Preview only show first 10 pages with watermark. For full document please download

Pro591_user Manual

   EMBED


Share

Transcript

2 -Wire Intercom System PRO591/592 User Manual PRO591 PRO592 3529,6,216(&85,7<352'8&76 5(9 CONTENTS 1.Parts and Functions............................................................................................. 1 2.Terminal Descriptions........................................................................................... 1 3.Specifications....................................................................................................... 2 4.Mounting............................................................................................................... 2 4.1 Mounting Without Rainy Cover....................................................................... 2 4.2 Mounting With Rainy Cover............................................................................ 3 4.3 Placing Name Label....................................................................................... 3 4.4 Adjusting Camera Angle................................................................................. 4 5.System Wiring and Connections.......................................................................... 4 5.1 Basic Connection........................................................................................... 4 5.2 Electric Lock Connection................................................................................ 5 5.2.1 Door Lock Controlled with Internal Power............................................. 5 5.2.2 Door Lock Controlled with Dry Contact................................................. 5 5.2.3 How to setup the unlock parameter in Monitor....................................... 6 5.3 Multi Doorstations Connection....................................................................... 7 5.4 Multi Monitors Connection.............................................................................. 8 5.4.1 Basic IN-OUT Wiring Mode.................................................................. 8 5.4.2 With PRODBC-4 Wiring Mode.............................................................. 9 6.Setup.................................................................................................................... 10 6.1 DIP Switches Settings of Doorstation............................................................. 10 6.2 DIP Switches Settings of Monitor................................................................... 10 6.3 Notices........................................................................................................... 12 7.Cables Requirements........................................................................................... 13 1.Parts and Functions Camera Lens Speaker 176 mm Night View LED Nameplate Call Button Microphone Rainy Cover 90 mm 23 mm Note: 352592 has two call buttons. 2.Terminal Descriptions 1 2 3 ON Doorstation Code DIP 1 2 ON 1 2 Lock Control Jumper MIC adjustment SPK adjustment BUS -1- S2+ SPL S1+ Main Connect Port •• •• Lock Control Jumper: To select the lock type: see 5.2.1 , 5.2.2 •• •• •• •• •• Main Connect Port: To connect the bus line and the electronic locks. Doorstation Code DIP: Total 4 doorstations can be supported,see 6.1 BUS: Connect to the bus line, no polarity. PL: External lock power input, connect to the power positive(power +). S1+, S2+: Lock power(+) output, to connect 2 locks. S-: Lock power(-) output, connect to the power(-) input of locks(only when using the camera to power the locks, if using the external power supply for the locks, the S- will not be connected). 3.Specifications Lock Power supply: 12Vdc, 300mA(Internal Power) Power Consumtion: 1W in standby, 12W in working NO, COM dry contact: Max. 48V dc 1.5A Unlocking time: 1 to 9 seconds, set by Monitor Working temperature: -10ºC ~ 45ºC 4.Mounting 4.1 Mounting Without Rainy Cover 1 2 3 1 2 160-165cm -2- 4 4.2 Mounting With Rainy Cover 1 2 3 1 2 160-165cm 4.3 Placing Name Label ON name label -3- 1 2 Move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel. 4 4.4 Adjusting Camera Angle use a screwdriver to loosen the screw and then adjust the angle of the camera ,then fix the screw. 5.System Wiring and Connections monitor 1 2 ON 5.1 Basic Connection PRODPS PROPS4 L1 L2 PL S1+ S2+ S- + AC~ -4- 5.2 Electric Lock Connection 5.2.1 Door Lock Controlled with Internal Power Note: 1. Electronic lock of Power-on-to-unlock type should be used. 2. The door lock is limited to 12V, and holding current must be less than 250mA. 3. The door lock control is not timed from Exit Button(EB). 4. The Unlock Mode Parameter of Monitor must be set to 0 (by default). connect one lock connect two locks Connect one lock Connect two locks Jumper position in 1-2 BUS PL S1 + S2 + Jumper position in 1-2 BUS S- *EB PL S1+ S2+ S- 2nd * EB 2 nd LOCK LOCK *EB 1ST 1 ST LOCK 5.2.2 Door Lock Controlled with Dry Contact Note: 1. The external power supply must be used according to the lock. 2. The jumper must be taken off before connecting. 3. Setup the Unlock Mode of Monitor for different lock types. •• Power-on-to-unlock type:Unlock Mode=0 (by default) •• Power-off-to-unlock type:Unlock Mode=1 -5- connect one lock connect two locks Take off the Jumper BUS PL S1 + S2 + Take off the Jumper S- BUS POWER SUPPLY PL S1 + S2 + S- POWER SUPPLY LOCK LOCK LOCK 5.2.3 Unlock parameter setting(set on monitor) Manual Monitor Memory Playback Monitor Album ? About 1.Touch menu page. Intercom H/W : S/W: Local addr: Unlock timing: Video standard: UI-CODE: MCM-VER.: Updated: Multimedia Close User Setup 09/30/2010 Thu.16:41 --- a1.3 V17.11.418.00 ----------- 2.Touch the screen anywhere and hold for 2s. item on main Installation settings: [0010]#:Remove all remote control [0011]#:Add remote control [8000]#:Set as master unit 0 [8001]#:Set as slaver unit 1 [8002]#:Set as slaver unit 2 [8003]#:Set as slaver unit 3 [8004]#:Set as guard unit [8005]#:Set as not guard unit [8006]#:Panel on as slaver unit called [8007]#:Panel off as slaver unit called [8008]#:Date format:MM/DD/YYYY [8009]#:Date format:DD/MM/YYYY [8010]#:Set lock mode to 0 [8011]#:Set lock mode to 1 [8021]~[8029] #Set the lock time of 1~9s Multi language settings: --- Code Number:[----] 4 2 5 3 6 7 8 9 1 0 Installer setup Caliber TouchScreen Cancel Home 4.A digital keypad and setting instructions will be shown. 3.Touch Installer setup item Note: 1.must connect 352591/592 correctly before setting. 2.the parameter will be saved in 352591/592 automatically,so you need only set on one monitor. 3.the above diagram is fit for icon menu series monitors only, to text menu series monitors,please refer to the corresponding user manual. -6- 5.3 Multi Doorstations Connection monitors 352DBC4 PRODPS PROS5 A B C D BUS 85~260VAC ID=00 ON ON ON 1 2 L1 L2 PL S1+ S2+ S- 1# Camera ID=10 ON ON 1 2 ON 1 2 ON 12 L1 L2 PL S1+ S2+ S- 2# Camera ID=01 ON 1 2 1 2 L1 L2 PL S1+ S2+ S- 1 2 3# Camera ID=11 1 2 4# Camera L1 L2 PL S1+ S2+ S- -7- 5.4 Multi Monitors Connection 5.4.1 Basic IN-OUT Wiring Mode ON 1 2 3 4 56 monitor Code=15, DIP-6=on ON 1 2 3 4 5 6 monitor Code=14, DIP-6=off ON 1 2 3 4 5 6 monitor Code=0, DIP-6=off PROS5 PRODPS 85~260AC ID=00 ON 1 2 -8- 5.4.2 With PRODBC-4 Wiring Mode ON ON 1 2 3 4 5 6 monitor 1 2 3 4 5 6 monitor HI OUT IN Code=14, DIP-6=on Code=15, DIP-6=on A B C D 352'%C-4 ON ON 1 2 3 4 5 6 monitor monitor Code=12, DIP-6=on Code=13, DIP-6=on ON ON 1 2 3 4 5 6 1 2 3 4 5 6 monitor 1 2 3 4 5 6 HI monitor OUT IN Code=2, DIP-6=on Code=3, DIP-6=on A B C D Code=1, DIP-6=on monitor 1 2 3 4 5 6 monitor Code=0, DIP-6=on PRODPS PROS5 85~260AC ID=00 ON 1 2 -9- 352DBC-4 ON ON 1 2 3 4 5 6 6.Setup ON(1) ON = OFF(0) ON = 6.1 DIP Switches Settings of Doorstation Total 2 bits on the DIP switches can be configured.The switches can be modified either before or after installation. Bit state Descriptions Default setting, ID = 0(00), set to the first Door Station. ON 1 2 ID = 1(10), set to the second Door Station. ON 1 2 ON ID = 2(01), set to the third Door Station. 1 2 ID = 3(11), set to the fourth Door Station. ON 1 2 6.2 DIP Switches Settings of Monitor There are 6 bit switches in total. The DIP switches are used to configure the User Code for each Monitor. Bit-6 is used to set video impedance,it should be set to ON if the Monitor is in the end of the line(bus), otherwise set to OFF. Bit state ON 1 2 3 4 5 6 Setting The monitor is not at the end of the bus. -10- Bit state ON 1 2 3 4 5 6 Setting The monitor is at the end of the bus. Bit-1 to Bit-5 are used to User Code setting. The value is from 0 to 31, which have 32 different codes . Bit state User Code Code=0 ON ON 1 2 3 4 5 6 ON Code=2 ON Code=3 ON Code=4 ON ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON Code=9 ON Code=10 ON Code=15 ON 1 2 3 4 5 6 Code=23 ON Code=24 ON Code=25 ON Code=26 1 2 3 4 5 6 Code=16 ON Code=27 1 2 3 4 5 6 Code=17 ON Code=28 1 2 3 4 5 6 Code=18 ON Code=29 1 2 3 4 5 6 Code=19 ON Code=30 1 2 3 4 5 6 Code=20 1 2 3 4 5 6 1 2 3 4 5 6 ON 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 ON Code=14 1 2 3 4 5 6 Code=8 ON Code=22 1 2 3 4 5 6 1 2 3 4 5 6 Code=7 ON Code=13 1 2 3 4 5 6 Code=6 ON ON User Code 1 2 3 4 5 6 1 2 3 4 5 6 Code=5 ON Code=12 1 2 3 4 5 6 1 2 3 4 5 6 Bit state 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 ON Code=11 1 2 3 4 5 6 1 2 3 4 5 6 ON User Code 1 2 3 4 5 6 Code=1 ON Bit state ON Code=31 1 2 3 4 5 6 Code=21 1 2 3 4 5 6 Note:Monitors response button A must set the user code from 0 to 15.and button B set the user code from 16 to 31. B A A -11- 6.3 Notices Name Discription Usage Power supply,85~260Vac input,24Vdc/3A Connect with multi doorstations or P52S5-24V output,10 DIN modules multi monitors(up to 2 or above) 3526-24V Power supply,85~260Vac input,24Vdc/1A Connect with one doorstation and one output,for basic kit only,4 DIN modules monitor(35216 can be connected two) -12- 7.Cables Requirements The maximum distance of the wiring is limited in the &KDOOHQJHU3UR system. Using different cables may also affect the PD[LPXPGLVWDQFHZKLFKWKHV\VWHPFDQUHDFK  The farest monitor monitor with two or four monitors monitor monitor PRODBC4 B C When Monitor quantity < 20 Cable Usage A PRODPS B C Twisted cable 2x0.75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 40 A When Monitor quantity > 20 Cable Usage A PROS5 B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1.5 mm2 70 50 30 Note:If the monitor has been specified the distance,refer to the parameter. -13- The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.