Preview only show first 10 pages with watermark. For full document please download

Prisma Gigabit Ethernet Media Converter Module Installation

   EMBED


Share

Transcript

Prisma Gigabit Ethernet Media Converter Module Installation Instructions Overview Purpose These installation instructions provide product information and instructions for installing the Prisma® Gigabit Ethernet Media Converter module. Introduction The SNMP-manageable Prisma Gigabit Ethernet Media Converter module (for simplicity in this document called “module”) provides a single conversion between 1000Base-T twisted pair and 1000Base-SX/LX fiber cabling. Each module includes one RJ-45 connector and one pair of SC fiber optic connectors. The module installs in modular, SNMP-manageable Prisma MediaCenter™ series of chassis as well as the unmanaged Prisma MediaCPE™ chassis series. The module is also available in a single-strand fiber version that allows two wavelengths to share one fiber strand. Full-Duplex data travels on different wavelengths (1310 nm and 1550 nm), doubling the capacity of fiber. It includes one RJ-45 connector and one SC fiber connector. Note: All modules, including 1300 multi-mode and 1310 single-mode (TX/LX), 850 nm multi-mode fiber (TX/SX), single-strand versions (TX/SSLX) and those with CDWM, will be referred to as such throughout this installation guide except where differences need to be indicated. Continued on next page Overview, Continued Qualified Personnel Only appropriately qualified and trained personnel should install, operate, maintain, and service this product. WARNING: Allow only qualified personnel to install, operate, maintain, and service this product. Otherwise, personal injury or equipment damage may occur. In These Installation Instructions These installation instructions contain the following topics. Topic 2 See Page Important Safety Instructions 3 Laser Safety 5 Configuration Instructions 8 About LinkLoss and FiberAlert 10 Additional Gigabit Features 12 Installing the Prisma Gigabit Ethernet Media Converter Module 14 Fiber Optic Cleaning Guidelines 15 LED Operation 17 Installation Troubleshooting 19 For Information 20 Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B Important Safety Instructions Read and Retain Instructions Carefully read all safety and operating instructions before operating this equipment, and retain them for future reference. Follow Instructions and Heed Warnings Follow all operating and use instructions. Pay attention to all warnings and cautions in the operating instructions, as well as those that are affixed to this equipment. Electrostatic Discharge Electrostatic discharge (ESD) results from the static electricity buildup on the human body and other objects. This static discharge can degrade components and cause failures. Take the following precautions against electrostatic discharge: • Use an anti-static bench mat and a wrist strap or ankle strap designed to safely ground ESD potentials through a resistive element. • Keep components in their anti-static packaging until installed. • Avoid touching electronic components when installing a module. EMC Where this equipment is subject to USA FCC and/or Industry Canada rules, the following statements apply: FCC Statement for Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Continued on next page 4007998 Rev B Prisma Gigabit Ethernet Media Converter Module Installation Instructions 3 Important Safety Instructions, Continued This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Industry Canada – Industrie Canadienne Statement This apparatus complies with Canadian ICES-003. Cet appareil est confome à la norme NMB-003 du Canada. Modifications This equipment has been designed and tested to comply with applicable safety, laser safety, and EMC regulations, codes, and standards to ensure safe operation in its intended environment. Do not make modifications to this equipment. Any changes or modifications could void the user’s authority to operate this equipment. Modifications have the potential to degrade the level of protection built into this equipment, putting people and property at risk of injury or damage. Those persons making any modifications expose themselves to the penalties arising from proven non-compliance with regulatory requirements and to civil litigation for compensation in respect of consequential damages or injury. 4 Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B Laser Safety Introduction This equipment contains an infrared laser that transmits intensity-modulated light and emits invisible radiation. Warning: Radiation WARNINGS: • Avoid personal injury! Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous radiation exposure. • Avoid personal injury! The laser light source on this equipment emits invisible laser radiation. Avoid direct exposure to the laser light source. • Do not apply power to this equipment if the fiber is unmated or unterminated. • Do not stare into an unmated fiber or at any mirror-like surface that could reflect light that is emitted from an unterminated fiber. • Do not view an activated fiber with optical instruments (e.g., eye loupes, magnifiers, microscopes). • Use safety-approved optical fiber cable to maintain compliance with applicable laser safety requirements. Warning: Fiber Optic Cables WARNING: Avoid personal injury! Qualified service personnel may only perform the procedures in this document. Wear safety glasses and use extreme caution when handling fiber optic cables, particularly during splicing or terminating operations. The thin glass fiber core at the center of the cable is fragile when exposed by the removal of cladding and buffer material. It easily fragments into glass splinters. Using tweezers, place splinters immediately in a sealed waste container and dispose of them safely in accordance with local regulations. Continued on next page 4007998 Rev B Prisma Gigabit Ethernet Media Converter Module Installation Instructions 5 Laser Safety, Continued Safe Operation For Software Controlling Optical Transmission Equipment If this document discusses software, the software described is used to monitor and/or control ours and other vendors’ electrical and optical equipment designed to transmit video, voice, or data signals. Certain safety precautions should be observed when operating equipment of this nature. For equipment specific safety requirements, refer to the appropriate section of the equipment documentation. For safe operation of this software, refer to the following warnings. WARNINGS: • Ensure that all optical connections are complete or terminated before using this equipment to remotely control a laser device. An optical or laser device can pose a hazard to remotely located personnel when operated without their knowledge. • Allow only personnel trained in laser safety to operate this software. Otherwise, injuries to personnel may occur. • Restrict access of this software to authorized personnel only. • Install this software in equipment that is located in a restricted access area. Laser Safety Information This laser based multi-mode transceiver is an IEC 60825-1 Amend. 2 Class 1 laser product. It complies with FDA performance standards (21 CFR 1040.10 and 1040.11) for laser products except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001. Note: All adjustments have been made at the factory prior to shipment of the module. No maintenance or alteration of this device is required. No adjustments or controls provided. Class 1 Laser Product Avoid possible exposure to hazardous levels of invisible laser radiation; do not view laser aperture. Continued on next page 6 Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B Laser Safety, Continued Product Specific Laser Information The following illustration displays the location of the laser apertures on this module’s front panel. Laser Aperture The following labels are on the module. Class 1 Laser product, Luokan 1 Laserlaite, Laser Klasse 1, Appareil A'Laser de Classe 1 4007998 Rev B Prisma Gigabit Ethernet Media Converter Module Installation Instructions 7 Configuration Instructions Introduction The Prisma Gigabit Ethernet Media Converter modules have user-configurable features. Refer to the table in Switch Configuration Table later in these instructions for available features. Instructions for configuring both managed (via an SNMP-compatible management application like PrismaView™ ) and unmanaged modules follow. Managed Modules To manage one or more modules, an SNMP agent must be present in the chassis: some chassis have embedded management; other chassis use an SNMP management module. To configure managed modules, install the module first. Refer to Installing the Prisma Gigabit Ethernet Media Converter Module later in these instructions for installation instructions. Then, configure using the management software. Refer to the PrismaView software for Media Converters online help file for more information and assistance. Note: Management software will override hardware settings (e.g., jumper, switch, etc.), so you MUST configure a module that will be managed via the software. Until you configure a managed module via the software, the module (and its LEDs) may not work properly. Continued on next page 8 Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B Configuration Instructions, Continued Unmanaged Modules S1 ON 1 2 5 3 4 8 FiberAlert FX Auto-Negotiation Set at Factory DO NOT CHANGE TX LinkLoss 7 } } } } } } Forced/Preferred Master/Slave Mode 6 DISABLE ENABLE Before installing the module, configure the modules for desired features. The diagram below shows the switch location on the module. The chart below states the available features and settings for the module. After configuring the switch for the desired settings, install the module and connect the appropriate cables. Refer to Installing the Prisma Gigabit Ethernet Media Converter Module later in these instructions for installation instructions. Switch Configuration Table Feature Switch Default Forced/Preferred* DIP Switch 1 on S1 ON Master/Slave* DIP Switch 2 on S1 ON TX LinkLoss DIP Switch 3 on S1 OFF FiberAlert DIP Switch 4 on S1 OFF FX Auto-Negotiation DIP Switch 5 on S1 OFF * These features are hardware configurable ONLY. Please make sure DIP switches are set appropriately for your configuration requirements. 4007998 Rev B Prisma Gigabit Ethernet Media Converter Module Installation Instructions 9 About LinkLoss and FiberAlert Introduction The Prisma Gigabit Ethernet Media Converter modules include the troubleshooting features FiberAlert and TX LinkLoss that help locate "silent failures" on your network. It is vital to understand how FiberAlert and LinkLoss work, and how they will react in your network configuration, before attempting to install the module(s). CAUTION: Installing modules without understanding the effects of FiberAlert/LinkLoss can cause perfectly functioning units to appear flawed or even dead About Link Integrity During normal operation, link integrity pulses are transmitted by all point-to-point Ethernet devices. When a media converter receives valid link pulses, it knows that the device to which it is connected is up and sending pulses, and that the copper or fiber cable coming from that device is intact. The appropriate “LNK” (link) LED is lit to indicate this. The media converter also sends out link pulses from its copper and fiber transmitters, but normally has no way of knowing whether the cable to the other device is intact and the link pulses are reaching the other end. The combination of FiberAlert and LinkLoss allows this information to be obtained, even when physical access to a remote device (and its link integrity LED) is not available. What Is TX LinkLoss? TX LinkLoss is a troubleshooting feature. When a fault occurs on the twisted pair segment of a conversion, TX LinkLoss detects the fault and passes this information to the fiber segment. If a media converter is not receiving a twisted pair link, TX LinkLoss disables the transmitter on the media converter's fiber port. This results in a loss of link on the device connected to the fiber port. Continued on next page 10 Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B About LinkLoss and FiberAlert, Continued What Is FiberAlert? FiberAlert minimizes the problems associated with the loss of one strand of fiber. If a strand is unavailable, the device at the receiver end notes the loss of link. The device then stops transmitting data and the link signal until a signal or link pulse is received. The result is that the link LED on BOTH sides of the fiber connection will go out indicating a fault somewhere in the fiber loop. Using FiberAlert, a local site administrator is notified of a fault and can quickly determine where a cable fault is located. Note: Enable FiberAlert on ONE side of a media conversion only; enabling it on both sides would keep both transmitters off indefinitely! Using FiberAlert and LinkLoss Modules ship from the factory with troubleshooting features disabled. To enable/disable these features, please refer to the Configuration Instructions earlier in these instructions, or the product’s help file. LinkLoss/FiberAlert Comparison Table The following table provides an overview of the troubleshooting features, their functionality and the recommended settings for a pair of media converters in a typical central/main site to remote site application. Feature Fault Location Disabled LEDs Enable At: TX LinkLoss Twisted Pair Fiber Remote Site Only FiberAlert Fiber Fiber Remote Site Only If you are unsure of how best to implement these features in your configuration, contact technical support. Refer to For Information later in these instructions for contact information. 4007998 Rev B Prisma Gigabit Ethernet Media Converter Module Installation Instructions 11 Additional Gigabit Features Master/Slave Mode This Master/Slave mode feature determines which clock will be used between the Prisma Gigabit Ethernet Media Converter module and the device it is connected to (a switch, NIC, or another Prisma Gigabit Ethernet Media Converter module, etc.). Slave mode is the default setting. In Slave mode, the module receives and uses the clock of the connected device. Master mode uses the module's clock. The Master/Slave mode is only valid for the twisted pair link. This Master/Slave mode feature is hardware configurable ONLY. Preferred/Forced Mode In addition to Master/Slave modes, the module also includes Preferred/Forced modes for Master/Slave negotiation. • Preferred mode helps determine whether the module should act as a Master or Slave. • Forced Mode should typically only be used when connecting to some legacy switches, or when there is difficulty establishing a link. This Preferred/Forced mode feature is hardware configurable ONLY. Since most switches today typically function as Masters, we recommend configuring the modules as indicated in the following chart. DIP Switch Setting S1-1 ON (Preferred) S1-2 ON (Slave) FX Negotiation on the Prisma Gigabit Module The modules include the FX Negotiation feature that negotiates duplex mode. The default for this feature is disabled. You must enable or disable this feature on both ends of the connection or you may have difficulty establishing a link. If the device you are connecting to the module does not support this auto-negotiation feature, disabling the feature on the module forces the link up. Continued on next page 12 Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B Additional Gigabit Features, Continued The following table shows various configurations and the resulting link status: FX Auto-Negotiation on a Switch or Prisma Gigabit 4007998 Rev B FX Auto-Negotiation on Prisma Gigabit Link Status Prisma Gigabit - OFF OFF Link Prisma Gigabit - ON ON Link Prisma Gigabit - OFF ON No Link Switch - ON OFF No Link Switch - ON ON Link Switch - OFF OFF Link Switch - OFF ON Link Prisma Gigabit Ethernet Media Converter Module Installation Instructions 13 Installing the Prisma Gigabit Ethernet Media Converter Module Introduction Prisma series modules install in an SNMP-manageable Prisma MediaCenter chassis or in Prisma MediaCPE chassis. Installing the Module Follow these steps to install a module. 1. Remove the blank bracket covering the slot where the module is to be installed by removing the screws on the outside edges of the bracket. 2. Slide the module into the chassis, via the card guides, until the module is seated securely in the connector. 3. Secure the module to the chassis by tightening the captive screw. Note: Save any “blanks” removed during installation for future use should configuration requirements change. Installation Tip: When testing, we recommend testing modules first in an unmanaged environment. To do this, disable management (turn management off or remove the management module from the chassis), follow the unmanaged configuration instructions, then install the unit, connect the cables and test the LEDs. When finished, re-activate management and configure the unit via the software. Installation Tip: Since single-strand fiber products use optics that transmit and receive on two different wavelengths, you must deploy single-strand fiber products in pairs, or connect two compatible single-strand fiber products. Twisted Pair Crossover/Pass-Through Connections The modules support both crossover and straight-through Cat5 twisted pair cabling types of connections with AutoCross, a feature that automatically selects between the two, depending on the connected device. 14 Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B Fiber Optic Cleaning Guidelines Optical Connector Cleaning Overview Cleaning fiber-optic connectors can help prevent interconnect problems and therefore aid system performance. When optical connectors are disconnected and reconnected, the fiber surface can become dirty or scratched. The goal of cleaning the fiber optic connectors is to remove all dust and contaminants without leaving any residue. Required Equipment The following equipment is required to clean the ends of fiber-optic connectors. • CLETOP or OPTIPOP ferrule cleaner (CLETOP Type A for SC, Type B for LC) • Compressed air (also called “canned air”) • Lint-free wipes moistened with optical-grade (99%) isopropyl alcohol • Bulkhead swabs for LC or SC type connectors (choose appropriate type) • Optical connector scope Tips for Optimal Fiber-Optic Connector Performance Follow these guidelines to ensure optimal connector performance. • Do not connect or disconnect optical connectors while optical power is present. • Always use compressed air before cleaning the fiber-optic connectors. • Always use end caps on connectors when they are not in use. • Always use compressed air to clean the end caps. • If you have any degraded signal problems, clean the fiber-optic connector. • Advance a clean portion of the ferrule cleaner reel for each cleaning. • Turn off optical power before making or breaking optical connections in order to avoid microscopic damage to fiber mating surfaces. Continued on next page 4007998 Rev B Prisma Gigabit Ethernet Media Converter Module Installation Instructions 15 Fiber Optic Cleaning Guidelines, Continued Cleaning Optical Connectors WARNING: Avoid personal injury! Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous radiation exposure Avoid personal injury! The laser light source on this equipment emits invisible laser radiation. Avoid direct exposure to the laser light source. Avoid personal injury! Viewing the laser output with optical instruments (such as eye loupes, magnifiers, or microscopes) may pose an eye hazard. • Do not apply power to this equipment if the fiber is unmated or unterminated. • Do not stare into an unmated fiber or at any mirror-like surface that could reflect light that is emitted from an unterminated fiber. • Do not view an activated fiber with optical instruments (e.g., eye loupes, magnifiers, microscopes). • Use safety-approved optical fiber cable to maintain compliance with applicable laser safety requirements. Important: Ensure that no optical power is present prior to this procedure. 1. Turn optical power off to the connector. 2. Using an optical connector scope, inspect the connector for scratches, burns, or other signs of damage. Note: If the connector is damaged, replace the jumper. 3. If the connector requires cleaning, swipe it across the face of the appropriate ferrule cleaner several times. Result: This will remove dust and some films. Note: You may hear a slight "squeak" while cleaning the connector, indicating that it is clean. 16 4. Inspect the connector again. If the connector requires further cleaning, clean it using 99% isopropyl alcohol and a lint free wipe. 5. Swipe the connector across the face of the appropriate ferrule cleaner several more times to remove any film left by the alcohol. 6. Repeat all the steps above as needed until the connector is clean. Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B LED Operation Prisma Gigabit Ethernet Media Converter Module Front Panel The following illustration shows the Prisma Gigabit Ethernet Media Converter module front panel. Prisma Gigabit Ethernet Media Converter Module Front Panel Components The Prisma Gigabit Ethernet Media Converter module features diagnostic LEDs that provide information on features and ports. LED LNK/ACT Description • Glows green when a twisted pair link is established. • Blinks green when data is detected on the port. • Located on RJ-45 connector. Continued on next page 4007998 Rev B Prisma Gigabit Ethernet Media Converter Module Installation Instructions 17 LED Operation, Continued LED Description • Glows amber when port is operating in Full-Duplex mode. FDX • Located on RJ-45 connector. 18 FA Glows green when FiberAlert is enabled. TX LL Glows green when TX LinkLoss is enabled on the port. LNK Glows green when a fiber link is established. MASTER Glows amber when operating as a Master. Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B Installation Troubleshooting Troubleshooting • During installation, first test the fiber and twisted pair connections with all troubleshooting features disabled, then enable these features, if desired, just before final installation. This will reduce the features’ interference with testing. • When working with units where the features cannot be disabled, you must establish BOTH your twisted pair and fiber connections before the link LEDs will illuminate. • If using a high powered device (which is designed for long distance installations) for a short distance installation, the fiber transmitters may overdrive the receivers and cause data loss. If this is the case, you may need to add an optical attenuator to your connection. 4007998 Rev B Prisma Gigabit Ethernet Media Converter Module Installation Instructions 19 For Information Support Telephone Numbers This table lists the Technical Support and Customer Service numbers for your area. Region Centers North America Cisco Services Atlanta, Georgia United States Telephone and Fax Numbers For Technical Support, call: ƒ Toll-free: 1-800-722-2009 ƒ Local: 678-277-1120 (Press 2 at the prompt) For Customer Service or to request an RMA number, call: ƒ ƒ ƒ ƒ Europe, Middle East, Africa Belgium Toll-free: 1-800-722-2009 Local: 678-277-1120 (Press 3 at the prompt) Fax: 770-236-5477 E-mail: [email protected] For Technical Support, call: ƒ Telephone: 32-56-445-197 or 32-56-445-155 ƒ Fax: 32-56-445-061 For Customer Service or to request an RMA number, call: Japan Japan Korea Korea China (mainland) China All other Asia-Pacific countries & Australia Brazil Hong Kong Brazil ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ Telephone: 32-56-445-444 Fax: 32-56-445-051 E-mail: [email protected] Telephone: 81-3-5908-2153 or +81-3-5908-2154 Fax: 81-3-5908-2155 E-mail: [email protected] Telephone: 82-2-3429-8800 Fax: 82-2-3452-9748 E-mail: [email protected] Telephone: 86-21-2401-4433 Fax: 86-21-2401-4455 E-mail: [email protected] Telephone: 852-2588-4746 Fax: 852-2588-3139 E-mail: [email protected] For Technical Support, call: ƒ Telephone: 55-11-3845-9154 ext 230 ƒ Fax: 55-11-3845-2514 For Customer Service or to request an RMA number, call: ƒ Telephone: 55-11-3845-9154, ext 109 ƒ Fax: 55-11-3845-2514 ƒ E-mail: [email protected] Mexico, Central America, Caribbean Mexico All other Latin America countries Argentina For Technical Support, call: ƒ Telephone: 52-3515152599 ƒ Fax: 52-3515152599 For Customer Service or to request an RMA number, call: ƒ Telephone: 52-55-50-81-8425 ƒ Fax: 52-55-52-61-0893 ƒ E-mail: [email protected] For Technical Support, call: ƒ Telephone: 54-23-20-403340 ext 109 ƒ Fax: 54-23-20-403340 ext 103 For Customer Service or to request an RMA number, call: ƒ Telephone: 770-236-5662 ƒ Fax: 770-236-5888 ƒ E-mail: [email protected] 20 Prisma Gigabit Ethernet Media Converter Module Installation Instructions 4007998 Rev B 4007998 Rev B Prisma Gigabit Ethernet Media Converter Module Installation Instructions 21 5030 Sugarloaf Parkway, Box 465447 Lawrenceville, GA 30042 678.277.1000 Cisco, Cisco Systems, the Cisco logo, the Cisco Systems logo, Prisma, MediaCenter, PrismaView, and MediaCPE are registered trademarks or trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. Product and service availability are subject to change without notice. © 2009 Cisco Systems, Inc. All rights reserved. Printed in United States of America February 2009 Part Number 4007998 Rev B