Transcript
2 -Wire Intercom System PRO591/592 User Manual
PRO591
PRO592
3529,6,216(&85,7<352'8&76 5(9
CONTENTS 1.Parts and Functions............................................................................................. 1 2.Terminal Descriptions........................................................................................... 1 3.Specifications....................................................................................................... 2 4.Mounting............................................................................................................... 2 4.1 Mounting Without Rainy Cover....................................................................... 2 4.2 Mounting With Rainy Cover............................................................................ 3 4.3 Placing Name Label....................................................................................... 3 4.4 Adjusting Camera Angle................................................................................. 4 5.System Wiring and Connections.......................................................................... 4 5.1 Basic Connection........................................................................................... 4 5.2 Electric Lock Connection................................................................................ 5 5.2.1 Door Lock Controlled with Internal Power............................................. 5 5.2.2 Door Lock Controlled with Dry Contact................................................. 5 5.2.3 How to setup the unlock parameter in Monitor....................................... 6 5.3 Multi Doorstations Connection....................................................................... 7 5.4 Multi Monitors Connection.............................................................................. 8 5.4.1 Basic IN-OUT Wiring Mode.................................................................. 8 5.4.2 With PRODBC-4 Wiring Mode.............................................................. 9 6.Setup.................................................................................................................... 10 6.1 DIP Switches Settings of Doorstation............................................................. 10 6.2 DIP Switches Settings of Monitor................................................................... 10 6.3 Notices........................................................................................................... 12 7.Cables Requirements........................................................................................... 13
1.Parts and Functions
Camera Lens
Speaker
176 mm
Night View LED
Nameplate Call Button Microphone
Rainy Cover 90 mm
23 mm
Note: 352592 has two call buttons.
2.Terminal Descriptions 1 2 3
ON
Doorstation Code DIP
1 2
ON
1 2
Lock Control Jumper
MIC adjustment SPK adjustment
BUS
-1-
S2+ SPL S1+
Main Connect Port
•• ••
Lock Control Jumper: To select the lock type: see 5.2.1 , 5.2.2
•• •• •• •• ••
Main Connect Port: To connect the bus line and the electronic locks.
Doorstation Code DIP: Total 4 doorstations can be supported,see 6.1
BUS: Connect to the bus line, no polarity. PL: External lock power input, connect to the power positive(power +). S1+, S2+: Lock power(+) output, to connect 2 locks. S-: Lock power(-) output, connect to the power(-) input of locks(only when using the camera to power the locks, if using the external power supply for the locks, the S- will not be connected).
3.Specifications Lock Power supply:
12Vdc, 300mA(Internal Power)
Power Consumtion:
1W in standby, 12W in working
NO, COM dry contact:
Max. 48V dc 1.5A
Unlocking time:
1 to 9 seconds, set by Monitor
Working temperature:
-10ºC ~ 45ºC
4.Mounting 4.1 Mounting Without Rainy Cover 1
2
3 1
2
160-165cm
-2-
4
4.2 Mounting With Rainy Cover
1
2
3
1
2
160-165cm
4.3 Placing Name Label
ON
name label
-3-
1 2
Move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel.
4
4.4 Adjusting Camera Angle
use a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw.
5.System Wiring and Connections
monitor
1 2
ON
5.1 Basic Connection
PRODPS
PROPS4
L1 L2 PL S1+ S2+ S-
+
AC~
-4-
5.2 Electric Lock Connection 5.2.1 Door Lock Controlled with Internal Power Note: 1. Electronic lock of Power-on-to-unlock type should be used. 2. The door lock is limited to 12V, and holding current must be less than 250mA. 3. The door lock control is not timed from Exit Button(EB). 4. The Unlock Mode Parameter of Monitor must be set to 0 (by default). connect one lock
connect two locks
Connect one lock
Connect two locks
Jumper position in 1-2 BUS
PL
S1 +
S2 +
Jumper position in 1-2 BUS
S-
*EB
PL
S1+
S2+
S-
2nd
* EB
2 nd LOCK
LOCK
*EB
1ST 1 ST LOCK
5.2.2 Door Lock Controlled with Dry Contact Note: 1. The external power supply must be used according to the lock. 2. The jumper must be taken off before connecting. 3. Setup the Unlock Mode of Monitor for different lock types. •• Power-on-to-unlock type:Unlock Mode=0 (by default) •• Power-off-to-unlock type:Unlock Mode=1
-5-
connect one lock
connect two locks
Take off the Jumper BUS
PL
S1 +
S2 +
Take off the Jumper
S-
BUS
POWER SUPPLY
PL
S1 +
S2 +
S-
POWER SUPPLY LOCK
LOCK
LOCK
5.2.3 Unlock parameter setting(set on monitor)
Manual Monitor
Memory Playback
Monitor
Album
? About
1.Touch menu page.
Intercom
H/W : S/W: Local addr: Unlock timing: Video standard: UI-CODE: MCM-VER.: Updated:
Multimedia
Close
User Setup
09/30/2010 Thu.16:41
--- a1.3 V17.11.418.00 -----------
2.Touch the screen anywhere and hold for 2s.
item on main
Installation settings: [0010]#:Remove all remote control [0011]#:Add remote control [8000]#:Set as master unit 0 [8001]#:Set as slaver unit 1 [8002]#:Set as slaver unit 2 [8003]#:Set as slaver unit 3 [8004]#:Set as guard unit [8005]#:Set as not guard unit [8006]#:Panel on as slaver unit called [8007]#:Panel off as slaver unit called [8008]#:Date format:MM/DD/YYYY [8009]#:Date format:DD/MM/YYYY [8010]#:Set lock mode to 0 [8011]#:Set lock mode to 1 [8021]~[8029] #Set the lock time of 1~9s Multi language settings: ---
Code Number:[----]
4
2 5
3 6
7
8
9
1
0
Installer setup
Caliber TouchScreen
Cancel
Home
4.A digital keypad and setting instructions will be shown.
3.Touch Installer setup item
Note: 1.must connect 352591/592 correctly before setting. 2.the parameter will be saved in 352591/592 automatically,so you need only set on one monitor. 3.the above diagram is fit for icon menu series monitors only, to text menu series monitors,please refer to the corresponding user manual.
-6-
5.3 Multi Doorstations Connection
monitors
352DBC4
PRODPS
PROS5
A B C D
BUS
85~260VAC
ID=00
ON
ON
ON
1 2
L1 L2 PL S1+ S2+ S-
1# Camera ID=10
ON
ON
1 2
ON
1 2
ON
12
L1 L2 PL S1+ S2+ S-
2# Camera ID=01
ON
1 2
1 2
L1 L2 PL S1+ S2+ S-
1 2
3# Camera ID=11
1 2
4# Camera
L1 L2 PL S1+ S2+ S-
-7-
5.4 Multi Monitors Connection 5.4.1 Basic IN-OUT Wiring Mode
ON
1 2 3 4 56
monitor
Code=15, DIP-6=on
ON
1 2 3 4 5 6
monitor
Code=14, DIP-6=off
ON
1 2 3 4 5 6
monitor
Code=0, DIP-6=off
PROS5
PRODPS
85~260AC
ID=00 ON
1 2
-8-
5.4.2 With PRODBC-4 Wiring Mode ON
ON
1 2 3 4 5 6
monitor
1 2 3 4 5 6
monitor
HI
OUT IN
Code=14, DIP-6=on
Code=15, DIP-6=on
A B C D
352'%C-4
ON
ON
1 2 3 4 5 6
monitor
monitor
Code=12, DIP-6=on
Code=13, DIP-6=on
ON
ON
1 2 3 4 5 6
1 2 3 4 5 6
monitor
1 2 3 4 5 6
HI
monitor OUT IN
Code=2, DIP-6=on
Code=3, DIP-6=on
A B C D
Code=1, DIP-6=on
monitor
1 2 3 4 5 6
monitor
Code=0, DIP-6=on
PRODPS
PROS5
85~260AC
ID=00 ON
1 2
-9-
352DBC-4
ON
ON
1 2 3 4 5 6
6.Setup ON(1) ON
=
OFF(0) ON
=
6.1 DIP Switches Settings of Doorstation Total 2 bits on the DIP switches can be configured.The switches can be modified either before or after installation. Bit state
Descriptions Default setting, ID = 0(00), set to the first Door Station.
ON
1 2
ID = 1(10), set to the second Door Station.
ON
1 2 ON
ID = 2(01), set to the third Door Station.
1 2
ID = 3(11), set to the fourth Door Station.
ON
1 2
6.2 DIP Switches Settings of Monitor There are 6 bit switches in total. The DIP switches are used to configure the User Code for each Monitor. Bit-6 is used to set video impedance,it should be set to ON if the Monitor is in the end of the line(bus), otherwise set to OFF. Bit state ON
1 2 3 4 5 6
Setting The monitor is not at the end of the bus.
-10-
Bit state ON
1 2 3 4 5 6
Setting The monitor is at the end of the bus.
Bit-1 to Bit-5 are used to User Code setting. The value is from 0 to 31, which have 32 different codes . Bit state
User Code Code=0
ON
ON
1 2 3 4 5 6
ON
Code=2
ON
Code=3
ON
Code=4
ON
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=9
ON
Code=10
ON
Code=15
ON
1 2 3 4 5 6
Code=23
ON
Code=24
ON
Code=25
ON
Code=26
1 2 3 4 5 6
Code=16
ON
Code=27
1 2 3 4 5 6
Code=17
ON
Code=28
1 2 3 4 5 6
Code=18
ON
Code=29
1 2 3 4 5 6
Code=19
ON
Code=30
1 2 3 4 5 6
Code=20
1 2 3 4 5 6
1 2 3 4 5 6
ON
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6 ON
Code=14
1 2 3 4 5 6
Code=8
ON
Code=22
1 2 3 4 5 6
1 2 3 4 5 6
Code=7
ON
Code=13
1 2 3 4 5 6
Code=6
ON
ON
User Code
1 2 3 4 5 6
1 2 3 4 5 6
Code=5
ON
Code=12
1 2 3 4 5 6
1 2 3 4 5 6
Bit state
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6 ON
Code=11
1 2 3 4 5 6
1 2 3 4 5 6 ON
User Code
1 2 3 4 5 6
Code=1
ON
Bit state
ON
Code=31
1 2 3 4 5 6
Code=21
1 2 3 4 5 6
Note:Monitors response button A must set the user code from 0 to 15.and button B set the user code from 16 to 31. B A
A
-11-
6.3 Notices
Name
Discription
Usage
Power supply,85~260Vac input,24Vdc/3A Connect with multi doorstations or P52S5-24V output,10 DIN modules multi monitors(up to 2 or above) 3526-24V
Power supply,85~260Vac input,24Vdc/1A Connect with one doorstation and one output,for basic kit only,4 DIN modules monitor(35216 can be connected two)
-12-
7.Cables Requirements The maximum distance of the wiring is limited in the &KDOOHQJHU3UR system. Using different cables may also affect the PD[LPXPGLVWDQFHZKLFKWKHV\VWHPFDQUHDFK
The farest monitor monitor
with two or four monitors
monitor
monitor
PRODBC4
B
C When Monitor quantity < 20 Cable Usage
A
PRODPS
B
C
Twisted cable 2x0.75 mm2
60
60
30
Twisted cable 2x1 mm2
80
80
40
A
When Monitor quantity > 20 Cable Usage
A
PROS5
B
C
Twisted cable 2x1 mm2
70
30
20
Twisted cable 2x1.5 mm2
70
50
30
Note:If the monitor has been specified the distance,refer to the parameter.
-13-
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.