Product Data Sheet: Damcos™ Brcf 2000

   EMBED


Share

Transcript

Product Data Sheet March 2013 SD 0305-2E07 Damcos BRCF 2000 ™ Hydraulic Single-Acting Balanced Rotary Actuator 90° (Quarter-turn) Fail-Safe TM Data sheet BRCF 2000 - Hydraulic single-acting balanced rotary actuator 90° fail-safe Valve adaption: ™ Damcos BRCF 2000 Adjustment screw, torque: 50 Nm March 2013 Main Dimensions Max. valve shaft intrusion: Actuator shown in closed (fail-safe) position. Approx. 5° Adapter Fastning nut, torque: 60 Nm Intermediate flange Limits for the machining of the adapter. Other shapes on request, please contact DMS. Shape Machined acc. to: mm (max.): All dimensions in mm DIN 6885 58 Performance Performance: Nm break away opening 1207 end closing 605 DIN 79 All dimensions 50 in mm. Spring action Torque 135 bar (no rma l wo Nm rkin urn g ret Sprin g 1008 pres sure ) op en Hydraulic action d se clo break away closing 758 end opening Operation port (B) 0° closed 90° open Note! Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. The BRCF fail safe actuator is “Fail Close” in the standard version. Optionally a “Fail Open “ version can be ordered. In case of Fail Open the above torque curve and operation chart is opposite. Standard version; Fail close; Opens by means of hydraulic pressure applied to port B and closes with spring force, when pressure on B port is released. Optional version; Fail Open; Closes by means of hydraulic pressure applied to port A and opens with spring force, when pressure on port A is released. 2 2/2 SD 0305-2E03 Nov. 2001 Damcos™ BRCF 2000 March 2013 Valve Adaption BRCF 2000 - Hydraulic single-acting balanced rotary actuator 90° fail-safe Data sheet Valve adaption: Max. valve shaft intrusion: Adjustment screw, torque: 50 Nm Approx. 5° Adapter Fastning nut, torque: 60 Nm Intermediate flange Limits for the machining of the adapter. Other shapes on request, please contact DMS. Shape Machined acc. to: mm (max.): All dimensions in mm DIN 6885 58 Performance: Specification Technical Working pressure Burst test Torque Nm break away opening 1207 Oil displacement Temperature range Rotation end closing 605 Hydraulic media and viscosities urn g ret Sprin Spring action 135 bar Nm op en 675 bar 13 bar Total dry weight incl. mounting set (10.15kg) (no rma 66.7 kg l wo rkin l 0.400 g 1008 pres Hydraulic action d se clo break away closing s ure) -20°C to +80°C 90°±1° DIN 79 50 758 end opening We recommend acid-free hydraulic oil. Viscosity range: 15-200 cSt. For recommended brands and for other media than oil please refer toOperation sepaport (B) rate data sheet. 0° closed 90° open Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 3 2/2 SD 0305-2E03 Nov. 2001 Damcos™ BRCF 2000 Product Data Sheet SD 0305-2E07 March 2013 ©2013 Emerson Process Management. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Co. Damcos® and the Damcos logotype are registered trademarks of Damcos A/S, Rosemount® TankRadar and the Rosemount logotype are registered trademarks of Rosemount Tank Radar AB. Emerson Process Management Damcos A/S Aaderupvej 41 DK-4700 Naestved T +45 5578 7200 F +45 5578 7272 www.EmersonProcesss.com/mtm TM The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. Standard Terms and Conditions of Sale can be issued by contacting Damcos A/S or Rosemount Tank Radar AB. We reserve the right to modify or improve the designs and specifications of our products at any time without notice. Damcos A/S and Rosemount Tank Radar AB accepts no responsibility for any errors that may appear in this publication.