plan-objectives Tube length 160 mm Plan-achromatic objectives for highest demands. These objectives can be used with eyepieces with field of view 20. Plan 2,5/0,07 019.9999.090 160 € Plan 4/0,10 019.9057.000 52 € Plan 10/0,25 019.9058.000 82 € Plan 20/0,40 019.9059.000 125 € Plan 40/0,65 spring loaded 019.9060.000 155 € Plan 60/0,85 spring loaded 019.9061.000 200 € Plan 100/1,25 Oil, spring loaded Recommended eyepieces: 019.9037.000 / 018.96763.1 019.9062.000 230 € Code number 019.0489.0 Price 715 € 019.9999.128 350 € 019.9054.000 72 € 018.96659 230 € Components for further upgrade of upright microscopes Special objectives SPL Objektive for darkfield with highest magnifications : SPL 100 / 1,25-0,60 Oil with iris diaphragm For low magnification : S-Plan 2/0,05 For use in combination with counting chambers : A 40/0,65 spring loaded A Ph2 40/0,65 spring loaded Recommended eyepiece: 018.0425.0 Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 20 ICS PL-Objectives Tube length: infinity High quality plan-achromatic objectives, infinity corrected ICS PL 4/0,10 019.9045.000 93 € ICS PL 10/0,25 019.9046.000 105 € ICS PL 20/0,45 019.9047.000 210 € ICS PL 40/0,65 spring loaded 019.9048.000 250 € 019.9049.000 310 € SPL 20/0,50 019.0532.0 290 € FL 50/1,0 Oil, spring loaded 019.0070.0 505 € ICS PL 100/1,25 Oil spring loaded Recommended eyepieces: 018.96226 / 019.9050.000 / 019.9050.000 Fluorite objective FL-objective Tube length 160 mm for haematological investigations and fluorescence microscopy Phase contrast objectives Plan-achromatic phase contrast objectives Tube length 160 mm PL Ph 1 10/0,25 019.9066.000 125 € PL Ph 2 20/0,35 019.9067.000 155 € PL Ph 3 40/0,65 spring loaded 019.9068.000 200 € 019.9069.000 250 € PL Ph 4 100/1,25 Oil, spring loaded Recommended eyepieces: 019.9050.000 / 019.9037.000 Plan-achromatic ICS-phase contrast objectives (Tube length: infinity) ICS PL Ph 1 10/0,25 019.9070.000 200 € ICS PL Ph 2 20/0,35 019.9071.000 250 € ICS PL Ph 3 40/0,65 spring loaded 019.9072.000 340 € 019.9073.000 455 € ICS PL PH 4 100/1,25 Oil spring loaded Recommended eyepieces: 019.9050.000 / 019.9037.000 Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 21 Condensers and accessories Brightfield condensers with aperture diaphragm and filterholder Code number 018.0028.0 Price 82 € 019.0193.0 125 € 018.0125.0 10 € Small combination condenser NA 0,9 for all brightfield objectives and for phase contrast with two objectives, if no immersion oil is used for the condenser. 019.0072.0 290 € Small combination condenser NA 1,25 for all brightfield objectives and for phase contrast with objectives A Ph2 20x, A Ph2 40x and darkfield up to objective A 40x. A ground glass filter should be inserted into the filterholder of the condenser, when using the 4x objective. 018.0834.0 290 € Ground glass filter, diameter 32 mm (in box) 018.0125.0 10 € 019.9063.000 375 € Large combination condenser NA 0,9 for all brightfield objectives and for phase contrast objectives 10:1, 20:1, 40:1, 100:1. Case for large combination condenser 018.0710.0 018.96586 445 € 41 € Large combination condenser NA 1,25 for all brightfield objectives and for phase contrast objectives 10:1, 20:1, 40:1, 100:1, resp. for 3 phase contrast objectives & darkfield up to 40:1. 018.0835.0 455 € Centering telescope for adjusting phase contrast. Can be used instead of Betrand lens. 018.96149 135 € 019.0182.0 445 € Conversion filter BG 28, diameter 32 mm (in box) 019.0363.0 10 € Conversion filter BG 28 and ground glass filter, diameter 32 mm (in box) 018.96089 21 € Green filter VG 9, diameter 32 mm (in box) 018.96173 21 € Ground glass filter, diameter 32 mm (in box) 018.0125.0 10 € Filterslider II with conversion filter BG 28 and green filter VG 9 to be inserted in the upper part of upper part of the microscope stand 018.0123.0 31 € Yellow filter, diameter 32 mm (in box) 018.0782.0 10 € 019.9075.000 21 € Condenser NA 0,9 for all brightfield objectives also for objectives 100:1, if no immersion oil for the condenser is used. Condenser NA 1,25 recommended for all brightfield objectives from 10 x if high NA's are required. For the objective 4x, a ground glass filter must be placed in the filterholder of the condenser. Ground glass filter, diameter 32 mm (in box) Combination condensers for brightfield, phase contrast and darkfield with aperture diaphragm and filterholder Phase contrast condenser NA 1.25 for plan objectives (160 mm tube length) with centering telescope Special darkfield condensers Darkfield condenser NA 1,4 for brilliant darkfield with objective 100x with iris diaphragm. Light filters Eyepieces H5x WF 10 x / 18 pupil distance 13 mm simple style 018.0425.0 21 € WF 10 x / 18 pupil distance 13 mm 018.96226 82 € WF 10 x / 18 B pupil distance 24 mm for spectacle wearers 018.96792 105 € WF 10 x / 18 pupil distance 13 mm 019.9050.000 31 € WF 12,5 x / 18, pupil distance 11 mm 018.96284 185 € WF 12,5 x / 18 B, pupil distance 24 mm for spectacle wearers 018.96794 210 € WF 10 x / 20 M 019.9037.000 41 € WF 15 x / 17, pupil distance 11 mm 018.96500 93 € Eyeguards, benzene-and xylol-proof Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] 902.97300 Subject to change without notice Right reserved to modify technical data 5€ Issue April 2011 Page 22 Components for further upgrade of upright microscopes Pointing, measuring, counting and calibration with graticules Measuring eyepieces differ from normal eyepieces in their construction. Therefore they cannot be used combined with normal eyepieces. For observation with two eyes a second measuring eyepiece without graticule, used as a complement eyepiece, is necessary. Pointing Code number 018.0712.0 Price 105 € 018.96226 82 € 018.0478.001 240 € 018.0478.0 210 € Micrometer eyepiece WF10x / 18 with cross hair contains graticule 059.0032.0 Complement eyepiece WF 10 x / 18 018.0478.002 240 € 018.0478.0 210 € Micrometer eyepiece WF10x / 18 10 mm = 100 divisions contains graticule 059.14054 Complement eyepiece WF 10 x / 18 018.0478.003 240 € 018.0478.0 210 € Code number 018.0478.005 Price 260 € 018.0478.0 210 € 018.0478.004 405 € 018.0478.0 210 € Stage micrometer for transmitted light 1 mm = 100 divisions 2 mm = 200 divisions 019.96133 019.96723 93 € 105 € Stage micrometer for incident light 1 mm = 100 divisions 019.96843 93 € WF 10 x / 18 with pointer contains pointer 503.0226.0 Complement eyepiece WF 10 x / 18 (for SPL and PL-objectives) Cross hair eyepiece WF 10x / 18 contains graticule 059.14053 Complement eyepiece WF 10 x / 18 Measuring Eyepieces shown above are also available at 12,5x Components for further upgrade of upright microscopes Counting Counting eyepiece WF 10x 10 x 10 lines; 10 mm x 10 mm contains graticule 059.14057 Complement eyepiece WF 10 x Eyepiece WF 10x G 22 Walton and Beckett contains graticule 059.0108.0 Complement eyepiece WF 10 x 20x3 10x3 5x5/ 5 7 9 Calibration Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 23 Components for further upgrade of upright microscopes Tubes Binocular tube C inclined 30°, TF=1x 019.0558.0 210 € Binocular tube H inclined 30°, TF=1x 018.0033.0 405 € 018.0467.0 1.515 € 902.0079.0 15 € Trinocular phototube 30 / 70 inclined 30°, TF=1x, beam splitting 30% visual / 70% documentation (fixed) 018.0034.0 610 € Trinocular phototube 100 / 100 inclined 30°, TF=1x, beam splitting 100% visual / 100% documentation (changeable) 019.0505.0 875 € 018.0810.0 215 € Video-adapter without intermediate optics (1x) (C-Mount) for trinocular phototubes 019.0094.0 93 € Video-adapter with intermediate optics 0,5x (C-Mount) for trinocular phototubes 019.0453.0 105 € Video-adapter with intermediate optics 1,6x (C-Mount) for trinocular phototubes 019.0442.0 175 € 018.0837.0 1.495 € Fluorescence dye (fluorochrome) Mycoval 10 ml 902.0067.0 93 € LED incident light fluorescence-illuminator FITC 018.0839.0 1.600 € 018.0840.0 1.600 € 018.0838.0 1.650 € For education of a second observer Discussion bridge DB 2 for a 2nd observer with pointer, that can be operated by both observers Dust cover for discussion bridge The discussion bridge can be adapted to all professional laboratory microscopes. For information please contact our technical service. Trinocular tubes Tubes for adaptation of photo- or video equipment Equipment for photomicrography Prerequisite: Tube for adaptation of photo- respectively video equipment For adaptation of SLR cameras Adapter set for Canon SLR cameras incl. Photo eyepiece T 2 adapter for adaptation of other SLR-cameras to phototubes upon request. For adaptation of cameras pls. contact our technical service Adaptation of video- and photo systems in combination with trinocular phototube 018.0034.0 / 019.0505.0 or replacement tube For adaptation of photo equipment please contact our technical service. LED-Fluorescence-Illuminators LED incident light fluorescence illuminator Myko LED light source (365 nm), TF 1x, with filter set for Mykoval and wall power supply Fluorescence dye/ Mycoval LED lightsourec (470 nm), TF 1x, with filter set for FITC and wall power supply LED incident light fluorescence-illuminator TRITC LED lightsourec (530 nm), TF 1x, with filter set for TRITC and wall power supply LED incident light fluorescence-illuminator DAPI LED lightsourec (365 nm), TF 1x, with filter set for DAPI and wall power supply Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 24 Attachable mirror for illumination via external light sources for example the sun Plano concave mirror is placed on the illumination tube of the microscopes V and H. Diameter 50 mm 018.0348.0 62 € Immersion oil nD 1,515 PCB-free, 10 ml 902.0066.0 15 € Faxo-Clean cleaning liquid 30 ml 902.0065.0 8€ 019.9999.132 41 € Specimen holder, metal for 2 specimens 018.0263.0 21 € Specimen holder, plastic, chromed for 1 specimen 018.0383.0 31 € 018.0655.0 018.0465.0 018.0664.0 330 € 270 € 540 € 019.0501.0 2.390 € Code number Price Wooden cabinet for Med-Prax 902.0099.0 103 € Wooden cabinet for V-microscopes 902.96070 103 € Wooden cabinet for H 600 902.0073.0 103 € Case for transportation (plastic, black) 902.0039.0 82 € Dust cover for V-microscopes 902.96066 10 € Dust cover for H 600 / stereomicroscopes 902.0052.0 10 € Dust cover H 600 AFL, H 600 LL 902.96670 10 € Dust cover for microscope with discussion bridge DB 2 902.0079.0 15 € Interior packing (styrofoam) 905.0025.0 21 € Immersion oil and cleaning liquids Optical cleaning set, consisting of: Cleaning liquid 30 ml Anti-static cleaning cloth Anti-static brush Grabber stick for absorbing dust particles Specimen holders Heating stages for upright microscopes Small heating stage HT 50 (up to 50°C) adaptable to microscope stage, consisting of: Control unit (including mains cable, Input 100 V-240 V AC / 0,4 A Output 12 V DC / 1,25 A) Small heating stage HT 50 (incl mains cable 12 V / 15 W) Optional: Warming plate (incl. mains cable 12 V / 30 W) Large heating stage HMT-H with control unit HT 200 and pre-heating plate Separate regulation of the heating stage 43° and pre-heating plate 48° C in steps of 0,5°C from ambient temperature to 50°C. Digital temperature selection and display for the heating stage and the warming plate. Temperature constancy +/- 0,2°C For storage and transport Wooden cabinets, cases for transportation, dust covers Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 25 Sets of accessories for the microscopes Medicus Microscopes Code number 018.9313.0 625.56362 662.0003.0 018.0369.0 019.0120.0 902.0066.0 Price 42,30 € 10,20 € 11,00 € 3,50 € 2,60 € 15,00 € Set of accessories V II Mains cable with safety plug 1 halogen lamp 6 V / 20 W (spare) 2 spare fuses 230 V, 0,2 ATR 2 centering keys SW 1,5 Conversion filter BG 28 and ground glass filter, diameter 32 mm (in box) Immersion oil nD 1,515, PCB-free, 10 ml 018.9322.0 625.56362 662.0003.0 018.0369.0 019.0120.0 018.96089 902.0066.0 62,30 € 10,20 € 11,00 € 3,50 € 2,60 € 20,00 € 15,00 € Set of accessories V III Mains cable with safety plug 1 halogen lamp 6 V / 20 W (spare) 2 spare fuses 230 V, 0,2 ATR 2 centering keys SW 1,5 Conversion filter BG 28 and ground glass filter, diameter 32 mm (in box) Green filter VG 9 Immersion oil nD 1,515, PCB-free, 10 ml 018.9307.0 625.56362 662.0003.0 018.0369.0 019.0120.0 018.96089 018.96173 902.0066.0 82,30 € 10,20 € 11,00 € 3,50 € 2,60 € 20,00 € 20,00 € 15,00 € Set of accessories H Mains cable with safety plug 1 halogen lamp 12 V / 30 W (spare) 2 spare fuses 230 V, 0,2 ATR 2 centering keys SW 1,5 Filterslider II H 600 with conversion filter BG 28 and green filter VG 9 Ground glass filter in box Immersion oil nD 1,515, PCB-free, 10 ml Eyeguards, benzene and xylol-proof, 2 pieces 018.9011.0 625.56362 662.0009.0 018.0369.0 019.0120.0 018.0123.0 018.0125.0 902.0066.0 902.97300 90,40 € 10,20 € 13,00 € 3,50 € 2,60 € 30,00 € 10,00 € 15,00 € 6,10 € Set of accessories H/AFL Mains cable with safety plug 1 halogen lamp 12 V / 30 W (spare) 2 spare fuses 230 V, 0,2 ATR Immersion oil nD 1,515, PCB-free, 10 ml Eyeguards, benzene- and xylol-proof, 2 pieces Centering keys 1.5 Protective gloves Protective glasses 018.9014.0 625.56362 662.0009.0 018.0369.0 902.0066.0 902.97300 018.55855 599.0017.0 599.0016.0 76,60 € 10,20 € 13,00 € 3,50 € 15,00 € 6,10 € 3,00 € 10,30 € 15,50 € Set of accessories H LL 2 centering keys SW 1,5 Immersion oil nD 1,515, PCB-free, 10 ml Eyeguards, benzene and xylol-proof, 2 pieces Filterslider II H 600 with conversion filter BG 28 and green filter VG 9 018.9018.0 019.0120.0 902.0066.0 902.97300 018.0123.0 45,40 € 2,60 € 15,00 € 6,10 € 29,00 € Set of accessories H LL NH 2 centering keys SW 1,5 Filterslider II H 600 with conversion filter BG 28 and green filter VG 9 Immersion oil nD 1,515, PCB-free, 10 ml Eyeguards, benzene and xylol-proof, 2 pieces 018.9019.0 019.0120.0 018.0123.0 902.0066.0 902.97300 52,70 € 2,60 € 29,00 € 15,00 € 6,10 € Set of accessories V I Mains cable with safety plug 1 halogen lamp 6 V / 20 W (spare) 2 spare fuses 230 V, 0,2 ATR 2 centering keys SW 1,5 Immersion oil nD 1,515, PCB-free, 10 ml H-Microscopes Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 26 Components for further upgrade of upright microscopes Halogen lamps Halogen lamp 6 V / 10 W socket G4 Single Set (6 pieces) Code number 662.96236 018.96277 Price 9€ 46 € 662.0003.0 018.96891 11,00 57 € 662.0010.0 018.0513.0 15 € 80 € 662.0009.0 13 € 662.96229 18 € 662.0005.0 18 € Suitable for: - V 300/C 300 until production date 11.99 / serial number 1008600 - BX 300 - Stereomicroscope stands SM-AD - Wilovert A until production date end 86 / serial number 200850 - S 200 Halogen lamp 6 V / 20 W socket G4 Single Set (6 pieces) Suitable for: - H 500 until 10.99 / 1008500 - V 300 / C 300 from 12.99 / 1008900 - Wilovert until 10.99 / 1008400 Halogen lamp 6 V / 30 W socket G4 Single Set (6 pieces) Suitable for: - H 600 from 11.99 / 1008550 Halogen lamp 12 V / 30 W socket G4 Suitable for: - Wilovert from 1.2000 / 1008600 - H 600 Halogen lamp 12 V / 50 W socket G 5,3 / 6,35 Suitable for: - H 600 LL, Incident illuminator AM, (at H 600 and WAD), Metallovert Halogen lamp 12 V / 100 W socket G 6,35 Suitable for: - H 600 LL, Wilovert LL, Incident illuminator AM, (at H 600 and WAD) Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 27 Components for further upgrade of upright microscopes Lamps Lamp 220 V / 15 W E14 Single Set (6 pieces) Code number 663.0001.0 018.96095 Price 6€ 29 € 661.96052 13 € 661.96004 018.96029 14 € 72 € 018.96005 25 € 663.96084 11 € 661.97310 11 € 662.96290 185 € 662.0006.0 210 € Suitable for: - Vb 150, Vb 155, Vb 250, Vm 250, attachable lamp 018.96230 and 018.96001 Lamp 6 V / 15 W E14 Suitable for : - V 100 (a transformer is prerequisite) Vb 100, Vb 150, BX 100 Lamp 6 V / 15 W Single Set (6 piece) BA 15 d Suitable for: - BX 200 (with round base and transformer) LTKU Lamp 6 V / 15 W centered socket Suitable for: - BX 200 incident illuminator WAD (old) Lamp 220 V / 20 W partially reflected BA 15 Suitable for: - Vb 250 K, Vb 250 R Lamp 6 V / 7 W Suitable for: - Stereomicroscope stand (old) Mercury high pressure lamps Hg-high pressure lamp 50 W Suitable for: - H 500 AFL 50, H 600 AFL 50, Wilovert AFL 50 Hg-high pressure lamp 100 W Suitable for: - H 500 AFL 100, H 600 AFL 100, Wilovert AFL 100 Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 28 Inverted Microscopes Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 29 Technical survey on the microscope stand configurations Microscope stand configuration Wilovert Code no. 018.0693.0 for brightfield and phase contrast Heavy U-shaped all cast body. Ergonomically placed coaxial coarse and fine focusing knobs. Height adjustment of the coarse drive 22 mm (total). Height adjustment of the fine drive: 2 µm per scale drive. Binocular observation tube 360° rotatable, 30° inclined. Interpupillary distance 55 mm - 75 mm adjustable. Diopter adjustment at both eyepiece tubes. Large, fixed microscope stage 210 mm x 235 mm Quintuple revolving nosepiece with ball bearing. Integrated in the microscope base is an halogen illumination 12 V / 30 W, continuously adjustable. Microscope stand configuration Wilovert AFL 018.0695.0 for incident fluorescence light, also in combination with brightfield and phase contrast Heavy U-shaped all cast body with integrated beam path for incident light illumination. Adapter for HBO- and halogen lamphouses. Ergonomically placed coaxial coarse and fine focusing knobs. Height adjustment of the coarse drive 22 mm (total). Height adjustment of the fine drive: 2 µm per scale drive. Binocular observation tube, 360° rotatable, 30° inclined. Interpupillary distance 55 mm - 75 mm adjustable. Diopter adjustment at each eyepiece tube. Large, fixed microscope stage 210 mm x 235 mm. Quintuple revolving nosepiece with ball bearing. Powerful supply for the 12 V / 30 W halogen illumination, continuously adjustable. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 30 Method of contrast: brightfield Wilovert Standard HF / K 008.0303.0 2.230 € up to objective 10 x consisting of: Microscope stand configuration Wilovert Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 lllumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Set of accessories WS Instruction for use Dust cover 018.0693.0 018.0033.0 019.9050.000 018.96634.1 018.96635 018.0628.0 018.96677 018.9550.0 901.1049.0 902.96670 Main focus of the application: Plancton, sediments, cell cultures, tissue cultures Method of contrast: brightfield Wilovert Standard HF 20 Code number Price 008.0309.0 2.385 € up to objective 20 x consisting of: Microscope stand configuration Wilovert Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective SPL 20 / 0,35 (LD) lllumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Set of accessories WS Instruction for use Dust cover Wilovert Standard PH 20 018.0693.0 018.0033.0 019.9050.000 018.96634.1 018.96635 018.96698 018.0628.0 018.96677 018.9550.0 901.1018.0 902.96670 008.0305.0 2.855 € 008.0304.0 3.545 € Same equipment as Wilovert Standard HF 20, but with phase contrast for objectives 10x and 20x and combi condenser NA 0,25 Wilovert Standard HF 40 up to objective 40 x consisting of: Microscope stand configuration Wilovert Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective SPL 20 / 0,35 (LD) Objective SPL 40 / 0,60 (LD) in correction mount lllumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Object guide (left hand control) Set of accessories WS Instruction for use Dust cover Wilovert Standard PH 40 018.0693.0 018.0033.0 019.9050.000 018.96634.1 018.96635 018.96698 019.0449.0 018.0628.0 018.96677 019.0079.0 018.9500.0 901.1018.0 902.96670 008.0306.0 4.015 € Same configuration as Wilovert Standard HF 40 but with phase contrast for objectives 10x, 20x, 40x, combi condenser NA 0,25 and object guide (left hand control) Holding frames for culture vessels: please see accessories Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 31 Main focus of the application: cell culture research, investigations in fluorescence Method of contrast: brightfield, incident fluorescence light Wilovert AFL 20 Code number Price 008.0307.0 6.650 € Up to objective 20 x consisting of: Microscope stand configuration AFL Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective SPL 20 / 0,35 (LD) Illumination unit HBO 100 Lamphouse HBO 100 with collector, mirror, lamp mount and heat protection filter Mercury high pressure lamp 100 W Power supply unit HBO 100 including mains cable Filterslider for up to 2 filtersets Filterset D for immunofluorescence (FITC) blue excitation Illumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Set of accessories WS AFL Instruction for use Dust cover 018.0695.0 018.0033.0 018.0425.0 018.96634.1 019.9052.000 018.96698 018.0314.0 662.0006.0 018.0504.0 018.0745.0 018.0454.0 018.0628.0 018.96677 018.9554.0 901.1044.0 902.96670 Holding frames for culture vessels: please see accessories Wilovert AFL 40 008.0308.0 7.820 € Up to objective 40 x consisting of: Microscope stand configuration AFL Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective SPL 20 / 0,35 (LD) Objective SPL 40 / 0,60 (LD) in correction mount Illumination unit HBO 100 Lamphouse HBO 100 with collector, mirror, lamp mount and heat protection filter Mercury high pressure lamp 100 W Power supply unit HBO 100 including mains cable Filterslider for up to 2 filtersets Filterset D for immunofluorescence (FITC) blue excitation Illumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Object guide (left hand control) Set of accessories WS AFL Instruction for use Dust cover 018.0695.0 018.0033.0 018.0425.0 018.96634.1 018.96635 018.96698 019.0449.0 018.0314.0 662.0006.0 018.0504.0 018.0745.0 018.0454.0 018.0628.0 018.96677 019.0079.0 018.9554.0 901.1044.0 902.96670 Holding frames for culture vessels: please see accessories Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 32 Method of contrast: brightfield, phase contrast, incident fluorescence light Wilovert AFL 20 Phako Code number Price 008.0300.0 7.170 € up to objective 20 x consisting of: Microscope stand configuration AFL Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A Ph 1 10 / 0,25 Objective SPL 20 / 0,35 (LD) Objective SPL Ph2 20 / 0,35 (LD) Filterslider for up to 2 filtersets Filterset for immunofluorescence FITC (blue excitation) Illumination unit 12 V / 30 W halogen Combination condenser NA 0,25 for brightfield and phase contrast Ph1/ 2 for attachment to the illumination unit Illumination unit HBO 100 Lamphouse HBO 100 with collector, mirror, lamp mount and heat protection filter Mercury high pressure lamp 100 W Power supply unit HBO 100 including mains cable Set of accessories WS AFL Instruction for use Dust cover Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope. 018.0695.0 018.0033.0 018.0425.0 018.96634.1 018.96657 018.96698 018.96699 018.0745.0 018.0454.0 018.0628.0 018.96673 018.0314.0 662.0006.0 018.0504.0 018.9554.0 901.1044.0 902.96670 018.96149 135 € 008.0301.0 8.350 € Method of contrast: brightfield, phase contrast and incident fluorescence Wilovert AFL 40 Phako up to objective 40 x consisting of: Microscope stand configuration AFL Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective AC 4 / 0,10 Objective A Ph 1 10 / 0,25 Objective SPL 20 / 0,35 (LD) Objective SPL Ph2 20 / 0,35 (LD) Objective SPL Ph2 40 / 0,60 (LD) in correction mount Combination condenser NA 0,25 for brightfield and phase contrast Ph1/ 2 for attachment to the illumination unit Illumination unit 12 V / 30 W halogen Filterslider for up to 2 filtersets Filterset for immunofluoresence FITC (blue excitation) Illumination unit HBO 100 Lamphouse HBO 100 with collector, mirror, lamp mount and heat protection filter Mercury high pressure lamp 100 W Power supply unit HBO 100 including mains cable Object guide (left hand control) Set of accessories WS AFL Instruction for use Dust cover 018.0695.0 018.0033.0 018.0425.0 018.96634.1 018.96657 018.96698 018.96699 019.0468.0 018.96673 018.0628.0 018.0745.0 018.0454.0 018.0314.0 662.0006.0 018.0504.0 019.0079.0 018.9554.0 901.1044.0 902.96670 Holding frames for culture vessels: please see accessories Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data 018.96149 135 € Issue April 2011 Page 33 Filtersets for Wilovert AFL Code number 018.0451.0 Price 815 € Filterset D (FITC) Excitation range 450 - 490 nm, dichroic mirror 510 nm, suppression filter 520 nm 018.0454.0 485 € Filterset E (TRITC) Excitation range 515 - 560 nm, dichroic mirror 580 nm, suppression filter 580 nm 018.0455.0 485 € Filterset G (Mykoval) Excitation range 355 - 425 nm, dichroic mirror 400 nm, suppression filter 455 nm 018.0442.0 485 € Filterset Texas Red Excitation range 540 - 580 nm dichroic mirror 595 nm, suppression filter 600 - 660 nm 018.0602.0 1.125 € Filterset Rhodamin (red version) Excitation range 546 nm, dichroic mirror 565 nm, suppression filter 600 - 660 nm 018.0603.0 1.125 € Filterset A (DAPI) Excitation range 340 - 380 nm, dichroic mirror 400 nm, suppression filter 435 - 485 nm Assembly of further filtersets (per filterset) 60 € Further filtersets upon request Filtersliders for fluorescence Filterslider for 2 filtersets 018.0745.0 365 € Filterslider for 4 filtersets 018.0746.0 550 € Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 34 Components for further upgrade of inverted microscopes Objectives Brightfield objectives Code number 018.96634.1 Price 52 € Achromatic objective A 10 / 0,25 Free working distance 7,0 mm 018.96635 72 € Semiplan achromatic objective SPL 20 / 0,35 (LD) Free working distance 4,0 mm 018.96698 175 € Semiplan achromatic objective SPL 40 / 0,60 (LD) with correction mount Free working distance 4,7 mm, correction range 0,6 - 1,6 mm 019.0449.0 550 € Achromatic objective A Ph1 10 / 0,25 Free working distance 7,0 mm 018.96657 155 € Semiplan achromatic objective SPL Ph2 20 / 0,35 (LD) Free working distance 4,0 mm 018.96699 260 € Semiplan achromatic objective SPL Ph2 40 / 0,60 (LD) with correction mount Free working distance 4,7 mm, correction range 0,6 - 1,6 mm 019.0468.0 610 € 018.96677 125 € 018.96673 290 € 018.96693 310 € 019.0079.0 610 € 018.96691 018.96678 018.96679 018.96680 018.96681 018.96853 018.96682 018.96683 018.96684 018.96685 018.96686 018.96687 018.96688 018.96689 018.96690 018.96890 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € Achromatic objective A 4 / 0,10 Free working distance 18 mm Phase contrast objectives Condensers Brightfield condensers Brightfield condenser NA 0,25 for adaptation to the illumination unit Combination condensers Combination condensers for brightfield and phase contrast Combination condenser NA 0,25 for adaptation to the illumination unit. For brightfield objectives 4/10/20/40 and phase contrast objectives Ph1/2 10/20. Combination condenser NA 0,40 for adaptation to the illumination unit. For brightfield objectives 4/10/20/40 and phase contrast objective PH 1/2 10/20/40. Object guide Object guide for holding frames, left hand control Holding frame for culture vessels 2 brackets for roller bottles for stage 210 x 235 mm Holding frame Terasaki for 60/72/120 well trays Holding frame for vessels with 96 well trays / multiwell plates Holding frame for Hamax with 60 well trays Holding frame for Petri dishes, diameter 36 mm Holding frame for Petri dishes, diameter 42 mm Holding frame for Petri dishes, diameter 54 mm Holding frame for Petri dishes, diameter 65 mm Holding frame for Petri dishes, diameter 88 mm Holding frame for Costar vessels Holding frame for Corning vessels Holding frame for object guides 76 x 26 mm (3x1 inch), with specimen clips Holding frame for Costar with 24 sample fields, round Holding frame for Costar vessels with 24 sample fields, (squares) Holding frame for Greiner + Falcon vessels Holding frame for plankton chambers, diameter 43 mm Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 35 Components for further upgrade of inverted microscopes Eyepieces Code number 018.0425.0 Price 21 € 018.96792 105 € 019.9037.000 41 € Widefield eyepiece WF 12,5/18 018.96284 185 € Widefield eyepiece WF 12,5x/18 B also suitable for spectacle wearers with eyeguards 018.96794 210 € Widefield eyepiece WF 10x/18 Widefield eyepiece WF 10x/18 B also suitable for spectacle wearers with eyeguards Widefield eyepiece WF 10x/20 with field of view 20 also suitable for spectacle wearers Pointing, measuring, counting and calibration with graticules Measuring eyepieces differ from normal eyepieces in their construction. Therefore they cannot be used combined with normal eyepieces. For observation with two eyes a second measuring eyepiece without graticule, used as a complement eyepiece, is necessary . Pointing Code number Price 018.0712.0 105 € 018.96226 82 € 018.0478.001 240 € 018.0478.0 210 € Micrometer eyepiece WF10x / 18 with cross hair contains graticule 059.0032.0 Complement eyepiece WF 10 x / 18 018.0478.002 240 € 018.0478.0 210 € Micrometer eyepiece WF10x / 18 10 mm = 100 divisions contains graticule 059.14054 Complement eyepiece WF 10 x / 18 018.0478.003 240 € 018.0478.0 210 € 018.0478.005 260 € 018.0478.0 210 € 018.0478.004 405 € 018.0478.0 210 € Stage micrometer for transmitted light 1 mm = 100 divisions 2 mm = 200 divisions 019.96133 019.96723 93 € 105 € Stage micrometer for incident light 1 mm = 100 divisions 019.96843 93 € WF 10 x / 18 with pointer contains pointer 503.0226.0 Complement eyepiece WF 10 x / 18 (for SPL and PL-objectives) Cross hair eyepiece WF 10x / 18 contains graticule 059.14053 Complement eyepiece WF 10 x / 18 Measuring Components for further upgrade of inverted microscopes Counting Counting eyepiece WF 10x 10 x 10 lines; 10 mm x 10 mm contains graticule 059.14057 Complement eyepiece WF 10 x 20x3 10x3 5x5/ Eyepiece WF 10x G 22 Walton and Beckett contains graticule 059.0108.0 Complement eyepiece WF 10 x 5 7 9 Calibration Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 36 Components for further upgrade of inverted microscopes Tubes Code number Price Binocular tube C inclined 30°, TF=1x 019.0558.0 210 € Binocular tube H inclined 30°, TF=1x 018.0033.0 405 € 018.0467.0 1.515 € 902.0079.0 15 € Trinocular phototube 30 / 70 inclined 30°, TF=1x, beam splitting 30% visual / 70% documentation (fixed) 018.0034.0 610 € Trinocular phototube 100 / 100 inclined 30°, TF=1x, beam splitting 100% visual / 100% documentation (changeable) 019.0505.0 875 € 018.0810.0 215 € Video-adapter without intermediate optics (1x) (C-Mount) for trinocular phototubes 019.0094.0 93 € Video-adapter with intermediate optics 0,5x (C-Mount) for trinocular phototubes 019.0453.0 105 € Video-adapter with intermediate optics 1,6x (C-Mount) for trinocular phototubes 019.0442.0 175 € For education of a second observer Discussion bridge DB 2 for a second observer with pointer, that can be operated by both observers Dust cover for discussion bridge The discussion bridge can be adapted to all professional laboratory microscopes. For information please contact our technical service. Observation tubes and eyepieces are to be ordered separately, since these are not contained in the discussion bridge. Trinocular tubes Tubes for adaptation of photo- or video equipment Equipment for photomicrography Prerequisite: Tube for adaptation of photo- respectively video equipment For adaptation of SLR cameras Adapter set for Canon SLR cameras incl. Photo eyepiece T 2 adapter for adaptation of other SLR-cameras to phototubes upon request. Adaptation of video- and photosystems in combination with trinocular phototube 018.0034.0 / 019.0505.0 or replacement tube For adaptation of photo equipment please contact our technical service. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 37 Components for further upgrade of inverted microscopes Heating stage Code number Price 018.0662.0 505 € 018.0655.0 330 € 018.0664.0 540 € 018.96747 018.96748 41 € 31 € 018.0459.0 125 € Immersion oil nD 1,515 PCB-free, 10 ml 902.0066.0 15 € Faxo-Clean cleaning liquid 30 ml 902.0065.0 8€ 019.9999.132 41 € Set of accessories WS Mains cable with safety plug 1 halogen lamp 12 V / 30 W (spare) 2 spare fuses 230 V, 0,2 ATR Green filter VG 9 in slip-on mount for the condenser Allen key, SW 4 mm, chromed Code number 018.9550.0 625.56362 662.0009.0 018.0369.0 018.96747 902.0084.0 Price 66,50 € 10,20 € 13,00 € 3,50 € 35,80 € 4,00 € Set of accessories WS AFL Mains cable with safety plug 1 halogen lamp 12 V / 30 W (spare) 2 spare fuses 230 V, 0,2 ATR Tube for adjustment Protective glasses Protective gloves Allen key, SW 4 mm, chromed Allen key SW 3 mm Green filter VG 9 in slip-on mount for the condenser 2 centering keys SW 1,5 x 45 Eyeguards 018.9554.0 625.56362 662.0009.0 018.0369.0 018.0598.0 599.0016.0 599.0017.0 902.0084.0 902.96851 018.96747 019.0120.0 902.97300 148,30 € 10,20 € 13,00 € 3,50 € 41,70 € 15,50 € 10,30 € 4,00 € 3,00 € 35,80 € 5,20 € 6,10 € Small heating stage HT up to 50° C for Wilovert, integrated in the Wilovert stage plate (including plug in unit 12 V / 30 W) Control unit for HT 50 (including plug in unit Input 100 V-240 V AC / 0,4 A Output 12 V DC / 1,25 A) Warming plate (including plug in unit 12 V / 30 W) Lightfilters for adaptation to the condenser, that is attached to the illumination unit Greenfilter VG 9 in slip-on mount for condenser Conversion filter (day light filter) in slip-on mount for condenser Polarisation Polarisation equipment for Wilovert Immersion oil and cleaning liquids Optical cleaning set, consisting of: Cleaning liquid 30 ml Anti-static cleaning cloth Anti-static brush Grabber stick for absorbing dust particles Components for further upgrade of inverted microscopes Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 38 Halogen lamps Halogen lamp 6 V / 10 W socket G4 Single Set (6 pieces) Code number 662.96236 018.96277 Price 9€ 46 € 662.0003.0 018.96891 11 € 57 € 662.0009.0 13 € Code number 662.96229 Price 18 € 662.0005.0 18 € 662.96290 185 € 662.0006.0 210 € Suitable for: - V 300/C 300 until production date 11.99 / serial number 1008600 - BX 300 - Stereomicroscope stands SM-AD - Wilovert A until production date end 86 / serial number 200850 - S 200 Halogen lamp 6 V / 20 W socket G4 Single Set (6 pieces) Suitable for: - H 500 until 10.99 / 1008500 - V 300 / C 300 from 12.99 / 1008900 - Wilovert until 10.99 / 1008400 Halogen lamp 12 V / 30 W socket G4 Suitable for: - Wilovert from 1.2000 / 1008600 - H 600 Components for further upgrade of inverted microscopes Halogen lamp 12 V / 50 W socket G 5,3 / 6,35 Suitable for : - H 600 LL incident light illuminator AM, (at H 600 and WAD), Metallovert, Wilovert LL Halogen lamp 12 V / 100 W socket G 6,35 Suitable for: - H 600 LL, Wilovert LL, incident light illuminator AM (at H 600 and WAD), Wilovert LL Mercury high pressure lamps Hg-mercury high pressure lamp 50 W Suitable for: - H 500 AFL 50, H 600 AFL 50, Wilovert AFL 50 Hg-mercury high pressure lamp 100 W Suitable for: - H 500 AFL 100, H 600 AFL 100, Wilovert AFL 100 Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 39 Incident light microscopy and workshop microscopes Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 40 Technical survey on the microscope stand configurations Incident light microscopes series H 600 Code no. Solid, heavy cast-metal stand, rectangular shape for high expandability. Maximal stability guarantees smooth microscopy. Coaxial coarse and fine focusing. Height adjustment of the coarse drive 22 mm (total). Height adjustment of the fine drive 2 µm per scale division. Binocular observation tube 360° rotatable, inclination 30°, tube factor 1x. Interpupillary distance 55 mm - 75 mm adjustable at each observation tube. Quadruple nosepiece - quintuple nosepiece available as option. Mechanical stage 160 mm x 130 mm with ergonomically placed coaxial knobs. Adjustment range 76 mm x 52 mm The following microscope stand configurations are available: Microscope stand configuration H 600 /12-4 for incident and transmitted light with condenser height adjustment. Sophisticated illumination tube with centerable field diaphragm. Condenser height adjustment for exact illumination according to Köhler. 018.0649.0 Microscope stand configuration H 600 / 4 with lowerable stage, so that for example polished sections of 50 mm height can be examined. 018.0438.0 Microscope stand configuration W-AD for quality control and production surveillance Stand for incident and transmitted light with column Maximal object height 180 mm Microscope stage 170 x 150 mm Microscope body with thoothed gear Coaxial coarse and fine focus Quadrupe revolving nosepiece Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 41 Main focus of the application: metallurgy, quality control of workpieces Method of contrast: Incident light brightfield H 600 AM 50 consisting of: Microscope stand configuration H 600/12-4 with lowerable stage Binocular tube (30°TF 1x) Eyepiece WF 10x / 18 2x Objective EPI A 4 / 0,13 Objective EPI A 10 / 0,30 Objective EPI A 20 / 0,50 Objective EPI A 40 / 0,60 Compact incident light illuminator AM with field diaphragm, aperture diaphragm and filterslider Halogen illumination 12 V / 50 W consisting of: Lamphouse HAL 50 with collector, rear mirror, lamp mount and heat protection filter Power supply for halogen lamp 12 V / 50 W, halogen lamp 12 V / 50 W Set of accessories H Instruction for use Dust cover Code number Price 008.0223.0 3.595 € 018.0438.0 018.0033.0 018.96226 019.0519.0 019.0520.0 019.0521.0 019.0522.0 018.0783.0 018.0323.0 019.9016.0 901.1079.0 902.96670 Method of contrast: Incident light brightfield, transmitted light brightfield H 600 AM AL/DL 50 008.0288.0 consisting of: Microscope stand configuration H 600 /12-4 with lowerable stage Binocular tube (30°TF 1x) Eyepiece WF 10x / 18 2x Objective EPI A 4 / 0,13 Objective EPI A 10 / 0,30 Objective EPI A 20 / 0,50 Objective EPI A 40 / 0,60 Condenser NA 0,9 Compact incident light illuminator AM with field diaphragm, aperture diaphragm and filterslider Halogen illumination 12 V / 50 W consisting of: Lamphouse HAL 50 with collector, rear mirror, lamp mount and heat protection filter Power supply for halogen lamp 12 V / 50 W, halogen lamp 12 V / 50 W Set of accessories H Instruction for use Dust cover Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data 3.925 € 018.0649.0 018.0033.0 018.96226 019.0519.0 019.0520.0 019.0521.0 019.0522.0 018.0028.0 018.0783.0 018.0323.0 018.9011.0 901.1079.0 902.96670 Issue April 2011 Page 42 Workshop microscope Main focus of the application: quality control and production surveillance W-AD 50 consisting of: Microscope stand configuration W-AD Microscope body with gear drive Binocular tube (30°TF 1x) Eyepiece WF 10x / 18 2 Stück Objective EPI A 4 / 0,13 Objective EPI A 10 / 0,30 Objective EPI A 20 / 0,50 Objective EPI A 40 / 0,60 Incident light illuminator AM with field diaphragm, aperture diaphragm and filterslider Fibre light source FLQ M Flexible light guide 1,5 m length Opal disc Set of accessories W-AD Instruction for use Dust cover Set of accessories W-AD Mains cable with safety plug 1 spare fuse 1 spare bulb 6 V / 10 W Code number Price 008.0415.0 3.790 € 018.0398.0 018.0355.0 018.0033.0 018.96226 019.0519.0 019.0520.0 019.0521.0 019.0522.0 018.0783.0 003.0040.0 060.0177.027 059.10976 018.9700.0 901.1037.0 902.96670 018.9700.0 625.56362 018.0612.0 662.96236 22,70 € 10,20 € 3,50 € 9,00 € 019.96852 550 € Adjustment range = 50 mm/resolution = 0,01 mm 019.96838 240 € Adjustment range = 50 mm/resolution = 0,005 mm 019.96839 250 € Holding device for x-direction, diameter 12 mm 019.0185.0 41 € Holding device for y-direction, diameter 12 mm 019.0186.0 41 € Adjustment range = 50 mm/resolution = 0,001 mm 019.96840 1.230 € Holding device for x-direction, diameter 18 mm 019.0188.0 52 € Holding device for y-direction, diameter 18 mm 019.0189.0 52 € Measuring stages for workshop microscope W-AD Coordinate plane table, adjustment range 50 x 50 mm (can only be mounted in the factory) At this stage the following micrometer spindles can be adapted: Micrometer spindle with drum reading adaptable to the coordinate stage Micrometer spindles with digital display adaptable to the coordinate stage Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 43 Components for further upgrade of incident light microscopes Achromatic incident light objectives EPI A Achromatically corrected objectives, for use without cover glasses. EPI A 4/0,13 free working distance 11,657 Code number 019.0519.0 Price 52 € EPI A 10/0,30 free working distance 6,742 019.0520.0 82 € EPI A 20/0,50 free working distance 0,838 019.0521.0 145 € EPI A 40/0,65 spring loaded free working distance 0,467 019.0522.0 155 € EPIA 60/0,75 spring loaded free working distance 0,58 mm 019.9201.000 395 € Widefield eyepiece WF 10x/18 018.0425.0 21 € Widefield eyepiece WF 10x/18 B also suitable for spectacle wearers with eyeguards 018.96792 105 € 019.9037.000 41 € Widefield eyepiece WF 12,5/18 018.96284 185 € Widefield eyepiece WF 12,5x/18 B also suitable for spectacle wearers with eyeguards 018.96794 210 € Recommended eyepiece 018.96226 Eyepieces Widefield eyepiece WF 10x/20 with field of view 20 also suitable for spectacle wearers Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 44 Pointing, measuring, counting and calibration with graticules Measuring eyepieces differ from normal eyepieces in their construction. Therefore they cannot be used combined with normal eyepieces. For observation with two eyes a second measuring eyepiece without graticule, used as a complement eyepiece, is necessary. Pointing WF 10 x / 18 with pointer contains pointer 503.0226.0 Complement eyepiece WF 10 x / 18 (for SPL and PL-objectives) 018.0712.0 105 € 018.96226 82 € 018.0478.001 240 € 018.0478.0 210 € Code number 018.0478.002 Price 240 € 018.0478.0 210 € 018.0478.003 240 € 018.0478.0 210 € 018.0478.005 260 € 018.0478.0 210 € 018.0478.004 405 € 018.0478.0 210 € Stage micrometer for transmitted light 1 mm = 100 divisions 2 mm = 200 divisions 019.96133 019.96723 93 € 105 € Stage micrometer for incident light 1 mm = 100 divisions 019.96843 93 € Cross hair eyepiece WF 10x / 18 contains graticule 059.14053 Complement eyepiece WF 10 x / 18 Components for further upgrade of incident light microscopes Measuring Micrometer eyepiece WF10x / 18 with cross hair contains graticule 059.0032.0 Complement eyepiece WF 10 x / 18 Micrometer eyepiece WF10x / 18 10 mm = 100 divisions contains graticule 059.14054 Complement eyepiece WF 10 x / 18 Counting Counting eyepiece WF 10x 10 x 10 lines; 10 mm x 10 mm contains graticule 059.14057 Complement eyepiece WF 10 x Eyepiece WF 10x G 22 Walton and Beckett contains graticule 059.0108.0 Complement eyepiece WF 10 x 20x3 10x3 5x5/ 5 7 9 Eyepieces shown above are also avialable at 12,5x magnification Calibration Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 45 Components for further upgrade of incident light microscopes Tubes Binocular tube C inclined 30°, TF=1x Code number 019.0558.0 Price 210 € Binocular tube H inclined 30°, TF=1x 018.0033.0 405 € 018.0467.0 1.515 € 902.0079.0 15 € Trinocular phototube 30 / 70 inclined 30°, TF=1x, beam splitting 30% visual / 70% documentation (fixed) 018.0034.0 610 € Trinocular phototube 100 / 100 inclined 30°, TF=1x, beam splitting 100% visual / 100% documentation (changeable) 019.0505.0 875 € 018.0810.0 215 € Video-adapter without intermediate optics (1x) (C-Mount) for trinocular phototubes 019.0094.0 93 € Video-adapter with intermediate optics 0,5x (C-Mount) for trinocular phototubes 019.0453.0 103 € Video-adapter with intermediate optics 1,6x (C-Mount) for trinocular phototubes 019.0442.0 175 € 662.96229 18 € 662.0005.0 18 € For education of a second observer Discussion bridge DB 2 for a second observer with pointer, that can be operated by both observers Dust cover for discussion bridge Observation tubes and eyepieces are to be ordered separately, since these are not contained in the discussion bridge. Trinocular tubes Tubes for adaptation of photo- or video equipment Equipment for photomicrography Prerequisite: Tube for adaptation of photo- respectively video equipment For adaptation of SLR cameras Adapter set for Canon SLR cameras incl. Photo eyepiece T 2 adapter for adaptation of other SLR-cameras to phototubes upon request. Adaptation of video- and photosystems in combination with trinocular phototube 018.0034.0 / 019.0505.0 or replacement tube For adaptation of photo equipment please contact our technical service. Spare lamps Halogen lamp 12 V / 50 W socket G 5,3 / 6,35 Suitable for: - H 600 LL incident light illuminator AM, (at H 600 and WAD), Metallovert Halogen lamp 12 V / 100 W socket G 6,35 Suitable for: - H 600 LL, Wilovert LL, incident light illuminator AM (at H 600 and WAD) Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 46 Stereomicroscopes Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 47 Complete stereomicroscope configurations Stereomicroscope Wiloskop - F Zoom with stand ST 008.0402.0 910 € 008.0403.0 1.090 € without illumination Trinocular zoom body Greenough system Magnification range: 6,7x - 45x, with eyepieces WF 10 x / 22 Diopter adjustment: individually at both eyepiece tubes Rack-and-pinion focusing drive with tension adjustment Black-and-white stage plate, 2 stage clips Illumination/Method of contrast: Illumination via external light sources, as described in the paragraph: Light sources for stereomicroscopes Stereomicroscope Wiloskop - F Zoom with stand ST - AD LED with LED incident and transmitted light illumination Trinocular zoom body Greenough system Magnification range: 6,7x - 45x, with eyepieces WF 10 x / 22 Diopter adjustment: individually at both eyepiece tubes Rack-and-pinion focusing drive with tension adjustment Black-and-white stage plate, 2 stage clips Illumination/Contrasting method: Incident light-brightfield: LED array approx. 2W brightness. The lamp is rotatable and the brightness is continuously adjustable. Transmitted light-brightfield: LED array approx. 2W brightness. The lamp is rotatable and the brightness is continuously adjustable. Low-voltage wall power supply Stereomicroscope Wiloskop - F Zoom with stand ST - S 008.0404.0 970 € POL unit for Wiloskop 019.9999.142 250 € LED ringlight 019.9999.156 380 € Control unit for LED ringlight 019.9999.155 430 € Foot for LED spot 019.9999.157 90 € Goose nack illumination 019.9999.158 60 € LED spot white 019.9999.159 195 € LED spot warm white 019.9999.160 195 € Diffuser for LED spot 019.9999.161 40 € 503.0938.0 45 € 019.9999.172 335 € without illumination Trinocular zoom body Greenough system Magnification range: 6,7x - 45x, with eyepieces WF 10 x / 22 Diopter adjustment: individually at both eyepiece tubes Heavy cast-metal, circular base Rack-and-pinion focusing drive with tension adjustment Illumination/Method of contrast: Illumination via external light sources, as described in the paragraph: Light sources for stereomicroscopes Accessories for Stereo Microscopes Adapator ring for LED ringlight Micrometer calibration scale On object carrier 76 mm x 50 mm with division 0,1 mm mand 2" resp. 0,005" division in wodden case Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 48 Stereomicroscope head SK Wiloskop - F Zoom 019.9101.000 750 € Eyepieces WF 15 x / 16 (pair) WF 20 x / 12 (pair) 019.9105.000 019.9105.001 70 € 70 € Measuring Eyepiece WF 10 x / 22r with micrometer scale (10 mm in 100 divisions) 019.9105.002 100 € Eyeguards 1 pair 019.9105.003 10 € Auxiliary lenses 0,3 x 0,5 x 1,5 x 2,0 x 019.9104.000 019.9104.001 019.9104.002 019.9104.003 90 € 90 € 90 € 90 € 018.0857.0 018.0858.0 150 € 130 € 019.9103.001 019.9999.092 80 € 37 € 019.9102.000 160 € 019.9102.001 340 € Trinocular zoom body Greenough system Magnification range: 6,7x - 45x, with eyepieces WF 10 x / 22 Diopter adjustment: individually at both eyepiece tubes Accessories for Stereomicroscope head SK Wiloskop - F Zoom Adaptation of C-Mount-Cameras Adapter for C-Mount-Cameras 0,5 x Adapter for C-Mount-Cameras 1,0 x Adaptation of digital SLR-Cameras Phototube for D-SLR with photo eyepiece 4x (a specific T2-Adapter is needed) T2-Adapter for Canon D-SLR Stereo microscope stands Microscope Stand ST without illumination Rack-and-pinion focusing drive with tension adjustment Black-and-white stage plate, 2 stage clips Illumination/Method of contrast: Illumination via external light sources, as described in the paragraph: Light sources for stereomicroscopes Incident Transmitted Light - Microscope Stand ST - AD LED Rack-and-pinion focusing drive with tension adjustment Black-and-white stage plate, 2 stage clips Illumination/Contrasting method: Incident light-brightfield: LED array approx. 2W brightness. The lamp is rotatable and the brightness is continuously adjustable. Transmitted light-brightfield: LED array approx. 2W brightness. The lamp is rotatable and the brightness is continuously adjustable. Low-voltage wall power supply Microscope Stand ST - S boom stand - without illumination 019.9102.002 220 € 902.0052.0 902.96096 018.96189 10 € 10 € 3€ Heavy cast-metal, circular base Rack-and-pinion focusing drive with tension adjustment Illumination/Method of contrast: Illumination via external light sources, as described in the paragraph: Light sources for stereomicroscopes Accessories for stereomicroscopes Dust cover for stereomicroscopes with stand ST and ST - AD LED Dust cover for stereomicroscopes with stand ST - S Specimen holder (1 piece) Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 49 External lightsources for stereomicroscopes Cold light sources Code number Price 003.0023.000 003.0022.000 420 € 420 € 662.0002.0 21 € Goose neck lightguide Number of the arms: 1 Length: 65 cm Diameter active: 4 mm 060.0102.027 93 € Goose neck lightguide Number of the arms: 2 Length: 65 cm Diameter active: 4 mm 060.0100.027 165 € Goose neck lightguide Number of the arms: 3 Length: 65 cm Diameter active: 4 mm 060.0114.027 220 € Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 3 mm Adapter necessary 060.0155.027 93 € 500.0011.0 21 € Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 8 mm Adapter necessary 060.0184.027 125 € 500.0013.0 21 € Ringlight Number of the lightpoints: 4 Adapterring 060.0805.027 250 € 503.0890.0 41 € Ringlight Number of the lightpoints: 8 Adapterring 060.0806.027 365 € 503.0890.0 41 € Ringlight Number of the lightpoints: continuous ring Adapterring 060.1042.027 415 € 503.0890.0 41 € Cold light source FLQ 85 E / M Operating voltage: 110 V - 115 V / AC Operating voltage: 220 V - 230 V / AC upon request also available in 100 V, 200 V, 240 V Frequency: 50 / 60 Hz Power consumption: 120 W Electrical connection: Safety plug, safety class 1 Fuse: 0,8 A for 200 V-240 V, 1,6 AT for 100 V-110 V Lamp: Mirror lamp 3,8 V / 85 W Lifetime: approx. 1000 hours Optic: 3-lens condenser with heat protection filter Colour temperature: 3200° K at full power Dimensions: 112 mm (H) x 125 mm (B) x 255 mm (D) Weight: approx. 3,2 kg Housing: aluminium, steel plate Brightness control: electronically / optomechanically Certification: CE Accessories: Mirror lamp 13,8 V / 85 W (spare) Lightguides Further lightguides upon request. Production of customized lightguides possible. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 50 Cold light source FLQ 150 M Code number Price 003.0041.000 003.0040.000 490 € 490 € 662.0004.0 21 € Goose neck lightguide Number of the arms: 1 Length: 50 cm Diameter active: 4 mm 060.0966.027 82 € Goose neck lightguide Number of the arms: 2 Length: 50 cm Diameter active: 4 mm 060.0967.027 145 € Goose neck lightguide Number of the arms: 3 Length: 50 cm Diameter active: 4 mm 060.0968.027 230 € Ringlight Number of the lightpoints: 4 Length: 100 cm Inner diameter : 58 cm Adapterring 060.1045.027 250 € 503.0890.0 41 € Ringlight Number of the lightpoints: 8 Length: 100 cm Inner diameter : 58 cm Adapterring 060.1041.027 365 € 503.0890.0 41 € Ringlight Number of the lightpoints: continuous lightring 060.0823.027 415 € 503.0890.0 41 € Focusing set I consisting of 1 focusing set and 1 adaptersleeve 003.0040.012 62 € Focusing set II consisting of 2 focusing sets and 2 adaptersleeves 003.0040.009 82 € Colour filterset I consisting of: 1 yellow filter, 1 green filter, 1 red filter, 1 blue filter and 1 adaptersleeve Focusing set I necessary 003.0040.014 82 € 003.0040.012 62 € Colour filterset II consisting of: 2 yellow filters, 2 green filters, 2 red filters, 2 blue filters and 2 adaptersleeves Focusing set II necessary 003.0040.011 145 € 003.0040.009 82 € Operating voltage: 110 V - 115 V / AC Operating voltage: 220 V - 230 V / AC upon request also available in 100 V, 200 V, 240 V Frequency: 50 / 60 Hz Power consumption: 160 W Electrical connection: Safety plug, safety class 1 Fuse: 0,8 A for 200 V-240 V, 1,6 AT for 100 V-110 V Lamp: mirror lamp 15 V / 150 W Lifetime: approx. 1000 hours Optic: 1 lens condenser with heat protection filter Colour temperature: 3200° K at full power Dimensions: 120 mm (H) x 150 mm (B) x 280 mm (D) Weight: approx. 3,5 kg Housing: plastic Brightness contorl: optomechanically Certification: CE Accessories: Mirror lamp 15 V / 150 W (spare) Lightguides Adapterring Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 51 Code number 003.0040.013 Price 105 € Polarising set II consisting of 2 focusing lenses, 2 adaptersleeves and 2 polarising filters 003.0040.010 200 € Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 3 mm Adapter 060.0155.027 93 € 013.6006.0 21 € Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 6 mm Adapter 060.0175.027 115 € 013.6003.0 21 € Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 8 mm Adapter 060.0184.027 125 € 013.6004.0 21 € Polarising set I consisting of 1 focusing lens, 1 adaptersleeve and polarising filter Further lightguides upon request. Production of customized lightguides possible. Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 52 Cameras Digital USB-Cameras Code number 019.9999.167 Price 750 € CMOS-Kamera UI-1240 SE 1/1,8" Chip, colour 1,3 MP resolution, 25 fps C-Mount connection IDS uEye Software (for Windows XP/Vista/7) USB-cable included 019.9999.175 930 € CCD-Camara UI-2250 SE 1/2" chip, colour 2,0 MP resolution, 12 fps C-Mount connection IDS uEye Software (for Windows XP/Vista/7) USB-cable included 019.9999.169 1.890 € CCD-Camera UI-2280 SE 2/3" chip, colour 5,0 MP resolution, 6 fps C-Mount connection IDS uEye Software (for Windows XP/Vista/7) USB-cable included 019.9999.171 2.750 € 019.9999. 175 890 € CMOS-Camera UI-1465 LE 1/2" Chip, colour 3,1 MP resolution, 11fps C-Mount connection IDS uEye Software (for Windows XP/Vista/7) USB-cable included Digital SLR-Cameras Canon 550D DSLR Kit with EF-S 18-55mm 1:3,5-5,6 IS lens (image stabilized) 18,0-megapixel Canon APS-C CMOS sensor Full-HD Video with variable frame rate Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail: [email protected] Subject to change without notice Right reserved to modify technical data Issue April 2011 Page 53