Preview only show first 10 pages with watermark. For full document please download

Primergy Bx620 S4 Server Blade User`s Guide

   EMBED


Share

Transcript

PRIMERGY BX620 S4 Server Blade User’s Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read this section. Chapter 1 Overview This chapter explains component names of this Server Blade as well as an overview of the software provided with this Server Blade. In addition, the workflow, from placing the server to starting the operation, is also described. Chapter 2 Checking before OS Installation This chapter explains the preparation on the server and cautions necessary before OS installation. Please read this chapter before starting installation. Chapter 3 OS Installation using ServerStart This chapter explains how to install the OS in the server using ServerStart. Chapter4 Manual OS Installation This chapter explains how to install the OS on the server without using ServerStart. Chapter5 Operations after OS Installation This chapter explains the operations to be performed after OS installation. Be sure to perform those operations before operating the server. Chapter 6 High Reliability Tools For stable PRIMERGY server operations, we recommend that high reliability tools be installed. This chapter explains the installation and necessary settings of high reliability tools. Chapter 7 Installing Internal Options This chapter explains how to install internal options on this Server Blade. Chapter 8 Hardware Configuration/Utilities This chapter explains how to make the environment settings necessary to operate the Server Blade. Chapter 9 Operation and Maintenance This chapter explains the maintenance to be performed after server operations start. 3 Appendix This appendix explains the specifications for the server and internal options. It also covers how to recycle the products. 1 Before Reading This Manual For Your Safety This manual contains important information, required to operate this product safely. Thoroughly review the information in this manual before using this product. Especially note the points under "Safety Precautions" provided with the Chassis or Server Blade, and only operate this product with a complete understanding of the material provided. This manual and "Safety Precautions" should be kept in an easy-to-access location for quick reference when using this product. Data Backup To protect data stored in this product (including basic software such as the operating system and application software), perform backup and other necessary operations. Note that data protection is not guaranteed when repairs are performed. It is the customer's responsibility to maintain backup copies in advance. In case of data loss, Fujitsu assumes no liability for data maintenance or restoration and damages that occur as a result of the data loss for any reason, except for items covered under warranty. High Safety This product is designed, developed and manufactured as contemplated for general use, including without limitation, general office use, personal use, household use, and ordinary industrial use, but is not designed, developed and manufactured as contemplated for use accompanying fatal risks or dangers that, unless extremely high safety is secured, could lead directly to death, personal injury, severe physical damage, or other loss (hereinafter "High Safety Required Use"), including without limitation, nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in weapon system. You shall not use this Product without securing the sufficient safety required for the High Safety Required Use. If you wish to use this product for High Safety Required Use, please consult with our sales representatives in charge before such use. Problems may occur with this product in the event of an instantaneous voltage drop of the power supply due to lightning, etc. To prevent an instantaneous voltage drop of the power supply, we recommend that you use an uninterruptible power supply system.  Trademarks Microsoft, Windows, and Windows Server are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries. Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark or registered trademark of Linus Torvalds in the United States and other countries. Red Hat and all Red Hat-based trademarks and logos are trademarks or registered trademarks of Red Hat, Inc. in the United States and other countries. Other product names used are trademarks or registered trademarks of their respective manufacturers. Other products are copyrights of their respective manufacturers. Copyright FUJITSU LIMITED 2008 Screen shot(s) reprinted with permission from Microsoft Corporation. 2 PRIMERGY BX620 S4 Server Blade User’s Guide Content of this manual This Server Blade cannot be installed on chassis other than PRIMERGY BX600 S2/BX600 S3. This manual explains about installing the Server Blade on a PRIMERGY BX600 S3 Chassis. If installing it on a PRIMERGY BX600 S2 chassis, the following restrictions are imposed. • Read "BX600 S2 Blade Server System Unit Hardware Guide" before use. (Refer to the Document & Tool CD provided with the chassis.) • Do not install on the chassis Server Blades slot 4 and slot 10. If installed on chassis Server Blades slot 4 and slot 10, the device may not operate correctly. • Four internal LAN ports out of six of this Server Blade cannot be used. • Do not install the Server Blade slot with 4 Gbit/s FC I/O Module (PG-FCD201) installed on BX600 S2 chassis. This will cause a failure. When installing a Server Blade with a FC expansion board installed on the BX600 S2 chassis, use the 4 Gbit/s FC I/O Module (PG-FCD102). • Management Blade firmware may be required to be updated. For information about the combination of supported firmware, refer to the Fujitsu PRIMERGY website (http://primergy.fujitsu.com), and download or update an appropriate firmware. If an appropriate firmware is not applied, this product may not operate properly. 3 Remarks  Warning descriptions Various symbols are used throughout this manual. These are used to emphasize important points for your safety and that of others. The following are the symbols and their meanings. Fully understand these symbols when reading this manual. Failure to observe this warning may cause serious injury or death, and/or destroy the system. Failure to observe this warning may lead to injury, destruction of the system, or loss of data. The following symbols are used indicate the type of warning or caution being described. A triangle mark emphasizes the urgency of the WARNING and CAUTION. Details are described next to the triangle. A barred circle ( circle. ) warns against certain actions (Do Not). Details are described next to the A black circle indicates actions that must be taken. Details are described next to the black circle.  Symbols Symbols used in this manual have the following meanings: Expressions Meaning These sections explain prohibited actions and points to note when using this device. Make sure to read these sections. These sections explain information needed to operate the hardware and software properly. Make sure to read these sections. → This mark indicates reference pages or manuals.  Key descriptions / Operations Keys are described by their representative characters instead of their exact key face appearance, as show below. E.g. [Ctrl] key, [Enter] key, [→] key, etc. The following indicate pressing several keys at once: E.g. [Ctrl] + [F3] key, [Shift] + [↑] key, etc.  DVD-ROM drive descriptions In this manual, a DVD-ROM drive is described as CD/DVD drive. 4 PRIMERGY BX620 S4 Server Blade User’s Guide  Entering commands (Keys) Command entries are displayed in the following way: • At each blank in a command line (as pointed out above), press the [Space] key once. • When using Windows, commands are not case sensitive. • CD/DVD drive names are shown as [CD/DVD drive]. Enter your drive name according to your environment. [CD/DVD drive]: \setup.exe  Screen shots and figures Screen shots and figures are used as visual aids throughout this manual. Windows, screens, and file names may vary depending on the OS, software, or configuration of the server used. Figures in this manual may not show cables that are actually connected for convenience of explanation.  Consecutive operations Consecutive operations are described by connecting them with "–". Example: Procedure of clicking the [Start] button, pointing to [All Programs], and clicking [Accessories] ↓ Click [Start] – [All Programs] – [Accessories].  Abbreviations The following expressions and abbreviations are used throughout this manual. table: Abbreviations of Product names Product names Expressions and abbreviations PRIMERGY BX600 This server or the server (Refers to the entire blade server.) PRIMERGY BX600 S3 Blade Server System Unit Chassis PRIMERGY BX620 S4 Server Blade BX620 S4 Server Blade or Server Blade PRIMERGY BX600 Switch Blade Cisco Catalyst Blade Switch 3040 Switch Blade GbE Pass-Thru Blade Network Blade FC Switch Blade FC Pass-Thru Blade PRIMERGY BX600 Management Blade Management Blade PRIMERGY SX650 Storage Blade Storage Blade 5 table: Abbreviations of Product names Product names Microsoft® Microsoft® Windows Server® 2008 Standard Server® Windows 2008 Standard without Hyper-V™ Microsoft® Windows Server® 2008 Enterprise Microsoft® ® Microsoft® ® Windows Server 2008 Enterprise without Hyper-V™ Expressions and abbreviations Windows Server 2008 Standard, Windows Server 2008 Standard (32bit), or Windows Server 2008 Standard (64-bit) Windows Server 2008 Enterprise, Windows Server 2008 Enterprise (32bit), or Windows Server 2008 Enterprise (64-bit) Windows Server 2003, Standard Edition Windows Server 2003, Standard Edition Microsoft® Windows Server® 2003, Enterprise Edition Windows Server 2003, Enterprise Edition Microsoft® Windows Server® 2003 R2, Standard Edition Microsoft® Windows Server® 2003 R2, Enterprise Edition Microsoft® Windows Server® 2003, Standard x64 Edition Microsoft® Windows Server® 2003, Enterprise x64 Edition Microsoft® Windows Server® 2003 R2, Standard x64 Edition Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition Windows Server 2008, Windows Server 2008 (32-bit), or Windows Server 2008 (64-bit) Windows Server 2003 Windows Server 2003 R2 Windows Windows Server 2003 x64 *1 Windows Server 2003 R2 x64 Microsoft® Windows® 2000 Server Windows 2000 Server Microsoft® Windows® Preinstallation Environment Windows PE Microsoft® Windows Vista® Business Windows Vista Microsoft® Windows® XP Professional Windows XP Professional Microsoft® Windows® 2000 Professional Windows 2000 Professional Microsoft® Windows Server® 2003 Service Pack Microsoft® Windows Server® 2003 x64 Service Pack Service Pack Red Hat Enterprise Linux ES (v.4 for x86) Red Hat Enterprise Linux ES (v.4 for EM64T) Red Hat Enterprise Linux AS (v.4 for x86) Red Hat Enterprise Linux AS (v.4 for EM64T) Linux Red Hat Enterprise Linux 5 (for x86) Red Hat Enterprise Linux 5 (for Intel64) *1: Unless otherwise specified, Windows Server 2003 can also mean Windows Server 2003 x64. 6 PRIMERGY BX620 S4 Server Blade User’s Guide Reference Information  Server Blade types Server Blade types are described as follows. table: Server Blade types Expression and abbreviation Diskless type Description Servers without an internal hard disk  Software manuals The software manual contains other reference information and cautions for ServerStart not described in this manual. Please read it before using ServerStart. The software manual is contained as a "README.TXT" file in the root folder on the PRIMERGY Startup Disc. Use a text editor to read it.  Latest information about software provided with this server For the latest information regarding ServerStart, ServerView and other software provided with this server, refer to the Fujitsu PRIMERGY website (http://primergy.fujitsu.com). Warning and Caution Labels Warning and caution labels are found on the server. Do not remove or stain these labels. 7 8 PRIMERGY BX620 S4 Server Blade User’s Guide Contents 1 Chapter 1 Overview 1.1 BX600 Blade Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 1.2 Supplied Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 1.2.1 Setup Support Tool - ServerStart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 1.2.2 High Reliability Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 1.2.3 Installing High Reliability Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 2 1.3 Component Names and Functions . . . . . . . . . . . . . . . . . . . . . . . 27 3 1.3.1 Front View of Server Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 1.3.2 Internal View of Server Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 1.3.3 Baseboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 1.4 Workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4 Chapter 2 Checking before OS Installation 2.1 Preparation on the Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 2.1.1 Installing Internal Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 2.1.2 Hardware Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 5 2.2 Selecting the Installation Method . . . . . . . . . . . . . . . . . . . . . . . . 39 2.2.1 Supported OS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 2.2.2 Installation Modes of ServerStart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 2.3 Precautions on Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 6 2.3.1 Installation Partition Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 2.3.2 Notes on Configuring RAID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 2.3.3 Notes on a Multiple LAN Adapter Configuration . . . . . . . . . . . . . . . . . . . .43 2.3.4 Cautions for Using ServerStart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 2.3.5 Onboard Controller and Expansion Cards Supported by ServerStart . . .45 2.3.6 Cautions for Manual Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 7 Chapter 3 OS Installation using ServerStart 8 3.1 Quick Installation Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 3.2 Expert Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 3.2.1 Starting Up the Expert Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 3.2.2 Disk Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 3.2.3 OS Installation Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 3.2.4 Application Wizard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 3.2.5 Starting OS Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 9 Chapter 4 Manual OS Installation 4.1 Creating Driver Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 9 4.1.1 Required Driver Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 4.1.2 How to Create Driver Disks [FloppyBuilder Function] . . . . . . . . . . . . . . . . 72 4.2 Starting Manual Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 4.2.1 Installing Windows Server 2008 (Full) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 4.2.2 Installing Windows Server 2008 (Server Core) . . . . . . . . . . . . . . . . . . . . . 79 4.2.3 Installing Windows Server 2003 x64 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 4.2.4 Installing Windows Server 2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 4.2.5 Installing Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 4.3 Installing the LAN Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 4.3.1 Installing the LAN Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 4.4 Installing the Fibre Channel Driver . . . . . . . . . . . . . . . . . . . . . . . 94 4.4.1 For Windows Server 2008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 4.4.2 For Windows Server 2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 4.5 Installing SAS RAID Ctrl Driver . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Chapter 5 Operations after OS Installation 5.1 Memory Dump/Paging File Setting . . . . . . . . . . . . . . . . . . . . . . 100 5.1.1 How to Obtain Memory Dump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 5.2 Creating Backup Data for System Recovery . . . . . . . . . . . . . . 107 5.2.1 Windows Server 2008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 5.2.2 Windows Server 2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 5.3 Storing the System Setting Information . . . . . . . . . . . . . . . . . . 110 5.3.1 How to Store the BIOS Information with Server Management Tools . . . 111 5.3.2 How to Recover the BIOS Information with Server Management Tools . 112 5.4 Creating Maintenance Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 5.4.1 Installing ServerStart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 5.4.2 Creating "Server Management Tools" Disk . . . . . . . . . . . . . . . . . . . . . . . 116 5.4.3 Creating a DOS Floppy Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 5.5 Notes Before Operating the Server . . . . . . . . . . . . . . . . . . . . . 117 5.5.1 Auto-run Function from CD/DVD Drives . . . . . . . . . . . . . . . . . . . . . . . . . 117 5.5.2 Drive Letter Assignment in Expert Mode . . . . . . . . . . . . . . . . . . . . . . . . . 117 5.5.3 Notes on Advanced Uninterruptible Power Supply (UPS) . . . . . . . . . . . 118 5.5.4 Using Network Startup (PXE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 5.5.5 Changing the system drive size (only for Windows Server 2008) . . . . . 119 5.5.6 Other Notes on Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 5.6 LAN Driver Advanced Setup [BACS] . . . . . . . . . . . . . . . . . . . . 123 5.6.1 BACS Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 5.6.2 Teaming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 5.6.3 VLAN Setup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 5.7 LAN Driver Advanced Setup [Intel® PROSet] . . . . . . . . . . . . . 151 5.7.1 Intel® PROSet Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 5.7.2 Notes on Referring to the Intel® PROSet Help Topics . . . . . . . . . . . . . . 152 5.7.3 Teaming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 10 PRIMERGY BX620 S4 Server Blade User’s Guide 5.7.4 VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .158 5.7.5 Local Address Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161 5.7.6 Jumbo Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .162 1 Chapter 6 High Reliability Tools 6.1 RAID Management Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 6.1.1 Before starting operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164 6.2 Server Monitoring Tool [ServerView] . . . . . . . . . . . . . . . . . . . . 165 6.2.1 Installing ServerView . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166 6.2.2 Setting Required after Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167 2 6.3 Maintenance Support Tool [HRM/server] . . . . . . . . . . . . . . . . . 168 6.3.1 Installing HRM/server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168 6.3.2 How to use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168 6.4 Solving Problems Early [DSNAP] . . . . . . . . . . . . . . . . . . . . . . . 169 6.4.1 Installing DSNAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 6.4.2 How to Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 Chapter 7 Installing Internal Options 3 4 7.1 Before Installing Internal Options . . . . . . . . . . . . . . . . . . . . . . . 172 7.2 Removing and Attaching the Top Cover . . . . . . . . . . . . . . . . . . 174 7.2.1 How to Remove the Top Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174 7.3 Installing a CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 7.3.1 Location of CPU Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176 7.3.2 Available CPUs and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177 7.3.3 How to Install a CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178 7.3.4 Defective CPU Disconnection Function . . . . . . . . . . . . . . . . . . . . . . . . .181 5 6 7.4 Installing Memory Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 7.4.1 Location of Memory Module Installation . . . . . . . . . . . . . . . . . . . . . . . . .183 7.4.2 Available Memory Modules and Notes . . . . . . . . . . . . . . . . . . . . . . . . . .183 7.4.3 How to Install/Remove Memory Module . . . . . . . . . . . . . . . . . . . . . . . . .186 7.4.4 Defective Memory Disconnection Function . . . . . . . . . . . . . . . . . . . . . .187 7 7.5 Installing an Expansion Card . . . . . . . . . . . . . . . . . . . . . . . . . . 188 8 7.5.1 Location of Expansion Card Installation . . . . . . . . . . . . . . . . . . . . . . . . .188 7.5.2 Available Expansion Card Slot Modules/Expansion Cards and Notes .189 7.5.3 How to Install an Expansion Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190 7.6 Installing an Expansion Board . . . . . . . . . . . . . . . . . . . . . . . . . 194 7.6.1 Location of Expansion Board Installation . . . . . . . . . . . . . . . . . . . . . . . .194 7.6.2 Available Expansion Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195 7.6.3 How to Install an Expansion Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195 7.7 Installing an Internal Hard Disk Unit . . . . . . . . . . . . . . . . . . . . 197 7.7.1 Location of Internal Hard Disk Units Installation . . . . . . . . . . . . . . . . . . .198 7.7.2 Available Internal Hard Disk Units and Notes . . . . . . . . . . . . . . . . . . . . .198 7.7.3 How to Install the Internal Hard Disk Unit . . . . . . . . . . . . . . . . . . . . . . . .199 11 9 7.8 BIOS Setting with Expansion Card Installed . . . . . . . . . . . . . . 201 7.9 Connection Examples of an External Option Device . . . . . . . 202 7.9.1 Connection of a Backup Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 7.9.2 Connection of Storage Blade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 Chapter 8 Hardware Configuration/Utilities 8.1 Switch Block Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 8.1.1 Switch Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 8.2 BIOS Setup Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 8.2.1 Starting and Exiting the BIOS Setup Utility . . . . . . . . . . . . . . . . . . . . . . . 205 8.2.2 Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 8.2.3 Advanced Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 8.2.4 Peripheral Configuration Submenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 8.2.5 PCI Configuration Submenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 8.2.6 CPU Configuration Submenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 8.2.7 Security Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 8.2.8 Server Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 8.2.9 ASR&R Submenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217 8.2.10 CPU Status Submenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 8.2.11 Memory Status Submenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 8.2.12 Console Redirection Submenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 8.2.13 System Information Submenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 8.2.14 Boot Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 8.2.15 Boot Device Priority Submenu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 8.2.16 Exit Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 Chapter 9 Operation and Maintenance 9.1 Daily Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228 9.1.1 Checking the Server Condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228 9.2 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 9.2.1 Hardware Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 9.2.2 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 9.2.3 Software Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 9.3 System Event Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 9.3.1 Server Management Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 9.3.2 Starting and Exiting Server Management Tools . . . . . . . . . . . . . . . . . . . 244 9.3.3 Viewing/Saving/Deleting the System Event Log . . . . . . . . . . . . . . . . . . 246 9.4 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 9.4.1 Hardware Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 9.4.2 Security against Unauthorized Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 9.4.3 Security When Disposing of the Server . . . . . . . . . . . . . . . . . . . . . . . . . 250 9.5 Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 9.5.1 Importance of Backups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 12 PRIMERGY BX620 S4 Server Blade User’s Guide 9.5.2 Backup Devices, Software and Their Operations . . . . . . . . . . . . . . . . . .251 9.6 Restoring the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 9.6.1 For Windows Server 2008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .254 9.6.2 For Windows Server 2003 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .256 9.7 Reinstalling the OS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 9.7.1 Checking before OS Reinstallation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257 1 9.8 Maintenance Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 9.8.1 Maintenance Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .258 9.8.2 Contacting Maintenance Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .259 9.9 Maintenance & Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260 9.9.1 Operations after Replacement of a SAS Module or an Expansion Card Slot Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .260 Appendix A Server Blade Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 B Specifications for Internal Options . . . . . . . . . . . . . . . . . . . . . 264 B.1 CPU Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .264 B.2 Memory Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .265 B.3 Internal Hard Disk Unit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .265 B.4 Expansion Card Slot Module Specifications . . . . . . . . . . . . . . . . . . . . . . .266 C External Floppy Disk Drive (USB) Notes on Usage . . . . . . . . 267 D About Switch Blade (PG-SW107) Connection . . . . . . . . . . . . . 268 E Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271 2 3 4 5 6 7 8 9 13 14 Chapter 1 Overview This chapter explains the component names of this Server Blade as well as an overview of the software provided with this Server Blade. In addition, the workflow, from placing the Server Blade to starting the operation, is also described. 1.1 1.2 1.3 1.4 BX600 Blade Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supplied Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Component Names and Functions . . . . . . . . . . . . . . . . . . Workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 20 27 32 15 Chapter 1 Overview 1.1 BX600 Blade Server This blade server has the following features.  High performance / High integration PRIMERGY BX600 is a blade server that consists of a Chassis and multiple blades. It is a sophisticated high-performance blade server that enables you to efficiently install a Server Blade, monitoring device, LAN switching hub, power supply unit, fan, fibre channels, and so on in a 7U (height: approx. 31 cm) Chassis due to its high-performance and highly-integrated design. The blade server consists of the following components: [Front] [Rear] Server Blade/Storage Blade Switch Blade/GbE Pass-Thru Blade, etc. Switch Blade/ GbE Pass-Thru Blade/ FC Pass-Thru Blade, etc. Power Supply Unit Management Blade Power Supply Unit  Chassis (or Case) The following blades can be installed on the 7U-size Chassis: • Server Blades (Max.10) • Storage Blades (Max. 5) • Network Blade (external connection device) (Max.4) • Management Blade (Monitoring device) (2 installed as standard) 16 PRIMERGY BX620 S4 Server Blade User’s Guide  BX620 S4 Server Blade This Server Blade contains a CPU, memory, and a hard disk in the unit (42 × 476 × 286mm).  Storage Blade This is a blade type storage subsystem in which up to 5 hard disks can be installed. Install the Storage Blade in the chassis' Server Blade slot, and connect to the SAS RAID Ctrl that is installed in the Server Blade to the left side of the Storage Blade using an exclusive cable.  Network Blade This is an option that can be connected to LAN port and Fibre Channel devices. Refer to each Network Blade manual for details about Network Blades that are not described in this manual. • Switch Blade This is a LAN switching hub that supports a Gigabit LAN. • Fibre Channel Switch Blade This is a Switch Blade that enables fibre channel connection. The Switch Blade supports a Brocade Fabric Operating System (Fabric OS) and is compatible with all SilkWorm products. • GbE Pass-Thru Blade The GbE Pass-Thru Blade is used to connect the internal LAN ports (including a LAN Expansion Board) in a Server Blade to the external LAN ports at a ratio of 1:1. • FC Pass-Thru Blade FC Pass-Thru Blade is used to connect between the ports of the Fibre Channel Expansion Board (optional) that is installed in the Server Blade and the external Fibre Channel ports at a ratio of 1:1.  Management Blade (monitoring device) This blade is used to monitor the power supply, fan, and temperature in each blade and the Chassis. It is equipped with a dedicated CPU, LAN, and serial ports. This blade is independent of the Server Blade, ensuring stable system operation. The Management Blade also enables you to remotely control and monitor each blade from a management terminal via a LAN or serial port.  High reliability  Redundant function This server enables a redundant configuration for fan, power supply unit (optional), and Management Blade. The Management Blade supports the standard redundant configuration in which one unit manages the entire system in the master mode and another one is on standby in the slave mode. In this configuration, if the master Management Blade causes a failure, the slave blade takes over management without interrupting system operations. 17 Chapter 1 Overview  Monitoring and remote operations using the Management Blade The Management Blade enables you to monitor blades and the power supply unit, fan, and temperature in the Chassis. You can also turn on the Chassis and Server Blades remotely from the management terminal via the Management Blade.  Compact design and scalability  Space-saving design The server, display device, keyboard, and external SCSI options fit in a 19-inch rack, which saves the installation space.  BX620 S4 Server Blade  High performance and space saving features The BX620 S4 Server Blade supports up to two Quad Core Intel® Xeon® processors or Dual Core Intel® Xeon® processors as well as a SAS (Serial Attached SCSI) interface and fibre channel interface (optional). Up to 10 Server Blades can be installed in the PRIMERGY BX600 S3 Blade Server System Unit depending on system configurations.  High-speed processing • Quad Core Intel® Xeon® Processors or Dual Core Intel® Xeon® Processors The server supports up to two Quad Core Intel® Xeon® processors or Dual Core Intel® Xeon® processors for high-speed data processing. A Quad Core processor functions as four physical CPUs, a Dual Core processor functions as two physical CPUs. A Quad Core Processor does the same work as four physical CPUs and a Dual Core Processor does the same work as two physical CPUs. • PCI-Express (x8) Expansion board slot is used. • A PCI-Express/PCI-X Expansion card slot is used. When the Expansion card slot module (PG-CS104) is installed, PCI-Express (x4) buses can be used. When the Expansion card slot module (PG-CS103) is installed, PCI-X buses with a maximum data transfer speed of 1.06Gbps can be used. • SAS When using a SAS interface in the onboard controller, the maximum data transmission rate is 3Gbps. • Server blade and LAN Network Blade are connected through the six LAN ports that has a high-speed data transfer capability (1Gbps). 18 PRIMERGY BX620 S4 Server Blade User’s Guide  High scalability This Server Blade has high-density functions, ensuring the configuration of a large-capacity and extensible system. • Up to 32 GB of memory can be installed for each Server Blade. • Up to two 2.5-inch internal hard disk units can be installed in each Server Blade. When using a Storage Blade, up to five more hard disks can be connected to the Server Blade. • Each Server Blade can be connected to the backup device via an external SCSI (can be connected via the SCSI card when the expansion card slot module (PG-CS103) is installed). • Using the Fibre Channel Expansion Board (optional), a fibre channel system (SAN) can be configured. • When the expansion card slot module (PG-CS103 or PG-CS104) is installed, network extension from an expansion card and connection to the backup device are enabled.  High reliability • You can specify a password so that only a specific person can use the Server Blade. • The server supports the Single Device Data Connection (SDDC) function using PC2-5300-compliant memory (DDR2 667 SDRAM) and the memory mirror function (depending on the memory configuration) to enable data recovery in the event of a memory error. • A storage system (RAID1) can be configured using an onboard SAS array controller. When installing SAS RAID Ctrl (MegaRAID SAS), a storage system (RAID0/RAID1/RAID1+0/ RAID5/RAID6) can be configured in a Storage Blade that is an external option. • The ServerView's Automatic Server Reconfiguration & Restart (ASR& R: automatic restart) function enables you to quickly recover a server error. • The ServerView action function enables you to view system event log (SEL) during OS operation. • High reliability tools offer stable system operation. For information about high reliability tools, refer to "1.2.2 High Reliability Tools" (pg.23). 19 Chapter 1 Overview 1.2 Supplied Software The following software is supplied together with the server. ServerStart supports setting up the system and high reliability tools prevent troubles while server system is running. 1.2.1 Setup Support Tool - ServerStart ServerStart is an initial setup support tool for PRIMERGY. It offers simple procedures for setup and proper installation for recommended drivers.  Setting up with ServerStart When performing the OS installation with ServerStart, drivers which are corresponding to the automatically recognized expansion cards will be installed by ServerStart. In addition, high reliability tools and array controller management tools are automatically installed. It prevents the related errors. It is recommended to perform the OS installation with using ServerStart. Not using ServerStart Complicated hardware settings such as RAID configuration User definition, access policies and network settings Manual settings for each item resulting in leading mistakes and taking time for server installation. Install & Setup Example: IP address settings, creation of user, registration of computer name, and etc. Using ServerStart Automatic RAID configuration Automatic installation of recommended drivers Automatic installation of high reliability tools are available. Auto setup Example: Automated operations such as OS installation. 20 ServerStart PRIMERGY BX620 S4 Server Blade User’s Guide  Some operations such as a license window and media replacements are required to be performed manually.  High reliability tools are software with comprehensive strength for stable system operation of the server management.  Merit with ServerStart setup  Network configuration ServerStart can configure a network on server installation. For details on available network patterns, refer to "Using ServerStart to Configure the Network".  Automatic driver installation This function installs the recommended drivers for such as automatically recognized expansion cards on the server installation. It is preventative for mismatch driver installations, such as previous version or incompatible drivers.  Automatic RAID configuration Without RAID utility, disk array can be configured by specifying a RAID type and number of hard disk unit. 21 Chapter 1 Overview  Intuitive user interface The intuitive user interface allows you to easily set the necessary information.  Main window When ServerStart starts up, the following window appears. The window and tool bar differ, depending on the mode.  Tool bar For the expert mode Ends ServerStart. Returns to the previous page. Returns to the main screen. Goes to the next page. Goes to one tier upper. Changes the size of icons. Resets the status function.  While the wizard is running, do not click the icon to move to the previous or next window or to upper tree level. To move to a different window, click the [Previous], [Up], or [Next] button at the bottom of the wizard window. 22 PRIMERGY BX620 S4 Server Blade User’s Guide  Wizard window Clicking a wizard displays a wizard window. Set each item in the wizard window. To move to a step in the next wizard window, click the operation button at the bottom of the window. Clicking [help] displays an explanation for setting the item. 1.2.2 High Reliability Tools High reliability tools provide comprehensive supports for stable system operations of the server. The following tools have individual management function through normal operations to restoration from errors: • Server monitoring tools • System diagnosis support tool • LAN driver advanced setup tools  Server monitoring tools The server monitoring tools monitor the hardware status and notify the event of an error when irregular status occurs.  Early detection of a server failure [ServerView] ServerView monitors the server status to protect important server resources. The server hardware keeps under observation all the time and a potential irregular status will be notified in timely manner when it is detected. A corrective action can be taken in early stage and eliminate the system error before growing a serious matter. 23 Chapter 1 Overview  For notes of security for ServerView, refer to "● Security" in Section "1.1.7 Note", ServerView User’s Guide.  Maintenance support tool [HRM/server] HRM/server performs the server maintenance operation promptly and surely to retain stable system operation.  Early detection of a disk problem [RAID Management Tool] RAID Management Tool monitors a configured disk array performance. When an event occurs, it leaves an event log in the event viewer's application logs. At the same time, a pop-up window indicates a hard disk failure, rebuild status, etc.  System diagnosis support tools The system diagnosis support tools boost device management in order to perform stable server operation.  Early solution to problems [DSNAP] DSNAP is a command line utility for collectively acquiring failure analysis information. Command line operation makes easy to set the configuration information of the system file and major registries, and collect the event log. When a problem occurs in your Windows Server 2003 system, DSNAP is used for a support engineer to understand your system software configuration and settings correctly and to promote research smoothly. Provide this with memory dump to your support engineer.  LAN driver advanced setup tools These tools set details on the LAN, including the use of teaming (load balance) function and VLAN configuration.  Broadcom Advanced Control Suite (BACS) BACS is a tool for setting details on the onboard LAN.  Intel® PROSet Intel® PROSet is a tool for setting details on the LAN card in case such as using teaming function between LAN cards or onboard LAN and LAN card, and configuring a VLAN with LAN card. 24 PRIMERGY BX620 S4 Server Blade User’s Guide 1.2.3 Installing High Reliability Tools Collective installation of all high reliability tools, provided with PRIMERGY, may be made by specifying them in "Application Wizard". The following high reliability tools are installed with ServerStart. table: High reliability tools installation ServerStart installation Quick Installation mode Expert mode RAID Management Tool / ServerView Console (for Apache) I S RAID Management Tool / ServerView Console (for IIS) M N I I I N High reliability tool ServerView Agent *1 HRM/server DSNAP Broadcom Advanced Control Suite (BACS) Intel® PROSet *2 *2 I S I I I I I: Installed automatically N: Installed if selected (Not selected by default) S: Installed if selected (Selected by default) M: Install manually *1: For Windows Server 2003, ServerView Agent is not displayed in the menu. *2: Not supported in Windows Server 2008 Server Core installation.  Linux do not support batch installation with ServerStart.  ServerView is required configuration after installation even when the high reliability tools have been installed at once with ServerStart. Refer to "Chapter 6 High Reliability Tools" (pg.163).  When using ServerStart to install the OS, RAID Management Tool and ServerView Console are installed together. These cannot be selected individually.  To use all functions of ServerView, "Java2 Runtime Environment Standard Edition" and "Web server" are required. When using ServerStart to install the OS, "Java2 Runtime Environment Standard Edition" is installed automatically. For Web server, you can use either of the following by selecting a menu. • ServerView Console (for Apache) Install ServerView Web-Server (Web server for ServerView, Apache for Win32 base) and install ServerView configuring to use this Web server. • ServerView Console (for IIS) Install Microsoft Internet Information Server (IIS) supplied with Windows separately. ServerView is installed with the setting to operate using IIS installed on the system. 25 Chapter 1 Overview  When IIS is not found in the system, ServerView Web-Server is installed even if "ServerView Console (for IIS)" is selected. ServerView Console (for Apache) is selected by default. To install ServerView Console (for IIS), select "RAID Management Tool / ServerView Console (for IIS)". If "RAID Management Tool / ServerView Console (for IIS)" is selected, ServerView Console (for Apache) is not installed. ServerView Console (for IIS) cannot be installed in Quick installation mode. For Windows Server 2008, ServerView Console (for IIS) cannot be installed.  For Windows Server 2003, it is not possible to release both the ServerView Console (for IIS) and the ServerView Console (for Apache). However, it is possible for Windows Server 2008. In Windows Server 2008 Server Core installation environment, ServerView Console (for Apache) is not supported.  Intel® PROSet will be installed only when an optional LAN card is installed properly and the driver is applied correctly.  If the OS is installed on other than drive C using ServerStart, Intel® PROSet will not be installed. In this case, install Intel® PROSet manually. For details, refer to "5.7.1 Intel® PROSet Installation" (pg.151). 26 PRIMERGY BX620 S4 Server Blade User’s Guide 1.3 Component Names and Functions This section explains the component names and functions of the Server Blade. 1.3.1 Front View of Server Blade c d e f g h i j b a k a Release latch This latch is used when installing/removing a Server Blade. b 2.5-inch storage bay Install the hard disk unit. Up to two hard disk units can be installed in this Server Blade. c Hard disk status LED Indicates the state of the internal hard disk unit installed where the LED is located. The meanings of each LED is as follows. • Hard disk access LED (Left) This LED lights green when data is being written to or read from the hard disk. 27 Chapter 1 Overview • Hard disk status LED (Right) This LED lights or blinks depending on the hard disk status described below. table: Hard disk status LED LED status Description Off Normal mode Lights amber Error detected in the hard disk Flashes amber Displaying the running hard disk using SAS BIOS Utility Flickers amber Rebuilding d Server blade power LED ( ) It is lit or blinks depending on the Server Blade power status as follows. table: Server blade power LED LED status Description Off The power is not supplied to the Server Blades. (The Chassis power is not turned on.) Lights green The power is turned on. Lights amber The power is turned off. (Standby) Blinks green Blinks when an error is detected in the Server Blade or the Server Blade identification function is used while the power is turned on. If an error occurs, contact an office listed in the "Contact Information" of "Start Guide" or device administrator. Blinks amber Blinks when an error is detected in the Server Blade or the Server Blade identification function is used while the power is turned off. If an error occurs, contact an office listed in the "Contact Information" of "Start Guide" or device administrator. Blinks green-amber Standby mode. (ACPI function) The Server Blade does not support this mode. e Server blade power switch Press this switch to turn the Server Blade on. For the procedure to turn the Server Blade on/off, refer to the "BX600 S3 Blade Server System Unit Hardware Guide".  When the hard disk access display LED lights, do not turn off the power. Data in the hard disk may be damaged. f KVM select LED ( ) It is lit or blinks depending on the KVM status as follows. table: KVM select LED LED status 28 Description Off KVM is not selected. Lights green KVM is selected. Blinks amber Blinks when a BMC *1 error was detected without KVM selected, or when the maximum installable number for the Server Blades was exceeded. In this case, contact an office listed in the "Contact Information" of "Start Guide" or device administrator. PRIMERGY BX620 S4 Server Blade User’s Guide table: KVM select LED LED status Blinks green-amber Description *1 error was detected with KVM selected, or when the Blinks when a BMC maximum installable number for the Server Blades was exceeded. In this case, contact an office listed in the "Contact Information" of "Start Guide" or device administrator. *1:BMC (Baseboard Management Controller): micro controller which manages temperature, voltage sensor, etc. on the baseboard g KVM select switch Pressing this switch enables operation of the display, keyboard, and mouse, which are connected to the KVM module, in the Server Blade. When this switch is pressed twice for 5 seconds or longer, the maintenance switch function (NMI function) can be used.  When the following operations are performed, the same function as the maintenance switch can be used. 1. Press the KVM select switch for 5 seconds or longer. The KVM select LED is lit. 2. Press the KVM select switch again within 3 seconds, and wait for 5 seconds or longer. The NMI function can be used. h Expansion board active link display LED ( I/O ) This LED is on, depending on the expansion board status as follows. table: Expansion board active link display LED LED status Lights green Description One of two ports is establishing a link. i LAN active link display LED ( ) It is lit or blinks depending on the LAN status as follows. table: LAN active link display LED LED status Description Lights green One of six LAN ports is establishing a link. Blinks green Data is currently transferred or received through a LAN. j Display / USB extension connector ( ) Display device or USB-connected peripheral devices are connected using a Display/USB Extension Cable. k Expansion Card Slot The SAS controller with array function is installed standardly. When the optional expansion card slot module is installed, a PCI-Express or PCI-X expansion card can be installed. The type of card that can be installed varies depending on the type of the expansion card slot module. 29 Chapter 1 Overview 1.3.2 Internal View of Server Blade [Front] [Rear] a b c d e g f a Expansion Card Slot b Chassis connector Various interface signals are connected to the chassis connector. c Expansion board slot Install an expansion board. d Port 1 for I/O expansion board and port 2 for I/O expansion board Ports (Max. 2 ports) for I/O expansion board (Fibre Channel Expansion Board/LAN Expansion Board). These ports are connected to the Network Blade (NET 3/4) on the rear of the Chassis via the mid plane. e Memory slots A memory module (Add-on RAM module) is installed in the memory slot. f CPU sockets Install the CPU. One socket is installed by default. Up to two sockets can be installed. g 2.5-inch storage bay 30 PRIMERGY BX620 S4 Server Blade User’s Guide 1.3.3 Baseboard a [Front] b [Rear] g f e d c a Expansion board slot b Switch block For details about switch settings, refer to "8.1 Switch Block Settings" (pg.204). c Memory slots d CPU sockets e SAS connector 1 This connector is connected to 2.5-inch storage bay 1. f SAS connector 2 This connector is connected to 2.5-inch storage bay 2. g Connector for expansion card slot module When an expansion card slot module is installed, this connector is connected to the expansion card slot module. 31 Chapter 1 Overview 1.4 Workflow Use the following workflow from server installation to start of operation. Installing the server Referring to "Safety Precautions" and "Start Guide", install the server to a suitable place. Preparing the server - Install Internal options - Set hardware Referring to "BX600 S3 Blade Server System Unit Hardware Guide", the manual of the network blade to use, "BX600 Management Blade Hardware Guide" and "2.1 Preparation on the server", "Chapter 7 Installing Internal Options", "Chapter 8 Hardware Configuration/Utilities" in this manual. Selecting the installation method Referring to "2.2 Selecting the Installation Method", decide what installation method to use. ServerStart, a software product that enables everything from OS installation/setup to the installation of high reliability tools to be performed in one operation, can be used in this server. It is recommended that ServerStart is used to perform installation. Checking precautions on installation Before installing the OS, check the precautions on installation by referring to "2.3 Precautions on Installation". OS installation Using ServerStart Manual installation Referring to "Chapter 3 OS Installation Using ServerStart", perform OS installation. Referring to "Chapter 4 Manual OS Installation", perform OS installation. Installing Internal options Referring to "Chapter 7 Installing Internal Options", install the Internal options. Procedures before operation Before operating the server, refer to "Chapter 5 Operations after OS Installation". High reliability tool installation When the OS is installed manually, it is necessary to install high reliability tools. ServerView requires settings before server operation. For installation method and details about each high reliability tool, refer to "Chapter 6 High Reliability Tools". Start operations 32 Chapter 2 Checking before OS Installation This chapter explains the preparation on the server and cautions necessary before OS installation. Please read this chapter before starting installation. 2.1 Preparation on the Server . . . . . . . . . . . . . . . . . . . . . . . . 2.2 Selecting the Installation Method . . . . . . . . . . . . . . . . . . . 2.3 Precautions on Installation . . . . . . . . . . . . . . . . . . . . . . . . 34 39 42 33 Chapter 2 Checking before OS Installation 2.1 Preparation on the Server Before starting installation, install internal options to the server and perform necessary hardware settings. 2.1.1 Installing Internal Options Before installing internal options, refer to each option manual and be sure to read the notes. Install the internal options in the Server Blades, and install the blades and options in the Chassis. For details on the internal options, refer to the following: • Installing internal options to Server Blades → "Chapter 7 Installing Internal Options" (pg.171) • Installing blades, Power Supply Unit, and Fan Unit in the Chassis → "Chapter 4 Installing Options" in "BX600 S3 Blade Server System Unit Hardware Guide"  Cautions for installing a Storage Blade If an array has already been configured in the internal hard disk unit that is installed in the Storage Blade, delete the array configuration when installing the OS. Set an array configuration again after OS installation.  Cautions for installing an external storage system When installing an external storage system such as the ETERNUS series in the Chassis, make sure to turn the external storage system power on after the OS installation has completed. Make sure the power is not turned on when installing the OS by taking precautions such as disconnecting the power cable.  LAN cable Be sure to connect the LAN cable when the server is not connected to the Internet.  Connecting to the Internet during setup can cause security problems. Do not connect to the Internet until the setup completes. If the OS is installed or applications are automatically installed without connecting the LAN cable, an error may be recorded in the event viewer after the setup process finishes.  Cautions for installing an expansion card When using an expansion card, read the notes on the expansion card. 34 PRIMERGY BX620 S4 Server Blade User’s Guide  USB floppy disk drive and USB CD/DVD drive To use the PRIMERGY Startup Disc, connect the USB floppy disk drive and USB CD/DVD drive to the Server Blade to be installed. Use the Display/USB Extension Cable to connect them before turning the power on the Server Blade. It is strongly recommended that only products listed on the Fujitsu PRIMERGY website (http:// primergy.fujitsu.com) are connected to the server.  Do not install or remove USB devices unless specified in procedures.  Cautions for installing a memory module The available memory size of the server depends on the OS. Furthermore, since the server uses part of the memory as PCI resources, the maximum available size is limited. The following shows the maximum installable size and the maximum available size. table: Maximum Installable Size and Maximum Available Size OS Installed memory size Available memory size Windows Server 2008 Standard (32-bit) Windows Server 2003, Standard Edition Windows Server 2003 R2, Standard Edition Up to 3GB Same as the installed memory size 3GB to 4GB Depends on the [Execute Disable Bit] setting in the [CPU Configuration] submenu under the Advanced menu of the BIOS Setup Utility. • Disabled: 3GB*1 • Enabled: Same as the installed memory size Windows Server 2008 Enterprise (32-bit) Up to3GB Same as the installed memory size Windows Server 2003, Enterprise Edition*2 3GB to installed Depends on the [Execute Disable Bit] setting in the [CPU Configuration] submenu under the Advanced menu of the BIOS Setup Utility. • Disabled: 3GB*1 • Enabled: Same as the installed memory size Windows Server 2003 R2, Enterprise Edition*2 Windows Server 2008 Standard (64-bit) Windows Server 2008 Enterprise (64-bit) Windows Server 2003, Standard x64 Edition*2 memory size*3 Installed Same as the installed memory size memory size*3 Windows Server 2003, Enterprise x64 Edition*2 Windows Server 2003 R2, Standard x64 Edition*2 Windows Server 2003 R2, Enterprise x64 Edition*2 Linux *1: The installed memory size can become usable memory by setting PAE on each OS. For the procedure for setting PAE on each OS, refer to the Microsoft website. *2: When installing 8GB or more of memory in a server, apply the hotfix module (KB907892) provided from Microsoft. The hotfix module is also stored in the ServerStart CD/DVD. *3: The usable memory varies depending on the OS that is used. 35 Chapter 2 Checking before OS Installation  Cautions applicable when the OS is Windows Server 2003 R2 / Windows Server 2003, Standard Edition / Windows Server 2003, Enterprise Edition When installing 4GB or more of memory in a server, the /PAE option in the "Boot.ini" file must be specified. For the procedure for editing the "Boot.ini" file, refer to the Microsoft website.  The "Boot.ini" file is an important file for the system. If the file is edited improperly, the system may not start up. Edit it carefully. 2.1.2 Hardware Settings Before starting installation, set necessary hardware, such as the BIOS Setup Utility.  Switch block settings Perform and confirm physical setting for the switch block of the Server Blade. An improper setting will cause the Server Blade not to run or malfunction. "8.1 Switch Block Settings" (pg.204)  BIOS Setup Utility The BIOS Setup Utility must be set in the following cases. For details on how to set the BIOS Setup Utility, refer to "8.2 BIOS Setup Utility" (pg.205).  The contents set with the BIOS Setup Utility are recorded in CMOS and NVRAM in the Server Blade. This CMOS stores information with the built-in battery. When a setup message is displayed during POST even after setup was performed normally, the setup contents may not be stored in CMOS. The built-in battery may be drained. Contact an office listed in the "Contact Information" of the "Start Guide".  Do not modify the item indicated "Unchangeable" in "8.2 BIOS Setup Utility" (pg.205). The device may not run normally.  Changing the boot drive To change the boot drive, start up the BIOS Setup Utility, and set the boot drive in the [Boot Device Priority] submenu. "8.2.15 Boot Device Priority Submenu" (pg.225)  Specifying a password To specify a password, start the BIOS Setup Utility, select "Change Supervisor Password" or "Change User Password", and enter your password. "8.2.7 Security Menu" (pg.214) 36 PRIMERGY BX620 S4 Server Blade User’s Guide  Setting the time synchronization function with the Management Blade To set the time synchronization function with the Management Blade, select "Sync RTC with Mgnt. Blade" in the [Main] menu on the BIOS Setup Utility, and specify the time synchronization function. "8.2.2 Main Menu" (pg.208)  Using an USB CD/DVD drive (change of device priority sequence) When using the USB CD/DVD drive, change the device priority sequence in the [Boot] menu of the BIOS Setup Utility. For more details about changing the boot drive, refer to "8.2.15 Boot Device Priority Submenu" (pg.225). 1st Boot Device 2nd Boot Device 3rd Boot Device 4th Boot Device 5th Boot Device [Y-E USB-FDU] [CENERIC CDR****] [#520 ID00 LUN0 ***] (When an expansion card slot module is not installed) [IBA CE Slot **** v] [IBA CE Slot **** v]  Booting the Server Blade with PXE Before Booting the Server Blade with PXE, use the following procedures to enable network startup (PXE). In addition, check the MAC address.  When booting the Server Blade with PXE, turn on the Server Blade power one minute or more after the main power of the Chassis was turned on. Turning on the Server Blade power just after the main power was turned on may cause PXE not to boot due to the Switch Blade not having been started.  The PXE boot function is not available for the LAN port of the 1 Gbit/s Ethernet I/O Module. 1 Take the following steps in the BIOS Setup Utility. Set PXE (IBA CE slot nnnn v) to the highest level in the boot priority sequence. For more details about changing the boot drive, refer to "8.2.15 Boot Device Priority Submenu" (pg.225).  The boot priority sequence can be changed from Web UI or CLI for the Management Blade. Refer to "BX600 Management Blade Hardware Guide". 2 Check the MAC address. After BIOS setup, start up the server from the network. After POST was completed, the MAC address is displayed as shown below. CLIENT MAC ADDR: ** ** ** ** ** ** 3 Turn off the server.  You can confirm that the server is turned off using "Deployment Parameter" for Web UI and CLI, and "Server Blade MAC Address Table" for CLI of the Management Blades. For details, refer to "BX600 Management Blade Hardware Guide". 37 Chapter 2 Checking before OS Installation  When installing Windows Server 2008 (64-bit) using ServerStart When installing Windows Server 2008 (64-bit) using ServerStart, and when saving the configuration file to a floppy disk, the boot priority must be changed as follows using the BIOS Setup Utility at ServerStart startup.  If the boot priority is not changed, the automatic installation stops in the middle. Make sure to change it. 1 Turn the Server Blade on, and start the BIOS Setup Utility. "8.2.1 Starting and Exiting the BIOS Setup Utility" (pg.205) 2 Select the [Main] menu – [Boot] submenu, and press the [Enter] key. The [Boot Settings] window appears. 3 Select [Boot Device Priority], and press the [Enter] key. The [Boot Device Priority] submenu appears. 4 Set the Boot device to put [Hard Disk Drives] before [Removable Drives]. Set it as follows. [Removable Drives] and [CD/DVD Drives] are displayed when connecting the USB device. 1 CD/DVD Drives 2 Hard Disk Drives 3 Removable Drives 5 Exit the BIOS Setup Utility, and turn the server's power off. 38 PRIMERGY BX620 S4 Server Blade User’s Guide 2.2 Selecting the Installation Method When installing the OS for the first time, there are multiple installation methods. Refer to the following to decide on the method. What OS will you use? Linux For the use of Linux, refer to the Fujitsu PRIMERGY website (http://primergy.fujitsu.com). Windows Server 2008 Windows Server 2008 x64 Windows Server 2003 R2 x64 Windows Server 2003 x64 Windows Server 2003 R2 Windows Server 2003 No Will you use ServerStart? Installation is performed manually. Refer to "4.2 Starting Manual Installation" and perform installation. Yes Do you want to use the default settings? No Refer to "3.2 Expert Mode" and perform installation. * If you follow the wizard, setup will be performed correctly. Yes Refer to "3.1 Quick Installation Mode" and begin the install. By setting the minimum settings the install will start quickly. 39 Chapter 2 Checking before OS Installation 2.2.1 Supported OS The supported OS varies depending on the ServerStart version.  ServerStart V7.804 For ServerStart V7.804, the following OSes can be installed. • Microsoft® Windows Server® 2008 Standard • Microsoft® Windows Server® 2008 Enterprise • Microsoft® Windows Server® 2008 Standard without Hyper-V™ • Microsoft® Windows Server® 2008 Enterprise without Hyper-V™  ServerStart V6.711 For ServerStart V6.711, the following OSes can be installed. • Microsoft® Windows Server® 2003, Standard Edition • Microsoft® Windows Server® 2003, Enterprise Edition • Microsoft® Windows Server® 2003, Standard x64 Edition • Microsoft® Windows Server® 2003, Enterprise x64 Edition • Microsoft® Windows Server® 2003 R2, Standard Edition • Microsoft® Windows Server® 2003 R2, Enterprise Edition • Microsoft® Windows Server® 2003 R2, Standard x64 Edition • Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition  ServerStart does not support OS installation of Linux.  Any of unsupported OS can not be installed. 40 PRIMERGY BX620 S4 Server Blade User’s Guide 2.2.2 Installation Modes of ServerStart  Quick installation mode This mode completes the OS installation by executing plain settings. Select this mode when you want to install the OS quickly and simply. When installing Windows Server 2008 in Quick installation mode, perform full installation. To install while maintaining the established RAID environment, the quick installation mode must be selected to install the OS. Select [Logical Disk0] in the [Select the Boot Controller and Boot Disk] window and install the OS.  Expert mode In this mode, start up Disk Manager and format the partition where your OS is installed prior to installation of the OS. Select the expert mode only when installing the OS while maintaining the existing partitions. Windows Server 2008 cannot be installed in Expert mode. Also, when using ServerStart while maintaining the existing partitions, start up Disk Manager, format an installation partition and install the OS. 41 Chapter 2 Checking before OS Installation 2.3 Precautions on Installation Read the following notes before starting OS installation. 2.3.1 Installation Partition Size For installation using ServerStart, the installation partition size can be set as follows. • Maximum size: 2TB • Minimum size: 2200MB  Notes • When you want to set the OS and BOOT partitions in different partitions, specify the partition size directly. • In either of the following cases, specify a partition size up to 2TB. • When the same partition is specified as the OS and BOOT partitions • When different partitions are specified as the OS and BOOT partitions • The OS cannot be installed in a partition larger than 2TB.  The BOOT partition is a partition for booting. Minimum information that is necessary for booting such as "ntldr" is set. The OS partition is a partition for installing the OS. 2.3.2 Notes on Configuring RAID When configuring RAID, check the following beforehand.  Internal hard disk unit • Up to two internal hard disk units can be installed in the Server Blade, and up to five internal hard disk units can be installed in the Storage Blade. • Internal hard disk units that can be installed in the Server Blade or Storage Blade vary depending on the RAID level. For details, refer to the manuals in the Array Controller Document & Tool CD. • Be sure to use hard disk units of the same model and with the same capacity. 42 PRIMERGY BX620 S4 Server Blade User’s Guide  RAID configuration Array controllers to be used vary. For RAID configuration, refer to the respective manuals.  When using an onboard SAS Ctrl (Integrated Mirroring SAS) Configure RAID with an internal hard disk unit which is connected to a SAS Ctrl. The array controller to be employed is "Integrated Mirroring SAS" and available RAID level is "RAID1" only. For details, refer to "Integrated Mirroring SAS User's Guide" in the Array Controller Document & Tool CD.  When using a SAS RAID Ctrl (MegaRAID SAS) Configure RAID with a Storage Blade which is connected to a SAS RAID Ctrl. The array controller to be employed is "MegaRAID SAS" and available RAID level is "RAID0 / RAID1/ RAID1+0 / RAID5/ RAID6". For details, refer to "MegaRAID SAS User's Guide" in the Array Controller Document & Tool CD. 2.3.3 Notes on a Multiple LAN Adapter Configuration Using the OS installation wizard of ServerStart, you can configure multiple LAN adapters (network adapters) on the system. However, there are the following limitations.  Adapter numbers To configure multiple LAN adapters (PG-2861L/PG-LND201, etc.), select the adapter numbers in order of Adapter 1 and Adapter 2, and enter settings for each adapter. Note that the order of adapter numbers is not necessarily the same as the onboard LAN port numbers. This means that the setting for Adapter 1 is not always applied to LAN port 1 of the onboard LAN. After installing the OS, check the LAN adapters to make sure that they are configured as intended. 2.3.4 Cautions for Using ServerStart Observe the cautions described below when the OS installation is performed with ServerStart.  Operating ServerStart Mainly, a mouse is used for ServerStart operations. In some cases, operation with the [Tab] key or cursor are not available. Be sure to use a mouse while operating ServerStart. 43 Chapter 2 Checking before OS Installation  Configuration file (SerStartBatch.ini) A configuration file stores the server setup and client information configured in ServerStart. To create a configuration file, use the ServerStart floppy disk. Store only one file on each floppy disk. Do not set the ServerStart floppy disk to the write-protected state. You can use any name for the configuration file. However, the file must be installed in the server as "SerStartBatch.ini". When installing the configuration file, make sure to save it as "SerStartBatch.ini" on the ServerStart floppy disk. Start up ServerStart, insert the ServerStart floppy disk containing "SerStartBatch.ini", and click [Start] to install the server  Ejecting PRIMERGY Startup Disc Do not eject PRIMERGY Startup Disc while ServerStart is running. If the PRIMERGY Startup Disc is ejected and inserted again, ServerStart starts up in multiple windows, and settings you have made may be lost.  Exiting ServerStart After operation in the expert mode, exiting ServerStart restarts the system. Remove discs from the floppy disk and CD/DVD drives and click [OK]. When the display on the screen disappears, turn off the system.  License for use of system for ServerStart "License for Use of System for ServerStart" linked from the ServerStart startup window is a license for use of Windows PE contained in ServerStart of the PRIMERGY Startup Disc. Windows PE for starting up ServerStart can be only used for installing Windows Server 2008, Windows Server 2003 R2, and Windows Server 2003, provided under a separate legal license.  Display of onboard LAN Display of an onboard LAN on your OS is as below when OS installation performs with ServerStart. table: Display of Onboard LAN LAN Port Property on My Network LAN Device Name Onboard LAN Local Area Connection BroadcomNetXtreme Gigabit Ethernet  Adapter numbers For ServerStart, onboard multiple LAN adapters (network adapter) may be configured on OS installation wizard. To configure multiple LAN cards, select the adapter numbers in order of Adapter 1 and Adapter 2, and enter settings for each adapter. Note that the order of adapter numbers is not necessarily the same as the order of slots for the installed LAN adapters. This means that the setting for Adapter 1 is not always applied to the onboard LAN. After installing the OS, check the LAN adapters to make sure that they are configured as intended.  Setting up the printer ServerStart does not support setup of printers. Perform installation after setup is completed. 44 PRIMERGY BX620 S4 Server Blade User’s Guide  Caution when installing the LAN expansion board (PG-LND201) When installing an OS using ServerStart in a device which contains a LAN expansion board (PGLND201), the Connection Name and IP address settings that are set in the network protocol screen of the OS installation wizard will not be set. Allocate the Connection Name and IP address in the LAN expansion board (PG-LND201) manually after the OS installation. 2.3.5 Onboard Controller and Expansion Cards Supported by ServerStart ServerStart supports automatic driver installation for the following expansion cards. table: Automatic Expansion Card Driver Installation Name Model Bus Onboard SAS (array) controller - PCI-E Onboard LAN - PCI-E Onboard VGA - PCI SAS RAID Ctrl PG-248EL PCI-E Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp PG-2861L PCI-E SCSI Ctrl U160 lp PG-1301L PCI-X 1Gbit/s Ethernet I/O Module PG-LND201 PCI-E 2Gbit/s FC I/O Module PG-FCD102 PCI-X 4Gbit/s FC I/O Module PG-FCD201 PCI-E 2.3.6 Cautions for Manual Installation  Checking onboard array controller setting Disk array configuration on the onboard array controller must be completed before the OS is installed. For more details, refer to the manual in the Array Controller Document & Tool CD.  Free space required for installation The partition where the OS is installed must have enough free space for obtaining memory dump. For more details, refer to "5.1 Memory Dump/Paging File Setting" (pg.100).  Cautions on restarting In the course of installation, a message appears to indicate that the setup program restarts. Wait until it restarts. For more details on background operations, refer to the manual in the Array Controller Document & Tool CD. 45 Chapter 2 Checking before OS Installation 46 Chapter 3 OS Installation using ServerStart This chapter explains how to install the OS in the server using ServerStart. 3.1 Quick Installation Mode . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 Expert Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 55 47 Chapter 3 OS Installation using ServerStart 3.1 Quick Installation Mode In this quick installation mode, the OS is installed after configuring minimum required settings. To install the OS quickly and easily, use the quick installation mode.  When installing Windows Server 2008, perform "Full installation".  When installing Windows Server 2008 (64-bit) using ServerStart, and when saving the configuration file to a floppy disk, the boot priority must be changed as follows using the BIOS Setup Utility at ServerStart startup. For the procedure for changing the boot priority, refer to " When installing Windows Server 2008 (64-bit) using ServerStart" (pg.38) 1 Connect the USB CD/DVD drive and USB floppy disk drive to the Server Blade. Use the Display/USB Extension Cable to connect the USB CD/DVD drive and USB floppy disk drive. For more information on the connection procedure, refer to "Start Guide". 2 Turn on the server and insert PRIMERGY Startup Disc immediately.  When installing Windows Server 2003, use "PRIMERGY Startup Disc". When installing Windows Server 2008, use "PRIMERGY Startup Disc for Windows Server 2008". ServerStart starts up. The select-media window for the configuration file appears. 48 PRIMERGY BX620 S4 Server Blade User’s Guide 3 Insert the ServerStart floppy disk. Make sure that "on local drive (floppy/USB stick)" and "A:" are selected and click [Continue].  Set the ServerStart floppy disk in the write-enabled state.  When installing the OS without using the ServerStart floppy disk, select [No status backup], and click [Next]. [No status backup] cannot be selected in the following cases. •When configuring RAID using ServerStart •When installing Windows Server 2003 x64 •When installing Windows Server 2008 The [Initialization of ServerStart core running] window appears and the ServerStart initialization process starts. Depending on hardware configuration, this process may take a few minutes. After completion, the license agreement window appears. 49 Chapter 3 OS Installation using ServerStart 4 Click [Accept]. The [Welcome to ServerStart] window appears. 5 Select [Quick Installation] and click [Next]. The [Select the Boot Controller and Boot Disk] window appears. 50 PRIMERGY BX620 S4 Server Blade User’s Guide 6 Set configuration of the RAID and disks and click [Next]. To install the OS while maintaining the established RAID environment Select [Logical Disk 0] and specify partition size to be created. One partition can be created. Select [Logical Disk 0] even if the RAID is not required to be created. To configure RAID Select [create new RAID array with one partition] and specify the RAID level to be configured and the size of the partition. All existing RAID will be deleted. Also, only one partition can be created.  When [Auto] is selected, the RAID is configured with the following levels, depending on the number of the installed disk units. •When two hard disk units are installed: RAID1 •When three hard disk units are installed: RAID5 •When more than three hard disk units are installed: RAID5 with hot spare function  The configurations of the created partitions are as follows. •Volume label: system •File system: NTFS •Partition configuration: Boot/OS The [Please select the OS to install] window appears. 51 Chapter 3 OS Installation using ServerStart 7 Select the OS to be installed and click [Next]. The [Configure your unattended Windows Installation] window appears. 8 Set the items and click [Next]. The [Summary] window appears. 9 Confirm the settings and click [Start Installation]. 10 Click [Start now]. Installation starts. 1. If a message prompts you to insert Array Controller Document & Tool CD, insert the CD and click [OK]. 2. For Windows Server 2003 x64, a message appears and prompts you to insert PRIMERGY Startup Disc Win64 and restart the system. Insert PRIMERGY Startup Disc Win64. 11 When a message prompts you to insert the OS CD/DVD, insert the CD/DVD and click [OK]. For Windows Server 2008 1. Insert the OS CD/DVD (Installation disc). Copying files starts. After files are copied, a message prompts you to eject the CD/DVD and floppy disk.  For Windows Server 2008 (64-bit), a message appears and prompts you to insert the PRIMERGY Startup Disc again. Insert PRIMERGY Startup Disc. After files are copied, a message prompts you to eject the CD/DVD and floppy disk. 52 PRIMERGY BX620 S4 Server Blade User’s Guide For Windows Server 2003 / Windows Server 2003 x64 1. Insert the OS CD/DVD (Installation disc). The license agreement window appears. 2. Click [Accept]. After files are copied, a message prompts you to eject the CD/DVD and floppy disk. For Windows Server 2003 R2 / Windows Server 2003 R2 x64 1. Insert the OS CD/DVD (Installation disc) Disc 1. The license agreement window appears. 2. Click [Accept]. After files are copied, a message prompts you to insert the Disc 2. 3. Insert the OS CD/DVD (Installation disc) Disc 2. After files are copied, a message prompts you to eject the CD/DVD and floppy disk. 12 Eject the CD/DVD and floppy disk and click [OK]. The system is restarted. The system continues the installation operation after restart. Setup of OS GUI and installation of LAN utility, Service Pack, and Active Directory are performed automatically. 13 When a confirmation message to restart appears, click [Restart]. The system restarts and installs high reliability tools.  Thus the Command Prompt windows may appear and disappear during installation of ServerView, the installation process is properly proceeding.  When using Microsoft media, the screen to input a product key may be displayed during OS installation. When the input screen is displayed, input the product key again. 14 When a message notifies completion of installation, restart the system. For Windows Server 2008 The system automatically restarts when a message notifies completion of installation. After restarting, enter the set password to log in. For Windows Server 2003 Press the [Enter] key when a message notifies completion of installation. Click [Start] – [Shutdown] to restart the system. After restarting, enter the specified password to login. 15 Perform settings for the RAID management tool (ServerView RAID). For details, refer to the manuals in the Array Controller Document & Tool CD. For the manual of the SAS RAID Ctrl to be used, refer to "2.3.2 Notes on Configuring RAID" (pg.42). • Setting an array administrator account A Windows user account is required when using ServerView RAID. Create the group "raidadm", and create an account with any name for an array administrator in this group. • Setting the HDD check scheduler When using the SAS RAID Ctrl (MegaRAID SAS), change the settings for the HDD check scheduler according to the operation that is required. It is set to 12:00 everyday as default. 53 Chapter 3 OS Installation using ServerStart 16 Perform settings for ServerView. Refer to "2.4 Checking after Installation" in "ServerView User's Guide" to perform the necessary settings. The server setup and OS installation have been completed. Refer to "Chapter 5 Operations after OS Installation" (pg.99) and perform necessary procedures before starting server operations. 54 PRIMERGY BX620 S4 Server Blade User’s Guide 3.2 Expert Mode In the expert mode, start up Disk Manager, format the installation partition, and install the OS. Use this mode only when you want to perform installation while maintaining the existing partitions.  Windows Server 2008 cannot be installed in Expert mode. 3.2.1 Starting Up the Expert Mode Start up the expert mode. 1 Connect the USB CD/DVD drive and USB floppy disk drive to the Server Blade. Use the Display/USB Extension Cable to connect the USB CD/DVD drive and USB floppy disk drive. For more information on the connection procedure, refer to "Start Guide". 2 Turn on the server and insert PRIMERGY Startup Disc immediately. ServerStart starts up. The select-media window for the configuration file appears. 55 Chapter 3 OS Installation using ServerStart 3 Set the ServerStart floppy disk, and ensure that "Removable media" and "A:" are selected. Click [Continue]. The [Initialization of ServerStart core running] window appears and the ServerStart initialization process starts. Depending on hardware configuration, this process may take a few minutes. After completion, the license agreement window appears. 4 Click [Accept]. The [Welcome to ServerStart] window appears. 56 PRIMERGY BX620 S4 Server Blade User’s Guide 5 Select [Expert Installation] and click [Next]. The [Create a ServerStart Floppy Disk] window appears. 6 Click [Build a ServerStart Floppy Disk]. Creation of a ServerStart floppy disk starts. When the creation is completed, the "Floppy disk has been created." message appears. 7 Click [OK]. The [Please Select your Keyboard] window appears. 8 Select your keyboard language from the drop-down list and click [OK]. The subsequent start procedure may take several minutes. The [Welcome to ServerStart] window appears. 57 Chapter 3 OS Installation using ServerStart 9 Click [Click here to prepare and/or initiate an operating system installation]. The [Select the operating system to be installed] window appears. Click [Special Hints on Operating System Installation] and observe them carefully. Important information such as limitations on configuration of hard disk units is described. 10 Click [MS Windows Operating Systems]. The [Microsoft Windows Operating System Installation] window appears. 11 Click [Install MS Windows Server 2003 or MS]. The [Installation of MS Windows Server 2003] window appears. 12 Click [Install MS (OS) interactively (expertise required)]. The expert mode starts. Start up the configuration tools to set items. Exiting a tool returns to the display to the expert mode window.  Make sure to open the menu of each wizard and confirm the settings. 58 PRIMERGY BX620 S4 Server Blade User’s Guide 3.2.2 Disk Manager Start up Disk Manager and format the installation partition. 1 Click [Use Disk Manager to partition and format your disk drives]. Disk Manager starts up. 2 Format the OS installation partition. Select the OS installation partition and click the [Partition] menu – [Format]. The [Format Partition] window appears.  Be sure to set the active partition on drive C. 3 Set items and click [Format]. The partition is formatted. 4 When the formatting is completed, click the [File] menu – [Exit]. Disk Manager closes and the display returns to the expert mode window. 59 Chapter 3 OS Installation using ServerStart 3.2.3 OS Installation Wizard Set computer information, user information, and the network protocol. ServerStart can configure multiple network patterns. When configuring a domain controller, refer to "Using ServerStart to Configure the Network".  The setup windows vary depending on the OS to be installed. For example, operation on Server 2003 R2 is given below. Server 2003 R2 is corresponding to your OS to be installed. 1 Click [Installation Wizard for MS Windows Server 2003]. A message prompts you to specify the configuration file. 2 Click [No]. The [Windows Installation] window appears. 3 Enter the password in [Password for Administrator account] and [Please repeat Password] and click [Next].  If the passwords of [Password for Administrator account] and [Please repeat Password] are not identical, an error message occurs. Enter the password correctly. 60 PRIMERGY BX620 S4 Server Blade User’s Guide The [Computer Identification] window appears. 4 Set items and click [next]. The [Installation Directory and Time Zone] window appears. 61 Chapter 3 OS Installation using ServerStart 5 Set items and click [next]. The [User Name] window appears. 6 Set items and click [next]. The [Display Settings] window appears. 7 Set items and click [next]. The [Network Protocol] window appears. 62 PRIMERGY BX620 S4 Server Blade User’s Guide 8 Set items and click [next]. The [Software Components] window appears.  If Windows Server 2003 R2 is selected at the Computer Identification, R2 components are always copied to the hard disk. To install the components, click [Properties] and check t box of the components to be installed. 63 Chapter 3 OS Installation using ServerStart 9 Set items and click [next]. The [Services] window appears.  Simple Network Management Protocol is always installed. Click [Properties] to change the settings. 10 Set items and click [leave wizard]. The display returns to the expert mode window. 64 PRIMERGY BX620 S4 Server Blade User’s Guide 3.2.4 Application Wizard Set configurations for installation of high reliability tools. Open those windows and confirm the settings carefully. 1 Click [Application Wizard: Select additional software components]. The application wizard appears. 2 From the list in [Installable applications], select application software to be installed and click [>>]. Set all applications to be installed on the [Selected applications] list.  Although the selection can be released in the expert mode, it may take a long time to restore the system when errors occur without the management tools. Be sure to install these tools. •DSNAP •Broadcom Advanced Control Suite •RAID Management Tool •ServerView (for Apache) •ServerView (for IIS)  Service Pack 1 or Service Pack 2 can be installed with ServerStart. 3 Click [leave wizard]. The application wizard closes. 65 Chapter 3 OS Installation using ServerStart 3.2.5 Starting OS Installation Install the OS to the server. Notes on the Installation  When the installation partition is not empty, a confirmation message appears. Unless otherwise considered as problem, click [OK] to continue the installation procedure.  If an incorrect setting (such as the CD key) is found during installation, an error window will appear. Enter the correct values in the window to continue the installation procedure. However, corrections made here are not reflected on the configuration file. 1 Click [Click here, to Start the Installation of (OS)]. A confirmation window asking whether you want to save the current settings appears. 2 Click [Yes]. The following window appears. 3 Enter the file name and click [Save As]. Installation starts automatically. 1. If a message prompts you to insert Array Controller Document & Tool CD, insert the CD-ROM and click [OK]. 2. If a message prompts you to insert the Service Pack CD-ROM, insert the CD-ROM and click [OK]. 3. For Server 2003 x64, a message prompts you to insert PRIMERGY Startup Disc Win64 and restart the system. Insert PRIMERGY Startup Disc Win64. 66 PRIMERGY BX620 S4 Server Blade User’s Guide 4 When a message prompts you to insert the OS CD/DVD, insert the CD/DVD and click [OK]. For Windows Server 2003 / Windows Server 2003 x64 1. Insert the OS CD/DVD (Installation disc). The license agreement window appears. 2. Click [I agree]. After files are copied, a message prompts you to eject the CD/DVD and floppy disk. For Windows Server 2003 R2 / Windows Server 2003 R2 x64 1. Insert the OS CD/DVD (Installation disc) Disc 1. The license agreement window appears. 2. Click [I agree]. After files are copied, a message prompts you to insert the Disc 2. 3. Insert the Disc 2 of OS CD/DVD (Installation disc). After files are copied, a message prompts you to eject the CD/DVD and floppy disk. 5 Eject the CD/DVD and floppy disk and click [OK]. The system is restarted. The system continues the installation operation after restart. Setup of OS GUI and installation of LAN utility, Service Pack, and Active Directory are performed automatically. 6 When a confirmation message to restart appears, click [Restart]. The system restarts and installs high reliability tools.  Thus the Command Prompt windows may appear and disappear during installation of ServerView, the installation process is properly proceeding. 7 Press the [Enter] key when a message notifies completion of installation. 8 Restart the system. Click [Start] – [Shutdown] to restart the system. After restarting, enter the specified password to login. 9 Perform settings for the RAID management tool (ServerView RAID). For details, refer to the manual in the Array Controller Document & Tool CD. For the manual of the SAS RAID Ctrl to be used, refer to "2.3.2 Notes on Configuring RAID" (pg.42). • Setting an array administrator account A Windows user account is required when using ServerView RAID. Create the group "raidadm", and create an account with any name for an array administrator in this group. • Setting the HDD check scheduler When using the SAS RAID Ctrl (MegaRAID SAS), change the settings for the HDD check scheduler according to the operation that is required. It is set to 12:00 everyday as default. 10 Perform settings for ServerView. Refer to "2.4 Checking after Installation" in "ServerView User's Guide" to perform the necessary settings. 67 Chapter 3 OS Installation using ServerStart The server setup and OS installation have been completed. Refer to "Chapter 5 Operations after OS Installation" (pg.99) and perform necessary procedures before starting server operations. 68 Chapter 4 Manual OS Installation This chapter explains how to install the OS without using ServerStart. 4.1 4.2 4.3 4.4 4.5 Creating Driver Disks . . . . . . . . . . . . . . . . . . . . . . . . . . . Starting Manual Installation . . . . . . . . . . . . . . . . . . . . . . . Installing the LAN Driver . . . . . . . . . . . . . . . . . . . . . . . . . Installing the Fibre Channel Driver . . . . . . . . . . . . . . . . . . Installing SAS RAID Ctrl Driver . . . . . . . . . . . . . . . . . . . . 70 76 89 94 97 69 Chapter 4 Manual OS Installation 4.1 Creating Driver Disks When installing the OS manually, it is necessary to create driver installation disks beforehand. Also, driver disks must be created when you add an expansion card during server operation. 4.1.1 Required Driver Disks You need floppy disks for driver disks. A floppy disk is necessary for each driver. Required driver disks vary with the OS.  Standard driver provided with the OS is installed automatically at the OS installation.  You need a PRIMERGY Startup Disc to install the driver provided with the PRIMERGY Startup Disc. Prepare for it in advance.  For Windows Server 2008 (32-bit/64-bit) table: Drivers Required for Installing Windows Server 2008 (32-bit/64-bit) Expansion board / onboard controller 70 Driver Chipset OS standard Onboard VGA Driver provided with the PRIMERGY Startup Disc Onboard LAN controller Driver provided with the PRIMERGY Startup Disc Onboard array controller OS standard Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L) 1 Gbit/s Ethernet I/O Module (PG-LND201) Driver provided with the PRIMERGY Startup Disc 2Gbit/s FC I/O Module Driver provided with the PRIMERGY Startup Disc 4Gbit/s FC I/O Module Driver provided with the PRIMERGY Startup Disc SCSI Ctrl U160 lp (PG-1301L) OS standard SAS RAID Ctrl (PG-248EL) OS standard PRIMERGY BX620 S4 Server Blade User’s Guide  For Windows Server 2003 x64 table: Drivers Required for Installing Windows Server 2003 x64 Expansion board / onboard controller Driver Chipset Driver provided with the PRIMERGY Startup Disc Onboard VGA Driver provided with the PRIMERGY Startup Disc Onboard LAN controller Driver provided with the PRIMERGY Startup Disc Onboard array controller PRIMERGY BX620 S4 Onboard SAS/RAID Driver for Windows Server 2003 x64 V1.25.05.00 *1 Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L) 1 Gbit/s Ethernet I/O Module (PG-LND201) Driver provided with the PRIMERGY Startup Disc 2Gbit/s FC I/O Module Driver provided with the PRIMERGY Startup Disc 4Gbit/s FC I/O Module Driver provided with the PRIMERGY Startup Disc SCSI Ctrl U160 lp (PG-1301L) OS standard SAS RAID Ctrl (PG-248EL) Driver provided with the PRIMERGY Startup Disc *1: Create using the ServerStart FloppyBuilder function.  For Windows Server 2003 table: Drivers Required for Installing Windows Server 2003 Expansion board / onboard controller Chipset Driver Driver provided with the PRIMERGY Startup Disc Onboard VGA Driver provided with the PRIMERGY Startup Disc Onboard LAN controller Driver provided with the PRIMERGY Startup Disc Onboard array controller PRIMERGY BX620 S4 Onboard SAS/RAID Driver for Windows Server 2003 V1.25.05.00 *1 Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L) 1 Gbit/s Ethernet I/O Module (PG-LND201) Driver provided with the PRIMERGY Startup Disc 2Gbit/s FC I/O Module Driver provided with the PRIMERGY Startup Disc 4Gbit/s FC I/O Module Driver provided with the PRIMERGY Startup Disc SCSI Ctrl U160 lp (PG-1301L) OS standard SAS RAID Ctrl (PG-248EL) Driver provided with the PRIMERGY Startup Disc *1: Create using the ServerStart FloppyBuilder function. 71 Chapter 4 Manual OS Installation 4.1.2 How to Create Driver Disks [FloppyBuilder Function] Driver disks are created from the PRIMERGY Startup Disc using the ServerStart FloppyBuilder function. The FloppyBuilder function is available in the following environments. • Starting up the ServerStart system on a client computer (Recommended) • Starting up the system from the PRIMERGY Startup Disc on the server  When creating driver disks on a client computer, it is necessary to install ServerStart on the client computer beforehand, referring to "5.4.1 Installing ServerStart" (pg.113). If a different version of ServerStart has been installed, uninstall it and install the proper version. For details on how to uninstall ServerStart, refer to " Uninstalling ServerStart" (pg.115).  Starting ServerStart If ServerStart has already been started, it is not necessary to restart it. If it has not, start it up according to the following procedures:  For creation on a client computer 1 Set the PRIMERGY Startup Disc to the client computer. Once "PRIMERGY Startup Disc" window appears, exit the window. 2 Click [Start] − [All Programs] − [Fujitsu Siemens ServerStart] – [ServerStart (Start from DVD)]. ServerStart starts up and the [Welcome to ServerStart] window appears. 72 PRIMERGY BX620 S4 Server Blade User’s Guide  For creation on the server 1 Connect the USB CD/DVD drive and USB floppy disk drive to the Server Blade. Use the Display/USB Extension Cable to connect the USB CD/DVD drive and USB floppy disk drive. For more information on the connection procedure, refer to "Start Guide". 2 Turn on the power of the Server Blade and set PRIMERGY Startup Disc. ServerStart starts up and select media window for the configuration file appears. 3 Insert the ServerStart floppy disk. Make sure that "on local drive (floppy/USB stick)" and "A:" are selected and click [Continue]. The [Initialization of ServerStart core running] window appears and the initialization operation launches. In some cases, initialization operation may take a few minutes, depending on hardware configuration. After completion, the license agreement window appears. 4 Click [Accept]. The [Welcome to ServerStart] window appears. 73 Chapter 4 Manual OS Installation 5 Click [Expert Installation] and click [OK]. The [Welcome to ServerStart] window appears. 6 Eject the ServerStart floppy disk.  Creating driver disks Start up ServerStart and confirm that the [Welcome to ServerStart] window is displayed. 1 Click [FloppyBuilder]. The [ServerStart FloppyBuilder] window appears. 2 Select [Drivers Diskettes (for OS)]. The [FloppyBuilder Driver Disk] window appears. 3 Click the type of the driver you want to create. 74 PRIMERGY BX620 S4 Server Blade User’s Guide 4 Click the driver disk you want to create. Follow the message and insert a floppy disk. 5 Perform the subsequent operations according to the messages on the window. The floppy disk will be formatted automatically and file copying will start. The driver disk is automatically created. When a message appears indicating that creating the disk is completed, click [OK] and eject the floppy disk. 75 Chapter 4 Manual OS Installation 4.2 Starting Manual Installation This section explains the procedures for installing the OS manually.  Using the USB CD/DVD drive / USB floppy disk drive It is strongly recommended that only products listed on the following website are connected to the server. Fujitsu PRIMERGY website (http://primergy.fujitsu.com) 4.2.1 Installing Windows Server 2008 (Full)  Installation procedure 1 Create driver disks. Prepare the necessary drivers before installing Windows Server 2008. Some drivers are created from the PRIMERGY Startup Disc. For details about how to create driver disks, refer to "4.1 Creating Driver Disks" (pg.70). 2 Connect the USB CD/DVD drive and USB floppy disk drive to the Server Blade. Use the Display/USB Extension Cable to connect the USB CD/DVD drive and USB floppy disk drive. For more information on the connection procedure, refer to "Start Guide". 3 Turned on the Server Blade and configure RAID. Turn on the Server Blade to display the following message and press the [Ctrl] + [C] key to start up the BIOS Utility. If RAID is not required to be configured, proceed to step 4. Press Ctrl C to start LSI Logic Configuration Utility The array system is configured by using BIOS Utility. For more details, refer to the manual in the Array Controller Document & Tool CD. Turn off the Server Blade after configuring the array system. 4 Turn the Server Blade on again, and insert the Windows Server 2008 DVDROM into the CD/DVD drive. There are two DVD-ROMs, for 32bit and for 64bit. Check them before inserting the DVD-ROM. When the active area is specified on the hard disk, the following message appears. Press any key to boot from CD or DVD... Pressing any key while this message is displayed boots the system from the DVD-ROM. 76 PRIMERGY BX620 S4 Server Blade User’s Guide 5 Setup window for Windows Server 2008 installation appears. Set each item according to the window. 6 Click [Next]. Continue installation procedures according to the setup window. The OS selection window appears. 77 Chapter 4 Manual OS Installation 7 Select the OS to be installed. Select "Windows Server 2008 Standard (full installation)". The license agreement window appears. 8 After reading through its contents, check [Accept] and click [Next]. OS installation is automatically performed by the setup program (reboot will occur a few times). 9 Proceed to the installation procedure following the setup program instructions. If a message stating that the driver has not passed the Windows logo test to verify convertibility with Windows is displayed while installing, select [Yes] to proceed with the installation. 10 Install the display driver. 1. Click [Start] – [Administrative Tools] – [Computer Management]. 2. Click [Device Manager] from the displayed list. 3. Double-click [Standard VGA Graphics Adapter] under [Display Adapters] to display the property window. 4. Click the [Driver] tab and click [Updating Driver]. The [Update Driver Software] window appear. 5. Click [Browse my computer for driver software]. 6. Insert PRIMERGY Startup Disc, and click [Browse] to select the following folder. • Windows Server 2008 Standard (32-bit) [CD/DVD drive]: \VGA_8.24.50.3\Driver\XP_INF • Windows Server 2008 Standard (64-bit) [CD/DVD drive]: \VGA_8.24.50.3\Driver\XP6A_INF When driver installation has completed, the following message is displayed. Driver software installation for this device has completed: ATI ES1000 7. Reboot the server.  VGA chip installation cannot be performed by using the installer. 11 Install the LAN driver. Install the LAN driver using the PRIMERGY Startup Disc. For details, refer to "4.3 Installing the LAN Driver" (pg.89). 12 Install the Fibre Channel Driver. When the Fibre Channel Expansion Board has been installed, install the Fibre Channel Driver using the PRIMERGY Startup Disc. For details, refer to "4.4 Installing the Fibre Channel Driver" (pg.94). 13 Install high reliability tools. To ensure stable server operation, refer to "Chapter 6 High Reliability Tools" (pg.163) and install high reliability tools. 78 PRIMERGY BX620 S4 Server Blade User’s Guide 14 Perform settings for the RAID management tool (ServerView RAID). For details, refer to the manual in the Array Controller Document & Tool CD. For the manual of the SAS RAID Ctrl to be used, refer to "2.3.2 Notes on Configuring RAID" (pg.42). • Setting an array administrator account A Windows user account is required when using ServerView RAID. Create the group "raidadm", and create an account with any name for an array administrator in this group. • Setting the HDD check scheduler When using the SAS RAID Ctrl (MegaRAID SAS), change the settings for the HDD check scheduler according to the operation that is required. It is set to 12:00 everyday as default. The installation of Windows Server 2008 is completed.  Before starting operation After OS installation, refer to "Chapter 5 Operations after OS Installation" (pg.99) and perform necessary operations. 4.2.2 Installing Windows Server 2008 (Server Core)  Installation procedure 1 Create driver disks. Prepare the necessary drivers before installing Windows Server 2008 Server Core. Some drivers are created from the PRIMERGY Startup Disc. For details about how to create driver disks, refer to "4.1 Creating Driver Disks" (pg.70). 2 Connect the USB CD/DVD drive and USB floppy disk drive to the Server Blade. Use the Display/USB Extension Cable to connect the USB CD/DVD drive and USB floppy disk drive. For more information on the connection procedure, refer to "Start Guide". 3 Turned on the Server Blade and configure RAID. Turn on the Server Blade to display the following message and press the [Ctrl] + [C] key to start up the BIOS Utility. If RAID is not required to be configured, proceed to step 4. Press Ctrl C to start LSI Logic Configuration Utility The array system is configured by using BIOS Utility. For more details, refer to the manual in the Array Controller Document & Tool CD. Turn off the Server Blade after configuring the array system. 79 Chapter 4 Manual OS Installation 4 Turn the Server Blade on again, and insert the Windows Server 2008 DVDROM into the CD/DVD drive. There are two DVD-ROMs, for 32bit and for 64bit. Check them before inserting the DVD-ROM. When the active area is specified on the hard disk, the following message appears. Press any key to boot from CD or DVD... Pressing any key while this message is displayed boots the system from the DVD-ROM. 5 The setup window for Windows Server 2008 installation appears. Set each item according to the window. 80 PRIMERGY BX620 S4 Server Blade User’s Guide 6 Click [Next]. Continue the installation procedure according to the setup window. The OS selection window appears. 7 Select the OS to be installed. Select "Windows Server 2008 Standard (Server Core installation)". The license agreement window appears. 8 After reading through its contents, check [Accept] and click [Next]. OS installation is automatically performed by the setup program (reboot will occur a few times). 9 Set a password for the Administrator. Click "Other Users" when it is displayed. The user ID and password entry window appears. Enter "Administrator" as the ID, leave password empty and click [→]. The window where the password can be changed appears. 10 Install SNMP service. 1. Execute the following command (case-sensitive). >start /w ocsetup SNMP-SC 2. Execute the following command to check that SNMP is installed properly. >oclist | findstr SNMP When the following message is displayed, it is installed properly. Installed: SNMP-SC 81 Chapter 4 Manual OS Installation 11 Install the LAN driver. Install the LAN driver using the PRIMERGY Startup Disc. For details, refer to "4.3 Installing the LAN Driver" (pg.89). 12 Install the Fibre Channel Driver. Install the Fibre Channel Driver using the PRIMERGY Startup Disc. For details, refer to "4.4 Installing the Fibre Channel Driver" (pg.94). 13 Install the ServerView Agent. For the procedure for installing, refer to "ServerView User's Guide (For Windows Agent)".  For Windows Server 2008 Server Core, ServerView Console and ServerView RemoteControlService cannot be installed. Another system is required for installation. 14 Perform settings for the RAID management tool (ServerView RAID). For details, refer to the manual in the Array Controller Document & Tool CD. For the manual of the SAS RAID Ctrl to be used, refer to "2.3.2 Notes on Configuring RAID" (pg.42). • Setting an array administrator account A Windows user account is required when using ServerView RAID. Create the group "raidadm", and create an account with any name for an array administrator in this group. • Setting the HDD check scheduler When using the SAS RAID Ctrl (MegaRAID SAS), change the settings for the HDD check scheduler according to the operation that is required. It is set to 12:00 everyday as default. The installation of Windows Server 2008 Server Core is completed.  Before starting operation After OS installation, refer to "Chapter 5 Operations after OS Installation" (pg.99) and perform necessary operations. 82 PRIMERGY BX620 S4 Server Blade User’s Guide 4.2.3 Installing Windows Server 2003 x64  Installation procedure 1 Create driver disks. Prepare the necessary drivers before installing Windows Server 2003 x64. Some drivers are created from the PRIMERGY Startup Disc, or download file from the Fujitsu PRIMERGY website (http://primergy.fujitsu.com). For details about how to create driver disks, refer to "4.1 Creating Driver Disks" (pg.70). 2 Connect the USB CD/DVD drive and USB floppy disk drive to the Server Blade. Use the Display/USB Extension Cable to connect the USB CD/DVD drive and USB floppy disk drive. For more information on the connection procedure, refer to "Start Guide". 3 Turned on the Server Blade and configure RAID. If RAID is not required to be configured, proceed to step 4. Turn on the server to display the following message and press the [Ctrl] + [C] key to start up the BIOS Utility. Press Ctrl C to start LSI Logic Configuration Utility The array system is configured by using BIOS Utility. For more details, refer to the manual in the Array Controller Document & Tool CD. Turn off the Server Blade after configuring the array system. 4 Insert the Windows Server 2003 x64 CD/DVD (installation disc). Turn on the Server Blade after checking there are no floppy disks in the floppy disk drive, and insert the Windows Server 2003 x64 CD/DVD immediately into the CD/DVD drive. When the active area is specified on the hard disk, the following message appears. Press any key to boot from CD... Pressing any key while this message is displayed boots the system from the CD/DVD. 5 After the [Windows Server 2003 x64 Setup] window appears, press the [F6] key. Immediately, the following message appears at the bottom of the window. Press the [F6] key. Press F6 if you need to install a third party SCSI or RAID driver...  This message will be displayed for a short time after the setup window (blue screen) appears. Press the [F6] key immediately after the window turns blue. 83 Chapter 4 Manual OS Installation 6 Install the Drivers for onboard array controller manually. 1. When the following message appears, press the [S] key. To specify additional SCSI adapters, CD-ROM drives, or special disk controllers for use with Windows, including those for which you have a device support disk from a mass storage device manufacturer, press S. 2. When the "Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A:" message appears, insert the driver disk created from the driver’s CD and press the [Enter] key. The following message appears. You have chosen to configure a SCSI Adapter for use with Windows, using a device support disk provided by an adapter manufacturer. Select the SCSI Adapter you want from the following list, or press ESC to return to the previous screen. 3. Select following item and press the [Enter] key. LSI Logic Fusion-MPT SAS Driver(Server 2003 x64) 4. When the following message appears, press the [S] key. The driver you provided seems to be newer than the Windows default driver. 5. Follow the instructions in the window to perform installation The message which prompts you to set the floppy disk appears during the installation, insert the driver disk and push the [Enter] key. 7 Follow the instructions from the setup program to continue the installation procedures. If a message indicating that the driver has failed in the Windows logo test for validating the compatibility with Windows appears, select [Yes] to continue the installation procedure. 8 Install the ChipSet driver. 1. Insert the PRIMERGY Startup Disc into the drive of the server. When the ServerStart window appears, exit ServerStart. 2. Execute the following command on the PRIMERGY Startup Disc. [CD/DVD drive]: \DRIVERS\ChipSet\Intel\5000P\infinst_autol.exe The installation wizard starts up. 3. Click [Next]. Follow the instructions in the window to perform installation. 4. When the "InstallShield® wizard has completed" message appears, eject the PRIMERGY Startup Disc from the CD/DVD drive and click [Finish] to restart the system. 84 PRIMERGY BX620 S4 Server Blade User’s Guide 9 Install the display driver. 1. Insert the PRIMERGY Startup Disc into the drive of the server. When the ServerStart window appears, exit ServerStart. 2. Execute the following command on the PRIMERGY Startup Disc. [CD/DVD drive]: \DRIVERS\VIDEO\ES1000\Setup.exe The installation wizard starts up. 3. Click [Next]. Follow the instructions in the window to perform installation. 4. When the installation is completed, eject the PRIMERGY Startup Disc from the CD/ DVD drive and click [Finish] to restart the system. 10 Install the LAN driver. Install the LAN driver using the PRIMERGY Startup Disc. For details, refer to "4.3 Installing the LAN Driver" (pg.89). 11 Install the Fibre Channel Driver. When the Fibre Channel Expansion Board has been installed, install the Fibre Channel Driver using the PRIMERGY Startup Disc. For details, refer to "4.4 Installing the Fibre Channel Driver" (pg.94). 12 Install high reliability tools. To ensure stable server operation, refer to "Chapter 6 High Reliability Tools" (pg.163) and install high reliability tools. 13 Perform settings for the RAID management tool (ServerView RAID). For details, refer to the manual in the Array Controller Document & Tool CD. For the manual of the SAS RAID Ctrl to be used, refer to "2.3.2 Notes on Configuring RAID" (pg.42). • Setting an array administrator account A Windows user account is required when using ServerView RAID. Create the group "raidadm", and create an account with any name for an array administrator in this group. • Setting the HDD check scheduler When using the SAS RAID Ctrl (MegaRAID SAS), change the settings for the HDD check scheduler according to the operation that is required. It is set to 12:00 everyday as default. The installation of Windows Server 2003 x64 is completed.  Before starting operation After OS installation, refer to "Chapter 5 Operations after OS Installation" (pg.99) and perform necessary operations. 85 Chapter 4 Manual OS Installation 4.2.4 Installing Windows Server 2003 1 Create driver disks. Prepare necessary drivers before installing Windows Server 2003. Some drivers are created from the PRIMERGY Startup Disc. For how to create driver disks, refer to "4.1 Creating Driver Disks" (pg.70). 2 Connect the USB CD/DVD drive and USB floppy disk drive to the Server Blade. Use the Display/USB Extension Cable to connect the USB CD/DVD drive and USB floppy disk drive. For more information on the connection procedure, refer to "Start Guide". 3 Turned on the Server Blade and configure RAID. If RAID is not required to be configured, proceed to step 4. Turn on the server to display the following message and press the [Ctrl] + [C] key to start up the BIOS Utility. Press Ctrl C to start LSI Logic Configuration Utility The array system is configured by using BIOS Utility. For more details, refer to the manual in the Array Controller Document & Tool CD. Turn off the Server Blade after configuring the array system. 4 Insert the Windows Server 2003 CD/DVD. Turn on the Server Blade and insert the Windows Server 2003 CD/DVD immediately into the CD/DVD drive. Check there are no floppy disks in the floppy disk drive. When the active area is specified on the hard disk, the following message appears. Press any key to boot from CD... Pressing any key while this message is displayed boots the system from the CD/DVD. 5 The [Windows Server 2003 Setup] window appears. Immediately, the following message appears at the bottom of the window. Press the [F6] key. Press F6 if you need to install a third party SCSI or RAID driver...  This message will be displayed for a short time after the setup window (blue screen) appears. Press the [F6] key immediately after the window turns blue. 86 PRIMERGY BX620 S4 Server Blade User’s Guide 6 Install the Drivers for onboard array controller manually. 1. When the following message appears, press the [S] key. To specify additional SCSI adapters, CD-ROM drives, or special disk controllers for use with Windows, including those for which you have a device support disk from a mass storage device manufacturer, press S. 2. When the "Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A:" message appears, insert the driver disk created and press the [Enter] key. The following message appears. You have chosen to configure a SCSI Adapter for use with Windows, using a device support disk provided by an adapter manufacturer. Select the SCSI Adapter you want from the following list, or press ESC to return to the previous screen. 3. Select following item and press the [Enter] key. LSI Logic Fusion-MPT SAS Driver(Server 2003 32-bit) 4. When the following message appears, press the [S] key. The driver you provided seems to be newer than the Windows default driver. 5. Follow the instructions in the window to perform installation The message which prompts you to set the floppy disk appears during the installation, set the driver disk and push the [Enter] key. 7 Follow the instructions from the setup program to continue the installation procedures. If a message indicating that the driver has failed in the Windows logo test for validating the compatibility with Windows appears, select [Yes] to continue the installation procedure. 8 Apply Windows Server 2003 Service Pack. For details, refer to the description in the window. 9 Install the ChipSet driver. 1. Insert the PRIMERGY Startup Disc into the drive of the server. When the ServerStart window appears, exit ServerStart. 2. Execute the following command on the CD/DVD. [CD/DVD drive]: \DRIVERS\ChipSet\Intel\5000P\infinst_autol.exe The installation wizard starts up. 3. Click [Next]. Follow the instructions in the window to perform installation. 4. When the "InstallShield® wizard has completed" message appears, eject the PRIMERGY Startup Disc from the CD/DVD drive and click [Finish] to restart the system. 87 Chapter 4 Manual OS Installation 10 Install the display driver. 1. Insert the PRIMERGY Startup Disc into the drive of the server. When the ServerStart window appears, exit ServerStart. 2. Execute the following command on the PRIMERGY Startup Disc. [CD/DVD drive]: \DRIVERS\VIDEO\ES1000\Setup.exe The installation wizard starts up. 3. Click [Next]. Follow instructions in the window to perform installation. When the installation is completed, the completion window appears. 4. Eject the PRIMERGY Startup Disc from the CD/DVD drive, click [Finish], and restart the system. 11 Install the LAN driver. Use the PRIMERGY Startup Disc to install the LAN driver. For more details, refer to "4.3 Installing the LAN Driver" (pg.89). 12 Install the Fibre Channel Driver. When the Fibre Channel Expansion Board has been installed, install the Fibre Channel Driver using the PRIMERGY Startup Disc. For details, refer to "4.4 Installing the Fibre Channel Driver" (pg.94). 13 Install high reliability tools. To ensure stable server operation, refer to "Chapter 6 High Reliability Tools" (pg.163) and install high reliability tools. 14 Perform settings for the RAID management tool (ServerView RAID). For details, refer to the manual in the Array Controller Document & Tool CD. For the manual of the SAS RAID Ctrl to be used, refer to "2.3.2 Notes on Configuring RAID" (pg.42). • Setting an array administrator account A Windows user account is required when using ServerView RAID. Create the group "raidadm", and create an account with any name for an array administrator in this group. • Setting the HDD check scheduler When using the SAS RAID Ctrl (MegaRAID SAS), change the settings for the HDD check scheduler according to the operation that is required. It is set to 12:00 everyday as default. The installation of Windows Server 2003 has completed.  Before starting operation After OS installation, refer to "Chapter 5 Operations after OS Installation" (pg.99) and perform necessary operations. 4.2.5 Installing Linux For the use of Linux, refer to the Fujitsu PRIMERGY website (http://primergy.fujitsu.com). 88 PRIMERGY BX620 S4 Server Blade User’s Guide 4.3 Installing the LAN Driver This section explains the procedure for installing the driver.  For the latest drivers, refer to the Fujitsu PRIMERGY website (http://primergy.fujitsu.com). 4.3.1 Installing the LAN Driver Perform the following procedures to install the LAN driver. The procedures are the same for the full installation and the Server Core installation.  For Windows Server 2008 (32-bit)  For Onboard LAN 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Broadcom\Onboard\w2k8\setup.exe 3 Click [Next]. 4 Select [I accept the license agreement] and click [Next]. 5 Click [Install]. Driver installation starts. 6 Click [Finish]. 7 Eject the PRIMERGY Startup Disc and restart the Server Blade.  For Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L) 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Intel\APPS\PROSETDX\Vista32\DxSetup.exe The message "Welcome to InstallShield Wizard for Intel® Network Connection" is displayed. Proceed with the installation by following the instructions displayed in the window. Also, only check the following for program functions to be installed on the [Setup Options] window. For Server Core system, only drivers can be installed. • Driver 89 Chapter 4 Manual OS Installation • Intel® PROSet for Windows device manager • Advanced Network Service  For 1Gbit/s Ethernet I/O Module (PG-LND201) 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Broadcom\Ext\w2k8\setup.exe 3 Click [Next]. 4 Select [Modify], and click [Next]. 5 Click [Next]. 6 Click [Install]. Driver installation starts. 7 Click [Finish]. 8 Eject the PRIMERGY Startup Disc and restart the Server Blade.  For Windows Server 2008 (64-bit)  For Onboard LAN 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Broadcom\Onboard\w2k8x64\setup.exe 3 Click [Next]. 4 Select [I accept the license agreement] and click [Next]. 5 Click [Install]. Driver installation starts. 6 Click [Finish]. 7 Eject the PRIMERGY Startup Disc and restart the Server Blade. 90 PRIMERGY BX620 S4 Server Blade User’s Guide  For Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L) 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Intel\APPS\PROSETDX\Vistax64\DxSetup.exe The message "Welcome to InstallShield Wizard for Intel® Network Connection" is displayed. Proceed with the installation by following the instructions displayed in the window. Also, only check the following for program functions to be installed on the [Setup Options] window. For Server Core system, only drivers can be installed. • Driver • Intel® PROSet for Windows device manager • Advanced Network Service  For 1Gbit/s Ethernet I/O Module (PG-LND201) 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Broadcom\Ext\w2k8x64\setup.exe 3 Click [Next]. 4 Select [Modify], and click [Next]. 5 Click [Next]. 6 Click [Install]. Driver installation starts. 7 Click [Finish]. 8 Eject the PRIMERGY Startup Disc and restart the Server Blade.  For Windows Server 2003 x64  For Onboard LAN 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Broadcom\Onboard\DrvInst\x64\setup.exe 3 Click [Next]. Driver installation starts. 4 Click [Finish]. 91 Chapter 4 Manual OS Installation 5 Eject the PRIMERGY Startup Disc and restart the Server Blade.  For Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L) 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Intel\APPS\PROSETDX\Winx64\DxSetup.exe The message "Welcome to InstallShield Wizard" is displayed. Proceed with the installation by following the instructions displayed in the window. Also, only select [Drivers, Intel® PROSet, and Advanced Network Services] for program functions to be installed.  For 1Gbit/s Ethernet I/O Module (PG-LND201) 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Broadcom\Ext\W2K3x64\DrvInst\setup.exe 3 Click [Next]. Driver installation starts. 4 Click [Finish]. 5 Eject the PRIMERGY Startup Disc and restart the Server Blade.  For Windows Server 2003  For Onboard LAN 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Broadcom\Onboard\DrvInst\IA32\setup.exe 3 Click [Next]. Driver installation starts. 4 Click [Finish]. 5 Eject the PRIMERGY Startup Disc and restart the Server Blade. 92 PRIMERGY BX620 S4 Server Blade User’s Guide  For Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L) 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Intel\APPS\PROSETDX\Win32\DxSetup.exe The message "Welcome to InstallShield Wizard" is displayed. Proceed with the installation by following the instructions displayed in the window. Also, only select [Drivers, Intel® PROSet, and Advanced Network Services] for program functions to be installed.  For 1Gbit/s Ethernet I/O Module (PG-LND201) 1 Insert the PRIMERGY Startup Disc. 2 Execute the following file. \DRIVERS\LAN\Broadcom\Ext\W2K3\DrvInst\setup.exe 3 Click [Next]. Driver installation starts. 4 Click [Finish]. 5 Eject the PRIMERGY Startup Disc and restart the Server Blade. 93 Chapter 4 Manual OS Installation 4.4 Installing the Fibre Channel Driver This section explains how to install a fibre channel driver when the 2Gbit/s FC I/O Module (PG-FCD102) is extended. When 4Gbit/s FC I/O Module (PG-FCD201) is extended, refer to the option manual.  The latest drivers, refer to the Fujitsu PRIMERGY website (http://primergy.fujitsu.com). 4.4.1 For Windows Server 2008  For Windows Server 2008 (Full installation) 1 Click [Start] – [All Programs] – [Administrative Tools] – [Computer Management]. 2 Click [Device Manager]. Two fiber channel adapters of the 2Gbit/s FC I/O Module are displayed with the name below. • [QLogic Fibre Channel Adapter] under [Storage controllers] Double-click the fibre channel controller and perform the following Steps 3 to 12 on all fibre channel ports. 3 Double-click the icon or name of the fibre channel controller. The properties window appears. 4 Insert the PRIMERGY Startup Disc into the server. 5 Click the [Driver] tab and click [Update Driver]. The [Update Driver Software] window appears. 6 Select [Browse my computer for driver software]. 7 Select [Let me pick from a list of device drivers on my computer]. 8 Click [Have Disk]. 94 PRIMERGY BX620 S4 Server Blade User’s Guide 9 Enter the following folder name in [Copy manufacturer's files from] and click [OK]. • Windows Server 2008 (32-bit) [CD/DVD drive]: \DRIVERS\FCD\Qlogic\W2K8 • Windows Server 2008 (64-bit) [CD/DVD drive]: \DRIVERS\FCD\Qlogic\W2K8x64 10 Click [Next]. Driver installation starts. 11 Click [Close]. Detected drivers are displayed. 12 Click [Close].  For Windows Server 2008 (Server Core installation) 1 Insert the PRIMERGY Startup Disc into the server. 2 Move to the directory where the driver is stored using command prompt, and execute the following command. >pnputil -i -a ql2x00.inf 3 The following message is displayed. differs depending on the installation order. Processing inf : ql2x00.inf Successfully installed the driver on a device on the system. Driver package added successfully. Published name : oem.inf 95 Chapter 4 Manual OS Installation 4.4.2 For Windows Server 2003 1 Click [Start] – [Programs] – [Administrative Tools] – [Computer Management]. 2 Click [Device Manager]. Two ports of the fibre channel, which is installed in the 2Gbit/s FC I/O Module, are displayed with the names below. • [Fibre Channel Controller] under [Other Devices] • [QLogic Fibre Channel Adapter] under [SCSI and RAID controller] Double-click these fibre channel controllers and perform the following Steps 3 to 12 on all fibre channel ports. 3 Double-click the icon or name of the fibre channel controller. The properties window appears. 4 Insert the PRIMERGY Startup Disc into the server. 5 Click the [Driver] tab and click [Update Driver]. The [Welcome to the Hardware Update Wizard] window appears. 6 Select [Install from the list or specified location] and click [Next]. 7 Select [Not searching, and select installation driver], and click [Next]. 8 Click [Have Disk]. 9 Enter the following folder name in [Copy files from manufacture] and click [OK]. • Windows Server 2003 x64 [CD/DVD drive]: \DRIVERS\FCD\Qlogic\W2K3x64 • Windows Server 2003 [CD/DVD drive]: \DRIVERS\FCD\Qlogic\W2K3 10 Click [Next]. Driver installation starts. 11 Click [Finish]. Detected drivers are displayed. 12 Click [Exit]. 96 PRIMERGY BX620 S4 Server Blade User’s Guide 4.5 Installing SAS RAID Ctrl Driver This section explains how to install a driver when adding SAS RAID Ctrl (PG-248EL). Use the PRIMERGY Array Controller Document & Tool disk to install (update) the SAS RAID Ctrl driver. For details, refer to the manual in the Array Controller Document & Tool CD. 97 Chapter 4 Manual OS Installation 98 Chapter 5 Operations after OS Installation This chapter explains the operations to be performed after OS installation. Be sure to perform these operations before operating the server. 5.1 5.2 5.3 5.4 5.5 5.6 5.7 Memory Dump/Paging File Setting . . . . . . . . . . . . . . . . . . Creating Backup Data for System Recovery . . . . . . . . . . . Storing the System Setting Information . . . . . . . . . . . . . . Creating Maintenance Tools . . . . . . . . . . . . . . . . . . . . . . Notes Before Operating the Server . . . . . . . . . . . . . . . . . LAN Driver Advanced Setup [BACS] . . . . . . . . . . . . . . . . LAN Driver Advanced Setup [Intel® PROSet] . . . . . . . . . . 100 107 110 113 117 123 151 99 Chapter 5 Operations after OS Installation 5.1 Memory Dump/Paging File Setting Before start operating this server, configure the setting for obtaining memory dump. The setting procedure varies between Windows Server 2003 and Windows 2000 Server.  Memory dump If memory dump is set, debugging information will be automatically saved when a STOP error (fatal system error) occurs in the system. Using the saved memory dump, error cause can be analyzed. If the amount of installed memory is large, pay special attention when setting the memory dump file. The settings for obtaining memory dump should be configured after installing the files to be used for operations (OS, applications, etc.). 5.1.1 How to Obtain Memory Dump Check the following settings before starting configuration to obtain memory dump.  Checking hard disk free space To obtain memory dump, sufficient hard disk capacity is required for creating paging files and memory dump files. The obtainable dump types and required hard disk capacity are as follows:  Complete memory (full) dump (recommended) When the system unexpectedly stops, contents of the whole system memory are recorded. The file is stored in the directory displayed in the [Dump file] box. • Paging file: Installed physical memory + 11MB (Recommended: Installed physical memory × 1.5) • Memory dump file: Same amount as installed physical memory  When collecting a complete memory dump on a computer where there is 2GB or more of memory installed, use the registry editor to set the registry as follows. HKEY_LOCAL_MACHINE¥SYSTEM¥CurrentControlSet¥Control¥CrashControlCrashDumpEnabled = 1 (complete memory dump) For details, refer to Microsoft information (http://support.microsoft.com/kb/274598/). 100 PRIMERGY BX620 S4 Server Blade User’s Guide  Kernel memory dump Information of only kernel memory space is recorded. The file is stored in the directory displayed in the [Dump file] box. Capacity required for kernel memory dump is as follows: • Paging file: Depending on installed physical memory amount For memory of 256 to 1,373MB - Installed physical memory × 1.5 For memory of 1,374MB or more - 32-bit system: 2GB + 16MB For 64-bit system - RAM size + 128MB • Memory dump file: Depending on the used amount of kernel-mode address space during STOP  Minimum memory dump Minimum amount of useful information for problem identification is recorded. If this option is specified, a new file is created each time the system unexpectedly stops. History of such files is stored in the directory displayed in [Small dump directory]. • Paging file: 2MB or more • Memory dump file: 64KB or 128KB  Memory dump file setting Set up the memory dump file according to the following procedures: 1 Log on to the server with administrator privileges. 2 Check free space of the drive where the memory dump file is to be stored. Check the required amount of free space according to " Checking hard disk free space" (pg.100). If the drive has no free space, refer to " Cannot collect the memory dump" (pg.240). 3 Display the [System Properties] window. For Windows Server 2008 1. Click [Start] – [Control Panel]. Control Panel appears. 2. Double-click the [System] icon. System Control Panel appears. 3. Select [Advanced system settings] from the tasks. The [System Properties] window appears. For Windows Server 2003 1. Click [Start] – [Control Panel] – [System]. The [System Properties] window appears. 101 Chapter 5 Operations after OS Installation 4 Click the [Advanced] tab and click [Settings] in [Startup and Recovery]. The [Startup and Recovery] window appears. 5 Perform the following setting procedures. 1. In the [Write debugging information] section, select the memory dump file type. • Complete memory dump (Recommended) The whole system memory information is recorded to the memory dump file. • Small memory dump (64KB) Minimum information is recorded to the memory dump file. Each time a fatal error occurs, a new file is created in the directory specified in [Small dump directory]. • Kernel memory dump Only kernel memory is recorded to the memory dump file. 2. In [Dump file] or [Small dump directory], specify the directory to save the memory dump file, with its full path. In case of kernel memory dump or complete memory dump, if [Overwrite any existing file] is checked, debugging information is overwritten to the specified file every time. 6 Click [OK] to close the [Startup and Recovery] window. 7 Click [OK] to close the [System Properties] window. 8 Restart the system. The setting is enabled after the system is restarted. 102 PRIMERGY BX620 S4 Server Blade User’s Guide  Paging file setting Set up the paging file according to the following procedures: 1 Log on to the server with administrator privileges. 2 Check free space of the drive where the system is installed. Check the required amount of free space according to " Checking hard disk free space" (pg.100). If the drive has no free space, refer to " Cannot collect the memory dump" (pg.240). 3 Display the [System Properties] window. For Windows Server 2008 1. Click [Start] – [Control Panel]. Control Panel appears. 2. Double-click the [System] icon. System Control Panel appears. 3. Select [Advanced system settings] from the tasks. The [System Properties] window appears. For Windows Server 2003 1. Click [Start] – [Control Panel] – [System]. The [System Properties] window appears. 4 Click the [Advanced] tab and click [Settings] in [Performance]. The [Performance Options] window appears. 103 Chapter 5 Operations after OS Installation 5 Click the [Advanced] tab. For Windows Server 2008 For Windows Server 2003 104 PRIMERGY BX620 S4 Server Blade User’s Guide 6 Click [Change] in the [Virtual memory] section. The [Virtual Memory] window appears. For Windows Server 2008  If [Automatically manage paging file size for all drivers] is checked, uncheck it. For Windows Server 2003 7 Specify the drive where the paging file is to be created. In [Drive], select the drive where the system is installed. The selected drive is displayed in [Drive] in [Paging file size for selected drive]. 105 Chapter 5 Operations after OS Installation 8 Select [Custom size] and enter a value in [Initial size]. The value depends on the type of the set dump file. Specify a value larger than the value shown in [Recommended] in [Total paging file size for all drives].  When a smaller value is specified for the paging file size, performance may be affected. For maximum system efficiency, be sure to set [Initial size] with a value larger than the [Recommended] size described in [Total paging file size for all drives]. The recommended size is total memory installed in the system x 1.5. However, if a program consuming a large amount of memory is regularly used, set a larger size as required. 9 Enter a value in [Maximum size]. Specify a value larger than the [Initial size]. 10 Click [Set]. The settings are saved, and the value specified is displayed in [Paging File Size] of [Drive]. 11 Click [OK] to close the [Virtual Memory] window. 12 Click [OK] to close the [Performance Options] window. 13 Click [OK] to close the [System Properties] window. 14 Restart the system. The setting is enabled after the system is restarted.  Rebooting after OS dump setting Rebooting may not be executed when the server fails even if rebooting has been set after obtaining dumping. Immediate provision may be required when the server fails. However, configure the settings of rebooting with the Watchdog, when continuous operation is required. For details and configuration procedures for the software, the Watchdog, refer to "3.4 Serious Error Handling (ASR)" in "ServerView User’s Guide". 106 PRIMERGY BX620 S4 Server Blade User’s Guide 5.2 Creating Backup Data for System Recovery After OS installation is complete, create backup data for system recovery, which enables the system to be recovered if en error occurred.  When store the backup data in a floppy disk or CD/DVD, use the Display/USB Extension Cable to connect the USB floppy disk drive or USB CD/DVD drive. For more information on the connection procedure, refer to "Start Guide".  After OS installation or changing the system configuration, make sure to perform this procedure to create backup data. 5.2.1 Windows Server 2008 When installing Windows Server 2008, backup whole server configuration to media such as a shared folder or DVD. Windows Server backup function  For Windows Server 2008, backup and restoration of the whole system can be performed using the [Windows Server Backup] function. After installation, perform a full backup for the whole system configuration only once. Incremental backup can be specified to be automatically performed to only store changed data. Set or operate it according to the operation configuration.  Windows Server backup does not support a tape device. When using a tape device, use software for tape backup.  If setting up Windows Server 2008 Server Core, backup via the MMC console and Windows PowerShell are not supported. Only command line (Wbadmin command) backup is supported.  Installing a backup component In Windows Server 2008 default settings, backup components are not installed. Install it in advance. 1 Click [Start] – [Administrative Tools] – [Server Manager]. Server Manager starts. 2 Check [Windows Server Backup Features] in [Add Features] to install. 107 Chapter 5 Operations after OS Installation  Creating backup data Perform backup for the whole server configuration according to the following procedure. 1 Click [Start] – [Administrative Tools] – [Windows Server Backup]. 2 Select [Backup Once] from the operation menu. 3 Select [Full server] in [Select backup configuration]. 4 Select [Remote shared folder] in [Specify destination type].  Specify a shared folder or DVD drive on a server other than the device's server as a backup destination. 5 Select the options as required, and start backup. When backup has completed, the status (succeeded or failed) is displayed in the message part of the [Windows Server Backup] window. 5.2.2 Windows Server 2003 When installing Windows Server 2003, create the Automated System Recovery (ASR) set. To create it, an unused formatted floppy disk and media to store the backup file are required.  Only system information can be restored by using the Automated System Recovery (ASR) set that is created in this procedure. Data such as files created by customers are not included. Regular data backup using a backup device is recommended. For backup, refer to "9.5 Backup" (pg.251). 1 Click [Start] – [All Programs] – [Accessories] – [System Tool] – [Backup]. The [Backup or Recovery Wizard] window appears. 2 Click [Next]. The [Backup or Recovery] window appears. 3 Select [Create a backup of files and settings], and then click [Next]. The [Items to Create Backups] window appears. 4 Select [All the information in this computer], and then click [Next]. The [Backup Type, Destination and Name of the Backup File] window appears. 5 Enter a name and a destination for the backup file, and then click [Next]. The [Backup or Recovery Wizard Complete] window appears. 108 PRIMERGY BX620 S4 Server Blade User’s Guide 6 Click [Finish]. Backup process starts. 7 If a message prompts you to insert a floppy disk, insert the floppy disk and click [OK]. Automated system recovery disk is created. 8 When the process is completed, a message appears. Eject the floppy disk according to the message and put a label on it. Label example: Windows Automated System Recovery Disk: Backup.bkf, Created at 12:00 04/ 01/2003 9 Click [OK] to exit [Backup Utility]. 10 Click [Close] to close the [Backup Progress] window. An automated system recovery set has been created. Store the automated system recovery set just created just in case. 109 Chapter 5 Operations after OS Installation 5.3 Storing the System Setting Information Before starting operations, store the configuration information of the BIOS Setup Utility. By storing this information, the system can be recovered with the stored information in case of a system failure (such as when the information is deleted due to the drain of the built-in battery). Use Server Management Tools for storing and recovering the system configuration information.  The Management Blade has the similar function, which collectively manages the backup of multiple Server Blade setting information items. For details, refer to "BX600 Management Blade Hardware Guide".  Since the system configuration information is significant in maintaining the server, be sure to store the BIOS information after the following operations. In addition, save the stored data. • When the information is changed with the BIOS Setup Utility • When the hardware configuration of this server is changed (e.g. a CPU, memory, internal hard disk unit or expansion card is added, removed or changed)  As the stored system configuration information will be used during maintenance, etc., send it to your maintenance personnel.  Preparation for using Server Management Tools Use the Display/USB Extension Cable to connect to the USB floppy disk drive to the Server Blade. For the procedure to create "Server Management Tools" disk, refer to "5.4.2 Creating "Server Management Tools" Disk" (pg.116)  Cautions • Server Management Tools are for this Server Blade only. Do not use those tools on other systems. If they are used, the system can be damaged. • Only the information that is configured with the BIOS Setup Utility can be stored/recovered with Server Management Tools. The BIOS information in internal RAID devices cannot be stored/ recovered. • Make sure to start up the Server Blade with the "Server Management Tools" disk before running Server Management Tools. Do not run Server Management Tools on the server started from the hard disk or by the other floppy disks. Otherwise, the system may be corrupted. • Do not eject a floppy disk while the floppy disk access LED is on. Such an action may lead not only to corruption of the floppy disk data but also an unstable state of the system. • If an error message appears while running Server Management Tools, respond to the message according to " Server Management Tools error messages" (pg.236). 110 PRIMERGY BX620 S4 Server Blade User’s Guide 5.3.1 How to Store the BIOS Information with Server Management Tools Store the BIOS information according to the following procedures:  Before operating, if the ServerView "OS Boot Monitoring" function is enabled, disabled it (it is "Disabled" by default). If you start up the system while the "OS Boot Monitoring" function remains effective, the operation of the server may become unpredictable at such times as an abrupt power interruption or restart. If it is necessary to operate the server with the "OS Boot Monitoring" function enabled, enable the function after storing the BIOS information. For details of ServerView, refer to "ServerView User's Guide". 1 Turn on the server and insert the "Server Management Tools" disk into the floppy disk drive. The window for selecting a keyboard appears. Please select: 1 = JP Keyboard 2 = US Keyboard Your selection 2 Select a keyboard. Select "1" for the Japanese keyboard or "2" for the English keyboard. The Japanese keyboard is selected by default. 3 When the DOS prompt window appears, enter the following command and press the [Enter] key. A:\SMT>read.bat  If storing has already been performed with Server Management Tools, the stored file must exist in the floppy disk. In this case, overwriting the file may lead to incompletion of BIOS information recovery. Move the file to another floppy disk, rename the file, or delete it by executing the following command. A:\SMT\>deldat.bat [Enter] 4 If the BIOS information is stored correctly, the following message appears. NORMAL END 5 Check that the storing information file is created. Enter the following command and press the [Enter] key. A:\SMT\>dir Check that "SAVECMOS.BIN" and "nvram.enu" are created. Storing procedure is completed. The server can now be turned off safely. 111 Chapter 5 Operations after OS Installation 5.3.2 How to Recover the BIOS Information with Server Management Tools If the information configured with the BIOS Setup Utility was deleted due to a drain of the built-in server battery, etc., restore the BIOS information according to the following procedures:  Do not turn off the server during a program run.  Before starting the system, if the ServerView "OS Boot Monitoring" function is enabled, disable it (it is "Disabled" by default). If you start up the system while the "OS Boot Monitoring" function remains effective, the operation of the server may become unpredictable at such times as an abrupt power interruption or restart. If the server is operated with the "OS Boot Monitoring" function enable, enable the function again before resuming operation. For details of ServerView, refer to "ServerView User's Guide". 1 Turn on the server and insert the "Server Management Tools" disk into the floppy disk drive. The window for selecting a keyboard appears. Please select: 1 = JP Keyboard 2 = US Keyboard Your selection 2 Select a keyboard. Select "1" for the Japanese keyboard or "2" for the English keyboard. The Japanese keyboard is selected by default. 3 When the DOS prompt window appears, enter the following command and press the [Enter] key. A:\SMT\>dir Check that BIOS save information files "SAVECMOS.BIN" and "nvram.enu" are stored in the floppy disk. 4 Enter the following command and press the [Enter] key to recover BIOS information. A:\SMT\>write.bat 5 If the BIOS information is recovered correctly, the following message appears. NORMAL END 6 The BIOS information will be enabled after the next system restart. Restart the server. Perform Step 1 to display the DOS prompt window. The recovery procedure has been completed. The server can now be turned off safely. 112 PRIMERGY BX620 S4 Server Blade User’s Guide 5.4 Creating Maintenance Tools This section explains how to create tools for maintaining the server. Maintenance tools are created with the FloppyBuilder function of ServerStart. With the FloppyBuilder function of ServerStart, you can create the following tools: • "Server Management Tools" disk • DOS floppy disks The FloppyBuilder can be used under environments such as: • the ServerStart system started on a client computer (recommended) • the system started on the server using the PRIMERGY Startup Disc  When creating the tools on a client computer, install ServerStart on the computer beforehand. If ServerStart of a different version is installed in the computer, make sure to uninstall the ServerStart. Then perform installation again. For details on how to uninstall ServerStart, refer to " Uninstalling ServerStart" (pg.115). 5.4.1 Installing ServerStart Install ServerStart on a client computer when creating a drive disk using FloppyBuilder function.  System requirements for client computers Client computers must satisfy the following requirements. Hardware Personal computers operated with Windows Vista or Windows XP Professional (A DVD drive and minimum 10MB free disk space are required.) Software Microsoft® Internet Explorer 5.5 or later Using ServerStart on the server  ServerStart can be installed to the server, Windows Server 2008 (32-bit) or Windows Server 2003 employed. Install ServerStart in accordance with this chapter. Note that ServerStart is not available to the server where Windows Server 2008 (64-bit) or Windows Server 2003 x64 is installed. 1 Insert the PRIMERGY Startup Disc into the client computer. The [PRIMERGY Startup Disc] window appears. 113 Chapter 5 Operations after OS Installation 2 Click [ServerStart Vn.nnn]. The ServerStart version currently being used is displayed in "Vn.nnn". The [Fujitsu Siemens ServerStart] window appears.  The massage "Do you want to run or save this file?" may appear depending the OS in use. Follow as below. 1. Click [Run]. A massage appears that "The publisher could not be verified. Are you sure you want to run this software?" 2. Click [Run]. Execute "SeStSetup.exe" in the disk when [Fujitsu ServerStart Setup] window is not displayed. 3 Check the checkbox of [Classic] only and click [OK]. The Setup window appears. 4 Click [Next]. The [License Agreement] window appears. 5 Select [I accept the license agreement] and click [Next]. The [User Information] window appears. 114 PRIMERGY BX620 S4 Server Blade User’s Guide 6 Enter the user information of the software and click [Next]. The [Destination Folder] window appears. 7 Specify the installation folder and click [Next]. To change the installation folder, click [Browse] and select the folder. The [Ready to Install the Application] window appears. 8 Click [Next]. Installation is executed.  If a message prompts you to restart the system before or after installation, eject the disc and restart the system according to the message. When the system restarts, insert PRIMERGY Startup Disc and start installation again. If the "This program does not respond." message appears during restart operation, click [Exit] to continue the restart operation. When the installation is completed, the completion window appears. 9 Click [Exit]. ServerStart has been installed to the client computer.  Uninstalling ServerStart Uninstall ServerStart on the client computer according to the following procedure when necessary. 1 Click [Start] – [All Programs] – [Fujitsu Siemens ServerStart] – [Uninstall ServerStart]. 2 Click [OK]. When the uninstallation is executed successfully, ServerStart is deleted. 115 Chapter 5 Operations after OS Installation 5.4.2 Creating "Server Management Tools" Disk Start up ServerStart and confirm that the FloppyBuilder window is displayed. 1 Click [Server Management Tools]. 2 Click the tool to be created. Insert the prepared floppy disk by following the message. 3 Perform the subsequent operations according to the messages on the window. The floppy disk will be formatted automatically and file copying will start. The respective tools will be created automatically. When a message appears indicating that the disk is created, click [OK] and eject the disk. 4 Fill the following items on the label of the floppy disk. • The model of the server • Version and Level of the Server Management Tools • Date of the floppy disk created 5.4.3 Creating a DOS Floppy Disk For DOS data stored into the floppy disk, refer to the file in the following folder of the PRIMERGY Startup Disc. [CD/DVD drive]: \FreeDOS To create a DOS floppy disk, you need an unused floppy disk. Prepare it in advance. 1 Click [FloppyBuilder]. For details on procedures for starting up ServerStart, refer to " Starting ServerStart" (pg.72). 2 Click [DOS Diskette]. Insert the prepared floppy disk by following the message. 3 Perform the subsequent operations according to the messages on the window. The floppy disk will be formatted automatically and file copying will start. The DOS floppy disk will be created automatically. When a message appears indicating that creating the disk is completed, click [OK] and eject the disk. 116 PRIMERGY BX620 S4 Server Blade User’s Guide 5.5 Notes Before Operating the Server This section explains the settings required before starting to operate the server. For details on the settings, refer to the following URL. http://www.microsoft.com/technet/prodtechnol/exchange/2003/Library/default.mspx  If a LAN card or 1 Gbit/s Ethernet I/O Module was added, install a driver according to "4.3 Installing the LAN Driver" (pg.89).  To connect optional SCSI devices, refer to "Chapter 7 Installing Internal Options" (pg.171).  For the settings for the installed High Reliability Tools, refer to "Chapter 6 High Reliability Tools" (pg.163) and the manuals of each application.  For notes on ServerView security, refer to "Security" in "1.1.7 Note" in the "ServerView User's Guide". 5.5.1 Auto-run Function from CD/DVD Drives Perform the following procedures to change the settings of the auto-run function from the CD/DVD drives after server installation: 1 Make the registry editable, and change the value of AutoRun of the following registry key: HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\CDRom To enable auto-run, set the value of AutoRun to "1", and to disable auto-run, set the value to "0". 2 Restart the system. The setting is enabled after the system is restarted. 5.5.2 Drive Letter Assignment in Expert Mode In expert mode, you cannot specify a drive letter to a particular partition arbitrarily. Drive letters specified with Disk Manager in expert mode will be sequentially assigned from the first partition with "C, D, E..." when installation is completed, and an unused drive letter will be assigned to the CD-ROM drive. To change the drive letter, perform the following procedures after installation.  You cannot change the drive letters for the system and boot drive. 117 Chapter 5 Operations after OS Installation  For Windows Server 2003 1 Click [Start] – [Administrative Tools] – [Computer Management]. 2 Click [Disk Management]. 3 Right-click the partition to change the letter and click [Change Drive Letter and Path]. The [Change Drive Letter and Path] window appears. 4 Click [Edit]. The [Change Drive Letter or Path] window appears. 5 Change the drive letter. 5.5.3 Notes on Advanced Uninterruptible Power Supply (UPS) Note the following points when using an advanced uninterruptible power supply (referred to as UPS afterward).  UPS shutdown time setting Specify enough time for the UPS power-off time (time from the shutdown direction to the actual poweroff). If this time is set insufficiently, the power will be cut off before system shutdown, which may result in destruction of data. For more details, refer to the manuals for UPS and UPS management software.  Power supply control by UPS The following settings are required to power the server on automatically using the UPS management software (PowerChute Network Shutdown, PowerChute Business Edition) at power recovery or during scheduled operation. For details, refer to the manuals for UPS and UPS management software. 1 Start ServerView, and click [Recovery] – [ASR] in the [ServerView] window. The [ASR] window appears. 2 Click the [Restart Settings] tab and set [Action After Power Failure] to [Always Restart Server]. For details of the setting procedure, refer to "3.4 Serious Error Handling (ASR)" in "ServerView User's Guide". 118 PRIMERGY BX620 S4 Server Blade User’s Guide 5.5.4 Using Network Startup (PXE) The Server Blade obtains a boot image via network, and supports PXE (Preboot eXecution Environment) to be booted. For more details on setting, refer to " Booting the Server Blade with PXE" (pg.37).  Be sure to install ServerView to control the power supply via a LAN.  When booting the Server Blade with PXE, turn on the Server Blade power one minute or more after the main power of the Chassis was turned on. Turning on the Server Blade power just after the main power was turned on may cause PXE not to boot due to the Switch Blade not having been started.  The PXE boot function is not available for the LAN port of the 1 Gbit/s Ethernet I/O Module. 5.5.5 Changing the system drive size (only for Windows Server 2008) For Windows Server 2008, the partition size can be extended or reduced after installation has completed.  Extending the partition size of a system drive To extend the partition size of a system drive, perform the following procedure. 1 Log on to the server with administrator privileges. 2 Click [Start] – [All Programs] – [Administrative Tools] – [Server Manager]. Server Manager starts. 3 Double-click [Storage] – [Disk Management]. The [Disk Management] window appears. 4 Right-click the volume to be extended in [Disk Management], and click [Extend Volume]. The [Welcome to the Extend Volume Wizard] window appears. 119 Chapter 5 Operations after OS Installation 5 Click [Next]. The [Select Disks] window appears. 6 Specify the desired size in [Select the amount of space in MB].  The total value of the current partition size and the value that is specified in [Select the amount of space in MB] is displayed in [Total volume size in megabytes (MB)]. Specify the value so that the total of the volume sizes becomes a partition size to be created.  The maximum value that can be specified in [Select the amount of space in MB] is displayed in [Maximum available space in MB]. 7 Click [Next]. The [Completing the Extend Volume Wizard] window appears. 8 Check the disk size and click [Finish]. The [Disk Management] window appears. 9 Click [Exit] in the [File] menu. Server Manager finishes.  Reducing the partition size of system drive When reducing the partition size of system drive, perform the following procedures. 1 Log on to the server with administrator privileges. 2 Click [Start] – [All Programs] – [Administrative Tools] – [Server Manager]. Server Manager starts. 3 Double-click [Storage] – [Disk Management]. The [Disk Management] window appears. 120 PRIMERGY BX620 S4 Server Blade User’s Guide 4 Right-click the volume to be reduced, and click [Shrink Volume]. The [Shrink :] window appears.  Size of available shrink space can be restricted if snapshots or pagefiles are enabled on the volume. 5 Specify the desired size in [Enter the amount of space to shrink in MB].  The partition size after changing is displayed in [Total size after shrink in MB]. Specify the value so that the total size after reduction becomes the desired partition size.  The maximum value that can be specified in [Enter the amount of space to shrink in MB] is displayed in [Size of available shrink space in MB].  Click [Shrink] to start the shrinking process. Make sure to check whether the proper value is specified in [Total size after shrink in MB] before clicking [Shrink]. 6 Click [Shrink]. Shrinking is executed, the [Disk Management] window appears. 7 Click [Exit] in the [File] menu. Server Manager finishes. 121 Chapter 5 Operations after OS Installation 5.5.6 Other Notes on Operation  Unnecessary files After OS installation is completed, folders named Runonce and Runonce 2 may be left in the drive where the OS is installed. Delete these folders since you do not need them for the system operation.  Notes on 24-hour operation  Automated system operation To provide an extra margin of safety against unintentional damage, introduce disaster-prevention measures in the office and keep disaster prevention personnel (such as a security guard or janitor) in the building.  Unintentional power-off prevention We recommend the installation of a special power supply device (such as a distribution board) to prevent unplanned power shut-offs.  Notes on KVM switch • After the KVM switching, you may not be able to enter the first key entry using the keyboard. Enter the key entry again. • In the Windows or Linux system, if the KVM switch is operated while the [NumLock], [CapsLock], and [ScrollLock] LEDs are on by pressing their keys on the keyboard connected to the Chassis, those LEDs may go off. To return the LEDs lamps to the normal state, press the [NumLock], [CapsLock], and [ScrollLock] keys again. • If KVM switch is operated frequently during Linux booting, the keyboard or mouse may not be used after booting, without being recognized. Reboot the server so that the keyboard or mouse will operate properly. When either the keyboard or mouse cannot be used, log on remotely via the network, then reboot the server. • If KVM switching is frequently performed during Windows booting, the keyboard or mouse may be recognized improperly, and i8042prt.sys may generate error logs in the event viewer system log. If the keyboard and mouse operate properly, those logs can be ignored. If they do not operate properly, restart the system and they will be recognized normally. 122 PRIMERGY BX620 S4 Server Blade User’s Guide 5.6 LAN Driver Advanced Setup [BACS] BACS is an integrated GUI application consisting of programs such as BASP (Broadcom Advanced Server Program) that provides the load balancing feature, etc., by teaming up multiple adapters. BACS is used in the following situations: • Create a Team using an onboard LAN and 1Gbit/s Ethernet I/O Module (PGLND201) • Perform advanced setup for an onboard LAN and 1Gbit/s Ethernet I/O Module (PG-LND201) Use of Intel® PROSet  Use Intel® PROSet (pg.151) to perform the following setup for LAN cards (PG-2861L) • Use the Teaming function between LAN cards (PG-2861L) • Setup a VLAN using LAN cards (PG-2861L) • Use the Jumbo frame using LAN cards (PG-2861L) • Perform other advanced settings for LAN cards (PG-2861L) 5.6.1 BACS Installation If [Broadcom Control Suite 2] or [Broadcom Control Suite 3] is not displayed in the [Control Panel], install BACS according to the following installation procedures:  For Windows Server 2008 1 Execute the following file contained in the PRIMERGY Startup Disc. For Windows Server 2008 (32-bit) [CD/DVD drive]: \DRIVERS\LAN\Broadcom\Onboard\MgmtApps\w2k8\setup.exe For Windows Server 2008 (64-bit) [CD/DVD drive]: \DRIVERS\LAN\Broadcom\Onboard\MgmtApps\w2k8x64\setup.exe The installer starts up. 2 Click [Next]. License agreement window appears. 3 Select [I accept the terms in the license agreement] and click [Next]. Custom Set up window appears. 4 Check that [Control Suite] and [BASP] are selected, and click [Next]. Proceed with the installation by following the instructions in the window. 123 Chapter 5 Operations after OS Installation  For Windows Server 2003 x64 1 Execute the following file contained in the PRIMERGY Startup Disc. [CD/DVD drive]: \DRIVERS\LAN\Broadcom\Onboard\MgmtApps\x64\setup.exe The installer starts up. 2 Click [Next]. License agreement window appears. 124 PRIMERGY BX620 S4 Server Blade User’s Guide 3 Click [I accept the terms in the license agreement] and click [Next]. Custom Set up window appears. 4 Click [Next]. Proceed the installation by following the window instructions. 125 Chapter 5 Operations after OS Installation  For Windows Server 2003  If the OS is installed using ServerStart, "BACS" is already installed with the driver. If the OS is installed manually, BACS will not be installed. 1 Execute the following file contained in the PRIMERGY Startup Disc. [CD/DVD drive]: \DRIVERS\LAN\Broadcom\Onboard\MgmtApps\IA32\setup.exe The installer starts up. 2 Proceed the installation by following the window instructions. When the window below appears during the installation procedure, check [BASP] and click [Next]. 126 PRIMERGY BX620 S4 Server Blade User’s Guide 5.6.2 Teaming In this Server Blade, teaming is possible with any Intel/Broadcom adapter.  For Windows Server 2008  Creating a team 1 Log in with Administrator or same privileges. 2 Click [Start] – [All Programs] – [Broadcom] – [Broadcom Control Suite 3]. Broadcom Control Suite 3 starts. 3 Click [Team Management]. 127 Chapter 5 Operations after OS Installation 4 Click [Create a Team] in the [Teams] menu. The [Welcome to the Broadcom Teaming Wizard] window appears. 5 Click [Next]. The [Creating/Modifying a Team: Team Name] window appears. 128 PRIMERGY BX620 S4 Server Blade User’s Guide 6 Enter a team name, and click [Next]. The [Creating/Modifying a Team: Team Name: Team Type] window appears. 7 Select the team type, and click [Next]. The following is an explanation for when selecting [Smart Load Balancing (TM) and Failover (SLB)] as an example. The [Creating/Modifying a Team: Assigning Team Members] window appears. 8 Select the adapter to be incorporated in the Team from the [Available Adapters] list, and click [Add]. The selected adapter is added in the [Team Members] list. 129 Chapter 5 Operations after OS Installation 9 Click [Next]. The [Creating/Modifying a Team: Designating a Standby Member] window appears. 10 Set for the standby member, and click [Next]. The [Creating/Modifying a Team: Configure LiveLink] window appears.  Auto-Fallback can be selected when using the Team as a standby member.  LiveLink does not support Auto-Fallback. LiveLink detects loss of network connectivity beyond the switch and routes traffic only through team members that have a live link. 130 PRIMERGY BX620 S4 Server Blade User’s Guide 11 Specify whether or not to configure LiveLink, and click [Next]. The operation varies between " When selecting [Yes]" (pg.131) and " When selecting [No]" (pg.131). When selecting [No] The [Creating /Modifying a VLAN: Configure VLAN Support] window appears. Go to Step 12. When selecting [Yes] The [Configure LiveLink(TM) attributes] window appears. Perform the following procedure. 131 Chapter 5 Operations after OS Installation 1. Enter values for the following setting items, and click [Edit Target IP Address...]. • Probe interval (seconds) Specify the probe interval (seconds) between 1 to 60. • Probe maximum retries Specify the Probe maximum retries between 1 to 10. • Probe VLAN ID When setting tag VLAN for probe of LiveLink, specify the value between 0 to 4096. The following window appears. 2. Specify the Target IP address, and click [OK]. Returns to the [Configure LiveLink(TM) attributes] window.  Entering an IP address for Target1 is required. Up to four Targets can be specified. 3. Click [Next]. The [Configure the IP address for each team member] window appears. 4. Select the team member to specify the IP address on the [Team Members] list. 132 PRIMERGY BX620 S4 Server Blade User’s Guide 5. Click [Edit Member IP Address...]. The following window appears. 6. Enter the IP address of the team member for LiveLink in [IP address], and click [OK]. Returns to the [Configure the IP address for each team member] window. 7. Set IP addresses repeating Steps 4 to 6 for all team members on the [Team Members] list. 8. Click [Next]. The [Creating /Modifying a VLAN: Configure VLAN Support] window appears. 133 Chapter 5 Operations after OS Installation 12 Specify whether or not to create a VLAN, and click [Next]. If creating, create a VLAN by following the instructions displayed in the window. When not creating, the following completion window appears. 13 Click [Finish]. The following window appears. 134 PRIMERGY BX620 S4 Server Blade User’s Guide 14 Click [Yes]. The window returns to the initial window. When the team settings have completed, the multiple adapters that were selected above are displayed as one virtual adapter. Set the IP address in this virtual adapter.  Deleting a team 1 Click [Start] – [All Programs] – [Broadcom] – [Broadcom Control Suite 3]. Broadcom Control Suite 3 starts. 2 Select [Teams] – [Delete Team]. The following window appears. 3 Click [Yes] to delete the selected team. 135 Chapter 5 Operations after OS Installation  Saving a team 1 Create a team. " Creating a team" (p.127) 2 Click [File] – [Team Save As]. 3 Click [Yes] to save the created team.  Restoring a team 1 Call the saved team by clicking [File] – [Team Restore]. The following window appears. 2 Click [Apply / Exit]. The following window appears. 3 Click [Yes] to restore the team. 136 PRIMERGY BX620 S4 Server Blade User’s Guide  For Windows Server 2003  Creating a team 1 Click [Start] – [All Programs] – [Broadcom] – [Broadcom Control Suite2]. Broadcom Control Suite2 starts. 2 Click [Tools] – [Create a Team]. The [Broadcom Teaming Wizard] window appears. 137 Chapter 5 Operations after OS Installation 3 Click [Next]. The [Creating/Modifying a Team: Team Name] window appears. 4 Assign your team a unique name, and click [Next]. The [Creating/Modifying a Team: Team Type] window appears. 138 PRIMERGY BX620 S4 Server Blade User’s Guide 5 Select the type of team you want to create, and click [Next]. An explanation for when [Smart Load Balancing (TM) and Failover (SLB)] is selected is explained in the example. The [Creating/Modifying a Team: Assigning Team Members] window appears. 6 Specify which adapters to include in the team, and click [Next]. The [Creating/Modifying a Team: Designating a Standby Member] window appears. 139 Chapter 5 Operations after OS Installation 7 Specify whether you want a standby member for the team, and click [Next]. The [Creating/Modifying a Team: Configuring LiveLink] window appears.  You can select Auto-Fallback Disable Mode if you use the member as a standby member.  LiveLink feature is not supported if Auto-Fallback Disable Mode is enabled. LiveLink detects loss of network connectivity beyond the switch and routes traffic only through team members that have a live link. 8 Specify whether you want LiveLink, and click [Next]. The [Creating/Modifying a VLAN: Configure VLAN Support] window appears. 140 PRIMERGY BX620 S4 Server Blade User’s Guide 9 Specify whether or not to create a VLAN, and click [Next]. When creating, create a VLAN by following the instructions displayed in the window. When not creating, the following completion window appears. 10 Click [Finish]. The following window appears. 11 Click [Yes]. The following window appears. 141 Chapter 5 Operations after OS Installation 12 Click [OK]. Returns to the initialization screen. Some adapters that have been selected are displayed as one virtual adapter when completing the team settings.  Deleting a team 1 Click [Start] – [All Programs] – [Broadcom] – [Broadcom Control Suite2]. Broadcom Control Suite2 starts. 2 Click [Tools] – [Delete a Team] to delete a Team.  Saving a team 1 Create a Team. " Creating a team" (p.137) 2 Click [File] – [Team Save As] to save a Team you have created by now.  Restoring a team 1 Click [File] – [Team Restore] to open a Team you restored before. 2 And click [File] – [Apply] to complete a Team restore. 142 PRIMERGY BX620 S4 Server Blade User’s Guide 5.6.3 VLAN Setup Procedure  For Windows Server 2008 1 Click [Start] – [Control Panel] – [Broadcom Control Suite 3]. BACS starts. 2 Right-click a LAN adapter or the Team name of a Teamed Up adapter, and click [Add VLAN] from the displayed menu. The [Welcome to the Broadcom Teaming Wizard] window appears.  A LAN adapter is displayed with a mark.  The Team name of a Teamed Up adapter is displayed with a mark. 143 Chapter 5 Operations after OS Installation 3 Click [Next]. The [Creating/Modifying a VLAN: Naming] window appears. 4 Specify a VLAN name, and click [Next]. The [Creating/Modifying a VLAN: Tagging] window appears.  A VLAN Name that has already been used cannot be used. Enter another name. 144 PRIMERGY BX620 S4 Server Blade User’s Guide 5 Select the VLAN type to be set, and click [Next]. When selecting [Untagged] The [Creating/Modifying a VLAN: Additional VLANs] window appears. Go to Step 6. When selecting [Tagged] The [Creating/Modifying a VLAN: Tag Value] window appears. 1. Specify the tag value of VLAN between 1 to 4094, and click [Next]. 2. Click [OK]. The [Creating/Modifying a VLAN: Additional VLANs] window appears. 145 Chapter 5 Operations after OS Installation 6 When creating more VLANs, click [Yes]. When finished adding VLANs, select [No] and click [Next]. When selecting [Yes] Repeat Steps 3 to 5. When selecting [No] The following window appears. 7 When adding teams has completed, select the process in the window above and click [Finish]. The following window appears. 8 Click [Yes]. 146 PRIMERGY BX620 S4 Server Blade User’s Guide  For Windows Server 2003 1 Click [Start] – [Control Panel] – [Broadcom Control Suite 2]. BACS starts. 2 Right-click a LAN adapter or the Team name of a Teamed Up adapter, and click [Add VLAN] from the displayed menu. The [Welcome to the Broadcom Teaming Wizard] window appears.  A LAN adapter is displayed with a mark.  The Team name of a Teamed Up adapter is displayed with a mark. 147 Chapter 5 Operations after OS Installation 3 Click [Next]. The [Creating/Modifying a VLAN: Naming] window appears. 4 Enter the VLAN Name, click [Next]. The [Creating/Modifying a VLAN: Tagging] window appears.  You cannot use a "VLAN Name" that has already been used. Enter another set value. 148 PRIMERGY BX620 S4 Server Blade User’s Guide 5 Select the VLAN type to be set, and click [Next]. When selecting "Untagged" The [Creating/Modifying a VLAN: Additional VLANs] window appears. Skip to the Step 7. When selecting "Tagged" The [Creating/Modifying a VLAN: Tag Value] window appears. 1. Specify the VLAN tag value (1 to 4094), and click [Next]. 2. Click [OK]. The [Creating/Modifying a VLAN: Additional VLANs] window appears. 6 Select [Yes] when adding another VLAN or select [No] when adding additional VLANs has completed, and click [Next]. When selecting [Yes] Repeat the Step 3 through Step 5. 149 Chapter 5 Operations after OS Installation When selecting [No] The following window appears. 7 When adding a team has completed, select the procedure in the above window, and click [Finish]. The following window appears. 8 Click [Yes]. The following window appears. 9 Click [OK]. 150 PRIMERGY BX620 S4 Server Blade User’s Guide 5.7 LAN Driver Advanced Setup [Intel® PROSet] "Intel® PROSet" is a tool for configuring details on the LAN driver. This is used in the following cases. • Use the Teaming function between LAN cards (PG-2861L) • Setup a VLAN using LAN cards (PG-2861L) • Use the Jumbo frame using LAN cards (PG-2861L) • Perform other advanced settings for LAN cards (PG-2861L) 5.7.1 Intel® PROSet Installation If the tabs such as [Link], [Teaming] and [VLANs] are not displayed in the property of LAN adapters which can be selected from the [Device Manager], install Intel® PROSet according to the following installation procedures:  For Windows Server 2008 1 Execute the following file in the PRIMERGY Startup Disc. For Windows Server 2008 (64-bit) [CD/DVD drive]: \Drivers\LAN\Intel\APPS\PROSETDX\Vistax64\DxSetup.EXE For Windows Server 2008 (32-bit) [CD/DVD drive]: \Drivers\LAN\Intel\APPS\PROSETDX\Vista32\DxSetup.EXE 2 Click [Next]. 3 Select [I accept the license agreement] and click [Next]. 4 Confirm only the following two items are checked and click [Next]. • Intel® PROSet for Windows Device Manager • Advanced Network Services 5 Click [Install]. 6 Click [Finish]. 151 Chapter 5 Operations after OS Installation  For Windows Server 2003 1 Execute the following file in the PRIMERGY Startup Disc. For Windows Server 2003 x64 [CD/DVD drive]: \Drivers\LAN\Intel\APPS\PROSETDX\Winx64\DxSetup.EXE For Windows Server 2003 [CD/DVD drive]: \Drivers\LAN\Intel\APPS\PROSETDX\Win32\DxSetup.EXE 2 Click [OK]. 3 Click [Next]. 4 Click [Accept]. 5 Confirm only the following two items are checked and click [Next]. • Intel® PROSet for Windows Device Manager • Advanced Network Services 6 Click [Install]. 7 Click [Close]. 5.7.2 Notes on Referring to the Intel® PROSet Help Topics When referring to help topics, note the following points. • Do not use the driver downloaded from the Intel Corporation online service page on this server. • If the descriptions in the help and this manual vary, give priority to this manual. • The LAN cards names in Help corresponds to the cards as follows: table: LAN cards names in Help LAN cards names in Help Corresponding LAN devices PRO/1000 Server PG-2861L PRO/1000 Adapter PG-2861L PRO/1000 Copper Adapter PG-2861L • The controller used for each device is as follows: table: Controller being used LAN device Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L) 152 Controller being used Intel® 82546EB PRIMERGY BX620 S4 Server Blade User’s Guide 5.7.3 Teaming  Teaming types Teaming has the following types. • Adapter Fault Tolerance (AFT) Adapter Fault Tolerance (AFT) is a technology to make the link between the server and switches redundant by using multiple LAN ports. When a failure occurs in the link being used (Primary Link), the communication continues by switching the process to the standby link (Secondary Link) without interrupting. For AFT, all ports in the team must be connected to the same switch. • Adaptive Load Balancing (ALB) Adaptive Load Balancing (ALB) is a technology that distributes the sending and receiving data to multiple LAN ports to improve the performance in addition to redundancy function of AFT (When "Receive Load Balancing (RLB)" in Advanced setting is set to "Disabled", the reception is done only in the Primary Link). For ALB, all ports in the team must be connected to the same switch as well as AFT. • Switch Fault Tolerance (SFT) Switch Fault Tolerance (SFT) is a redundancy function equal in configuration to AFT when LAN ports are connected to a separate switch. SFT switches the link to be used between LAN ports and switches that are connected to the LAN ports when a failure occurs. However, a failure in links outside of the switches (←, ↓, and → in the figure below) cannot be detected. ← Switch ↓ → Switch PRIMERGY • Static link aggregation Select this mode when connecting a team to a Cisco FEC/GEC compliant switch or a switch that supports IEEE802.3ad-Draft Static. Switch settings are also necessary. All ports in the team must be connected to the same switch. • IEEE802.3ad dynamic link aggregation (only for Windows Server 2008) Select this mode when connecting a team to a switch which supports IEEE802.3ad compliant Link Aggregation Control Protocol (LACP). In this mode, all adapters must run at the same speed, and all ports in the team must be connected to the same switch. Also, this mode is only available for Teaming on the LAN card. 153 Chapter 5 Operations after OS Installation  Notes When using the Teaming function, note the following points. • For AFT/ALB/Static link/Dynamic link type, up to four LAN ports can be incorporated into one team and two ports for a SFT type team. • Once a Team is created, virtual adapters (Team:(Team Name)) will be created in the [Device Manager] and [Network and Dial-up Connections] of the system. Do not disable or delete this virtual adapter from the [Device Manager] or [Network and Dial-up Connections]. When deleting a virtual adapter, make sure to use "Intel® PROSet". • When the Teaming function is being used, only the following protocols can be used: • For AFT/SFT/Static link/Dynamic link type: IP, NetBEUI, IPX (NCP), IPX (NetBIOS) • For ALB type: IP, IPX (NCP) • When the Teaming function is being used, Windows Load Balancing Service (WLBS) and Network Load Balancing (NLB) cannot be used. • If Static link type is selected, only the switch for link aggregation can be used. • When adding/deleting a Static link type member, perform such operation in a linked down state.  Only a link down error between a LAN card (onboard LAN) and the switch it connects with, and the equivalent errors lead to switching of the route. Therefore, if only the switch or LAN card (onboard LAN) is partially damaged and the route being used is normal at the link level, the route will not be switched in the team, but the communication using team may become an error.  For Windows Server 2008  Creating a team 1 Click [Start] – [Administrative Tools] – [Computer Management] to start Intel® PROSet. 2 Click [Network adapters] under [Device Manager] and double-click a LAN adapter to be incorporated in a team. 3 Click the [Teaming] tab, select [Team with other adapters] and click [New Team]. 4 Enter a team name and click [Next]. 5 Check the only LAN adapter to be incorporated in the Team and click [Next]. 6 Select a Teaming type with which a Team will be created, and click [Next]. Select the following depending on the Teaming type: • AFT type: "Adapter fault tolerance" • ALB type: "Adaptive load balancing" • SFT type: "Switch fault tolerance" • Static link type: "Static link aggregation" 154 PRIMERGY BX620 S4 Server Blade User’s Guide • Dynamic link type: "IEEE802.3ad dynamic link aggregation" 7 Click [Finish]. 8 Click [OK] to close the property window of the created Teaming adapter. 9 Click [OK] to close the property window of the LAN adapter. When the Teaming setting is complete, the following virtual adapter will be created. • "Team: (Team Name)" Upper protocols will be bound with the main virtual adapter. They cannot be bound with the LAN card included in a Team. The IP address can be set in the main virtual adapter.  Deleting a team When deleting a team, use Intel® PROSet according to the following procedure. 1 Click [Start] – [Administrative Tools] – [Computer Management] to start Intel® PROSet. 2 Click the [Setting] tab, and click [Delete Team]. The confirmation message appears. 3 Click [Yes]. 4 Restart the Server Blade.  For Windows Server 2003  Creating a team Follow the steps below to create a Team. 1 Log on to the Server Blade with administrator privileges. 2 Click [Start] – [Settings] – [Control Panel] – [Intel® PROSet Wired], and start Intel® PROSet. 3 Select a LAN adapter to incorporate in a Team and right-click it. 4 Click [Create New Team] in [Add to Team]. [Teaming Up Wizard] appears. 5 Select a Teaming type with which you want to create a Team. • AFT type: "Adapter fault tolerance" • ALB type: "Adaptive load balancing" • SFT type: "Switch fault tolerance" 155 Chapter 5 Operations after OS Installation • Static link type: "Static link aggregation" Do not select other team types. 6 Click [Next]. 7 Select a LAN adapter to incorporate in a Team and click [Next]. 8 Click [Finish]. 9 Click [OK] to exit Intel® PROSet. When the Teaming setting is completed, a virtual adapter "Intel® Advanced Network Services Virtual Adapter" will appear. Upper protocols will be bound with this virtual adapter. You cannot bind them with the LAN card consisting of a Team. The IP address should be specified in this virtual adapter. 10 Restart the Server Blade.  Deleting a team Follow the steps below to delete a Team. 1 Log on to the Server Blade with administrator privileges. 2 Click [Start] – [Settings] – [Control Panel] – [Intel®PROSet Wired], and start Intel® PROSet. 3 Select the OS to delete. 4 Click [Delete team]. The confirmation message appears. 5 Click [OK]. 6 Click [OK] to exit Intel® PROSet. 7 Restart the Server Blade.  Creating an AFT, ALB, or SFT team in Windows Server 2003 causes a virtual adapter (Intel® Advanced Network Service Virtual Adapter) to be created in [Device Manager], [Network and Dial-up Connections], or [Network Connection] of the system. However, do not disable or delete the virtual adapter from [Device Manager], [Network and Dial-up Connections], or [Network Connection]. When deleting the virtual adapter, make sure to use Intel® PROSet. 156 PRIMERGY BX620 S4 Server Blade User’s Guide  Event logs When AFT, ALB, or SFT is used, the following event logs will be generated (source: i ANSMiniport). table: Event log messages ID Type Message 6 Information The primary adapter has been initialized: (Adapter name) 7 Information The adapter has been initialized: (Adapter name) 8 Information (Team name): The team has been initialized. 10 Information The current primary adapter is changed from the next adapter: (Adapter name) 11 Warning The next adapter link is not connected: (Adapter name) 12 Information The secondary adapter has a priority: (Adapter name) 13 Warning (Adapter name) has been disabled with a team. 14 Information The secondary adapter has been added to a team again: (Adapter name) 15 Information The next adapter link is connected: (Adapter name) 16 Error (Team name): The last adapter has been unlinked. Network connection has failed. 17 Information (Team name): The adapter has established a link again. The network connection has been recovered. 18 Information The primary adapter at the next priority level has been detected: (Adapter name) 19 Information The secondary adapter at the next priority level has been detected: (Adapter name) 20 Information The primary adapter at the next priority level is preferentially handled: (Adapter name) 21 Information The secondary adapter at the next priority level is preferentially handled: (Adapter name) 22 Warning The primary adapter could not detect the next probe: (Adapter name) Cause: The team may be divided into groups. 35 Warning (Team name) without one adapter is initialized. Confirm that all adapters exist and function. 38 Information (Adapter name) has been deleted from the team. 42 Warning (Adapter name) is not specified properly. The adapter cannot process the remote management function while being a network team.  Notes • When the teaming function normally starts running, event logs (ID = 6 to 8) are stored at boot of the system. This is not a problem; no action is required. • Once a Team is setup, plural warning logs (ID = 11) and event logs (ID =15, etc.) may be stored in the system log of the event viewer at boot of the system. This is not a problem; no action is required. 157 Chapter 5 Operations after OS Installation 5.7.4 VLAN A Virtual LAN (VLAN) is a collection of devices to connect to LAN, which are grouped in logical mode not physically. VLAN can specify a network segment that is available to a device. This enhances network performance and security. A VLAN has a function that logically groups users and devices, simplifying a network management between buildings. A VLAN is usually controlled by switch setting. A device can belong to only one VLAN for each LAN card. This driver enables you to configure multiple VLANs on one LAN card. This driver also supports the VLAN defined in IEEE802.1Q. PRIMERGY Server Switch (IEEE802.1Q support) VLAN10 VLAN20 Client Client VLAN10,20,30 VLAN30 Client Client LAN card Client Client  Notes When using a VLAN, note the following points. • When adding or deleting a VLAN, always use "Intel® PROSet". Do not disable or delete a VLAN from the [Device Manager] or [Network and Dial-up Connections]. • Up to ten VLANs can be set to a LAN port. • Up to four VLANs whose "NetBIOS over TCP/IP" is enabled can be set in the whole system. • On a VLAN, only use TCP/IP protocols. • When LLC and the LNDFC protocols are installed by the Fujitsu communication control service, these protocols are bound (connected) unconditionally. Therefore, release the bind of VLAN and these protocols in the system where these protocols and VLAN are installed at the same time.  For Windows Server 2008  Creating a VLAN 1 Click [Start] – [Administrative Tools] – [Computer Management] to start Intel® PROSet. 2 Click [Network adapters] under [Device Manager] and double-click a LAN adapter to setup a VLAN. 3 Click the [VLANs] tab, and click [New...]. 158 PRIMERGY BX620 S4 Server Blade User’s Guide 4 Specify [VLAN ID] and [VLAN Name]. Then click [OK]. The [VLAN ID] should be identical to the switch setting. 1 to 4094 can be specified. Any name can be specified as the [VLAN Name]. 5 Click [OK] to close the property window for the LAN adapter. When setup of the VLAN is complete, the following virtual adapter will be created. • "(LAN Adapter Name)-VLAN:(VLAN Name)" Upper protocols will be bound with the main virtual adapter. They cannot be bound with the LAN card configuring a VLAN. The IP address should be specified in the main virtual adapter.  Deleting a VLAN Follow the steps below to delete a VLAN. 1 Log on to the Server Blade with administrator privileges. 2 Click [Start] – [Settings] – [Control Panel] – [Intel® PROSet for Wired Connections] to start Intel® PROSet. 3 Select the VLAN to be deleted and click it. 4 Click [Delete VLAN]. The confirmation message appears. 5 Click [OK]. When an attempt is made to delete the last VLAN, the message will be displayed. Click [OK]. 6 Click [OK] to exit Intel® PROSet. 7 Restart the Server Blade.  For Windows Server 2003  Creating a VLAN Follow the steps below to create a VLAN. 1 Log on to the Server Blade with administrator privileges. 2 Set the port of the Switch Blade connected to each LAN port or the port of an external switching hub, so that a VLAN tag frame can be transferred. 3 Click [Start] – [Settings] – [Control Panel] – [Intel® PROSet Wired], and start Intel® PROSet. 159 Chapter 5 Operations after OS Installation 4 Select a LAN adapter to set up a VLAN and right-click it. A VLAN cannot be set to an adapter composing a team. 5 Click [Add VLAN]. 6 Specify [ID] and [Name]. Then click [OK]. The [ID] should be identical with the switch setting. The allowable range is 1 to 4094. The [Name] does not need to be identical with the switch setting. When the confirmation message appears, select [Yes]. 7 Repeat Steps 4 through 6 to set respective VLANs. 8 Click [OK] to exit Intel® PROSet. When configuring a VLAN is completed, a virtual adapter "Intel® Advanced Network Services Virtual Adapter" will appear. Upper protocols will be bound with this virtual adapter. You cannot bind them with the LAN card consisting a team. The IP address should be specified in this virtual adapter. 9 Restart the Server Blade.  Deleting a VLAN Follow the steps below to delete a VLAN. 1 Log on to the Server Blade with administrator privileges. 2 Click [Start] – [Settings] – [Control Panel] – [Intel® PROSet Wired], and start Intel® PROSet. 3 Select the VLAN to delete and click it. 4 Click [Delete VLAN]. The confirmation message appears. 5 Click [OK]. When an attempt is made to delete the last VLAN, the message will be displayed. Click [OK]. 6 Click [OK] to exit Intel® PROSet. 7 Restart the Server Blade. 160 PRIMERGY BX620 S4 Server Blade User’s Guide 5.7.5 Local Address Setting Follow the steps below to specify a local address.  For Windows Server 2008 1 Log on to the Server Blade with administrator privileges. 2 Click [Start] – [Administrative Tools] – [Computer Management], select [Device Manager], and then double-click Network Adapter. 3 Double-click the LAN adapter to be set, and click the [Advanced] tab. 4 Specify the local address to be set for [Locally Administered Address]. Enter 12 hexadecimal characters beginning with "02". 5 Click [OK] to exit Intel® PROSet. 6 Restart the Server Blade.  When returning to a global address, delete the value specified in step 4.  For Windows Server 2003 1 Log on to the Server Blade with administrator privileges. 2 Click [Start] – [Settings] – [Control Panel] – [Intel® PROSet Wired], and start Intel® PROSet. 3 Select a LAN adapter to set the local address and click the [Advanced] tab. 4 Specify a local address in [Locally Managed Address]. Enter 12 hexadecimal characters beginning with "02". 5 Click [OK] to exit Intel® PROSet. 6 Restart the Server Blade.  When returning to a global address, delete the value specified in step 4. 161 Chapter 5 Operations after OS Installation 5.7.6 Jumbo Frame  For Windows Server 2008 Gigabit Ethernet supports Jumbo Frame. When using Jumbo frame, construct the Jumbo frame network using only devices that support Jumbo frame, and apply the settings that will enable Jumbo frame. Configure setting for Jumbo frame according to the following procedures. 1 Log on to the Server Blade with administrator privileges. 2 Click [Start] – [Administrative Tools] – [Computer Management], select [Device Manager], and then double-click Network Adapter. 3 Double-click the LAN adapter to be set, and click the [Advanced] tab. 4 Specify the value to be used for [Jumbo Packets]. 5 Click [OK] to exit Intel® PROSet. 6 Restart the Server Blade.  For Windows Server 2003 1 Log on to the Server Blade with administrator privileges. 2 Click [Start] – [Settings] – [Control Panel] – [Intel® PROSet Wired], and start Intel® PROSet. 3 Select a LAN adapter to perform configuration and click the [Advanced] tab. 4 Set to the required value in [Jumbo Frame]. 5 Click [OK] to exit Intel® PROSet. 6 Restart the Server Blade. 162 Chapter 6 High Reliability Tools For stable PRIMERGY server operations, we recommend that high reliability tools be installed. This chapter explains the installation and necessary settings of high reliability tools. 6.1 6.2 6.3 6.4 RAID Management Tool . . . . . . . . . . . . . . . . . . . . . . . . . Server Monitoring Tool [ServerView] . . . . . . . . . . . . . . . . Maintenance Support Tool [HRM/server] . . . . . . . . . . . . . Solving Problems Early [DSNAP] . . . . . . . . . . . . . . . . . . . 164 165 168 169 163 Chapter 6 High Reliability Tools 6.1 RAID Management Tool RAID Management Tool is software that performs array configuration, disk initialization and disk array monitoring. Refer to the manual in the Array Controller Document & Tool CD for installation procedures and use. For the manual of the SAS RAID Ctrl to be used, refer to "2.3.2 Notes on Configuring RAID" (pg.42). OS installation using ServerStart  If the OS is installed using ServerStart, RAID Management Tool is installed with the OS and other high reliability tools. 6.1.1 Before starting operation After installing the OS in the server, perform the following settings. For details, refer to the manual in the Array Controller Document & Tool CD.  Setting for an array administrator account Set an array administrator account for the RAID management tool (ServerView RAID). A Windows user account is required when using ServerView RAID. Create the group "raid-adm", and create an account with any name for an administrator of the array in this group.  Setting for the HDD check scheduler When using the SAS RAID Ctrl (MegaRAID SAS), change the setting for the HDD check scheduler according to the operation as required. It is set to 12:00 for everyday as default. 164 PRIMERGY BX620 S4 Server Blade User’s Guide 6.2 Server Monitoring Tool [ServerView] ServerView constantly monitors the status of the servers' hardware in the network and provides a console with which the administrator can check the status of all the servers at a glance. When using ServerView, the server hardware is monitored all the time. If an error that could cause trouble is detected, the administrator is notified in real-time. This allows the server administrator to remove a system error early and avoid trouble.  For notes on ServerView security, refer to "Security" in "1.1.7 Note" in the "ServerView User's Guide".  Importance of monitoring the server with ServerView For safe operation of the server, always monitor the server using ServerView. Even if the server is operated in the redundancy configuration, overlooking or neglecting errors could result in a system stop or data loss. As soon as one constituent part of the redundancy configuration fails, the corresponding countermeasures must be taken. For that reason, monitoring the server with ServerView is necessary. If ServerView is not applied, the following very serious problems may occur.  RAID error monitoring ServerView notifies of the RAID errors. In an environment where ServerView is not applied, the administrator is not notified of the RAID errors. Leaving the RAID error unattended may lead to a system stop with multiple dead drives.  Memory monitoring ServerView monitors the memory. In an environment where ServerView is not applied, a memory single-bit error cannot be detected during operation. In order to detect the error, the server must reboot to run the BIOS Setup Utility or the Server Management Tools. Leaving this error unattended may lead to multiple-bit errors and a system stop.  Fan monitoring ServerView monitors the fan. In an environment where ServerView is not applied, fan irregularities (failure/stop) cannot be detected during operation. In order to detect the problem, the server must reboot to run the BIOS Setup Utility or the Server Management Tools. Leaving the fan problem unattended may lead to overheating inside the server and a system stop. 165 Chapter 6 High Reliability Tools  Temperature monitoring ServerView monitors the temperature. In an environment where ServerView is not applied, the increased temperature inside the server, due to the fan problem described above, cannot be detected and the system stop cannot be prevented. In order to detect the problem, the server must reboot to run the BIOS Setup Utility or the Server Management Tools.  Voltage monitoring ServerView monitors the voltage. In an environment where ServerView is not applied, voltage irregularities cannot be detected during operation. In order to detect the problem, the server must reboot to run the BIOS Setup Utility or the Server Management Tools. As leaving the voltage surges, the server may malfunction or data loss may occur.  Power supply monitoring ServerView monitors the power supply. In an environment where ServerView is not applied, power supply irregularities cannot be detected during operation. In order to detect the problem, the server must reboot to run the BIOS Setup Utility or the Server Management Tools. System stops due to power supply failures cannot be prevented. 6.2.1 Installing ServerView  When installed using ServerStart If the OS is installed using ServerStart, ServerView will be installed at once with the OS and other high reliability tools.  When installed manually (Linux) ServerView cannot be installed using ServerStart. To install ServerView manually into a Linux system, refer to "Installation" in "ServerView User’s Guide".  Be sure to install SNMP service before installing ServerView.  When an error screen appears after ServerView installation (Windows Server 2003 only) If Windows Server 2003 Service Pack 1 is applied, the following message may appear on restarting after installing/uninstalling ServerView. In order to protect the computer, this program is terminated by Windows. Name: SNMP Service There is no problem with operations. Click [Close Message] to close the message. 166 PRIMERGY BX620 S4 Server Blade User’s Guide 6.2.2 Setting Required after Installation Perform necessary operations after ServerView installation referring to "2.4 Checking after Installation" in "ServerView User’s Guide".  Boot monitoring setting We recommend enabling the "Boot Monitoring" function after ServerView is installed. For setting procedures and explanation on the function, refer to "[Restart Settings] Tab" of "3.4 Serious Error Handling (ASR)" in "ServerView User’s Guide". 167 Chapter 6 High Reliability Tools 6.3 Maintenance Support Tool [HRM/server] HRM/server is software that supports quick and proper maintenance work to ensure stable system operation. 6.3.1 Installing HRM/server  When installed using ServerStart If the OS is installed using ServerStart, HRM/server will be installed at once with the OS and other high reliability tools.  When installed manually (Linux) HRM/server cannot be installed using ServerStart. To install HRM/server manually into a Linux system, refer to "HRM/server for PRIMERGY (Windows/ Linux)" at the following location of the PRIMERGY Startup Disc. [CD/DVD drive]: \PROGRAMS\Japanese2\HRM\iasv_hrm_install.pdf  It is necessary to install ServerView to use HRM/server. 6.3.2 How to use For system requirements for HRM/server or usage information, refer to "HRM/server for PRIMERGY (Windows/Linux)" at the following location of the PRIMERGY Startup Disc. [CD/DVD drive]: \PROGRAMS\Japanese2\HRM\iasv_hrm_install.pdf 168 PRIMERGY BX620 S4 Server Blade User’s Guide 6.4 Solving Problems Early [DSNAP] DSNAP is a tool for collectively acquiring failure investigation information such as server environment information. OS installation using ServerStart  If the OS is installed using ServerStart, DSNAP is installed with the OS and other high reliability tools. 6.4.1 Installing DSNAP Copy the following file stored in the PRIMERGY Startup Disc into the server's hard disk. • For Windows Server 2008 (64-bit) [CD/DVD drive]: \PROGRAMS\Japanese\DSNAPx64\DSNAP.EXE • For Windows Server 2008 (32-bit) [CD/DVD drive]: \PROGRAMS\Japanese\DSNAP\x86\DSNAP.EXE • For Windows Server 2003 x64 [CD/DVD drive]: \PROGRAMS\Japanese\DSNAPx64\DSNAPx64.EXE • For Windows Server 2003 [CD/DVD drive]: \PROGRAMS\Japanese\DSNAP\DSNAP.EXE 6.4.2 How to Use Refer to the following file stored in the PRIMERGY Startup Disc. Use a text editor to open it. • For Windows Server 2008 [CD/DVD drive]: \PROGRAMS\Japanese\DSNAP\README_JP.TXT • For Windows Server 2003 x64 [CD/DVD drive]: \PROGRAMS\Japanese\DSNAPx64\README_JP.TXT • For Windows Server 2003 [CD/DVD drive]: \PROGRAMS\Japanese\DSNAP\README_JP.TXT 169 Chapter 6 High Reliability Tools 170 Chapter 7 Installing Internal Options This chapter explains how to install internal options on this Server Blade. 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 Before Installing Internal Options . . . . . . . . . . . . . . . . . . . Removing and Attaching the Top Cover . . . . . . . . . . . . . . Installing a CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing Memory Modules . . . . . . . . . . . . . . . . . . . . . . . Installing an Expansion Card . . . . . . . . . . . . . . . . . . . . . . Installing an Expansion Board . . . . . . . . . . . . . . . . . . . . . Installing an Internal Hard Disk Unit . . . . . . . . . . . . . . . . . BIOS Setting with Expansion Card Installed . . . . . . . . . . . Connection Examples of an External Option Device . . . . . 172 174 176 182 188 194 197 201 202 171 Chapter 7 Installing Internal Options 7.1 Before Installing Internal Options The following types of internal options can be installed on this Server Blade. Expansion board Memory modules CPU Expansion card slot module Internal hard disk units • When installing or removing internal options, make sure to remove the Server Blade from the Chassis. Failure to do so may cause electric shock. For details on how to remove the Server Blade from the Chassis, refer to "BX600 S3 Blade Server System Unit Hardware Guide". • Do not install unauthorized third party internal options. Doing so may cause a device failure, fire, or electric shock. • Do not damage or modify internal cables or devices. Doing so may cause a device failure, fire, or electric shock. 172 PRIMERGY BX620 S4 Server Blade User’s Guide • The internal components such as the radiation fin remain hot just after the Server Blade was removed from the Chassis. When installing or removing internal options, turn the Server Blade off, and wait for a while to begin operations. In the array system configuration (RAID1), you can replace the internal hard disk unit without turning the power off. • The circuit boards and soldered parts of internal options are exposed. They can be damaged by static electricity. Before handling them, first touch a metal part of the Chassis to discharge static electricity. • Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. • If devices are installed using the methods other than those outlined in this chapter or disassembled, the warranty will be invalidated.  When installing or removing devices, make sure to use the removed screws on the same location and devices that were last installed or removed. Failure to do so may damage the device.  The types of installable options described in this manual are subject to change without notice.  For secure use of PRIMERGY, use the product shown in the system configuration diagram when installing optional products (such as internal/external optionals and USB devices etc). Note that FUJITSU does not guarantee any server operations if any third party optional devices are used. 173 Chapter 7 Installing Internal Options 7.2 Removing and Attaching the Top Cover This section explains how to remove and attach the top cover. • When installing or removing the top cover, make sure to remove the Server Blade from the Chassis. Failure to do so may cause electric shock. For details on how to remove the Server Blade from the Chassis, refer to "BX600 S3 Blade Server System Unit Hardware Guide". • Use tip preventive stabilizers when installing the rack. Pulling the Server Blade out of the rack without installing stabilizers may cause the rack to tip over. 7.2.1 How to Remove the Top Cover 1 Turn off the server. →"3.3 Turning Off the Server" in "BX600 S3 Blade Server System Unit Hardware Guide" 2 Touch a metal part of the Chassis to discharge static electricity. 3 Remove the target Server Blade from the Chassis. →"4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide" 4 While pressing the buttons, slide the top cover a little backward, and carefully pull it up. Buttons 174 PRIMERGY BX620 S4 Server Blade User’s Guide  How to attach the top cover To attach the top cover, simply reverse the removal procedures.  Make sure that no tools or unnecessary components were left inside the Server Blade before attaching the top cover back into place.  Before turning on the Server Blade, make sure that the top cover is attached. 175 Chapter 7 Installing Internal Options 7.3 Installing a CPU This Server Blade can have up to two CPUs by adding an optional CPU. • When installing or removing the CPU, make sure to remove the Server Blade from the Chassis. Failure to do so may cause electric shock. For details on how to remove the Server Blade from the Chassis, refer to "BX600 S3 Blade Server System Unit Hardware Guide". • Do not install unauthorized third party CPUs. Doing so may cause failures. • Do not use CPUs that differ in frequency/cache capacity. An error message appears on the BIOS screen. • The circuit boards and soldered parts of internal options are exposed. They can be damaged by static electricity. Before handling them, first touch a metal part of the Chassis to discharge static electricity. • Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. 7.3.1 Location of CPU Installation CPU socket 1 is installed with a CPU as standard. CPUs must be installed in the order of the socket numbers. [Front] [Rear] Baseboard CPU socket 2 (optional) CPU socket 1 (standard) 176 PRIMERGY BX620 S4 Server Blade User’s Guide 7.3.2 Available CPUs and Notes  Available CPUs The following optional CPU types can be used for this Server Blade. As the additional CPU(s), install CPUs of the same model. table: List of Available CPUs Product name Model Remarks Processor Xeon E5205 (1.86GHz/6MB) PG-FG43G Processor Xeon X5260 (3.33GHz/6MB) 1.86GHz/6MB, Dual core PG-FG43H 3.33GHz/6MB, Dual core Processor Xeon E5405 (2GHz/12MB) PG-FG43J 2GHz/12MB, Quad core Processor Xeon E5420 (2.5GHz/12MB) PG-FG43K 2.5GHz/12MB, Quad core Processor Xeon X5460 (3.16GHz/12MB) PG-FG43L 3.16GHz/12MB, Quad core Processor Xeon L5410 (2.33GHz/12MB) PG-FG43P 2.33GHz/12MB, Quad core Packaged items of the optional CPU  Before installing a CPU, refer to "Appendix B.1 CPU Specifications" (pg.264) to check the contents of the optional package. 177 Chapter 7 Installing Internal Options 7.3.3 How to Install a CPU 1 Turn off the Server Blade. → "3.3 Turning Off the Server" in "BX600 S3 Blade Server System Unit Hardware Guide" 2 Touch a metal part of the Chassis to discharge static electricity. 3 Remove the Server Blade from the Chassis to install a CPU. → "4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide" 4 Remove the top cover. "7.2 Removing and Attaching the Top Cover" (pg.174) 5 Remove the dummy CPU cover. Loosen the screws Dummy CPU cover 6 Pull up the tab of the CPU slot cover to remove the cover. Tab CPU slot cover 178 PRIMERGY BX620 S4 Server Blade User’s Guide 7 Release the socket lever and the CPU fastener. 1. Unhook the socket lever, and pull it up carefully. 2. Press the CPU fastener tab with an index finger to open the CPU fastener. Be careful not to touch the CPU socket pin, etc. (1) After pulling up the CPU fastener, open it from this part being careful not to touch other parts. Socket lever CPU fastener Tab (2) • When opening the CPU fastener, be careful not to bend any pins in the CPU socket. Doing so may cause failures. 8 Install the CPU. 1. Remove the cover attached to the CPU. 2. Check the marking (small triangle) on the CPU and on the CPU socket. 3. Hold the parts shown in ellipses on the CPU in the following figure, and align the markings and carefully insert the CPU. Marking Hold these parts • Do not touch the CPU electrode. Doing so may cause a failure. • When installing the CPU in the socket, be careful not to bend any pins in the CPU socket. 179 Chapter 7 Installing Internal Options 9 Return the CPU fastener and the socket lever to their original positions, and fasten the CPU. 1. Close the CPU fastener. 2. Close the socket lever to fasten the CPU. Socket lever (2) (1) CPU fastener 10 Attach the heat sink. Remove the grease cover on the back before attaching the heat sink. Tighten screws Tighten screws Heat sink  Carefully tighten the heat sink screws in a cross pattern. 11 Attach the top cover. "7.2 Removing and Attaching the Top Cover" (pg.174) 12 Install the Server Blade to the Chassis. → "4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide" 13 Turn on the Server Blade and check the BIOS Setup Utility settings. Start the BIOS Setup Utility and select the [Server] menu – the [CPU Status] submenu to check that [CPUn Status] (n: slot number) is set to [Enabled]. If the CPU is set to [Disabled], change the setting to [Enabled]. For more details, refer to "8.2.8 Server Menu" (pg.216). 180 PRIMERGY BX620 S4 Server Blade User’s Guide  How to remove a CPU To remove a CPU, simply reverse the installation procedures. 7.3.4 Defective CPU Disconnection Function This server is equipped with the defective CPU disconnection function. This function disconnects the CPU judged to be defective (abnormal) during Power On Self Test (POST) to start the server. On two CPU servers, if one CPU is defective, the other CPU starts up the server. The failed CPU can be checked using the information displayed during POST or from [CPUn Status] (n: slot number) in the [CPU Status] submenu of the [Server] menu in the BIOS Setup Utility ("8.2.10 CPU Status Submenu" (pg.220)).  Removing the defective CPU 1 Turn on the server and check the location of the defective CPU by the message displayed during POST. 2 Replace the defective CPU with a new CPU according to "7.3.3 How to Install a CPU" (pg.178). 3 Turn on the server and start the BIOS Setup Utility. "8.2.1 Starting and Exiting the BIOS Setup Utility" (pg.205) 4 Select [CPU Status] on the Server menu and check that the item corresponding to the replaced CPU is set to [Enabled]. If it is set to [Failed] or [Disabled], change the status to [Enabled]. "8.2.10 CPU Status Submenu" (pg.220)  If the setting is not changed to [Enabled], the server will start with the new CPU still marked as defective and always disconnected. By changing the setting to [Enabled], the defective CPU status is cancelled and the new CPU can be used at the next start of the server. 181 Chapter 7 Installing Internal Options 7.4 Installing Memory Modules Additional memory will help to increase the amount of data to read at a time and improve the server processing capability. • When installing or removing the memory modules, make sure to remove the Server Blade from the Chassis. Failure to do so may cause electric shock. For details on how to remove the Server Blade from the Chassis, refer to "BX600 S3 Blade Server System Unit Hardware Guide". • Do not install unauthorized third party memory modules. Doing so may cause electric shock, a fire, or failures. • Wait for a sufficient period of time after server shutdown before installing or removing memory. Failure to do so may cause burns. • When installing or removing memory modules, make sure to remove the screws on the specified points only. There is chance of injury if screws other than those on the specified points are removed. It may also damage the server. • Touch only the specified part of the printed circuit board. Failure to do so may cause injury. It may also damage the server. • The circuit boards and soldered parts of internal options are exposed. They can be damaged by static electricity. Before handling them, first touch a metal part of the Chassis to discharge static electricity. • Do not insert and remove memory modules repeatedly. Doing so may cause failures. • Hold the edge of the memory module as shown below. Do not touch the part with gold wire (terminal) or memory chip. Do not touch this part. Memory module Memory chip 182 PRIMERGY BX620 S4 Server Blade User’s Guide 7.4.1 Location of Memory Module Installation Install memory modules to the memory slots in the Server Blade. Each memory bank consists of slot 1/2, 3/4, 5/6, and 7/8 on this Server Blade. To add more memory, install memory modules in pairs, each having the same capacity, to the corresponding slots in the sequence of Bank 1, Bank 2, Bank 3, and Bank 4, in ascending order of their capacity. Memory bank 1 has memory modules as the standard. [Front] [Rear] Baseboard Memory bank 1 Memory bank 3 Memory bank 2 Memory bank 4 Memory Slot 1 (Standard) Memory Slot 5 (Optional) Memory Slot 2 (Standard) Memory Slot 6 (Optional) Memory Slot 3 (Optional) Memory Slot 7 (Optional) Memory Slot 4 (Optional) Memory Slot 8 (Optional) 7.4.2 Available Memory Modules and Notes  Available memory modules Memory of this Server Blade consists of two the Dual In-Line Memory Modules (DIMM) in pairs and memory modules are extended in pairs. The following memory module types can be used on this Server Blade. table: List of Available Memory Modules Product name Model Remarks Memory Module-1GB PG-RM1CJ 512MB-DDR2 DIMM ×2 Memory Module-2GB PG-RM2CJ 1GB-DDR2 DIMM ×2 Memory Module-4GB PG-RM4CJ 2GB-DDR2 DIMM ×2 Memory Module-8GB PG-RM8CJ 4GB-DDR2 DIMM ×2 Packaged items of optional memory  Before installing memory modules, refer to "Appendix B.2 Memory Specifications" (pg.265) to check the contents of the optional package. 183 Chapter 7 Installing Internal Options  Notes on installing memory modules  Identifying memory modules Make sure to install a pair of DIMMs, each having the same capacity. Check that the number beginning with "CA" (e.g., CA05946-E101) printed on the label is same on the two DIMMs. Be sure to use a pair of modules with the same number. If the DIMMs have identification labels, be sure to install a pair of DIMMs with the same capacity with the label placed on the same location. • Identification label location Identification label B Identification label A Identification label C • Identification label patterns When a memory module is viewed with the corner circled in the above figure to the lower left, identification labels are applied in any of the following patterns. table: Identification Label Patterns 184 Pattern Label A Label B Label C 1 Not applied Not applied Not applied 2 Applied Not applied Not applied 3 Not applied Applied Not applied 4 Not applied Not applied Applied 5 Applied Applied Not applied 6 Applied Not applied Applied 7 Not applied Applied Applied 8 Applied Applied Applied PRIMERGY BX620 S4 Server Blade User’s Guide  Memory redundancy function The memory redundancy function (memory mirroring function) can be set for this Server Blade. When the memory redundancy function is enabled, a mirrored set containing two identical memory banks is configured. When data is saved, it is written to both memory banks. This means that the available memory capacity (logical capacity) is half that of the physical capacity during memory redundancy. When a memory error occurs, the memory bank in which the error occurred will be automatically disconnected, and the other memory bank will take over operations. After replacing the failed memory or the failed memory bank, the mirrored set is automatically restored.  Installation conditions Install the memory module according to the following conditions. table: Conditions when using the memory mirroring function Mirror set #1 Bank 1 Mirror set #2 Bank 2 Bank 3 Bank 4 Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 I I I I − − − − I I I I I I I Ι I: Install memory module. -: Do not install memory module.  Install memory modules of the same model to the four slots that make up one mirror set.  The capacity of two mirror sets can be different.  BIOS settings After installing the memory module, perform the following settings. 1 Start the BIOS Setup Utility. "8.2.1 Starting and Exiting the BIOS Setup Utility" (pg.205) 2 From the [Server] menu - the [Memory Status] submenu, change the [Memory Mirror] setting to [Mirror]. "8.2.11 Memory Status Submenu" (pg.221) 3 Save the setting and exit the BIOS Setup Utility. "8.2.11 Memory Status Submenu" (pg.221) 185 Chapter 7 Installing Internal Options 7.4.3 How to Install/Remove Memory Module This section explains how to install and remove memory modules. 1 Turn off the Server Blade. → "3.3 Turning Off the Server" in "BX600 S3 Blade Server System Unit Hardware Guide" 2 Touch a metal part of the Chassis to discharge static electricity. 3 Remove the Server Blade from the Chassis to install a memory module. → "4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide" 4 Remove the top cover. "7.2 Removing and Attaching the Top Cover" (pg.174) 5 Install or remove memory modules. When installing Insert a memory module properly into the memory slot. The levers close. If the levers are not closed completely, push them with your fingers. Align notch Lever When removing Open the levers on both ends. • Make sure not to open the clips outward too quickly because the memory module may pop up, which could cause damage. 6 Check that the memory module is inserted all the way. • An improperly engaged memory module could cause a fire. Do not insert the memory module on the wrong side. 7 Attach the top cover. "7.2 Removing and Attaching the Top Cover" (pg.174) 186 PRIMERGY BX620 S4 Server Blade User’s Guide 8 Install the Server Blade to the Chassis. → "4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide" 7.4.4 Defective Memory Disconnection Function This Server Blade is equipped with the defective memory (RAM module) disconnection function. This function disconnects memory blocks (two DIMMs) judged to be defective (abnormal) during Power On Self Test (POST) to start the Server Blade. When POST is executed, if the memory capacity is discovered to be smaller than the capacity of the memory installed, there is a possibility of memory defect. From POST error messages or the system event log, you can check the slot location that has defective memory. "9.2.2 Error Messages" (pg.234) "9.3 System Event Log" (pg.243) If defective memory is discovered, replace it, and then restart the Server Blade.  Replacing the defective memory Replace the defective memory with a new one according to "7.4.3 How to Install/Remove Memory Module" (pg.186).  After replacing the memory module, start the BIOS Setup Utility and select the [Server] menu - the [Memory Status] submenu to check that [DIMM n,n] (n is the number of the replaced memory module) for the replaced memory module is set to [Enabled]. If the item is set to [Disabled], change the setting to [Enabled]. If it is not set to [Enabled], the server will start with the memory module recognized as being defective and constantly disconnected. To use a new memory module, set the item to [Enabled] for releasing the failed memory status at the next startup. "8.2.11 Memory Status Submenu" (pg.221) 187 Chapter 7 Installing Internal Options 7.5 Installing an Expansion Card This Server Blade can be equipped with one expansion card using the expansion card slot module. This section explains the types of expansion card, installation procedures, and notes on expansion cards. • When installing or removing an expansion card, make sure to remove the Server Blade from the Chassis. Failure to do so may cause electric shock. For details on how to remove the Server Blade from the Chassis, refer to "BX600 S3 Blade Server System Unit Hardware Guide". • The circuit boards and soldered parts of internal options are exposed. They can be damaged by static electricity. Before handling them, first touch a metal part of the Chassis to discharge static electricity. • Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. • Expansion cards are susceptible to static electricity. Place them on conductive pads or keep them in their packaging as long as they are not necessary. 7.5.1 Location of Expansion Card Installation Insert an expansion card in a PCI slot of the expansion card slot module, and then install the slot module in the expansion card slot of the Server Blade. [Server Blade (Front view)] Expansion card slot [Expansion card slot module] PCI slot 188 PRIMERGY BX620 S4 Server Blade User’s Guide 7.5.2 Available Expansion Card Slot Modules/Expansion Cards and Notes  Available expansion card slot modules table: Available expansion card slot module Product name Model Remarks Expansion Card Slot Module PG-CS103 64bit 133MHz, PCI-X Expansion Card Slot Module PG-CS104 PCI-Express (x4)  Available expansion cards and installable expansion card slot modules table: List of available expansion cards and corresponding slot modules Product name (model) Expansion card slot module Remarks PG-CS103 PG-CS104 SCSI Ctrl U160 lp (PG-1301L) Ι − PCI-X, Ultra160 SCSI, For connection with external backup devices Eth. Ctrl 2 x 1Gbit PCI-E 1000BASE-T lp (PG-2861L) − Ι PCI-Express, 1000BASE-T, Dual Port SAS RAID Ctrl (PG-248EL) − Ι PCI-Express, For connection with Storage Blade I: Installable -: Not installable  For the latest information of the expansion card supported in this Server Blade, refer to Recommendation Options in the Fujitsu PRIMERGY website (http://primergy.fujitsu.com).  Notes on installing expansion cards  Drivers For details on each expansion card driver, refer to "2.3.5 Onboard Controller and Expansion Cards Supported by ServerStart" (pg.45).  Notes on each card Before installing an expansion card, refer to the notes in the expansion card manual.  SCSI card • Connection of a SCSI device Connect the SCSI device supported by this server to the SCSI card. Operations of unsupported SCSI devices are not guaranteed. 189 Chapter 7 Installing Internal Options  Notes when adding an Expansion Card Slot Module When using an onboard array controller in this Server Blade and replacing the SAS module that is installed standardly with an Expansion Card Slot Module (PG-CS103/PG-CS104), initialization of the logical drive of the array controller may be performed after replacing the module. This is due to the fact that information about data consistency, which is used to record whether write data is correctly written to the internal hard disk unit in the past, is stored on the standard SAS module. When the information is lost by replacing the module, initialization is automatically executed to ensure data consistency. For details about initialization, refer to the manual in the Array controller Document & Tool CD. 7.5.3 How to Install an Expansion Card To install the PCI-X and PCI-Express cards, perform the same procedures. 1 Turn off the Server Blade. → "3.3 Turning Off the Server" in "BX600 S3 Blade Server System Unit Hardware Guide" 2 Touch the metal part of the Chassis to discharge static electricity. 3 Remove the Server Blade to install an expansion card slot module in, from the Chassis. → "4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide" 4 Remove the top cover. "7.2 Removing and Attaching the Top Cover" (pg.174) 5 Remove the standard SAS module from the Server Blade. Remove the screw, and remove the standard SAS module. SAS module Screw 190 PRIMERGY BX620 S4 Server Blade User’s Guide 6 Remove the slot cover of the expansion card slot module. Remove the screw, and remove the slot cover. Slot cover Screw  Make sure to keep the removed slot cover for later use. 7 Install the expansion card to the expansion card slot module. 1. Securely insert the expansion card in the PCI slot. Insert the expansion card with its circuitry side facing downwards. 2. Secure the expansion card using the screw. Secure the expansion card using the screw removed in step 6. PCI slot (1) (2) Screw 191 Chapter 7 Installing Internal Options 8 Install the expansion card slot module in the Server Blade. Insert the expansion card slot module in the connector for the expansion card slot module and close the cover to make sure that it is fully inserted. Expansion card slot module connector Cover 9 Secure the expansion card slot module. Secure the module using the screw removed in Step 5. Screw 10 Attach the top cover. "7.2 Removing and Attaching the Top Cover" (pg.174) 11 Install the Server Blade in the Chassis. → "4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide" 12 Turn on the Server Blade and check the BIOS Setup Utility settings. Referring to "7.8 BIOS Setting with Expansion Card Installed" (pg.201), confirm whether the setting satisfies card installation conditions. If the setting does not satisfy those installation conditions, change the setting. 192 PRIMERGY BX620 S4 Server Blade User’s Guide  How to remove an expansion card To remove the expansion card, simply reverse the installation procedures. 193 Chapter 7 Installing Internal Options 7.6 Installing an Expansion Board One expansion board can be installed in this Server Blade. When the expansion board is installed, you can connect to external devices, etc. through the Network Blade. • When installing or removing an expansion board, make sure to remove the Server Blade from the Chassis. Failure to do so may cause electric shock. For details on how to remove the Server Blade from the Chassis, refer to "BX600 S3 Blade Server System Unit Hardware Guide". • The circuit boards and soldered parts of internal options are exposed. They can be damaged by static electricity. Before handling them, first touch a metal part of the Chassis to discharge static electricity. • Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. • Expansion boards are susceptible to static electricity. Place them on conductive pads or keep them in their packaging as long as they are not necessary. 7.6.1 Location of Expansion Board Installation Install the expansion board in the expansion board slot in the Server Blade. Expansion board slot 194 PRIMERGY BX620 S4 Server Blade User’s Guide 7.6.2 Available Expansion Boards The table below lists the expansion boards available on this Server Blade. table: Available Expansion Boards Product name Model 4Gbit/s FC I/O Module PG-FCD201 2Gbit/s FC I/O Module PG-FCD102 (*1) 1Gbit/s Ethernet I/O Module PG-LND201 *1: If installing this expansion board, it cannot be installed in a BX600 S3 Chassis. 7.6.3 How to Install an Expansion Board 1 Turn off the Server Blade. → "3.3 Turning Off the Server" in "BX600 S3 Blade Server System Unit Hardware Guide" 2 Touch a metal part of the Chassis to discharge static electricity. 3 Remove the Server Blade from the Chassis to install an expansion board. → "4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide" 4 Remove the top cover. "7.2 Removing and Attaching the Top Cover" (pg.174) 5 Install the expansion board. Check that the expansion board is securely inserted to the slot. [Rear] Expansion board Expansion board slot 195 Chapter 7 Installing Internal Options 6 Fix the expansion board using the screws supplied with the board. Screws 7 Attach the top cover. "7.2 Removing and Attaching the Top Cover" (pg.174) 8 Install the Server Blade to the Chassis. → "4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide"  To connect the expansion board to a fibre channel device, install the Fibre Channel expansion board in the Server Blade and the FC Network Blade in the Chassis, then install the SFP module (option) in the FC Network Blade. For details, refer to "BX600 S3 Blade Server System Unit Hardware Guide". 9 Turn on the Server Blade and check the BIOS Setup Utility settings. Referring to "7.8 BIOS Setting with Expansion Card Installed" (pg.201), confirm whether the setting satisfies card installation conditions. If the setting does not satisfy those installation conditions, change the setting.  How to remove an expansion board To remove an expansion board, simply reverse the installation procedures. 196 PRIMERGY BX620 S4 Server Blade User’s Guide 7.7 Installing an Internal Hard Disk Unit This section explains how to install internal hard disk units. • When installing or removing the units, make sure to remove the Server Blade from the Chassis. Failure to do so may cause electric shock. For details on how to remove the Server Blade from the Chassis, refer to "BX600 S3 Blade Server System Unit Hardware Guide". In the array system configuration (RAID1), you can replace the internal hard disk unit without turning the power off. • Rough handling of the hard disk unit can damage the stored data. To cope with any unexpected problems, always back up important data. When backing up data to another hard disk unit, you should make backups on a file or block basis. • Use the unit in a dry place with low airborne dust levels. • Use the device on a shock-and-vibration free surface. • Keep the device away from direct sunlight, radiators or other heat sources. • Do not use the unit in a place where the temperature is extremely high or low, or experiences extreme temperature changes. • Do not disassemble the hard disk unit. • Take great care so that you do not hit the hard disk or bring it into contact with metallic objects. • The circuit boards and soldered parts of internal options are exposed. They can be damaged by static electricity. Before handling them, first touch a metal part of the Chassis to discharge static electricity. • Do not touch the circuitry on boards or soldered parts. Hold the metallic areas or the edges of the circuit boards. 197 Chapter 7 Installing Internal Options 7.7.1 Location of Internal Hard Disk Units Installation Install the internal hard disk unit in the order of bay numbers (1 – 2). [Server Blade (Front view)] 2.5-inch storage bay 2 2.5-inch storage bay 1 7.7.2 Available Internal Hard Disk Units and Notes  Available internal hard disk units The following internal hard disk units can be installed in this Server Blade. table: Available Internal Hard Disk Units Product name Model Overview HDD SAS 10k 73GB hot plug 2.5inch PG-HDD71B 73.4GB, 10,025rpm, SAS 2.5inch, hot-pluggable HDD SAS 15k 73GB hot plug 2.5inch PG-HDD75B 73.4GB, 15,000rpm, SAS 2.5inch, hot-pluggable HDD SAS 10k 147GB hot plug 2.5inch PG-HDD41B 146.8GB, 10,025rpm, SAS 2.5inch, hot-pluggable Package items of optional internal hard disk unit  Before installing the internal hard disk unit, refer to "Appendix B.3 Internal Hard Disk Unit Specifications" (pg.265) to check the contents of the optional package.  Notes on using the onboard array controller When manually installing the OS, the array must be configured under the onboard array controller before installation. To enable the RAID1 array configuration, the array must be initialized after its configuration is completed. For more details on how to create the array configuration and initialize the array, refer to the manual in the Array controller Document & Tool CD. 198 PRIMERGY BX620 S4 Server Blade User’s Guide 7.7.3 How to Install the Internal Hard Disk Unit 1 Turn off the Server Blade. → "3.3 Turning Off the Server" in "BX600 S3 Blade Server System Unit Hardware Guide" 2 Touch a metal part of the Chassis to discharge static electricity. 3 Remove the dummy unit from the bay to accommodate an internal hard disk unit. A dummy unit is inserted into a bay not occupied by an internal hard disk unit. Pull the dummy unit out towards you with its tabs being pressed inward. Be sure to keep the removed dummy units for later use. Tabs 4 Install the internal hard disk unit into the Server Blade. 1. Fully insert the internal hard disk unit in the bay while the cover of the internal hard disk unit is open. 2. Close the cover of the internal hard disk unit securely, and lock the tab. (2) (1) Cover Tab 199 Chapter 7 Installing Internal Options  How to remove the internal hard disk unit 1 Turn off the Server Blade. → "3.3 Turning Off the Server" in "BX600 S3 Blade Server System Unit Hardware Guide" 2 Touch a metal part of the Chassis to discharge static electricity. 3 Remove the internal hard disk unit. While pressing the tab, open the cover, and pull out the internal hard disk unit. To remove the internal hard disk unit, use both hands to pull it out. (1) (2) Cover Tab 4 Install a new internal hard disk unit or a dummy unit. "7.7.3 How to Install the Internal Hard Disk Unit" (pg.199)  Replacing the failed internal hard disk unit When RAID (RAID1) is configured with this server, a failed hard disk unit can be replaced and the restoration can be performed without turning off the server and peripheral devices (hot swappable/hot pluggable). For more details on the replacement procedure, refer to the manual in the Array controller Document & Tool CD. For more details on the RAID, also refer to the manual in the Array controller Document & Tool CD. 200 PRIMERGY BX620 S4 Server Blade User’s Guide 7.8 BIOS Setting with Expansion Card Installed In this Server Blade, the settings of the BIOS Setup Utility must be changed according to installation conditions when installing the following expansion boards or cards. • 4Gbit/s FC I/O Module (PGFCD201) • 2Gbit/s FC I/O Module (PG-FCD102) • 1Gbit/s Ethernet I/O Module (PG-LND201) • Eth. Ctrl 2 x 1Gbit PCI-E 1000-BASE-T lp (PG-2861L) • SCSI Ctrl U160 lp (PG-1301L) • SAS RAID Ctrl (PG-248EL) For a device that starts the OS, use the BIOS Setup Utility to set the optional ROM (OPROM) to [Enabled]. For more details on the setting procedures, refer to "8.2.5 PCI Configuration Submenu" (pg.212) in the [Advanced] menu.  Refer to the "PRIMERGY BX620 S2 Server Blade User's Guide" or "PRIMERGY BX620 S3 Server Blade User's Guide" when performing 2Gbit/s FC I/O Module (PG-FCD102) settings. 201 Chapter 7 Installing Internal Options 7.9 Connection Examples of an External Option Device This section explains the connection modes of external optional devices. 7.9.1 Connection of a Backup Cabinet Connect the backup cabinet to the SCSI card installed in the expansion card slot module. The following shows a connection example: Internal hard disk units Chassis [Front] Mid-plane Baseboard PRIMERGY SX10 Backup cabinet (PG-R1BC4) Server Blade SCSI Cable (PG-CBLS001 / PG-CBLS002 : Sold separately) SCSI Ctrl U160 lp (PG-1301L) Expansion Card Slot Module (PCI-X) (PG-CS103) 7.9.2 Connection of Storage Blade Connect the Storage Blade to the SAS RAID Ctrl installed in the expansion car slot module. The following shows a connection example: Chassis [Front] Midplane Baseboard SAS RAID Ctrl (PG-248EL) Expansion Card Slot Module (PG-CS104) Server Blade PRIMERGY SX650 Storage Blade (PG-B6ADC1) 202 SAS cable (provided with PRIMERGY SX650 Storage Blade) Chapter 8 Hardware Configuration/ Utilities This chapter explains how to make the environment settings necessary to operate the Server Blade. 8.1 Switch Block Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 8.2 BIOS Setup Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 203 Chapter 8 Hardware Configuration/Utilities 8.1 Switch Block Settings This section explains how to set the switch block. • When setting the switch block, be sure to turn the Server Blade off, and then remove the Server Blade from the Chassis. Failure to do so may cause electric shock. For details on how to remove the Server Blade from the Chassis, refer to "BX600 S3 Blade Server System Unit Hardware Guide". 8.1.1 Switch Block This section explains how to set the switch block ("b" in "1.3.3 Baseboard" (pg.31)) on the baseboard. ON OFF 1 2 3 4 5 6 The following table shows the description of each switch. table: Switch Block Settings Switch No. 204 Description Switch 1 Sets whether or not to delete a password. • ON: Deletes the password. • OFF: Does not delete the password. (Default) Switch 2 Sets whether or not to clear the information stored on the CMOS. • ON: Clears the information stored on the CMOS. • OFF: Maintains the information stored on the CMOS. (Default) Switch 3 Always keep in OFF position. Switch 4 Always keep in OFF position. Switch 5 Always keep in ON position. Switch 6 Always keep in ON position. PRIMERGY BX620 S4 Server Blade User’s Guide 8.2 BIOS Setup Utility This section explains settings for the BIOS Setup Utility and items regarding each setting. 8.2.1 Starting and Exiting the BIOS Setup Utility The following explains how to start and exit the BIOS Setup Utility.  How to start the BIOS Setup Utility 1 Turn on the main power of the Chassis. → "3.2 Turning On the Server" in "BX600 S3 Blade Server System Unit Hardware Guide" 2 Turn the Server Blade on. → "3.2 Turning On the Server" in "BX600 S3 Blade Server System Unit Hardware Guide" 3 After the memory capacity is displayed, if "Press F2 to run Setup Press F12 for BBS POPUP" appears on the screen, press the [F2] key. The [Main] menu appears. BIOS SETUP UTILITY Main Advanced Security Server Boot System Overview Exit Use [ENTER],[TAB] or [SHIFT-TAB] to select a field. AMIBIOS Version Build Date BIOS Version BMC F/W Version 08.00.12 mm/dd/yy nnnn nnnn System Time System Date [hh:mm:ss] [xxx mm/dd/yyyy] Sync RTC with Mgmt. Blade [Enabled] System Memory Size 3072MB Use [+] or [-] to configure system Time. +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. 205 Chapter 8 Hardware Configuration/Utilities  Key operations with the BIOS Setup Utility The roles of the keys used for setting the BIOS Setup Utility are as follows: table: List of Key Operations on the BIOS Setup Utility Window Key Role [F1] Displays help information. [Esc] When a submenu window is displayed, exits it and returns to the previous menu. When the menu window is displayed, displays the [Exit] menu. [←] [→] Switches between menus. [↑] [↓] Scrolls through the menu option list. [Page Up] [Page Down] Moves the cursor to the beginning or end of an item. [Enter] Selects a set item. For items displayed with , displays the submenu. When a submenu is displayed, pressing the [Esc] key returns to the menu window. [−][+] Changes the value of an item. [F2] [F3] Changes the color of the BIOS setting window. [F7] Sets the set values of all the items to the stored values. [F9] Sets all the items to the initial values. [F10] Saves the settings and exits the BIOS Setup Utility.  How to exit the BIOS Setup Utility 1 Use the [←] [→] keys to display the [Exit] menu. BIOS SETUP UTILITY Main Advanced Security Exit Options Save Changes and Exit Discard Changes and Exit Load Previous Value Server Boot Exit Exit system setup after saving the changes. F10 key can be used for this operation. Get Default Values +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. 206 PRIMERGY BX620 S4 Server Blade User’s Guide 2 Use the [↑] [↓] keys to select the exit mode. To save configuration changes before exiting: Move the cursor to [Save Changes and Exit] and press the [Enter] key. The message "Save configuration changes and exit setup?" is displayed. To exit without saving configuration changes: Move the cursor to [Discard Changes and Exit] and press the [Enter] key. The message "Discard changes and exit setup?" is displayed. 3 Use the [←] [→] keys to move the cursor to [OK] or [Cancel], and press the [Enter] key. When selected [Save Changes and Exit]: Select [OK] to exit. After saving changes to settings, the BIOS Setup Utility closes and the server restarts. To return to the BIOS Setup Utility without exiting this program, select [Cancel]. When selected [Discard Changes and Exit]: Select [OK] to exit without saving the settings. The BIOS Setup Utility closes and the OS starts. To return to the BIOS Setup Utility without exiting this program, select [Cancel]. 207 Chapter 8 Hardware Configuration/Utilities 8.2.2 Main Menu The [Main] menu window is initially displayed when you start the BIOS Setup Utility. Settings for time and date and for the drives are configured in the [Main] menu window. BIOS SETUP UTILITY Main Advanced Security Server Boot System Overview Exit Use [ENTER],[TAB] or [SHIFT-TAB] to select a field. AMIBIOS Version Build Date BIOS Version BMC F/W Version 08.00.12 mm/dd/yy nnnn nnnn System Time System Date [hh:mm:ss] [xxx mm/dd/yyyy] Sync RTC with Mgmt. Blade [Enabled] System Memory Size 3072MB Use [+] or [-] to configure system Time. +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Main Menu Item Setting Description Version - Displays the AMIBIOS version. Build Date - Displays the date that the AMIBIOS is built. BIOS Version - Displays the BIOS version of the Server Blade. BMC F/W Version - Displays the BMC firmware version of the Server Blade. System Time Present time The system time is set in "hours:minutes:seconds" format. The hours should be based on a 24-hour clock. For example, 6:30:00 P.M. is set as "18", "30", "00". This can be set when [Sync RTC with Mgmt. Blade] is set to [Disabled]. Note:  Repeat the procedure until the correct time is set.  If a highly precise system time is necessary, install a network synchronized time system (NTP, etc.). 208 System Date Present date The system date is set in "month:day:year" format. For example, April 20, 2008 is set as "04", "20", "2008". This can be set when [Sync RTC with Mgmt. Blade] is set to [Disabled]. Sync RTC with Mgmt. Blade • Disabled • Enabled (Initial value) Sets whether or not to synchronize the time between the Management Blade and RTC. System Memory Size - Displays the size of the installed memory. PRIMERGY BX620 S4 Server Blade User’s Guide 8.2.3 Advanced Menu This menu configures the server management and peripheral devices. BIOS SETUP UTILITY Main Advanced Security Server Boot Advanced Settings WARNING: Setting wrong values in below sections may cause system to malfunction. Reset Configuration Data Exit Exit Configure the MP Specification revision level. Some operating systems will require 1.1 for compatibility reasons. [No] Peripheral Configuration PCI Configuration CPU Configuration +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Advanced Menu Item Setting Description Reset Configuration Data • No (Initial value) • Yes Sets the initialization of the Extended System Configuration Data (ESCD) where the system resources are recorded. This setting is changed to [No] whenever the system is restarted. Peripheral Configuration - Configures a serial port. Press the [Enter] key to display the submenu. "8.2.4 Peripheral Configuration Submenu" (pg.210) PCI Configuration - Configures the PCI device. Press the [Enter] key to display the submenu. "8.2.5 PCI Configuration Submenu" (pg.212) CPU Configuration - Configures CPU. Press the [Enter] key to display the submenu. "8.2.6 CPU Configuration Submenu" (pg.213) 209 Chapter 8 Hardware Configuration/Utilities 8.2.4 Peripheral Configuration Submenu This submenu appears when [Peripheral Configuration] is selected from the Advanced menu. It configures a serial port. BIOS SETUP UTILITY Main Advanced Security Server Boot Exit Allows BIOS to Select Serial Port1 Base Addresses. Peripheral Configuration Serial 1 Serial Port1 Address [3F8/IRQ4] USB Configuration +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Peripheral Configuration Submenu Item Setting Serial Port1 Address • • • • • USB Configuration - Disabled 3F8/IRQ 4 (Initial value) 2F8/IRQ 3 3E8/IRQ 4 2E8/IRQ 3 Description Sets the I/O port address and IRQ level of the serial port. Configure the USB device. Press the [Enter] key to display the submenu. " USB Configuration Submenu" (p.211) 210 PRIMERGY BX620 S4 Server Blade User’s Guide  USB Configuration Submenu table: Items on the USB Configuration Submenu Item Setting Description Module Version - Displays the USB code version of the AMI BIOS. USB Devices Enabled - Displays the number of the connected USB devices. USB Functions 4 USB Ports (Unchangeable) Sets whether or not to use the hardware conforming to the USB standard. USB 2.0 Controller Enabled (Unchangeable) Sets whether or not to enable the USB-based controller (standard 2.0). This item appears when [USB Functions] is set to [4 USB Ports]. Legacy USB Support Auto (Unchangeable) Sets whether or not to use the USB-connected keyboard and mouse. This item appears when [USB Functions] is set to [4 USB Ports]. USB Mass Storage Device Configuration - Press the [Enter] key to display the [USB Mass Storage Device Configuration] submenu. This item appears when the device is connected via USB. 20Sec (Unchangeable) Sets the number of seconds to wait for a response after USB Mass Storage Device has been initialized during POST. USB Mass Storage Reset Delay Device #1 - Displays the connected device. Emulation Type (Device #1) Auto (Unchangeable) Sets the type of the connected device. This item appears when a USB Mass Storage Device is connected. Device #2 - Displays the connected device. Emulation Type (Device #2) Auto (Unchangeable) Sets the type of the connected device. This item appears when a USB Mass Storage Device is connected. 211 Chapter 8 Hardware Configuration/Utilities 8.2.5 PCI Configuration Submenu This submenu appears when [PCI Configuration] is selected from the Advanced menu. It configures the PCI device. BIOS SETUP UTILITY Main Advanced Security Server Boot PCI Configuration Onboard Disk OPROM Onboard LAN 1 OPROM Onboard LAN 2 OPROM Onboard LAN 3 OPROM Onboard LAN 4 OPROM Onboard LAN 5 OPROM Onboard LAN 6 OPROM PCI slot OPROM Daughter Board OPROM [Enabled] [Enabled] [Disabled] [Disabled] [Disabled] [Disabled] [Disabled] [Disabled] [Disabled] Exit Exit Has to be enabled, for booting from internal SATA or SAS- Hard Disk +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the PCI Configuration Submenu Item 212 Setting Description Onboard Disk OPROM • Disabled • Enabled (Initial value) Sets whether or not to initialize the extended ROM of each device. Onboard LAN1 OPROM • Disabled • Enabled (Initial value) Onboard LAN2 OPROM to Onboard LAN6 OPROM • Disabled (Initial value) • Enabled Note:  Change the setting of the device that is used for booting to [Enable]. PCI slot OPROM • Disabled (Initial value) • Enabled Daughter Board OPROM • Disabled (Initial value) • Enabled PRIMERGY BX620 S4 Server Blade User’s Guide 8.2.6 CPU Configuration Submenu This submenu appears when [CPU Configuration] is selected from the Advanced menu. It configures CPU settings. BIOS SETUP UTILITY Advanced Main Security Server Boot CPU Configuration C1E Support Hardware Prefetcher Adjacent Cache Line Prefetch Vanderpool Technology Execute Disable Bit Intel(R) SpeedStep(tm) tech. Intel(R) C-STATE tech. [Disabled] [Enabled] [Enabled] [Disabled] [Disabled] [Disabled] [Disabled] Exit Exit This should be enabled in order to enable or disable the Hardware Prefetcher Disable Feature. +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the CPU Configuration Submenu Item Setting Description C1E Support Disabled (Unchangeable) Hardware Prefetcher Enabled (Unchangeable) Adjacent Cache Line Prefetch • Disabled • Enabled (Initial value) Sets the use of the CPU cache access function. Vanderpool Technology • Disabled (Initial value) • Enabled Sets the use of virtualization technology. Execute Disable Bit • Disabled (Initial value) • Enabled Sets the use of the security function to avoid buffer overflow. Intel(R) SpeedStep(tm) tech. • • • • Sets the CPU power saving function. This item is not supported when the Xeon processor E5405 (2GHz/12MB) CPU is used. Intel(R) C-State tech. Disabled (Unchangeable) Maximum Minimum Automatic Disabled (Initial value) The CPU internal setting. Note:  This item can be selected only immediately after power is supplied. The item cannot be selected during startup. Sets the function to optimize the performance and power status by moving the CPU status according to the load. 213 Chapter 8 Hardware Configuration/Utilities 8.2.7 Security Menu This menu configures the security features. BIOS SETUP UTILITY Main Advanced Security Server Boot Exit Install or Change the password. Security Settings Supervisor Password :Not Installed User Password :Not Installed Change Supervisor Password Change User Password +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Security Menu Item 214 Setting Description Supervisor Password/User Password - Displays whether each password is set or not. [Not installed] appears when the password is not set, and [Installed] appears when it is set. Change Supervisor Password - Press the [Enter] key to display the administrator password setting window. The administrator password prevents unauthorized startup of the BIOS Setup Utility. For details about procedures for setting, changing, and deleting the password, refer to "9.4.2 Security against Unauthorized Use" (pg.248). Change User Password - Press the [Enter] key to display the user password setting window. The system password prevents unauthorized access to the system. An administrator password must be specified. For details about procedures for setting, changing, and deleting the password, refer to "9.4.2 Security against Unauthorized Use" (pg.248). Clear User Password - Selecting this item and pressing the [Enter] key will delete the user password. This item appears when [User Password] is specified. Password Check • Setup (Initial value) • Always Sets the scope protected by the password. This item appears when [Supervisor Password] or [User Password] is specified. • Setup When starting the BIOS Setup Utility, entering the password is required. • Always When starting the system or BIOS Setup Utility, entering the password is required. PRIMERGY BX620 S4 Server Blade User’s Guide table: Items on the Security Menu Item Supervisor Password Lock Setting • Standard (Initial value) • Extended Description Set the scope protected by the setup password. This item appears when [Supervisor Password] or [User Password] is specified. 215 Chapter 8 Hardware Configuration/Utilities 8.2.8 Server Menu This menu configures memory and CPU. BIOS SETUP UTILITY Main Advanced Security Server Boot Server Configuration Post Errors [Enabled] Exit Exit Wait for F1 key to be pressed if error occurs. ASR&R CPU Status Memory Status Console Redirection System Information +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Server Menu Item 216 Setting Description Post Errors Enabled (Unchangeable) Sets whether to cancel system startup and stop the system when a Power On Self Test (POST) error is detected. ASR&R - Configures ASR&R setting. Press the [Enter] key to display the submenu. "8.2.9 ASR&R Submenu" (pg.217) CPU Status - Configures CPU setting. Press the [Enter] key to display the submenu. "8.2.10 CPU Status Submenu" (pg.220) Memory Status - Configures a memory setting. Press the [Enter] key to display the submenu. "8.2.11 Memory Status Submenu" (pg.221) Console Redirection - Configures console settings. Press the [Enter] key to display the submenu. "8.2.12 Console Redirection Submenu" (pg.222) System Information - Configures system settings. Press the [Enter] key to display the submenu. "8.2.13 System Information Submenu" (pg.223) PRIMERGY BX620 S4 Server Blade User’s Guide 8.2.9 ASR&R Submenu This submenu appears when [ASR&R] is selected from the Server menu. It configures ASR&R settings. BIOS SETUP UTILITY Main Advanced Security Server Boot Exit Exit Enable/Disable OS Boot Watchdog Timer ASR&R OS Boot Watchdog Timer Boot Retry Counter ASR&R Boot Delay(Minute) After Power Failure [Disabled] [Retry 3 times] [ 2] [Last State] +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. 217 Chapter 8 Hardware Configuration/Utilities table: Items on the ASR&R Submenu Item OS Boot Watchdog Timer Setting • Disabled (Initial value) • Enabled Description Sets whether to enable or disable the OS Boot Monitoring function, when ServerView is installed to the OS. If for some reason booting the operating system is interrupted when this function is enabled, the system will automatically restart. The OS Boot Monitoring function can also be enabled or disabled from ServerView. Note:  If ServerView is not installed to the OS, be sure to set the OS Boot Watchdog Timer to [Disabled]. If the setting is set to [Enabled], the server may automatically turn off or restart unexpectedly. Even when ServerView is installed on the OS, if starting the system while the "Server Management Tools" disk is inserted, be sure to disable the "OS Boot Monitoring" function. If the system is started with this function enabled, the server may automatically turn off or restart improperly. If the OS Boot Monitoring function is needed, it should be reset to enabled before resuming normal server operation. When setting this function, refer to "ServerView User's Guide" to fully learn about its specifications, in order to use it properly with the correct settings. 218 Timer Count Down Value • 2 Minutes • 5 Minutes • 10 Minutes (Initial value) • 15 Minutes • 20 Minutes • 30 Minutes • 60 Minutes • 100 Minutes Sets the monitoring time of the "OS Boot Monitoring" function. This item appears when [OS Boot Watchdog Timer] is set to [Enabled]. Timer Count Action • • • • Sets the operation when the OS did not boot successfully within the time set with the [Timer Count Down Value] setting. This item appears when [OS Boot Watchdog Timer] is set to [Enabled]. • No Action: Takes no action. • Reset: Restarts the system. • Power Off: urns the server off. • Power Cycle: Turns the server off and back on again. No Action Reset (Initial value) Power Off Power Cycle PRIMERGY BX620 S4 Server Blade User’s Guide table: Items on the ASR&R Submenu Item Boot Retry Counter Setting • • • • • • • • No Retry Retry1 time Retry2 times Retry3 times (Initial value) Retry4 times Retry5 times Retry6 times Retry7 times Description Sets the maximum number of retries to boot the operating system within the range of 0 to 7. ASR&R Boot Delay (Minute) 2 (Unchangeable) Sets the standby time for startup after shutdown due to trouble (such as overheating) in minutes. The system restarts after the set standby time. After Power Failure • Stay Off • Last State (Initial value) • Power On Sets the server operation when power supply is restored after power failure or turning on the main power of the Chassis. • Stay Off The power stays turned off. • Last State The power state before the power failure is restored. • Power On The power is turned on. Note:  When a UPS scheduled operation is performed in an OS such as Windows Server 2003 and Linux, in which the power turns off after shutdown, set this item to [Power On]. If this is not set to [Power On], the server will not start up automatically at the specified time. 219 Chapter 8 Hardware Configuration/Utilities 8.2.10 CPU Status Submenu This submenu appears when [CPU Status] is selected from the Server menu. It configures CPU status setting. BIOS SETUP UTILITY Main Advanced Security Server Boot CPU Status * CPU1 Status: CPU2 Status: [Enabled] [Enabled] Exit Exit If a CPU is failed but equipped, the Service Processor has stopped the CPU on demand or due to CPU errors. Status of empty CPU slot is unchangeable. +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the CPU Status Submenu Item CPU1 Status CPU2 Status 220 Setting Enabled (Unchangeable) Description Displays the CPU status. After replacing the CPU, set to [Enabled]. PRIMERGY BX620 S4 Server Blade User’s Guide 8.2.11 Memory Status Submenu This submenu appears when [Memory Status] is selected from the Server menu. It configures the memory setting. BIOS SETUP UTILITY Main Advanced Security Server Boot Memory Status Memory Scrubbing Memory Mirror [Enabled] [Disabled] DIMM DIMM DIMM DIMM [Enabled] [Enabled] [Enabled] [Enabled] 1,2 3,4 5,6 7,8 Exit Exit If enabled the whole memory will be scrubbed to prevent uncorrectable memory errors. +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Memory Status Submenu Item Setting Description Memory Scrubbing Enabled (Unchangeable) Sets whether or not to use the Memory Scrubbing function. By using the Memory Scrubbing function, and accessing each memory in order, memory errors can be fixed. Memory Mirror • Disabled (Initial value) • Mirror Sets whether or not to use the memory redundancy function. If using the redundant memory function installing ServerView is necessary. DIMM 1, 2 Enabled (Unchangeable) Displays the memory status. After replacing memory, set to [Enabled]. DIMM 3, 4 DIMM 5, 6 DIMM 7, 8 221 Chapter 8 Hardware Configuration/Utilities 8.2.12 Console Redirection Submenu This submenu appears when [Console Redirection] is selected from the Server menu. It configures detailed settings for console redirection. BIOS SETUP UTILITY Main Advanced Security Server Boot Exit Exit Console Redirection Com Port Address Protocol Flow Control Mode [On-board COM A] [ANSI] [XON/XOFF] [Standard] +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Console Redirection Submenu Item 222 Setting Description Com Port Address • Disabled • On-board COM A (Initial value) Sets whether or not to perform console redirection using a serial port. Protocol ANSI (Unchangeable) Sets a terminal type of a remote host when console redirection is used. This item appears when [Com Port Address] is set to [On-board COM A]. Flow Control XON/XOFF (Unchangeable) Sets flow control when console redirection is set. Only [XON/XOFF] is available in this Server Blade. This item appears when [Com Port Address] is set to [On-board COM A]. Mode • Standard (Initial value) • Enhanced Sets whether or not to continue console redirection after POST when console redirection is set. This item appears when [Com Port Address] is set to [On-board COM A]. PRIMERGY BX620 S4 Server Blade User’s Guide 8.2.13 System Information Submenu This submenu appears when [System Information] is selected from the Server menu. It configures System Information setting. BIOS SETUP UTILITY Main Advanced Security Server Boot Exit Exit System Information Manufacturer:Intel Brand String:Genuine Intel(R) CPU 3.00GHz Frequency :3.00GHz FSB Speed :666MHz Stepping :F62 Cache L1 Cache L2 On On On On On On Board Board Board Board Board Board :32 KB :4096 KB LAN1 LAN2 LAN3 LAN4 LAN5 LAN6 Mac Mac Mac Mac Mac Mac Address: Address: Address: Address: Address: Address: nn:nn:nn:nn:nn:nn nn:nn:nn:nn:nn:nn nn:nn:nn:nn:nn:nn nn:nn:nn:nn:nn:nn nn:nn:nn:nn:nn:nn nn:nn:nn:nn:nn:nn +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the System Information Submenu Item Setting Description Manufacturer - Displays the name of the installed CPU vendor. Brand String - Displays the CPU name and frequency. Frequency - Displays the CPU frequency. FSB Speed - Displays the FSB speed. Stepping - Displays the CPU stepping. Cache L1 - Displays the L1 cache. Cache L2 - Displays the L2 cache. On Board LAN1 Mac Address to On Board LAN6 Mac Address - Displays the MAC address of On Board LAN1 to On Board LAN6. 223 Chapter 8 Hardware Configuration/Utilities 8.2.14 Boot Menu This menu sets OS startup options. BIOS SETUP UTILITY Main Advanced Security Server Boot Exit Select Power-on state for Numlock. Boot Settings Bootup Num-Lock [On] Boot Device Priority Hard Disk Drives +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Boot Menu Item Description Bootup Num-Lock • Off • On (Initial value) Sets NumLock state at start up. Boot Device Priority - Sets from which drive and in which order the OS should be read. Press the [Enter] key to display the submenu."8.2.15 Boot Device Priority Submenu" (pg.225) Hard Disk Drives - Sets the priority sequence for each device. Press the [Enter] key to display the submenu. "Removable Drives" and "CD/DVD Drives" are displayed when the USB device is connected. Removable Drives CD/DVD Drives 224 Setting PRIMERGY BX620 S4 Server Blade User’s Guide 8.2.15 Boot Device Priority Submenu This submenu appears when [Boot Device Priority] is selected from the Boot menu. It sets from which drive and in which order the OS should be read. BIOS SETUP UTILITY Main Advanced Security Server Boot Exit Boot Device Priority 1st 2nd 3rd 4th 5th Boot Boot Boot Boot Boot Device Device Device Device Device +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Boot Device Priority Submenu Item Setting Description 1st Boot Device to 5th Boot Device (Set the boot order.) • [USB:Y-E USB-FDU] *1 • [USB:GENERIC CDR****] *1 • [SCSI:#***ID**LUN] • [Network:MBAv*.*.*] • [Network:MBAv*.*.*] *2 Sets the boot priority sequence for each device. Use the [+] [-] keys to change the order of priority for the selected device while shifting it one by one. You can also replace the priority order between two devices specified in the steps below. 1. Select the first device to change the priority sequence, and press the [Enter] key. 2. Select a device to replace the priority level with the initially selected device, and press the [Enter] key. *1: Displayed when USB-connected floppy disk or DVD-ROM unit is connected. *2: Displayed when the "Onboard LAN2 OPROM" setting in the Advanced menu "8.2.5 PCI Configuration Submenu" (pg.212) is changed to [Enabled].  Do not set a device selected in this menu to [Disabled]. 225 Chapter 8 Hardware Configuration/Utilities 8.2.16 Exit Menu This menu exits the BIOS Setup Utility. BIOS SETUP UTILITY Main Advanced Security Exit Options Save Changes and Exit Discard Changes and Exit Load Previous Value Server Boot Exit Exit system setup after saving the changes. F10 key can be used for this operation. Get Default Values +Tab F1 F10 Esc Select Screen Select Item Change Option Select Field General Help Save and Exit Exit v0n.nn (C)Copyright 1985-2004, American Megatrends, Inc. table: Items on the Exit Menu Item 226 Description Save Changes and Exit Saves the current settings in CMOS and exits the BIOS Setup Utility. After it exits the server reboots. Discard Changes and Exit Exits the BIOS Setup Utility without saving current settings. Previously saved settings remain valid. Load Previous Value Sets all set values to the currently stored values. Get Default Values Loads and displays the default settings for the server. Chapter 9 Operation and Maintenance This chapter explains the maintenance to be performed after server operations start. 9.1 9.2 9.3 9.4 9.5 9.6 9.7 9.8 9.9 Daily Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Event Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Restoring the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reinstalling the OS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance & Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . 228 229 243 248 251 254 257 258 260 227 Chapter 9 Operation and Maintenance 9.1 Daily Maintenance This section explains how to perform maintenance during operations.  PRIMERGY information For the latest information on PRIMERGY, update modules, drivers and the software, refer to the Fujitsu PRIMERGY website. http://www.fujitsu.com/global/services/computing/server/ia/driver/ Regarding BIOS and firmware, contact to Fujitsu Support Office. Refer to the following website. http://www.fujitsu.com/global/contact/computing/PRMRGY_index.html 9.1.1 Checking the Server Condition Use the status LED and server monitoring tool to check the server status.  Checking each LED This server is equipped with LEDs that display various hardware conditions. Check the server status via each LED after starting the server. For details about the location and function for each status display LED, refer to "1.3 Component Names and Functions" (pg.27) and "Chapter 1 Component Names and Functions" in the "BX600 S3 Blade Server System Unit Hardware Guide".  Server Monitoring Tool (ServerView) ServerView is software that monitors whether the server hardware is in a normal state to protect important server resources. When using ServerView, the server hardware is monitored all the time. Early detection of errors is made possible because if an error that could cause trouble is detected, the administrator is notified in real-time. This allows the server administrator to remove system errors early and avoid trouble. For an overview of and details about installation of ServerView and other high reliability tools, refer to "1.2.2 High Reliability Tools" (pg.23) and "Chapter 6 High Reliability Tools" (pg.163).  Check using Management Blade The Management Blade is equipped with two management interfaces (Web UI and CLI) that enable you to monitor whether the server hardware is running properly. For details about the Management Blade, refer to "BX600 Management Blade Hardware Guide". 228 PRIMERGY BX620 S4 Server Blade User’s Guide 9.2 Troubleshooting This section explains the corrective actions to be taken when the server is not running properly or when error messages are displayed. Depending on the situation, refer to the following. • Hardware problems: "9.2.1 Hardware Troubleshooting" (pg.229) • Error messages: "9.2.2 Error Messages" (pg.234) • Software problems: "9.2.3 Software Troubleshooting" (pg.238) If the problem is not resolved after performing the following troubleshooting, contact an office listed in the "Contact Information" of the "Start Guide". When contacting an office listed in the "Contact Information" of the "Start Guide", "9.8.2 Contacting Maintenance Support" (pg.259) and collect the required information.  PRIMERGY information For the latest information on PRIMERGY, update modules, drivers and the software, refer to the Fujitsu PRIMERGY website. http://www.fujitsu.com/global/services/computing/server/ia/driver/ Regarding BIOS and firmware, contact to Fujitsu Support Office. Refer to the following website. http://www.fujitsu.com/global/contact/computing/PRMRGY_index.html 9.2.1 Hardware Troubleshooting This section explains hardware related troubleshooting. If it does not operate properly or if a failure is suspected, check the following. For optional devices, refer to the optional device manuals.  Chassis  The main power of the Chassis will not turn on, or the power LED on the front of the Chassis does not light up • Check to see whether the power cable of the Chassis is properly connected to the outlet. For instructions on connecting the power cable, refer to the "Start Guide". • The main power of the Chassis may have been turned on within 2 minutes of the power cable being connected. Turn the power on after 2 minutes has lapsed. 229 Chapter 9 Operation and Maintenance  Server Blade  The Server Blade will not turn on, or the power LED on the front of the Server Blade does not light up • Check whether the Server Blade is securely installed in the Server Blade slot of the Chassis. • Check whether the main power of the Chassis is turned on. • Check to see whether the power cable of the Chassis is properly connected to the outlet. For details, refer to the "Start Guide".  The Server Blade will not turn on, or the KVM select LED blinks Check whether the number of installed Server Blades exceeds the limit For details, refer to "4.2 Installing Server Blades/Storage Blades" in "BX600 S3 Blade Server System Unit Hardware Guide".  The hard disk access LED does not light up The Server Blade may be damaged. Contact an office listed in the "Contact Information" of the "Start Guide". When contacting an office listed in the "Contact Information" of the "Start Guide", refer to "9.8.2 Contacting Maintenance Support" (pg.259) and collect the required information.  An error message is displayed Refer to "9.2.2 Error Messages" (pg.234).  The LAN does not operate properly The Switch Blade may not be running properly. Check the Switch Blade settings.  Switch Blade If there is a problem with network connection, first check the wiring and confirm that the device is normally connected to network. If the error still occurs, refer to the following.  Switch indicator diagnosis There is a device connected to a port of the Switch Blade, but the link LED is off • Check that the Switch Blade and connected device are turned on. • Check that the cable is connected to both the Switch Blade and device. • Check that the cable type is appropriate and the cable length does not exceed the allowable range. • Check that there are no defects in the connection between the cable and adapter of the connected device. Replace the defective cable or adapter as required. • Check that all the system components are installed correctly. If the network cable does not function normally, execute a test in an environment where all the components other than the cable function normally. 230 PRIMERGY BX620 S4 Server Blade User’s Guide  There are problems accessing the management interface The management interface of the switch board can be accessed from anywhere in the connected network using Telnet, Web browser, or SNMP-based network management software. If there are problems accessing the management interface, check the following. Cannot connect to the Switch Blade using Telnet, Web browser, or SNMP software • Check that the appropriate IP address, subnet mask, and default gateway are set to the agent. • When connecting to the agent with the IP address in the tagged VLAN group, check that the management station includes an appropriate tag in the sending frame. • Check that the Switch Blade is appropriately connected to network, and also check that the port used is enabled. • Check the network cable between the management station and Switch Blade. • If connection using Telnet cannot be enabled, four active sessions may already be opened. Try connecting after waiting for a while. • When using a spanning tree, check the connection state 30 seconds after the cable has been connected. Cannot access the setup screen of the Switch Blade in the serial port connection of the Management Blade Check that serial port and terminal emulator settings are correct by referring to "BX600 Management Blade Hardware Guide". Forgot or lost your password Refer to the Switch Blade manual, and perform password initialization of the Switch Blade that will be used. Failed to open the management screen using the Web browser during connection with the network • Switch Blade may not reboot when the Management Blade console redirection function is used. Exit Console Redirection temporarily. • Main power could be off when using the Management Blade console redirection function. Exit Console Redirection temporarily.  Other Communication failure between the Switch Blade and connected switch occurred Is the LAN cable connected using wiring that causes a network loop? Review the connection, or enable spanning tree settings between the cable and switch. 231 Chapter 9 Operation and Maintenance  Display  The display will not turn on Check to see whether the power cable of the display is properly connected to the outlet. For instructions on connecting the power cable, refer to the "Start Guide" as well as the manual of the display.  Nothing is displayed on the screen • Check to see whether the KVM select LED of the Server Blade that you wish to display the screen lights up green. When the LED does not light up, press the KVM select switch. • Check to see whether the cable of the display is properly connected to the outlet. If it is not connected, turn the server off, and correctly connect the cable. • For instructions on connecting the cable, refer to the "Start Guide". • Check that the brightness volume and contrast volume of the display are adjusted correctly. If they need to be adjusted, perform the necessary adjustments. For details, refer to the manual of the display. • There may be an error in the system area of the memory. Contact an office listed in the "Contact Information" of the "Start Guide".  Typing the keyboard does not display any characters, or the mouse cursor does not move • Check to see whether the keyboard and mouse are connected properly. If they are not connected, turn the server off and then connect the cables to the server. For the connection procedures, refer to the "Start Guide". • Another server blade may be selected by the KVM select function. Press the KVM select switch.  The screen shakes If an object that produces a strong magnetic field such as a television or a speaker is near the display, move it further away from the display. The display may also shake if a nearby cell-phone receives a call. Do not use a cell-phone near the display.  The screen display is distorted During 3D program execution in Windows Server 2003, Windows Server 2003 R2, Windows Server 2003 x64, or Windows Server 2003 R2 x64, the screen display may malfunction or the 3D program may terminate abnormally. If this occurs, set Color quality in screen properties to anything other than True Color (32 bits). 232 PRIMERGY BX620 S4 Server Blade User’s Guide  Floppy disk drive  Cannot read or write to the floppy disk Prolonged use of the floppy disk drive accumulates dust on the device head (the part which reads/writes data). A dirty head can impair the ability to read/write data to/from a floppy disk correctly. Clean the head once every three months.  Cannot write to the floppy disk • Check to see whether the floppy disk drive is properly connected to the Server Blade. For more information on the connection procedures, refer to the "Start Guide". • The write protection of the floppy disk may be applied. Flip the switch on the disk to allow writing.  CD/DVD drive  Cannot read data • Check to see whether the CD/DVD drive is properly connected to the Server Blade. For more information on the connection procedures, refer to the "Start Guide". • The CD/DVD drive may not properly be recognized on the OS. Check the settings. For details, refer to the CD/DVD drive manual. • Check to see whether the CD/DVD is inserted properly. If it is not, correctly insert the CD/DVD so that the label is facing up. • Check to see that the CD/DVD is not dirty. If it is dirty, wipe it with a soft, dry cloth. • Check to see that the CD/DVD is not scratched or bent. If scratched or damaged, replace the CD/ DVD.  The unit does not operate properly • Check to see whether the cable is connected properly. If it is not, correctly connect the cable. For more information on the connection procedures, refer to the "Start Guide" and the CD/DVD drive manual.  SCSI device (internal/external)  The unit does not operate properly • Check to see whether the SCSI cable is connected properly. If it is not, correctly connect the cable. • For more details on the internal hard disk unit, refer to "7.7 Installing an Internal Hard Disk Unit" (pg.197). • Check that the jumper pins are set correctly. Set them if they are not set correctly. • Check that the SCSI-ID and terminator are set correctly. Set them if they are not set correctly. 233 Chapter 9 Operation and Maintenance 9.2.2 Error Messages This section explains the error messages for this server.  POST error messages If an error occurs during Power On Self Test, a device check performed during the server startup, (POST), deal with it according to the following table.  When checking/changing the settings of the BIOS Setup Utility, refer to "8.2 BIOS Setup Utility" (pg.205).  For instructions on checking peripheral connections, refer to the "Start Guide".  For details on installing internal options, refer to "Chapter 7 Installing Internal Options" (pg.171). table: List of POST Error Messages Message OS booting has failed. Check to see whether the drives (hard disk, CD/DVD drive, floppy disk drive, etc.) and cables to be used for booting have no error. If the message still appears, the Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". Invalid Boot Diskette Booting disk error has occurred. Check to see whether the drives (hard disk, CD/DVD drive, floppy disk drive, etc.) and cables to be used for booting have no error. If the message still appears, the Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". Reboot and Select proper Boot device or Insert Boot Media in selected Boot device and press a key No drive to boot OS is detected. Check to see whether the drives (hard disk, CD/DVD drive, floppy disk drive, etc.) and cables to be used for booting have no error. If the message still appears, the Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". Interrupt Controller-1 error An interrupt controller error has occurred. The Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". Interrupt Controller-2 error 234 Contents and troubleshooting Boot Failure CMOS Battery Low CMOS battery (button battery) is close to burned out. Contact an office listed in the "Contact Information" of the "Start Guide". CMOS Checksum Bad A CMOS setting or checksum error has occurred. Correct the current settings using the BIOS Setup Utility or restore the default settings. If the message still appears, the Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". CMOS Date/Time Not Set The time and date may not be set. Enter the correct time and date on "8.2.2 Main Menu" (pg.208) of the BIOS Setup Utility. PRIMERGY BX620 S4 Server Blade User’s Guide table: List of POST Error Messages Message Contents and troubleshooting NVRAM Checksum Bad, NVRAM Cleared A NVRAM checksum error has occurred. Replace the Server Blade. Contact an office listed in the "Contact Information" of the "Start Guide". Keyboard/Interface Error The keyboard or keyboard connector is not connected properly. Check to see whether the keyboard is connected properly. If the message still appears, replace the key board, Server Blade, or KVM module. Contact an office listed in the "Contact Information" of the "Start Guide". Cache Memory Error A cache memory error in the CPU has occurred. Replace the CPU. Contact an office listed in the "Contact Information" of the "Start Guide". Gate20 Error A chip set error has occurred. The Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". DMA-1 Error A DMA error has occurred. The Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". DMA-2 Error DMA Controller Error Resource Conflict Static Resource Conflict PCI I/O conflict: PCI ROM conflict: PCI IRQ conflict: A conflict occurred between resources. Correct the current settings using the BIOS Setup Utility or restore the default settings. If the message still appears, the Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". A conflict occurred between PCI settings or an error has occurred. Replace the Server Blade. Contact an office listed in the "Contact Information" of the "Start Guide". PCI IRQ routing table error No enough Space to copy PCI Option ROM Warning:Now CPU1 Max support Freq. doesn't match with last time. Press F1 use the present CPU1 or shutdown to change CPU1. Warning:Now CPU2 Max support Freq. doesn't match with last time. Press F1 use the present CPU2 or shutdown to change CPU2. CPU Mismatch Error: CPU1 and CPU2 Frequency mismatch! CPU Mismatch Error: CPU1 and CPU2 Stepping mismatch! CPU Mismatch Error: CPU1 and CPU2 System Bus Frequency mismatch! A CPU error has occurred. Correct the current settings using the BIOS Setup Utility or restore the default settings. If the message still appears, replace the faulty CPU. If the message still appears, the Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". CPUs with varying frequencies are installed together. Correct the current settings using the BIOS Setup Utility or restore the default settings. If the message still appears, replace the faulty CPU. If the message still appears, the baseboard must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". CPU Mismatch Error: CPU1 and CPU2 Cache Size mismatch! H/W malfunction! A hardware error has occurred. The Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". Warning:DIMM Type Mismatch, has Log. The DIMM has been Disabled! Varying types of memory modules have been installed together. Check the system event log and replace memory in the bank. 235 Chapter 9 Operation and Maintenance table: List of POST Error Messages Message Contents and troubleshooting Warning:Memory Mirror Feature could not be enabled. Since the memory configuration is invalid, the memory redundancy function is not available. When using the memory redundancy function, check that two or more even numbers of memory banks of the same size are installed. When not using the memory redundancy function, check that [Memory Mirror] is set to [Disabled] in "8.2.11 Memory Status Submenu" (pg.221) on the [Server] menu of the BIOS Setup Utility. If the message still appears, the Server Blade must be replaced. Contact an office listed in the "Contact Information" of the "Start Guide". Warning:DIMM Type mixed has Log. The DIMM has been Disabled! Varying types of memory modules have been installed together. Check the system event log and replace memory in the bank.  Server Management Tools error messages The following error messages may appear while executing Server Management Tools. In such cases, perform the corresponding corrective actions. If messages other than the following are displayed, contact an office listed in the "Contact Information" of the "Start Guide". table: Server Management Tools: List of Error Messages Message The inserted floppy disk is write-protected. Disable the write-protect, and then press the [R] key. Not ready writing drive A. Abort, Retry, Fail? The floppy disk is not inserted into the floppy disk drive. Insert the proper floppy disk ("Server Management Tools" disk), and then press the [R] key. ERROR:Fail to create data file. The following are possible causes. Check the floppy disk status. • The floppy disk is write-protected. Disable the writeprotect and retry. • The floppy disk is not inserted into the floppy disk drive. Insert the proper floppy disk, and then retry. • There is an error in the contents of the floppy disk. Create the "Server Management Tools" disk again. If this occurred while recovering BIOS information, configure the information using the BIOS Setup Utility. Then store the BIOS information. ERROR:Fail to write 1st CMOS data into data file. nn ERROR:Fail to write 2nd CMOS data into data file. nn ERROR:Fail to write ESCD data into the data file. nn ERROR:Fail to write SEEPROM data into the data file. nn ERROR:Fail to open data file. The file for recovering the BIOS information does not exist on this floppy disk. Insert the floppy disk on which the BIOS information was stored, and then retry. ERROR:Fail to write 1st CMOS data into system. The following are possible causes. Check the floppy disk status again. • The floppy disk is not inserted into the floppy disk drive. Insert the proper floppy disk, and then retry. • A different model or an unsupported version of BIOS information. Insert the proper floppy disk, and then retry. • There is an error in the contents of the floppy disk. Create the "Server Management Tools" disk again. If this occurred while recovering BIOS information, configure the information using the BIOS Setup Utility. Then store the BIOS information. ERROR:Fail to write 2nd CMOS data into system. ERROR:Fail to write ESCD data into system. ERROR:Fail to write SEEPROM data into system. 236 Description Write protect error writing drive A. Abort, Retry, Fail? PRIMERGY BX620 S4 Server Blade User’s Guide table: Server Management Tools: List of Error Messages Message Other messages Description Contact an office listed in the "Contact Information" of the "Start Guide". 237 Chapter 9 Operation and Maintenance 9.2.3 Software Troubleshooting This section explains software-related troubleshooting. For troubles during OS installation or system operation, refer to the following contents.  Trouble at a ServerStart startup  After a boot from PRIMERGY Startup Disc, nothing is displayed on the screen. This situation may occur if the hard disk drive still contains the previous information. In that case, this situation may occur even when insert Windows Server 2003 installation disc. In such a situation, physically format the hard disk drive to delete the previous information and start up ServerStart. For physical formatting for hard disk drive, refer to the manual in the Array Controller Document & Tool CD. For the manual of the SAS RAID Ctrl to be used, refer to "2.3.2 Notes on Configuring RAID" (pg.42)  Error messages during installation The following error messages may appear during installation using ServerStart. Observe the corrective action against the relevant error.  "WzDiskAdmin: System Error! ......................, Last Error: The device is not ready." appears Optional SCSI/SAS devices (e.g., hard disk cabinet, DAT unit) may be connected. Disconnect the optional SCSI/SAS devices and perform installation again. Connect the optional devices after the installation completes.  "Operating System not found" appears when the system restarts from the CD/DVD after file copy The following factor may be possibly root cause. • The Active flag is selected.  "Missing Operating System" appears during installation The installation partition size may be too large. Specify the installation partition size correctly. For details on the installation partition size, refer to "2.3.1 Installation Partition Size" (pg.42).  "Error 1920. Service (PXE Services) failed to start" appears during preconfigured installation The system installed with the preconfigured settings (PXE server) may not be connected to the network. Check the LAN cable connection and click [Rerun]. 238 PRIMERGY BX620 S4 Server Blade User’s Guide  Application software which uses tftp client function (tftp.exe) does not operate properly For the system on which Windows Server 2003 is installed, since the tftp client function (tftp.exe) is not installed by default, and application software which uses the tftp client function (tftp.exe) does not operate properly. To use the tftp client function (tftp.exe), install "tftp.exe" from the OS installation disc according to the following procedures. 1 Insert the OS installation disc into the CD/DVD drive. The OS installation disc must be any of Windows Server 2003 CD that has applied SP1, Windows Server 2003 x64 DVD or Windows Server 2003 R2 Disc 1 CD-ROM. 2 Start the Command Prompt and move to the i386 folder of the CD/DVD drive. 3 Execute the following command to extract "tftp.exe" in the "%Systemroot%\system32" folder. [CD/DVD drive]:\i386>expand -r:tftp.exe TFTP.EX_ %Systemroot%\system32 4 Confirm that "tftp.exe" exists in the "%Systemroot%\System32" folder.  Error window appears after installing or uninstalling ServerView (For Windows Server 2003) For Windows Server 2003 with Service Pack 1 applied, the following message may appear on restarting after installing/uninstalling ServerView. The operation will run properly. Click [Close Message] to close the message.. In order to protect the computer, this program is terminated by Windows. Name: SNMP Service  Error window appears after LAN driver installation (For Windows Server 2003) The following window may appear when the installation of the LAN driver to the [Ethernet controller] under [Other devices] starts. 239 Chapter 9 Operation and Maintenance This error results from that the LAN driver for the network adapter recognized immediately after the OS installation is not updated. Clicking [Finish] in this window displays the [Help and Support Center] window. Click [X] to close this window. The "!" mark is displayed at the LAN device name in Device Manager. The device names are displayed properly when all the LAN drivers are installed and the system is restarted.  LAN operation fails or error message appears during LAN driver installation A conflict may have occurred between system resources including the LAN and other expansion cards. Delete all the LAN drivers and check that conflicts between system resources do not exist. Then, restart the system and reinstall the LAN drivers again.  Event log errors after installation After installation, the following events may be displayed in Event Viewer. Check and perform the corrective action against the relevant event. table: List of event log errors that may occur after Installation ID Description Cause and corrective action 62 This computer is a domain PDC at the root of forest. Use the net command "net time /setsntp:" to configure it for synchronization from an external time source. Cause: An NTP was selected as a component. Corrective action: ServerStart cannot configure the NTP server due to the absence of items for specifying it. After OS installation, perform the following procedure to specify the time server. 1. Start SNTP server operation on another machine. For example, the SNTP server address is <172.22.78.246>. 2. Enter the following at a Command Prompt. net time /setsntp:172.22.78.246 w32tm -s 172.22.78.246 1000 The user or computer name cannot be identified. The return value is "1722". Cause: The primary DNS server address may be invalid or the server cannot be accessed. Corrective action: Perform the following procedures to correct the DNS address in Internet protocol (TCP/IP) properties. 1. Right-click [My Network] and click [Properties]. 2. Right-click [Local Area Connection] and click [Properties]. 3. Click [Internet Protocol (TCP/IP)] and click [Properties]. 4. Enter the correct DNS address in the [Primary DNS server] box.  Cannot collect the memory dump If the memory dump file cannot be created, perform the following procedures.  Correcting the settings If the memory dump cannot be collected, check the settings of the paging file and memory dump file. For setting procedures, refer to "5.1 Memory Dump/Paging File Setting" (pg.100). 240 PRIMERGY BX620 S4 Server Blade User’s Guide  Collecting memory dump to other than the system drive If the memory dump is set to be collected to the system drive (C:\), change the settings so that the memory dump can be saved to a drive other than the system drive. For setting procedures, refer to "5.1 Memory Dump/Paging File Setting" (pg.100). If only the system drive exists, or if there is no free space in any of the drives, perform one of the following: • Adding a hard disk unit • Replacing with a higher-capacity hard disk unit  Reducing the installed memory to collect the memory dump There must be enough free disk space that matches the size of the installed memory; therefore, reduce the installed memory to a collectable size. Check the memory dump settings when changing the installed memory size. For setting procedures, refer to "5.1 Memory Dump/Paging File Setting" (pg.100).  Changing the write type of the debugging information If the memory dump cannot be collected, select a write type of debugging information within the range of free space of the volume size. If the above does not provide a solution, try increasing the size of the hard disk or adding an additional hard disk unit. For setting procedures, refer to "5.1 Memory Dump/ Paging File Setting" (pg.100).  Restoring the system In the event where the system file, system configuration, or environment changes during startup are corrupted, use the repair information stored on the repair disk created at the installation to restore the system. For restoration procedures, refer to the following: • "9.6.1 For Windows Server 2008" (pg.254)  SNMP service startup fails If the Simple Network Management Protocol (SNMP) is installed, but has not started, perform the following procedures to start the service. 1 Click [Start] – [Computer Management]. 2 Select [Services] on the [Services and Applications] menu. 3 On the details, select [SNMP Service]. 4 Select [Start] on the [Action] menu.  To have the service automatically start each time the OS starts, double-click [SNMP Service] on the details, and select [Automatic] for the [Startup type] setting of the [SNMP Service Properties] window. 241 Chapter 9 Operation and Maintenance  Time display in Linux OS environment  Difference in time between the OS and the hardware clock Since the software clock on OS is employed but not the hardware clock functioned in the server for time display in Linux environment, time -lag may occur between the OS and the hardware clock. When time precision is required on OS, it is recommended to use the NTP service to periodically correct the time displayed on the OS.  Changing the time settings for the OS and hardware clock In a Linux environment, the time displayed on the OS (the software clock value on the OS) is written to the hardware clock in the server when the OS is shut down. • Procedure for prohibiting the time on the OS from being written to the hardware clock When you do not want the time on the OS to be written to the hardware clock at an OS shutdown, comment the following line out in /etc/rc0.d/S01halt. runcmd $"Syncing hardware clock to system time" /sbin/hwclock $CLOCKFLAGS ↓ #runcmd $"Syncing hardware clock to system time" /sbin/hwclock $CLOCKFLAGS • Procedure for reflecting the hardware clock value to the time on the OS To reflect the hardware clock value to the software clock value on the OS, run the following command. >hwclock --hctosys 242 PRIMERGY BX620 S4 Server Blade User’s Guide 9.3 System Event Log To operate system event log, use Server Management Tools This section explains how to use Server Management Tools.  The server settings are set so that when the System event log area in the server becomes full a new event log is automatically written over the old log areas. 9.3.1 Server Management Tools Server Management Tools perform the following to the system event log stored in the Baseboard Management Controller (BMC: a micro-controller used for managing the baseboard environment, such as its temperature and voltage sensors). • Viewing the system event log • Saving the system event log • Deleting the system event log When an system event log occurs, save the log using Server Management Tools and contact an office listed in the "Contact Information" in the "Start Guide".  The system event log of this Server Blade can be viewed from the management terminal via the Management Blade. → "BX600 Management Blade Hardware Guide".  The "Server Management Tools" disk is for this Server Blade only. Do not use those tools on other systems. If it is used, the system may be damaged.  To execute the Server Management Tools, follow the startup procedure shown in "9.3.2 Starting and Exiting Server Management Tools" (pg.244) to start the Server Blade. Do not run this tool on the server started from the hard disk drive or other floppy disks. Otherwise, the system may be corrupted.  Do not eject the floppy disk when the floppy disk access LED is on. Doing so may destroy the data on the floppy disk. 243 Chapter 9 Operation and Maintenance 9.3.2 Starting and Exiting Server Management Tools The steps for starting and exiting Server Management Tools are as follows:  Preparation for using Server Management Tools To use Server Management Tools, prepare the "Server Management Tools" disk of the server at hand. Use the Display/USB Extension Cable to connect to the floppy disk drive to the Server Blade. For details, refer to the "Start Guide".  Starting Server Management Tools  Before starting up the system from the "Server Management Tools" disk, first check that the ServerView "OS Boot Monitoring" function is disabled (default setting is "Disabled"). If you start up the system while the "OS Boot Monitoring" function remains enabled, the operation of the Server Blade may become unpredictable at such times as an abrupt power interruption or restart. If the "OS Boot Monitoring" function is needed, it should be reset to enabled before resuming normal server operation. For details of ServerView, refer to "ServerView User’s Guide". 1 Turn on the server and insert the "Server Management Tools" disk into the floppy disk drive. The window for selecting a keyboard appears. Please select: 1 = JP Keyboard 2 = US Keyboard Your selection 2 Select a keyboard. Select "1" for the Japanese keyboard or "2" for the English keyboard. The Japanese keyboard is selected by default. 244 PRIMERGY BX620 S4 Server Blade User’s Guide 3 When the DOS prompt window appears, enter the following command and press the [Enter] key. Enter the following command and press the [Enter] key. A:\>ipmiview Server Management Tools menu appears. FUJITSU SIEMENS COMPUTERS IPMI-Tool - Vn.nn General Information Temperature Information Fan Information Voltage Information System Event Log (SEL) FRU Information (ID Proms) FSC/System Specific Functions < > Select Start Exit 4 Select an item using [↑] or [↓] and press the [Enter] key. The screens that can be displayed are shown.  Only the following function is supported by Server Management Tools: • System Event Log (SEL) Operations of other items are not ensured.  Key operations The following shows the key operations in the menu window of Server Management Tools. table: List of Server Management Tools key operations Key Roles of key [↑][↓] Selects an item. [Enter] Executes the selected item. [Esc] Exits Server Management Tools.  Exiting Server Management Tools Press the [Esc] key once in the menu window of Server Management Tools. The power can be turned off when the DOS prompt is displayed. 245 Chapter 9 Operation and Maintenance 9.3.3 Viewing/Saving/Deleting the System Event Log Viewing, saving, and deleting the system event log is performed in the System Event Log (SEL) window.  Starting the [SYSTEM EVENT LOG (SEL)] window 1 Start Server Management Tools. 2 Select [System Event Log (SEL)], and press the [Enter] key. The [SYSTEM EVENT LOG (SEL)] window appears. FUJITSU SIEMENS COMPUTERS 004 003 002 001 000 < SYSTEM EVENT LOG (SEL) MMM-DD-YYYY MMM-DD-YYYY MMM-DD-YYYY MMM-DD-YYYY MMM-DD-YYYY HH:MM:SS HH:MM:SS HH:MM:SS HH:MM:SS HH:MM:SS [*****] [*****] [*****] [*****] [*****] **************************************** **************************************** **************************************** **************************************** **************************************** ,PgUp/Dn,(Ctrl-)Home/End> Move SaveToFile Clear Exit  Key operations The following shows the key operations in the System Event Log (SEL) window. table: List of System Event Log (SEL) window key operations Key Roles of keys [↑], [↓], [←], [→], [PageUp], [PageDown], [Ctrl]+[Home], [Ctrl]+[End] Scrolls the screen. [Esc] Ends the System Event Log (SEL) window and returns to the Server Management Tools menu window. [F2] Saves log. [F3] Erases log.  Saving logs 1 Press the [F2] key in the System Event Log (SEL) window. 2 Enter the name of the file to save the log, and press the [Enter] key. The logs are saved on a floppy disk with the specified file name. 246 PRIMERGY BX620 S4 Server Blade User’s Guide  Deleting logs When number of system event logs reaches the maximum (254 logs), the oldest log is overwritten with the newest log. Periodically start Server Management Tools to check the system event log and save/delete logs as necessary. The following shows the steps for deleting an event log. 1 Press the [F3] key in the System Event Log (SEL) window. The following window appears. FUJITSU SIEMENS COMPUTERS SYSTEM EVENT LOG (SEL) Clear SEL Exit 2 Press the [Enter] key. This deletes the system event log.  If you continue operations with event logs full, it is difficult to remedy a fault. Event logs should be periodically saved and deleted. 247 Chapter 9 Operation and Maintenance 9.4 Security Security features are provided in order to protect the Server Blade hardware and software resources from theft. Additional security functions against unauthorized use provided by the BIOS Setup Utility, etc. are also available to help maintain a highly reliable data security system. 9.4.1 Hardware Security For details on the hardware security, refer to "2.1 Hardware Security" in the "BX600 Management Blade Hardware Guide". 9.4.2 Security against Unauthorized Use A password can be set to prevent unauthorized use of the Server Blade. When a password is set, the server is accessible to only the users who know the password. The password is set in the BIOS Setup Utility. For details on the BIOS Setup Utility, refer to "8.2 BIOS Setup Utility" (pg.205).  Password types The following two types of password can be set in this Server Blade. The type of password defines the privileges of server operations.  Supervisor password (Administrator password) This is the password that allows specific persons to access the BIOS setup. Unless the set password is entered, the BIOS setup cannot be accessed and the OS cannot be booted.  User password (User password) This is the password that allows specific persons to use the Server Blade. Unless the set password is entered, part of the BIOS setup cannot be accessed and the OS cannot be booted. 248 PRIMERGY BX620 S4 Server Blade User’s Guide  Setting a password 1 Start the BIOS Setup Utility. "8.2.1 Starting and Exiting the BIOS Setup Utility" (pg.205) 2 Use the [←] [→] keys to select [Security] from the [Main] menu and press the [Enter] key. The [Security] menu appears. 3 Use the [↑] [↓] keys to select the type of password to set. • When setting an administrator password Move the cursor to [Change Supervisor Password] and press the [Enter] key. • When setting a user password Move the cursor to [Change User Password] and press the [Enter] key. The password entry window appears. 4 Enter a password in the [Enter New Password] up to six alphanumerical characters. Blocks are displayed instead of the letters entered. 5 Press the [Enter] key. To cancel the password setting, press the [Esc] key. 6 In the [Confirm New Password] field, enter the password you have entered in Step 4 and press the [Enter] key. Display in [Supervisor Password] or [User Password] changes from [Not Installed] to [Installed].  Logging on as a user enables you to set the user authority only, such as user password.  Changing and deleting a password If a password is already set, you can change or delete it in [Change Supervisor (User) Password]. 1 When changing a password, enter a new one in the [Enter New Password] field on the password entry screen. When deleting a password, execute step 3 without entering any characters. 2 When changing a password, enter the password entered in step 1 in the [Confirm New Password] again. When deleting a password, execute step 3 without entering any characters. 3 Press the [Enter] key. When the password is deleted, [Not installed] is displayed in [System Password] or [Setup Password] of the [Security] menu. 249 Chapter 9 Operation and Maintenance  The system shuts down after three invalid password entries. If this happens, turn off the Server Blade, turn it back on, and then enter the correct password.  If you forgot your password and cannot start the Server Blade, clear the CMOS with the switch block on the Server Blade to delete the password. After the CMOS has been cleared, restore the BIOS settings ("8.1 Switch Block Settings" (pg.204)). After this, return switch block settings to the original settings and use this utility to set a password. 9.4.3 Security When Disposing of the Server  Notes regarding the deletion of data from the hard disk when disposing of or transferring the server When disposing of or transferring a server that has been used, the data in the hard disk may be read and used for unforeseen purposes. To prevent confidential or important data from leaking out, the data on the hard disk must be wiped before disposal or transfer. However, wiping the hard disk is not an easy task. Simply initializing (formatting) the hard disk or deleting the files may give the pretense that the data no longer exists, but in reality the data is simply no longer accessible to the OS. However, it is still accessible to malicious individuals that can restore the data. Therefore, if confidential or important data is saved to the hard disk, in addition to the operations mentioned above, it is recommended to use third-party tools or services to wipe the data completely from the disk to prevent its restoration. When disposing of or transferring the server, it is the customer's responsibility to wipe data contained in the hard disk in order to prevent such important data from leaking. Also, if software license agreements prohibit unauthorized distribution of software (OS or application software), transferring the server without removing the software may violate the license agreements. These issues must be taken into consideration. 250 PRIMERGY BX620 S4 Server Blade User’s Guide 9.5 Backup This Server Blade utilizes high reliability components and hard disks, however, as a precautionary measure, it is recommended that periodic backups be made of the data. 9.5.1 Importance of Backups If the data on the server is backed up, it can be restored from the backup data in the event of data corruption in hard disk units due to hardware failures or operational errors. If backup are not created, restoration is impossible and your important data will be lost permanently. For anxiety-free system operation, be sure to perform periodic backups of the system. 9.5.2 Backup Devices, Software and Their Operations Backup operations differ depending on network operating systems, applications, and system operations. Contact an office listed in the "Contact Information" in the "Start Guide" and make backups using the following items. • Backup device (e.g., DAT72 unit) • Backup software (Standard backup software supplied with the OS, software for tape backup, etc.)  The Windows Server Backup function that is standardly provided with Windows Server 2008 can be used. However, backup to a tape library cannot be performed using the Windows Server Backup function. • Backup operations (schedules) Use our genuine backup devices and software. Observe the backup medium (tape) storage conditions. Mirroring/disk array systems  To improve system reliability, a mirroring or disk array system is recommended in addition to periodic backup creation. 251 Chapter 9 Operation and Maintenance  Notes on operating backups Notes on using backups are as follows. For details, refer to the device manuals.  Head cleaning Airborne dust and dust from the magnetic media can collect on the head of the magnetic tape device. To remove this dust, head cleaning must be implemented. Implement head cleaning when the device displays a cleaning request. Particularly DDS devices require periodic head cleaning, otherwise dust can cling to the magnetic head, creating a situation that cannot be cleaned using standard head cleaning methods, and eventually render the device useless. Also note that there is a limit to how many times the cleaning media can be used. Using cleaning media that has exceeded its life span will have no cleaning effect. Note these points especially when performing automatic backups with library devices.  Managing media life span Media is a consumable product that must be replaced regularly. Continued use of media exceeding its life span can have negative effects on the device (e.g. increase the speed of dust accumulation). The life span of media varies depending on the environment and operating conditions of the device, the type of backup software used, and other operating conditions, however, it is recommended that they be replaced sooner than later. As a guide to when the life span of the media will expire, write the date it was first used on the media.  Rotating media Perform backup operations using multiple mediums on a rotating basis. When using a single media cartridge repeatedly, backup data can be temporarily lost in the event the backup fails. Also if the hard disk fails during backup, the backup data cannot be recovered.  Avoid leaving media in devices Because the magnetic recording surface of the device is exposed, media can be easily affected by airborne dust when left inserted for a long period of time. Insert the media before using it, and remove the media after use, and then restore it to its case. Also note that some tape devices write management information to the tape when ejecting the media. If the power were to go out when the media is still in the device, this writing process will not be performed and the media may become corrupted. To avoid this, remove the media from the device when turning off the server/device.  Verifying data after backup Some backup software products provide data verification functions after backup is completed. Such functions will read and verify the data written to the media after backup is completed. This will increase the usage of the media, thus reducing the number of times it can be used for backups. Depending on the hardware being used, some devices perform "read after write" operations on data; note the points of this section as necessary. 252 PRIMERGY BX620 S4 Server Blade User’s Guide  Ejecting media after backup Some backup software products provide functions for ejecting media after backup is completed. Such functions will rewind the tape after backup is completed and then eject the media from the drive. Be sure to execute this function for autoloader/library devices. Depending on the structure of some servers, this function may cause the media to be ejected from an internal device of the server and hit the Chassis cover. If this is the case, open the cover when ejecting, or do not eject the media.  Media label types and positions When writing information such as the name on media, use the label that came with the media. The area in which a label can be posted on the media of each device varies. Failing to post labels in the designated area can damage the device.  Data storage When storing data for long periods of time, store the media in a location not affected by humidity and magnetic fields. 253 Chapter 9 Operation and Maintenance 9.6 Restoring the system If the system is damaged, use the backup data created after the installation to restore the system.  Backup data for system recovery must be created in advance. For the procedure for creating it, refer to "5.2 Creating Backup Data for System Recovery" (pg.107).  When using the backup device, refer to the manual provided with the backup device or Readme.txt included in the device driver. 9.6.1 For Windows Server 2008 The whole server can be restored using the Windows Server Backup function.  Items required • Windows Server 2008 DVD-ROM (Installation disc) • Backup data created using the Windows Server Backup function (connectable shared folder, DVD, etc.) 1 Insert the Windows Server 2008 DVD-ROM (Installation disc) immediately after turning on the server. Check that there is not already a floppy disk inserted in the floppy disk drive at this time. 2 When active area is specified on the hard disk, the following message is displayed on the bottom of the window. Press any key while the message is displayed. Press any key to boot ... The Windows Server 2008 setup window appears. 254 PRIMERGY BX620 S4 Server Blade User’s Guide 3 Click [Repair your computer] displayed in the bottom left of the window. 4 Click [Windows Complete PC Restore]. When using a shared folder to restore the system, the message [Valid location for backup cannot be found.] is displayed. Click [Cancel]. 5 Specify the backup type, and click [Next]. When backup data is in a folder on another machine, or when the backup data is not the latest data, select [Restore specific backup]. In this case, the window to specify a restoration target appears after clicking [Next]. Select the backup to be restored and click [Next]. When the backup data is stored on the network, specify the shared folder in which the backup data is stored from [Advanced Settings]. The window to set the restoration options appears. 6 Perform the settings as required, and click [Next]. The restoration settings completion window appears. 255 Chapter 9 Operation and Maintenance 7 Click [Finish]. The restoration start window appears. 8 Check the checkbox, and click [OK]. System restoration starts. After the restoration has completed, the system is automatically rebooted. After rebooting, the system is restored using the backup data.  For operation with a BitLocker drive encryption set, perform the encryption settings again after the system restoration. 9.6.2 For Windows Server 2003 • Items required • Windows Server 2003 CD/DVD • Automated System Recovery (ASR) floppy disk (created beforehand) • Backup media (created beforehand) • Driver disk (for onboard SCSI or onboard array) For details on the driver to be used, refer to "4.2.4 Installing Windows Server 2003" (pg.86). For how to create driver disks, refer to "4.1 Creating Driver Disks" (pg.70). 1 Insert the Windows Server 2003 CD/DVD after turning on the server. Check that there is not already a floppy disk inserted in the floppy disk drive at this time. 2 When a message prompting you to press the [F6] key appears immediately after the start of setup, press the [F6] key. 3 When a message prompting you to press the [F2] key appears, press the [F2] key. A message prompting you to insert the ASR floppy disk appears. 4 Insert the ASR floppy disk and follow the window instructions. 5 The system restarts and a message appears. Press the [F6] key. 6 Follow the window instructions to restore the system. Notes on Automated System Recovery  Automated System Recovery does not restore data files. 256 PRIMERGY BX620 S4 Server Blade User’s Guide 9.7 Reinstalling the OS This section explains the procedure for reinstalling the OS. 9.7.1 Checking before OS Reinstallation  Deletion of data from the disk Reinstallation deletes all disk contents. Save the necessary data and system configuration in a different location.  Other notes Any remaining notes are the same as those for initial installation. Make sure to check the settings in advance. 257 Chapter 9 Operation and Maintenance 9.8 Maintenance Service This section explains the details of the maintenance service. If the cause of the failure is uncertain or if the original condition cannot be restored, contact an office listed in the "Contact Information". For details about contact information, refer to the "Start Guide". 9.8.1 Maintenance Service  Maintenance support period The maintenance support period is for five years after the purchase of the server.  Non-durable components Depending on the environment and period of usage there will be non-durable components that require replacement within the warranty period. Customer's who have signed up to hardware maintenance contract will be provided with replacement parts free of charge and will have higher priority for replacement. Customer's not signed up to hardware maintenance contract will be charged for operation cost (including the maintenance parts) separately. Replacing non-durable components  To ensure stable operation of the server system, it is recommended that a maintenance service agreement be purchased.  Lifetime of non-durable components The lifetime of such components is calculated based on appropriate usage environments. Although the guaranteed range for operation is set between 10 and 35 °C, the lifetime is assumed at a constant average temperature of 25 °C.  For details about Chassis non-durable components, refer to "6.5 Non-durable Components" in BX600 S3 Blade Server System Unit Hardware Guide". 258 PRIMERGY BX620 S4 Server Blade User’s Guide 9.8.2 Contacting Maintenance Support Before contacting maintenance support, check the following.  Fill in the "Configuration Sheet" and "Accident Sheet" of "Configuration Sheets".  Item • Model name and product ID of the Chassis They are indicated on the label on the Chassis. For the label location, refer to the "Start Guide". • Model name and product ID of the Server Blade They are indicated on the label supplied with the Server Blade. For the label location, refer to the "Start Guide". • Hardware configuration (Types and locations of internal options) • Configuration information of Server Blade (Set values with BIOS Setup Utility) • OS used in Server Blade • LAN/WAN system configuration • Phenomena (what happened when doing what, what was displayed, etc.) • Date/time of occurrence • Environmental settings of the server • LED statuses • USB floppy disk drive • The latest "Server Management Tools" disk with a setting information stored  Maintenance work Note the following points for maintenance work: • The settings will revert to the default values when blades and other units are replaced for maintenance. After replacement, specify the set values required for operations again. • During maintenance work, the maintenance engineer may ask you to turn on the LEDs such as the maintenance LEDs. Please follow the instructions. 259 Chapter 9 Operation and Maintenance 9.9 Maintenance & Notes This section explains the details of the maintenance & notes. 9.9.1 Operations after Replacement of a SAS Module or an Expansion Card Slot Module If the SAS module or the expansion card slot module is replaced due to an error when the array controller function is used for this Server Blade, the logical drive of the array controller is initialized again after replacement. This is because the data integrity information showing whether data was written correctly on internal hard disk unit in the past is stored in the SAS module or the expansion card slot module. As the information is lost due to replacement, the initialization is automatically executed to ensure the data integrity. You can restore this information using maintenance tool just before the replacement and write back after the replacement, however, if you cannot restore the information because of the malfunction of the SAS module or the expansion card slot module, the initialization procedure starts. This does not mean hard disk failure as well as the initialization. For details of the initialization, refer to the manual in the Array controller Document & Tool CD. 260 Appendix This appendix explains the specifications for the server and internal options. It also covers how to recycle the products. A B C D E Server Blade Specifications . . . . . . . . . . . . . . . . . . . . . . . Specifications for Internal Options . . . . . . . . . . . . . . . . . . External Floppy Disk Drive (USB) Notes on Usage . . . . . . About Switch Blade (PG-SW107) Connection . . . . . . . . . Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 264 267 268 271 261 Appendix A Server Blade Specifications This section explains the specifications for the Server Blade. table: Server Blade Specifications Item Functions and Specifications Product Name PRIMERGY BX620 S4 Server Blade Type Diskless type PGUX624CA2 Product ID Chipset Standard (frequency/ cache/FSB) CPU Conversion kit(frequency/ cache/FSB) Number of multiplication Standard Memory Module Dual Core Intel® Xeon® Processor E5205 (1.86GHz/6MB/1066MHz) Quad Core Intel® Xeon® Processor L5410 (2.33GHz/12MB/FSB1333MHz) Dual Core Intel® Xeon® Processor X5260 (3.33GHz/6MB/FSB1333MHz) Quad Core Intel® Xeon® Processor E5405 (2GHz/12MB/FSB1333MHz) E5420 (2.5GHz/12MB/FSB1333MHz) X5460 (3.16GHz/12MB/FSB1333MHz) – 1 (Max. 2) 1GB (DDR2-667 FBD 512MB DIMM × 2) Redundancy Memory mirror Adding size 1GB / 2GB / 4GB / 8GB Maximum PCI slots PGUX624EA Intel 5000P + ESB2 32GB (4GB DIMM ×8 slots) For expansion board Standard: N/A, Option: PCI-X 64-bit/133MHz×1, or PCI-Express (x8) × 1 For PCI card Standard: N/A, Option: PCI-X 64-bit/133MHz×1, or PCI-Express (x4) × 1 Internal 2.5-inch hard disk drive Adding size Maximum 2 bays (hot-pluggable) 73.4GB/146.8GB (10,025rpm, SAS), 73.4GB (15,000rpm, SAS) 293.6GB (146.8GB × 2) CD/DVD drive Type: DVD-ROM drive unit (USB external option) *1 Floppy disk drive Option (USB floppy disk drive) *1 VGA chip: ATI ES1000 Video RAM capacity: 16MB Resolution: 640×480, 800×600, 1024×768, 1280×1024 Display colors: Differ depending on resolution and OS. Video Onboard controller SAS LSI 1068 (2 port use, SAS module, IME array function) LAN Broadcom BCM5715S (1Gbps, Dual port) × 3 Security chip – Video *2 keyboard *2 1 (PS/2) Mouse *2 1 (PS/2) SAS Internal I/O port SerDes (LAN) SerDes (LAN/FC) 262 2 6 (1Gbps) 2 (For expansion board, Max. 10Gbps) Serial 1 (for system management) I2C 1 (for system management) USB External I/O port 1 (Analog RGB) 1 (USB 1.1) Display/USB expansion cable *3: Display × 1, USB 2.0 × 2 PRIMERGY BX620 S4 Server Blade User’s Guide table: Server Blade Specifications Item Functions and Specifications Keyboard/Mouse/ Display Optional (Connect to the Chassis) Internal clock precision ± 2 to 3 minutes/month Input voltage (supplied from the Chassis) Power consumption/heating value Dimensions (Unit: mm) DC 12V (During operation) / DC 5V (During standby) Max. 347W (Max. 1,250kJ/h) Max. 240W (Max. 864kJ/h) 42 × 476 × 286 (W × D × H) (1 slot occupied in BX600 S3 Chassis) Weight 7.0kg *1: In this blade server system, at least 1 unit is required. DVD-ROM drive units have a CD-R/RW function but this function cannot be used to write to CD media. *2: Connects to each keyboard/ mouse/ display connector of the CRT/KB cable (1 provided with the Chassis) that was connected to the Chassis (each Server Blade can switch and use). *3: Connect the display/ USB expansion cable (1 included with the Chassis) to the Server Blade's front connector. The specifications for this Server Blade are liable to be updated without any notice. Please be forewarned.  Support OS The supported OSes of this server are as follows. • Windows Server 2008 Standard (32-bit) • Windows Server 2008 Enterprise (32-bit) • Windows Server 2008 Standard (64-bit) • Windows Server 2008 Enterprise (64-bit) • Windows Server 2003, Standard Edition (SP1 or later) • Windows Server 2003, Enterprise Edition (SP1 or later) • Windows Server 2003, Standard x64 Edition • Windows Server 2003, Enterprise x64 Edition • Windows Server 2003 R2, Standard Edition • Windows Server 2003 R2, Enterprise Edition • Windows Server 2003 R2, Standard x64 Edition • Windows Server 2003 R2, Enterprise x64 Edition • Red Hat Enterprise Linux ES (v.4 for x86) • Red Hat Enterprise Linux ES (v.4 for EM64T) • Red Hat Enterprise Linux AS (v.4 for x86) • Red Hat Enterprise Linux AS (v.4 for EM64T) • Red Hat Enterprise Linux 5 (for x86) • Red Hat Enterprise Linux 5 (for Intel64) The latest information about the supported OS  For the latest information such as notes on supported OS not described in this manual, refer to the Fujitsu PRIMERGY website (http://primergy.fujitsu.com). 263 Appendix B Specifications for Internal Options This section explains the specifications and packaged items of internal options for the Server Blade. When you have bought an internal option as a standard option, check the contents of each optional package before use. Should it happen that items are missing, contact an office listed in the "Contact Information" of "Start Guide". B.1 CPU Specifications  Package • CPU (1) • Heat sink (1)  Specifications  Dual core processor table: CPU Specifications (Dual Core Processor) Item Functions and Specifications Product name Processor Xeon E5205 (1.86GHz/6MB) Product ID Processor Xeon X5260 (3.33GHz/6MB) PG-FG43G PG-FG43H Number of core 2 Clock frequency 1.86GHz 3.33GHz Internal secondary cache size 6MB Front side bus 1066MHz 1333MHz  Quad core processor table: CPU Specifications (Quad Core Processor) Item Product name Product ID Functions and Specifications Processor Xeon E5405 (2GHz/12MB) Processor Xeon E5420 (2.5GHz/12MB) PG-FG43J PG-FG43K Number of core Clock frequency Internal secondary cache size Front side bus 264 Processor Xeon X5460 (3.16GHz/12MB) Processor Xeon L5410 (2.33GHz/12MB) PG-FG43L PG-FG43P 3.16GHz 2.33GHz 4 2GHz 2.5GHz 12MB 1333MHz PRIMERGY BX620 S4 Server Blade User’s Guide B.2 Memory Specifications  Package • RAM modules (2)  Specifications table: Memory Specifications Item Functions and Specifications Product name Memory Module-1GB Memory Module-2GB Memory Module-4GB Product ID PG-RM1CJ PG-RM2CJ PG-RM4CJ PG-RM8CJ Component 512MB DDR2 667 FBD ×2 1GB DDR2 667 FBD ×2 2GB DDR2 667 FBD ×2 4GB DDR2 667 FBD ×2 1GB 2GB 4GB 8GB Capacity Clock frequency 667MHz Number of pins 240 B.3 Memory Module-8GB Internal Hard Disk Unit Specifications  Package • Internal hard disk unit (1)  Specifications table: Internal Hard Disk Unit Specifications Item Product name Product ID Functions and Specifications HDD SAS 10k 73GB hot plug 2.5inch HDD SAS 15k 73GB hot plug 2.5inch PG-HDD41B PG-HDD75B PG-HDD71B Interface Serial Attached SCSI (SAS) Storage media Memory capacity *1 HDD SAS 10k 147GB hot plug 2.5inch 2.5-inch hard disk unit 73.4GB 146.8GB Maximum data transfer speed Average latency speed Rpm Dimension (unit: mm) *2 Weight *1: *2: 73.4GB 3Gbit/s 3.0ms 2.0ms 10,025rpm 15,000rpm 70.1 × 100.45 × 15.0 (W × D × H) 0.22kg The value indicates memory capacity of the formatted hard disk (1GB = 10003 bytes). Hot plug carrier is not included. 265 Appendix B.4 Expansion Card Slot Module Specifications  Package • Expansion card slot module (1)  Specifications table: Expansion card slot module specifications Item Contents Product name Product ID PCI slot Dimension (unit: mm) Weight 266 Expansion Card Slot Module PG-CS103 PG-CS104 PCI-X (64-bit 133MHz) × 1 PCI-Express (x4) × 1 40 × 200 × 85 (W × D × H) Approx. 260 g PRIMERGY BX620 S4 Server Blade User’s Guide C External Floppy Disk Drive (USB) Notes on Usage The section explains notes on the usage of USB connected floppy disk drive.  Notes on floppy disk drive recognition at server startup If the floppy disk drive (USB), with a floppy disk inserted, is not connected at server startup, BIOS cannot recognize the floppy disk drive (USB). When installing Windows/Linux, or when using Windows Server 2003 Automatic System Recovery (ASR), make sure to connect the floppy disk drive (USB) with a floppy disk inserted before server startup.  Notes on floppy disk media exchange recognition when installing windows manually and at system recovery When performing system recovery using Windows Server 2003 Automatic System Recovery (ASR), also when installing Windows manually, system recovery/installation might not be performed properly. This is caused by the device driver being unreadable due to recognition failure of the floppy disk media replacement. After pressing the [Enter] key in accordance with the procedures on the screen, if the floppy disk access LED on the floppy disk drive (USB) does not turn on and the floppy disk is not accessed, follow the procedures below. 1 Eject the floppy disk and wait for 2 seconds or longer, then press the [Enter] key several times. 2 Insert the floppy disk and wait for 2 seconds or longer, then press the [Enter] key. If the floppy disk cannot be accessed, perform the procedures above again. 267 Appendix D About Switch Blade (PG-SW107) Connection Explanation about connecting this Server Blade's onboard LAN to BX600 Switch Blade (PG-SW107) and LAN number relation. table: Relation of connection when installing a Switch Blade (PG-SW107) Network blade Slot Port Server blade slot LAN number Physical Web-UI CLI BIOS NET1 1 1 No.1 NIC1 LAN1 NET2 1 2 No.2 NIC2 LAN2 NET1 2 3 No.3 NIC3 LAN3 1 NET2 2 4 No.4 NIC4 LAN4 NET1 3 5 No.5 NIC5 LAN5 NET2 3 6 No.6 NIC6 LAN6 NET1 4 1 No.1 NIC1 LAN1 NET2 4 2 No.2 NIC2 LAN2 NET1 5 3 No.3 NIC3 LAN3 2 NET2 5 4 No.4 NIC4 LAN4 NET1 6 5 No.5 NIC5 LAN5 NET2 6 6 No.6 NIC6 LAN6 NET1 7 1 No.1 NIC1 LAN1 NET2 7 2 No.2 NIC2 LAN2 NET1 8 3 No.3 NIC3 LAN3 3 NET2 8 4 No.4 NIC4 LAN4 NET1 9 5 No.5 NIC5 LAN5 NET2 9 6 No.6 NIC6 LAN6 NET1 10 1 No.1 NIC1 LAN1 NET2 10 2 No.2 NIC2 LAN2 NET1 11 3 No.3 NIC3 LAN3 4 NET2 11 4 No.4 NIC4 LAN4 NET1 12 5 No.5 NIC5 LAN5 NET2 12 6 No.6 NIC6 LAN6 NET1 13 1 No.1 NIC1 LAN1 NET2 13 2 No.2 NIC2 LAN2 NET1 14 3 No.3 NIC3 LAN3 5 268 NET2 14 4 No.4 NIC4 LAN4 NET1 15 5 No.5 NIC5 LAN5 NET2 15 6 No.6 NIC6 LAN6 MAC Address Small ↑ ↓ Big Small ↑ ↓ Big Small ↑ ↓ Big Small ↑ ↓ Big Small ↑ ↓ Big PRIMERGY BX620 S4 Server Blade User’s Guide table: Relation of connection when installing a Switch Blade (PG-SW107) Network blade Slot Port Server blade slot LAN number Physical Web-UI CLI BIOS NET1 16 1 No.1 NIC1 LAN1 NET2 16 2 No.2 NIC2 LAN2 NET1 17 3 No.3 NIC3 LAN3 NET2 17 4 No.4 NIC4 LAN4 NET1 18 5 No.5 NIC5 LAN5 NET2 18 6 No.6 NIC6 LAN6 NET1 19 1 No.1 NIC1 LAN1 NET2 19 2 No.2 NIC2 LAN2 NET1 20 3 No.3 NIC3 LAN3 6 7 NET2 20 4 No.4 NIC4 LAN4 NET1 21 5 No.5 NIC5 LAN5 NET2 21 6 No.6 NIC6 LAN6 NET1 22 1 No.1 NIC1 LAN1 NET2 22 2 No.2 NIC2 LAN2 NET1 23 3 No.3 NIC3 LAN3 NET2 23 4 No.4 NIC4 LAN4 NET1 24 5 No.5 NIC5 LAN5 NET2 24 6 No.6 NIC6 LAN6 NET1 25 1 No.1 NIC1 LAN1 NET2 25 2 No.2 NIC2 LAN2 NET1 26 3 No.3 NIC3 LAN3 8 9 NET2 26 4 No.4 NIC4 LAN4 NET1 27 5 No.5 NIC5 LAN5 NET2 27 6 No.6 NIC6 LAN6 NET1 28 1 No.1 NIC1 LAN1 NET2 28 2 No.2 NIC2 LAN2 NET1 29 3 No.3 NIC3 LAN3 NET2 29 4 No.4 NIC4 LAN4 NET1 30 5 No.5 NIC5 LAN5 NET2 30 6 No.6 NIC6 LAN6 10 MAC Address Small ↑ ↓ Big Small ↑ ↓ Big Small ↑ ↓ Big Small ↑ ↓ Big Small ↑ ↓ Big 269 Appendix  This Server Blade's onboard LAN has 6 ports, the sequence depends on the OS or manner the LAN driver was installed. When planning a network, pay attention to the LAN numbers, device names in the OS, and local area connection names above. If the OS is Windows, the MAC address, device name, and local connection name can be checked with the "ipconfig /all" command in command prompt. Local area connection name Device name MAC Address 270 PRIMERGY BX620 S4 Server Blade User’s Guide E Recycling This section explains how to recycle this server.  Disposing of the server When scrapping this server, contact an office listed in the "Contact Information" of "Start Guide". This server must be disposed of as industrial waste. Furthermore, if the server is disposed of as it is, someone else may gain access to the information contained on the hard disks. It is therefore recommended that all drives be formatted before disposal. However, just formatting or deleting files may not avoid the risk that the data is restored and used for wrongful purposes. If confidential or private information is saved, in order to make it impossible to be restored, it is recommended to use third-party data wiping tools.  Disposing of used-up batteries Used-up batteries must be disposed of as industrial waste and therefore require special processing. Let a licensed industrial waste disposal company take care of disposal.  Disposing of liquid crystal displays Liquid crystal displays must be disposed of as industrial waste and therefore require special processing. Let a licensed industrial waste disposal company take care of disposal. 271 Appendix 272 PRIMERGY BX620 S4 Server Blade User’s Guide Index A D Advanced Menu . . . . . . . . . . . . . . . . . . . . 209 Application wizard Expert mode . . . . . . . . . . . . . . . . . . . . . 65 ASR&R Submenu . . . . . . . . . . . . . . . . . . . 217 Auto-run Function from CD/DVD Drives . . 117 Defective CPU Disconnection Function . . .181 Defective Memory Disconnection Function .187 DIMM . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183 Disk Manager . . . . . . . . . . . . . . . . . . . . . . . .59 Drive Letter Assignment . . . . . . . . . . . . . . .117 Driver types Windows Server 2003 . . . . . . . . . . . . . . .71 Windows Server 2003 x64 . . . . . . . . . . .71 Windows Server 2008 (32-bit/64-bit) . . . .70 DSNAP. . . . . . . . . . . . . . . . . . . . . . . . .24, 169 Installation. . . . . . . . . . . . . . . . . . . . . . .169 Usage . . . . . . . . . . . . . . . . . . . . . . . . . .169 Dual Core Intel Xeon Processor . . . . . . . . . .18 Dummy unit . . . . . . . . . . . . . . . . . . . . . . . .199 B Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 Backup cabinet . . . . . . . . . . . . . . . . . . . . . 202 BACS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Installing . . . . . . . . . . . . . . . . . . . . . . . 123 LAN driver advanced setup . . . . . . . . . 123 VLAN . . . . . . . . . . . . . . . . . . . . . . . . . 143 Baseboard . . . . . . . . . . . . . . . . . . . . . . . . . 31 BIOS Setup Utility . . . . . . . . . . . . . . . . . . . 205 How to Exit . . . . . . . . . . . . . . . . . . . . . 206 How to Start . . . . . . . . . . . . . . . . . . . . 205 Key Operations . . . . . . . . . . . . . . . . . . 206 BMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 Boot Device Priority Submenu . . . . . . . . . 225 Boot Menu . . . . . . . . . . . . . . . . . . . . . . . . 224 Boot monitoring setting . . . . . . . . . . . . . . . 167 C Cautions for manual installation . . . . . . . . . 45 Chassis connector . . . . . . . . . . . . . . . . . . . 30 Checking before OS installation . . . . . . . . . 33 Connector Display / USB extension connector . . . . 29 Connector for expansion card slot module . 31 Console Redirection Submenu . . . . . . . . . 222 Contacting Maintenance Support . . . . . . . 259 CPU Available CPUs . . . . . . . . . . . . . . . . . . 177 How to Install. . . . . . . . . . . . . . . . . . . . 178 How to Remove . . . . . . . . . . . . . . . . . 181 Installation location . . . . . . . . . . . . . . . 176 Installation Order. . . . . . . . . . . . . . . . . 176 Specifications . . . . . . . . . . . . . . . . . . . 264 CPU Configuration Submenu . . . . . . . . . . 213 CPU socket. . . . . . . . . . . . . . . . . . . . . . 30, 31 CPU Status Submenu . . . . . . . . . . . . . . . . 220 Creating a DOS Floppy Disk . . . . . . . . . . . 116 Creating Driver Disks . . . . . . . . . . . . . . . . . 70 Creating Maintenance Tools . . . . . . . . . . . 113 E Error Messages . . . . . . . . . . . . . . . . .234, 238 POST Error Messages . . . . . . . . . . . . .234 Server Management Tools Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . .236 Event logs. . . . . . . . . . . . . . . . . . . . . . . . . .240 Exit Menu . . . . . . . . . . . . . . . . . . . . . . . . . .226 Expansion board Available Expansion Boards . . . . . . . . .195 BIOS Setting with Expansion Card Installed . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201 How to Install . . . . . . . . . . . . . . . . . . . .195 How to Remove . . . . . . . . . . . . . . . . . .196 Installation location . . . . . . . . . . . . . . . .194 Expansion board active link display LED. . . .29 Expansion board slot . . . . . . . . . . . . . . .30, 31 Expansion Card Slot . . . . . . . . . . . . . . . .29, 30 Expansion card slot module Available Expansion Card Slot Module .189 Expansion cards Available Expansion Card . . . . . . . . . . .189 How to Install . . . . . . . . . . . . . . . . . . . .190 How to Remove . . . . . . . . . . . . . . . . . .193 Installation location . . . . . . . . . . . . . . . .188 Expert mode . . . . . . . . . . . . . . . . . . . . . . . . .55 F Fan monitoring . . . . . . . . . . . . . . . . . . . . . .165 H Hard disk access LED . . . . . . . . . . . . . . . . .27 Hard disk failure LED . . . . . . . . . . . . . . . . . .28 273 Hard disk status LED . . . . . . . . . . . . . . . . . . 27 High Reliability Tools . . . . . . . . . . . . . . . . . . 23 How to install . . . . . . . . . . . . . . . . . . . . . 25 How to store the BIOS Information. . . . . . . 111 HRM/server . . . . . . . . . . . . . . . . . . . . . . . . 168 I Identification label . . . . . . . . . . . . . . . . . . . 184 Installation DSNAP . . . . . . . . . . . . . . . . . . . . . . . . 169 ServerStart . . . . . . . . . . . . . . . . . . . . . . 113 ServerView. . . . . . . . . . . . . . . . . . . . . . 166 Installation Partition Size . . . . . . . . . . . . . . . 42 Installing the Fibre Channel Driver . . . . . . . . 94 Installing the LAN Driver Error window after installation. . . . . . . . 239 Windows Server 2003 . . . . . . . . . . . . . . 92 Windows Server 2003 x64 . . . . . . . . . . . 91 Windows Server 2008 (32-bit) . . . . . . . . 89 Windows Server 2008 (64-bit) . . . . . . . . 90 Intel® PROSet . . . . . . . . . . . . . . . . . . . . . . 151 Creating a team . . . . . . . . . . . . . . . . . . 154 Local Address Setting . . . . . . . . . . . . . 161 Notes on Referring to Help Topics . . . . 152 Teaming . . . . . . . . . . . . . . . . . . . . . . . . 153 VLAN . . . . . . . . . . . . . . . . . . . . . . . . . . 158 Internal Hard Disk Unit Available Internal Hard Disk Units . . . . 198 How to Install . . . . . . . . . . . . . . . . . . . . 199 How to Remove . . . . . . . . . . . . . . . . . . 200 Installation location . . . . . . . . . . . . . . . . 198 Replacing the failed unit . . . . . . . . . . . . 200 Specifications . . . . . . . . . . . . . . . . . . . . 265 I/O expansion board port . . . . . . . . . . . . . . . 30 K KVM select LED. . . . . . . . . . . . . . . . . . . . . . 28 KVM select switch . . . . . . . . . . . . . . . . . . . . 29 L LAN active link display LED . . . . . . . . . . . . . 29 LAN Driver Advanced Setup . . . . . . . . . . . 151 Intel® PROSet . . . . . . . . . . . . . . . . . . . 151 M Main Menu (BIOS) . . . . . . . . . . . . . . . . . . . 208 Manual installation Linux . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Windows Server 2003 . . . . . . . . . . . . . . 86 Windows Server 2003 x64 . . . . . . . . . . . 83 Windows Server 2008 (Full) . . . . . . . . . . 76 Windows Server 2008 (Server Core) . . . 79 274 Memory Dump . . . . . . . . . . . . . . . . . . 100, 240 Memory Dump File Setting . . . . . . . . . . . . 101 Memory Dump Setting . . . . . . . . . . . . . . . . 100 Memory modules Available Memory Modules . . . . . . . . . 183 How to Install . . . . . . . . . . . . . . . . . . . . 186 How to Remove . . . . . . . . . . . . . . . . . . 186 Identifying . . . . . . . . . . . . . . . . . . . . . . 184 Installation location. . . . . . . . . . . . . . . . 183 Specifications . . . . . . . . . . . . . . . . . . . . 265 Memory monitoring . . . . . . . . . . . . . . . . . . 165 Memory slots . . . . . . . . . . . . . . . . . . . . . 30, 31 Memory Status Submenu. . . . . . . . . . . . . . 221 Multiple LAN adapter configuration . . . . . . . 43 Adapter numbers . . . . . . . . . . . . . . . . . . 44 N NMI function . . . . . . . . . . . . . . . . . . . . . . . . 29 Notes on a multiple LAN adapter configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Notes on UPS . . . . . . . . . . . . . . . . . . . . . . 118 O OS installation wizard Expert mode . . . . . . . . . . . . . . . . . . . . . 60 P Paging File Setting. . . . . . . . . . . . . . . . . . . 103 Password Administrator Password . . . . . . . . . . . . 248 Change . . . . . . . . . . . . . . . . . . . . . . . . 249 Delete . . . . . . . . . . . . . . . . . . . . . . . . . 249 Setting . . . . . . . . . . . . . . . . . . . . . . . . . 249 User Password. . . . . . . . . . . . . . . . . . . 248 PCI Configuration Submenu . . . . . . . . . . . 212 PCI-Express . . . . . . . . . . . . . . . . . . . . . . . . 18 PCI-X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Peripheral Configuration Submenu . . . . . . 210 POST . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 Error Messages . . . . . . . . . . . . . . . . . . 234 Power supply monitoring . . . . . . . . . . . . . . 166 Precautions on installation . . . . . . . . . . . . . . 42 Q Quad Core Intel Xeon Processor . . . . . . . . . 18 R RAID Configuration Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 RAID error monitoring . . . . . . . . . . . . . . . . 165 RAID Management Tool. . . . . . . . . . . . 24, 164 Recovering the BIOS Information . . . . . . . 112 PRIMERGY BX620 S4 Server Blade User’s Guide Release latch . . . . . . . . . . . . . . . . . . . . . . . 27 Restoring the system Windows Server 2003 . . . . . . . . . . . . . 256 Windows Server 2008 . . . . . . . . . . . . . 254 S SAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 SAS connector . . . . . . . . . . . . . . . . . . . . . . 31 Security Against unauthorized use . . . . . . . . . . 248 Hardware . . . . . . . . . . . . . . . . . . . . . . 248 When disposing of the server . . . . . . . 250 Security Menu. . . . . . . . . . . . . . . . . . . . . . 214 Selecting the installation method. . . . . . . . . 39 Server blade power LED. . . . . . . . . . . . . . . 28 Server blade power switch . . . . . . . . . . . . . 28 Server Management Tools . . . . . . . . 110, 243 Error Messages. . . . . . . . . . . . . . . . . . 236 How to Exit . . . . . . . . . . . . . . . . . . . . . 245 How to Start . . . . . . . . . . . . . . . . . . . . 244 Server Menu . . . . . . . . . . . . . . . . . . . . . . . 216 Server Monitoring Tool . . . . . . . . . . . . 23, 165 Installation . . . . . . . . . . . . . . . . . . . . . . 166 Server Specifications . . . . . . . . . . . . . . . . 262 ServerStart . . . . . . . . . . . . . . . . . . . . . . . . . 20 Cautions . . . . . . . . . . . . . . . . . . . . . . . . 43 Features . . . . . . . . . . . . . . . . . . . . . . . . 20 Installation . . . . . . . . . . . . . . . . . . . . . . 113 Supported expansion cards. . . . . . . . . . 45 Uninstallation. . . . . . . . . . . . . . . . . . . . 115 ServerView . . . . . . . . . . . . . . . . . . 23, 24, 165 Installation . . . . . . . . . . . . . . . . . . . . . . 166 Settings Required Before Operating the Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 SNMP service . . . . . . . . . . . . . . . . . . . . . . 241 Solving problems . . . . . . . . . . . . . . . . . . . 169 Specifications for Internal Options . . . . . . . 264 Switch block . . . . . . . . . . . . . . . . . . . . . . . . 31 Setting. . . . . . . . . . . . . . . . . . . . . . . . . 204 System diagnosis support tools. . . . . . . . . . 24 System event log . . . . . . . . . . . . . . . . . . . 243 Deleting. . . . . . . . . . . . . . . . . . . . . . . . 247 Saving. . . . . . . . . . . . . . . . . . . . . . . . . 246 Viewing . . . . . . . . . . . . . . . . . . . . . . . . 246 System Information Submenu. . . . . . . . . . 223 System Recovery Disk . . . . . . . . . . . . . . . 107 Types of internal options . . . . . . . . . . . . . . .172 U Uninstallation ServerStart . . . . . . . . . . . . . . . . . . . . . .115 USB Configuration submenu . . . . . . . . . . .211 V Voltage monitoring . . . . . . . . . . . . . . . . . . .166 Numeric 2.5-inch storage bay . . . . . . . . . . . . . . . .27, 30 T Temperature monitoring . . . . . . . . . . . . . . Top cover How to Attach . . . . . . . . . . . . . . . . . . . How to Remove . . . . . . . . . . . . . . . . . Troubleshooting Hardware . . . . . . . . . . . . . . . . . . . . . . 166 175 174 229 275 PRIMERGY BX620 S4 Server Blade User's Guide B7FH-5591-01ENZ0-00 Issued in Issued by August, 2008 FUJITSU LIMITED • The contents may be revised without prior notice. • Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. • No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.