Transcript
Price List Microscopy
Upright Microscopes Inverted Microscopes Incident Light and Workshop Microscopes Stereomicroscopes Digital Cameras
Issue July 2011
Quality „Made in Germany“
Your contact partners:
Distributor support Werner Kampe Sales and Marketing Manager Phone: +49 (06441) 2004-60 e-mail:
[email protected]
Customer & quotation service national, order processing Petra Hertstein-Hecker Sales Assistant Phone: +49 (06441) 2004-26 e-mail:
[email protected]
Service, spare parts and repairs Michael Wagner Head of service department and technical support Phone: +49 (06441) 2004-51 e-mail:
[email protected]
Customer & quotation service international, order processing Susanne Bartel Sales Assistant Phone: +49 (06441) 2004-24 e-mail:
[email protected]
Technical & application advice Dr. Jörg Haus Product Manager Phone: +49 (06441) 2004-28 e-mail:
[email protected]
Helmut Hund GmbH Wilhelm-Will-Strasse 7 D-35580 Wetzlar Fax 06441 2004-44 Tel. 06441 2004-0 E-Mail:
[email protected] Internet: www.hund.de
Important Information for our business partners and customers This pricelist supersedes all previous versions. Our general terms and conditions are applicable. They are available for download at our website www.hund.de. Terms of delivery to destinations outside Germany are ex factory Wetzlar.
Information regarding Medical Device Law and Certifications Microscopes are so-called In-vitro-diagnostic instruments according to the Medical Device Law (MPG § 3 / 4) if they are used for the investigation of specimen derived from the human body. Products must be used in compliance with the purpose of the device as it is defined by the manufacturer. According to the Medical Device Operator Ordinance (MPBetreibV § 2 / 5) the user has to assure himself - before setting the medical device in use - of the functionality and the proper condition of the medical device. In addition, the user has to read the operating instructions and has to follow the attached security and maintenance advices as well. The configuration delivered contains means which enable the user to adjust the microscope properly (according to Köhler) and to adjust special configurations such as phase contrast and darkfield in a proper way. The user is therefore in a position to prove the proper condition of his Hund-microscope in case adequate certifications of his laboratory will be carried out.
Tests • • • •
Protective conductor test acc. to EN-61010, Test current 25 A, Threshold 0,1 Ohm High voltage test acc. to EN-61010, Test voltage 1350 V AC Leakage current test acc. to EN-61010, Measurement set-up A2 Test voltage 230 V AC, Threshold 0,7 mA with 2 kOhm
EG-Declaration of Conformity - CE-mark The instrument matches the EG-Directive 98/79/EWG-IVD, the directive 73/23/EWG - low voltage directive - and the directive 89/336/EWG concerning the electromagnetic compatibility. We are certified according to DIN EN ISO 9001:2000 (quality management) and DIN EN ISO 14 001 (environmental management) and are validated according to EG-Regulation 761/2001 (Öko-Audit).
Warranty The warranty on microscopes as well as on optical and mechanical components is 2 years after transfer of perils and 1 year for cameras and other electronic products. Lamps, fuses and consumables are not included in the warranty. During these 2 years warranty damages will be handled free of charge in our factory in Wetzlar. This warranty does not cover damages caused through outside influences or inappropriate handling. The freight charges have to be borne by both parties. Each party will bear 50 % of the freight and handling charges. Furthermore we offer for a period up to 20 years professional repairs and supply of spare parts for mechanical and optical components. Availability needs to be clarified per individual case. Claims should be reported immediately and in written form not later than 8 days after receipt of the goods.
Maintenance and repairs Servicing and repairs will be carried out for microscopes of the brands Hund or Will only. Spare parts and transportation cost will be charged separately. Repair cost will be charged according to the actual working hours occurring for the individual repair. Our quotations on repairs are not binding, since hidden damages can only be detected during the process of maintenance and repair. We will charge a diagnostic lump sum of EUR 50,00 for checking the instrument and for calculating the precise repair costs. These costs for a diagnosis will not be charged in case of a repair order. For the maintenance and repair of larger numbers of microscopes (for example in schools or universities) we provide the possibility of an on-site inspection. For the repair of single units of microscopes, we recommend to carry out the repair work in our factory to optimise cost. Our repair and service invoices are quoted plus V.A.T. (according to the current rates) and are payable without cash discount. The warranty period for claims of damages on repairs is 6 months counting from transfer of perils. In the case of a repair no new warranty period for claims of damages is starting. Starting date is the purchase of the customer and the assignment of the repair. Microscopes are optical precision instruments. In case of return to our premises for maintenance or repair it is recommended to utilise the original or an equivalent packaging.
Upright microscopes Product
page
Overview on the microscope stand configurations
4
Microscopes for education
6
Microscopes for medical practitioners - haematology
7
Microscopes for medical practitioners and hospitals - haematology - urology
8
Microscopes for central laboratories and hospitals - haematology - urology - gynaecology - dermatology
9
Configurations for pathology
10
Configurations for bacteriology
11
Equipment for immunology
13
Filtersets for H 600 AFL
13
Microscopes for heating stage - native specimen - fertility investigations
14
Fluorescence microscopes with LED-illumination
15
Configurations for investigations of native blood in darkfield
17
Equipment for investigation of microorganisms in liquids - breweries - sewage treatment plants
17
Polarising microscopes
18
Polarising microscopy - components
19
Components for upgrading of upright microscopes - objectives - condensers and accessories - eyepieces - pointing, measuring and counting with graticules - tubes - discussion tube - trinocular tubes - adaptation of video and photo accessories - LED-fluorescence-illuminators - attachable mirrors - immersion oil and cleaning liquids - specimen holder - storage and transportation - heating stages - accessory sets - halogen lamps, spare bulbs, mercury high pressure lamps
20 22 22 23 24 24 24 24 24 25 25 25 25 25 25 27
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 1
Inverted microscopes Product
page
Overview on the microscope stand configurations
30
Inverted microscopes for botany, cell culture laboratories, cell biology / fluorescence - plancton - dreissena-larvae - rotatories/ciliates - sediments - cell culture - tissue cultures
31
Filtersets for Wilovert AFL
34
Components for upgrading the inverted microscopes - objectives - condensers and accessories - object guide - holding frames - eyepieces - pointing, measuering, counting and calibartion with graticules - tubes - discussion tube - trinocular tubes - adaptation of video and photo accessories - heating stage - light filters - polarisation - immersio oil and cleaning sets - accessory sets - halogen lamps, spare bulbs, mercury high pressure lamps
48 35 35 35 35 36 36 37 37 37 37 38 38 38 38 38 39
Incident light microscopes and workshop microscopes Product
page
Technical survey on the microscope stand configurations
41
Incident ligh microscopy - metallurgy - quality control of workpieces - quality control / production surveillance
42
Components for upgrade of incident light microscopes - objectives - eyepieces - pointing, measuring and counting with graticules - tubes - discussion tube - trinocular tubes - adaptation of video and photo accessories - spare bulbs
Accessories for repair
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
44 44 45 46 46 46 46 46
60-65
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 2
Stereomicroscopes Product
page
Complete configurations stereo microscopes
48
Stereomicroscope head SK Wiloskop - F Zoom
49
Accessories for stereomicroscopes
49
Stands for stereomicroscope heads
49
External light sources for stereomicroscopes
50
Cameras Digital USB cameras - cameras with CMOS sensor - cameras with CCD sensor
54
Digital D-SLR cameras - camera with ASP - C sensor
54
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 3
Technical survey on the microscope stand configurations Microscope for education Med-Prax
Code no.
008.0314.0
Solid cast-metal stand for reliable standing and smooth microscopy. Coaxial coarse and fine focusing. The coarse focus drive can be adjusted individually. Height adjustment of the coarse drive 20 mm (totally). Height adjustment of the fine drive 1 µm per scale division. Binocular observation tube 360° rotatable. Tube 45° inclined. Tube factor 1x, interpupillary distance 55 mm - 75 mm adjustable. Diopter adjustment: each eyepiece tube can be adjusted individually. Quadruple revolving nosepiece. Mechanical stage 130 mm x 130 mm with ergonomically placed coaxial knobs. Adjustment range 50 mm x 78 mm. Vernier in x-y direction. Specimen holder with spring lever. Condenser NA 1,25 with aperture diaphragm. Condenser height adjustment with gear drive. Condenser can be Köhler adjusted by an adjusting plate (grid) on the illumination head The aperture diaphragm is projected in the rear focus plane. 6 V / 20 W halogen illumination with continuous brightness control.
Laboratory microscopes Medicus series Medicus microscopes are characterised by premium quality mechanics. They can be upgraded to phase contrast, darkfield, LED-Fluorescence and to micro-photography.
Stand configurations with pre-centered field diaphragm
018.0575.0
Solid cast-metal stand in classic swan-neck shape Coaxial coarse and fine focus drives. Height adjustment of the coarse drive 15 mm (total). Height adjustment tot. 15 mm of the fine focus drive 2 µm per scale division. Binocular observation tube 360° rotatable, inclination 30°, tube factor 1x. Interpupillary distance 55 mm - 75 mm, adjustable. Diopter adjustment at each eyepiece tube. Quadruple revolving nosepiece with ball bearing. Mechanical stage 130 mm x 130 mm with ergonomically placed coaxial knobs. Adjustment range 76 mm x 52 mm Specimen holder with spring lever. Condenser height adjustment with gear drive for exact adjustment according to Köhler. Integrated and centered field diaphragm. 6 V / 20 W halogen illumination with continuous brightness control.
Stand configuration with adjustable field diaphragm As stand configuration 018.0575.0 but with costly illumination tube and centreable field diaphragm
018.0678.0
Laboratory microscopes series H 600 Code no. Solid, heavy cast-metal stand, rectangular shape for high expandability. Max. stability for smooth microscopy. Coaxial coarse and fine focusing. Height adjustment of the coarse drive 22 mm (total). Height adjustment of the fine drive 2 µm per scale division. Binocular observation tube 360° rotatable, inclination 30°, tube factor 1x. Interpupillary distance 55 mm - 75 mm adjustable at each observation tube. Quintuple nosepiece with ball track Mechanical stage 160 mm x 130 mm with ergonomically placed coaxial knobs. Adjustment range 76 mm x 52 mm Specimen holder with spring lever. Condenser height adjustment with gear drive for exact adjustment according to Köhler. Sophisticated illumination tube with centerable field diaphragm. 12 V / 30 W halogen illumination with continuous brightness control. The following microscope stand configurations are available: Microscope stand configuration H 600 /12-5 with five objectives, sloping to the back
018.0648.0
Microscope stand configuration H 600/5 as H 600/12-5 but with lowerable stage . Microscope stand configuration H 600 LL / 5 for external adaptation of lightsources, e.g. halogen lamphouses This configuration contains a light guide to prevent the specimen from being damaged by excessive heat
018.0861.0
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
018.0306.0
Issue April 2011
Page 4
Upright microscopes
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 5
Microscopes for education
Main focus of the application: Schools and education Method of contrast: brightfield
Microscope Med-Prax
Code no.
Price
008.0314.0
599 €
019.0764.0
62 €
consisting of: Microscope stand configuration Med-Prax Revolving nosepiece 4x Binocular observation tube (45°, TF 1x) Eyepiece WF 10x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective A 40 / 0,65 spring loaded Objective A 100 / 1,25 Oil spring loaded Condenser NA 1,25 with aperture diaphragm Adjusting plate (grid) Instruction for use Dust cover Set of accessories for Med-Prax, consisting of: Mains cable with plug 1 spare lamp 6 V / 20 W 2 spare fuses Immersion oil nD 1,515, PCB-free, 10 ml
Components for further extension Plano concave mirror, adaptable to illumination tube. This allows sunlight to be used for illumination.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 6
Microscope for the medical practice
Main focus of the application: haematology Method of contrast: brightfield
Medicus HF
Code no.
Price
008.0095.0
920 €
with achromatic objectives consisting of: Microscope stand configuration: Vc Binocular tube (30°TF1x) Eyepiece WF 10x / 18 2x Objective AC 4 / 0,10 Objective AC 10 / 0,25 Objective AC 40 / 0,65 spring loaded Objective AC 100 / 1,25 Oil spring loaded Condenser NA 1,25 - 0.0 with aperture diaphragm Set of accessories VI Instruction for use Dust cover
018.0575.0 019.0558.0 018.0425.0 018.0421.0 018.0422.0 018.0423.0 018.0424.0 018.0505.0 018.9313.0 901.1057.0 902.96066
Medicus HF PL 20
008.0342.0
1.425 €
with plan-achromatic objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration:Vc Binocular tube (30°TF1x) Eyepiece WF 10 x / 20 2x Objective Plan 10 / 0,25 Objective Plan 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Condenser NA 1,25 with aperture diaphragm and filterholder Set of accessories V I Instruction for use Dust cover
H 600 Wilo-Prax Achro
018.0575.0 019.0558.0 019.9037.000 019.9058.000 019.9060.000 019.9062.000 019.0193.0 018.9313.0 901.1041.0 902.96066
008.0372.0
2.020 €
with high quality achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 4 / 0,10 Objective Achro 10 / 0,25 Objective Achro 40 / 0,65 spring loaded Objective Achro 100 / 1,25 (Oil) spring loaded Condenser NA 0,9 Set of accessories H Instruction for use Dust cover
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
018.0648.0 018.0033.0 018.0425.0 019.9051.000 019.9052.000 019.9054.000 019.9056.000 018.0028.0 018.9011.0 901.1046.0 902.0052.0
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 7
Microscopes for medical practice and hospitals
Main focus of the application: haematology, urology Method of contrast: brightfield, phase contrast Urine sediments can be observed in better contrast, when working in phase contrast, in comparison to mere brightfield.
Medicus PH Achro PL
Code no.
Price
008.0344.0
1.250 €
with high quality achromatic objectives and one plan phase contrast objective 40x consisting of: Microscope stand configuration: Vv Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective Plan Ph3 40 / 0,65 spring loaded Objective Achro 100 / 1,25 (Oil) spring loaded Condenser NA 0.9 with aperture diaphragm and filterholder Insert diaphragm for phase contrast (to be inserted in the filterholder of the condenser) for objective Plan Ph3 40 Set of accessories V I Instruction for use Dust cover
018.0678.0 019.0558.0 018.0425.0 019.9052.000 019.9068.000 019.9056.000 018.0028.0 018.0767.0 018.9313.0 901.1041.0 902.96066
Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not contained in the price of the microscope.
018.96149
135 €
Medicus PH Plan
008.0345.0
1.395 €
with plan-achromatic objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration: Vv Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan Ph3 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Condenser NA 0.9 with aperture diaphragm and filterholder Insert diaphragm for phase contrast (to be inserted in the filterholder of the condenser) for objective Plan Ph3 40 Set of accessories V I Instruction for use Dust cover Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not contained in the price of the microscope.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
018.0678.0 019.0558.0 019.9037.000 019.9058.000 019.9068.000 019.9062.000 018.0028.0 018.0767.0 018.9313.0 901.1041.0 902.96066
018.96149
135 €
Issue April 2011
Page 8
Microscopes for shared laboratories and hospitals
H 600 Wilozyt Plan
008.0380.0
2.755 €
with plan-achromatic objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration: H 600/12-5 Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan Ph2 20 / 0,40 Objective Plan Ph3 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Small combination condenser NA 1,25 with aperture diaphragm and filterholder, can be switched from brightfield to phase contrast Set of accessories H Instruction for use Dust cover
018.0648.0 018.0033.0 019.9037.000 019.9058.000 019.9067.000 019.9068.000 019.9062.000 018.0639.0 018.9011.0 901.1046.0 902.0052.0
Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not contained in the price of the microscope.
018.96149
135 €
H 600 Wilozyt Plan ICS
008.0381.0
3.140 €
with infinity corrected plan-achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Tube optics for infinity corrected objectives Eyepiece WF 10 / 18 2x Objective ICS PL 10 / 0,25 Objective ICS PL Ph2 20 / 0,40 Objective ICS PL Ph3 40 / 0,65 spring loaded Objective ICS PL 100 / 1,25 (Oil) spring loaded Small combination condenser NA 1,25 with aperture diaphragm and filterholder, can be switched from brightfield to phase contrast Set of accessories H Instruction for use Dust cover Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not contained in the price of the microscope.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
018.0648.0 018.0033.0 018.0547.0 018.96226 019.9046.000 019.9071.000 019.9072.000 019.9049.000 018.0639.0 018.9011.0 901.1046.0 902.0052.0
018.96149
135 €
Issue April 2011
Page 9
Microscopes for pathology and bacteriology
Method of contrast: brightfield Code number
H 600 Wilo-Prax PL
008.0390.0
Price 2.185 €
with plan-achromatic objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 20 Objective Plan 4 / 0,10 Objective Plan 10 / 0,25 Objective Plan 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Condenser NA 0,9 Set of accessories H Instruction for use Dust cover
018.0648.0 018.0033.0 019.9037.000 019.9057.000 019.9058.000 019.9060.000 019.9062.000 018.0028.0 018.9011.0 901.1046.0 902.0052.0
2x
Equipment for detection of mycoses: Compact fluorescence illuminator with LED light source (395 nm), TF 1x, with beam splitter 400 nm, barrier filter LP 580 nm and power supply
018.0837.0
1.495 €
Fluorescence dye (fluorochrome) Mykoval 10 ml
902.0067.0
95 €
H 600 Wilo-Prax ICS
008.0414.0
2.950 €
with infinity corrected plan-achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Tube optics for infinity objectives Eyepiece WF 10 x / 18; 2 pcs. Objective ICS PL 4 / 0,10 Objective ICS PL 10 / 0,25 Objective ICS PL 40 / 0,65 Objective ICS PL 100 / 1,25 Oil, spring loaded Condenser 0,9 Set of accessories H Instruction for use Dust cover
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
2x
Subject to change without notice Right reserved to modify technical data
018.0648.0 018.0033.0 018.0547.0 018.0425.0 019.9045.000 019.9046.000 019.9048.000 019.9049.000 018.0028.0 018.9011.0 901.1046.0 902.0052.0
Issue April 2011
Page 10
Method of contrast: brightfield, phase contrast Code number
H 600 PH Plan
008.0353.0
Price 2.995 €
with plan-achromatic phase contrast objectives and large field of view (F.O.V. 20) consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 20 2x Objective Plan Ph1 10 / 0,10 Objective Plan Ph3 40 / 0,65 spring loaded Objective Plan Ph4 100 / 1,25 Oil spring loaded Large combination condenser NA 1,25 with aperture diaphragm and filterholder, switchable for brightfield and phase contrast with centering telescope Set of accessories H Instruction for use Dust cover
018.0648.0 018.0033.0 019.9037.000 019.9066.000 019.9068.000 019.9069.000 018.0835.0 018.9010.0 901.1046.0 902.0052.0
Method of contrast: brightfield, phase contrast, incident fluorescence light
H 600 AFL PH Plan 50
008.0354.0
6.265 €
with plan-achromatic phase contrast objectives consisting of: Microscope stand configuration H 600/12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan Ph2 20 / 0,40 Objective Plan Ph3 40 / 0,65 spring loaded Objective Plan Ph4 100 / 1,25 Oil spring loaded Large combination condenser NA 1,25 with aperture diaphragm and filterholder, switchable for brightfield and phase contrast with centering telescope Incident fluorescence illuminator for filterslider Filterslider for up to 2 filterblocks Filterblock D for incident fluorescence light (FITC) Illumination unit HBO 50, consisting of: Lamphouse HBO 50 with collector, mirror, lampmount and heat protection filter Hg high pressure lamp 50 W Power supply HBO 50 including mains cable Set of accessories H / AFL Instruction for use Dust cover
H 600 AFL PH Plan 100
018.0648.0 018.0033.0 019.9050.000 019.9058.000 019.9067.000 019.9068.000 019.9069.000 018.0835.0 018.0754.0 018.0745.0 018.0454.0 018.0237.0 662.96290 018.0373.0 018.9014.0 901.1033.0 902.96670
008.0382.0
7.340 €
Same configuration as H 600 AFL Plan 50 but with illumination system HBO 100
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 11
Equipment for immunology Method of contrast: brightfield, incident fluorescence light Code number
H 600 AFL Achro 50
008.0355.0
Price 5.645 €
with high quality achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective Achro 40 / 0,65 spring loaded Objective Achro 100 / 1,25 (Oil) spring loaded Condenser NA 1,25 Incident fluorescence illuminator for filterslider Filterslider for up to 2 filterblocks Filterblock D for incident fluorescence light (FITC) Illumination unit HBO 50, consisting of: Lamphouse HBO 50 with collector, rear mirror, lamp mount and heat protection filter Hg high pressure mercury lamp 50 W Power supply unit HBO 50 including mains cable Set of accessories H / AFL Instruction for use Dust cover
H 600 AFL Achro 100
018.0648.0 018.0033.0 019.9050.000 019.9052.000 019.9054.000 019.9056.000 019.0193.0 018.0754.0 018.0745.0 018.0454.0 018.0237.0 662.96290 018.0373.0 018.9014.0 901.1033.0 902.96670
008.0383.0
6.720 €
008.0356.0
5.850 €
008.0384.0
6.925 €
008.0357.0
6.160 €
008.0385.0
7.235 €
Same configuration as H 600 AFL Achro 50, but with illumination unit HBO 100
H 600 AFL Plan 50 Same configuration as H 600 AFL Achro 50 but with plan achromatic objectives
H 600 AFL Plan 100 Same configuration as H 600 AFL Plan 50, but with illumination unit HBO 100
H 600 AFL Plan ICS 50 Same configuration as H 600 AFL Achro 50 but with infinity corrected plan-achromatic objectives
H 600 AFL Plan ICS 100 Same configuration as H 600 AFL Plan ICS 50, but with illumination unit HBO 100 and infinity corrected plan-achromatic objectives
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 12
H 600 AFL PH 40 Plan 50
008.0359.0
5.935 €
with plan-achromatic objectives consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan Ph 40 / 0,65 spring loaded Objective Plan 100 / 1,25 (Oil) spring loaded Small combination condenser NA 0,9 for brightfield and phase contrast Incident fluorescence illuminator for filterslider Filterslider for up to 2 filterblocks Filterblock D for incident fluorescence light (FITC) Illumination unit HBO 50, consisting of: Lamphouse HBO 50 with collector, rear mirror, lamp mount and heat protection filter Hg high pressure mercury lamp 50 W Power supply unit HBO 50 including mains cable Set of accessories H / AFL Instruction for use Dust cover
018.0648.0 018.0033.0 019.9050.000 019.9058.000 019.9068.000 019.9062.000 019.0072.0 018.0754.0 018.0745.0 018.0454.0 018.0237.0 662.96290 018.0373.0 018.9014.0 901.1033.0 902.96670
Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope.
018.96149
135 €
H 600 AFL PH 40 Plan 100
008.0387.0
7.020 €
008.0360.0
6.245 €
008.0388.0
7.330 €
Code number 018.0451.0
Price 815 €
Filterset D (FITC) Excitation range 450 - 490 nm, Dichroic mirror 510 nm, suppression filter 520 nm
018.0454.0
485 €
Filterset E (TRITC) Excitation range 515 - 560 nm, Dichroic mirror 580 nm, suppression filter 580 nm
018.0455.0
485 €
Filterset G (Mykoval) Excitation range 355 - 425 nm, Dichroic mirror 400 nm, suppression filter 455 nm
018.0442.0
485 €
Filterset Texas Red Excitation range 540 - 580 nm Dichroic mirror 595 nm, suppression filter 600 - 660 nm
018.0602.0
1.125 €
Filterset Rhodamin (red version) Excitation range 546 nm, Dichroic mirror 565 nm, suppression filter 600 - 660 nm
018.0603.0
1.125 €
Same equipment as H 600 AFL PH Achro 50, but with illumination unit HBO 100
H 600 AFL PH Plan ICS 50 Same equipment as H 600 AFL PH Plan 50 but with plan-achromatic objectives, infinity corrected
H 600 AFL PH Plan ICS 100 Same equipment as H 600 AFL Plan ICS 50, but with illumination unit HBO 100 and plan-achromatic objectives, infinity corrected
Filtersets for H 600 AFL Filterset A (DAPI) Excitation range 340 - 380 nm, Dichroic mirror 400 nm, suppression filter 435 - 485 nm
Further filterblocks upon request Incorporation of further filtersets (per filterset)
60 €
Filterslider for fluorescence Filterslider for 2 filtersets
018.0745.0
365 €
Filterslider for 4 filtersets
018.0746.0
550 €
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 13
Microscopes with heating stage
Main focus of the application: living specimens, fertility investigations Method of contrast: brightfield, phase contrast Code number
Medicus PH Plan HT
008.0361.0
Price 2.350 €
with plan-achromatic objectives consisting of: Microscope stand configuration: Vv Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Plan 10 / 0,25 Objective Plan 20 / 0,40 Objective Plan Ph3 40 / 0,65 spring loaded Small combination condenser NA 0,9 with aperture diaphragm and filterholder for brightfield and phase contrast Small heating stage HT 50 up to 50°C Control unit for HT 50, Input 100-240 V AC / 0,4 A, Output 12 V DC / 1,25 A Set of accessories V III Instruction for use Dust cover Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
018.0678.0 019.0558.0 018.0425.0 019.9058.000 019.9059.000 019.9068.000 018.0287.1 018.0465.0 018.0655.0 018.9307.0 901.1014.0 902.96066
018.96149
135 €
Issue April 2011
Page 14
LED-incident light fluorescence Method of contrast: brightfield, incident fluorescence with LED Code number
Medicus LED AFL Myko
008.0364.0
Price 2.485 €
with high quality achromatic objectives consisting of: Microscope stand configuration Vv Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2 pieces Objective Achro 20 / 0,40 Objective Achro 40 / 0,65 spring loaded Condenser NA 0,9 Compact incident fluorescence illuminator with LED lightsource (395 nm), TF 1x, with: dichroic mirror 400 nm, suppression filter LP 580 nm and power supply unit Fluorescence dye (fluorochrome) Mykoval 10 ml Set of accessories V I Instruction for use Dust cover
Medicus LED AFL FITC
018.0575.0 019.0558.0 018.96226 019.9053.000 019.9054.000 018.0028.0 018.0837.0 632.0024.0 902.0067.0 018.9313.0 901.1041.0 902.96066
008.0405.0
2.585 €
008.0406.0
2.585 €
008.0407.0
2.635 €
008.0378.0
2.915 €
Same configuration as Medicus AFL Myko but with LED-Fluorescence-Illuminator FITC
Medicus LED AFL TRITC Same configuration as Medicus AFL Myko but with LED-Fluorescence-Illuminator TRITC
Medicus LED AFL DAPI Same configuration as Medicus AFL Myko but with LED-Fluorescence-Illuminator DAPI
Method of contrast: brightfield, phase contrast, incident fluorescence with LED
Medicus PH LED AFL Myko with high quality achromatic objectives and one plan phase contrast objective 40 x consisting of: Microscope stand configuration Vv Binocular tube (30°TF1x) Eyepiece WF 10 x / 18 2 pieces Objective Achro 10 / 0,25 Objective Plan Ph 40 / 0,65 spring loaded Objective Plan 40 /0,65 spring loaded Condenser NA 0.9 with aperture diaphragm and filterholder Drop-in diaphragm for phase contrast (to be inserted in the filterholder of the condenser) for objective Plan Ph2 40 Compact incident fluorescence illuminator with LED-lightsource (395 nm), TF 1x, with: dichroic mirror 400 nm, suppression filter LP 580 nm and power supply unit Fluorescence dye (fluorochrome) Mykoval 10 ml Set of accessories V I Instruction for use Dust cover
018.0678.0 019.0558.0 018.96226 019.9052.000 019.9068.000 019.9060.000 018.0028.0 018.0767.0 018.0837.0 902.0067.0 018.9313.0 901.1041.0 902.96066
Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope.
018.96149
135 €
Medicus PH LED AFL FITC
008.0408.0
3.015 €
008.0409.0
3.015 €
008.0410.0
3.065 €
Same configuration as Medicus PH LED AFL Myko but with LED-Fluorescence-Illuminator FITC
Medicus PH LED AFL TRITC Same configuration as Medicus PH LED AFL Myko but with LED-Fluorescence-Illuminator TRITC
Medicus PH LED AFL DAPI Same configuration as Medicus PH LED AFL Myko but with LED-Fluorescence-Illuminator Dapi
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 15
Method of contrast: brightfield, incident fluorescence with LED
H 600 LED AFL Myko consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective SPL 20 / 0,50 Objective Achro 40 / 0,65 spring loaded Condenser NA 0,9 Compact incident fluorescence illuminator with LED lightsource (395 nm), TF 1x, with: dichroic mirror 400 nm, suppression filter LP 580 nm and power supply unit Fluorescence dye (fluorochrome) Mykoval 10 ml Set of accessories H Instruction for use Dust cover
H 600 LED AFL FITC
Code number
Price
008.0365.0
3.595 €
018.0648.0 018.0033.0 018.96226 019.0532.0 019.9054.000 018.0028.0 018.0837.0 902.0067.0 018.9011.0 901.1041.0 902.96670
008.0411.0
3.695 €
008.0412.0
3.695 €
008.0413.0
3.750 €
Same configuration as H 600 LED AFL Myko but with LED-Fluorescence-Illuminator FITC
H 600 LED AFL TRITC Same configuration as H 600 LED AFL Myko but with LED-Fluorescence-Illuminator TRITC
H 600 LED AFL DAPI Same configuration as H 600 LED AFL Myko but with LED-Fluorescence-Illuminator DAPI
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 16
Equipment for investigations of native blood in darkfield
Main focus of the application: investigation of native blood in darkfield acc. to Prof. Enderlein
H 600 LL HP 100 consisting of: Microscope stand configuration H 600 LL / 5 Trinocular tube (360° TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective SPL 100 / 1,25-0,60 (Oil) with iris diaphragm, spring loaded Darkfield condenser NA 1,4 Collector II Halogen illumination 12 V / 100 W, consisting of: Lamphouse HAL 100 with collector, rear mirror, lamp mount and heat protection filter Power supply unit for halogen lamp 12 V / 100 W, halogen lamp 12 V / 100 W Set of accessories H LL Instruction for use Dust cover
Code number
Price
008.0368.0
4.420 €
018.0306.0 018.0033.0 018.96226 019.9052.000 019.0489.0 019.0182.0 018.0276.0 018.0324.0 018.9018.0 901.1038.0 902.96670
Equipment for investigations of microorganisms in liquids
Main focus of the application: breweries Method of contrast: brightfield, phase contrast, darkfield
H 600 Wilo-Brau consisting of: Microscope stand configuration H 600 /12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective Plan Ph 3 40 / 0,65 spring loaded Objective A 63 / 0,85 spring loaded Small combination condenser NA 1,25 with aperture diaphragm and filterholder for brightfield, phase contrast and darkfield up to objective 63x (darkfield drop in diaphragm necessary) Darkfield drop in diaphragm for objective A 63 / 0,85 Set of accessories H Instruction for use Dust cover
Code number
Price
008.0370.0
2.465 €
018.0648.0 018.0033.0 018.0425.0 019.9052.000 019.9068.000 018.96640 018.0639.0
503.69465 018.9010.0 901.1046.0 902.0052.0
Main focus of the application: sewage treatment plants (activated sludge) Method of contrast: brightfield, phase contrast, darkfield
H 600 BS
008.0371.0
consisting of: Microscope stand configuration H 600 / 12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective Achro 10 / 0,25 Objective Plan Ph 3 40 / 0,65 spring loaded Objective Plan Ph 4 100 / 1,25 Oil spring loaded Large combination condenser NA 0,9 (HF, DF, PH 3 / 4) Set of accessories H BS Instruction for use Dust cover
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
2.830 €
018.0648.0 018.0033.0 018.0425.0 019.9052.000 019.9068.000 019.9069.000 018.0818.0 018.9013.0 901.1046.0 902.0052.0
Issue April 2011
Page 17
Polarising microscopes Laboratory microscopes for investigations in polarised light Method of contrast: brightfield, polarisation (orthoscopical investigations)
H 600 POL consisting of: Microscope stand configuration H 600 / 12-5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 Objective Plan 10 / 0,25 Objective Plan 20 / 0,40 spring loaded Objective Plan 40 / 0,65 spring loaded Objective Plan 60 / 0,85 spring loaded Condenser NA 1,25
Code number
Price
008.0286.0
3.720 €
018.0648.0 018.0033.0 018.0425.0 019.9058.000 019.9059.000 019.9060.000 019.9061.000 019.0193.0
2x
Large polarising equipment HP I, consisting of: - polariser, rotatable, can be attached to the condenser - analyser, can be rotated 90° Round centering and rotating stage with scale (360°) and vernier Object guide for round centering and rotating stage with low positioned control knobs Set of accessories H Instruction for use Dust cover Optional: Centering telescope for conoscopical investigations. Can be used instead of a Bertrand lens.
019.0115.0 019.0178.0 019.96280 018.9011.0 901.1076.0 902.96670
018.96149
135 €
008.0243.0
4.855 €
Laboratory microscopes for investigations in polarised light with powerful lightsource. Method of contrast: brightfield, polarisation (orthoscopical)
H 600 LL POL 50 consisting of: Microscope stand configuration H 600 LL / 5 Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 Objective Plan 10 / 0,25 Objective Plan 20 / 0,40 spring loaded Objective Plan 40 / 0,65 spring loaded Objective Plan 60 / 0,85 spring loaded Condenser NA 1,25 Collector II
018.0306.0 018.0033.0 018.0425.0 019.9058.000 019.9059.000 019.9060.000 019.9061.000 019.0193.0 018.0276.0
2x
Halogen illumination 12 V / 50 W Lamphouse HAL 50 with collector, reflector, lampmount and heat protection filter halogen lamp 12 V / 50 W Power supply for halogen lamp 12 V / 50 W
018.0323.0
Large polarising equipment HP I, consisting of: - polariser, rotatable, can be attached to the condenser - analyser, can be rotated 90° - box for storage Round centering and rotating stage with scale (360°) and vernier Object guide for round centering and rotating stage with low positioned control knobs Set of accessories H Instruction for use Dust cover
019.0115.0 019.0178.0 019.96280 018.9017.0 901.1077.0 902.96670
Optional: Centering telescope for conoscopical investigations. Can be used instead of a Bertrand lens.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
018.96149
135 €
Issue April 2011
Page 18
Polarising microscopy - components The modular concept of the Hund microscope program offers attachment of components for polarising microscopy for existing microscopes. This is valid for orientating polarisation in biology, medicine and metallurgy.
Rotatable and centerable stage with scale division (360°) and vernier.
019.0178.0
550 €
Object guide for rotatable and centerable stage with flat control knobs.
019.96280
365 €
018.96177
105 €
019.0115.0
640 €
Small polarising equipment HP II, consisting of: > polariser with arm, that can be placed on the illumination head > analyser on filterslider, that can be placed in the tube slot of the microscope
019.0106.0
95 €
Filter Slider with polariser for incident light
018.0666.0
120 €
For microscopes series V (Medicus, Vb 365, etc): Small polarising equipment WP II consisting of: > polariser, that can be placed in the filterholder of the condenser > analyser, that can be placed on the eyepiece For microscopes series H 600: Large polarising equipment HP I, consisting of: > rotatable polariser, that can be attached to the condenser > analyser 90° rotatable (disengageable) > compensator 1st order red (disengageable) > storage case
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 19
Components for further upgrade of upright microscopes Objectives High quality Achro-objectives Tube length 160 mm These objectives are high quality achromatic objectives, which are outstanding for their excellent image quality. These objectives can be used with eyepieces with the field of view 20. Achro
4/0,10
019.9051.000
41 €
Achro
10/0,25
019.9052.000
52 €
Achro
20/0,40
019.9053.000
62 €
Achro
40/0,65 spring loaded
019.9054.000
72 €
Achro
60/0,85 spring loaded
019.9055.000
93 €
019.9056.000
103 €
Achro 100/1,25 Oil, spring loaded Recommended eyepieces: 018.96763.1 / 019.9037.000
Plan-objectives Tube length 160 mm Plan-achromatic objectives for highest demands. These objectives can be used with eyepieces with field of view 20. Plan
2,5/0,07
019.9999.090
160 €
Plan
4/0,10
019.9057.000
52 €
Plan 10/0,25
019.9058.000
82 €
Plan 20/0,40
019.9059.000
125 €
Plan 40/0,65 spring loaded
019.9060.000
155 €
Plan 60/0,85 spring loaded
019.9061.000
200 €
Plan 100/1,25 Oil, spring loaded Recommended eyepieces: 019.9037.000 / 018.96763.1
019.9062.000
230 €
Code number 019.0489.0
Price 715 €
019.9999.128
350 €
019.9054.000
72 €
018.96659
230 €
Components for further upgrade of upright microscopes Special objectives SPL Objektive for darkfield with highest magnifications : SPL
100 / 1,25-0,60 Oil with iris diaphragm
For low magnification : S-Plan 2/0,05 For use in combination with counting chambers : A 40/0,65 spring loaded A Ph2 40/0,65 spring loaded Recommended eyepiece: 018.0425.0
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 20
ICS PL-Objectives Tube length: infinity High quality plan-achromatic objectives, infinity corrected ICS PL
4/0,10
019.9045.000
93 €
ICS PL
10/0,25
019.9046.000
105 €
ICS PL
20/0,45
019.9047.000
210 €
ICS PL
40/0,65 spring loaded
019.9048.000
250 €
019.9049.000
310 €
SPL 20/0,50
019.0532.0
290 €
FL 50/1,0 Oil, spring loaded
019.0070.0
505 €
ICS PL 100/1,25 Oil spring loaded Recommended eyepieces: 018.96226 / 019.9050.000 / 019.9050.000
Fluorite objective FL-objective Tube length 160 mm for haematological investigations and fluorescence microscopy
Phase contrast objectives
Plan-achromatic phase contrast objectives Tube length
160 mm
PL Ph 1
10/0,25
019.9066.000
125 €
PL Ph 2
20/0,35
019.9067.000
155 €
PL Ph 3
40/0,65 spring loaded
019.9068.000
200 €
019.9069.000
250 €
PL Ph 4 100/1,25 Oil, spring loaded Recommended eyepieces: 019.9050.000 / 019.9037.000
Plan-achromatic ICS-phase contrast objectives (Tube length: infinity) ICS PL Ph 1
10/0,25
019.9070.000
200 €
ICS PL Ph 2
20/0,35
019.9071.000
250 €
ICS PL Ph 3
40/0,65 spring loaded
019.9072.000
340 €
019.9073.000
455 €
ICS PL PH 4 100/1,25 Oil spring loaded Recommended eyepieces: 019.9050.000 / 019.9037.000
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 21
Condensers and accessories Brightfield condensers with aperture diaphragm and filterholder Code number 018.0028.0
Price 82 €
019.0193.0
125 €
018.0125.0
10 €
Small combination condenser NA 0,9 for all brightfield objectives and for phase contrast with two objectives, if no immersion oil is used for the condenser.
019.0072.0
290 €
Small combination condenser NA 1,25 for all brightfield objectives and for phase contrast with objectives A Ph2 20x, A Ph2 40x and darkfield up to objective A 40x. A ground glass filter should be inserted into the filterholder of the condenser, when using the 4x objective.
018.0834.0
290 €
Ground glass filter, diameter 32 mm (in box)
018.0125.0
10 €
019.9063.000
375 €
Large combination condenser NA 0,9 for all brightfield objectives and for phase contrast objectives 10:1, 20:1, 40:1, 100:1. Case for large combination condenser
018.0710.0 018.96586
445 € 41 €
Large combination condenser NA 1,25 for all brightfield objectives and for phase contrast objectives 10:1, 20:1, 40:1, 100:1, resp. for 3 phase contrast objectives & darkfield up to 40:1.
018.0835.0
455 €
Centering telescope for adjusting phase contrast. Can be used instead of Betrand lens.
018.96149
135 €
019.0182.0
445 €
Conversion filter BG 28, diameter 32 mm (in box)
019.0363.0
10 €
Conversion filter BG 28 and ground glass filter, diameter 32 mm (in box)
018.96089
21 €
Green filter VG 9, diameter 32 mm (in box)
018.96173
21 €
Ground glass filter, diameter 32 mm (in box)
018.0125.0
10 €
Filterslider II with conversion filter BG 28 and green filter VG 9 to be inserted in the upper part of upper part of the microscope stand
018.0123.0
31 €
Yellow filter, diameter 32 mm (in box)
018.0782.0
10 €
019.9075.000
21 €
Condenser NA 0,9 for all brightfield objectives also for objectives 100:1, if no immersion oil for the condenser is used. Condenser NA 1,25 recommended for all brightfield objectives from 10 x if high NA's are required. For the objective 4x, a ground glass filter must be placed in the filterholder of the condenser. Ground glass filter, diameter 32 mm (in box)
Combination condensers for brightfield, phase contrast and darkfield with aperture diaphragm and filterholder
Phase contrast condenser NA 1.25 for plan objectives (160 mm tube length) with centering telescope
Special darkfield condensers Darkfield condenser NA 1,4 for brilliant darkfield with objective 100x with iris diaphragm.
Light filters
Eyepieces H5x WF
10 x / 18 pupil distance 13 mm simple style
018.0425.0
21 €
WF
10 x / 18 pupil distance 13 mm
018.96226
82 €
WF
10 x / 18 B pupil distance 24 mm for spectacle wearers
018.96792
105 €
WF
10 x / 18 pupil distance 13 mm
019.9050.000
31 €
WF
12,5 x / 18, pupil distance 11 mm
018.96284
185 €
WF
12,5 x / 18 B, pupil distance 24 mm for spectacle wearers
018.96794
210 €
WF
10 x / 20 M
019.9037.000
41 €
WF
15 x / 17, pupil distance 11 mm
018.96500
93 €
Eyeguards, benzene-and xylol-proof Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
902.97300 Subject to change without notice Right reserved to modify technical data
5€ Issue April 2011
Page 22
Components for further upgrade of upright microscopes Pointing, measuring, counting and calibration with graticules
Measuring eyepieces differ from normal eyepieces in their construction. Therefore they cannot be used combined with normal eyepieces. For observation with two eyes a second measuring eyepiece without graticule, used as a complement eyepiece, is necessary.
Pointing Code number 018.0712.0
Price 105 €
018.96226
82 €
018.0478.001
240 €
018.0478.0
210 €
Micrometer eyepiece WF10x / 18 with cross hair contains graticule 059.0032.0 Complement eyepiece WF 10 x / 18
018.0478.002
240 €
018.0478.0
210 €
Micrometer eyepiece WF10x / 18 10 mm = 100 divisions contains graticule 059.14054 Complement eyepiece WF 10 x / 18
018.0478.003
240 €
018.0478.0
210 €
Code number 018.0478.005
Price 260 €
018.0478.0
210 €
018.0478.004
405 €
018.0478.0
210 €
Stage micrometer for transmitted light 1 mm = 100 divisions 2 mm = 200 divisions
019.96133 019.96723
93 € 105 €
Stage micrometer for incident light 1 mm = 100 divisions
019.96843
93 €
WF 10 x / 18 with pointer contains pointer 503.0226.0 Complement eyepiece WF 10 x / 18 (for SPL and PL-objectives)
Cross hair eyepiece WF 10x / 18 contains graticule 059.14053 Complement eyepiece WF 10 x / 18
Measuring
Eyepieces shown above are also available at 12,5x
Components for further upgrade of upright microscopes Counting Counting eyepiece WF 10x 10 x 10 lines; 10 mm x 10 mm contains graticule 059.14057 Complement eyepiece WF 10 x
Eyepiece WF 10x G 22 Walton and Beckett contains graticule 059.0108.0 Complement eyepiece WF 10 x
20x3 10x3 5x5/
5 7 9
Calibration
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 23
Components for further upgrade of upright microscopes Tubes Binocular tube C inclined 30°, TF=1x
019.0558.0
210 €
Binocular tube H inclined 30°, TF=1x
018.0033.0
405 €
018.0467.0
1.515 €
902.0079.0
15 €
Trinocular phototube 30 / 70 inclined 30°, TF=1x, beam splitting 30% visual / 70% documentation (fixed)
018.0034.0
610 €
Trinocular phototube 100 / 100 inclined 30°, TF=1x, beam splitting 100% visual / 100% documentation (changeable)
019.0505.0
875 €
018.0810.0
215 €
Video-adapter without intermediate optics (1x) (C-Mount) for trinocular phototubes
019.0094.0
93 €
Video-adapter with intermediate optics 0,5x (C-Mount) for trinocular phototubes
019.0453.0
105 €
Video-adapter with intermediate optics 1,6x (C-Mount) for trinocular phototubes
019.0442.0
175 €
018.0837.0
1.495 €
Fluorescence dye (fluorochrome) Mycoval 10 ml
902.0067.0
93 €
LED incident light fluorescence-illuminator FITC
018.0839.0
1.600 €
018.0840.0
1.600 €
018.0838.0
1.650 €
For education of a second observer Discussion bridge DB 2 for a 2nd observer with pointer, that can be operated by both observers Dust cover for discussion bridge The discussion bridge can be adapted to all professional laboratory microscopes. For information please contact our technical service.
Trinocular tubes Tubes for adaptation of photo- or video equipment
Equipment for photomicrography Prerequisite: Tube for adaptation of photo- respectively video equipment For adaptation of SLR cameras Adapter set for Canon SLR cameras incl. Photo eyepiece T 2 adapter for adaptation of other SLR-cameras to phototubes upon request. For adaptation of cameras pls. contact our technical service
Adaptation of video- and photo systems in combination with trinocular phototube 018.0034.0 / 019.0505.0 or replacement tube
For adaptation of photo equipment please contact our technical service.
LED-Fluorescence-Illuminators LED incident light fluorescence illuminator Myko LED light source (365 nm), TF 1x, with filter set for Mykoval and wall power supply
Fluorescence dye/ Mycoval
LED lightsourec (470 nm), TF 1x, with filter set for FITC and wall power supply
LED incident light fluorescence-illuminator TRITC LED lightsourec (530 nm), TF 1x, with filter set for TRITC and wall power supply
LED incident light fluorescence-illuminator DAPI LED lightsourec (365 nm), TF 1x, with filter set for DAPI and wall power supply
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 24
Attachable mirror for illumination via external light sources for example the sun Plano concave mirror is placed on the illumination tube of the microscopes V and H. Diameter 50 mm
018.0348.0
62 €
Immersion oil nD 1,515 PCB-free, 10 ml
902.0066.0
15 €
Faxo-Clean cleaning liquid 30 ml
902.0065.0
8€
019.9999.132
41 €
Specimen holder, metal for 2 specimens
018.0263.0
21 €
Specimen holder, plastic, chromed for 1 specimen
018.0383.0
31 €
018.0655.0 018.0465.0 018.0664.0
330 € 270 € 540 €
019.0501.0
2.390 €
Code number
Price
Wooden cabinet for Med-Prax
902.0099.0
103 €
Wooden cabinet for V-microscopes
902.96070
103 €
Wooden cabinet for H 600
902.0073.0
103 €
Case for transportation (plastic, black)
902.0039.0
82 €
Dust cover for V-microscopes
902.96066
10 €
Dust cover for H 600 / stereomicroscopes
902.0052.0
10 €
Dust cover H 600 AFL, H 600 LL
902.96670
10 €
Dust cover for microscope with discussion bridge DB 2
902.0079.0
15 €
Interior packing (styrofoam)
905.0025.0
21 €
Immersion oil and cleaning liquids
Optical cleaning set, consisting of: Cleaning liquid 30 ml Anti-static cleaning cloth Anti-static brush Grabber stick for absorbing dust particles
Specimen holders
Heating stages for upright microscopes Small heating stage HT 50 (up to 50°C) adaptable to microscope stage, consisting of: Control unit (including mains cable, Input 100 V-240 V AC / 0,4 A Output 12 V DC / 1,25 A) Small heating stage HT 50 (incl mains cable 12 V / 15 W) Optional: Warming plate (incl. mains cable 12 V / 30 W) Large heating stage HMT-H with control unit HT 200 and pre-heating plate Separate regulation of the heating stage 43° and pre-heating plate 48° C in steps of 0,5°C from ambient temperature to 50°C. Digital temperature selection and display for the heating stage and the warming plate. Temperature constancy +/- 0,2°C
For storage and transport
Wooden cabinets, cases for transportation, dust covers
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 25
Sets of accessories for the microscopes Medicus Microscopes Code number 018.9313.0 625.56362 662.0003.0 018.0369.0 019.0120.0 902.0066.0
Price 42,30 € 10,20 € 11,00 € 3,50 € 2,60 € 15,00 €
Set of accessories V II Mains cable with safety plug 1 halogen lamp 6 V / 20 W (spare) 2 spare fuses 230 V, 0,2 ATR 2 centering keys SW 1,5 Conversion filter BG 28 and ground glass filter, diameter 32 mm (in box) Immersion oil nD 1,515, PCB-free, 10 ml
018.9322.0 625.56362 662.0003.0 018.0369.0 019.0120.0 018.96089 902.0066.0
62,30 € 10,20 € 11,00 € 3,50 € 2,60 € 20,00 € 15,00 €
Set of accessories V III Mains cable with safety plug 1 halogen lamp 6 V / 20 W (spare) 2 spare fuses 230 V, 0,2 ATR 2 centering keys SW 1,5 Conversion filter BG 28 and ground glass filter, diameter 32 mm (in box) Green filter VG 9 Immersion oil nD 1,515, PCB-free, 10 ml
018.9307.0 625.56362 662.0003.0 018.0369.0 019.0120.0 018.96089 018.96173 902.0066.0
82,30 € 10,20 € 11,00 € 3,50 € 2,60 € 20,00 € 20,00 € 15,00 €
Set of accessories H Mains cable with safety plug 1 halogen lamp 12 V / 30 W (spare) 2 spare fuses 230 V, 0,2 ATR 2 centering keys SW 1,5 Filterslider II H 600 with conversion filter BG 28 and green filter VG 9 Ground glass filter in box Immersion oil nD 1,515, PCB-free, 10 ml Eyeguards, benzene and xylol-proof, 2 pieces
018.9011.0 625.56362 662.0009.0 018.0369.0 019.0120.0 018.0123.0 018.0125.0 902.0066.0 902.97300
90,40 € 10,20 € 13,00 € 3,50 € 2,60 € 30,00 € 10,00 € 15,00 € 6,10 €
Set of accessories H/AFL Mains cable with safety plug 1 halogen lamp 12 V / 30 W (spare) 2 spare fuses 230 V, 0,2 ATR Immersion oil nD 1,515, PCB-free, 10 ml Eyeguards, benzene- and xylol-proof, 2 pieces Centering keys 1.5 Protective gloves Protective glasses
018.9014.0 625.56362 662.0009.0 018.0369.0 902.0066.0 902.97300 018.55855 599.0017.0 599.0016.0
76,60 € 10,20 € 13,00 € 3,50 € 15,00 € 6,10 € 3,00 € 10,30 € 15,50 €
Set of accessories H LL 2 centering keys SW 1,5 Immersion oil nD 1,515, PCB-free, 10 ml Eyeguards, benzene and xylol-proof, 2 pieces Filterslider II H 600 with conversion filter BG 28 and green filter VG 9
018.9018.0 019.0120.0 902.0066.0 902.97300 018.0123.0
45,40 € 2,60 € 15,00 € 6,10 € 29,00 €
Set of accessories H LL NH 2 centering keys SW 1,5 Filterslider II H 600 with conversion filter BG 28 and green filter VG 9 Immersion oil nD 1,515, PCB-free, 10 ml Eyeguards, benzene and xylol-proof, 2 pieces
018.9019.0 019.0120.0 018.0123.0 902.0066.0 902.97300
52,70 € 2,60 € 29,00 € 15,00 € 6,10 €
Set of accessories V I Mains cable with safety plug 1 halogen lamp 6 V / 20 W (spare) 2 spare fuses 230 V, 0,2 ATR 2 centering keys SW 1,5 Immersion oil nD 1,515, PCB-free, 10 ml
H-Microscopes
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 26
Components for further upgrade of upright microscopes
Halogen lamps
Halogen lamp 6 V / 10 W socket G4 Single Set (6 pieces)
Code number 662.96236 018.96277
Price 9€ 46 €
662.0003.0 018.96891
11,00 57 €
662.0010.0 018.0513.0
15 € 80 €
662.0009.0
13 €
662.96229
18 €
662.0005.0
18 €
Suitable for: - V 300/C 300 until production date 11.99 / serial number 1008600 - BX 300 - Stereomicroscope stands SM-AD - Wilovert A until production date end 86 / serial number 200850 - S 200
Halogen lamp 6 V / 20 W socket G4 Single Set (6 pieces) Suitable for: - H 500 until 10.99 / 1008500 - V 300 / C 300 from 12.99 / 1008900 - Wilovert until 10.99 / 1008400
Halogen lamp 6 V / 30 W socket G4 Single Set (6 pieces) Suitable for: - H 600 from 11.99 / 1008550
Halogen lamp 12 V / 30 W socket G4 Suitable for: - Wilovert from 1.2000 / 1008600 - H 600
Halogen lamp 12 V / 50 W socket G 5,3 / 6,35 Suitable for: - H 600 LL, Incident illuminator AM, (at H 600 and WAD), Metallovert
Halogen lamp 12 V / 100 W socket G 6,35 Suitable for: - H 600 LL, Wilovert LL, Incident illuminator AM, (at H 600 and WAD)
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 27
Components for further upgrade of upright microscopes Lamps Lamp 220 V / 15 W E14 Single Set (6 pieces)
Code number 663.0001.0 018.96095
Price 6€ 29 €
661.96052
13 €
661.96004 018.96029
14 € 72 €
018.96005
25 €
663.96084
11 €
661.97310
11 €
662.96290
185 €
662.0006.0
210 €
Suitable for: - Vb 150, Vb 155, Vb 250, Vm 250, attachable lamp 018.96230 and 018.96001
Lamp 6 V / 15 W E14 Suitable for : - V 100 (a transformer is prerequisite) Vb 100, Vb 150, BX 100
Lamp 6 V / 15 W Single Set (6 piece)
BA 15 d
Suitable for: - BX 200 (with round base and transformer) LTKU
Lamp 6 V / 15 W centered socket Suitable for: - BX 200 incident illuminator WAD (old)
Lamp 220 V / 20 W partially reflected BA 15 Suitable for: - Vb 250 K, Vb 250 R
Lamp 6 V / 7 W Suitable for: - Stereomicroscope stand (old)
Mercury high pressure lamps Hg-high pressure lamp 50 W Suitable for: - H 500 AFL 50, H 600 AFL 50, Wilovert AFL 50
Hg-high pressure lamp 100 W Suitable for: - H 500 AFL 100, H 600 AFL 100, Wilovert AFL 100
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 28
Inverted Microscopes
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 29
Technical survey on the microscope stand configurations Microscope stand configuration Wilovert
Code no. 018.0693.0
for brightfield and phase contrast Heavy U-shaped all cast body. Ergonomically placed coaxial coarse and fine focusing knobs. Height adjustment of the coarse drive 22 mm (total). Height adjustment of the fine drive: 2 µm per scale drive. Binocular observation tube 360° rotatable, 30° inclined. Interpupillary distance 55 mm - 75 mm adjustable. Diopter adjustment at both eyepiece tubes. Large, fixed microscope stage 210 mm x 235 mm Quintuple revolving nosepiece with ball bearing. Integrated in the microscope base is an halogen illumination 12 V / 30 W, continuously adjustable.
Microscope stand configuration Wilovert AFL
018.0695.0
for incident fluorescence light, also in combination with brightfield and phase contrast Heavy U-shaped all cast body with integrated beam path for incident light illumination. Adapter for HBO- and halogen lamphouses. Ergonomically placed coaxial coarse and fine focusing knobs. Height adjustment of the coarse drive 22 mm (total). Height adjustment of the fine drive: 2 µm per scale drive. Binocular observation tube, 360° rotatable, 30° inclined. Interpupillary distance 55 mm - 75 mm adjustable. Diopter adjustment at each eyepiece tube. Large, fixed microscope stage 210 mm x 235 mm. Quintuple revolving nosepiece with ball bearing. Powerful supply for the 12 V / 30 W halogen illumination, continuously adjustable.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 30
Method of contrast: brightfield
Wilovert Standard HF / K
008.0303.0
2.230 €
up to objective 10 x consisting of: Microscope stand configuration Wilovert Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 lllumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Set of accessories WS Instruction for use Dust cover
018.0693.0 018.0033.0 019.9050.000 018.96634.1 018.96635 018.0628.0 018.96677 018.9550.0 901.1049.0 902.96670
Main focus of the application: Plancton, sediments, cell cultures, tissue cultures Method of contrast: brightfield
Wilovert Standard HF 20
Code number
Price
008.0309.0
2.385 €
up to objective 20 x consisting of: Microscope stand configuration Wilovert Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective SPL 20 / 0,35 (LD) lllumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Set of accessories WS Instruction for use Dust cover
Wilovert Standard PH 20
018.0693.0 018.0033.0 019.9050.000 018.96634.1 018.96635 018.96698 018.0628.0 018.96677 018.9550.0 901.1018.0 902.96670 008.0305.0
2.855 €
008.0304.0
3.545 €
Same equipment as Wilovert Standard HF 20, but with phase contrast for objectives 10x and 20x and combi condenser NA 0,25
Wilovert Standard HF 40 up to objective 40 x consisting of: Microscope stand configuration Wilovert Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective SPL 20 / 0,35 (LD) Objective SPL 40 / 0,60 (LD) in correction mount lllumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Object guide (left hand control) Set of accessories WS Instruction for use Dust cover
Wilovert Standard PH 40
018.0693.0 018.0033.0 019.9050.000 018.96634.1 018.96635 018.96698 019.0449.0 018.0628.0 018.96677 019.0079.0 018.9500.0 901.1018.0 902.96670
008.0306.0
4.015 €
Same configuration as Wilovert Standard HF 40 but with phase contrast for objectives 10x, 20x, 40x, combi condenser NA 0,25 and object guide (left hand control) Holding frames for culture vessels: please see accessories
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 31
Main focus of the application: cell culture research, investigations in fluorescence Method of contrast: brightfield, incident fluorescence light
Wilovert AFL 20
Code number
Price
008.0307.0
6.650 €
Up to objective 20 x consisting of: Microscope stand configuration AFL Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective SPL 20 / 0,35 (LD) Illumination unit HBO 100 Lamphouse HBO 100 with collector, mirror, lamp mount and heat protection filter Mercury high pressure lamp 100 W Power supply unit HBO 100 including mains cable Filterslider for up to 2 filtersets Filterset D for immunofluorescence (FITC) blue excitation Illumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Set of accessories WS AFL Instruction for use Dust cover
018.0695.0 018.0033.0 018.0425.0 018.96634.1 019.9052.000 018.96698 018.0314.0 662.0006.0 018.0504.0 018.0745.0 018.0454.0 018.0628.0 018.96677 018.9554.0 901.1044.0 902.96670
Holding frames for culture vessels: please see accessories
Wilovert AFL 40
008.0308.0
7.820 €
Up to objective 40 x consisting of: Microscope stand configuration AFL Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A 10 / 0,25 Objective SPL 20 / 0,35 (LD) Objective SPL 40 / 0,60 (LD) in correction mount Illumination unit HBO 100 Lamphouse HBO 100 with collector, mirror, lamp mount and heat protection filter Mercury high pressure lamp 100 W Power supply unit HBO 100 including mains cable Filterslider for up to 2 filtersets Filterset D for immunofluorescence (FITC) blue excitation Illumination unit 12 V / 30 W halogen Brightfield condenser NA 0,25 for attachment to the illumination unit Object guide (left hand control) Set of accessories WS AFL Instruction for use Dust cover
018.0695.0 018.0033.0 018.0425.0 018.96634.1 018.96635 018.96698 019.0449.0 018.0314.0 662.0006.0 018.0504.0 018.0745.0 018.0454.0 018.0628.0 018.96677 019.0079.0 018.9554.0 901.1044.0 902.96670
Holding frames for culture vessels: please see accessories
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 32
Method of contrast: brightfield, phase contrast, incident fluorescence light
Wilovert AFL 20 Phako
Code number
Price
008.0300.0
7.170 €
up to objective 20 x consisting of: Microscope stand configuration AFL Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective A 4 / 0,10 Objective A Ph 1 10 / 0,25 Objective SPL 20 / 0,35 (LD) Objective SPL Ph2 20 / 0,35 (LD) Filterslider for up to 2 filtersets Filterset for immunofluorescence FITC (blue excitation) Illumination unit 12 V / 30 W halogen Combination condenser NA 0,25 for brightfield and phase contrast Ph1/ 2 for attachment to the illumination unit Illumination unit HBO 100 Lamphouse HBO 100 with collector, mirror, lamp mount and heat protection filter Mercury high pressure lamp 100 W Power supply unit HBO 100 including mains cable Set of accessories WS AFL Instruction for use Dust cover Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope.
018.0695.0 018.0033.0 018.0425.0 018.96634.1 018.96657 018.96698 018.96699 018.0745.0 018.0454.0 018.0628.0 018.96673
018.0314.0 662.0006.0 018.0504.0 018.9554.0 901.1044.0 902.96670
018.96149
135 €
008.0301.0
8.350 €
Method of contrast: brightfield, phase contrast and incident fluorescence
Wilovert AFL 40 Phako up to objective 40 x consisting of: Microscope stand configuration AFL Binocular tube (30°TF 1x) Eyepiece WF 10 x / 18 2x Objective AC 4 / 0,10 Objective A Ph 1 10 / 0,25 Objective SPL 20 / 0,35 (LD) Objective SPL Ph2 20 / 0,35 (LD) Objective SPL Ph2 40 / 0,60 (LD) in correction mount Combination condenser NA 0,25 for brightfield and phase contrast Ph1/ 2 for attachment to the illumination unit Illumination unit 12 V / 30 W halogen Filterslider for up to 2 filtersets Filterset for immunofluoresence FITC (blue excitation) Illumination unit HBO 100 Lamphouse HBO 100 with collector, mirror, lamp mount and heat protection filter Mercury high pressure lamp 100 W Power supply unit HBO 100 including mains cable Object guide (left hand control) Set of accessories WS AFL Instruction for use Dust cover
018.0695.0 018.0033.0 018.0425.0 018.96634.1 018.96657 018.96698 018.96699 019.0468.0 018.96673 018.0628.0 018.0745.0 018.0454.0 018.0314.0 662.0006.0 018.0504.0 019.0079.0 018.9554.0 901.1044.0 902.96670
Holding frames for culture vessels: please see accessories Optional Centering telescope for correct adjustment of the phase contrast, if this is required by the user according to Medical Device Operator Ordinance. Not included in the price of the microscope.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
018.96149
135 €
Issue April 2011
Page 33
Filtersets for Wilovert AFL Code number 018.0451.0
Price 815 €
Filterset D (FITC) Excitation range 450 - 490 nm, dichroic mirror 510 nm, suppression filter 520 nm
018.0454.0
485 €
Filterset E (TRITC) Excitation range 515 - 560 nm, dichroic mirror 580 nm, suppression filter 580 nm
018.0455.0
485 €
Filterset G (Mykoval) Excitation range 355 - 425 nm, dichroic mirror 400 nm, suppression filter 455 nm
018.0442.0
485 €
Filterset Texas Red Excitation range 540 - 580 nm dichroic mirror 595 nm, suppression filter 600 - 660 nm
018.0602.0
1.125 €
Filterset Rhodamin (red version) Excitation range 546 nm, dichroic mirror 565 nm, suppression filter 600 - 660 nm
018.0603.0
1.125 €
Filterset A (DAPI) Excitation range 340 - 380 nm, dichroic mirror 400 nm, suppression filter 435 - 485 nm
Assembly of further filtersets (per filterset)
60 €
Further filtersets upon request
Filtersliders for fluorescence Filterslider for 2 filtersets
018.0745.0
365 €
Filterslider for 4 filtersets
018.0746.0
550 €
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 34
Components for further upgrade of inverted microscopes Objectives Brightfield objectives
Code number 018.96634.1
Price 52 €
Achromatic objective A 10 / 0,25 Free working distance 7,0 mm
018.96635
72 €
Semiplan achromatic objective SPL 20 / 0,35 (LD) Free working distance 4,0 mm
018.96698
175 €
Semiplan achromatic objective SPL 40 / 0,60 (LD) with correction mount Free working distance 4,7 mm, correction range 0,6 - 1,6 mm
019.0449.0
550 €
Achromatic objective A Ph1 10 / 0,25 Free working distance 7,0 mm
018.96657
155 €
Semiplan achromatic objective SPL Ph2 20 / 0,35 (LD) Free working distance 4,0 mm
018.96699
260 €
Semiplan achromatic objective SPL Ph2 40 / 0,60 (LD) with correction mount Free working distance 4,7 mm, correction range 0,6 - 1,6 mm
019.0468.0
610 €
018.96677
125 €
018.96673
290 €
018.96693
310 €
019.0079.0
610 €
018.96691 018.96678 018.96679 018.96680 018.96681 018.96853 018.96682 018.96683 018.96684 018.96685 018.96686 018.96687 018.96688 018.96689 018.96690 018.96890
93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 € 93 €
Achromatic objective A 4 / 0,10 Free working distance 18 mm
Phase contrast objectives
Condensers Brightfield condensers Brightfield condenser NA 0,25 for adaptation to the illumination unit
Combination condensers Combination condensers for brightfield and phase contrast Combination condenser NA 0,25 for adaptation to the illumination unit. For brightfield objectives 4/10/20/40 and phase contrast objectives Ph1/2 10/20. Combination condenser NA 0,40 for adaptation to the illumination unit. For brightfield objectives 4/10/20/40 and phase contrast objective PH 1/2 10/20/40.
Object guide Object guide for holding frames, left hand control
Holding frame for culture vessels 2 brackets for roller bottles for stage 210 x 235 mm Holding frame Terasaki for 60/72/120 well trays Holding frame for vessels with 96 well trays / multiwell plates Holding frame for Hamax with 60 well trays Holding frame for Petri dishes, diameter 36 mm Holding frame for Petri dishes, diameter 42 mm Holding frame for Petri dishes, diameter 54 mm Holding frame for Petri dishes, diameter 65 mm Holding frame for Petri dishes, diameter 88 mm Holding frame for Costar vessels Holding frame for Corning vessels Holding frame for object guides 76 x 26 mm (3x1 inch), with specimen clips Holding frame for Costar with 24 sample fields, round Holding frame for Costar vessels with 24 sample fields, (squares) Holding frame for Greiner + Falcon vessels Holding frame for plankton chambers, diameter 43 mm
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 35
Components for further upgrade of inverted microscopes Eyepieces Code number 018.0425.0
Price 21 €
018.96792
105 €
019.9037.000
41 €
Widefield eyepiece WF 12,5/18
018.96284
185 €
Widefield eyepiece WF 12,5x/18 B also suitable for spectacle wearers with eyeguards
018.96794
210 €
Widefield eyepiece WF 10x/18 Widefield eyepiece WF 10x/18 B also suitable for spectacle wearers with eyeguards Widefield eyepiece WF 10x/20 with field of view 20 also suitable for spectacle wearers
Pointing, measuring, counting and calibration with graticules Measuring eyepieces differ from normal eyepieces in their construction. Therefore they cannot be used combined with normal eyepieces. For observation with two eyes a second measuring eyepiece without graticule, used as a complement eyepiece, is necessary .
Pointing Code number
Price
018.0712.0
105 €
018.96226
82 €
018.0478.001
240 €
018.0478.0
210 €
Micrometer eyepiece WF10x / 18 with cross hair contains graticule 059.0032.0 Complement eyepiece WF 10 x / 18
018.0478.002
240 €
018.0478.0
210 €
Micrometer eyepiece WF10x / 18 10 mm = 100 divisions contains graticule 059.14054 Complement eyepiece WF 10 x / 18
018.0478.003
240 €
018.0478.0
210 €
018.0478.005
260 €
018.0478.0
210 €
018.0478.004
405 €
018.0478.0
210 €
Stage micrometer for transmitted light 1 mm = 100 divisions 2 mm = 200 divisions
019.96133 019.96723
93 € 105 €
Stage micrometer for incident light 1 mm = 100 divisions
019.96843
93 €
WF 10 x / 18 with pointer contains pointer 503.0226.0 Complement eyepiece WF 10 x / 18 (for SPL and PL-objectives)
Cross hair eyepiece WF 10x / 18 contains graticule 059.14053 Complement eyepiece WF 10 x / 18
Measuring
Components for further upgrade of inverted microscopes Counting Counting eyepiece WF 10x 10 x 10 lines; 10 mm x 10 mm contains graticule 059.14057 Complement eyepiece WF 10 x 20x3 10x3 5x5/
Eyepiece WF 10x G 22 Walton and Beckett contains graticule 059.0108.0 Complement eyepiece WF 10 x
5 7 9
Calibration
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 36
Components for further upgrade of inverted microscopes Tubes Code number
Price
Binocular tube C inclined 30°, TF=1x
019.0558.0
210 €
Binocular tube H inclined 30°, TF=1x
018.0033.0
405 €
018.0467.0
1.515 €
902.0079.0
15 €
Trinocular phototube 30 / 70 inclined 30°, TF=1x, beam splitting 30% visual / 70% documentation (fixed)
018.0034.0
610 €
Trinocular phototube 100 / 100 inclined 30°, TF=1x, beam splitting 100% visual / 100% documentation (changeable)
019.0505.0
875 €
018.0810.0
215 €
Video-adapter without intermediate optics (1x) (C-Mount) for trinocular phototubes
019.0094.0
93 €
Video-adapter with intermediate optics 0,5x (C-Mount) for trinocular phototubes
019.0453.0
105 €
Video-adapter with intermediate optics 1,6x (C-Mount) for trinocular phototubes
019.0442.0
175 €
For education of a second observer Discussion bridge DB 2 for a second observer with pointer, that can be operated by both observers Dust cover for discussion bridge The discussion bridge can be adapted to all professional laboratory microscopes. For information please contact our technical service. Observation tubes and eyepieces are to be ordered separately, since these are not contained in the discussion bridge.
Trinocular tubes Tubes for adaptation of photo- or video equipment
Equipment for photomicrography Prerequisite: Tube for adaptation of photo- respectively video equipment For adaptation of SLR cameras Adapter set for Canon SLR cameras incl. Photo eyepiece T 2 adapter for adaptation of other SLR-cameras to phototubes upon request.
Adaptation of video- and photosystems in combination with trinocular phototube 018.0034.0 / 019.0505.0 or replacement tube
For adaptation of photo equipment please contact our technical service.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 37
Components for further upgrade of inverted microscopes Heating stage Code number
Price
018.0662.0
505 €
018.0655.0
330 €
018.0664.0
540 €
018.96747 018.96748
41 € 31 €
018.0459.0
125 €
Immersion oil nD 1,515 PCB-free, 10 ml
902.0066.0
15 €
Faxo-Clean cleaning liquid 30 ml
902.0065.0
8€
019.9999.132
41 €
Set of accessories WS Mains cable with safety plug 1 halogen lamp 12 V / 30 W (spare) 2 spare fuses 230 V, 0,2 ATR Green filter VG 9 in slip-on mount for the condenser Allen key, SW 4 mm, chromed
Code number 018.9550.0 625.56362 662.0009.0 018.0369.0 018.96747 902.0084.0
Price 66,50 € 10,20 € 13,00 € 3,50 € 35,80 € 4,00 €
Set of accessories WS AFL Mains cable with safety plug 1 halogen lamp 12 V / 30 W (spare) 2 spare fuses 230 V, 0,2 ATR Tube for adjustment Protective glasses Protective gloves Allen key, SW 4 mm, chromed Allen key SW 3 mm Green filter VG 9 in slip-on mount for the condenser 2 centering keys SW 1,5 x 45 Eyeguards
018.9554.0 625.56362 662.0009.0 018.0369.0 018.0598.0 599.0016.0 599.0017.0 902.0084.0 902.96851 018.96747 019.0120.0 902.97300
148,30 € 10,20 € 13,00 € 3,50 € 41,70 € 15,50 € 10,30 € 4,00 € 3,00 € 35,80 € 5,20 € 6,10 €
Small heating stage HT up to 50° C for Wilovert, integrated in the Wilovert stage plate (including plug in unit 12 V / 30 W) Control unit for HT 50 (including plug in unit Input 100 V-240 V AC / 0,4 A Output 12 V DC / 1,25 A) Warming plate (including plug in unit 12 V / 30 W)
Lightfilters for adaptation to the condenser, that is attached to the illumination unit Greenfilter VG 9 in slip-on mount for condenser Conversion filter (day light filter) in slip-on mount for condenser
Polarisation Polarisation equipment for Wilovert
Immersion oil and cleaning liquids
Optical cleaning set, consisting of: Cleaning liquid 30 ml Anti-static cleaning cloth Anti-static brush Grabber stick for absorbing dust particles
Components for further upgrade of inverted microscopes
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 38
Halogen lamps
Halogen lamp 6 V / 10 W socket G4 Single Set (6 pieces)
Code number 662.96236 018.96277
Price 9€ 46 €
662.0003.0 018.96891
11 € 57 €
662.0009.0
13 €
Code number 662.96229
Price 18 €
662.0005.0
18 €
662.96290
185 €
662.0006.0
210 €
Suitable for: - V 300/C 300 until production date 11.99 / serial number 1008600 - BX 300 - Stereomicroscope stands SM-AD - Wilovert A until production date end 86 / serial number 200850 - S 200
Halogen lamp 6 V / 20 W socket G4 Single Set (6 pieces) Suitable for: - H 500 until 10.99 / 1008500 - V 300 / C 300 from 12.99 / 1008900 - Wilovert until 10.99 / 1008400
Halogen lamp 12 V / 30 W socket G4 Suitable for: - Wilovert from 1.2000 / 1008600 - H 600
Components for further upgrade of inverted microscopes
Halogen lamp 12 V / 50 W socket G 5,3 / 6,35 Suitable for : - H 600 LL incident light illuminator AM, (at H 600 and WAD), Metallovert, Wilovert LL
Halogen lamp 12 V / 100 W socket G 6,35 Suitable for: - H 600 LL, Wilovert LL, incident light illuminator AM (at H 600 and WAD), Wilovert LL
Mercury high pressure lamps Hg-mercury high pressure lamp 50 W Suitable for: - H 500 AFL 50, H 600 AFL 50, Wilovert AFL 50
Hg-mercury high pressure lamp 100 W Suitable for: - H 500 AFL 100, H 600 AFL 100, Wilovert AFL 100
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 39
Incident light microscopy and workshop microscopes
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 40
Technical survey on the microscope stand configurations Incident light microscopes series H 600 Code no. Solid, heavy cast-metal stand, rectangular shape for high expandability. Maximal stability guarantees smooth microscopy. Coaxial coarse and fine focusing. Height adjustment of the coarse drive 22 mm (total). Height adjustment of the fine drive 2 µm per scale division. Binocular observation tube 360° rotatable, inclination 30°, tube factor 1x. Interpupillary distance 55 mm - 75 mm adjustable at each observation tube. Quadruple nosepiece - quintuple nosepiece available as option. Mechanical stage 160 mm x 130 mm with ergonomically placed coaxial knobs. Adjustment range 76 mm x 52 mm The following microscope stand configurations are available: Microscope stand configuration H 600 /12-4 for incident and transmitted light with condenser height adjustment. Sophisticated illumination tube with centerable field diaphragm. Condenser height adjustment for exact illumination according to Köhler.
018.0649.0
Microscope stand configuration H 600 / 4 with lowerable stage, so that for example polished sections of 50 mm height can be examined.
018.0438.0
Microscope stand configuration W-AD for quality control and production surveillance Stand for incident and transmitted light with column Maximal object height 180 mm Microscope stage 170 x 150 mm Microscope body with thoothed gear Coaxial coarse and fine focus Quadrupe revolving nosepiece
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 41
Main focus of the application: metallurgy, quality control of workpieces Method of contrast: Incident light brightfield
H 600 AM 50 consisting of: Microscope stand configuration H 600/12-4 with lowerable stage Binocular tube (30°TF 1x) Eyepiece WF 10x / 18 2x Objective EPI A 4 / 0,13 Objective EPI A 10 / 0,30 Objective EPI A 20 / 0,50 Objective EPI A 40 / 0,60 Compact incident light illuminator AM with field diaphragm, aperture diaphragm and filterslider Halogen illumination 12 V / 50 W consisting of: Lamphouse HAL 50 with collector, rear mirror, lamp mount and heat protection filter Power supply for halogen lamp 12 V / 50 W, halogen lamp 12 V / 50 W Set of accessories H Instruction for use Dust cover
Code number
Price
008.0223.0
3.595 €
018.0438.0 018.0033.0 018.96226 019.0519.0 019.0520.0 019.0521.0 019.0522.0 018.0783.0 018.0323.0 019.9016.0 901.1079.0 902.96670
Method of contrast: Incident light brightfield, transmitted light brightfield
H 600 AM AL/DL 50
008.0288.0
consisting of: Microscope stand configuration H 600 /12-4 with lowerable stage Binocular tube (30°TF 1x) Eyepiece WF 10x / 18 2x Objective EPI A 4 / 0,13 Objective EPI A 10 / 0,30 Objective EPI A 20 / 0,50 Objective EPI A 40 / 0,60 Condenser NA 0,9 Compact incident light illuminator AM with field diaphragm, aperture diaphragm and filterslider Halogen illumination 12 V / 50 W consisting of: Lamphouse HAL 50 with collector, rear mirror, lamp mount and heat protection filter Power supply for halogen lamp 12 V / 50 W, halogen lamp 12 V / 50 W Set of accessories H Instruction for use Dust cover
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
3.925 €
018.0649.0 018.0033.0 018.96226 019.0519.0 019.0520.0 019.0521.0 019.0522.0 018.0028.0 018.0783.0 018.0323.0 018.9011.0 901.1079.0 902.96670
Issue April 2011
Page 42
Workshop microscope
Main focus of the application: quality control and production surveillance
W-AD 50 consisting of: Microscope stand configuration W-AD Microscope body with gear drive Binocular tube (30°TF 1x) Eyepiece WF 10x / 18 2 Stück Objective EPI A 4 / 0,13 Objective EPI A 10 / 0,30 Objective EPI A 20 / 0,50 Objective EPI A 40 / 0,60 Incident light illuminator AM with field diaphragm, aperture diaphragm and filterslider Fibre light source FLQ M Flexible light guide 1,5 m length Opal disc Set of accessories W-AD Instruction for use Dust cover Set of accessories W-AD Mains cable with safety plug 1 spare fuse 1 spare bulb 6 V / 10 W
Code number
Price
008.0415.0
3.790 €
018.0398.0 018.0355.0 018.0033.0 018.96226 019.0519.0 019.0520.0 019.0521.0 019.0522.0 018.0783.0 003.0040.0 060.0177.027 059.10976 018.9700.0 901.1037.0 902.96670 018.9700.0 625.56362 018.0612.0 662.96236
22,70 € 10,20 € 3,50 € 9,00 €
019.96852
550 €
Adjustment range = 50 mm/resolution = 0,01 mm
019.96838
240 €
Adjustment range = 50 mm/resolution = 0,005 mm
019.96839
250 €
Holding device for x-direction, diameter 12 mm
019.0185.0
41 €
Holding device for y-direction, diameter 12 mm
019.0186.0
41 €
Adjustment range = 50 mm/resolution = 0,001 mm
019.96840
1.230 €
Holding device for x-direction, diameter 18 mm
019.0188.0
52 €
Holding device for y-direction, diameter 18 mm
019.0189.0
52 €
Measuring stages for workshop microscope W-AD Coordinate plane table, adjustment range 50 x 50 mm (can only be mounted in the factory)
At this stage the following micrometer spindles can be adapted:
Micrometer spindle with drum reading adaptable to the coordinate stage
Micrometer spindles with digital display adaptable to the coordinate stage
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 43
Components for further upgrade of incident light microscopes Achromatic incident light objectives EPI A Achromatically corrected objectives, for use without cover glasses.
EPI A
4/0,13 free working distance 11,657
Code number 019.0519.0
Price 52 €
EPI A
10/0,30 free working distance 6,742
019.0520.0
82 €
EPI A
20/0,50 free working distance 0,838
019.0521.0
145 €
EPI A
40/0,65 spring loaded free working distance 0,467
019.0522.0
155 €
EPIA
60/0,75 spring loaded free working distance 0,58 mm
019.9201.000
395 €
Widefield eyepiece WF 10x/18
018.0425.0
21 €
Widefield eyepiece WF 10x/18 B also suitable for spectacle wearers with eyeguards
018.96792
105 €
019.9037.000
41 €
Widefield eyepiece WF 12,5/18
018.96284
185 €
Widefield eyepiece WF 12,5x/18 B also suitable for spectacle wearers with eyeguards
018.96794
210 €
Recommended eyepiece 018.96226
Eyepieces
Widefield eyepiece WF 10x/20 with field of view 20 also suitable for spectacle wearers
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 44
Pointing, measuring, counting and calibration with graticules
Measuring eyepieces differ from normal eyepieces in their construction. Therefore they cannot be used combined with normal eyepieces. For observation with two eyes a second measuring eyepiece without graticule, used as a complement eyepiece, is necessary.
Pointing WF 10 x / 18 with pointer contains pointer 503.0226.0 Complement eyepiece WF 10 x / 18 (for SPL and PL-objectives)
018.0712.0
105 €
018.96226
82 €
018.0478.001
240 €
018.0478.0
210 €
Code number 018.0478.002
Price 240 €
018.0478.0
210 €
018.0478.003
240 €
018.0478.0
210 €
018.0478.005
260 €
018.0478.0
210 €
018.0478.004
405 €
018.0478.0
210 €
Stage micrometer for transmitted light 1 mm = 100 divisions 2 mm = 200 divisions
019.96133 019.96723
93 € 105 €
Stage micrometer for incident light 1 mm = 100 divisions
019.96843
93 €
Cross hair eyepiece WF 10x / 18 contains graticule 059.14053 Complement eyepiece WF 10 x / 18
Components for further upgrade of incident light microscopes Measuring Micrometer eyepiece WF10x / 18 with cross hair contains graticule 059.0032.0 Complement eyepiece WF 10 x / 18
Micrometer eyepiece WF10x / 18 10 mm = 100 divisions contains graticule 059.14054 Complement eyepiece WF 10 x / 18
Counting Counting eyepiece WF 10x 10 x 10 lines; 10 mm x 10 mm contains graticule 059.14057 Complement eyepiece WF 10 x
Eyepiece WF 10x G 22 Walton and Beckett contains graticule 059.0108.0 Complement eyepiece WF 10 x
20x3 10x3 5x5/
5 7 9
Eyepieces shown above are also avialable at 12,5x magnification
Calibration
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 45
Components for further upgrade of incident light microscopes Tubes Binocular tube C inclined 30°, TF=1x
Code number 019.0558.0
Price 210 €
Binocular tube H inclined 30°, TF=1x
018.0033.0
405 €
018.0467.0
1.515 €
902.0079.0
15 €
Trinocular phototube 30 / 70 inclined 30°, TF=1x, beam splitting 30% visual / 70% documentation (fixed)
018.0034.0
610 €
Trinocular phototube 100 / 100 inclined 30°, TF=1x, beam splitting 100% visual / 100% documentation (changeable)
019.0505.0
875 €
018.0810.0
215 €
Video-adapter without intermediate optics (1x) (C-Mount) for trinocular phototubes
019.0094.0
93 €
Video-adapter with intermediate optics 0,5x (C-Mount) for trinocular phototubes
019.0453.0
103 €
Video-adapter with intermediate optics 1,6x (C-Mount) for trinocular phototubes
019.0442.0
175 €
662.96229
18 €
662.0005.0
18 €
For education of a second observer Discussion bridge DB 2 for a second observer with pointer, that can be operated by both observers Dust cover for discussion bridge
Observation tubes and eyepieces are to be ordered separately, since these are not contained in the discussion bridge.
Trinocular tubes Tubes for adaptation of photo- or video equipment
Equipment for photomicrography Prerequisite: Tube for adaptation of photo- respectively video equipment For adaptation of SLR cameras Adapter set for Canon SLR cameras incl. Photo eyepiece T 2 adapter for adaptation of other SLR-cameras to phototubes upon request.
Adaptation of video- and photosystems in combination with trinocular phototube 018.0034.0 / 019.0505.0 or replacement tube
For adaptation of photo equipment please contact our technical service.
Spare lamps
Halogen lamp 12 V / 50 W socket G 5,3 / 6,35 Suitable for: - H 600 LL incident light illuminator AM, (at H 600 and WAD), Metallovert
Halogen lamp 12 V / 100 W socket G 6,35 Suitable for: - H 600 LL, Wilovert LL, incident light illuminator AM (at H 600 and WAD)
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 46
Stereomicroscopes
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 47
Complete stereomicroscope configurations Stereomicroscope Wiloskop - F Zoom with stand ST
008.0402.0
910 €
008.0403.0
1.090 €
without illumination Trinocular zoom body Greenough system Magnification range: 6,7x - 45x, with eyepieces WF 10 x / 22 Diopter adjustment: individually at both eyepiece tubes Rack-and-pinion focusing drive with tension adjustment Black-and-white stage plate, 2 stage clips Illumination/Method of contrast: Illumination via external light sources, as described in the paragraph: Light sources for stereomicroscopes
Stereomicroscope Wiloskop - F Zoom with stand ST - AD LED with LED incident and transmitted light illumination Trinocular zoom body Greenough system Magnification range: 6,7x - 45x, with eyepieces WF 10 x / 22 Diopter adjustment: individually at both eyepiece tubes
Rack-and-pinion focusing drive with tension adjustment Black-and-white stage plate, 2 stage clips Illumination/Contrasting method: Incident light-brightfield: LED array approx. 2W brightness. The lamp is rotatable and the brightness is continuously adjustable. Transmitted light-brightfield: LED array approx. 2W brightness. The lamp is rotatable and the brightness is continuously adjustable. Low-voltage wall power supply
Stereomicroscope Wiloskop - F Zoom with stand ST - S
008.0404.0
970 €
POL unit for Wiloskop
019.9999.142
250 €
LED ringlight
019.9999.156
380 €
Control unit for LED ringlight
019.9999.155
430 €
Foot for LED spot
019.9999.157
90 €
Goose nack illumination
019.9999.158
60 €
LED spot white
019.9999.159
195 €
LED spot warm white
019.9999.160
195 €
Diffuser for LED spot
019.9999.161
40 €
503.0938.0
45 €
019.9999.172
335 €
without illumination Trinocular zoom body Greenough system Magnification range: 6,7x - 45x, with eyepieces WF 10 x / 22 Diopter adjustment: individually at both eyepiece tubes Heavy cast-metal, circular base Rack-and-pinion focusing drive with tension adjustment Illumination/Method of contrast: Illumination via external light sources, as described in the paragraph: Light sources for stereomicroscopes
Accessories for Stereo Microscopes
Adapator ring for LED ringlight Micrometer calibration scale On object carrier 76 mm x 50 mm with division 0,1 mm mand 2" resp. 0,005" division in wodden case
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 48
Stereomicroscope head SK Wiloskop - F Zoom
019.9101.000
750 €
Eyepieces WF 15 x / 16 (pair) WF 20 x / 12 (pair)
019.9105.000 019.9105.001
70 € 70 €
Measuring Eyepiece WF 10 x / 22r with micrometer scale (10 mm in 100 divisions)
019.9105.002
100 €
Eyeguards 1 pair
019.9105.003
10 €
Auxiliary lenses 0,3 x 0,5 x 1,5 x 2,0 x
019.9104.000 019.9104.001 019.9104.002 019.9104.003
90 € 90 € 90 € 90 €
018.0857.0 018.0858.0
150 € 130 €
019.9103.001 019.9999.092
80 € 37 €
019.9102.000
160 €
019.9102.001
340 €
Trinocular zoom body Greenough system Magnification range: 6,7x - 45x, with eyepieces WF 10 x / 22 Diopter adjustment: individually at both eyepiece tubes
Accessories for Stereomicroscope head SK Wiloskop - F Zoom
Adaptation of C-Mount-Cameras Adapter for C-Mount-Cameras 0,5 x Adapter for C-Mount-Cameras 1,0 x Adaptation of digital SLR-Cameras Phototube for D-SLR with photo eyepiece 4x (a specific T2-Adapter is needed) T2-Adapter for Canon D-SLR
Stereo microscope stands Microscope Stand ST without illumination Rack-and-pinion focusing drive with tension adjustment Black-and-white stage plate, 2 stage clips Illumination/Method of contrast: Illumination via external light sources, as described in the paragraph: Light sources for stereomicroscopes
Incident Transmitted Light - Microscope Stand ST - AD LED
Rack-and-pinion focusing drive with tension adjustment Black-and-white stage plate, 2 stage clips Illumination/Contrasting method: Incident light-brightfield: LED array approx. 2W brightness. The lamp is rotatable and the brightness is continuously adjustable. Transmitted light-brightfield: LED array approx. 2W brightness. The lamp is rotatable and the brightness is continuously adjustable. Low-voltage wall power supply
Microscope Stand ST - S boom stand - without illumination
019.9102.002
220 €
902.0052.0 902.96096 018.96189
10 € 10 € 3€
Heavy cast-metal, circular base Rack-and-pinion focusing drive with tension adjustment Illumination/Method of contrast: Illumination via external light sources, as described in the paragraph: Light sources for stereomicroscopes
Accessories for stereomicroscopes Dust cover for stereomicroscopes with stand ST and ST - AD LED Dust cover for stereomicroscopes with stand ST - S Specimen holder (1 piece) Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 49
External lightsources for stereomicroscopes Cold light sources Code number
Price
003.0023.000 003.0022.000
420 € 420 €
662.0002.0
21 €
Goose neck lightguide Number of the arms: 1 Length: 65 cm Diameter active: 4 mm
060.0102.027
93 €
Goose neck lightguide Number of the arms: 2 Length: 65 cm Diameter active: 4 mm
060.0100.027
165 €
Goose neck lightguide Number of the arms: 3 Length: 65 cm Diameter active: 4 mm
060.0114.027
220 €
Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 3 mm Adapter necessary
060.0155.027
93 €
500.0011.0
21 €
Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 8 mm Adapter necessary
060.0184.027
125 €
500.0013.0
21 €
Ringlight Number of the lightpoints: 4 Adapterring
060.0805.027
250 €
503.0890.0
41 €
Ringlight Number of the lightpoints: 8 Adapterring
060.0806.027
365 €
503.0890.0
41 €
Ringlight Number of the lightpoints: continuous ring Adapterring
060.1042.027
415 €
503.0890.0
41 €
Cold light source FLQ 85 E / M Operating voltage: 110 V - 115 V / AC Operating voltage: 220 V - 230 V / AC upon request also available in 100 V, 200 V, 240 V Frequency: 50 / 60 Hz Power consumption: 120 W Electrical connection: Safety plug, safety class 1 Fuse: 0,8 A for 200 V-240 V, 1,6 AT for 100 V-110 V Lamp: Mirror lamp 3,8 V / 85 W Lifetime: approx. 1000 hours Optic: 3-lens condenser with heat protection filter Colour temperature: 3200° K at full power Dimensions: 112 mm (H) x 125 mm (B) x 255 mm (D) Weight: approx. 3,2 kg Housing: aluminium, steel plate Brightness control: electronically / optomechanically Certification: CE Accessories: Mirror lamp 13,8 V / 85 W (spare) Lightguides
Further lightguides upon request. Production of customized lightguides possible.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 50
Cold light source FLQ 150 M
Code number
Price
003.0041.000 003.0040.000
490 € 490 €
662.0004.0
21 €
Goose neck lightguide Number of the arms: 1 Length: 50 cm Diameter active: 4 mm
060.0966.027
82 €
Goose neck lightguide Number of the arms: 2 Length: 50 cm Diameter active: 4 mm
060.0967.027
145 €
Goose neck lightguide Number of the arms: 3 Length: 50 cm Diameter active: 4 mm
060.0968.027
230 €
Ringlight Number of the lightpoints: 4 Length: 100 cm Inner diameter : 58 cm Adapterring
060.1045.027
250 €
503.0890.0
41 €
Ringlight Number of the lightpoints: 8 Length: 100 cm Inner diameter : 58 cm Adapterring
060.1041.027
365 €
503.0890.0
41 €
Ringlight Number of the lightpoints: continuous lightring
060.0823.027
415 €
503.0890.0
41 €
Focusing set I consisting of 1 focusing set and 1 adaptersleeve
003.0040.012
62 €
Focusing set II consisting of 2 focusing sets and 2 adaptersleeves
003.0040.009
82 €
Colour filterset I consisting of: 1 yellow filter, 1 green filter, 1 red filter, 1 blue filter and 1 adaptersleeve Focusing set I necessary
003.0040.014
82 €
003.0040.012
62 €
Colour filterset II consisting of: 2 yellow filters, 2 green filters, 2 red filters, 2 blue filters and 2 adaptersleeves Focusing set II necessary
003.0040.011
145 €
003.0040.009
82 €
Operating voltage: 110 V - 115 V / AC Operating voltage: 220 V - 230 V / AC upon request also available in 100 V, 200 V, 240 V Frequency: 50 / 60 Hz Power consumption: 160 W Electrical connection: Safety plug, safety class 1 Fuse: 0,8 A for 200 V-240 V, 1,6 AT for 100 V-110 V Lamp: mirror lamp 15 V / 150 W Lifetime: approx. 1000 hours Optic: 1 lens condenser with heat protection filter Colour temperature: 3200° K at full power Dimensions: 120 mm (H) x 150 mm (B) x 280 mm (D) Weight: approx. 3,5 kg Housing: plastic Brightness contorl: optomechanically Certification: CE Accessories: Mirror lamp 15 V / 150 W (spare) Lightguides
Adapterring
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 51
Code number 003.0040.013
Price 105 €
Polarising set II consisting of 2 focusing lenses, 2 adaptersleeves and 2 polarising filters
003.0040.010
200 €
Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 3 mm Adapter
060.0155.027
93 €
013.6006.0
21 €
Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 6 mm Adapter
060.0175.027
115 €
013.6003.0
21 €
Flexible lightguide Number of the arms: 1 Length: 100 cm Diameter active: 8 mm Adapter
060.0184.027
125 €
013.6004.0
21 €
Polarising set I consisting of 1 focusing lens, 1 adaptersleeve and polarising filter
Further lightguides upon request. Production of customized lightguides possible.
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 52
Cameras Digital USB-Cameras Code number 019.9999.167
Price 750 €
CMOS-Kamera UI-1240 SE 1/1,8" Chip, colour 1,3 MP resolution, 25 fps C-Mount connection IDS uEye Software (for Windows XP/Vista/7) USB-cable included
019.9999.175
930 €
CCD-Camara UI-2250 SE 1/2" chip, colour 2,0 MP resolution, 12 fps C-Mount connection IDS uEye Software (for Windows XP/Vista/7) USB-cable included
019.9999.169
1.890 €
CCD-Camera UI-2280 SE 2/3" chip, colour 5,0 MP resolution, 6 fps C-Mount connection IDS uEye Software (for Windows XP/Vista/7) USB-cable included
019.9999.171
2.750 €
019.9999. 175
890 €
CMOS-Camera UI-1465 LE 1/2" Chip, colour 3,1 MP resolution, 11fps C-Mount connection IDS uEye Software (for Windows XP/Vista/7) USB-cable included
Digital SLR-Cameras Canon 550D DSLR Kit with EF-S 18-55mm 1:3,5-5,6 IS lens (image stabilized) 18,0-megapixel Canon APS-C CMOS sensor Full-HD Video with variable frame rate
Contact information: Phone: +49 6441 2004-0 Fax: + 49 6441 2004-44 E-Mail:
[email protected]
Subject to change without notice Right reserved to modify technical data
Issue April 2011
Page 53