Product Data Sheet:
Multi Fiber Cable Assemblies
Applications
•Telecommunications •CATV •Data Center •Harsh Environment •FTTx •SAN, LAN and WAN •Broadband Features and Benefits
•100% factory tested •Interferometer test results available
•Single mode OS2, and
Multimode OM1, OM2, OM3, OM4
assemblies available on request
•All connector styles available
•Bend Insensitive •Pulling eye •Long length provided on easy to use reel
•Individually packaged •Low link loss
Description Whether the multi fiber cable assemblies are used as a building backbone, horizontal distribution, must be operating in an uncontrolled or harsh environment, Wirewerks multi fiber cable assemblies provide the ideal medium for all your fiber optic applications. They are designed, manufactured, and tested in strict compliance with the industry’s specifications and requirements.
Phone: 1-888-993-4237, Fax: 1-888-893-4237 Email:
[email protected], Web Site: www.wirewerks.com
The components’ quality used to build our multi fiber cable assemblies ensures long lasting and high repeatability connections. Wirewerks offers a wide variety of connector options, cable constructions, jacket colors, armoring, as well as different flammability ratings, and have the capability to custom build to meet your most stringent mechanical and performance specifications.
RoHS Compliant PDS-0023-EN-B
page 1
•Quick delivery •Custom multi fiber
Product Data Sheet:
Multi Fiber Cable Assemblies Ordering information Y
A
N
R
XX
Y
AAA
NN
X
YY
A
N
000
FA Y - Fiber Type
Y - Lead OD
X - Polish Side A
A - Polish Side B
N - Accessory
1 = Single Mode OS2 2 = 62.5/125μm Multimode OM1 3 = 50/125μm Multimode OM2 4 = 50/125μm Multimode OM3 5 = 50/125μm Multimode OM4 A = Single Mode OS2 Bend Insensitive 5mm B = 50/125μm Multimode OM2 Bend Insensitive 5mm C = 50/125μm Multimode OM3 Bend Insensitive 5mm D = 50/125μm Multimode OM4 Bend Insensitive 5mm E = Single Mode OS2 Bend Insensitive 10mm
9 = 900μm 2 = 2mm 3 = 3mm Z = N/A
A = APC B = UPC C = PC E = SPC
A = APC B = UPC C = PC D = N/A E = SPC
0 = None 1 = 1 Pulling Eye 2 = 2 Pulling Eyes
A - Cable Type
N - Jacket Type
D = Distribution B = Breakout L = Loose Tube R = Ribbon T = Tactical A = ADSS M = Mini-Distribution
P = OFNP 02 = 2 Fiber R = OFNR 04 = 4 Fiber Z = LSZH 06 = 6 Fiber O = Outdoor 08 = 8 Fiber N = Indoor/Outdoor OFNP 12 = 12 Fiber L = Indoor/Outdoor OFNR 18 = 18 Fiber 24 = 24 Fiber R - Armored Type 36 = 36 Fiber 48 = 48 Fiber N = Non Armored 72 = 72 Fiber B = BX Type 96 = 96 Fiber L = Light Armored C4 = 144 Fiber
AAA - Lead Length XXN = Length in Inches XXM = Length in Meters ZZZ= N/A
NN = Connector Side A*
XX - Fiber Count
SC = SC ST = ST LC = LC FC = FC MT = MTRJ Female MB = MTRJ Male S5 = SMA905 S6 = SMA906 E2 = E2000 ES = ESCON FD = FDDI D4 = D4 MP = MPO Female Type A** MA = MPO Male Type A** BP = MPO Female Type B BA = MPO Male Type B CP = MPO Female Type C CA = MPO Male Type C
YY - Connector Side B SC = SC ST = ST LC = LC FC = FC MT = MTRJ Female MB = MTRJ Male S5 = SMA905 S6 = SMA906 E2 = E2000 ES = ESCON FD = FDDI D4 = D4 MP = MPO Female Type A** MA = MPO Male Type A** BP = MPO Female Type B BA = MPO Male Type B CP = MPO Female Type C CA = MPO Male Type C OE = Pigtail
000 - Assembly Length (m) *If more than one connector type, then place in alphabetical order, i.e. LC before ST, to avoid duplicate of part number creation for the same product. ** By default, cable assemblies with MPO connectors are manufactured with a Type A configuration. If an assembly is connectorized on both sides with an MPO connector, configuration types cannot be mixed. Examples: If a Type A is chosen on one end, the other end MUST also be of Type A configuration. If a Type B is chosen on one end, the other end MUST also be of Type B configuration. If a Type C is chosen on one end, the other end MUST also be of Type C configuration.
Technical Specifications MECHANICAL CHARACTERISTICS Parameter
OPTICAL CHARACTERISTICS Value
Value
Operating Temperature:
-40ºC ~ 60ºC
Storage Temperature:
-40ºC ~ 60ºC
Single mode
Parameter SPC
≤ 0.30dB
≤ 0.30dB
≤ 0.30dB
Insertion Loss for Dual Fiber & Array Connector
≤ 0.50dB
≤ 0.50dB
≤ 0.50dB
≤ 0.50dB
≤ -45dB
≤ -55dB
≤ -65dB
page 2
NA
Certification and Compliance FIBER OPTIC LEADS
MAIN CABLE
FIBER OPTIC CONNECTOR (MPO SHOWN)
CABLE ID
page 2
PC
≤ 0.30dB
TRANSITION ZONE
LEG ID
Multimode APC
Insertion Loss for Single Fiber Connector
Return Loss
FIBER OPTIC CONNECTOR (LC SHOWN)
UPC
EXAMPLE OF MULTIFIBER CABLE ASSEMBLY
Phone: 1-888-993-4237, Fax: 1-888-893-4237 Email:
[email protected], Web Site: www.wirewerks.com
RoHS
Compliant to the directive on Restriction of Hazardous Substances GR-326-CORE Generic Requirements for Single Mode Optical Connectors and Jumper Assemblies. TIA/EIA-455 Series For Fiber Optic Components TIA/EIA-472 Series Premises, Outside Plant, Indoor-Outdoor, and Drop Cables TIA/EIA-568-C.3 Optical Fiber Cabling Components Standards TIA/EIA-598-C Optical Fiber Cable Color Coding EIA/TIA-604 Fiber Optic Connector Intermateability Standard UL 94 Tests for Flammability of Plastic Materials for Parts in Devices and appliances.
RoHS Compliant PDS-0023-EN-B