Transcript
Product Guide
Click Here
SYSTIMAX® Structured Connectivity Solutions
Product Guide SYSTIMAX® Structured Connectivity Solutions
Page No.
1 COPPER
FIBRE
FIBRE
(Click on any of the products below)
7
INDOOR
GigaSPEED® Cables Power Sum Cables Category 3 Cables
9 21 28
OUTDOOR
Power Sum Cables ASP Filled Core Cables
33 35
INDOOR
LazrSPEED™
36
OptiSPEED™
38
OUTDOOR
LazrSPEED OptiSPEED
43 44
INDOOR/OUTDOOR
OptiSPEED
48
2 COPPER
CABLES
CORDS
GigaSPEED
53 D8CM D8CH 117CM 119P8CM, 120CM VisiPatch™
55 60 61 62 64 67 68 69
POWER SUM
110P2CAT5F 110P2CAT5L D8CN
71 73 74
MISCELLANEOUS
25-Pair Cords D8EX Cross-over Cords
75 78
LazrSPEED
LC ST SC Hybrid
79 80 81 82
OptiSPEED
LC
84
ST
87
SC
89
Hybrid
92
Pigtails LC, SC, ST
97
Patch Cords Colour Codes
98
Pigtails Colour Codes
98
CONTENTS
119P8UP 110GS D8MC6
MISCELLANEOUS
Next Page
1
Back
Page No.
3 COPPER
PANELS
101
110 FAMILY
VisiPatch System
103
SHELVES
VisiPatch
105
110 FAMILY
RJ45 PANELS
VisiPatch
107
110 Connector System
108
Wiring Blocks
109
Patch Panels
115
Jack Panels
117
Accessories
120
iPatch™ System
125
1100PSE Panels
126
1100GS Panels
127
2500CAT5PS & 2512CAT5PS Panels
128
Accessories
129
FLEXIMAX
Fleximax HD Panel
131
PATCH PANELS
Introduction
132
PATCHMAX GigaSPEED ®
133
PATCHMAX PowerSum/OptiSPEED & LazrSPEED 134 MULTIMEDIA
MULTIMEDIA
FIBRE
LIUs
CONTENTS
SHELVES
4 COPPER
2
MultiMAX
136
LazrSPEED
137
Interconnection Unit
138
Accessories
140
600ALS Combination Shelf
143
600BLS Combination Shelf
144
LSTLS High Density
145
1100 Fibre Distribution Panel
146
600A1 Shelf
147
600A1 Shelf Accessories
148
600 Series Shelf Accessories
149
600B2 Shelf
150
600B2 Shelf Accessories
151
LGX Shelves
152
LGX Accessories
156
OUTLETS
157
HDMs
GigaSPEED MGS300 Series Category 5 - MPS100E Series Icons & M-Series Cap Category 3 - M1 Series
159 161 163 165
FACEPLATES
US Standard UK/Ireland Standard
166 168
Next Page
Back
Page No.
4
FIBRE
MULTIMEDIA
OUTLETS (continued)
157
French Standard Italian Standard Scandinavian Standard Benelux/German Standard Universal Standard
169 170 171 173 174
FURNITURE
Modular Faceplate
179
FIBRE
Surface Mounted
180
MULTIMEDIA
Surface Mounted
181
5
CONNECTORS
183
COPPER
RJ45 FAMILY
700A8
185
FIBRE
LC FAMILY
LC Connectors LazrSPEED LC Couplings
186 189 190
SC FAMILY
SC Connectors SC Connector Clip SC Couplings
191 192 193
ST FAMILY
ST Connectors ST Couplings
194 196
6 COPPER
197 RJ45 to RJ45 Adapter RJ45 to 110 RJ45 to 50-Pin RJ45 to DB-25 RJ45 Splitters RJ45 Bridge
199 200 201 203 205 207
TRANSMISSION
Token Ring 4/16 Mb/s IBM AS/400 IBM 3170/3270 EIA-232-D Video ISDN
208 209 211 212 214 225
PROTECTORS
CONTENTS
CONNECTIVITY
7 COPPER
ADAPTERS
Next Page
227
PANELS
Small Pair Count - 110ANA1 489 A&B Models
229 230
UNITS
4B1-EW & 4C3S-75 Protector Units Category 5 OSP Protector
231 233
3
Back
Page No
8
TOOLS
235
COPPER
COPPER
Termination Tools
237
FIBRE
FIBRE
Connector Termination Tool Kit Splice Tool Kit
238 245
CONSUMABLES
Kits Supplies
246 256
9
MISCELLANEOUS
COPPER
CLAMPS
B-Bond Clamp
261
FIBRE
CLAMPS
Cable Clamps
262
CONSUMABLES
Buffer Tubing Kit Splitter Kit
263 264
SPLICING
Cleave Sleeve & Leave
266
TESTING
4-Pair Tester
267
COMCODE/PRODUCT
CONTENTS
271
COMCODE
Index
273
PRODUCT
Index
282
APPENDIX
4
259
294 Glossary Warranty Abbreviations Registered Trademarks
295 320 322 324
Avaya Connectivity Solutions EMEA Representative Offices
325
Next Page.
Introduction
Next Page
Today’s real world demands real-time response. In this e-Business era, organisation’s systems are increasingly becoming mission critical. Powerful business models demand high-quality, fast communications solutions. Future-proofing your network infrastructure for the communication & technological demands of the new world economy is no longer an option. It’s a necessity. Avaya is about speed, innovation and integration. We break down the barriers between technologies to make it easier for people to share information and create value for their business. Listening to our customers and working closely with our partners to offer the right solutions at the right time for every customer’s business goals. We specialise in developing advanced solutions that help organisations manage voice, data and video communications over a single multi-service infrastructure. While the Avaya name is new, its foundation has deep roots. Avaya is the former Enterprise Networks Group of Lucent Technologies, which has been in business for over 130 years. SYSTIMAX® Structured Connectivity Solutions are a perfect example of Avaya’s advanced solutions and the innovative ingenuity that Avaya brings to the communications industry. SEAMLESS COMMUNICATION FROM A TRUE END-TO-END SOLUTION The SYSTIMAX Structured Connectivity Solutions provide the benefits of a true end-to-end solution – the highest levels of performance and reliability from products designed by a single source to work in harmony with one another. Developed in anticipation of the high bandwidth requirements of tomorrow’s business environment, SYSTIMAX product innovations in cable design constantly push the boundaries of bandwidth and throughput. SYSTIMAX offers a combination of copper and fibre media: The SYSTIMAX GigaSPEED® Solution – with performance guaranteed to meet or exceed Category 6/Class E Channel Specifications, bandwidth is high and bit error rates are low, providing the ultimate performance over copper. SYSTIMAX channels comprised exclusively of GigaSPEED passive products, end-to-end, are capable of delivering 1.2 Gb/s to the workstation. The GigaSPEED Solution comfortably handles gigabit applications such as 1000BASE-T, whilst enabling users to get the best from their 100BASE-T applications.
●
The Power Sum Solution - developed to provide a more robust cabling system than Category 5 due to the evolution of sophisticated 100 Mb/s applications. Power Sum channel performance specifications exceed not only the current ratified and proposed standards in TIA and ISO for Enhanced Category 5 cabling systems, but are also capable of providing stable and continual performance up to 155.5 MHz.
●
The LazrSPEED™ Solution - the world’s most advanced multimode fibre solution. With performance guaranteed to meet or exceed the proposed OM3 next generation multimode fibre specification, LazrSPEED delivers unsurpassed bandwidth and laser optimised performance for building and campus backbones. Enabling lowest cost / complexity implementation of 10 Gb/s Ethernet, while still supporting 10 Mb/s through 1 Gb/s and other legacy applications, all over at least 300 metres.
CONTENTS
●
The OptiSPEED™ Solution - developed to provide a fibre optic solution that is the backbone for both today’s performance requirements and the networks of the future, it offers multimode and singlemode fibre cable. 62.5 micron multimode fibre provides high-speed links to support signal transmission up to the TIA standard of 300 meters within a building, and up to 2000 meters or 2 kilometres within a campus for many of today’s legacy LAN’s. The OptiSPEED channel, which includes the low loss LC Connector, supports the 1000BASE-SX, Gigabit Ethernet LAN, up to 300 meters with 6 LC connections. Plenum versions of all SYSTIMAX cables are available for areas of particular fire sensitivity. These compliment standard and Low Smoke Zero Halogen (LSZH) SYSTIMAX cables. Our integrated approach offers many benefits including reliability, flexibility, performance and value. Moreover, we ensure our customers benefit from:
5
Introduction (contd)
Click Here Main Menu
●
Competitive advantage through end-to-end tested components that eliminate the risk of incompatibility. With a solution sourced from multiple vendors, incompatibility problems may only become apparent when changes are made to the system or high-speed networks are required.
●
Investment protection with incremental evolution. Open architecture supports equipment and applications of many electronics vendors — including data terminals, analogue and digital telephones, personal computers, video teleconferencing and host computers, as well as common system equipment.
●
Decreased maintenance costs. Faultfinding and resolution can be particularly expensive and time consuming in multi-vendor networks. SYSTIMAX components can be obtained from a single source, which reduces cost and improves response time.
●
Increased reliability for maximum up-time. Minimised network outage risk and/or decreased outage duration. An end-to-end SYSTIMAX solution can cut down time by between 50% to 80%.
HIGH PERFORMANCE CONNECTIVITY BASED ON WORLD-CLASS R&D As worldwide market leader SYSTIMAX is known for setting industry trends, and driving the development of new cabling standards. This is possible because of Avaya Labs. Building on their Bell Labs heritage, the 3,000+ R&D professionals at Avaya Labs create, obtain and rapidly deliver competitive technology for the world’s best communications solutions that allow businesses to excel. Most members of Avaya Labs R&D community work in Avaya’s business units, applying innovation and technical excellence to deliver real solutions to real world problems, producing unparalleled value for customers. Research at Avaya is closely coupled to the needs of the business, and is focused on technologies that are vital to Avaya’s business strategy. On-going development of the SYSTIMAX Structured Connectivity Solutions at Avaya Labs assures Avaya’s position at the leading edge of structured cabling design, as well as its market leading position. LEADING THE WORLD OF STANDARDS The SYSTIMAX Solutions meet or exceed all major cabling standards, and those currently in development. In fact, Avaya Labs has a strong presence in all major standards organisations world-wide, including: ●
INTRODUCTION
● ● ● ● ●
TIA (Telecommunications Industry Association) EIA (Electronic Industry Association) IEEE (Institute of Electrical and Electronic Engineers) ATM Forum ISO (International Standards Organisation) ANSI (American National Standards Institute)
PEACE OF MIND WITH THE BEST WARRANTY IN THE BUSINESS The quality of a connectivity solutions’ warranty is the best assurance that system faults will not result in unexpected costs. The SYSTIMAX warranty covers not only your system components, but also the performance of specific applications for a full 20 years. No one can match the advantage of the SYSTIMAX SCS Extended Product Warranty and Application Assurance Programme. Not only is the product warranty on the passive components extended to 20 years for all certified sites, but the applications assurance covers future applications you may want to support – applications that haven’t even been developed yet. By warranting any future applications that meet recognised standards using ISO/IEC IS 11801 or TIA/EIA 568-A, Avaya allows you to virtually “future proof” your connectivity infrastructure. But it doesn’t stop there. The applications assurance is further enhanced by including EMC compliance assurance for all registered SYSTIMAX installations. SYSTIMAX Structured Connectivity Solutions – the essential foundation for networks in the eBusiness era
6
Cables Chapter
1
7
Ca b l e s Contents
Click Here Main Menu
Copper INDOOR GigaSPEED® Cables
9
Power Sum Cables
21
Category 3 Cables
28
OUTDOOR Power Sum Cables
33
ASP Filled Core Cable
35
Fibre INDOOR LazrSPEED™
36
OptiSPEED™
38
OUTDOOR LazrSPEED
43
OptiSPEED
44
INDOOR/OUTDOOR OptiSPEED
8
48
Copper
GigaSPEED® Cables
Indoor
1081 4-Pair Cable
Cable Contents Page
The 1081 4-Pair GigaSPEED Cable features an innovative fluted design to guide the pairs inside the jacket and provide unrivaled transmission performance. The precision manufacturing process and design of the 1081 4-Pair GigaSPEED Cable maximises performance and significantly reduces signal emissions and susceptability to external noise. The 1081 cable provides significant margin (10 dB) above the minimum Category 6 Near End Crosstalk NEXT requirements of TIA/EIA (Draft 7) and ISO/IEC 11801 2nd
Figure 1
Edition (1st Committee Draft)
1081 4-Pair Cable
1081 Cables are UL listed CM.
Physical Specifications Gauge: 24 AWG Outside Diameter: 6.4 mm Weight: 12.93 kg
Attenuation
NEXT
PS NEXT
ELFEXT
PSELFEXT
Return Loss
0.772
1.6
86.0
84.0
70.0
67.0
–
1
1.8
84.3
82.3
67.8
64.8
20
4
3.6
75.3
73.3
55.7
52.7
23
8
5.1
71.8
68.8
49.7
46.7
24.5
10
5.8
69.3
67.3
47.8
44.8
25
16
7.3
66.3
64.3
43.7
40.7
25
20
8.2
64.8
62.8
41.7
38.7
25
25
9.2
63.3
61.3
39.8
36.8
24
31.25
10.4
61.9
59.9
37.9
34.9
24
62.5
15.0
57.4
55.4
31.8
28.8
22
100
19.3
54.3
52.3
27.8
24.8
20
200
28.3
49.8
47.8
21.7
18.7
18
250
32.1
48.3
46.3
19.8
16.8
17
300
35.6
47.2
45.2
18.2
15.2
17
350
38.9
46.2
44.2
16.9
13.9
16
400
42.0
45.3
43.3
15.7
12.7
16
450
45.0
44.5
42.5
14.7
11.7
16
500
47.9
43.8
41.8
13.8
10.8
15
550
50.6
43.2
41.2
12.9
9.9
15
copper CABLES
Frequency (MHz)
9
Copper
GigaSPEED Cables
Indoor
copper CABLES
1081 4-Pair Cable (contd)
10
Product
Comcode
Length
Colour
1081004ASL
108744921
915m (3000ft)
Slate
1081004AWH
108744939
915m (3000ft)
White
1081004ABL
108744947
915m (3000ft)
Blue
1081004ASL
108680802
305m (1000ft)
Slate
1081004ALB
108680810
305m (1000ft)
Light Blue
1081004ABL
108680869
305m (1000ft)
Blue
1081004AIV
108680877
305m (1000ft)
Ivory
1081004AYL
108680885
305m (1000ft)
Yellow
1081004ARD
108680893
305m (1000ft)
Red
1081004AWH
108681115
305m (1000ft)
White
1081004AGN
108681131
305m (1000ft)
Green
1081004ABK
108744954
305m (1000ft)
Black
1081004ALL
108681149
305m (1000ft)
Lilac
1081004AOR
108681156
305m (1000ft)
Orange
Cable Contents Page
Copper
GigaSPEED Cables
Indoor
2081 Plenum Cable 4-Pair
Cable Contents Page
The 2081 4-Pair GigaSPEED Cable features an innovative fluted design to guide the pairs inside the jacket and provide unrivaled transmission performance. The precision manufacturing process and design of the 2081 4-Pair GigaSPEED Cable maximises performance and significantly reduces signal emissions and susceptability to external noise. The 2081 Cable provides significant margin (10 dB) above the minimum Category 6 Near End Crosstalk (NEXT) and Power Sum NEXT requirements of TIA/EIA (Draft 7) and ISO/IEC 11801 2nd Edition (1st Committee Draft). 2081 Cables are composed of 0.511mm (24AWG) solid copper conductors insulated with FluorinatedEthylene-Propylene (FEP) and jacketed with Low Smoke PVC. 2081 are UL Listed CMP.
Physical Specifications Gauge: 24 AWG Outside Diameter: 6.1 mm Weight: 14.38 Kg
Frequency (MHz)
Attenuation
NEXT
PS NEXT
ELFEXT
PSELFEXT
Return Loss
1.6
86.0
84.0
70.0
67.0
–
1
1.8
84.3
82.3
67.8
64.8
20
4
3.6
75.3
73.3
55.7
52.7
23
8
5.1
71.8
68.8
49.7
46.7
24.5
10
5.8
69.3
67.3
47.8
44.8
25
16
7.3
66.3
64.3
43.7
40.7
25
20
8.2
64.8
62.8
41.7
38.7
25
25
9.2
63.3
61.3
39.8
36.8
24
31.25
10.4
61.9
59.9
37.9
34.9
24
62.5
15.0
57.4
55.4
31.8
28.8
22
100
19.3
54.3
52.3
27.8
24.8
20
200
28.3
49.8
47.8
21.7
18.7
18
250
32.1
48.3
46.3
19.8
16.8
17
300
35.6
47.2
45.2
18.2
15.2
17
350
38.9
46.2
44.2
16.9
13.9
16
400
42.0
45.3
43.3
15.7
12.7
16
450
45.0
44.5
42.5
14.7
11.7
16
500
47.9
43.8
41.8
13.8
10.8
15
550
50.6
43.2
41.2
12.9
9.9
15
copper CABLES
0.772
11
Copper
GigaSPEED Cables
Indoor
copper CABLES
2081 Plenum Cable 4-Pair (contd)
12
Product
Comcode
Length
Packaging
2081004AWH
108681172
305m (1000ft)
White
2081004ABL
108681180
305m (1000ft)
Blue
2081004ASL
108681214
305m (1000ft)
Slate
2081004ABK
108681230
305m (1000ft)
Black
Cable Contents Page
Copper
GigaSPEED Cables
Indoor
3081 Low Smoke Zero Halogen 4-Pair
Cable Contents Page
The 3081 4-Pair GigaSPEED Cable features an innovative fluted design to guide the pairs inside the jacket and provide unrivalled transmission performance. The precision manufacturing process and design of the 3081 4-Pair GigaSPEED Cable maximise performance and significantly reduces signal emissions and susceptability to external noise. 3081 Cables are composed of 0.511mm (24AWG) solid copper conductors insulated with non-halogen high
Figure No 2
density polyethylene and jacketed with a low smoke zero
3081 Low Smoke Zero
halogen compound.
Halogen 4-Pair
The 3081 LSZH Cable is IEC tested for low smoke and non-halogen emission and passes the following tests:- IEC 754 part 2, Non-Halogen based on pH and Conductivity Measurements - IEC 1034 part 2, Smoke emission - IEC 332 part 3, Flammability and Fire retardant - NES 713: Toxicity index The 3081 cable provides significant margin (10 dB) above the minimum Category 6 Near End Crosstalk (NEXT) and Power Sum NEXT requirements of TIA/EIA (Draft 7) and ISO/IEC 11801 2nd Edition (1st Committee Draft).
Physical Specifications copper CABLES
Gauge: 24 AWG Outside Diameter: 6.4 mm
13
Copper
GigaSPEED Cables
Indoor
copper CABLES
3081 Low Smoke Zero Halogen 4-Pair (contd)
14
Frequency (MHz)
Attenuation
NEXT
PS NEXT
ELFEXT
PSELFEXT
Return Loss
0.772
1.6
86.0
84.0
70.0
67.0
–
1
1.8
84.3
82.3
67.8
64.8
20
4
3.6
75.3
73.3
55.7
52.7
23
8
5.1
71.8
68.8
49.7
46.7
24.5
10
5.8
69.3
67.3
47.8
44.8
25
16
7.3
66.3
64.3
43.7
40.7
25
20
8.2
64.8
62.8
41.7
38.7
25
25
9.2
63.3
61.3
39.8
36.8
24
31.25
10.4
61.9
59.9
37.9
34.9
24
62.5
15.0
57.4
55.4
31.8
28.8
22
100
19.3
54.3
52.3
27.8
24.8
20
200
28.3
49.8
47.8
21.7
18.7
18
250
32.1
48.3
46.3
19.8
16.8
17
300
35.6
47.2
45.2
18.2
15.2
17
350
38.9
46.2
44.2
16.9
13.9
16
400
42.0
45.3
43.3
15.7
12.7
16
450
45.0
44.5
42.5
14.7
11.7
16
500
47.9
43.8
41.8
13.8
10.8
15
550
50.6
43.2
41.2
12.9
9.9
15
Product
Comcode
Length
Colour
3081004AWH
108687682
915m (3000ft)
White
3081004AWH
108687658
305m (1000ft)
White
3081004ABL
108687674
305m (1000ft)
Blue
3081004ABL
108687690
915m (3000ft)
Blue
Cable Contents Page
Copper
GigaSPEED Cables
Indoor
1071 4-Pair Cable
Cable Contents Page
1071 4-Pair GigaSPEED Cables are designed to support emerging high-bandwidth applications, including the IEEE 802.3ab 1000BASE-T (Gigabit Ethernet), TIA/EIA 1000BASETX, 1.2 Gb/s ATM and any future applications designed for Category 6/Class E cabling, as well as analogue broadband video up to 550 MHz. The 1071 GigaSPEED Cables are designed to transmit data at rates six times faster than Listed
Category 5 cables with unequalled reliability. The precision manufacturing process and design include a thin and easy to remove bisector tape, maximises performance and significantly reduces signal emissions
Figure 3 1071 Cable 4-Pairs
and susceptibility to external noise. 1071 Cables are UL listed CM.
Figure 4 WE TOTE® Box Packaging
Physical Specifications Gauge: 24 AWG
Weight: 10.9kg/305m
Outside Diameter: 6.0mm
Max. Pulling Tension: 11kg
Operating Temperature Range: -20 to 60ºC
Breaking Pulling Tension: 41kg
copper CABLES
Electrical Specifications Nom. Velocity of prop. (NVP): 0.69
Max. DC Resistance: 9.4ohms/100m
Max. DC Resistance Unbal.: <3%
Mut. Capacitance @ 1 kHz: 5.6nF/100m
15
Copper
Header roman GigaSPEED Cables
Indoor
copper CABLES
1071 4-Pair Cable (contd)
16
Frequency (MHz)
Attenuation
NEXT
PS NEXT
ELFEXT
PSELFEXT
Return Loss
0.772
1.6
76.0
74.0
70.0
67.0
–
1
1.8
74.3
72.3
67.8
64.8
20
4
3.6
65.3
63.3
55.7
52.7
23
8
5.1
60.8
58.8
49.7
46.7
24.5
10
5.8
59.3
57.3
47.8
44.8
25
16
7.3
56.3
54.3
43.7
40.7
25
20
8.2
54.8
52.8
41.7
38.7
25
25
9.2
53.3
51.3
39.8
36.8
24
31.25
10.4
51.9
49.9
37.9
34.9
24
62.5
15.0
47.4
45.4
31.8
28.8
22
100
19.3
44.3
42.3
27.8
24.8
20
200
29.3
39.8
37.8
21.7
18.7
18
250
32.1
38.3
36.3
19.8
16.8
17
300
35.6
37.2
35.2
18.2
15.2
17
350
38.9
36.2
34.2
16.9
13.9
16
400
42.0
35.3
33.3
15.7
12.7
16
450
45.0
34.5
32.5
14.7
11.7
16
500
47.9
33.8
31.8
13.8
10.8
15
550
50.6
33.2
31.2
12.9
9.9
15
Product
Comcode
Length
Packaging
Colour
1071004CSL
107987166
305m (1000ft)
WE TOTE
Grey
1071004CSL
108232182
1340m (4400ft)
Reel
Slate
1071004CSL
107987141
305m (1000ft)
Reel
Grey
1071004CBL
107987174
305m (1000ft)
WE TOTE
Blue
1071004CIV
107987208
305m (1000ft)
WE TOTE
Ivory
1071004CSL
107987232
1200m (4000ft)
Reel
Grey
1071004CYL
107987257
305m (1000ft)
WE TOTE
Yellow
1071004CRD
10798729
305m (1000ft)
WE TOTE
Red
1071004CWH
107987315
305m (1000ft)
WE TOTE
White
1071004CGN
107987349
305m (1000ft)
WE TOTE
Green
1071004CRE
107987356
305m (1000ft)
Reel
Berry Red
1071004CLL
107987372
305m (1000ft)
WE TOTE
Lilac
1071004COR
107987380
305m (1000ft)
Reel
Orange
Cable Contents Page
Copper
GigaSPEED Cables
Indoor
2071 4-Pair Cable
Cable Contents Page
The 2071 4-Pair GigaSPEED Cables are designed to support emerging high-bandwidth applications, including the IEEE 802.3ab 1000BASE-T (Gigabit Ethernet), TIA/EIA 1000BASE-TX, 1.2 Gb/s ATM and any future applications designed for Category 6/Class E cabling, as well as analogue broadband video up to 550 MHz. The 2071 GigaSPEED Cables are designed to transmit data at rates six times faster than Category 5 cables with unequalled reliability. The precision manufacturing process and design of the 2071 4-Pair GigaSPEED Cable maximises performance and significantly reduces signal emissions and susceptability to external noise. The 2071 4-Pair Cable is composed of 24-AWG (0.5mm) bare solid-copper conductors insulated with Fluorinated-Ethylene-Propylene (FEP). The core of twisted pairs is jacketed with a low-smoke PVC. It conforms to the low-flame, low-smoke requirements of the NEC. The 2071 4-Pair Cables meet or exceed the Category 6 Near End Crosstalk (NEXT) and Power Sum NEXT requirements of TIA/EIA (Draft 7) and ISO/IEC 11801 2nd Edition (1st Committee Draft). Listed
2071A Cables are UL listed CMP.
Frequency (MHz)
Attenuation
NEXT
PS NEXT
ELFEXT
PSELFEXT
Return Loss
0.772
1.6
76.0
74.0
70.0
67.0
–
1
1.8
74.3
72.3
67.8
64.8
20
4
3.6
65.3
63.3
55.7
52.7
23
8
5.1
60.8
58.8
49.7
46.7
24.5
10
5.8
59.3
57.3
47.8
44.8
25
16
7.3
56.3
54.3
43.7
40.7
25
20
8.2
54.8
52.8
41.7
38.7
25
9.2
53.3
51.3
39.8
36.8
24
31.25
10.4
51.9
49.9
37.9
34.9
24
62.5
15.0
47.4
45.4
31.8
28.8
22
100
19.3
44.3
42.3
27.8
24.8
20
200
29.3
39.8
37.8
21.7
18.7
18
250
32.1
38.3
36.3
19.8
16.8
17
300
35.6
37.2
35.2
18.2
15.2
17
350
38.9
36.2
34.2
16.9
13.9
16
400
42.0
35.3
33.3
15.7
12.7
16
450
45.0
34.5
32.5
14.7
11.7
16
500
47.9
33.8
31.8
13.8
10.8
15
550
50.6
33.2
31.2
12.9
9.9
15
copper CABLES
25
17
Copper
GigaSPEED Cables
Indoor
2071 4-Pair Cable (contd)
Physical Specifications Gauge: 24 AWG
Weight: 10kg/305m
Outside Diameter: 5.1mm
Max. Pulling Tension: 11kg
Operating Temperature Range: -20 to 60ºC
Breaking Pulling Tension: 41kg
copper CABLES
Electrical Specifications
18
Nom. Velocity of prop. (NVP): 0.72
Max. DC Resistance: 9.4ohms/100m
Max. DC Resistance Unbal.: <3%
Mut. Capacitance @ 1 kHz: 4.9nF/100m
Product
Comcode
Length
Packaging
Colour
2071004AWH
107987760
305m (1000ft)
We Tote
White
2071004AWH
107987745
305m (1000ft)
Reel
White
Cable Contents Page
Copper
GigaSPEED Cables
Indoor
3071 Low Smoke Zero Halogen 4-Pair Cable
Cable Contents Page
The 3071 4-Pair GigaSPEED Cable is designed to support emerging high-bandwidth applications, including the IEEE 802.3ab 1000BASE-T (Gigabit Ethernet), TIA/EIA 1000BASE-TX, 1.2 Gb/s ATM and any future applications designed for Category 6/Class E cabling, as well as analogue broadband video up to 550 MHz. The 3071 GigaSPEED cable is designed to transmit data at rates six times faster than Category 5 cables with unequalled reliability. The precision manufacturing process and design of the 3071 4-Pair GigaSPEED Cable maximises performance and significantly reduces signal emissions and susceptability to external noise. 3071 Cable is composed of 0.511 mm (24-AWG) solid-copper conductors insulated with non-halogen high density polyethylene and jacketed with a low smoke zero halogen compound. The 3071 LSZH Cable is IEC tested for low smoke and non-halogen emission and passes the following tests: - IEC 754 part 2, Non-halogen based on pH and Conductivity Measurements - IEC 1034 part 2, Smoke emission - IEC 332 part 3, Flammability and Fire retardant - NES 713: Toxicity index The 3071 4-Pair Cable meet or exceeds the Category 6 Near End Crosstalk (NEXT) and Power Sum Listed
NEXT rerquirements of TIA/EIA (Draft 7) and ISO/IEC 11801 2nd Edition (1st Committee Draft).
Attenuation
NEXT
PS NEXT
ELFEXT
PSELFEXT
Return Loss
0.772
1.6
76.0
74.0
70.0
67.0
–
1
1.8
74.3
72.3
67.8
64.8
20
4
3.6
65.3
63.3
55.7
52.7
23
8
5.1
60.8
58.8
49.7
46.7
24.5
10
5.8
59.3
57.3
47.8
44.8
25
16
7.3
56.3
54.3
43.7
40.7
25
20
8.2
54.8
52.8
41.7
38.7
25
25
9.2
53.3
51.3
39.8
36.8
24
31.25
10.4
51.9
49.9
37.9
34.9
24
62.5
15.0
47.4
45.4
31.8
28.8
22
100
19.3
44.3
42.3
27.8
24.8
20
200
29.3
39.8
37.8
21.7
18.7
18
250
32.1
38.3
36.3
19.8
16.8
17
300
35.6
37.2
35.2
18.2
15.2
17
350
38.9
36.2
34.2
16.9
13.9
16
400
42.0
35.3
33.3
15.7
12.7
16
450
45.0
34.5
32.5
14.7
11.7
16
500
47.9
33.8
31.8
13.8
10.8
15
550
50.6
33.2
31.2
12.9
9.9
15
copper CABLES
Frequency (MHz)
19
Copper
GigaSPEED Cables
Indoor
3071 Low Smoke Zero Halogen 4-Pair Cable (contd) Physical Specifications Gauge: 24 AWG
Weight: 11.4kg/305m
Outside Diameter: 5.8mm
Max. Pulling Tension: 11kg
Operating Temperature Range: -20 to 60ºC
Breaking Pulling Tension: 41kg
copper CABLES
Electrical Specifications
20
Nom. Velocity of prop. (NVP): 0.69
Max. DC Resistance: 9.4ohms/100m
Max. DC Resistance Unbal.: <3%
Mut. Capacitance @ 1 kHz: 5.6nF/100m
Product
Comcode
Length
Packaging
Colour
3071004AWH
107987943
305m (1000ft)
Reel
White
3071004AWH
107987950
305m (1000ft)
We Tote box
White
3071004AWH
107987976
1340m (4400ft)
Reel
White
3071004ABL
107987984
305m (1000ft)
Reel
Blue
3071004ABL
107987992
1340m (4400ft)
Reel
Blue
Cable Contents Page
Copper
Power Sum
Indoor
1061C 4-Pair Cable
Cable Contents Page
1061C 4-Pair Cable is composed of 0.511 mm (24-AWG) bare solid-copper conductors insulated with high density polyolefin. The insulated conductors are tightly twisted into pairs and jacketed with Avaya’s specially formulated PVC Material. The 1061C 4-Pair is a high-speed, 100 ohm high performance cable with excellent pair-to-pair NEXT levels. 1061C provides excellent high speed transmission, is specified out to 155 MHz and supports applications such as 155 Mb/s ATM, 622 Mb/s ATM and the proposed IEEE 802.3 1000Base-T
Figure 5
(Gigabit Ethernet) standard, using parallel transmission
1061 4-Pair Cable
scheme technology in conjunction with other SYSTIMAX® SCS components. The 1061C 4-Pair Cables are UL Verified Category 5e standard, 1061C 25-Pair cables meet or exceed the Category 5 requirements in ISO/IEC 11801, CENELEC EN50173 and Listed
EIA/TIA 568A. Further, they are also UL listed CM.
Figure 6 WE TOTE Box Packaging
Physical Specifications Gauge: 24 AWG
Weight: 31kg/km
Outside Diameter: 5.4mm
Insulation Thickness: 0.2mm
Jacket Thickness: 0.61mm
Max. Pulling Tension: 11.4 kg
Breaking Pulling Tension: 41kg
Operating Temperature Range: -20 to 60ºC
r i c a l S p Ceocm ic fo id ec a t i o n s
Nom. XXX velocity of prop. (NVP): 0.69 XXX Max. DC Resistance Unbal.: 5%
Length
copper CABLES
P E rlo ed ucc tt
Packaging
Max. XXXDC Resistance: 9.38 ohms/100 XXX m Mut. Capacitance @ 1 kHz: 46 pF/m
Max. Capacitance Unbal. (pair to ground): 131.2 pF/100m
21
Copper
Power Sum
Indoor
1061C 4-Pair Cable
copper CABLES
(contd)
22
Cable Contents Page
Frequency MHz
Attenuation Max. dB/100m
Char. Impedance Ohms
Std CAT5 NEXT dB
NEXT 90th Perc. dB
0.064
-
125 ± 15
-
-
0.128
-
115 ± 15
-
-
0.256
-
110 ± 15
-
-
0.772
1.8
105 ± 15
64
70
1
2.0
100 ± 15
62
68
4
4.1
100 ± 15
53
59
8
5.8
100 ± 15
48
54
10
6.5
100 ± 15
47
53
16
8.2
100 ± 15
44
50
20
9.3
100 ± 15
42
48
25
10.4
100 ± 15
41
47
31.25
11.7
100 ± 15
39
45
62.5
17.0
100 ± 15
35
41
100
22.0
100 ± 15
32
38
Product
Comcode
Length
Packaging
Colour
1061004CSL
106836950
305m (1000ft)
WE TOTE Box
Slate
1061004CSL
106836968
1340m (4400ft)
Reel
Slate
1061004CBK
107509051
305m (1000ft)
WE TOTE Box
Black
1061004CBL
106871809
305m (1000ft)
WE TOTE Box
Blue
1061004CBR
107328858
305m (1000ft)
Reel
Brown
1061004CGN
107244030
305m (1000ft)
WE TOTE Box
Spring Green
1061004CIV
106871817
305m (1000ft)
WE TOTE Box
Ivory
1061004CLL
107244022
305m (1000ft)
WE TOTE Box
Lilac
1061004COR
107193435
305m (1000ft)
Reel
Orange
1061004CRD
106926363
305m (1000ft)
WE TOTE Box
Red
1061004CWH
107147787
305m (1000ft)
WE TOTE Box
White
1061004CYL
107001687
305 m (1000ft)
WE TOTE Box
Yellow
Copper
Power Sum
Indoor
1061C 25-Pair Cable
Cable Contents Page
The 1061C 25-Pair Cable is composed of 24-AWG (0.5mm) bare solid-copper conductors insulated with high density polyolefin. The insulated conductors are tightly twisted into pairs, stranded into mini-units and jacketed with Avaya’s specially formulated OPTIFLEX-536 jacket. The cable employs a unique honeycomb core construction. This design consists of multiple 3 and 4-Pair tightly stranded sub-units. A total of seven unjacketed sub-units (six around one) are then stranded to comprise the cable core. This construction allows for easy pair identification and termination.
Figure 7 25-Pair Power Sum Cable
The 1061C 25-Pair is a high-speed, 100 ohm high performance cable with excellent Power Sum NEXT levels, which ensures that multiple identical or compatible signals can be shared in the same cable without loss of data integrity. 1061C provides excellent high speed transmission up to at least 155 Mb/s ATM and will support the mixing of multiple ATM signals along with other compatible signals (Please refer to the latest SYSTIMAX SCS Performance Specification for details concerning shared sheath compatibility). The 1061C 25-Pair Cables are UL Verified Category 5 standard 1061C 25-Pair Cables meet or exceed the Category 5 requirements in ISO/IEC 11801, CENELEC EN50173 and EIA/TIA 568A. Further, they are also UL Listed CMR and (UL) CMG for riser and general purpose use, and meet Listed
IEC 60332-3 Part C.
Gauge: 24 AWG
copper CABLES
Physical Specifications Weight: 168 kg/km
Outside Diameter: 13.0mm
Insulation Thickness: 0.22mm
Jacket Thickness: 0.506mm
Operating Temperature Range: -20 to 60ºC
Electrical Specifications Nom. velocity of prop. (NVP): 0.66
Max. DC Resistance: 9.38 ohms/100m
Max. DC Resistance Unbal.: 3%
Mut. Capacitance @ 1 kHz: 46 pF/m
Max. Capacitance Unbal. (pair to ground): 330 pF/100m
Max. DC Insulation Resistance: 150 MΩ/km
Dielectric Strength (Cond/Cond): 1.5 kV RMS for 2 sec, 2.5 kV DC for 2 sec Min. SRL (0 to 20 MHz): 23 dB
Min. SRL (20 to 100 MHz): 23-10*log(f/20)
23
Copper
Power Sum
Indoor
1061C 25-Pair Cable
copper CABLES
(contd)
24
Cable Contents Page
Frequency MHz
Attenuation Max. dB/100m
Power Sum NEXT Worst Pair dB
0.772
1.8
64
1
2.1
62
4
4.3
53
8
5.9
48
10
6.6
47
16
8.2
44
20
9.2
42
25
10.5
41
31.25
11.8
40
62.5
17.1
35
100
21.9
32
Product
Comcode
Length
Packaging
1061025CSL
107287484
305m (1000ft)
Reel
Copper
HeaderSum Power roman
Indoor
2061B Plenum 4-Pair Cable
Cable Contents Page
The 2061B 4-Pair Cable is composed of 24-AWG (0.5mm) bare solid-copper conductors insulated with Fluorinated-Ethylene-Propylene (FEP). The core of twisted pairs is jacketed with a low-smoke PVC. It conforms to the low-flame, low-smoke requirements of the NEC. The 2061B 4-Pair is a high-speed, 100 ohm high performance cable with excellent Power Sum NEXT levels which ensures that multiple identical or compatible signals can be shared in the same cable without loss of data integrity. 2061B provides excellent high speed transmission, is specified out to 155MHz and supports applications such as 155 Mb/s ATM, 622 Mb/s ATM and the proposed IEEE 802.3 1000Base-T (Gigabit Ethernet) Standard, Listed
using parallel transmission scheme technology in conjunction with other SYSTIMAX SCS components. 2061B Cables are UL Verified Category 5e standard 2061B Cables meet or exceed the Category 5 and Category 5e requirements in ISO/IEC 11801, CENELEC EN50173 and EIA/TIA 568A. 2061B Cables are UL Listed CMP (the best flame and smoke performance rating for LAN cables), and are listed in the Approved Fire and Security Products and Services list of the Loss Prevention Certification Board (UK).
Physical Specifications Gauge: 24 AWG
Weight: 28.6kg/km
Outside Diameter: 5.1mm
Insulation Thickness: 0.16mm
Jacket Thickness: 0.51mm
Max. Pulling Tension: 11.4kg
Breaking Pulling Tension: 41kg
Operating Temperature Range: -20 to 60ºC
Electrical Specifications Nom. velocity of prop. (NVP): 0.73
Max. DC Resistance: 9.38 ohms/100 m
Max. DC Resistance Unbal.: 5%
Mut. Capacitance @ 1 kHz: 46 pF/m
Max. Capacitance Unbal. (pair to ground): 131.2 pF/100m
Attenuation Max. dB/100m
Char. Impedance Ohms
P-P Next dB
0.772
5.5
105 ± 15
64
1
6.3
100 ± 15
62
4
13
100 ± 15
53
8
18
100 ± 15
48
10
20
100 ± 15
47
16
25
100 ± 15
44
20
28
100 ± 15
42
25
32
100 ± 15
41
31.25
36
100 ± 15
40
62.5
52
100 ± 15
36
100
67
100 ± 15
32
copper CABLES
Frequency MHz
Product
Comcode
Length
Packaging
Colour
2061004BWH
106939317
305m (1000ft)
Reel
White
2061004BWH
106939325
305m (1000ft)
WE TOTE
White
25
Copper
Power Sum
Indoor
3061 Low Smoke Zero Halogen Cables
Cable Contents Page
The 3061A is a Low Smoke Zero Halogen (LSZH) 4-Pair Cable. It is composed of 0.511mm (24-AWG) bare solidcopper conductors insulated with high density polyethylene non-halogen compound. The insulated conductors are tightly twisted into pairs and jacketed with the low smoke non-halogen compound. The 3061A LSZH Cable is IEC tested for low smoke and non-halogen emission and passes the following tests: Figure 8
- IEC 754 part 2, Non-halogen based on pH and
3061A Low Smoke Zero Halogen
Conductivity Measurements
4-Pair Cable
- IEC 1034 part 2, Smoke emission - IEC 332 part 1, Flammability and Fire retardant (3051A) - IEC 332 part 3, Flammability and Fire retardant (3061A) - NES 713: Toxicity index The 3061A 4-Pair LSZH is a high-speed, 100 ohm high performance cable with excellent pair-to-pair NEXT levels. 3061A LSZH cable provide excellent high speed and error free transmission. These are specified out to 155MHz and support applications such as 155 Mb/s ATM, 622 Mb/s
Reel Packaging
Ethernet) standard, using parallel transmission scheme
4-Pair Cable
technology in conjunction with other SYSTIMAX SCS components. The 3061A LSZH 4-Pair Cable meet or exceed attenuation and NEXT requirements in ISO/IEC 11801
copper CABLES
(1995), CENELEC EN50173 (1995), and EIA/TIA 568A (1995) Horizontal Cable Section for Category 5e. Further, these cables are UL verified as Category 5e standard.
Physical Specifications Gauge: 24 AWG
Weight: 34.96 kg/km
Outside Diameter: 5.3mm
Insulation Thickness: 0.2mm
Jacket Thickness: 0.55mm
Max. Pulling Tension: 11kg
Breaking Pulling Tension: 41 kg
Operating Temperature Range: -20 to 60ºC
Electrical Specifications Listed
Nom. Velocity of Prop. (NVP): 0.67
Max. DC Resistance: 9.4 ohms/100m
Max. DC Resistance Unbal.: 3%
Mut. Capacitance @ 1 kHz: 46 pF/m
Max. Capacitance Unbal. (pair to ground): 330pF/100m
26
Figure 9
ATM and the proposed IEEE 802.3 1000Base -T (Gigabit
Copper
Power Sum
Indoor
3061 Low Smoke Zero Halogen Cables (contd) Frequency MHz
Attenuation Max. dB/100m
Worst P-P NEXT dB
Worst P-P NEXT 90th Perc. dB
0.772
1.8
64
70
1
2.0
62
68
4
4.1
53
59
8
5.8
48
54
10
6.5
47
53
16
8.2
44
50
20
9.3
42
48
25
10.4
41
47
31.25
11.7
39
45
62.5
17.0
35
41
100
22.0
32
38
Product
Comcode
Length
Pair Size
Packaging
Colour
3061A-004
107573537
305m (1000ft)
4
Reel
White
3061A-004
107573545
305m (1000ft)
4
We Tote Box
White
3061A-025
107754350
305m (1000ft)
25
Reel
White
Cable Contents Page
copper CABLES 27
Copper
Category 3 Cables
Indoor
1010 4-Pair Cable
Cable Contents Page
1010 4-Pair LAN Cable consists of 0.511 mm (24-AWG) solid-copper conductors insulated with colour-coded PVC. It is a general-purpose, high performance cable used in voice and Local Area Network applications, specified up to 16Mhz. Please refer to the SYSTIMAX SCS Performance Specifications for distances supported by various data applications. The 1010 4-Pair Cables meet or exceed attenuation and NEXT requirements in ISO/IEC 11801 (1995), CENELEC EN50173 (1995), and EIA/TIA 568A (1995) Horizontal Cable Section for Category 3. Further, these cables are UL certified Listed
Figure 10
as Category 3, and UL listed MPR/CMR.
1010 4-Pair Cable
Physical Specifications Gauge: 24 AWG
Weight: 27.5 kg/km
Outside Diameter: 4.6mm
Insulation Thickness: 0.18mm
Jacket Thickness: 0.53mm
Max. Pulling Tension: 11kg
Breaking Pulling Tension: 33kg
Operating Temperature Range: -20 to 50ºC
copper CABLES
Electrical Specifications
28
Char. Imp. (1 to 16 MHz): 100 ± 15Ω
Nom. Velocity of Prop. (NVP): 0.67
Max. DC Resistance: 9.4 ohms/100m
Max. DC Resistance Unbal.: 5%
Mut. Capacitance @ 1 kHz: 59 pF/m
Max. Capacitance Unbal. (pair to ground): 3.28 pF/m
Frequency MHz
Attenuation dB/100m
Worst P-P NEXT dB @ 300m (1000ft)
0.064
0.75
–
0.256
1.11
–
0.512
1.6
–
0.772
1.96
43
1
2.3
42
4
4.9
34
8
7.54
32
10
8.5
31
16
11.5
28
Product
Comcode
Length
Packaging
1010004AGY
106062524
305m (1000ft)
WE TOTE Box
Copper
Category 3 Cables
Indoor
1010 MultiPair Cable
Cable Contents Page
1010 Multipair LAN Cable consists of 0.511mm (24-AWG) solid-copper conductors insulated with colour-coded PVC. It is a general-purpose, high performance cable used in voice and Local Area Network applications specified up to 16 MHz. Please refer to SYSTIMAX SCS Performance Specifications Listed
for distances supported by various data applications. The 1010 Multipair Cables meet or exceed attenuation and NEXT requirements in ISO/IEC 11801 (1995), CENELEC EN50173 (1995), and EIA/TIA 568A (1995) “Commercial Building Wiring Standard“ Riser Cable Section for Category
Figure 11
3. Further, these cables are UL listed MPR/CMR for riser or
1010 100-Pair Cable
general purpose use.
Physical Specifications Gauge: 24 AWG
Insulation Thickness: 0.20mm
Jacket Thickness: 0.76mm
Breaking Pulling Tension: 4 kg/cond.
Operating Temperature Range: -20 to 60ºC
Electrical Specifications Nom. Velocity of Prop. (NVP): 0.67
Max. DC Resistance: 9.4 ohms/100m
Max. DC Resistance Unbal.: 5%
Mut. Capacitance @ 1 kHz: 59 pF/m
Max. Capacitance Unbal. (pair to ground): 3.28 pF/m
Attenuation Max. dB/100m
Power Sum NEXT Worst Pair db
0.772
2.2
43
1
2.6
41
4
5.6
32
8
8.5
28
10
9.8
26
16
13.1
23
Product
Comcode
Pair Size
Weight (kg/km)
O.D
Length
Packaging
1010025AGY
106824329
25
142.7
10.2mm
305m (1000ft)
Reel
1010050AGY
106824378
50
283.0
13.7mm
305m (1000ft)
Reel
100
539.1
18.5mm
305m (1000ft)
Reel
10100100AGY 106824469
copper CABLES
Frequency MHz
29
Copper
Category 3 Cables
Indoor
2010 Cable
Cable Contents Page
The 2010 Plenum cable is comprised of a 24 AWG twisted-pair copper conductors individually insulated with various PVC compounds and sheathed with a white low smoke PVC outer jacket. It is a generalpurpose, high performance cable used in voice and Local Area Network applications. It can be used in air-handling plenums or above suspended ceilings without the use of conduits.
Electrical Specifications DC Resistance: 28.6 ohm/km maximum Resistance Unbalance: 3% maximum Mutual Capacitance @ 1kHz: 5.2nF/100m pair to ground Capacitance Unbalance: 328pF/100m pair to ground Nom. Velocity of Prop (NVP): 0.70 Characteristic Impedance: @ 0.772 MHz: 105 +/- 15 ohm Characteristic Impedance: @ 1.0 – 16.0 MHz: 100 + / - 15 ohm Att @ 1.0, 10, and 16 MHz: 7dB , 26dB and 35dB maximum / 100m
copper CABLES
NEXT @ 1.0, 10 and 16 MHz: 41dB, 26dB and 23dB minimum
30
Product
Comcode
Pair Size
Length
O.D.
Packaging
2010004BWH
107078396
4
305m (1000ft)
4.6mm
Reel
2010025BWH
107765992
25
305m (1000ft)
12.0mm
Reel
2010050BWH
107766040
50
305m (1000ft)
16.0mm
Reel
2010100BWH
107766057
100
305m (1000ft)
21.4mm
Reel
Copper
Category 3 Cables
Indoor
3010 LSZH Cable
Cable Contents Page
The 3010 LSZH is a Low Smoke, Zero Halogen cable that provides excellent flame retardance. It is composed of 0.511mm (24-AWG) solid copper conductors. It is a general-purpose, high performance cable used in voice and Local Area Network applications specified up to 16 Mhz. The 3010 LSZH Cable is IEC tested for low smoke and non-halogen emission and passes the following tests: - IEC 754 part 2, Non-halogen based on pH and Conductivity Measurements - IEC 1034 part 2, Smoke emission - IEC 332 part 1, Flammability and Fire retardant (3051A) - IEC 332 part 3, Flammability and Fire retardant (3061A) - NES 713: Toxicity index
Electrical Specifications DC Resistance: 93.8 ohm/km maximum Resistance Unbalance: 3% maximum Mutual Capacitance @ 1kHz: 66 nF/km maximum pair to ground Capacitance Unbalance: 3400pF/km maximum pair to ground Nom. Velocity of Prop. (NVP): 0.6 Characteristic Impedance: 100 ohms ±15% @ 1.0MHz -16MHz Att @ 1.0, 10 and 16 MHz: 2.6dB, 9.8 dB and 13.1dB maximum /100m SRL @ 1.0, 10 and 16 MHz: 12dB, 10 dB and 10dB minimum NEXT @ 1.0, 10 and 16 MHz: 41dB, 26dB and 23dB minimum
Product
Comcode
Pair Size
Length
O. D.
Packaging
3010LSZH
977700001
25
305m (1000ft)
12.7mm
Reel
3010LSZH
977700004
100
305m (1000ft)
25.6mm
Reel
copper CABLES 31
Copper
Category 3 Cable
Indoor
Cross Connect Wire
Cable Contents Page
CCW-F Cross-Connect Wire is used for cross connecting voice or data circuits running at 10 Mb/s or less on 110 cross-connect hardware. It consists of solid annealed copper conductors individually insulated with PVC. Listed
The insulated pairs are colour coded for identification.
Figure 12 CCW-F 2/24 Cross-Connect Wire Reel
Physical Specifications Gauge: 24 AWG (0.511mm)
Outside Diameter: 0.97mm max
Operating Temperature: 75ºC max
Insulation Thickness: 0.20mm
Electrical Specifications
copper CABLES
DC Resistance: 17.1 (Ω/100m)
32
Mutual Capacitance: 4.9 nF/100m max.
Product
Comcode
Pair Size
Length
Packaging
Colour
CCW-F 1/24
105597199
1
305m (1000ft)
Reel
Y-BL/BL-Y
CCW-F 2/24
105597413
2
320m (1050ft)
Reel
BL-R,R-O
CCW-F 3/24
105597462
3
201m (660ft)
Reel
W-BL,W-O,W-G
CCW-F 4/24
105597512
4
305m (1000ft)
Reel
W-BL,O,G,BR
Copper
Power Sum
Outdoor
Outside Plant Cables
Cable Contents Page
Avaya’s Power Sum Outside Plant Cable is for use in an outdoor environment. This 4-pair cable was developed for high-speed applications requiring state of the art electrical performance in an environmentally robust package. As a component in the SYSTIMAX® SCS product family, system performance is tested and guaranteed for all Category 5 applications. The cable was developed for use in the outdoor environment and is a filled design to be used in wet locations. It can be used with Category 5 protectors in exposed locations. These protectors have been specially developed for Category 5 data applications, and should not be used for voice applications. Standard telephony protection devices do not provide adequate protection or electrical performance to meet rigid Category 5 horizontal electrical requirements, and cannot be used in Category 5 applications. Standard 110ANA1 protection devices can be used for voice circuits in exposed locations. Power Sum Outside Plant Cable installations must meet all ISO/IEC 11801 requirements for a horizontal link. No more than 4 connections are allowed, including the protection devices at each end. Each protector counts as one of the four connections. Total cable length is limited to 90 metres (295ft.) Listed
for a Category 5 operation.
Physical Specifications Gauge: 24AWG Weight: 49Kg/Km Outside Diameter: 0.21mm Operating Temperature Range: -20 to 60ºC Sheath Material: LDPE Conductor Insulation Material: LDPE Core: Filled
Electrical Specifications copper CABLES
Mutual Capacitance Nom.: 17.07 pF/ft. (56 pF/m) Characteristic Impedance (1-100MHz): 100 ±15 ohms DC Resistance Max.: 28.6 Ohms/1000ft. (9.4 Ohms/100m)
33
Copper
Power Sum
Outdoor
copper CABLES
Outside Plant Cables (contd)
34
Frequency (MHz)
Attenuation (dB/100m)
Power Sum Near End Crosstalk (dB)
Structural Return Loss (dB)
ACR (dB/90m)
0.772
1.8
64
23
62.4
1
2.0
62
23
60.2
4
4.1
53
23
49.3
8
5.8
49
23
43.8
10
6.5
47
23
41.2
16
8.2
44
23
36.6
20
9.3
42
23
33.6
25
10.4
41
22
31.6
31.25
11.7
39
21
28.5
62.5
17
35
18
19.7
100
22
32
16
12.2
Product
Comcode
Length
Pair Size
Package
CA 3-NCA4158 4/24 R1000
108257643
305m (1000ft)
4
Reel
Cable Contents Page
Copper
ASP Filled Core Cable
Outdoor
ANMW Cable
Cable Contents Page
The ASP-Filled Core Cable has an Aluminium Steel with Polyethylene (ASP) sheath and a core of solid-copper conductors, dual insulated with foam skin and plastic, and surrounded by a gel filling compound. The core is surrounded by a plastic core wrap and armoured with corrugated aluminium and steel. Additional filling compound is found between the core wrap and the armour. The outer jacket is polyethylene. ASP cable is used for direct-buried applications where wet or moist soil conditions threaten electrical performance. ASP is also the preferred sheath for mechanical and wildlife protection.
Figure 13
This cable is for outside plant use only and not intended
ANMW-200 Cable
for use inside buildings unless enclosed in a metallic or fire retardant conduit. ASP-Filled Core Cables meet or exceed attenuation and NEXT requirements in ISO/IEC 11801 (1995), and EIA/TIA 568A (1995) Campus backbone application for Category 3.
Physical Specifications Gauge: 24AWG
Electrical Specifications Max. DC Resistance: 8.96ohms/100m
Mutual Capacitance @ 1kHz: 5.15nF/100m
Impedance: 100 Ω (25-pair)
Attenuation @ 772 kHz: 1.83 dB/100m (25-pair) Attenuation @ 1.0 MHz: 2.1dB/100m (25-pair)
Comcode
Pair Size
Weight (kg/km)
O.D.
Length
Packaging
ANMW
106583909
25
330
15.5mm
305m (1000ft)
Reel
ANMW
106583917
50
520
19.6mm
305m (1000ft)
Reel
ANMW
106583933
100
880
24.1mm
305m (1000ft)
Reel
copper CABLES
Product
35
Fibre
LazrSPEED™
Indoor
Fibre Description The LazrSPEED Solution is the first “next generation” multimode fibre designed to support 10 Gb/s distances of up to 300 metres using serial 850 nm electronics. Designed to exceed standards requirements at 1300 nm as well, it offers unparalleled versatility and legacy application support. A dual coating applied over the glass surface protects the fibre and enhances its long-term reliability. Each fibre is proof tested to 100 kpsi so that it will survive installation loads and associated long-term residual stresses, even under extreme environmental conditions. Benefits – 10 Gb/s using 850 nm VCSELs to 300 m – Dual wavelength capability for increased versatility – Excellent dimensional properties for low loss connectorisation – Legacy support: Ethernet, Fast Ethernet, Token Ring, ATM, FDDI – Dual coating for excellent environmental performance and long-term reliability – Excellent resistance to bending-induced losses – Compliant with IEC 60793 and EIA/TIA 492 specifications – 500/500 MHz.km overfilled bandwidth While offering unparalleled LASER bandwidth, LazrSPEED fibre also complies with IEC 60793 and EIA/TIA 492 specifications. LazrSPEED fibre has a LASER bandwidth of 2000/500 MHz.km making it the ideal media for cost effective migration to 10 Gb/s applications.
Physical Specifications
fibre CABLES
Core diameter: 50 µm ± 2 µm
Core Non-Circularity: <6%
Core/Cladding Concentricity Error: <3.0 µm
Cladding Diameter: 125 µm ± 1 µm
Cladding Non-Circularity: <2.0%
Coloured Fibre Diameter: 250 µm ± 15 µm
Coating Diameter (uncoloured): 245 ± 10 µm
Coating/Cladding Concentricity Error: ≤ 12 µm
Proof Test Levels: 0.7GPa minimum
Fibre Curl: ≥ 2 m
Operating Temperature Range: -60 to 85ºC
Minimum Tensile Strength: 100,000 psi
Optical Specifications Maximum Fibre Loss:
3.5 dB/km at 850 nm
Minimum Bandwidth:
500 MHz at 850 nm (overfilled)
1.5 dB/km at 1300 nm 500 MHz at 1300 nm (overfilled) 2000 MHz at 850 nm (laser) 500 MHz at 1300 nm (laser) Numerical Aperture:
0.200 +0.015/-0.010
Nominal Refraction Index difference bw Peak of Core and Cladding: 1.0% Effective Group Index of Refraction @ 850 nm: 1.482 Effective Group Index of Refraction @ 1300 nm: 1.477 Point Discontinuities @ 850 nm and 1300 nm: <0.2 dB
36
Cable Contents Page
Fibre
LazrSPEED
Indoor
Indoor Multimode Low Smoke Zero Halogen Cable
Cable Contents Page
The LazrSPEED Solution supports 10 Gb/s speeds at distances up to 300 metres, using single channel 850 nm VCSEL electronics. The LazrSPEED channel provides the lowest loss and highest bandwidth solution. Features: - 10 Gigabit/Second connectivity - Legacy support: Ethernet, Fast Ethernet, Gigabit Ethernet, Token Ring, ATM, FDDI - Aqua colour coded solution for ease of craft identification Figure 14
- LSZH cable for use in both riser and
LazrSPEED Cable
horizontal applications - LazrSPEED fibre has a LASER bandwidth of 2000/500MHz.km, making it the ideal media for cost-effective migration to 10 Gb/s applications For LazrSPEED optical fibre specification refer to page 36.
Physical Specifications Maximum Nominal Length: 4km
Buffering: 900 µm
Cable Minimum Bending Radius:
Max. Pulling Tension: 90kg
During Installation: 20x cable diam.
Operating Temperature Range: 0 to 50ºC
After Installation: 10x cable diam.
Storage Temperature Range: -40 to 70ºC
Buffered Fibre minimum Bend Radius: 19mm
Comcode
Fibre Count
Fibre Type
Packaging
BC-002D-ZHX
700009863
2
LZ
Reel
BC-004D-ZHX
700009822
4
LZ
Reel
BC-006D-ZHX
700009780
6
LZ
Reel
BC-012D-ZHX
700009749
12
LZ
Reel
BC-024D-ZHX
700009707
24
LZ
Reel
fibre CABLES
Product
37
Fibre
OptiSPEED™
Indoor
Multimode Fibre Description The OptiSPEED multimode fibre is a graded index 62.5 Micron fibre optimised for operation at 850 and 1300 nm. It uses a carefully controlled refractive index profile to achieve low attenuation and high bandwidth at both operating wavelengths. A dual coating applied over the glass surface protects the fibre and enhances its long-term reliability. Each fibre is proof tested to 100 kpsi so that it will survive installation loads and associated long-term residual stresses, even under extreme environmental conditions. Benefits – Dual wavelength capability for increased versatility – Excellent dimensional properties for low loss connectorisation – Supports Ethernet, Fast Ethernet, Token Ring, ATM, FDDI – Dual coating for excellent environmental performance and long-term reliability – Excellent resistance to bending-induced losses – Compliant with IEC 60793 and EIA/TIA 492 specifications – 200/500 MHz.km overfilled bandwidth
Physical Specifications Core Diameter: 62.5 ± 3.0µm Core Non-circularity: 6% max. (typical < 2%) Core/Clad Concentricity Error: ≤ 3.0µm Cladding Diameter: 125.0 ± 2.0µm Cladding Non-circularity: ≤ 2% Coating Diameter (uncoloured): 245 ± 10µm Coating/Cladding Concentricity Error: ≤ 12 µm Proof Test Levels: 0.7GPa minimum Fibre Curl: ≥ 2 m
fibre CABLES
Operating Temperature Range: -60 to 85ºC
Optical Specifications Maximum Fibre Loss @850 nm: 3.4 dB/km (typical range 2.8 to 3.2 dB/km) Maximum Fibre Loss @1300 nm: 1.0 dB/km (typical range 0.5 to 0.8 dB/km) Minimum Bandwidth @850 nm: 200 MHz.km Minimum Bandwidth @1300 nm: 500 MHz.km Numerical Aperture: 0.275 ± 0.015 Nominal Refraction Index Difference bw peak of Core and Cladding: 2.0% Effective Group Index of Refraction @ 850 nm: 1.496 Effective Group Index of Refraction @ 1300 nm: 1.491 Point Discontinuities @ 850 and 1300 nm: < 0.2 dB
38
Cable Contents Page
Fibre
OptiSPEED
Indoor
Singlemode Fibre Description
Cable Contents Page
Dispersion Unshifted fibres (EIA/TIA Class IVa) with matched cladding are offered for optimised system operation in the 1310 nm window. All Avaya Singlemode Fibres are manufactured to meet a low polarisation mode dispersion (PMD) specification in cable. Avaya Depressed Cladding Singlemode Fibre consists of a germanium doped core with two concentric synthetic silica cladding layers. The inner cadding is doped with fluorine to lower its refractive index relative to outer layers. This design results in a smaller mode field diameter for improved microbending and macrobending peformance. The dispersion characteristics of the fibre are optimized for operating in the 1310nm region although 1550 nm is possible.
Physical Specifications Cladding Diameter: 125.0 ± 1.0µm Cladding Non-Circularity: < 1.0% Coloured Fibre Diameter: 250 ± 15µm Core Diameter: 8.3µm Core/Cladding Concentricity Error: 0.8µm Minimum Proof Strength: 0.70 Gpa (100kpsi) Fibre Curl: > 2m Fibre Macrobend (100 turns, 75 mm diameter): 0.05dB @ 1310nm 0.10dB @ 1550nm Fibre Macrobend (1 turn @ 32mm diameter): 0.5dB @ 1550 nm Coating Strip Force: 1.3 N< F< 8.9 N Dynamic Tensile Strength(Unaged): >550kpsi (3.8 GPa) Dynamic Tensile Strength(Aged): >440kpsi (3.0 GPa) Dynamic Fatigue: >20 Static Fatigue: >20
Optical Specifications Difference in Index of Refraction(Depressed Clad): 0.37% Mode Field Diameter(Depressed Clad): 8.8± 0.5µm @ 1310 nm
fibre CABLES
Attenuation: 0.4 dB/km @ 1310nm 0.3 dB/km @ 1550nm Attenuation at Water Peak: 2.0 dB/km @ 1385 nm Point Discontinuities: 0.1 dB Zero-Dispersion Wavelength (Depressed Clad): 1310 ± 10 nm Zero-Dispersion Slope: 0.092 ps/nm2-km Maximum Dispersion (Depressed Clad): 2.8 ps/nm-km 1285 to 1330nm Polarisation Mode Dispersion Coefficient (Avaya Cable): 0.5 ps/km @ 1310 nm Fibre Cutoff Wavelength (Matched Clad): 1130 nm, 1300nm Cable Cutoff Wavelength: < 1260 nm
39
Fibre
OptiSPEED
Indoor
Indoor Multimode Low Smoke Zero Halogen Building Cable
Cable Contents Page
The OptiSPEED Low Smoke Zero Halogen (LSZH) Building Cable consists of 1, 2, 4, 6, 8, or 12 individual fibres in either OptiSPEED Multimode, or OptiSPEED Singlemode. Each 125-micron fibre has a specially formulated dual 100 coating, bringing the diameter to 250 microns, and is proof tested at 100 kpsi. The coated fibre is buffered to 900 microns with ethylene copolymer with a non-halogen mineral filler. The buffer is colour coded for identification. The buffered fibres are surrounded by halogen free aramid yarn for strength and over jacketed with ethylene copolymer for protection. The jacket colour of the multimode high-fibre count LSZH
Figure 15
OptiSPEED Cables is orange.
OptiSPEED Cable
The LSZH cable passes the following tests: - IEC 754 part 2, Acidity/corrosively based on pH and conductivity measurements - IEC 1034 part 2, Smoke emission - IEC 332 part 3, Flammability and Fire retardant Figure 16
- NES 713, Toxicity index
OptiSPEED Cross Section
OptiSPEED LSZH cables meet or exceed all standards established or proposed for LAN, premises or intra building cables such as ISO/IEC 11801, CENELEC EN50173 and EIA/TIA568A. For OptiSPEED MM Optical Fibre specifications refer to page 38.
fibre CABLES
Physical Specifications Maximum Nominal Length: 4km
Buffering: 900 µm
Cable Minimum Bending Radius:
Max. Pulling Tension: 90kg
During Installation: 20x cable diam.
Operating Temperature Range: 0 to 50ºC
After Installation: 10x cable diam.
Storage Temperature Range: -40 to 70ºC
Buffered Fibre Minimum Bend Radius: 19mm
40
Product
Comcode
Fibre Count
We i g h t (kg/km)
O.D.
Fibre Ty p e
Length
Packaging
LGBC-002D-LHO
700008485
2
16.69
3.96mm
OS MM
610m (2000ft)
Reel
LGBC-004D-LHO
700008477
4
19.37
4.39mm
OS MM
610m (2000ft)
Reel
LGBC-006D-LHO
700008469
6
25.63
5.0mm
OS MM
610m (2000ft)
Reel
LGBC-008D-LHO
700008451
8
29.36
5.41mm
OS MM
610m (2000ft)
Reel
LGBC-012D-LHO
700008444
12
35.77
6.05mm
OS MM
610m (2000ft)
Reel
CA-LG-BLDGABC-006-SHX
700012057
6
25.63
5.0mm
OS SM
610m (2000ft)
Reel
CA-LG-BLDGABC-008-SHX
700012065
8
29.36
5.41mm
OS SM
610m (2000ft)
Reel
CA-LG-BLDGABC-012-SHX
700012073
12
35.77
6.05mm
OS SM
610m (2000ft)
Reel
Fibre
OptiSPEED
Indoor
High Fibre Count Building Cable
Cable Contents Page
Indoor OptiSPEED HFC Building Cables consists of 24, 36, 48 and 72 individual OptiSPEED Multimode fibres, each with a colour coded PVC buffer. The buffered fibres are organised in subunits of 6 fibres, reinforced with Aramid Yarn for superior strength and surrounded with a colour-
Figure 17
coded PVC tube for easy installation. The OptiSPEED HFC
OptiSPEED
Cables do not have metallic elements nor do they have cen-
High Fibre Count
tral strength members. It’s not part of the Low Smoke Zero
Cable Cross Section
Halogen family. Most applications for this high fibre count cable will be in the riser or backbone. It may not be used in the distribution or horizontal and each 6 fibre subunit may be split out in the work area. The jacket colour of the high fibre count cables for multimode is grey and singlemode is yellow. For OptiSPEED MM specifications refer to page 38. For OptiSPEED SM specifications refer to page 39. OptiSPEED HFC Cables meet or exceed all standards established or proposed for LAN, premises or intra building cables such as ANSI-FDDI, EIA/TIA 568A, Listed
ISO/IEC IS11801 and CENELEC EN50173.
Physical Specifications Maximum Nominal Length: 2km
Buffering: 900 µm
Cable Minimum Bending Radius:
Max. Pulling Tension: 226kg
During Installation: 20x cable diam.
Operating Temperature Range: -20 to 70ºC
After Installation: 10x cable diam.
Storage Temperature Range: -40 to 70ºC
Buffered Fibre Minimum Bend Radius: 19mm
Comcode
Fibre Count
We i g h t (kg/km)
O.D.
Fibre Ty p e
Length
Packaging
LGBC-024D-LHO
700009293
24
180
14.4mm
OS MM
3660m (12000ft)
Reel
LGBC-036D-LHO
700009194
36
186
14.4mm
OS MM
3660m (12000ft)
Reel
LGBC-048D-LHO
700009087
48
235
14.4mm
OS MM
3660m (12000ft)
Reel
LGBC-072D-LHO
700009012
72
249
20.4mm
OS MM
3660m (12000ft)
Reel
CALG-BLDGABC-024D-SHX
700012131
24
180
14.4mm
OS SM
610m (2000ft)
Reel
CALG-BLDGABC-036D-SHX
700012141
36
186
14.4mm
OS SM
610m (2000ft)
Reel
CALG-BLDGABC-048D-SHX
700012156
48
235
14.4mm
OS SM
610m (2000ft)
Reel
CALG-BLDGABC-072D-SHX
700012164
72
249
20.4mm
OS SM
610m (2000ft)
Reel
fibre CABLES
Product
41
Fibre
OptiSPEED
Indoor
Indoor Plenum Building Cable
Cable Contents Page
The OptiSPEED Plenum Building Cable consists of 1, 2, 4, 6, 8, or 12 individual OptiSPEED Multimode fibres. Each 125 micron fibre has a specially formulated Dual 100 coating, bringing the diameter to 250 microns, and is proof tested at 100 kpsi. The buffer is colour coded for identification. The buffered fibres are surrounded by Aramid Yarn for strength and over jacketed with a low-smoke, flame-retardant plenum jacket for protection. The jacket is white in colour. For OptiSPEED MM specifications refer to page 38. For OptiSPEED SM specifications refer to page 39. OptiSPEED Plenum Cables meet or exceed all standards established or proposed for LAN, premises or Listed
intra-building cables such as ANSI-FDDI, EIA/TIA 568A, ISO/IEC 11801 and CENELEC EN50173.
Physical Specifications Maximum Nominal Length: 4km
Buffering: 900 µm
Cable Minimum Bending Radius:
Max. Pulling Tension: 90kg
During Installation: 20x cable diam.
Operating Temperature Range: -40 to 85ºC
After Installation: 10x cable diam.
Storage Temperature Range: -40 to 85ºC
fibre CABLES
Buffered Fibre Minimum Bend Radius: 19mm
42
Product
Comcode
Fibre Count
We i g h t (kg/km)
O.D.
Fibre Ty p e
Length
Packaging
LGBC-002D-LPX
700009657
2
14.1
3.9mm
OS MM
610m (2000ft)
Reel
LGBC-004D-LPX
700009582
4
19.5
4.6mm
OS MM
610m (2000ft)
Reel
LGBC-006D-LPX
700009517
6
22.0
4.7mm
OS MM
610m (2000ft)
Reel
LGBC-008D-LPX
700009442
8
25.6
5.1mm
OS MM
610m (2000ft)
Reel
LGBC-012D-LPX
700009392
12
30.5
5.7mm
OS MM
610m (2000ft)
Reel
Fibre
LazrSPEED™
Outdoor
Outside Plant Cable (Dielectric Cable)
Cable Contents Page
The LazrSPEED Solution supports 10 Gb/s speeds at distances up to 300 metres, using single channel 850 nm VCSEL electronics. The LazrSPEED channel provides the lowest loss and highest bandwidth solution. For LazrSPEED fibre specifications refer to page 36. DNX cable is the standard Non-Metallic (Dielectric) cable. Features: - 10 Gigabit/Second connectivity - Legacy support: Ethernet, Fast Ethernet, Gigabit Ethernet, Token Ring, ATM, FDDI - Aqua colour coded solution for ease of craft identification - Distribution Apparatus designed for enterprise applications - Low loss LC connector provides high density with industry best performance - Hybrid patch cords for equipment interconnects
Physical Specifications Weight: 45kg/km
Outside Diameter: 7.6mm
Colour: Black
Maximum Nominal Length: 4.4km
Cable Minimum Bending Radius:
Operating Temperature Range: -40 to 70ºC
Under Load: 20x cable diam.
Max. Pulling Tension: 275kg
Under no Load: 10x cable diam.
Comcode
Fibre Count
Fibre Type
Packaging
LDNX-006-HXG
700012347
06
LZ
Reel
LDNX-012-HXG
700012354
12
LZ
Reel
LDNX-024-HXG
700012362
24
LZ
Reel
LDNX-048-HXG
700012370
48
LZ
Reel
LDNX-096-HXG
700012388
96
LZ
Reel
fibre CABLES
Product
43
Fibre
OptiSPEED™
Outdoor
DSX Metallic Cable
Cable Contents Page
DSX is the standard Fibre Optic Express Entry (LXE) Cable containing either OptiSPEED Multimode or OptiSPEED Singlemode fibre. Composite cables (a mix of Singlemode and Multimode) are also available upon request. The cable is designed for easy mid-sheath entry. The fibres are separated into binder groups surrounded by a plastic cone. The steel armour provides rodent and lightning protection. The sheath jacket material is high-density polyethylene for maximum environmental protection and is petrochemical stable. The DSX Cable can be used in underground conduit, direct-buried, or aerial applications. These cables are black
Figure 18
in colour.
3DSX Cable
For OptiSPEED MM specifications refer to page 38. For OptiSPEED SM specifications refer to page 39. DSX Cables meet or exceed all LAN/Cabling standards established or proposed for campus cables such as Listed
EIA/TIA 568B, ISO/IEC 11801 and CENELEC EN50173. Figure 19 3DSX Cross Section
Physical Specifications Maximum Nominal Length: 6km Cable Minimum Bending Radius:
Operating Temperature Range: -40 to 70ºC
Under no Load: 10x cable diam.
Max. Pulling Tension: 275kg
fibre CABLES
Under Load: 20x cable diam.
44
Product
Comcode
Fibre Count
We i g h t (kg/km)
O.D.
Fibre Ty p e
Length
Packaging
3DSX-006-HXM
700010614
6
160
11.4mm
OS MM
610m (2000ft)
Reel
3DSX-008-HXM
700010606
8
160
11.4mm
OS MM
610m (2000ft)
Reel
3DSX-012-HXM
700010598
12
160
11.4mm
OS MM
610m (2000ft)
Reel
3DSX-024-HXM
700010580
24
160
12.4mm
OS MM
610m (2000ft)
Reel
3DSX-036-HXM
700010572
36
180
13mm
OS MM
3660m (12000ft)
Reel
3DSX-048-HXM
700010564
48
180
13mm
OS MM
3660m (12000ft)
Reel
3DSX-072-HXM
700010580
72
216
15.5mm
OS MM
3660m (12000ft)
Reel
4DSX-006-BXD
700032865
6
130
11.4mm
OS SM
610m (2000ft)
Reel
4DSX-008-BXD
700032873
8
130
11.4mm
OS SM
610m (2000ft)
Reel
4DSX-012-BXD
700012230
12
130
11.4mm
OS SM
610m (2000ft)
Reel
4DSX-024-BXD
700012248
24
130
11.4mm
OS SM
610m (2000ft)
Reel
4DSX-036-BXD
700012255
36
180
13.0mm
OS SM
610m (2000ft)
Reel
4DSX-048-BXD
700012263
48
180
13.0mm
OS SM
610m (2000ft)
Reel
4DSX-072-BXD
700012271
72
180
13.0mm
OS SM
610m (2000ft)
Reel
Fibre
OptiSPEED
Outdoor
DNX Non-Metallic Cable
Cable Contents Page
DNX OptiSPEED Cable is the standard Non-Metallic (Dielectric) Lightguide Express Entry (LXE) cable, containing OptiSPEED Multimode fibre. Composite cables are also available upon request. It is designed for easy mid-sheath entry. Fibres are separated into colour-coded binder groups surrounded by a core tube filled with waterblocking compound. DNX Cable is used in underground conduit, direct-buried, or aerial applications The LXE sheath has non-metallic strength members parallel to the core and outside the core. The sheath jacket material
Figure 20
is high-density polyethylene for maximum environmental
3DNX Cable
protection and is petrochemical stable. These cables are black in colour. For OptiSPEED MM specifications refer to page 38. For OptiSPEED SM specifications refer to page 39. DNX cables meet or exceed all LAN/Cabling standards established or proposed for campus cables such as
Figure 21
EIA/TIA 568B, ISO/IEC 11801 and CENELEC EN50173.
3DNX Cross Section
Physical Specifications Maximum Nominal Length: 6km Cable Minimum Bending Radius:
Operating Temperature Range: -40 to 70ºC
Under no Load: 10x cable diam.
Max. Pulling Tension: 275kg
Under Load: 20x cable diam.
Comcode
Fibre Count
We i g h t (kg/km)
O.D.
Fibre Ty p e
Length
Packaging
3DNX-006-HXM
700010721
6
160
11.4mm
OS MM
610m (2000ft)
Reel
3DNX-008-HXM
700010713
8
160
11.4mm
OS MM
610m (2000ft)
Reel
3DNX-012-HXM
700010705
12
160
11.4mm
OS MM
610m (2000ft)
Reel
3DNX-024-HXM
700010689
24
160
11.4mm
OS MM
610m (2000ft)
Reel
3DNX-036-HXM
700010671
36
180
13.0mm
OS MM
610m (2000ft)
Reel
3DNX-048-HXM
700010663
48
180
13.0mm
OS MM
610m (2000ft)
Reel
3DNX-072-HXM
700010648
72
216
13.0mm
OS MM
610m (2000ft)
Reel
4DNX-006-BXD
700032899
06
160
11.4mm
OS SM
610m (2000ft)
Reel
4DNX-008-BXD
700032907
08
160
11.4mm
OS SM
610m (2000ft)
Reel
4DNX-012-BXD
700012289
12
160
11.4mm
OS SM
610m (2000ft)
Reel
4DNX-024-BXD
700012297
24
160
11.4mm
OS SM
610m (2000ft)
Reel
4DNX-036-BXD
700012305
36
180
13.0mm
OS SM
610m (2000ft)
Reel
4DNX-048-BXD
700012313
48
180
13.0mm
OS SM
610m (2000ft)
Reel
4DNX-072-BXD
700012321
72
216
15.5mm
OS SM
610m (2000ft)
Reel
fibre CABLES
Product
45
Fibre
OptiSPEED
Outdoor
DDX Non-Metallic Cable
Cable Contents Page
The 3DDX Cable is available with 2, 4, 6, 8, 12, or 18 fibres. The OptiSPEED multimode fibres are in a core. The fibres are colour coded and contained in a gel-filled, polypropylene tube. The tube is covered with a water blocking material and six non-metallic strength elements. Two diametrically opposed ripcords are added and a medium density polyethylene sheath is applied. This rugged design makes it suitable for underground, aerial, direct buried, tunnel, or tray installations. The 3DDX cable was specifically designed for use in crowded duct applications. It is ideally suited to connect equipment or facilities that are separated
Figure 21
by an outdoor type environment.
3DDX Cable
For OptiSPEED MM specifications refer to page 38. For OptiSPEED SM specifications refer to page 39. 3DDX Cables meet or exceed all LAN/Cabling standards established or proposed for campus cables such as ANSI-FDDI, EIA/TIA 568A ISO/IEC IS11801 and CENELEC EN50173.
Figure 23 3DDX Cross Section
Physical Specifications Weight: 45kg/km
Outside Diameter: 7.6mm
Colour: Black
Maximum Nominal Length: 4.4km
Cable Minimum Bending Radius:
Operating Temperature Range: -40 to 70ºC
Under Load: 20x cable diam.
Max. Pulling Tension: 275kg
fibre CABLES
Under no Load: 10x cable diam.
46
Product
Comcode
Fibre Count
Length
Fibre Type
Packaging
3DDX-002-HXM
700010796
2
610m (2000ft)
OS MM
Reel
3DDX-004-HXM
700010788
4
610m (2000ft)
OS MM
Reel
3DDX-006-HXM
700010770
6
610m (2000ft)
OS MM
Reel
3DDX-008-HXM
700010762
8
610m (2000ft)
OS MM
Reel
3DDX-012-HXM
700010754
12
610m (2000ft)
OS MM
Reel
3DDX-018-HXM
700010747
18
610m (2000ft)
OS MM
Reel
4DDX-004-BXD
700032774
4
610m (2000ft)
OS SM
Reel
4DDX-006-BXD
700032782
6
610m (2000ft)
OS SM
Reel
4DDX-008-BXD
700032790
8
610m (2000ft)
OS SM
Reel
4DDX-012-BXD
700032808
12
610m (2000ft)
OS SM
Reel
4DDX-018-BXD
700059470
18
610m (2000ft)
OS SM
Reel
Fibre
OptiSPEED
Outdoor
Loose Tube Cable
Cable Contents Page
Avaya also offers a full range of Loose Tube optic cable designs. These cables are available with OptiSPEED Multimode and OptiSPEED Singlemode. The fibres are placed within gel filled buffer tubes which are stranded around a centre member – either dielectric or steel – using the Reverse Oscillating Lay (ROL) stranding technique. This aids mid-span fibre access. Each tube can contain up to twelve fibres. A water blocking material is applied to the cable core region to prevent water migration inside the cable. Dual binder threads secure the core. A variety of sheaths are available to withstand the rigors of duct, buried and aerial installations. Full details of all designs may be obtained from your Avaya representative. All Dielectric Basic all-dielectric design suitable for multiple applications. Available with up to 288 fibres. Armoured Features corrugated steel tape and aramid yarns for extra strength and protection. Available with up to 240 fibres. ADSS Cable This All Dielectric Self-Supporting (ADSS) cable is ideal for aerial use in long spans up to 1000 metres. It is a popular design with electric utilities and alternate access providers because of the extra strength provided by the aramid yarns and the fact that it mounts directly onto existing poles and requires no pre-installed messenger (guide wire). Self-Supporting The Loose Tube Cable is available with up to 144 fibres non-armoured and 72 fibres armoured. It may be used for spans of up to 150 metres (500ft) under heavy loading conditions.
fibre CABLES 47
Fibre
OptiSPEED
Indoor/Outdoor
LSZH Fibre Optic Cable
Cable Contents Page
The Avaya Low Smoke Zero Halogen Fibre Optic Indoor/ Outdoor Cable is built to the International ISO/IEC specifications and features a Low Smoke Zero Halogen (LSZH) design. LSZH Fibre Optic Indoor/Outdoor Cable is a totally dry (jelly-free) and waterproof central core cable. It does not contain any gel, filling or flooding compound, grease or other flammable water blocking fluids. The UV protected Fibre Optic Indoor/Outdoor Cable is totally halogen free and flame retardant (self-extinguishing).
Figure 24
LSZH Indoor/Outdoor Cables use aramid yarns for
Dry Cable
LSZH Totally
strength and do not contain any stiff fibre glass rods or a central strength member. The aramid yarns are specially prepared with an agent that provides the waterproof attribute of the Indoor/Outdoor cables. The cables do not contain ripcords. Because of the use of buffered fibres rather than coated fibres, connectorisation does not require buffer tubing. The absence of gel, filling compound, flooding compound, grease or other flammable water blocking fluids further guarantee an easy and clean connectorisation process. Colour of the cable jacket is black. Each buffered fibre is colour coded - Blue, Orange, Green, Brown, Slate, White, Listed
Red, Black, Yellow, Violet, Rose, and Aqua. For OptiSPEED MM specifications refer to page 38. For OptiSPEED SM specifications refer to page 39.
fibre CABLES
Avaya’s Indoor/Outdoor Cables are SYSTIMAX SCS approved.
Physical Specifications Weight: 37kg/km Diameter: 6.4mm
48
Product
Comcode
Fibre Count
Fibre Type
Length
Packaging
LGIO-012B-LHX
700010390
12
OS MM
2000m (6560ft)
Reel
LGIO-024B-LHX
700008543
24
OS MM
2000m (6560ft)
Reel
LGIO-036B-LHX
700008519
36
OS MM
2000m (6560ft)
Reel
CLB-A10-012B-ZHX
700010119
12
OS MM
2000m (6560ft)
Reel
CLB-A10-012B-SHX
700012107
12
OS SM
2000m (6560ft)
Reel
CLB-A10-024B-SHX
700012115
24
OS SM
2000m (6560ft)
Reel
CLB-A10-036B-SHX
700012123
36
OS SM
2000m (6560ft)
Reel
Fibres
OptiSPEED
Indoor/Outdoor
LSZH Fibre Optic Cable (contd)
Cable Contents Page
QUALIFICATION TEST DATA: Te s t N a m e
Results
EIA/TIA
EN 184 000
ISO/IEC
Tensile Load Rating
2,668N (600lbs)
455-33
Method 501
60794-1-E1
Impact 25 Cycle
6.0kg (13lbs)
455-25
Method 505
60794-1-E4
Compression Load
6,672N (1,500lbs)
455-41
Method 504
60794-1-E3
Flexure 25 Cycle Mandrel
44mm (1.75 in)
455-104
Method 509
60794-1-E6
Twist 360 Degree
1 meter (39.4in)
455-85
Method 508
60794-1-E7
Hot Bend 65ºC Mandrel
12.7cm (5in)
455-37
Method 513
60794-1-E11-p1
Cold Bend -30ºC Mandrel
12.7cm (5in)
455-37
Method 513
60794-1-E11-p1
Temperature Cycle
-40 to 85ºC
N/A
Method 601
60794-1-F1
Freezing -1ºC
24 hours
455-98
Method 606
60794-1-F3
Water Penetration -1 Metre Water Head and 1 Metre Cable
24 hours
455-82
Method 605
60794-1-F3
fibre CABLES 49
Fibre
OptiSPEED
Indoor/Outdoor
LSZH Fibre Optic Cable
Cable Contents Page
The Avaya Indoor/Outdoor LSZH Fibre Optic Cable is a Low Smoke Zero Halogen (LSZH) cable that provides Listed
excellent flame retardance and eliminates the need for splicing between indoor and outdoor cables. Direct outdoor-to-indoor transitions may be completed with this single cable and without a splice. The cable enables your outside plant duct, lashed aerial or direct buried applications to flow seamlessly into the building to satisfy riser applications. The elimination of splicing produces significant labour, material and time savings, and provides better system
Figure 25
performance by avoiding additional attenuation loss. The
Indoor/Outdoor
Indoor/Outdoor Cable also offers easier cable handling,
Fibre Optic Cable
core access and installation. Avaya utilises the highly reliable, field-proven loose buffer tube design as the core of its cable. Optical fibres are placed within gel-filled buffer tubes that protect the fibres from crushing, impact, tensile and environmental forces while providing easy mid-span entry and fibre identification. The cable employs Avaya’s superior
Indoor/Outdoor
performance with the use of super absorbent polymers
FO Cable Cross Section
instead of flooding compounds. The DryBlock design directly improves cable entry and handling. The Indoor/Outdoor Cable passes the following tests: - IEC 754 part 3, Acidity/corrosivity based on pH and conductivity measurements - IEC 332 part 3, Flammability and Fire retardant - NES 713, Toxicity index
fibre CABLES
- IEC 1034, Smoke Emissions The Indoor/Outdoor Cable meet or exceeds all LAN/ Cabling standards established or proposed for campus Cables such as ANSI-FDDI, EIA/TIA 568A, ISO/IEC IS11801 and CENELEC EN50173.
Physical Specifications Cable Minimum Bending Radius: Under Load: 20x cable diam. Under no Load: 10x cable diam.
50
Figure 26
DryBlock core design, which achieves water blocking
Max. Pulling Tension: 275kg Operating Temperature Range: -40 to 7ºC
Fibre
OptiSPEED
Indoor/Outdoor
LSZH Fibre Optic Cable (contd) Product
Comcode
Fibre Count
We i g h t (kg/km)
O.D. (mm)
AT-34M12O6-004
999900019
4
133
11.5
AT-34M12O6-006
999900020
6
133
11.5
AT-34M12O6-008
999900021
8
133
AT-34M12O6-012
999900022
12
133
AT-34M12O6-016
999900023
16
AT-34M12O6-018
999900024
AT-34M12O6-024
999900025
AT-34M12O6-030 AT-34M12O6-036
Fibre Ty p e
Cable Contents Page
Max. Length
Packaging
SM
5800m (19000ft)
Reel
SM
5800m (19000ft)
Reel
11.5
SM
5800m (19000ft)
Reel
11.5
SM
5800m (19000ft)
Reel
133
11.5
SM
5800m (19000ft)
Reel
18
133
11.5
SM
5800m (19000ft)
Reel
24
133
11.5
SM
5800m (19000ft)
Reel
999900026
30
133
11.5
SM
5800m (19000ft)
Reel
999900027
36
151
12.3
SM
5400m (17700ft)
Reel
AT-34M12O6-048
999900028
48
186
13.8
SM
4800m (15700ft)
Reel
AT-34M12O6-060
999900029
60
186
13.8
SM
4800m (15700ft)
Reel
AT-34M12O6-072
999900030
72
186
13.8
SM
4800m (15700ft)
Reel
AT-RU912O6-004
999900001
4
133
11.5
MM
5800m (19000ft)
Reel
AT-RU912O6-006
999900002
6
133
11.5
MM
5800m (19000ft)
Reel
AT-RU912O6-008
999900003
8
133
11.5
MM
5800m (19000ft)
Reel
AT-RU912O6-012
999900004
12
133
11.5
MM
5800m (19000ft)
Reel
AT-RU912O6-016
999900005
16
133
11.5
MM
5800m (19000ft)
Reel
AT-RU912O6-018
999900006
18
133
11.5
MM
5800m (19000ft)
Reel
AT-RU912O6-024
999900007
24
133
11.5
MM
5800m (19000ft)
Reel
AT-RU912O6-030
999900008
30
133
11.5
MM
5800m (19000ft)
Reel
AT-RU912O6-036
999900009
36
151
12.3
MM
5400m (17700ft)
Reel
AT-RU912O6-048
999900010
48
186
13.8
MM
4800m (15700ft)
Reel
AT-RU912O6-060
999900011
60
186
13.8
MM
4800m (15700ft)
Reel
AT-RU912O6-072
999900012
72
186
13.8
MM
4800m (15700ft)
Reel
fibre CABLES 51
Fibre
OptiSPEED
Armoured is an innovative, dual-purpose cable that allows you to make a direct outdoor-to-indoor transition with a
Indoor/Outdoor
LSZH, Riser-Rated, Indoor/Outdoor Loose Tube Fibre Optic Cable
Cable Contents Page
single cable without a splice. This durable, dry water-blocked cable offers the mechanical and environmental performance needed for outside plant applications plus the low smoke zero halogen (LSZH) and flame resistance features required for indoor riser applications. Moreover, Armoured’s superior crush and rodent resistance make it ideal for harsh outside plant and direct buried applications. A corrugated steel armour is applied for superior crush and rodent resistance. And an outer flame and UV-resistant jacket completes the construction of a cable that’s durable enough for the toughest outside applications, yet flexible and flame retardant enough for indoor riser applications. Full details of these designs are available from your local
fibre CABLES
Listed
52
Avaya Representative.
Figure 27 Indoor/Outdoor FO Cable Cross Section
Cords Chapter
2
53
Cords Contents
Copper GigaSPEED
Fibre
®
LazrSPEED™
D8CM
55
LC
79
D8CH
60
ST
80
117CM
61
SC
81
119P8CM, 120CM
62
Hybrid
82
VisiPatch™
64
119P8UP
67
110GS
68
D8MC6
69
D8CN
71
Power Sum
OptiSPEED™ LC
84
ST
87
SC
89
Hybrid
92
Miscellaneous
110P2CAT5F
73
Pigtails LC, SC, ST
97
110P2CAT5L
74
Patch Cords Colour Codes
98
Pigtails Colour Codes
98
Miscellaneous
54
Click Here Main Menu
25-Pair Cords
75
D8EX Cross-over Cords
78
CORDS
Copper
D8CM Modular Cord
GigaSPEED®
Modular Patch Cords
Cords Contents Page
The D8CM SYSTIMAX GigaSPEED Cords are designed to ®
assure high performance over longer distances. The D8CM Cords are available in a wide variety of colours and lengths. They are ideal for high activity environments that require reliable data transmissions. Through an exclusive design and manufacturing process, impedance characteristics for GigaSPEED cords are closely matched to impedance levels for GigaSPEED cables, minimising signal reflection and significantly increasing performance margins.
Figure 28 D8CM Modular Patch Cords
Attenuation improvement exceeding the cordage requirement of EIA/TIA 568A and ISO/IEC 11801 maintains performance over longer distances than standard cords. Features – Lower profile than our D8GS – High Performance – Low Variability – Anti-Snag Feature – Full Family of Colours, Lengths, and Configurations – Stranded Conductors – Plenum & Non-Plenum – Supports both Power Sum and GigaSPEED offers – Backward compatible with Cat 5, and Cat 5e systems
Comcode
Length
Packaging
Colour
D8CM-50
108566530
15.2m (50ft)
ea
Grey
D8CM-100
108566548
30.5m (100ft)
ea
Grey
D8CM-200
108566555
60.9m (200ft)
ea
Grey
D8CM-300
108566563
91.4m (300ft)
ea
Grey
D8CM-6M
108566571
6m (19.7ft)
ea
Grey
D8CM-30M
108566589
30m (98.4ft)
ea
Grey
D8CM-6"
108566399
15m (6in)
ea
Grey
D8CM-1
108566407
0.3m (1ft)
ea
Grey
D8CM-2
108566415
0.6m (2ft)
ea
Grey
D8CM-3
108566423
0.9m (3ft)
ea
Grey
D8CM-4
108566431
1.2m (4ft)
ea
Grey
D8CM-5
108566449
1.5m (5ft)
ea
Grey
D8CM-6
108566456
1.8m (6ft)
ea
Grey
D8CM-7
108544529
2.1m (7ft)
ea
Grey
D8CM-8
108566464
2.4m (8ft)
ea
Grey
D8CM-9
108566472
2.7m (9ft)
ea
Grey
CORDS
Product
55
CORDS
Copper
D8CM
GigaSPEED
CORDS
Modular Patch Cords (contd)
56
Product
Comcode
Length
Packaging
Colour
D8CM-10
108566480
3m (10ft)
ea
Grey
D8CM-14
108566498
4.3m (14ft)
ea
Grey
D8CM-15
108566506
4.6m (15ft)
ea
Grey
D8CM-19
108566514
5.8m (19ft)
ea
Grey
D8CM-25
108566522
7.6m (25ft)
ea
Grey
D8CM-1
108566597
0.3m (1ft)
ea
Blue
D8CM-2
108566605
0.6m (2ft)
ea
Blue
D8CM-3
108566613
0.9m (3ft)
ea
Blue
D8CM-4
108566621
1.2m (4ft)
ea
Blue
D8CM-5
108566639
1.5m (5ft)
ea
Blue
D8CM-6
108566647
1.8m (6ft)
ea
Blue
D8CM-7
108566654
2.1m (7ft)
ea
Blue
D8CM-8
108566662
2.4m (8ft)
ea
Blue
D8CM-9
108566670
2.7m (9ft)
ea
Blue
D8CM-10
108566688
3m (10ft)
ea
Blue
D8CM-14
108566696
4.3m (14ft)
ea
Blue
D8CM-15
108669961
4.6m (15ft)
ea
Blue
D8CM-19
108566704
5.8m (19ft)
ea
Blue
D8CM-25
108566712
7.6m (25ft)
ea
Blue
D8CM-50
108566720
15.2m (50ft)
ea
Blue
D8CM-1
108566738
0.3m (1ft)
ea
Ivory
D8CM-2
108566746
0.6m (2ft)
ea
Ivory
D8CM-3
108566753
0.9m (3ft)
ea
Ivory
D8CM-4
108566761
1.2m (4ft)
ea
Ivory
D8CM-5
108566779
1.5m (5ft)
ea
Ivory
D8CM-6
108566787
1.8m (6ft)
ea
Ivory
D8CM-7
108566795
2.1m (7ft)
ea
Ivory
D8CM-8
108566803
2.4m (8ft)
ea
Ivory
D8CM-9
108566811
2.7m (9ft)
ea
Ivory
D8CM-10
108566829
3m (10ft)
ea
Ivory
D8CM-14
108566837
4.3m (14ft)
ea
Ivory
D8CM-15
108669979
4.6m (15ft)
ea
Ivory
D8CM-19
108566845
5.8m (19ft)
ea
Ivory
D8CM-25
108566852
7.6m (25ft)
ea
Ivory
D8CM-50
108566860
15.2m (50ft)
ea
Ivory
D8CM-1
108566878
0.3m (1ft)
ea
Orange
D8CM-2
108566886
0.6m (2ft)
ea
Orange
D8CM-3
108566894
0.9m (3ft)
ea
Orange
D8CM-4
108566902
1.2m (4ft)
ea
Orange
D8CM-5
108566910
1.5m (5ft)
ea
Orange
Cords Contents Page
CORDS
Copper
D8CM
GigaSPEED
Modular Patch Cords (contd)
Comcode
Length
Packaging
Colour
D8CM-6
108566928
1.8m (6ft)
ea
Orange
D8CM-7
108566936
2.1m (7ft)
ea
Orange
D8CM-8
108566944
2.4m (8ft)
ea
Orange
D8CM-9
108566951
2.7m (9ft)
ea
Orange
D8CM-10
108566969
3m (10ft)
ea
Orange
D8CM-14
108566977
4.3m (14ft)
ea
Orange
D8CM-15
108669987
4.6m (15ft)
ea
Orange
D8CM-19
108566985
5.8m (19ft)
ea
Orange
D8CM-25
108566993
7.6m (25ft)
ea
Orange
D8CM-50
108567009
15.2m (50ft)
ea
Orange
D8CM-1
108567017
0.3m (1ft)
ea
Red
D8CM-2
108567025
0.6m (2ft)
ea
Red
D8CM-3
108567033
0.9m (3ft)
ea
Red
D8CM-4
108567041
1.2m (4ft)
ea
Red
D8CM-5
108567058
1.5m (5ft)
ea
Red
D8CM-6
108567066
1.8m (6ft)
ea
Red
D8CM-7
108567074
2.1m (7ft)
ea
Red
D8CM-8
108567082
2.4m (8ft)
ea
Red
D8CM-9
108567090
2.7m (9ft)
ea
Red
D8CM-10
108567108
3m (10ft)
ea
Red
D8CM-14
108567116
4.3m (14ft)
ea
Red
D8CM-15
108669995
4.6m (15ft)
ea
Red
D8CM-19
108567132
5.8m (19ft)
ea
Red
D8CM-25
108567140
7.6m (25ft)
ea
Red
D8CM-50
108567157
15.2m (50ft)
ea
Red
D8CM-1
108570680
0.3m (1ft)
ea
Green
D8CM-2
108570698
0.6m (2ft)
ea
Green
D8CM-3
108570706
0.9m (3ft)
ea
Green
D8CM-4
108570714
1.2m (4ft)
ea
Green
D8CM-5
108570722
1.5m (5ft)
ea
Green
D8CM-6
108570730
1.8m (6ft)
ea
Green
D8CM-7
108570748
2.1m (7ft)
ea
Green
D8CM-8
108570755
2.4m (8ft)
ea
Green
D8CM-9
108570763
2.7m (9ft)
ea
Green
D8CM-10
108570771
3m (10ft)
ea
Green
D8CM-14
108570789
4.3m (14ft)
ea
Green
D8CM-15
108670001
4.6m (15ft)
ea
Green
D8CM-19
108570797
5.8m (19ft)
ea
Green
D8CM-25
108570805
7.6m (25ft)
ea
Green
D8CM-50
108570813
15.2m (50ft)
ea
Green
CORDS
Product
Cords Contents Page
57
CORDS
Copper
D8CM
GigaSPEED
CORDS
Modular Patch Cords (contd)
58
Product
Comcode
Length
Packaging
Colour
D8CM-1
108571266
0.3m (1ft)
ea
Sable
D8CM-2
108571274
0.6m (2ft)
ea
Sable
D8CM-3
108571282
0.9m (3ft)
ea
Sable
D8CM-4
108571290
1.2m (4ft)
ea
Sable
D8CM-5
108571308
1.5m (5ft)
ea
Sable
D8CM-6
108571324
1.8m (6ft)
ea
Sable
D8CM-7
108571332
2.1m (7ft)
ea
Sable
D8CM-8
108571340
2.4m (8ft)
ea
Sable
D8CM-9
108571357
2.7m (9ft)
ea
Sable
D8CM-10
108571365
3m (10ft)
ea
Sable
D8CM-14
108571373
4.3m (14ft)
ea
Sable
D8CM-15
108670019
4.6m (15ft)
ea
Sable
D8CM-19
108571381
5.8m (19ft)
ea
Sable
D8CM-25
108571399
7.6m (25ft)
ea
Sable
D8CM-50
108571407
15.2m (50ft)
ea
Sable
D8CM-1
108571415
0.3m (1ft)
ea
Lilac
D8CM-2
108571423
0.6m (2ft)
ea
Lilac
D8CM-3
108571431
0.9m (3ft)
ea
Lilac
D8CM-4
108571449
1.2m (4ft)
ea
Lilac
D8CM-5
108571456
1.5m (5ft)
ea
Lilac
D8CM-6
108571464
1.8m (6ft)
ea
Lilac
D8CM-7
108571472
2.1m (7ft)
ea
Lilac
D8CM-8
108571480
2.4m (8ft)
ea
Lilac
D8CM-9
108571498
2.7m (9ft)
ea
Lilac
D8CM-10
108571506
3m (10ft)
ea
Lilac
D8CM-14
108571514
4.3m (14ft)
ea
Lilac
D8CM-15
108670035
4.6m (15ft)
ea
Lilac
D8CM-19
108571522
5.8m (19ft)
ea
Lilac
D8CM-25
108571530
7.6m (25ft)
ea
Lilac
D8CM-50
108571548
15.2m (50ft)
ea
Lilac
D8CM-1
108571555
0.3m (1ft)
ea
Yellow
D8CM-2
108571563
0.6m (2ft)
ea
Yellow
D8CM-3
108571571
0.9m (3ft)
ea
Yellow
D8CM-4
108571589
1.2m (4ft)
ea
Yellow
D8CM-5
108571597
1.5m (5ft)
ea
Yellow
D8CM-6
108571605
1.8m (6ft)
ea
Yellow
D8CM-7
108571613
2.1m (7ft)
ea
Yellow
D8CM-8
108571621
2.4m (8ft)
ea
Yellow
D8CM-9
108571639
2.7m (9ft)
ea
Yellow
D8CM-10
108571647
3m (10ft)
ea
Yellow
Cords Contents Page
CORDS
Copper
D8CM
GigaSPEED
Modular Patch Cords (contd)
Product
Comcode
Length
Packaging
Colour
D8CM-14
108571654
4.3m (14ft)
ea
Yellow
D8CM-15
108670043
4.6m (15ft)
ea
Yellow
D8CM-19
108571662
5.8m (19ft)
ea
Yellow
D8CM-25
108571670
7.6m (25ft)
ea
Yellow
D8CM-50
108571688
15.2m (50ft)
ea
Yellow
Cords Contents Page
CORDS 59
CORDS
Copper
D8CH - Solid Core Double ended LSZH Cords
GigaSPEED
4-Pair Modular Cords
The D8CH is a 3071 Low Smoke Zero Halogen solid cable which is terminated with the new CM 8-pin connectorised plugs. The D8CH modular cords support Power Sum and GigaSPEED solutions; it is backward compatible with CAT5 and CAT5e systems, offers high performance and low variability. The D8CH complies with IEC 754- part 2, 2.H band on PH and conductivity measurements. With IEC 7034 part 2, Smoke Emissions, IEC 332 part 3, Flammability and Fire Retardant and NES 713, Toxicity Index.
Product
Comcode
Length
Termination
Packaging
Colour
D8CH-DEWH-1
108834565
0.3m (1ft)
Double-ended
ea
White
D8CH-DEWH-2
108834573
0.6m (2ft)
Double-ended
ea
White
D8CH-DEWH-3
108834581
0.9m (3ft)
Double-ended
ea
White
D8CH-DEWH-4
108834599
1.2m (4ft)
Double-ended
ea
White
D8CH-DEWH-5
108834607
1.5m (5ft)
Double-ended
ea
White
D8CH-DEWH-6
108834615
1.8m (6ft)
Double-ended
ea
White
D8CH-DEWH-7
108834623
2.1m (7ft)
Double-ended
ea
White
D8CH-DEWH-8
108834631
2.4m (8ft)
Double-ended
ea
White
D8CH-DEWH-9
108834649
2.7m (9ft)
Double-ended
ea
White
D8CH-DEWH-10
108834656
3m (10ft)
Double-ended
ea
White
D8CH-DEWH-14
108834664
4.3m (14ft)
Double-ended
ea
White
D8CH-DEWH-15
108834672
4.6m (15ft)
Double-ended
ea
White
D8CH-DEWH-19
108834680
5.8m (19ft)
Double-ended
ea
White
D8CH-DEWH-25
108834698
7.6m (25ft)
Double-ended
ea
White
D8CH-DEWH-6M
108834706
6m (19.7ft)
Double-ended
ea
White
30m (98.4ft)
Double-ended
ea
White
CORDS
D8CH-DEWH-30M 108834714
60
Cords Contents Page
CORDS
Copper
117CM Hybrid Cord
GigaSPEED
RJ45 - Unterminated
Cords Contents Page
The 117CM is a single ended CM plug to unterminated over stranded 1074D cordage. This cord has a higher performance with lower variability. It supports both Power Sum and GigaSPEED Solutions and is backward compatible with existing CAT5 and CAT5e systems.
Product
Comcode
Length
Package
Colour
117CM-15
108669474
4.6m (15ft)
ea
Grey
117CM-30
108669482
9.1m (30ft)
ea
Grey
CORDS 61
CORDS
Copper
119P8CM & 120CM
GigaSPEED
Hybrid RJ45 - 110
Cords Contents Page
The 119P8CM will consist of the CM plug terminated over stranded 1074D cordage to the 110 connector. The 120CM Cords can be used to patch RJ45 ports of high speed equipment devices to the 110 connector system. All cords have a higher performance with lower variability. They support both Power Sum and GigaSPEED Solutions and are backward compatible with existing CAT5 and CAT5e systems. Figure 29
CORDS
119P Hybrid Cord
62
Product
Comcode
Length
Packaging
Colour
119P8CM-2B
108671769
0.6m (2ft)
ea
Grey
119P8 CM-3B
108671777
0.9m (3ft)
ea
Grey
119P8 CM-4B
108671785
1.2m (4ft)
ea
Grey
119P8 CM-5B
108671793
1.5m (5ft)
ea
Grey
119P8 CM-6B
108671801
1.8m (6ft)
ea
Grey
119P8 CM-7B
108671827
2.1m (7ft)
ea
Grey
119P8 CM-8B
108671835
2.4m (8ft)
ea
Grey
119P8 CM-9B
108671843
2.7m (9ft)
ea
Grey
119P8 CM-12B
108671850
3.7m (12ft)
ea
Grey
119P8 CM-15B
108671868
4.6m (15ft)
ea
Grey
119P8 CM-18B
108671876
5.5m (18ft)
ea
Grey
119P8CMBL-3B
108689514
0.9m (3ft)
ea
Blue
119P8CMBL-5B
108689548
1.5m (5ft)
ea
Blue
119P8CMBL-7B
108689563
2.1m (7ft)
ea
Blue
119P8CMBL-9B
108689589
2.7m (9ft)
ea
Blue
119P8CMBL-12B
108689597
3.7m (12ft)
ea
Blue
119P8CMGN-3B
108694100
0.9m (3ft)
ea
Green
119P8CMGN-5B
108694126
1.5m (5ft)
ea
Green
119P8CMGN-7B
108694142
2.1m (7ft)
ea
Green
119P8CMGN-9B
108694167
2.7m (9ft)
ea
Green
119P8CMGN-12B
108694175
3.7m (12ft)
ea
Green
119P8CMIV-3B
108707225
0.9m (3ft)
ea
Ivory
119P8CMIV-5B
108707241
1.5m (5ft)
ea
Ivory
119P8CMIV-7B
108707266
2.1m (7ft)
ea
Ivory
119P8CMIV-9B
108707282
2.7m (9ft)
ea
Ivory
119P8CMIV-12B
108707290
3.7m (12ft)
ea
Ivory
119P8CMLL-3B
108694217
0.9m (3ft)
ea
Lilac
119P8CMLL-5B
108694233
1.5m (5ft)
ea
Lilac
119P8CMLL-7B
108694258
2.1m (7ft)
ea
Lilac
119P8CMLL-9B
108694274
2.7m (9ft)
ea
Lilac
CORDS
Copper
119P8CM & 120CM
GigaSPEED
Hybrid RJ45 - 110 (contd)
Product
Comcode
Length
Packaging
Colour
119P8CMLL-12B
108694282
3.7m (12ft)
ea
Lilac
119P8CMOR-3B
108707332
0.9m (3ft)
ea
Orange
119P8CMOR-5B
108707352
1.5m (5ft)
ea
Orange
119P8CMOR-7B
108707373
2.1m (7ft)
ea
Orange
119P8CMOR-9B
108707399
2.7m (9ft)
ea
Orange
119P8CMOR-12B
108707407
3.7m (12ft)
ea
Orange
119P8CMRD-3B
108708504
0.9m (3ft)
ea
Red
119P8CMRD-5B
108708520
1.5m (5ft)
ea
Red
119P8CMRD-7B
108708546
2.1m (7ft)
ea
Red
119P8CMRD-9B
108708561
2.7m (9ft)
ea
Red
119P8CMRD-12B
108708579
3.7m (12ft)
ea
Red
119P8CMSA-3B
108708611
0.9m (3ft)
ea
Sable
119P8CMSA-5B
108708637
1.5m (5ft)
ea
Sable
119P8CMSA-7B
108708652
2.1m (7ft)
ea
Sable
119P8CMSA-9B
108708678
2.7m (9ft)
ea
Sable
119P8CMSA-12B
108708686
3.7m (12ft)
ea
Sable
119P8CMYW-3B
108708728
0.9m (3ft)
ea
Yellow
119P8CMYW-5B
108708744
1.5m (5ft)
ea
Yellow
119P8CMYW-7B
108708769
2.1m (7ft)
ea
Yellow
119P8CMYW-9B
108708785
2.7m (9ft)
ea
Yellow
119P8CMYW-12B
108708793
3.7m (12ft)
ea
Yellow
120P4CAT5F-12B
107774549
3.6m (12ft)
ea
Grey
120P4CAT5F-20B
107774556
6m (20ft)
ea
Grey
Cords Contents Page
CORDS 63
CORDS
Copper
VisiPatch™ 110 1- Pair Patch Cords
GigaSPEED
110 GS Patch Cords
The 110 1-Pair Patch Cord utilises a patented connector design that allows the cordage to be neatly routed back toward the VisiPatch panel rather than to project forward. The connector snaps on with an audible
CORDS
click and features an anti-snag device, which allows the cord to be easily removed from the panel.
64
Product
Comcode
Length
Packaging
110P2UP-GS-2
108535527
0.6m (2ft)
ea
110P2UP-GS-3
108535576
0.9m (3ft)
ea
110P2UP-GS-4
108535584
1.2m (4ft)
ea
110P2UP-GS-5
108535592
1.5m (5ft)
ea
110P2UP-GS-6
108535600
1.8m (6ft)
ea
110P2UP-GS-7
108535618
2.1m (7ft)
ea
110P2UP-GS-8
108535626
2.4m (8ft)
ea
110P2UP-GS-9
108535634
2.7m (9ft)
ea
110P2UP-GS-12
108535642
3.7m (12ft)
ea
110P2UP-GS-15
108535659
4.6m (15ft)
ea
110P2UP-GS-18
108535667
5.5m (18ft)
ea
Cords Contents Page
CORDS
Copper
VisiPatch 110 2- Pair Patch Cords
GigaSPEED
110 GS Patch Cords
Cords Contents Page
The 110 2-Pair Patch Cord utilises a patented connector design that allows the cordage to be neatly routed back toward the VisiPatch panel rather than to project forward. The connector snaps on with an audible click and features an anti-snag device, which allows the cord to be easily removed from the panel.
Figure 30 110 2-Pair Patch Cord
Product
Comcode
Length
Packaging
110P4UP-GS-2
108535675
0.6m (2ft)
ea
110P4UP-GS-3
108535683
0.9m (3ft)
ea
110P4UP-GS-4
108535691
1.2m (4ft)
ea
110P4UP-GS-5
108535709
1.5m (5ft)
ea
110P4UP-GS-6
108535717
1.8m (6ft)
ea
110P4UP-GS-7
108535725
2.1m (7ft)
ea
110P4UP-GS-8
108535733
2.4m (8ft)
ea
110P4UP-GS-9
108535741
2.7m (9ft)
ea
110P4UP-GS-12
108535758
3.7m (12ft)
ea
110P4UP-GS-15
108535766
4.6m (15ft)
ea
110P4UP-GS-18
108535774
5.5m (18ft)
ea
CORDS 65
CORDS
Copper
VisiPatch 110 4-Pair Patch Cord
GigaSPEED
110 GS Patch Cords
Cords Contents Page
The 4-Pair Patch Cord utilises a patented connector design that allows the cordage to be neatly routed back toward the VisiPatch panel rather than to project forward. The connector snaps on with an audible click and features an anti-snag device, which allows the cord to be easily removed from the panel.
Figure 31
CORDS
110 4-Pair Patch Cord
66
Product
Comcode
Length
Pair Size
Packaging
Colour
110P8UP-GS-2
108537101
0.6m (2ft)
4
ea
Slate
110P8UP-GS-3
108537119
0.9m (3ft)
4
ea
Slate
110P8UP-GS-4
108537127
1.2m (4ft)
4
ea
Slate
110P8UP-GS-5
108537135
1.5m (5ft)
4
ea
Slate
110P8UP-GS-6
108537143
1.8m (6ft)
4
ea
Slate
110P8UP-GS-7
108537150
2.1m (7ft)
4
ea
Slate
110P8UP-GS-8
108537168
2.4m (8ft)
4
ea
Slate
110P8UP-GS-9
108537176
2.7m (9ft)
4
ea
Slate
110P8UP-GS-12
108537184
3.6m (12ft)
4
ea
Slate
110P8UP-GS-15
108537192
4.5m (15ft)
4
ea
Slate
110P8UP-GS-18
108537200
5.4m (18ft)
4
ea
Slate
CORDS
Copper
119P8UP
GigaSPEED
VisiPatch Cords
Cords Contents Page
The 119 VisiPatch Cords utilise a patented 110 connector design terminated to a GigaSPEED RJ45 connector. This allows the cordage to be neatly routed back towards the VisiPatch Panel. The initial range on offer consists of 0.9m (3ft) to 4.6m (15ft), individually packed, 4-pair cords. The 119 VisiPatch Cords utilise a patented 110 connector design terminated in a GigaSPEED D8CM plug. This allows the cordage to be neatly routed back towards the VisiPatch Panel. The initial range on offer consists of 0.9m (3ft) to 4.6m (15ft), individually packed, 4-pair cords.
Product
Comcode
Length
Packaging
Colour
119P8UP-3
108661091
0.9m (3ft)
ea
Grey
119P8UP-5
108661133
1.5m (5ft)
ea
Grey
119P8UP-7
108661174
2.1m (7ft)
ea
Grey
119P8UP-9
108661224
2.7m (9ft)
ea
Grey
119P8UP-12
108661505
3.7m (12ft)
ea
Grey
119P8UP-15
108661513
4.6m (15ft)
ea
Grey
CORDS 67
CORDS
Copper
110GS Patch Cords
GigaSPEED
110 Patch Cords Designed to ensure high performance over longer distances, the SYSTIMAX GigaSPEED family of cords includes 110GS Patch Cords. Through an exclusive design and manufacturing process, impedance characteristics for GigaSPEED cords are closely matched to impedance levels for GigaSPEED cables, minimising signal reflection and significantly increasing performance margins. Attenuation improvement exceeding the cordage requirement of EIA/TIA 568A and ISO/IEC 11801 maintains performance over longer distances than standard cords. The 110GS plugs and modular plugs reduce termination variability, allowing better performance in mated GigaSPEED plug/jack combinations every time. All GigaSPEED cables and components are covered by a 20 year warranty when installed as part of a
CORDS
registered SYSTIMAX GigaSPEED solution.
68
Product
Comcode
Length
Packaging
Colour
110P2GS-3
108288135
0.9m (3ft)
10/Pkg
Grey
110P2GS-5
108288150
1.5m (5ft)
10/Pkg
Grey
110P2GS-7
108288176
2.1m (7ft)
10/Pkg
Grey
110P2GS-9
108288192
2.7m (9ft)
10/Pkg
Grey
110P2GS-15
108288200
4.6m (15ft)
10/Pkg
Grey
110P4GS-3
108288291
0.9m (3ft)
10/Pkg
Grey
110P4GS-5
108288275
1.5m (5ft)
10/Pkg
Grey
110P4GS-7
108288267
2.1m (7ft)
10/Pkg
Grey
110P4GS-9
108288242
2.7m (9ft)
10/Pkg
Grey
110P4GS-15
108288234
4.5m (15ft)
10/Pkg
Grey
110P8GS-3
108062050
0.9m (3ft)
10/Pkg
Grey
110P8GS-5
108062068
1.5m (5ft)
10/Pkg
Grey
110P8GS-7
108062076
2.1m (7ft)
10/Pkg
Grey
110P8GS-9
108062084
2.7m (9ft)
10/Pkg
Grey
110P8GS-15
108062092
4.5m (15ft)
10/Pkg
Grey
Cords Contents Page
CORDS
Copper
D8MC6
GigaSPEED
Adapter Cords
Cords Contents Page
The D8MC6 GigaSPEED Adapter Cord provides a flexible approach to Zone Wiring and Open Office Architecture solutions. The D8MC6 is a solid conductor adapter cord to be used from consolidation point (or zone wiring box) to the faceplate at the end-user’s desk. It will replace the D8MGS adapter cord. It is terminated with a GigaSPEED D8CM modular plug on one end and a pre-connectorised MGS300 outlet on the other end, using 1075 Solid Cordage. The D8MC6 Adapter Cord provides ease of reconfiguration and increased flexibility for moves, adds and changes. These adapter cords provide an alternative to hard-wiring the portion of the installation that runs from the consolidation point to the end-user’s desk. Unlike hard-wiring, the D8MC6 Cords can be reused after the furniture has been moved or reconfigured. The cords are manufactured in black, white and ivory as standard, but can also be ordered in other colours (grey, blue, red, yellow and orange). Please contact your Avaya representative for ordering information. Other lengths are available upon request.
Description
Length (ft)
Module Colour
108867680
D8MC6NBK5BA
5
Black
108867698
D8MC6NBK10BA
10
Black
108867706
D8MC6NBK15BA
15
Black
108867714
D8MC6NBK20BA
20
Black
108867722
D8MC6NBK25BA
25
Black
108867730
D8MC6NBK33BA
33
Black
108867748
D8MC6PBK20BA
20
Black
108867755
D8MC6PBK25BA
25
Black
108867771
D8MC6PBK33BA
33
Black
108867797
D8MC6PBK40BA
40
Black
108867813
D8MC6PBK50BA
50
Black
108867862
D8MC6NIV5BA
5
Ivory
108867888
D8MC6NIV10BA
10
Ivory
108867904
D8MC6NIV15BA
15
Ivory
108867912
D8MC6NIV20BA
20
Ivory
108867920
D8MC6NIV25BA
25
Ivory
108867938
D8MC6NIV33BA
33
Ivory
108867953
D8MC6PIV20BA
20
Ivory
108867961
D8MC6PIV25BA
25
Ivory
108867987
D8MC6PIV33BA
33
Ivory
108867995
D8MC6PIV40BA
40
Ivory
108868001
D8MC6PIV50BA
50
Ivory
CORDS
Comcode
69
CORDS
Copper
D8MC6
GigaSPEED
CORDS
Adapter Cords (contd)
70
Comcode
Description
Length (ft)
Module Colour
108868019
D8MC6NWH5BA
5
White
108868027
D8MC6NWH10BA
10
White
108868035
D8MC6NWH15BA
15
White
108868043
D8MC6NWH20BA
20
White
108868052
D8MC6NWH25BA
25
White
108868068
D8MC6NWH33BA
33
White
108868076
D8MC6PWH20BA
20
White
108868084
D8MC6PWH25BA
25
White
108868092
D8MC6PWH33BA
33
White
108868100
D8MC6PWH40BA
40
White
108868118
D8MC6PWH50BA
50
White
Cords Contents Page
CORDS
Copper
D8CN Solid Core Single Ended & Double Ended Cords
GigaSPEED
4-Pair Modular Cords
The D8CN Cord is a GigaSPEED cord terminated with an Avaya RJ45 Plug(s). The Avaya patented tight pair twist algorithm used in manufacturing the 1071 cable along with the carefully controlled termination of the specially designed RJ45 plug together produce a solid conductor cord with excellent NEXT performance. These cords are ideal for use in Zone Cabling applications. They are grey in colour, and are available in Single and Double-ended versions. (For alternate lengths please contact your Avaya Representative for ordering information) The D8CN Cord meets or exceeds attenuation and crosstalk Category 5e specifications for patch cords as specified in ISO/IEC 11801, CENELEC EN50173, and EIA/TIA 568A.
Physical Specifications Operating Temperature Range: -10 to 60ºC
Contact Plating: 1.27 µm Gold over 2.540 µm Nickel
Contact Stability: 20m Ω max. change
Plug Retention Force: 110 N
CORDS
Insertion Life: 750 insertions
71
Product
Comcode
Length
Termination
Packaging
D8CN-SEGR-100
108793688
30m (100ft)
Single-ended
1/Pkg
D8CN-DEGR-50
108793753
15.2m (50ft)
Double-ended
1/Pkg
Cords Contents Page
CORDS
Copper
110P2CAT5F
Power Sum
110 Stranded Wire
Cords Contents Page
The Power Sum 110 Patch Cords using 1074 Cordage and Listed
110 Patch Cord Plugs are available in factory-connectorised 1, 2, 3, and 4-pair sizes. These cords are grey in colour while a select number of 4-pair cords are also manufactured in blue, orange, green, lilac, ivory, red and sable (please contact your Avaya representative for ordering information). Other lengths are available upon request. Figure 32
The factory-connectorised Power Sum 110 Patch Cord
110P2CAT5,
incorporates Avaya patented “cross-over lead” design,
110P4CAT5,
which employs crosstalk cancellation techniques to provide
110P6CAT5 and 110P8CAT5
superior Near-End Crosstalk (NEXT) performance. These
Patch Cords
110 Patch Cords meet or exceed attenuation and NEXT Category 5 and Category 5e specifications for Patch Cords as specified in ISO/IEC 11801, CENELEC EN50173, and EIA/TIA 568A. Further, these Patch Cords are UL verified as Category 5e, and UL listed type CM.
Physical Specifications Operating Temperature Range: -10 to 60ºC Contact Plating: 1.27 µm Gold over 1.905 µm Nickel Contact Stability: 5m Ω max. change Plug Retention Force (Depending on Pair Size): 27 to 110 N Insertion Life: > 200 insertions
Attenuation dB/100m
Power Sum EXT (Ave) dB
1
1.9
73
4
3.9
61
8
5.5
57
10
6.3
56
16
8.0
53
20
8.9
52
25
10.0
51
31.25
11.2
49
62.5
16.1
45
100
20.7
42
CORDS
Frequency MHz
72
CORDS
Copper
110P2CAT5F
Power Sum
CORDS
110 Stranded Wire (contd)
73
Product
Comcode
Pair Size
Length
Packaging
110P2CAT5F-2B
107733206
1
0.6m (2ft)
10/Pkg
110P2CAT5F-3B
107733214
1
0.9m (3ft)
10/Pkg
110P2CAT5F-5B
107733230
1
1.5m (5ft)
10/Pkg
110P2CAT5F-7B
107733255
1
2.1m (7ft)
10/Pkg
110P2CAT5F-8B
107733263
1
2.4m (8ft)
10/Pkg
110P2CAT5F-12B
107733289
1
3.7m (12ft)
10/Pkg
110P2CAT5F-15B
107733297
1
4.6m (15ft)
10/Pkg
110P4CAT5F-2B
107733313
2
0.6m (2ft)
10/Pkg
110P4CAT5F-3B
107733321
2
0.9m (3ft)
10/Pkg
110P4CAT5F-5B
107733347
2
1.5m (5ft)
10/Pkg
110P4CAT5F-7B
107733362
2
2.1m (7ft)
10/Pkg
110P4CAT5F-8B
107733370
2
2.4m (8ft)
10/Pkg
110P4CAT5F-12B
107733396
2
3.7m (12ft)
10/Pkg
110P4CAT5F-15B
107733404
2
4.6m (15ft)
10/Pkg
110P6CAT5F-2B
107733420
3
0.6m (2ft)
10/Pkg
110P6CAT5F-3B
107733438
3
0.9m (3ft)
10/Pkg
110P6CAT5F-5B
107733453
3
1.5m (5ft)
10/Pkg
110P6CAT5F-7B
107733479
3
2.1m (7ft)
10/Pkg
110P6CAT5F-8B
107733487
3
2.4m (8ft)
10/Pkg
110P6CAT5F-12B
107733503
3
3.7m (12ft)
10/Pkg
110P6CAT5F-15B
107733511
3
4.6m (15ft)
10/Pkg
110P8CAT5F-2B
107733537
4
0.6m (2ft)
10/Pkg
110P8CAT5F- 3B
107733545
4
0.9m (3ft)
10/Pkg
110P8CAT5F-5B
107733560
4
1.5m (5ft)
10/Pkg
110P8CAT5F-7B
107733586
4
2.1m (7ft)
10/Pkg
110P8CAT5F- 8B
107733594
4
2.4m (8ft)
10/Pkg
110P8CAT5F-12B
107733610
4
3.7m (12ft)
10/Pkg
110P8CAT5F-15B
107733628
4
4.6m (15ft)
10/Pkg
Cords Contents Page
CORDS
Copper
110P2CAT5L
Power Sum
110 Stranded Wire
Cords Contents Page
The 110P2CAT5L Patch Cords utilise 3074 Low Smoke Zero Halogen (LSZH) cordage and are available in factory connectorised 1, 2, 3, and 4-pair sizes. The colour of the 110P2CAT5L is white. Other lengths are available upon request. The Avaya patented tight pair twist algorithm used in manufacturing the LSZH 3074 cordage along with the carefully controlled termination of the specially designed 110 plug together produce a 110P2CAT5L Patch Cord with excellent Power Sum NEXT performance.
Figure 33 LSZH Stranded Wire
The 110P2CAT5L Patch Cords meet the following IEC requirements: - IEC 754 part 2, Zero Halogen based on pH and Conductivity measurements - IEC 1034 part 2, Smoke Emission - IEC 332 part 1, Flammability and Fire Retardant - NES 713, Toxicity Index The factory-connectorised 110P2CAT5L cords meet or exceed attenuation and crosstalk Category 5e specifications for work area cords as specified in ISO/IEC IS 11801 (1995), CENELEC EN50173 (1995), and EIA/TIA 568A (1995). Also, the 110P2CAT5L cords are UL verified as Category 5, Listed
and UL listed type CM.
Physical Specifications Operating Temperature Range: -10 to 60ºC
Contact Plating: 1.27 µm Gold over 1.905 µm Nickel
Contact Stability: 5m Ω max. change
Plug Retention Force (Depending on Pair Size): 27 to 110 N
Insertion Life: > 200 insertions
Comcode
Pair Size
Length
CORDS
Product
Packaging
110P2CAT5L-3B
107855843
1
0.9m (3ft)
10/Pkg
110P2CAT5L-5B
107855868
1
1.5m (5ft)
10/Pkg
110P2CAT5L-7B
107855892
1
2.1m (7ft)
10/Pkg
110P4CAT5L-3B
107856007
2
0.9m (3ft)
10/Pkg
110P4CAT5L-5B
107856023
2
1.5m (5ft)
10/Pkg
110P4CAT5L-7B
107856049
2
2.1m (7ft)
10/Pkg
110P6CAT5L-3B
107856130
3
0.9m (3ft)
10/Pkg
110P6CAT5L-5B
107856163
3
1.5m (5ft)
10/Pkg
110P6CAT5L-7B
107856197
3
2.1m (7ft)
10/Pkg
110P8CAT5L-3B
107856288
4
0.9m (3ft)
10/Pkg
110P8CAT5L-5B
107856346
4
1.5m (5ft)
10/Pkg
110P8CAT5L-7B
107856387
4
2.1m (7ft)
10/Pkg
74
CORDS
Copper
25-Pair Cords
Miscellaneous
Power Sum Multi-Pair
Cords Contents Page
The Avaya 525 Connectorised 25-Pair Power Sum Cords consist of the 1061 Power Sum 25-pair cable terminated at each end with an Avaya 525 Category 5e telco-type connector. The 1061C 25-pair cable is a high speed, 100 ohm high performance cable with excellent Power Sum NEXT levels which ensures excellent high speed transmission. (See Specifications for the Avaya 1061 25-Pair Cable). Specially designed by Avaya Labs, the 525 Power Sum 25-Pair Connector is fully backwards compatible with Figure 34
the standard telco connector, in both pinout and physical
525 Connectorised Cord
connectability. This compatibility provides a user-friendly migration path from today’s technologies - including the widely deployed 10Base-T to sophisticated, high performance ATM applications. The 525 Connector exceeds Category 5 Power Sum Near End Crosstalk (PSNEXT) requirements by an average factor of 6 dB (the noise level is less than half the maximum allowed). The 525 Connectorised Category 5 Cords currently available have male plugs on each end, and may be ordered with a Listed
90º, 110º Left hand, 110º Right hand, or 180º Angle Options.
Physical Specifications Gauge: 0.511mm (24 AWG)
Outside Diameter: 13.0mm
Insulation Thickness: 0.22mm
Jacket Thickness: 0.68mm
Operating Temperature Range: -10 to 60ºC
Insertion Life: >200 insertions
Min. Contact Force: 100g Contact Plating in Mating Region: 0.76 µm in Gold over 1.27 µm Nickel Meets FCC Part 68 Subpart F mating area dimensional requirements
Attenuation (dB)
PSNEXT (dB)
Return Loss
1
0.01
86
58
4
0.01
74
55
8
0.01
68
52
10
0.02
66
51
16
0.02
62
48
20
0.02
60
46
25
0.02
58
45
31.25
0.02
56
43
62.5
0.03
50
38
100
0.06
46
34
CORDS
Frequency (MHz)
75
CORDS
Copper
25-Pair Cords
Miscellaneous
Power Sum Multi-Pair (contd) Product
Comcode
Cords Contents Page
Length
Packaging
1/Pkg
In-Line (180) to In-Line (180) CC525CC-005A
108156001
1.5m (5ft)
CC525CC-010A
108156027
3m (10ft)
1/Pkg
CC525CC-015A
108199761
4.6m (15ft)
1/Pkg
CC525CC-025A
108156068
7.6m (25ft)
1/Pkg
CC525CC-050A
108036740
15.2m (50ft)
1/Pkg
1/Pkg
In-Line (180) to Standard (90) CC525CP-005A
108262924
1.5m (5ft)
CC525CP-010A
108262932
3m (10ft)
1/Pkg
CC525CP-015A
108263047
4.6m (15ft)
1/Pkg
CC525CP-025A
108263054
7.6m (25ft)
1/Pkg
CC525CP-050A
108036757
15.2m (50ft)
1/Pkg
Left Angled (110) to Right Angled (110) CC525AR-005A
108234584
1.5m (5ft)
1/Pkg
CC525AR-010A
108234592
3m (10ft)
1/Pkg
CC525AR-015A
108234600
4.6m (15ft)
1/Pkg
CC525AR-025A
108234618
7.5m (25ft)
1/Pkg
CC525AR-050A
108234626
15.2m (50ft)
1/Pkg
Right Angled (110) to In-Line (180) CC525RC-005A
108189291
1.5m (5ft)
1/Pkg
CC525RC-010A
108189317
3m (10ft)
1/Pkg
CC525RC-015A
108199753
4.6m (15ft)
1/Pkg
CC525RC-025A
108189333
7.6m (25ft)
1/Pkg
CC525RC-050A
108189341
15.2m (50ft)
1/Pkg
1/Pkg
CORDS
Left Angled (110) to In-Line (180) CC525AC-005A
108189515
1.5m (5ft)
CC525AC-010A
108199720
3m (10ft)
1/Pkg
CC525AC-015A
108199738
4.6m (15ft)
1/Pkg
CC525AC-025A
108199746
7.6m (25ft)
1/Pkg
CC525AC-050A
108036773
15.2m (50ft)
1/Pkg
In-Line (180) to Unterminated
76
CC525CN-050A
108036765
15.2m (50ft)
1/Pkg
CC525CN-100A
108301169
30.5m (100ft)
1/Pkg
CORDS
Copper
25-Pair Cords
Miscellaneous
Category 3 25-Pair Cords
Cords Contents Page
These 25-Pair (50-Pin) Telco Connector Cords consist of 0.511 mm (24 AWG) solid annealed copper conductors insulated with semi-ridged grey PVC. Single-ended, 25-Pair Connector Cables have one unconnectorised end and one connectorised end, either male or female. Double-ended 25-Pair Connector Cables are connectorised at both ends and are available either with both ends male, or one female end and one male end. These Telco cables are used to connect voice switching equipment, and Listed
data equipment operating at 10 Mb/s or less. They are UL listed type CMR.
Physical Specifications Gauge: 0.511mm (24 AWG)
Weight: 12.71 kg/100m
Outside Diameter: 9.6mm
Insulation Thickness: 0.15mm
Jacket Thickness: 0.63mm
Electrical Specifications DC Resistance: 9.38 Ω/100m Mut. Capacitance (@ 1kHz): 7.2 nF/100m Impedance (1.0-10 MHz): 100Ω ± 15% Attenuation (dB/100m): @ 1.0 MHz: 2.9 @ 4.0 MHz: 6.2 @ 10 MHz: 9.8 Delay at 1 kHz: 0.56 µs/100m
Comcode
Length
Connector Type
Packaging
A25B-10 SGL
100959139
3m (10ft)
Female to Unterminated
ea
A25B-15 SGL
100959162
4.6m (15ft)
Female to Unterminated
ea
A25B-25 SGL
100849918
7.6m (25ft)
Female to Unterminated
ea
A25B-50 SGL
100016765
15.2m (50ft)
Female to Unterminated
ea
A25D-10 SGL
100959931
3m (10ft)
Male to Unterminated
ea
A25D-15 SGL
100959949
4.6m (15ft)
Male to Unterminated
ea
A25D-25 SGL
100959964
7.6m (25ft)
Male to Unterminated
ea
A25D-30 SGL
100964014
9.1m (30ft)
Male to Unterminated
ea
A25D-50 SGL
100960004
15.2m (50ft)
Male to Unterminated
ea
A25D-100 SGL
101129484
30.5m (100ft)
Male to Unterminated
ea
A25D-10 DBL
100963982
3m (10ft)
Male to Male
ea
A25D-25 DBL
100959972
7.6m (25ft)
Male to Male
ea
B25A-10 DBL
101619336
3m (10ft)
Male to Female
ea
B25A-30 DBL
100017342
9.1m (30ft)
Male to Female
ea
B25A-60 DBL
100017359
18.3m (60ft)
Male to Female
ea
B25A-100 DBL
100017367
30.5m (100ft)
Male to Female
ea
CORDS
Product
77
CORDS
Copper
D8EX Cross-over Cords
Miscellaneous
Ethernet Crossover Cords The D8EX Cord is an 8-pin modular cord with pairs two and three crossed over at one end. It is composed of 1074 cordage and terminated on each end with an Avaya CM plug. It is designed for ethernet
CORDS
Listed
78
hub to hub connections. The cords are red in colour and are individually tested after manufacture.
Product
Comcode
Length
Packaging
Colour
D8CM Crossover
108879206
0.9m (3ft)
ea
Red
D8CM Crossover
108879198
1.5m (5ft)
ea
Red
D8CM Crossover
108879172
2.1m (7ft)
ea
Red
D8CM Crossover
108879180
4.3m (14ft)
ea
Red
Cords Contents Page
CORDS
Fibre
LC Cords
LazrSPEED™
Duplex 1.6mm Patch Cords
Cords Contents Page
At just 1.6mm in diameter, LazrSPEED, LC Patch Cords are the smallest in the industry. Test results by Avaya Labs per EIA/TIA 455 procedures and IEC 794 methods show the 1.6mm cordage exceeds the requirements for 3.0mm cordage. This smaller cordage allows at least twice as many fibres to be installed in a cabinet. The duplex cordage is 1.6 by 3.5 mm in a figure 8 design that has two single fibre cords joined together with a web. LC Patch Cords greatly reduce congestion in shelves to help you save space and time when rearranging cabling. Pull proof design helps
Figure 36 LC 1.6mm Cordage
prevent accidental disconnects and helps to assure optimal
ST 1.6mm Cordage
performance of your system. Custom hybrid Patch Cords
SC 1.6mm Cordage
are also available, to simplify your migration to industry leading SYSTIMAX® LC Connectors. Features: – Aqua LazrSPEED cordage for craft identification – Small diameter cordage provides robust, high density package – LC connectors are the lowest loss fibre optic connectors on the market
Physical Specifications Minimum Bandwidth @ 1300nm: 500Mhz.Km (laser), 500Mhz.Km (olf) Attenuation: 3.4 dB/Km @ 850nm, 1.0dB/Km @ 1300nm Cable Outside Diameter: 1.6mm Cable Outside Diameter: Simplex: 1.6mm Duplex: 1.6 x 3.7mm Min. Bend Radius: 2.5cm Operating Temperature Range: -20 to 70ºC
CORDS
Optical Specifications Average Connection Loss: LC = 0.1 dB Return Loss Minimum: 20 dB Tip Material: Ceramic Mating Durability for 500 Reconnects Insertion Loss Change: <0.2 dB Operating Temperature: -40 to + 75ºC Insertion Loss Change: <0.3 dB
79
CORDS
Fibre
LC Cords
LazrSPEED
Duplex 1.6mm Cordage Patch Cords The 1.6mm LazrSPEED Cordage provides a robust high density package. The LC connectors are the lowest loss fibre optic connectors on the market. Product
Comcode
Length
Connector Type
Fibre Type
Packaging
MZ2LC-LC-04
108573627
1.2m (4ft)
LC-LC
LZ MM
ea
MZ2LC-LC-06
108573635
1.8m (6ft)
LC-LC
LZ MM
ea
MZ2LC-LC-10
108573643
3m (10ft)
LC-LC
LZ MM
ea
MZ2LC-LC-20
108573650
6.1m (20ft)
LC-LC
LZ MM
ea
MZ2LC-LC-30
108573668
9.1m (30ft)
LC-LC
LZ MM
ea
MZ2LC-LC-40
108573676
12.2m (40ft)
LC-LC
LZ MM
ea
MZ2LC-LC-50
108573684
15.2m (50ft)
LC-LC
LZ MM
ea
Fibre
STII+ Cords
LazrSPEED
Duplex 1.6mm Cordage Patch Cords The Aqua colour identifies the 1.6mm LazrSPEED Cord as high density.
Optical Specifications Average Connection Loss: STII+ = 0.3 dB Return Loss Minimum: 20 dB Cable Outside Diameter: 1.6 mm Cable Retention (use with Avaya cable) (cordage): 20 lbs / 88.9 N
CORDS
Tip Material: Ceramic Mating Durability for 500 Reconnects Insertion Loss Change: <0.2 dB Temperature Stability: -40 to 75ºC Insertion Loss Change: <0.3 dB
80
Product
Comcode
Length
Connector Type
Fibre Type
Packaging
MZ2STII+-STII+-04
108688680
1.2m (4ft)
STII+-STII+
LZ MM
ea
MZ2STII+-STII+-10
108572710
3m (10ft)
STII+-STII+
LZ MM
ea
MZ2STII+-STII+-20
108572728
6.1m (20ft)
STII+-STII+
LZ MM
ea
MZ2STII+-STII+-30
108572736
9.1m (30ft)
STII+-STII+
LZ MM
ea
MZ2STII+-STII+-40
108688144
12.2m (40ft)
STII+-STII+
LZ MM
ea
MZ2STII+-STII+-50
108572744
15.2m (50ft)
STII+-STII+
LZ MM
ea
Cords Contents Page
CORDS
Fibre
STII Cords
LazrSPEED
3.0mm LazrSPEED Patch Cords
Cords Contents Page
LazrSPEED Patch Cords are available in 3.0mm cordage with STII connectors. Features: – Aqua LazrSPEED cordage for craft identification – 3.0mm OD Cordage Product
Comcode
Length
Connector Type
Fibre Type
Packaging
LZ2STII+-STII+-04
108573106
1.2m (4ft)
STII+ - STII+
LZ MM
ea
LZ2STII+-STII+-06
108573114
1.8m (6ft)
STII+ - STII+
LZ MM
ea
LZ2STII+-STII+-10
108573122
3m (10ft)
STII+ - STII+
LZ MM
ea
LZ2STII+-STII+-20
108573130
6.1m (20ft)
STII+ - STII+
LZ MM
ea
LZ2STII+-STII+-30
108573148
9.1m (30ft)
STII+ - STII+
LZ MM
ea
LZ2STII+-STII+-40
108573155
12.2m (40ft)
STII+ - STII+
LZ MM
ea
LZ2STII+-STII+-50
108573163
15.2m (50ft)
STII+ - STII+
LZ MM
ea
Fibre
SC Cords
LazrSPEED
3.0mm LazrSPEED Patch Cords LazrSPEED Patch Cords are also available in 3.0mm cordage with SC connectors. Features: – Aqua LazrSPEED cordage for craft identification – 3.0mm OD Cordage
Optical Specifications Average Connection Loss: SC = MM: 0.3 dB; SM: 0.2 dB (tuned); SM: 0.3 dB (untuned)
CORDS
Return Loss Minimum: -50 dB max Cable Outside Diameter: 3.0mm Cable Retention (use with Avaya cable) (cordage): 20 lbs / 88.9 N Tip Material: Ceramic Mating Durability for 500 Reconnects
Insertion Loss Change: <0.2 dB Temperature Stability: -20ºC to 70ºC
Product
Comcode
Length
Connector Type
Fibre Type
Packaging
LZ2SC-SC-04
108572777
1.2m (4ft)
SC - SC
LZ MM
ea
LZ2SC-SC-06
108572785
1.8m (6ft)
SC - SC
LZ MM
ea
LZ2SC-SC-10
108572793
3m (10ft)
SC - SC
LZ MM
ea
LZ2SC-SC-20
108572801
6.1m (20ft)
SC - SC
LZ MM
ea
LZ2SC-SC-30
108572819
9.1m (30ft)
SC - SC
LZ MM
ea
LZ2SC-SC-40
108572827
12.2m (40ft)
SC - SC
LZ MM
ea
LZ2SC-SC-50
108572835
15.2m (50ft)
SC - SC
LZ MM
ea 81
CORDS
Fibre
Hybrid Cords
LazrSPEED
Duplex LazrSPEED 1.6mm Hybrid Patch Cords
Cords Contents Page
The duplex cordage is 1.6 by 3.5 mm in a figure-8 design that has two single fibre cords joined together with a web. LC Patch Cords greatly reduce congestion in shelves to help you save space and time when rearranging cabling. Pull proof design helps prevent accidental disconnects and helps to assure optimal performance of your system. These hybrid LC to MT-RJ Patch Cords are to simplify your migration to industry leading SYSTIMAX LC Connectors. Features:
Figure 37
– Aqua LazrSPEED cordage for craft identification
to MTRJ
LC Connector attached
– Small diameter cordage provides robust,
CORDS
high density package
82
Product
Comcode
Length
Connector Type
Fibre Type
Packaging
MZ2LC-SC-04
108573783
1.2m (4ft)
LC-SC
LZ MM
ea
MZ2LC-SC-06
108573791
1.8m (6ft)
LC-SC
LZ MM
ea
MZ2LC-SC-10
108573809
3m (10ft)
LC-SC
LZ MM
ea
MZ2LC-SC-20
108574435
6.1m (20ft)
LC-SC
LZ MM
ea
MZ2LC-SC-30
108574443
9.1m (30ft)
LC-SC
LZ MM
ea
MZ2LC-SC-40
108574450
12.2m (40ft)
LC-SC
LZ MM
ea
MZ2LC-SC-50
108574468
15.2m (50ft)
LC-SC
LZ MM
ea
MZ2LC-STII+-04
108573502
1.2m (4ft)
LC-STII+
LZ MM
ea
MZ2LC-STII+-06
108573510
1.8m (6ft)
LC-STII+
LZ MM
ea
MZ2LC-STII+-10
108573528
3m (10ft)
LC-STII+
LZ MM
ea
MZ2LC-STII+-20
108573536
6.1m (20ft)
LC-STII+
LZ MM
ea
MZ2LC-STII+-30
108573544
9.1m (30ft)
LC-STII+
LZ MM
ea
MZ2LC-STII+-40
108573551
12.2m (40ft)
LC-STII+
LZ MM
ea
MZ2LC-STII+-50
108573619
15.2m (50ft)
LC-STII+
LZ MM
ea
MZ2LC-MJ-04
108573718
1.2m (4ft)
LC - MTRJ
LZ MM
ea
MZ2LC-MJ-06
108573726
1.8m (6ft)
LC - MTRJ
LZ MM
ea
MZ2LC-MJ-10
108573734
3m (10ft)
LC - MTRJ
LZ MM
ea
MZ2LC-MJ-20
108573742
6.1m (20ft)
LC - MTRJ
LZ MM
ea
MZ2LC-MJ-30
108573759
9.1m (30ft)
LC - MTRJ
LZ MM
ea
MZ2LC-MJ-40
108573767
12.2m (40ft)
LC - MTRJ
LZ MM
ea
MZ2LC-MJ-50
108573775
15.2m (50ft)
LC - MTRJ
LZ MM
ea
MZ2SC-SC-04
108688102
1.2m (4ft)
SC-SC
LZ MM
ea
MZ2SC-SC-06
108688110
1.8m (6ft)
SC-SC
LZ MM
ea
MZ2SC-SC-10
108574971
3m (10ft)
SC-SC
LZ MM
ea
MZ2SC-SC-20
108574997
6.1m (20ft)
SC-SC
LZ MM
ea
MZ2SC-SC-30
108575002
9.1m (30ft)
SC-SC
LZ MM
ea
MZ2SC-SC-40
108688128
12.2m (40ft)
SC-SC
LZ MM
ea
MZ2SC-SC-50
108575010
15.2m (50ft)
SC-SC
LZ MM
ea
CORDS
Fibre
Hybrid Cords
LazrSPEED
3.0mm LazrSPEED Patch Cords
Cords Contents Page
Hybrid LazrSPEED Patch Cords are available in 3.0mm cordage with STII and SC connectors. Features: – Aqua LazrSPEED cordage for craft identification – 3.0mm OD Cordage
Product
Comcode
Length
Connector Type
Fibre Type
Packaging
LZ2SC-STII-04
108572843
1.2m (4ft)
SC - STII+
LZ MM
ea
LZ2SC-STII-06
108572850
1.8m (6ft)
SC - STII+
LZ MM
ea
LZ2SC-STII-10
108573868
3m (10ft)
SC - STII+
LZ MM
ea
LZ2SC-STII-20
108572876
6.1m (20ft)
SC - STII+
LZ MM
ea
LZ2SC-STII-30
108572884
9.1m (30ft)
SC - STII+
LZ MM
ea
LZ2SC-STII-40
108572892
12.2m (40ft)
SC - STII+
LZ MM
ea
LZ2SC-STII-50
108572900
15.2m (50ft)
SC - STII+
LZ MM
ea
CORDS 83
CORDS
Fibre
OptiSPEED LC Connectors
OptiSPEED™
LC Fibre Cords
Cords Contents Page
The Best Little Connector in the Business…. The OptiSPEED LC Connector represents the latest innovation from Avaya Labs in the world of fibre connectivity. This best in class connector has a revolutionary physical and optical performance that allows for the quality build of fibre based networks. Benefits of this connector include: - The LC Small Form Factor means a space saving of 50%. - Allows for increased fibre density. Figure 38
- Superior optical performance allows for quality build of
Connector
High Data Rate Networks (Gigabit Ethernet). - Proven ceramic ferrule based technology offers the best in class connectivity in terms of optical performance, quality and reliability. - The new design reduces installation time by some 40%. - Cost effectivity is derived not only from the reduced installation time but also from the fact that the connector has a ruggedised solution for cordage and a standard solution for buffered fibre thus making the entire network solution cost effective. - A Complete Connectivity Solution covering, singlemode and multimode fibres in a simplex or duplex fashion. Effective colour coding of the jacket, inner jacket, buffer and connector ends enable ease of installation and administration. From the Innovators of the ST now comes the next generation
CORDS
connector…The LC.
Physical Specifications Coated Fibre Diameter: 250 µm
Cable Outside Diameter: Simplex: 1.6mm
Duplex: 1.6 x 3.7mm
Min. Bend Radius: 2.5cm
Operating Temperature Range: -20 to 70ºC
Optical Specifications Minimum Bandwidth @ 850nm: 200Mhz.Km
Minimum Bandwidth @ 1300nm: 500Mhz.Km
Attenuation: 3.4 dB/Km @ 850nm, 1.0B/Km @ 1300nm Average Connection Loss: LC = 0.1 dB Return Loss Minimum: 20 dB
Cable Outside Diameter: 1.6mm
Cable Retention (use with Avaya cable) (cordage): 20 lbs / 88.9 N
84
LC 1.6mm Jumper
Tip Material: Ceramic
Mating Durability for 500 Reconnects
Insertion Loss Change: <0.2 dB
Operating Temperature: -40 to + 75ºC
Insertion Loss Change: <0.3 dB
Minimum Bend Radius: 25cm (after installation)
CORDS
Fibre
LC Jumpers
OptiSPEED
LC Fibre Cords (contd)
Comcode
Fibre Count
Length
Fibre Type
Packaging
ML1LC-LC-04
107736712
1
1.2m (4ft)
OS MM
ea
ML1LC-LC-05
107736720
1
1.5m (5ft)
OS MM
ea
ML1LC-LC-06
107736738
1
1.8m (6ft)
OS MM
ea
ML1LC-LC-08
107736746
1
2.4m (8ft)
OS MM
ea
ML1LC-LC-10
107736753
1
3m (10ft)
OS MM
ea
ML1LC-LC-15
107736761
1
4.6m (15ft)
OS MM
ea
ML1LC-LC-20
107736779
1
6.1m (20ft)
OS MM
ea
ML1LC-LC-25
107736787
1
7.6m (25ft)
OS MM
ea
ML1LC-LC-30
107736795
1
9.2m (30ft)
OS MM
ea
ML1LC-LC-35
107736811
1
10.7m (35ft)
OS MM
ea
ML1LC-LC-40
107736829
1
12.2m (40ft)
OS MM
ea
ML1LC-LC-50
107736837
1
15.2m (50ft)
OS MM
ea
ML1LC-LC-75
107736845
1
22.9m (70ft)
OS MM
ea
ML1LC-LC-100
107736852
1
30.5m (100ft)
OS MM
ea
ML2LC-LC-02
107736886
2
0.6m (2ft)
OS MM
ea
ML2LC-LC-04
107736894
2
1.2m (4ft)
OS MM
ea
ML2LC-LC-05
107736910
2
1.5m (5ft)
OS MM
ea
ML2LC-LC-06
107736928
2
1.8m (6ft)
OS MM
ea
ML2LC-LC-08
107736936
2
2.4m (8ft)
OS MM
ea
ML2LC-LC-10
107736944
2
3m (10ft)
OS MM
ea
ML2LC-LC-15
107736951
2
4.6m (15ft)
OS MM
ea
ML2LC-LC-20
107736969
2
6.1m (20ft)
OS MM
ea
ML2LC-LC-25
107736977
2
7.6m (25ft)
OS MM
ea
ML2LC-LC-30
107736985
2
9.2m (30ft)
OS MM
ea
ML2LC-LC-35
107736993
2
10.7m (35ft)
OS MM
ea
ML2LC-LC-40
107737009
2
12.2m (40ft)
OS MM
ea
ML2LC-LC-50
107737017
2
15.2m (50ft)
OS MM
ea
ML2LC-LC-75
107737025
2
22.9m (70ft)
OS MM
ea
ML2LC-LC-100
107737033
2
30.5m (100ft)
OS MM
ea
MS1LC-LC-04
700003957
1
1.2m (4ft)
OS SM
ea
MS1LC-LC-05
700003940
1
1.5m (5ft)
OS SM
ea
MS1LC-LC-06
700003734
1
1.8m (6ft)
OS SM
ea
MS1LC-LC-08
700003932
1
2.4m (8ft)
OS SM
ea
MS1LC-LC-10
700003924
1
3m (10ft)
OS SM
ea
MS1LC-LC-15
700003726
1
4.6m (15ft)
OS SM
ea
MS1LC-LC-20
700003916
1
6.1m (20ft)
OS SM
ea
MS1LC-LC-25
700003908
1
7.6m (25ft)
OS SM
ea
MS1LC-LC-30
700003890
1
9.2m (30ft)
OS SM
ea
MS1LC-LC-35
700003684
1
10.7m (35ft)
OS SM
ea
CORDS
Product
Cords Contents Page
85
CORDS
Fibre
LC Jumpers
OptiSPEED
CORDS
LC Fibre Cords (contd)
86
Product
Comcode
Fibre Count
Length
Fibre Type
Packaging
MS1LC-LC-40
700003882
1
12.2m (40ft)
OS SM
ea
MS1LC-LC-50
700003718
1
15.2m (50ft)
OS SM
ea
MS1LC-LC-75
700003874
1
22.9m (70ft)
OS SM
ea
MS1LC-LC-100
700003866
1
30.5m (100ft)
OS SM
ea
MS2LC-LC-04
700003858
2
1.2m (4ft)
OS SM
ea
MS2LC-LC-05
700003841
2
1.5m (5ft)
OS SM
ea
MS2LC-LC-06
700003700
2
1.8m (6ft)
OS SM
ea
MS2LC-LC-08
700003833
2
2.4 m (8ft)
OS SM
ea
MS2LC-LC-10
700003692
2
3m (10ft)
OS SM
ea
MS2LC-LC-15
700003825
2
4.0 m (15ft)
OS SM
ea
MS2LC-LC-20
700003817
2
6 m (20ft)
OS SM
ea
MS2LC-LC-25
700003809
2
7.0 m (25ft)
OS SM
ea
MS2LC-LC-30
700003791
2
9.2m (30ft)
OS SM
ea
MS2LC-LC-35
700003783
2
10.7m (35ft)
OS SM
ea
MS2LC-LC-40
700003775
2
12.2m (40ft)
OS SM
ea
MS2LC-LC-50
700003767
2
15.2m (50ft)
OS SM
ea
MS2LC-LC-75
700003759
2
22.9m (70ft)
OS SM
ea
MS2LC-LC-100
700003742
2
30.5m (100ft)
OS SM
ea
Cords Contents Page
CORDS
Fibre
OptiSPEED 3.0mm STII+ Patch Cord
OptiSPEED
STII+ Fibre Cords
Cords Contents Page
The Simplex and Duplex STII+ Fibre Patch Cords are composed of 9000 Series, 3.0 mm cordage with pull-proof STII+ connectors terminated on each end. The cords are available in Simplex and Duplex and also in multimode and singlemode.
Physical Specifications Coated Fibre Diameter: 250 µm Cable Outside Diameter: Simplex: 3.0mm; Duplex: 6.6 x 3.6mm Min. Bend Radius: 3.8cm Operating Temperature Range: -20 to 70ºC
Optical Specifications MULTIMODE Ave. Loss: 0.3 dB/mated connector
Min. Bandwidth @ 850 nm: 200 MHz-km
Min. Bandwidth @ 1300 nm: 500 MHz-km SINGLEMODE Ave. Loss: 0.3 dB/mated connector
Return Loss: -50 dB Max
Comcode
Fibre Count
Length
Fibre Type
Packaging
FL1STII+-STII+-02
107150153
1
0.6m (2ft)
OS MM
ea
FL1STII+-STII+-04
107150161
1
1.2m (4ft)
OS MM
ea
FL1STII+-STII+-06
107150179
1
1.8m (6ft)
OS MM
ea
FL1STII+-STII+-08
107150187
1
2.4m (8ft)
OS MM
ea
FL1STII+-STII+-10
107150195
1
3m (10ft)
OS MM
ea
FL1STII+-STII+-15
107150203
1
4.6m (15ft)
OS MM
ea
FL1STII+-STII+-20
107150211
1
6.1m (20ft)
OS MM
ea
FL1STII+-STII+-25
107150229
1
7.6m (25ft)
OS MM
ea
FL2STII+-STII+-02
107150302
2
0.6m (2ft)
OS MM
ea
FL2STII+-STII+-04
107150310
2
1.2m (4ft)
OS MM
ea
FL2STII+-STII+-06
107150328
2
1.8m (6ft)
OS MM
ea
FL2STII+-STII+-08
107150336
2
2.4m (8ft)
OS MM
ea
FL2STII+-STII+-10
107150344
2
3m (10ft)
OS MM
ea
FL2STII+-STII+-15
107150351
2
4.6m (15ft)
OS MM
ea
FL2STII+-STII+-20
107150369
2
6.1m (20ft)
OS MM
ea
FL2STII+-STII+-25
107150377
2
7.6m (25ft)
OS MM
ea
FS1STII+-STII+-10
700011000
1
3m (10ft)
OS SM
ea
FS2STII+-STII+-04
700010994
2
1.2m (4ft)
OS SM
ea
FS2STII+-STII+-10
700010989
2
3m (10ft)
OS SM
ea
CORDS
Product
87
CORDS
Fibre
STII+ - STII+
OptiSPEED
1.6mm Cord
Cords Contents Page
The STII+ to STII+ Fibre Optic Cord features pull proof connectors and can be ordered in multimode or
CORDS
singlemode in either a simplex or duplex version.
88
Product
Comcode
Fibre
Length Count
Fibre Type
Packaging
ML1STII+-STII+-06
107486979
1
1.8m (6ft)
OS MM
ea
ML1STII+-STII+-10
107486995
1
3m (10ft)
OS MM
ea
ML2STII+-STII+-02
107487126
2
0.6m (2ft)
OS MM
ea
ML2STII+-STII+-04
107487134
2
1.2m (4ft)
OS MM
ea
ML2STII+-STII+-06
107487159
2
1.8m (6ft)
OS MM
ea
ML2STII+-STII+-08
107487167
2
2.4m (8ft)
OS MM
ea
ML2STII+-STII+-10
107487175
2
3m (10ft)
OS MM
ea
ML2STII+-STII+-15
107487183
2
4.6m (15ft)
OS MM
ea
ML2STII+-STII+-20
107487191
2
6.1m (20ft)
OS MM
ea
ML2STII+-STII+-25
107487209
2
7.6m (25ft)
OS MM
ea
CORDS
Fibre
OptiSPEED 3.0mm SC-SC Patch Cord
OptiSPEED
SC Fibre Cords
Cords Contents Page
The Simplex and Duplex SC Fibre Patch Cords are composed of 9000 Series, 3.0mm cordage with push-pull SC connectors terminated on each end. They are available in both Simplex and Duplex and also in multimode and singlemode.
Figure 39 SC Duplex Patch Cord
Physical Specifications Coated Fibre Diameter: 250 µm Cable Outside Diameter: Simplex: 3.0mm; Duplex: 6.6 x 3.6mm Min. Bend Radius: 3.8cm Operating Temperature Range: -20 to 70ºC
Optical Specifications MULTIMODE Mean Insertion Loss: 0.2 dB Max. Insertion Loss: 0.6 dB Connection Repeatability: < 0.2 dB change for 500 reconnections Minimum Bandwidth @ 850 nm: 200 MHz-km Minimum Bandwidth @ 1300 nm: 500 MHz-km SINGLEMODE Avg. Loss: 0.3 dB/mated connector Return Loss: -50dB Max
Comcode
Fibre Count
Length
Fibre Type
Packaging
LL1SC-SC-02
106908668
1
0.6m (2ft)
OS MM
ea
LL1SC-SC-04
106908676
1
1.2m (4ft)
OS MM
ea
LL1SC-SC-05
106908684
1
1.5m (5ft)
OS MM
ea
LL1SC-SC-10
106908692
1
3m (10ft)
OS MM
ea
LL1SC-SC-15
106908700
1
4.6m (15ft)
OS MM
ea
LL1SC-SC-20
106908718
1
6.1m (20ft)
OS MM
ea
LL1SC-SC-25
106908734
1
7.6m (25ft)
OS MM
ea
LL2SC-SC-02
107122616
2
0.6m (2ft)
OS MM
ea
LL2SC-SC-04
107122624
2
1.2m (4ft)
OS MM
ea
LL2SC-SC-05
107122632
2
1.5m (5ft)
OS MM
ea
LL2SC-SC-10
107122640
2
3m (10ft)
OS MM
ea
CORDS
Product
89
CORDS
Fibre
SC-SC
OptiSPEED
CORDS
SC Fibre Cords (contd)
90
Product
Comcode
Fibre Count
Length
Fibre Type
Packaging
LL2SC-SC-15
107122657
2
4.6m (15ft)
OS MM
ea
LL2SC-SC-20
107122665
2
6.1m (20ft)
OS MM
ea
LL2SC-SC-25
107122673
2
7.6m (25ft)
OS MM
ea
LS1SC-SC-04
700011059
1
1.2m (4ft)
OS SM
ea
LS1SC-SC-10
700011042
1
3m (10ft)
OS SM
ea
LS2SC-SC-05
700011026
2
1.5m (5ft)
OS SM
ea
LS2SC-SC-10
700011018
2
3m (10ft)
OS SM
ea
Cords Contents Page
CORDS
Fibre
OptiSPEED 1.6mm SC - SC Patch Cords
OptiSPEED
1.6mm Cords
Cords Contents Page
The SC to SC Fibre Optic uses 1.6mm cords feature pull proof connectors and can be ordered in multimode or singlemode in either a simplex or duplex version.
Product
Comcode
Fibre Count
Length
Fibre Type
Packaging
ML1SC-SC-02
107653990
1
0.6m (2ft)
OS MM
ea
ML1SC-SC-04
107670994
1
1.2m (4ft)
OS MM
ea
ML1SC-SC-05
107671000
1
1.5m (5ft)
OS MM
ea
ML1SC-SC-10
107671018
1
3m (10ft)
OS MM
ea
ML1SC-SC-15
107671026
1
4.6m (15ft)
OS MM
ea
ML1SC-SC-20
107671034
1
6.1m (20ft)
OS MM
ea
ML1SC-SC-25
107671042
1
7.6m (25ft)
OS MM
ea
ML2SC-SC-02
107671133
2
0.6m (2ft)
OS MM
ea
ML2SC-SC-04
107671158
2
1.2m (4ft)
OS MM
ea
ML2SC-SC-05
107671166
2
1.5m (5ft)
OS MM
ea
ML2SC-SC-10
107671182
2
3m (10ft)
OS MM
ea
ML2SC-SC-15
107671190
2
4.5m (15ft)
OS MM
ea
ML2SC-SC-20
107671208
2
6.1m (20ft)
OS MM
ea
ML2SC-SC-25
107671216
2
7.6m (25ft)
OS MM
ea
CORDS 91
CORDS
Fibre
Hybrid OptiSPEED Patch Cord
OptiSPEED
1.6mm LC-STII+ Cords
The Duplex LC to STII+ Patch Cords are composed of duplex 1.6mm cord with Avaya pull-proof STII+ connectors terminated on one end and LC connectors terminated on the other end.
Product
Comcode
Length
Fibre Type
Packaging
ML2LC-ST-4
108072430
1.2m (4ft)
OS MM
ea
ML2LC-ST-6
108072448
1.8m (6ft)
OS MM
ea
ML2LC-ST-10
108072455
3.0m (10ft)
OS MM
ea
ML2LC-ST-15
108072463
4.6m (15ft)
OS MM
ea
ML2LC-ST-30
108072471
9.0m (30ft)
OS MM
ea
Fibre
Hybrid OptiSPEED Patch Cord
OptiSPEED
1.6mm LC-SC Cords
The Duplex LC to SC Patch Cord are composed of duplex 1.6mm cord with Avaya SC connectors
CORDS
terminated on one end and LC connectors terminated on the other end.
92
Product
Comcode
Length
Fibre Type
Packaging
ML2LC-SC-4
108072406
1.2m (4ft)
OS MM
ea
ML2LC-SC-6
108072414
1.8m (6ft)
OS MM
ea
ML2LC-SC-15
108072422
4.6m (15ft)
OS MM
ea
MS2LC-SC-10
700010929
3m (10ft)
OS SM
ea
MS2LC-SC-20
700025612
6.5m (20ft)
OS SM
ea
Cords Contents Page
CORDS
Fibre
Hybrid OptiSPEED Patch Cord
OptiSPEED
1.6mm STII+-SC Cords
Cords Contents Page
The STII+ to SC Patch Cord provides connectivity of fibre optic equipment at cross-connect, interconnects, and information outlets. The average loss is 0.3 dB/mated connector. They are composed of 1.6mm cordage terminated at one end with pull proof STII+ connectors and SC connectors at the other end.
Product
Comcode
Fibre Count
Length
Fibre Type
Packaging
ML1STII+-SC-02
107755498
1
0.6m (2ft)
OS MM
ea
ML1STII+-SC-04
107755506
1
1.2m (4ft)
OS MM
ea
ML1STII+-SC-06
107755522
1
1.8m (6ft)
OS MM
ea
ML1STII+-SC-08
107755530
1
2.4m (8ft)
OS MM
ea
ML1STII+-SC-10
107755548
1
3m (10ft)
OS MM
ea
ML1STII+-SC-15
107755563
1
4.6m (15ft)
OS MM
ea
ML1STII+-SC-20
107755571
1
6.1m (20ft)
OS MM
ea
ML1STII+-SC-25
107755589
1
7.6m (25ft)
OS MM
ea
ML2STII+-SC-02
107755779
2
0.6m (2ft)
OS MM
ea
ML2STII+-SC-04
107755787
2
1.2m (4ft)
OS MM
ea
ML2STII+-SC-06
107755795
2
1.8m (6ft)
OS MM
ea
ML2STII+-SC-08
107755803
2
2.4m (8ft)
OS MM
ea
ML2STII+-SC-10
107755811
2
3m (10ft)
OS MM
ea
ML2STII+-SC-15
107755829
2
4.6m (15ft)
OS MM
ea
ML2STII+-SC-20
107755837
2
6.1m (20ft)
OS MM
ea
ML2STII+-SC-25
107755845
2
7.6m (25ft)
OS MM
ea
ML2SC-SC-30
107671224
2
9.15m (30ft)
OS MM
ea
ML2SC-SC-35
107671232
2
10.7m(35ft)
OS MM
ea
ML2SC-SC-40
107671240
2
12.2m (40ft)
OS MM
ea
ML2SC-SC-50
107671265
2
15.2m (50ft)
OS MM
ea
ML2SC-SC-75
107671273
2
22.9m (75ft)
OS MM
ea
ML2SC-SC-100
107671281
2
30.5m (100ft)
OS MM
ea
CORDS 93
CORDS
Fibre
Hybrid Patch Cords
OptiSPEED
STII+ - SC Patch Cord (3mm) These STII+ to SC Patch Cords are composed of 9000 Series, 3.0 mm cordage with pull-proof STII+
CORDS
connectors terminated on one end and SC connectors terminated on the other end.
94
Product
Comcode
FL1STII+-SC-02
Fibre Count
Length
Fibre Type
Packaging
107755126
1
0.6m (2ft)
OS MM
ea
FL1STII+P-SC-04 107755142
1
1.2m (4ft)
OS MM
ea
FL1STII+-SC-06
107755159
1
1.8m (6ft)
OS MM
ea
FL1STII+-SC-08
107755167
1
2.4m (8ft)
OS MM
ea
FL1STII+-SC-10
107755183
1
3m (10ft)
OS MM
ea
FL1STII+-SC-15
107755191
1
4.6m (15ft)
OS MM
ea
FL1STII+-SC-20
107755209
1
6.1m (20ft)
OS MM
ea
FL1STII+-SC-25
107755217
1
7.6m (25ft)
OS MM
ea
FL2STII+-SC-02
107755308
2
0.6m (2ft)
OS MM
ea
FL2STII+-SC-04
107755316
2
1.2m (4ft)
OS MM
ea
FL2STII+-SC-06
107755324
2
1.8m (6ft)
OS MM
ea
FL2STII+-SC-08
107755332
2
2.4m (8ft)
OS MM
ea
FL2STII+-SC-10
107755340
2
3m (10ft)
OS MM
ea
FL2STII+-SC-15
107755357
2
4.6m (15ft)
OS MM
ea
FL2STII+-SC-20
107755365
2
6.1m (20ft)
OS MM
ea
FL2STII+-SC-25
107755373
2
7.6m (25ft)
OS MM
ea
Cords Contents Page
CORDS
Fibre
OptiSPEED
Hybrid OptiSPEED Patch Cords
LC - MTRJ 1.6mm Cords
Cords Contents Page
The duplex LC - MTRJ Patch Cords are a hybrid patch cord that use duplex 1.6mm cordage.
Product
Comcode
Length
Fibre Type
Packaging
ML2LC-MJ-04
108462425
1.2m (4ft)
OS MM
ea
ML2LC-MJ-06
108462433
1.8m (6ft)
OS MM
ea
ML2LC-MJ-08
108462441
2.4m (8ft)
OS MM
ea
ML2LC-MJ-10
108462458
3m (10ft)
OS MM
ea
ML2LC-MJ-15
108462466
4.6m (15ft)
OS MM
ea
ML2LC-MJ-30
108462508
9.1m (30ft)
OS MM
ea
Fibre
Hybrid OptiSPEED Patch Cords
OptiSPEED
SC - MTRJ 1.6mm Cords
The duplex SC - MTRJ Patch Cords are a hybrid patch cord that use duplex 1.6mm cordage.
Comcode
Length
Packaging
ML2SC-MJ-04
108510033
1.2m (4ft)
ea
ML2SC-MJ-06
108510041
1.8m (6ft)
ea
ML2SC-MJ-08
108510058
2.4m (8ft)
ea
ML2SC-MJ-10
108510066
3m (10ft)
ea
ML2SC-MJ-15
108510074
4.6m (15ft)
ea
ML2SC-MJ-20
108510082
6.1m (20ft)
ea
ML2SC-MJ-25
108510090
7.6m (25ft)
ea
CORDS
Product
95
CORDS
Fibre
OptiSPEED
Hybrid OptiSPEED Patch Cords
STII+ - MTRJ 1.6mm Cords
CORDS
Duplex STII - MTRJ Patch Cords are a hybrid patch cord that use duplex 1.6mm cordage.
96
Product
Comcode
Length
Packaging
ML2STII+-MJ-04
108509910
1.2m (4ft)
ea
ML2STII+-MJ-06
108509928
1.8m (6ft)
ea
ML2STII+-MJ-08
108509936
2.4m (8ft)
ea
ML2STII+-MJ-10
108509944
3m (10ft)
ea
ML2STII+-MJ-30
108509985
9.1m (30ft)
ea
Cords Contents Page
CORDS
Fibre
LC Pigtails
Miscellaneous
Pigtails
Cords Contents Page
The LC Pigtails consist of strengthened buffer jacket single fibre cord with an LC connector terminated on one end. They are used for splicing to LGBC or Outside Plant fibres for termination in a fibre distribution shelf or LIU. Product
Comcode
Length
Fibre Type
Packaging
3LC-5
700006760
1.5m (5ft)
OS MM
ea
1LC-5
700010945
1.5m (5ft)
OS SM
ea
Fibre
SC Pigtails
Miscellaneous
Pigtails The SC Pigtails consist of a strengthened buffer jacket single fibre cord with a push-pull SC connector terminated on one end. They are used for splicing to LGBC or Outside Plant fibres for termination in a fibre distribution shelf or LIU.
Product
Comcode
Length
Fibre Type
Packaging
3SC-5
700003353
1.5m (5ft)
OS MM
ea
1SC-5
700011083
1.5m (5ft)
OS SM
ea
STII+ Pigtails
CORDS
Fibre
Miscellaneous
Pigtails The STII+ Pigtails consist of a strengthened buffer jacket single fibre cord with a pull proof STII+ connector terminated on one end. They are used for splicing to LGBC or Outside Plant fibres for termination in a fibre distribution shelf or LIU.
Product
Comcode
Length
Fibre Type
Packaging
3STP-1
700006794
0.3m (1ft)
OS MM
ea
3STP-5
700006786
1.5m (5ft)
OS MM
ea
1STP-5
700010978
1.5m (5ft)
OS SM
ea
97
CORDS
Fibre
Miscellaneous
Patch Cords Colour Codes
Patch Cords 3.0mm Pigtails, 1.6mm Cords
SIMPLEX CORDAGE F i b r e Ty p e
Fibre 1 Inner Jacket/Buffer Coat
Jacket
OptiSPEED SM
Black
Yellow
OptiSPEED MM
Blue
Grey
DUPLEX CORDAGE F i b r e Ty p e
Fibre 1 Inner Jacket/Buffer Coat
Fibre 2 Inner Jacket/Buffer Coat
Jacket
OptiSPEED SM
White/Black
Yellow/Black
Yellow
OptiSPEED MM
White/Blue
Yellow/Blue
Yellow
Fibre
Pigtails Colour Codes
Miscellaneous
Patch Cords 3.0mm Pigtails, 1.6mm Cords
CORDS
Mode
98
Jacket
MM
Grey
SM
Yellow
Cords Contents Page
CORDS
Fibre
Patch Cords Colour Codes
Miscellaneous
Patch Cords 3.0mm, Pigtails, 1.6mm Cords
Cords Contents Page
SIMPLEX CORDAGE F i b r e Ty p e
Fibre 1 Heat Shrink/Buffer Coat
Jacket
OptiSPEED SM
Black
Yellow
OptiSPEED MM
Blue
Grey
DUPLEX CORDAGE F i b r e Ty p e
Fibre 1 Heat Shrink/Buffer Coat
Fibre 2 Heat Shrink/Buffer Coat
Jacket
OptiSPEED SM
White/Black
Yellow/Red
Yellow
OptiSPEED MM
White/Blue
Yellow/Orange
Grey
CORDS 99
100
Panels Chapter
3
101
Panels Contents
Click Here Main Menu
Copper
Multimedia
1 1 0 FA M I LY
MULTIMEDIA
VisiPatch System ™
103
MultiMAX
105
Fibre
136
SHELVES VisiPatch
LIUs
1 1 0 FA M I LY VisiPatch
107
LazrSPEED™
137
110 Connector System
108
Interconnection Unit
138
Wiring Blocks
109
Accessories
140
Patch Panels
115
SHELVES
Jack Panels
117
Accessories
120
RJ45 PANELS
600ALS Combination Shelf 143 600BLS Combination Shelf 144 LSTLS High Density
iPatch System
125
1100 Fibre Distribution Panel 146
126
600A1 Shelf
147
1100GS Panels
127
600A1 Shelf Accessories
148
2500CAT5PS & 2512CAT5PS
600 Series Shelf Accessories 149
Panels
128
600B2 Shelf
150
Accessories
129
600B2 Shelf Accessories
151
FLEXIMAX Fleximax HD Panel
131
LGX Shelves
152
LGX Accessories
156
PATCH PANELS Introduction
132
PATCHMAX® GigaSPEED®
133
PATCHMAX PowerSum / OptiSPEED & LazrSPEED 134
102
145
1100PSE Panels
™
PANELS
Copper
VisiPatch
110 Family
110 VisiPatch™ System
Panels Contents Page
The Next Generation 110 Patch Panel System For High Speed Data Networks The SYSTIMAX® SCS 110 VisiPatch System is the “next generation” 110 Patch Panel System and the latest in a long line of Avaya Labs designed SYSTIMAX SCS innovations for high-speed data networks. The 110 VisiPatch System utilises time proven 110 IDC technology and features a unique “reverse direction” patch cord, integrated cable and patch cord management, increased density, wall mounting hardware, and snap together
Figure 43
installation. The neat, cordless appearance dramatically
VisiPatch System
improves patch cord organisation and management and “cleans up the clutter” that is inherent with other patch panel systems. Features
- Approved for GigaSPEED® and Power Sum Channels. - Innovative “Reverse Patch Cord” design.
Higher Density
- 28 conductor pairs per row (instead of 25). - 7 “4-pairs” (instead of 6). - 336 conductor pairs per back panel (instead of 300). - Snap-together installation, no new tools required. - Clean, neat, cordless appearance. - New colour scheme. - Integrated patch cord management. - Stackable back panel modules
Back Panel: Using space age plastic structural foam technology, this patented wall mounting hardware consists of two identical “L” shaped halves that snap together to form a strong “U” shaped panel. The lightweight panel can be easily mounted to the wall and becomes the Back Panel for the 110 VisiPatch System. The Back Panel holds 12 wiring blocks and is stackable.
PANELS
Wiring Block: The Wiring Block snaps on to the Back Panel and accepts 28 conductor pairs in the same space where traditional 110 Systems allow only 25. Slots and grooves provide versatile cable management, and seven 4-pair connecting blocks can be accommodated. Accepts 4 and 25-Pair Cables. Designation Strip/Cover Plate: The Cover Plate snaps directly on to the Wiring Block and provides protection for the terminated cables. It also serves as a Designation Strip for circuit identification, and facilitates the latching of the 4-pair patch cord.
103
PANELS
Copper
VisiPatch
110 Family
Field Termination Kit
PANELS
Description
104
Kit Quality
300PR Base, Back Panel Half
2
110UW-28, Wiring Block
12
110UC-28, Designation Cover
12
110C4W, Connecting Block
84
110UPHLDR, Label Holder
12
110WG3-2688L, White Label
12
Product
Comcode
110UB1-336FT VisiPatch 110 Kit
108561143
110UB1-112FT VisiPatch 110 Kit
108836792
110UPT-Kit - Trough
700012990
110UHPT-Uni. Horz. Trough
108836834
Designation Cover - Clear Plastic
108922360
HLDR-110FDLH New Label
108738113
Panels Contents Page
PANELS
Copper
VisiPatch™
Shelves
Horizontal Trough
Panels Contents Page
The 110 UHD-S8 Horizontal Trough attaches to the bottom of the VisiPatch panel.
Figure 44 VisiPatch Horizontal Trough
Product
Comcode
Packaging
110UHD-S8
108637737
1/Pkg
Copper
VisiPatch
Shelves
Wall Mounted Bracket The Wall Mounted Bracket allows for convenient mounting of the VisiPatch panel. It is discrete and durable. Product
Comcode
Packaging
BRKT-110PWB HGR STL
108688946
1/Pkg
PANELS 105
PANELS
Copper
VisiPatch
Shelves
Installation Spacer The Installation Spacer helps with the mounting of the brackets to ensure there is sufficient space to allow you to hang the panels correctly.
Product
Comcode
Packaging
SPCR-110UHS20BAR.063X1
108637612
1/Pkg
Copper
VisiPatch
Shelves
Trough Cover The 110UTC VisiPatch Trough Cover, compliments the sleek appearance of the VisiPatch System by providing a cover for the cords which are routed in the vertical troughs. This light grey cover conve-
PANELS
niently snaps over the distribution rings and gives the entire VisiPatch System a clean, cordless look.
Product
Comcode
Packaging
110UTC
108593203
1/Pkg
Copper
VisiPatch
Shelves
Mounting Bracket The 110U19M VisiPatch Bracket, is used to mount the VisiPatch 110 Field Termination Kit in a 19”singlesided frame. Four brackets are required to mount six 110UB1-336FT VisiPatch 110 Kits in a 19” singlesided frame. The back panels of the VisiPatch Kit easily mount directly on the tabs of these brackets without the use of screws.
106
Product
Comcode
Packaging
110U19M
108634429
1/Pkg
Panels Contents Page
PANELS
Copper
VisiPatch™
110 Family
Distribution Rings
Panels Contents Page
The Distribution Rings snap directly on to the back panel, provide improved vertical patch cord management density and eliminate the need to install traditional vertical cable management panels.
Product
Comcode
Description
Packaging
110U2R
108523937
Distribution Ring
1/Pkg
Copper
VisiPatch
110 Family
Designation Strip Labels The Designation Strip Labels are clipped onto the VisiPatch designation cover via a clear plastic holder.
Product
Comcode
Packaging
Colour
110YG3-2688L
108528407
96/Pkg
Yellow
110WG3-2688L
108528415
96/Pkg
White
110SG3-2688L
108528423
96/Pkg
Slate
110RG3-2688L
108528431
96/Pkg
Red
110PG3-2688L
108528449
96/Pkg
Purple
110GG3-2688L
108528456
96/Pkg
Green
110CG3-2688L
108528597
96/Pkg
Orange
110BG3-2688L
108528464
96/Pkg
Blue
110KG3-2688L
108528472
96/Pkg
Brown
PANELS
Copper
VisiPatch
110 Family
Replacement Kits This kit provides replacement connecting blocks and label holders.
Product
Comcode
Description
Packaging
110C4W
108538612
Connecting Block
10/Pkg
110UPHLDR
108540121
Label Holder
12/Pkg
107
PANELS
Copper
110 Connector System
110 Family
Introduction The 110-type wiring block is a fire-retardant, moulded plastic block consisting of four horizontal index Listed
strips designed to terminate 25 pairs of conductors each. These index strips are marked with the five tip colours on the high tooth to help separate the tip and ring of each pair and to establish pair location. The 110-type connecting block is a one piece, fire-retardant, moulded plastic assembly containing solder-plated insulation displacement quick clips. These clips are double-ended, with one end designed to accept cross-connect wire or patch cords and the other to terminate the cable conductors on the index strips of the wiring blocks. Once the wire is completely seated at the bottom of the wire slot, a permanent gas-tight contact is created. Plastic barbs in the wire slot provide mechanical strain relief to prevent accidental movement. The high teeth of the connecting block are marked with the ring colours. A slate strip is provided on the connecting block to assist in aligning the cutlets, and faces down for installation. The connecting blocks are available in three pair-count sizes; 110C-3, 110C-4, and 110C-5. The 110 system supports the GigaSPEED® and Power Sum solutions when used with the GigaSPEED or Power Sum cables and cords.
Physical Specifications Nom. Solid Conductor Diam.: 0.40 to 0.64mm (22 to 26 AWG) Nom. Stranded Conductor Diam.: 0.51 to 0.64mm (22 to 24 AWG) Termination Type: Insulation displacement, dry, gas tight Wire Retention Force (24 AWG): 59 -127 N
Wire Pullout Force (24 AWG): 9.7 N
Wire Retention Force, Horizontal (24 AWG): 36 N
Wire Retention Force, vertical (24 AWG): 9 N
Storage Temperature Range: -40 to 70ºC
Operating Temperature Range: -10 to 60ºC
Humidity: 95% Max. Conductor Termination: >200 Termination Speed: 100 pairs/20 mins
PANELS
Electrical Specifications
108
Dielectric Strength: ≥ 1kV rms
Capacitance Adjacent Contacts: < 1pF
Insulation Resistance: ≥ 100 MΩ
Termination Resistance (Typical): < 0.5 mΩ
Panels Contents Page
PANELS
Copper
Wiring Blocks
110 Family
The 110 Wiring Block is a fire-retardant moulded plastic
100-Pair & 300-Pair Wiring Blocks
Panels Contents Page
block with horizontal index strips each of which secures Listed
and organises 25 cable pairs. The index strips are marked with the five tip colours to help the installer locate pairs quickly. The blocks accommodate 0.643mm - 0.404mm (22 - 26 AWG) diameter conductors and can be mounted directly on wall surfaces. Figure 45
There are two types of 110 Wiring Blocks: “110A” Wiring Blocks and “110D” Wiring Blocks. The 110A Wiring Block
(a) 110AW2-100, (a)
110AW2-300,
is equipped with legs to provide space behind the block for
(b)
(b) 110DW2-100 and
routing the incoming cables. The 110D Wiring Block is built
110DW2-300
without legs and is used where depth is restrictive. Each
Wiring Blocks
type can be ordered in 100-pair or 300-pair sizes. There are several choices in ordering the 110 Wiring Blocks: - 110AW2 and 110DW2 are only the Wiring Blocks themselves, no accessories are included. - 110AA2, 110AB2, and 110AC2 are the Wiring Blocks with connecting blocks (A = 5-pair, B = 4-pair, and C = 3-pair), clear designation strips and blank labels. Please see the ACCESSORIES section of this chapter for associated products. The 110 Wiring Blocks can be used with patch cords to support Gigabit Data Rates or cross-connect wires up to 10 Mb/s. When using in patching applications, it is important to use a 110 Jumper Trough between each 100-pair block to allow for horizontal routing of patch cords. Backboards should also be used to neatly organise the vertical routing
The 110 Wiring Blocks exceed the Category 5 and Category
Physical Specifications
5e transmission NEXT requirements by at least 6 dB (See
Height: 100-Pair: 9.12cm;
of jumpers and patch cords.
Electrical Specifications) as defined in ISO/IEC IS11801, Hardware Section. The 110 system supports the GigaSPEED and Power Sum solutions when used with the GigaSPEED
PANELS
300-Pair: 27.41cm
CENELEC EN50173, and EIA/ TIA 568A Cross Connect
Width: A-Block: 27.23cm; D-Block: 21.60cm Depth: A-Block: 8.25cm; D-Block: 3.60cm
or Power Sum cables and cords. Product
Comcode
Pair Size
Packaging
110AW2-100
107059891
100
1/Pkg
110AW2-300
107059917
300
1/Pkg
110DW2-100
107059909
100
1/Pkg
110DW2-300
107059925
300
1/Pkg
110AB2-100FT
107058919
100
1/Pkg
110AB2-300FT
107058943
300
1/Pkg
110AC2-100FT
107058927
100
1/Pkg
110AC2-300FT
107058950
300
1/Pkg
109
PANELS
Copper
Wiring Blocks
110 Family
110 Troughs
Panels Contents Page
The 110 Jumper Trough is a white, fire-retardant, moulded plastic frame which is placed between each 100-pair wiring block and at the top of each column of 110 blocks. It serves as a horizontal trough for the routing of patch cords and cross-connect wire. The trough is available with legs (110A3 Trough) for use with the 110A Wiring Block or without legs (110B3 Trough) for use with the 110D Wiring Block or patch panel terminal block. Figure 46 110A2 and 110B1 Jumper Troughs
Physical Specifications Height: 6.83cm Width: 110A3: 27.30cm; 110B3: 21.60cm
PANELS
Depth: 110A3: 13.91cm; 110B3: 8.83cm
110
Product
Comcode
Legs
Packaging
110A3
107831133
Yes
1/Pkg
110B3
107831141
No
1/Pkg
PANELS
Copper
Wiring Blocks
110 Family
188 Backboards
Panels Contents Page
The 188B1 Backboard is used next to or between 110A Wiring Blocks to arrange jumper wires running between adjacent blocks. It is constructed of metal with two plastic distribution rings for neat horizontal or vertical routing of the jumper wires. The 188B2 Backboard is identical to the 188B1 Backboard except that the 188B2 has legs to allow space for routing cables behind the Backboard. Figure 47 188B2 and 188B1 Backboards
Physical Specifications Height: 16.50cm Width: 27.30cm Depth: 188B1: 8.90cm; 188B2: 11.45cm
Product
Comcode
Legs
Packaging
188B1
102689569
No
1/Pkg
188B2
104405113
Yes
1/Pkg
PANELS 111
PANELS
Copper
Wiring Blocks
110 Family
Disconnect Blocks
Panels Contents Page
The 110 Disconnect Terminal Block is a 110-type Wiring Block which permits circuit isolation without removing patch cords or cross-connect wire. The “look both ways” testing capabilities allow end-users to identify out-of-service lines and other circuit conditions easily. The 110 Disconnect Terminal Block, which has the same footprint as the 110DW2 Wiring Block, includes the 110C-4 or 110C-5 Connecting Block (noted with a “B” or “A,”
Figure 48
respectively, in the code) and provides for termination of
110TB2-50 Disconnect
50-pairs. The 110W4A4 test cord is available for test
Block, 110A1 & 110C1 Insulators,
purposes with the Disconnect Block.
110W4A4 Test Cord
The 110 Disconnect Terminal Block exceeds the Category 3 transmission requirements as defined in ISO/IEC IS11801 (1995), CENELEC EN50173 (1995), and meets or exceeds Category 4 requirements as defined in EIA/TIA 568A (1995) Cross Connect Hardware Section.
Physical Specifications Height: 9.11cm Width: 21.6cm
PANELS
Depth: 3.60cm
112
Product
Comcode
Pair Size
Packaging
110TA1-50
106274749
50
1/Pkg
110TB2-50
106569908
50
1/Pkg
PANELS
Copper
Wiring Blocks
110 Family
110B1 Insulator
Panels Contents Page
The 110B1 Insulator is an accessory to the 110 Disconnect Block which is used to open the circuit of a single pair on the 25-pair strip. It is made of fire-retardant moulded plastic, similar to that of the disconnect block.
Physical Specifications Height: 1.38cm Depth: 2.27cm
Product
Comcode
Pair Size
Packaging
110B1
106310618
1
50/Pkg
Copper
Wiring Blocks
110 Family
110W4A4 Test Cord The 110W4A4 Test Cord is used with the 110 Disconnect Block to open a 1-pair circuit and test all four conductor ends independently.
Physical Specifications Length: 1m
Comcode
Pair Size
Packaging
110W4A4
106310659
1
1/Pkg
PANELS
Product
113
PANELS
Copper
Wiring Blocks
110 Family
110CAT5 Connectorised Terminal Block
The Avaya Category 5e Power Sum 110 Connector system
Panels Contents Page
may be used in equipment rooms and telecommunications closets for connecting circuits and LAN electronics. They are backward compatible with existing 50-pin 525 connectors. They also fit with the 525 connectorised cable assemblies listed in the cordage section of this catalogue. These pre-connectorised blocks have the same footprint as the current 110 Wiring Block and the 110 Patch Panel Figure 49
Terminal Blocks with easy to install features.
110 CAT5e Connectorised
In addition to ease of installation and timesavings, these
Terminal Block
pre-connectorised blocks should reduce the potential for wiring errors that could interfere with the performance of the circuit.
Physical Specifications 50-Pair:
Height: 9.12cm
450-Pair: Height: 156.72cm
Width: 27.23cm
Width: 21.6cm
Depth: 8.5cm
Depth: 20.45cm
150-pair: Height: 62.69cm Width: 21.6cm
PANELS
Depth: 20.45cm
114
Frequency MHz
Power Sum NEXT (dB)
Attenuation (dB)
Return Loss (dB)
1
75
0.01
48
4
69
0.01
47
8
64
0.02
43
10
62
0.02
41
16
58
0.02
37
20
56
0.03
35
25
54
0.03
33
31.25
52
0.04
31
62.5
46
0.11
24
100
40
0.16
18
Product
Comcode
Pair Size
Packaging
110ABCAT5-50C
107764193
50
1/Pkg
110PBCAT5-150C
107764201
150
1/Pkg
110PBCAT5-450C
107764219
450
1/Pkg
PANELS
Copper
Patch Panels
11 0 Family
110 Patch Panels
Panels Contents Page
The 110 Patch Panel System comes in two sizes, 300-pair and 900-pair. They consist of a combination of 110D Wiring Blocks (100-pair) and 110B1 Jumper Troughs to be field mounted on a metal back panel which is designed to provide routing of the incoming cables behind the 110 blocks and troughs. The 110 Patch Panel System comes complete with 110C Connecting Blocks (in either 3, 4, or 5-pair modularity), clear designation strips, blank white labels, and grounding hardware. The 188-type backboard
Figure 50
should be ordered separately.
110PB2-300FT Patch Panel and
The 110 Patch Panel System is best mounted directly on
188D3 Backboard
the wall, but can be mounted in a 19” rack using the 110RP1-19-600 Bracket. When mounted in a 19" rack, the 300 or 900-pair patch panel can be mounted next to a 188-type backboard or next to another 110 Patch Panel. When two patch panels are mounted side-by-side in a 19” rack, there should be a facility for vertical patch cord management such as the 110A2 Distribution Rings. The 110 Patch Panel System exceeds the Category 5 and Category 5e transmission requirements (See Electrical Specifications) as defined in ISO/IEC IS11801, CENELEC EN50173, and EIA/TIA 568A Cross Connect Hardware Section. The 110 system supports the GigaSPEED and Power Sum solutions when used with the GigaSPEED Listed
or Power Sum cables and cords.
Physical Specifications Height: 300-pair: 62.69cm; 900-pair: 156.72cm Width: 21.60cm
Product
Comcode
Pair Size
Conn. Block Size
Packaging
110PA2-300FT
107058802
300
5 pairs
1/Pkg
110PA2-900FT
107058851
900
5 pairs
1/Pkg
110PB2-300FT
107058810
300
4 pairs
1/Pkg
110PB2-900FT
107058869
900
4 pairs
1/Pkg
110PC2-300FT
107058828
300
3 pairs
1/Pkg
110PC2-900FT
107058877
900
3 pairs
1/Pkg
PANELS
Depth: 20.45cm
115
PANELS
Copper
Patch Panels
110 Family
188 Backboards
Panels Contents Page
The 110 Patch Panel System Backboard is a metal panel equipped with distributing rings that provide the vertical paths for running patch cords or jumpers between 110 Patch Panel System Terminal Blocks. The 188D3 is used with a 300-pair patch panel while the 188C3 is used with the 900-pair patch panel.
Figure 51 110PB2-900FT Patch Panel and 188C3 Backboard
Physical Specifications Length: 188C3: 156.84cm; 188D3: 61cm Width: 21.60cm
PANELS
Depth: 20cm
116
Product
Comcode
Pair Size
Packaging
188D3
107151193
300
1/Pkg
188C3
107151185
900
1/Pkg
PANELS
Copper
Jack Panels
110 Family
110 Block
Panels Contents Page
The 110 Jack Panel Blocks provide 12 or 36 RJ45 interfaces, patchable via 110-type connecting blocks. The 110 Jack Panel Blocks consist of the Avaya 110 insulation displacement connector (IDC) field and RJ45 modular jack field mounted on the front of a printed wiring board (PWB). The 110 IDC is connected to the RJ45 modular jack through PWB interconnections. The PWB with 110 IDC’s and RJ45’s are mounted on either a 100-pair or 300-pair 110 Wiring Block with legs to provide 12 or 36 RJ45 jacks. The reference codes for the Jack Panel Blocks with legs are
Figure 52
110AB-CAT5PS-JP12 and 110AB-CAT5PS-JP36 for 12 and
110AB-CAT5PS-JP12
36 ports respectively.
Jack Panel
There is also the 110BB-CAT5PS-JP12FTB Jack Panel Kit which comes complete with a 110DW1-100 Wiring Block (without legs), the same PWB assembly as described above, and clips for mounting on the metal backpanel of the 110 Patch Panel Terminal Block. Shipped loose, the wiring block must first be mounted on the backpanel, then the PWB mounted on the wiring block. The Avaya 110 Jack Panel Blocks exceed the Category 5 and Category 5e transmission requirements as defined in Listed
ISO/IEC IS11801, CENELEC EN50173, and EIA/TIA 568A.
Physical Specifications Insertion Life: 750 cycles min. Plug/Jack Contact Force: 100 g min. Plug Retention Force: 133 N min. Operating Temperature Range: 0 to 60ºC Storage Temperature Range: -40 to 66ºC Humidity: 5 to 95% (noncondensing)
PANELS
Height: JP12: 9.12cm; JP36: 27.4cm Width: 27.2cm Depth: 8.4cm
Electrical Specifications DC Resistance: < 0.2 Ω
DC Resistance Unbalance: < 30 mΩ
117
PANELS
Copper
Jack Panels
110 Family
PANELS
110 Block (contd)
118
Frequency MHz
Worst Pair Attenuation (dB)
Worst Pair NEXT (dB)
Worst Pair Return Loss (dB)
1
0.06
81.0
44.0
4
0.07
70.6
41.0
8
0.07
64.7
36.0
10
0.08
62.8
34.0
16
0.09
58.8
33.0
20
0.10
56.9
30.0
25
0.11
54.9
28.0
31.25
0.12
53.1
26.0
62.5
0.17
47.2
22.0
100
0.29
42.5
20.0
Product
Comcode
Ports
Packaging
110AB-CAT5PS-JP12
107920704
12x RJ45
1/Pkg
110AB-CAT5PS-JP36
107920712
36x RJ45
1/Pkg
110BB-CAT5PS-JP12FTB
107920738
12x RJ45
1/Pkg
Panels Contents Page
PANELS
Copper
Jack Panels
110 Family
110 Panels
Panels Contents Page
The 110 Jack Panels provide 36 or 108 RJ45 interfaces Listed
patchable via 110-type connecting blocks. The 110 Jack Panel Blocks consist of the Avaya 110 insulation displacement connector (IDC) field and RJ45 modular jack field mounted on the front of a printed wiring board (PWB). The 110 IDC is connected to the RJ45 modular jack through PWB interconnections. The PWB with 110 IDC's and RJ45’s are mounted on 100-pair wiring blocks without legs, then mounted on a patch panel frame with jumper troughs placed between each 100-pair Jack Panel Block. The 110
Figure 53
Jack Panels are available in 300-pair and 900-pair versions
110PB-CAT5JP36
containing 36 or 108 ports respectively.
Jack Panel
The Avaya 110 Jack Panels exceed the Category 5 and Category 5e transmission requirements as defined in ISO/IEC IS11801, CENELEC EN50173, and EIA/TIA 568A.
Physical Specifications Insertion Life: 750 cycles min.
Height: JP36: 62.69cm; JP108: 156.72cm
Plug/Jack Contact Force: 100 g min.
Depth: 20.45cm
Plug Retention Force: 133 N min.
Width: 21.6cm
Operating Temperature Range: 0 to 60ºC Storage Temperature Range: -40 to 66ºC Humidity: 5 to 95% (noncondensing)
Electrical Specifications DC Resistance: < 0.2Ω
DC Resistance Unbalance: < 30 mΩ
Worst Pair Attenuation (dB)
Worst Pair NEXT (dB)
Worst Pair Return Loss (dB)
1
0.06
81.0
44.0
4
0.07
70.6
41.0
8
0.07
64.7
36.0
10
0.08
62.8
34.0
16
0.09
58.8
33.0
20
0.10
56.9
30.0
25
0.11
54.9
28.0
31.25
0.12
53.1
26.0
62.5
0.17
47.2
22.0
100
0.29
42.5
20.0
Product
Comcode
Ports
Packaging
110PB-CAT5PS-JP36B
107920720
36 x RJ45
1/Pkg
110PB-CAT5PS-JP108B
107920746
108 x RJ45
1/Pkg
PANELS
Frequency MHz
119
PANELS
Copper
Accessories
110 Family
188UT1 Label Holder
Panels Contents Page
The 188UT1 Label Holder is a clear plastic strip which snaps onto the 110 Wiring Block and accepts coloured insert labels for pair or circuit designation. When attached to the 110 Wiring Block, the Label Holder conceals and protects the cable conductor terminations. The Label Holders come in packages of six, while two Label Holders are required for 100 pairs. Pre-printed coloured labels should be ordered separately.
Figure 54 188UTI Label Holders
Physical Specifications Height: 1.45cm Width: 20.0cm
Product
Comcode
Packaging
188UT1-50
103895504
6/Pkg
Copper
Accessories
11 0 Family
Labels The 110 Insert Labels are coloured paper inserts (for the 188UT1 Label Holder) with vertical lines spaced to identify the circuits on a 110 Wiring Block. The labels listed below identify the circuits with
PANELS
4-pair modularity and come in colours of white and blue. Additional colours (yellow, grey, red, purple, green, orange and brown) are available in 3, 4, and 5-pair modularity on a non-stock basis. Please contact your authorised SYSTIMAX SCS representative for ordering information. The Insert Labels come in sheets of 24cm by 28cm which can be pin wheel printer fed.
Physical Specifications Height: 1.2cm Width: 20.0cm
Product
120
Comcode
Packaging
Colour
110BB2-4500L
106657174
90/Pkg
Blue
110WB2-4500L
106657216
90/Pkg
White
110GB2-4500L
106657182
90/Pkg
Green
110PB2-4500L
106657190
90/Pkg
Purple
110YB2-4500L
106657232
90/Pkg
Yellow
PANELS
Copper
Accessories
110 Family
110A2 Distribution Ring
Panels Contents Page
The 110A2 Distribution Ring is a moulded plastic attachment which clips on to either side of the 110 Wiring Block. It functions as a vertical patch cord or jumper organiser.
Physical Specifications Figure 55
Height: 1.4cm
110A2 Distribution Ring
Width: 6.99cm
mounted on a
Depth: 8.26cm
110AW2-100 Wiring Block
Product
Comcode
Packaging
110A2
107214405
1/Pkg
Copper
Accessories
11 0 Family
88A2 Retainer The 88A2 Retainer is a moulded plastic attachment which clips onto the legs of the 110AW2-100/300 Wiring Blocks. It is used to retain the cross-connect wires at the top or bottom corners of a column of the wiring block.
PANELS
Physical Specifications Height: 5.08cm Width: 2.54cm
Figure 56
Depth: 1.27cm
88A2 Retainer
Product
Comcode
Packaging
88A2
107267452
1/Pkg
121
PANELS
Copper
Accessories
110 Family
110C Connecting Blocks
Panels Contents Page
The Avaya 110C Connecting Blocks are one piece, fire-retardant, moulded plastic housings containing double-ended, solder plated quick clips with insulation displacement capabilities. The rear or cable side of the connector is designed to mount on the 110 index strip and terminate 0.643mm - 0.404mm (22 - 26 AWG) insulated conductors without prior removal of the insulation. The front side of the connector is designed to accept F Cross Connect Wire or 110 Patch Cords. The top of the Connecting Block is stamped with the product code, while the colour
Figure 57
code on the high teeth is provided to allow for pair
110C-3, 110C- 4 and
identification during installation.
110C-5 Connecting Blocks
The 110C Connecting Blocks come in three different pair sizes; 110C-3 is 3-pair, 110C-4 is 4-pair, and 110C-5 is 5-pair. The Avaya 110C Connecting Blocks exceed the Category 5 and Category 5e NEXT requirements @ 100 MHz as defined in ISO/IEC IS11801, CENELEC EN50173, and EIA/TIA 568A. The 110 system supports the GigaSPEED and Power Sum solutions when used with the GigaSPEED or Power Sum Listed
cables and cords.
Physical Specifications Height: 0.8cm Width: 3-p: 2.3cm; 4-p: 3.1cm; 5-p: 3.8cm
PANELS
Depth: 2.8cm
122
Product
Comcode
Pair Size
Packaging
110C-3
103801239
3
10/Pkg
110C-4
103801247
4
10/Pkg
110C-5
103801254
5
10/PkgPS/GS
PANELS
Copper
Accessories
110 Family
110RD2 19 Inch Bracket
Panels Contents Page
The 110RD2-200-19” Mounting Brackets are used for mounting the 110-type hardware in a 19” frame rack or data cabinet. Specifically, the 110RD2-200-19 Mounting Bracket mounts two 110DW2-100 Wiring Blocks and two 110B1 Troughs. Cable support rings on the rear of the bracket, secure cable routed through openings in the Mounting Bracket to the wiring blocks. Cross-connect wire or patch cords are routed from the wiring blocks through the troughs to the side of the frame to facilitate wire management. These Mounting Brackets can be mounted one on
Figure 58
top of the other to support pair requirements. Wiring
110RD2-200-19
blocks, troughs, and rivets must be ordered separately.
Mounting Brackets
Physical Specifications Height: 17.78cm Width: 48.3cm Depth: 1.27cm
Product
Comcode
Pair Size
Packaging
110RD2-200-19
107535585
200
1/Pkg
Copper
Accessories
110 Family
110A1 Wall Mounting Bracket The 110A1 Hanger Brackets will accommodate up to five 110 Patch Panels and/or 110 Patch Panel Backboards (188C3
PANELS
or 188D3). Two 110A1 Hanger Brackets should be mounted directly on the wall and the 110 Patch Panel apparatus are hung from the brackets.
Physical Specifications Figure 59
Width: 110.5cm
110A1 Bracket
Product
Comcode
Packaging
110A1 Bracket
104032230
1/Pkg
123
PANELS
Copper
Accessories
110 Family
Rivet Kit
Panels Contents Page
The 110RA-38 contains 38 white plastic push-in rivets which are designed to hold the 110 Wiring Block or Jumper Trough onto a 110 Patch Panel System backmount panel or 110RD2-200-19 Bracket. These are the same rivets which are included with the 110 Patch Panel System.
Physical Specifications Height: 1.1cm Width: 1.1cm
Figure 60
Depth: 2.54cm
Rivets
Product
Comcode
Packaging
110RA-38
107611634
38/Pkg
Copper
Accessories
110 Family
Test Cord The D Test Cord is a 1-pair cord used to provide access for testing purposes to a single pair of wires terminated on the 110 Connector System. The D Test Cord is equipped with a
PANELS
locking feature on the plug.
Figure 61 AT-8662 Test Cord
Product
124
Comcode
Length
Packaging
AT-8662
402023949
1.2m (4ft)
1/Pkg
AT-8662D
402023956
2.4m (8ft)
1/Pkg
PANELS
Copper
iPatch™ System
RJ45 Panels
RJ45 Panels
Panels Contents Page
The SYSTIMAX iPatch System integrates GigaSPEED ®
®
hardware and software to give real-time, at a glance control of all telecom room connections. Every port connection is continuously monitored, verified and logged in a central database. Work orders are issued to slash administration time. Work is guided at each patch panel by electronic visual and audio prompts to virtually eliminate wiring errors. The iPatch Rack Manager Each rack in the telecom room is controlled by a Rack Manager. It continuously monitors every port in the rack to
Figure 62
verify port usage, update the database, and notify you of
iPatch 1100PS Panels
problems the instant they occur. It also displays instructions to help technicians make changes quickly and accurately. Features - Monitors all patch connections and disconnection’s - Does not require proprietary patch cords - Guides technicians making patch connections - One-touch patch cord tracing speeds administration - Instantly reports improper connections to minimise service interruptions - Verifies the location, availability and use of ports on patch panels and jacks in faceplates. - Tracks services provided to each desktop - Eliminates tedious paperwork such as generating work orders and tracking scheduled changes. - Unmatched GigaSPEED performance. PANELS Product
Comcode
Ports
Packaging
iP1100PS24
108650185
24 x RJ45
1/Pkg
iP1100GS24
108650193
24 x RJ45
1/Pkg
108650201
48 x RJ45
1/Pkg
iP1100GS48
108650219
48 x RJ45
1/Pkg
PANELS
iP1100PS48
COMPONENTS Product
Description
Comcode
Packaging
iPRCKMGR-NA
iPatch Rack Manager (NA)
108 666 017
1/Pkg
iPRCKMGR-UK
iPatch Rack Manager (UK)
108 666 025
1/Pkg
iPRCKMGR-EU
iPatch Rack Manager (EU)
108 666 033
1/Pkg
iPNETMGR-NA
iPatch Network Manager (NA)
108 665 985
1/Pkg
iPNETMGR-UK
iPatch Network Manager (UK)
108 665 993
1/Pkg
iPNETMGR-EU
iPatch Network Manager (EU)
108 666 009
1/Pkg
iPSMNETMGR-NA
iPatch Network Manager w/System Manager software (NA)
700 023 005
1/Pkg
iPSMNETMGR-UK
iPatch Network Manager w/System Manager software (UK)
700 023 013
1/Pkg
iPSMNETMGR-EU
iPatch Network Manager w/System Manager software (EU)
700 023 021
1/Pkg
iPPWRSPLY-NA
Power Supply (NA)
108 650 672
1/Pkg
iPPWRSPLY-UK
Power Supply (UK)
108 650 706
1/Pkg
iPPWRSPLY-EU
Power Supply (EU)
108 650 714
1/Pkg 125
PANELS
Copper
1100PSE Panels
RJ45 Panels
1100CAT5PS Panels
Panels Contents Page
The 1100PSE Modular Jack Panel is a 19 inch rack mountable RJ45 jack panel. The 1100 PSE accommodates repeated line moves, additions and rearrangements. The IDC connection on the rear of the panel houses the printed wiring board that provides continuous connection to the 8-pin modular jacks on the front. The result is a hard-working panel that allows a gas-tight termination of equipment on 110 connecFigure 63
tors. The panel is available with 24, 32, 48, 64 or 96 RJ45
1100CAT5PS-24 and
ports. The 1100PSE Panel kit includes new icon labels with
1100CAT5PS-48 Panels
plastic holders that you can mount on the front of the panel for easy port identification. The 1100PSE has an enclosed PWB for protection. Cable tie slots on each end of each 6-port module allow for the use of cable ties (provided) to secure the cable at the edge of the module. The panel is capable of handling either T568A or T568B wiring; you simply select the appropriate label and wire the product as either A or B depending on your customer requirements. The 1100PSE panel is a member of the Power Sum solution. It exceeds the Category 5 and Category 5e requirements in ISO/IEC 11801 CENELEC EN 50173 and TIA/EIA-568A. The Listed
1100PSE panels are UL listed.
Physical Specifications Insertion Life: 750 cycles min. Plug/Jack Contact Force: 100 g min. Plug Retention Force: 133 N min. Operating Temperature Range: 0 to 60ºC Storage Temperature Range: -40 to 66ºC
PANELS
Humidity: 5 to 95% (noncondensing) Height: 24-Ports: 4.38cm (1u); 32-Ports: 8.83cm (2u); 48-Ports: 8.83cm (2u); 64-Ports 17.7cm (4u) Width: 48.26cm (19 inch) Depth: 4.06cm
126
Product
Comcode
Ports
Packaging
1100CAT5PS-24
108208919
24xRJ45
1/Pkg
1100CAT5PS-32
108208927
32xRJ45
1/Pkg
1100CAT5PS-48
108208935
48xRJ45
1/Pkg
1100CAT5PS-64
108208943
64xRJ45
1/Pkg
1100CAT5PS-96
108208950
96xRJ45
1/Pkg
PANELS
Copper
1100GS Panels
RJ45 Panels
1100GS Panels
Panels Contents Page
The 1100GS Modular Jack Panel is a 19 inch rack mountable RJ45 jack panel. The 1100GS accommodates repeated line moves, additions and rearrangements. The IDC connection on the rear of the panel houses the printed wiring board that provides continuous connection to the 8-pin modular jacks on the front. The result is a hard-working panel that allows a gas-tight termination of equipment on 110 connectors. The panel is available with 24, 32, 48, 64 or 96 RJ45 ports. The 1100GS Panel kit includes voice (telephone) and data (computer) labels in blue and white with plastic holders that you can mount on the front of the panel for easy
Figure 64
port identification.
1100GS Panels
The 1100GS has an enclosed PWB for protection. Cable tie slots on each end of each 6-port module allow for the use of module. The panel is capable of handling either T568A or
Physical Specifications
T568B wiring; you simply select the appropriate label and
Insertion Life: 750 cycles min.
wire the product as either A or B depending on your
Plug/Jack Contact Force: 100 g min.
customer requirements.
Plug Retention Force: 133 N min.
cable ties (provided) to secure the cable at the edge of the
The 1100GS Panel forms an integeral part of the GigaSPEED solution product portfolio. The GigaSPEED Solution is guaranteed to meet the Category 6/Class E Channel
Operating Temperature Range: 0 to 60ºC Storage Temperature Range: -40 to 66ºC Humidity: 5 to 95% (noncondensing) Height: 24-Ports: 4.38cm (1u);
Specifications proposed for IS0/IEC and TIA, even under
32-Ports: 8.83cm (2u);
the worst case channel configuration (100 meters, including
48-Ports: 8.83cm (2u);
four connections). Note that in all cases the GigaSPEED
64-Ports: 17.7cm (4u)
channel specifications meet or exceed the Category 6/Class
Width: 48.26cm (19 inch)
E proposed specifications. The 1100GS Panels are UL listed.
Depth: 4.06cm
Comcode
Ports
Packaging
1100GS2-24
108619420
24xRJ45
1/Pkg
1100GS2-32
108619438
32xRJ45
1/Pkg
1100GS2-48
108619453
48xRJ45
1/Pkg
1100GS2-64
108619479
64xRJ45
1/Pkg
1100GS2-96
108619487
96xRJ45
1/Pkg
PANELS
Product
127
PANELS
Copper
2500CAT5PS and 2512CAT5PS Panels
RJ45 Panels
2500PS Panels
Panels Contents Page
The 2500CAT5 Modular Jack Panel is a 19 inch rack mountable RJ45 Category 5 jack panel with 25-pair female 525 connectors on the back. The 25-pair 525 connectors are connected to the 4-pair RJ45 modular jacks through Printed Wiring Board (PWB) interconnections. The 2500CAT5PS follows the standard EIA T568B and T568A wiring scheme. The panel is available with 24 or 48 RJ45 ports.
Figure 65 2500CAT5PS
The 2512CAT5PS, unlike the 2500CAT5PS, provides two pairs to each 8-pin modular jack. These pairs are terminated on pins 1 and 2 and 3 and 6. Therefore, one 50-pin connector serves 12 jacks. The 2500CAT5PS Modular Jack Panel meets or exceeds the Category 5 transmission requirements for attenuation and worst pair-to-pair NEXT as defined in ISO/IEC IS11801, CENELEC EN50173, and EIA/TIA 568A. The 2512CAT5PS is wired to the IEEE 802.3, Ethernet 100BASE-TX and Listed
10BASE-T Standard.
Physical Specifications Insertion Life: 750 cycles min. Plug/Jack Contact Force: 100 g min. Plug Retention Force: 133 N min. Operating Temperature Range: 0 to 60ºC Storage Temperature Range: -40 to 66ºC Humidity: 5 to 95% (noncondensing) Height: 24-Ports: 4.38cm (1u); 48-Ports: 8.83cm (2u) Width: 48.26cm (19“)
PANELS
Depth: 4.06cm
128
Product
Comcode
Ports
Wiring Scheme
Packaging
2500CAT5PS-24B
108236142
4x Telco to 24x RJ45
T568B
1/Pkg
2500CAT5PS-48B
108236159
8x Telco to 48x RJ45
T568B
1/Pkg
2512CATPS-48
108236167
4x Telco to 48x RJ45
Pairs 2 & 3
1/Pkg
PANELS
Copper
Accessories
RJ45 Panels
Patch Cord Organisers
Panels Contents Page
The 1100D Patch Cord Organisers are used for routing patch cords in 19 inch rack mount RJ45 Jack Panel installations. There are three different Patch Cord Organisers available; the 1100D2-35-19 which provides horizontal routing via metal distribution rings and the 1100D1-35-19 which similarly provides horizontal routing but with the addition of 24 small plastic clips to provide for vertical pathways. The 1100D3-35-19 also provides horizontal routing via
Figure 66
metal rings on the front and cable routing on the rear.
1100D1-35-19, 1100D235-19 and 1100D3-35-19
The 1100D1 and 1100D2 are both 2u high and the 1100D3 is
Patch Cord Organisers
1u high.
Physical Specifications Height: 8.89cm; 1100D3: 4.38cm Width: 1100D1: 50.8cm; 1100D2: 48.3cm; 1100D3: 48.3cm Depth: 1100D1: 11.43cm; 1100D2: 9.53cm; 1100D3: 11.7cm
Product
Comcode
Packaging
Colour
1100D1-35-19
106830615
1/Pkg
Black
1100D2-35-19
106830623
1/Pkg
Black
1100D3-35-19
107132664
1/Pkg
Black
PANELS 129
PANELS
Copper
Accessories
RJ45 Panels
1100C Wall Adapter
Panels Contents Page
The 1100C Wall Adapters are used to mount panels (e.g. 1100 panels) onto any flat surface. Hinges provide easy access to the rear of the panel without removing the unit. The adapters can be mounted so that it hinges from the right or left side. The snap-lock pin holds the panel in place once the unit is installed.
Figure 67 1100C1 Wall Adapters
Physical Specifications 1100C1-35-19 Wall Adapter:
Height: 8.89cm Width: 48.3cm Depth: 12.7cm
1100C1-70-19 Wall Adapter:
Height: 17.78cm Width: 48.3cm
PANELS
Depth: 12.7cm
130
Product
Comcode
Packaging
Colour
1100C1-35-19
106830573
1/Pkg
Black
1100C1-70-19
106830581
1/Pkg
Black
PANELS
Copper
Fleximax HD Panel
Fleximax
HD Panel
Panels Contents Page
The FlexiMAX HD Panel is a 24-port panel that allows for patching or interconnects in the telecommunications closet or equipment room. It is an RJ45 1u modular panel specifically designed for the GigaSPEED® solution but can also be used for Power Sum applications. The panel is available in a 24-port version only and can hold up to 24 high-density distribution modules (not included). The front appearance of the panel comprises two rows of square punchouts, which allow ease of access for HDMs. Figure 68
The benefits of this panel include:
Fleximax HD panel
- Its 1u height makes it possible to maximise office space - Colour coding is possible by use of coloured outlets - It is possible to include a mixture of Power Sum/ GigaSPEED. - A bend has been incorporated in the top and bottom to minimise the flex.
Physical Specifications Height: 4.35cm (1u) Width: 48.20cm (19inch) Depth: 8.00cm
Product
Comcode
Packaging
Colour
Fleximax HD
108356312
1/Kg
Black
PANELS 131
PANELS
Copper
Introduction
Patch Panels
PATCHMAX® GigaSPEED,® Power Sum and OptiSPEED™
Panels Contents Page
The Avaya PATCHMAX Distribution Hardware is a modular patch panel system designed by Avaya Labs. Its unique patented modular construction provides a customer configurable GigaSPEED, Power Sum (RJ45) and OptiSPEED Fibre Patch Panel interface. The PATCHMAX Distribution Hardware consists of a 19 inch rack mountable aluminium panel designed to accept
incorporating GigaSPEED distribution
currently available in two configurations. The DM2150 has
module and
six 4-pair RJ45 modular jacks on the front wired to six 110
OptiSPEED
The DM2250 similarly has six 4-pair RJ45 modular jacks on the front, but these jacks are wired to a 25-pair telco connector on the rear via a printed wiring board. The Distribution Modules snap into the panels providing quick field assembly. The unique mounting arrangement allows the modules to rotate in the panel providing front access to the IDC terminations or telco connector. Cords and cables are managed and routed via the R2100 (front) and R2200 (rear) Retainers which are integral to the panels. The front mounted R2100 Retainer routes cords and functions as a cradle for the Distribution Module, allowing the installer to terminate and inspect the IDC or telco from the front without having to disconnect anything. The R2200 Retainer is a rear cable management bar which manages and routes cables on the back of the panel. Both retainers snap into the panel without any mounting screws. There are velcro straps on both the front and back for additional cable security if required. The GigaSPEED PATCHMAX Modular universal panels
PANELS
PATCHMAX Panel
either four or eight Distribution Modules (DM’s), which are
IDC terminals on the rear via a printed wiring board.
are also available with universal wiring. The panels can be wired for either T568A or T568B; simply select the appropriate “A” or “B” labels and wire the panel based on customer requirements. Identification labels are shipped with each panel and slide into grooved slots in the front of the Distribution Module. Coloured reversible icon strips, with a telephone on one side and a computer on the other, can be ordered separately in various colours. The OptiSPEED PATCHMAX Panels are available in ST, SC and hybrid ST-SC and SC-ST adapter assemble for multimode applications. These fibre module additions provide the same look in the closet or the equipment room as well as providing a compact termination method.
132
Figure 69
(ST-ST and SC/SC) distribution module
PANELS
Copper
PATCHMAX GigaSPEED
Patch Panels
PATCHMAX
Panels Contents Page
PATCHMAX GigaSPEED Distribution Hardware is designed for superior, reliable link performance. The compact modular design of this distribution hardware assures reliable performance, compatibility and fast, easy installation. Design features include: - Superb electrical performance when mated with low variability GigaSPEED cords. - A choice of 24 and 48-port rack-mounted panels with Figure 70
distribution modules (DMs) designed to accommodate
PM2151-24GS and
either standard pinout (T568A or T568B).
DM2151-GS Distribution Modules
- Unique, rotating distribution module design ensures fast, easy installation and easy access to the back. - Designed for simplified administration with built-in cord and cable retainer rings, colour-coded labels and icons. The PATCHMAX GigaSPEED forms an integral part of the GigaSPEED Solution product portfolio. The GigaSPEED Solution is guaranteed to meet the Category 6/Class E Channel Specifications proposed for ISO/IEC and TIA, even under the worst case channel configuration (100 meters, four connections). Note that in all cases the GigaSPEED channel specifications meet or exceed the Listed
Category 6/Class E proposed specifications.
Physical Specifications 4-Module Panel: Height: 8.9cm (2u) Width: 48.3cm Depth: 20.5cm 8-Module Panel: Height: 17.78cm (4u) Width: 48.3cm Depth: 20.5cm Modular Jack: 750 minimum (without retainer): Height: 8.9cm (2u) Width: 48.3cm Depth: 3.2cm 48 Port Panel (without retainer): Height: 17.78cm (4u) Width: 48.3cm Depth: 12.7cm Operating Temperature Range: -10°C to 70°C Storage Temperature Range: - 40°C to 6°C
PANELS
Humidity: 95% (noncondensing) EIA/TIA Category: 5 Nom. Solid Conductor Diam.: 0.40 to 0.64mm (22 to 26 AWG) Nom. Stranded Conductor Diam.: 0.4 to 0.64mm (22 to 26 AWG) Insulation Size: 1.27mm (0.050") Maximum DOD Insulation Types: All plastic insulants (including PVC, irradiated PVC, Polyethylene, Polypropylene, PTF Polyurethane, Nylon, and Teflon Nominal Attenuation (dB) Reterminations: IDC: 200 minimum Modular Jack: 750 minimum
Product
Comcode
Wiring
Ports
Packaging
PM2160GS-24
108619347
Universal
24x RJ45
1/Pkg
PM2160GS-48
108619362
Universal
48x RJ45
1/Pkg
DM2160GS Module
108619511
Universal
6x RJ45
24/Pkg
PM2250B-24
107882342
Universal
24
1/Pkg
PM2250B-48
107882367
Universal
48
1/Pkg
133
PANELS
Copper
PATCHMAX Power Sum
Patch Panels
Power Sum Accessories
Panels Contents Page
The Power Sum performance margin of PATCHMAX PSE ensures your network will be ready for today’s applications and emerging technology such as 1000Base-T Gigabit Ethernet using parallel transmission schemes. The PATCHMAX PSE hardware meets or exceeds the Category 5 transmission requirements for attenuation and NEXT as defined in ISO/IEC IS11801, CENELEC EN50173, and EIA/TIA 568A. Further, it is UL Listed and meets the Listed
Category 5e requirements. Figure 71 PM2150-48 and PM2150-24 Panel Kits
Physical Specifications Modular Jack: 750 Minimum (without retainer): Height: 8.9 cm (2u) Width: 48.3 cm Depth: 3.2 cm 48 Port Panel (without retainer): Height: 17.78 cm (4u) Width: 48.3 cm Depth: 12.7 cm Operating Temperature Range: -10°C to 70°C Storage Temperature Range: -40°C to 60°C Humidity: 95% (noncondensing) EIA/TIA Category: 5 Nom. Solid Conductor Diam.: 0.40 to 0.64 mm (22 to 26 AWG) Nom. Stranded Conductor Diam.: 0.4 to 0.64 mm (22 to 26 AWG) Insulation Size: 1.27 mm (0.050") Maximum DOD Insulation Types: All plastic insulants (including PVC, irradiated PVC, Polyethylene, Polypropylene, PTF Polyurethane, Nylon, and Teflon Nominal Attenuation (dB)
Reterminations: IDC: 200 minimum
PANELS
Modular Jack: 750 minimum
134
Product
Comcode
Description
Packaging
Colour
PM2150-48
108320045
PATCHMAX Kit w. 48 x RJ45, Universal Wiring
1/Pkg
Black
PM2150-24
108320029
PATCHMAX Kit w. 24 x RJ45, Universal Wiring
1/Pkg
Black
P2040
107428591
Panel for 4 Distribution Modules
1/Pkg
Black
P2080
107428609
Panel for 8 Distribution Modules
1/Pkg
Black
DM2150
108320011
Distribution Module, 6x RJ45, Universal Wiring
24/Pkg
Black
DM2250B
107882326
Distribution Module, 25-pair to RJ45
1/Pkg
Black
PM2250B-24
107882342
Panel Kit, 25-pair to RJ45 B Wiring - 24 Port
1/Pkg
Black
PM2250B-48
107882367
Panel Kit, 25-pair to RJ45 B Wiring - 48 Port
1/Pkg
Black
PANELS
Copper
PATCHMAX Power Sum
Patch Panels
Power Sum Accessories (contd) Product
Listed
Comcode
Description
Packaging
Panels Contents Page
Colour
R2100A
108036690
Front Retainer
5/Pkg
Black
R2200
107638934
Rear Retainer
1/Pkg
Silver
R2300
107670952
Fastener Kit, Velcro Wrap
1/Pkg
Black
L2300-BL
107536773
Icon Strip (6 Icons per Strip)
4/Pkg
Blue
L2300-BR
107536831
Icon Strip (6 Icons per Strip)
4/Pkg
Brown
L2300-GN
107536781
Icon Strip (6 Icons per Strip)
4/Pkg
Green
L2300-GY
107536765
Icon Strip (6 Icons per Strip)
4/Pkg
Grey
L2300-OR
107536807
Icon Strip (6 Icons per Strip)
4/Pkg
Orange
L2300-PL
107536849
Icon Strip (6 Icons per Strip)
4/Pkg
Purple
L2300-RD
107536815
Icon Strip (6 Icons per Strip)
4/Pkg
Red
L2300-WH
107536823
Icon Strip (6 Icons per Strip)
4/Pkg
White
L2300-YL
107536899
Icon Strip (6 Icons per Strip)
4/Pkg
Yellow
Label Sheet
107656910
Labelling Sheets (32x 6-circuit modules)
2/Pkg
Grey
Label Sheet
107656928
Labelling Sheets (32x 6-circuit modules)
2/Pkg
Blue
Label Sheet
107656936
Labelling Sheets (32x 6-circuit modules)
2/Pkg
Green
Label Sheet
107656951
Labelling Sheets (32x 6-circuit modules)
2/Pkg
Orange
Label Sheet
107656969
Labelling Sheets (32x 6-circuit modules)
2/Pkg
Red
Label Sheet
107656977
Labelling Sheets (32x 6-circuit modules)
2/Pkg
White
Label Sheet
107656985
Labelling Sheets (32x 6-circuit modules)
2/Pkg
Brown
Label Sheet
107656993
Labelling Sheets (32x 6-circuit modules)
2/Pkg
Purple
PANELS 135
Panels p91-p142.qxd
24/05/2001
11:47
Page 121
PANELS
Fibre
PATCHMAX® OptiSPEED™
Patch Panels Fibre Panel Kits
Panels Contents P
A selction of fibre termination modules is now available to order. These modules are available with ST, SC, LC and hybrid STSC and SC-ST adapter assemblies for multimode applications - the
first connector designation is what is found on the front of the module. For customers that want the aesthetics of the PATCHMAX panel and modules, as well as the functionality of the system, the fibre module additions provide the same look in the closet or the equipment room as well as providing a compact Figure 66
termination method.
PATCHMAX OptiSPEED
Fibres can be terminated in the same panel with copper pairs if
LC / LC panel
the requirements are small, or separate panels can be used for the fibre and the copper. Access to the modules can be from the front, or from the rear of the panel, with the fibre distribution modules resting in the front retainer rings as is done with copper terminations. The PATCHMAX fibre panel kits contain all the parts necessary to complete the installation of the OptiSPEED hardware excluding the connectors.
Figure 67
PATCHMAX fibre distribution modules can be ordered separately.
PATCHMAX OptiSPEED
The fibre distribution modules have the ports numbered 1
SC /SC panel
through 6, have areas for labels and icons to be attached, and incorporate a slack storage tray in the rear of the module which also maintains the correct bend radius for the buffered fibre. The fibre adapters used for PATCHMAX ST, SC and LC modules provide the same low connection loss that the ST, SC and LC couplings and adapters have when used in other cabinets, shelves, and panels. Panels, front retainer rings, rear retainer bar, Velcro straps, icons, and labels are the same pieces found in the original hardware sold for the copper solution.
24 and 48 port panels (48 or 96 for LC) are available. They hold 4 or 8 snap-in six port modules respectively. Individual fibre distribution modules are available when additions to a panel are desired. Guidelines on the cable routing and slack requirements in the rear of the panel are illustrated in the instruction sheet that is included with the PATCHMAX fibre panel kits. Products
Comcode
Packaging
Mode
PATCHMAX Fibre Panel Kits* PM2302 SC/SC-24
Listed
108118027
1/Pkg
MM
PM2302 ST/ST-24
108118068
1/Pkg
MM
PM2302 SC/SC-48
108118100
1/Pkg
MM
PM2302 ST/ST-48
108118142
1/Pkg
MM
SYSTIMAX® SCS Product
Panels p91-p142.qxd
24/05/2001
11:47
Page 122
PANELS
Fibre
PATCHMAX OptiSPEED
Patch Panels
Fibre Panel Kits Product
Comcode
Packaging
Mod e
PM 2302 LC/LC-48
108267659
1/Pkg
MM
PM 2302 LC/LC-96
108267675
1/Pkg
MM
PM 2303 LC/LC-48
108267667
1/Pkg
SM
PM 2303 LC/LC-96
108267683
1/Pkg
SM
PM 2302 SC/ST-24
108118043
1/Pkg
MM
PM 2302 ST/SC-24
108118084
1/Pkg
MM
PM 2302 SC/ST-48
108118126
1/Pkg
MM
PM 2302 ST/SC-48
108118167
1/Pkg
MM
1/Pkg
MM
PATCHMAX Fibre Distribution Modules* DM 2302 SC/SC DM 2302 ST/ST
108116526
1/Pkg
MM
DM 2302 SC/ST
108116500
1/Pkg
MM
108116542
1/Pkg
MM
DM 2302 LC/LC
108267634
1/Pkg
MM
DM 2303 LC/LC
108267642
1/Pkg
SM
PANELS
DM 2302 ST/SC
SYSTIMAX® SCS Product Guide
122
108116484
Panels Contents P
Panels p91-p142.qxd
24/05/2001
12:20
Page 121
PANELS
Fibre
PATCHMAX LazrSPEED™
PATCHMAX
Fibre Panel Kits
Panels Contents P
LazrSPEED PATCHMAX distribution hardware provides a common look and feel with GigaSPEED and PowerSUM PATCHMAX panels, allowing your network to grow and change without investing in an entirely new patch panel system. As your fibre cabling demands grow, installers simply add LazrSPEED PATCH-
MAX panels equipped with STII+, SC or LC adapter moudles.
Figure 66
PATCHMAX LazrSPEED
Constructed of lightweight aluminum PATCHMAX panels comply with the Electronic Industries Association (EIA) RS-310D standard for 19-inch (48.2cm) frames. The panels mount on either a 19-inch rach/frame or 1100C-type wall mounted brackets. PATCHMAX fibre distribution modules are equipped with LC, STII+ and SC adapters for mazimum flexibility. Each ST or SC distribution moudle handles 6 fibres, while the LC distrubiton module handles 12 fibres. Distribution moudles snap into the panles, allowing quick field assembly and easy installation. Mouldes can be added, removed or service mounted in the panel without special tools. A fibre slack tray attaches to the rear of the moudle to provide slack storage and maintain proper bend radius. The distribution module and slack tray are removable from the front of the panel, allowing easy access to the rear connectors and cable. In addition each moudle uses new hinge-mounted, flip-up dust covers to protect the adapter ports
Products
Co m c o d e
Packaging
Mode
PATCHMAX 2U Termination Shelf Kits
Listed
PM2304LC/LC-48
108662024
1/Pkg
MM
PM2304SC/SC-24
108662065
1/Pkg
MM
PM2304ST/ST-24
108662107
1/Pkg
MM
Products
Comcode
Packaging
Mode
PATCHMAX 4U Termiantion Shelf Kits PM2304LC/LC- 96
108662040
1/Pkg
MM
PM2304SC/SC-48
108662081
1/Pkg
MM
PM2304ST/ST- 48
108662123
1/Pkg
MM
SYSTIMAX® SCS Product
PANELS
M u l t i m e d i a MultiMAX
Multimedia
Distribution Panel
Panels Contents Page
The M1000P5 MultiMax Panel is a 19 inch rack mountable aluminium panel that provides for patching or interconnect in the telecommunications closet or equipment room. Packaged with the panel are mounting clips for up to 24 modular outlets or fibre connectors, distribution rings for cord or cable management and screws. For copper terminations, the mounting clips provide a Figure 72
fixture for holding the M-series HDM’s when terminating
M1000P5 MultiMAX Panel
conductors and also provide strain relief for the cable when snapped into the panel. Mounting clips also accommodate the M81ST and M81SC for fibre terminations.
Physical Specifications Height: 8.9cm Width: 48.3cm
PANELS
Depth: 0.32cm
136
Product
Comcode
Wiring
Packaging
Colour
M1000P5
108006198
24x HDMs
1/Kg
Black
PANELS
Fibre
LazrSPEED™
LIUs
LIUs
Panels Contents Page
LazrSPEED Interconnect Units (LIUs) are modular enclosures providing cross-connect and/or interconnect, splicing and terminating capabilities for outside plant and building cables. Although primarily designed as wall mounted units, they can be placed on a rack using a mounting bracket. The 100LS LIU can terminate 12 fibres with ST or SC connectors, or 24 fibres with LC connectors. With an optional splicing kit it can accommodate up to 12 mechanical or fusion splices. Made of an engineered polycarbonate material, the 100LS can accommodate two 10P adapter
Figure 73
panels (ordered separately)
LazrSPEED LIU’s
The 200LS LIU can terminate 24 fibres with ST or SC connectors, or 48 fibres with LC connectors. It can accommodate up to 12 mechanical or fusion splices, using an optional splicing kit. The 200LS can accommodate up to 24 mechanical or fusion splices with optional splicing kits, but the fibre termination capacity is decreased to 12 ST or SC connections, or 24 LC connections. The 200LS is made of aluminum and can accommodate four 10P adapter panels (ordered separately).
Physical Specifications 100LS LIU: Height:
22.2cm
Width:
19.1cm
Depth:
7.6cm
200LS LIU: Height:
22.2cm
Width:
19.1cm
Depth:
10.2cm
Comcode
Packaging
10PLC-LS
108627266
1/Pkg
10PSC-LS
108627274
1/Pkg
10PST-LS
108627282
1/Pkg
PANELS
Product
137
PANELS
Fibre
Interconnection Unit
LIUs
100A3 Unit
Panels Contents Page
The 100A3 Interconnection Unit (LIU) is a modular Listed
enclosure that provides cross-connect, interconnect, or splicing capabilities for Building Cables (LGBC) or Outside Plant cables inside a building. Two windows are provided to mount connector panels. The 100A3 is ideal for wall mounting and is made of durable engineered polycarbonate material. It is designed to terminate a maximum of 12 fibres for cross connection or interconnection, or can accommodate up to 12 mechanical (CSL) or fusion splices using the optional splice adapter tray.
Figure 74 100A3
The 100A3 LIU has five plastic split rings for managing
Interconnect Unit
slack fibres within the unit and two rings for routing cables passing through the unit. Termination posts at the top and bottom secure the cables entering from overhead or below. The 100A3 LIU has inserts to enclose cable entry holes and grommets to seal around the cables.
Physical Specifications Height: 22.22cm Width: 19cm
PANELS
Depth: 7.62cm
138
Product
Comcode
Connector/ Splice Qty
Packaging
100A3 LIU
106896947
12
1/Pkg
PANELS
Fibre
Interconnection Unit
LIUs
200A Unit
Panels Contents Page
The 200A Interconnection Unit (LIU) is a modular Listed
enclosure that provides cross-connect, interconnect or splicing capabilities for Building Cables (LGBC) or Outside Plant cables inside a building. Four windows are provided to mount connector panels. The 200A is ideal for wall mounting and is made of durable lightweight aluminium. It is designed to terminate a maximum of 24 fibres for cross connection or interconnection, or can accommodate up to 24 mechanical (CSL) or fusion splices using the optional splice adapter tray. The 200A can also accommodate a combination of 12 terminations and 12 splices.
Figure 75 200A Interconnect Unit
The 200A LIU has five plastic split rings for managing slack fibres within the unit and two rings for routing cables passing through the unit. Termination posts at the top and bottom secure the cables entering from overhead or below.
Physical Specifications Height: 22.22cm Width: 19cm Depth: 10.16cm
Product
Comcode
Connector/Splice Qty
Packaging
200A LIU
105535926
24
1/Pkg
PANELS 139
PANELS
Fibre
Accessories
LIUs
Panels
Panels Contents Page
The 10A, 10SC1, 10SC1-Duplex, 10LC1 and Blank Panels are designed for use in the 100A3 and 200A Interconnect Units (LIUs). The 10A accommodates up to 6 ST-type couplings (C2000A-2); the 10SC1 accommodates up to 6 SC-type couplings (C6000A-4); the 10SC1-Duplex accommodates up to 3 Duplex SC-type couplings (C6060A-4); the 10LC1 accommodates up to 6 Duplex LC-type couplings (C1000A-2) and the Blank Panel is intended to fill any empty panel slot in the 100A3 or 200A where the other panels are not required.
Figure 76 Blank and 10A Panels
Physical Specifications Height: 9.8cm Width: 3.7cm Depth: 0.3cm
PANELS
Product
140
Comcode
Ports
Packaging
10A
104141858
6x ST cpl
1/Pkg
10SC1
106371800
6x SC cpl
1/Pkg
10SC1-DPLX
107025835
3x Dplx SC
1/Pkg
10LC1
107783755
6x Dplx LC cpl
1/Pkg
Blank Panel
105276570
N/A
1/Pkg
PANELS
Fibre
Accessories
LIUs
1A4 Vertical Trough
Panels Contents Page
The 1A4 Fibre Optic Trough is a vertical aluminium trough which is used to arrange fibre patch cords vertically from one Interconnect Unit (LIU) to another in a multiunit fibre cross-connect, or from the LIU to the active electronics. The 1A4 is packaged with two mounting screws for wall mounted applications.
Physical Specifications Height: 22.2cm Width: 10.2cm
Figure 77
Depth: 5.1cm
1A4 Vertical Trough
Product
Comcode
Packaging
Colour
1A4
104141866
1/Pkg
White
Fibre
Accessories
LIUs
1A6 Horizontal Trough The 1A6 Fibre Optic Trough is a horizontal aluminium trough which is used to arrange fibre patch cords horizontally from one Interconnect Unit (LIU) to another in a multiunit fibre cross-connect, or from the LIU to the active electronics. The 1A6 is packaged with two mounting screws for wall mounted applications.
Physical Specifications PANELS
Height: 10.2cm
Figure 78
Width: 29.2cm
1A6 Horizontal
Depth: 10.2cm
Trough
Product
Comcode
Packaging
Colour
1A6
104141874
1/Pkg
White
141
PANELS
Fibre
Accessories
LIUs
Splice Adapter
Panels Contents Page
These kits adapt the 100A3 and 200A Interconnection Units (LIUs) for mechanical or fusion splice retention. The D-181706 holds 12 CSL splices while the D-181707 can hold 16 fusion splices. Splices can be ordered separately.
Figure 79 D-181706 Splice
PANELS
Adapter Kit
142
Product
Comcode
Length
Packaging
D-181706
105289656
12 CSL
1/Pkg
D-181707
105289664
16 Fusion
1/Pkg
PANELS
Fibre
600ALS Combination Shelf
Shelves
LazrSPEED™
Panels Contents Page
A rack-mountable, one unit high shelf, the 600ALS Combination Shelf houses 24 ST, 24 SC, or 48 LC terminations. This space saving shelf offers an easy solution for housing the connection of two cables or the interconnection of equipment. The 600ALS Combination Shelf is applicable for use in local area networks (LANs), premises distribution systems, and small count splice and termination applications. A detachable front panel allows easy access to the cable connectors. Figure 80 600ALS Combination Shelf
Physical Specifications Height: 4.4cm Width: 43.2cm Depth: 20.3cm
Product
Comcode
Connector Type
Packaging
600ALS/MM/LC-48
108565698
LC
1/Pkg
600ALS/MM/SC-24
108565706
SC
1/Pkg
600ALS/MM/ST-24
108565714
ST
1/Pkg
Lid Cover for 600A
108565433
–
1/Pkg
DTLS/600A-5
700008303
–
1/Pkg
1AMF1-6LG
700006281
–
1/Pkg
PANELS 143
PANELS
Fibre
600BLS Combination Shelf
Shelves
LazrSPEED
Panels Contents Page
The 600BLS Combination Shelf is an easy to install solution that meets your splicing and termination needs for up to 24 ST or SC connections and up to 48 LC connections. Its space saving slimline design features a front access, sliding shelf for easy access and installation. The lightweight, frame mounted shelf is suitable for your local area network, general premises distribution, and small count splice and termination applications. Each 600BLS is 1u and includes all adapters needed to terminate up to 48 fibres using LC connectors or 24 fibres
Figure 81
using SC or ST connectors. Its versatile design can accom-
600BLS Combination Shelf
modate up to 48 mechanical splices, 64 fusion splices, or 12 ribbon (mass fusion) splices using optional splice trays. The shelf contains a sliding tray with two 7.6cm (3 inch) storage drums and two openings with liquid tight fastens.
Physical Specifications Height: 4.4cm Width: 43.7cm
PANELS
Depth: 28.4cm
144
Product
Comcode
Connector Type
Packaging
600BLS/MM/LC-48
108565755
LC
1/Pkg
600BLS/MM/SC-24
108565763
SC
1/Pkg
600BLS/MM/ST-24
108565771
ST
1/Pkg
Lid Cover for 600B
108565458
–
1/Pkg
DTLS/600B-1.75
700008295
–
1/Pkg
PANELS
Fibre
LSTLS High Density Termination Shelf
Shelves
LazrSPEED
Panels Contents Page
The LSTLS High Density Termination Shelf features a fully modular design, increased protection and security, front and rear accessibility, and versatility as a stand alone unit. The shelves can be used to perform the functions most commonly required in the field, such as termination and interconnection. The LSTLS is a 4U (7 inch high) shelf designed for high fibre density locations, including equipment rooms and telecom closets. Figure 82
The shelf can terminate up to 144 LC connections, 72 SC
LSTLS High Density
connections or 72 STII+ connections. Built-in slack
Termination Shelf
management for each colour-coded LazrSPEED adapter strip facilitates fibre administration. The adapter bezel is detachable from the front, to provide easy access to the rear connector and fibre slack. The LSTLS is designed for mounting in a 19” rack for enterprise applications.
Product
Comcode
Connector Type
Packaging
LSTLS/MM/LC-144/7
108565631
LC
1/Pkg
LSTLS/MM/SC-072/7
108565649
SC
1/Pkg
LSTLS/MM/ST-072/7
108565656
ST
1/Pkg
PANELS 145
PANELS
Fibre
1100 Fibre Distribution Panel
Shelves
LazrSPEED
The 1100LS Fibre Distribution Panel is a high quality panel for terminating or inter-connecting fibres in a premise wiring system. The shallow panel depth makes the 1100LS ideal for wall mounted racks. Front access to the connectors behind the adapter strip is possible simply by removing the adapter bezel from the panel. The trim design and front access make the 1100LS panel an excellent solution for cramped and crowded telecommunication closets. The 1100LS was built to accommodate repeated line moves, additions and rearrangements. The kit includes adapter panels for 48 LC, 24 SC, or 24 ST terminations. The black housing design matches equivalent copper apparatus, and colour coded adapter panels simplify identification and administration. This can be mounted in a 19”rack designed for enterprise applications, or directly on a wall with an optional adapter kit. A convenient kit comes equipped with the distribution shelf, colour coded adapter strips with either LC, ST or SC adapters, and all mounting hardware.
Physical Specifications Height: 4.4cm Width: 48.3cm
PANELS
Depth: 12.1cm
146
Product
Comcode
Connector Type
Packaging
1100LS/MM/LC-48
108565557
LC
1/Pkg
1100LS/MM/SC-24
108565573
SC
1/Pkg
1100LS/MM/ST-24
108565581
ST
1/Pkg
Panels Contents Page
PANELS
Fibre
600A1 Shelf
Shelves
Combination Shelf
Panels Contents Page
The 600A1 One Unit Combination Shelf is a 19 inch rack mountable fibre distribution shelf for terminating and/or splicing indoor LGBC fibre optic cables. The assembly consists of a tray which contains rear corner and side slots for cable entry, steel brackets for rack flush/recessed mounting, fibre retainers for holding buffered fibres in place, and fibre storage drums that maintain a fibre bend radius of 3.81cm. The Front Connector Panels, 183U1 Cover, Splice
Figure 83
Organisers, Jumper Trough, Connectors and Couplings
600A1 Shelf, 24 ST-EW, 12 ST-EW, 24 ST &
should be ordered separately.
12 ST Panels, 183U1 Cover
Physical Specifications Height: 4.37cm Width: 43.18cm Depth: 20.32cm
Product
Comcode
Packaging
Colour
600A1
700007354
1/Pkg
Black
PANELS 147
PANELS
Fibre
600A1 Shelf Accessories
Shelves
Connector Panels The 600A1 Front Connector Panels are used with the 600A1 Combination Shelf for holding the connector couplings in place. They are available to accommodate 12 ST, 24 ST, 12 SC, 24 SC, 12 SC Duplex or 24 LC Duplex couplings. The Connector Panels are also available with the couplings already installed.
Physical Specifications Height: 3.7cm Width: 42.8cm
Product
Comcode
Ports
Packaging
12 ST Panel
700006620
12x ST cpl (Not incl.)
1/Pkg
12 SC Panel
700006588
12x SC cpl (Not incl.)
1/Pkg
24 ST Panel
700006646
24x ST cpl (Not incl.)
1/Pkg
24 SC Panel
700006604
24x SC cpl (Not incl.)
1/Pkg
12 SC Duplex Panel
700006562
12x SC Duplex cpl (Not incl.)
1/Pkg
12 LC Duplex Panel
700006414
12x LC Duplex cpl (Not incl.)
1/Pkg
12 ST-EW Panel
700006638
12x ST cpl (Included)
1/Pkg
12 SC-EW Panel
700006596
12x SC cpl (Included)
1/Pkg
24 ST-EW Panel
700006653
24x ST cpl (Included)
1/Pkg
24 SC-EW Panel
700006612
24x SC cpl (Included)
1/Pkg
12 SC-Duplex-EW Panel
700006570
12x SC Duplex cpl (Included)
1/Pkg
Fibre
600A1 Shelf Accessories
Shelves
PANELS
Cover The 183U1 Cover is a clear polycarbonate cover to be placed on top of the 600A1 Combination Shelf. It protects the fibres from damage and dust.
Physical Specifications Height: 42.8cm Width: 20.4cm
148
Product
Comcode
Packaging
Colour
183U1
700005028
1/Pkg
Transparent
Panels Contents Page
PANELS
Fibre
600A1 Shelf Accessories
Shelves
Trough
Panels Contents Page
The 1U-19 Trough is a 1 unit high aluminium trough which is mounted under the 600A1 Combination Shelf. The 1U-19 Trough is used to accommodate the slack from fibre jumper cables routed to/from the shelf.
Figure 84 IU-19 Trough
Physical Specifications Height: 5.6cm Width: 48.3cm Depth: 10.4cm
Product
Comcode
Packaging
Colour
1U-19
700008352
1/Pkg
Black
Fibre
600 Series Shelf Accessories
Shelves
Splice Organiser Trays PANELS
The 1AM1-12LG and 1AF1-16LG Splice Organisers are used both with the 600A1 and 600B2 Combination Shelves. The 1AM1-12LG is a Mechanical Splice Organiser, which holds up to 12 mechanical splices, while the 1AF1-16LG is a Fusion Splice Organiser, which holds up to 16 fusion splices. Both the 600A1 and the 600B2 Shelves can accommodate up to 24 mechanical splices or 32 fusion splices.
Product
Comcode
Description
Packaging
1AF1-16LG
105356562
Fusion Splice Organiser Tray
10/Pkg
1AM1-12LG
105356570
Mechanical Splice Organiser Tray
10/Pkg
149
PANELS
Fibre
600B2 Shelf
Shelves
Combination Shelf
Panels Contents Page
The 600B2 One Unit Combination Shelf is a 19 inch rack mountable fibre distribution shelf for terminating and/or splicing fibre optic cables. The assembly features a pullout aluminium tray for easy access to fibres and splices. The tray has two rear openings with liquid-tight cable glands, space for adding splice trays, and fibre storage drums that maintain a fibre bend radius 3.81cm. The front Connector Panels IU-17 trough, 184U1 Cover, Splice Organisers, Connectors and couplings should be ordered separately. The 600B2 Shelf uses the same splice
Figure 85
trays as the 600A1.
600B2 Shelf
The 600B2 can be used for indoor and dielectric outdoor (DNX and DDX cables) applications.
Physical Specifications Height: 4.37cm Width: 43.7cm
PANELS
Depth: 28.5cm
150
Product
Comcode
Packaging
Colour
600B2
700007321
1/Pkg
Black
PANELS
Fibre
600B2 Shelf Accessories
Shelves
Connector Panels
Panels Contents Page
The 600B2 Front Connector Panels are used with the 600B2 Combination Shelf for holding the connector Couplings in place. They are available to accommodate 12 ST, 24 ST, 12 SC, 24 SC, 12 SC Duplex or 24 LC Duplex couplings. The panels feature an integrated jumper trough. The panels are supplied stand alone or with couplings pre-loaded.
Physical Specifications Height: 3.7cm Width: 42.8cm
Product
Comcode
Couplings
Packaging
12ST1 Panel
700006497
12x ST cpl (Not incl.)
1/Pkg
12SC1 Panel
700006539
12x SC cpl (Not incl.)
1/Pkg
12SC1 DPLX Panel
700006521
12x SC DUPLEX (Not incl.)
1/Pkg
24ST1 Panel
700006455
24x ST cpl (Not incl.)
1/Pkg
24SC1 Panel
700006471
24x SC cpl (Not incl.)
1/Pkg
12LC1 DPLX Panel
700006406
12x LC DUPLEX (Not incl.)
1/Pkg
24LC1 DPLX Panel
700006398
24x LC DUPLEX (Not incl.)
1/Pkg
12ST1EW Panel
700006489
12x ST MM cpl (Included)
1/Pkg
12SC1EW Panel
700006505
12x SC cpl (Included)
1/Pkg
12SC1 DPLX-EW Panel
700006513
12x SC DUPLEX (Included)
1/Pkg
24ST1EW Panel
700006448
24x ST MM cpl (Included)
1/Pkg
24SC1EW Panel
700006463
24x SC cpl (Included)
1/Pkg
12ST1S-EW Panel
700006430
12x ST SM cpl (Included)
1/Pkg
24ST1S-EW Panel
700006422
24x ST SM cpl (Included)
1/Pkg
1U-17 Trough
700002348
N/A
1/Pkg
600B2 Shelf Accessories
PANELS
Fibre
Shelves
Cover
The 184U1 Cover is a clear polycarbonate cover to be placed on top of the 600B2 Combination Shelf. It protects the fibres from damage and dust.
Physical Specifications Height: 42.8cm Width: 20.4cm
Product
Comcode
Packaging
Colour
184U1
700005010
1/Pkg
Transparent
151
PANELS
Fibre
LGX Shelves
Shelves
LST1P-048ST Termination Shelf
Panels Contents Page
The LST1P-48ST/2.5 Shelf Terminating Unit is a 6.35cm (2.5 inch) high shelf that can be mounted in a 19 or 23 inch rack (19 inch mounting brackets ordered separately). The shelf comes equipped with two front access pivoting trays that will each accommodate 24 fibre ST-type terminations of LGBC buffered fibres. Each tray has two fibre slack storage drums which limit the fibre bend radius to 3.81cm. The trays have built-in coupling panels. However, ST connectors and couplings should be
Figure 86
ordered separately.
LST1P-048ST Termination Shelf
Physical Specifications Height: 6.3cm Width: 43.2cm
PANELS
Depth: 27.9cm
152
Product
Comcode
Terminations
Packaging
LST1P-48ST
700007263
48x ST cpl
1/Pkg
19 inch Bracket
108527441
N/A
1/Pkg
PANELS
Fibre
LGX Shelves
Shelves
LST1U-072/7 Termination Shelf
Panels Contents Page
The LST1U-072/7 Termination Shelf is used for terminating up to 72 fibres from indoor Lightguide Building Cables (LGBC) or outdoor Outside Plant (OSP) cables. The shelf comes with a hinged, smoked transparent, plastic front door and white hinged polycarbonate rear door for both front and rear access. Also included are: universal brackets for mounting the shelf in 19 and 23 inch racks or directly onto the wall; cable clamp brackets for securing LGBC cables and 12A clamps for OSP cable; and blank labels
Figure 87
attached to the inside of the front door for fibre identification.
LST1U-072/7 Termination Shelf
Inside the cabinet, there is a hinged panel mounting bracket which can accept up to twelve 6-way coupling panels. The coupling panels, couplings and connectors should be ordered separately. OSP cable terminating hardware such
Physical Specifications
as the 12A Cable Clamp, Buffer Tubing Kit, B-Sealant and
Height: 17.8cm
Blocking Kits should also be ordered separately.
Width: 43.2cm Depth: 27.9cm
Product
Comcode
Terminations
Packaging
LST1U-072/7
700007289
72
1/Pkg
LGX Shelves
Shelves
LST1F-072/7 Termination Shelf
The LST1F-072/7 Termination Shelf is the same
PANELS
as the LST1U-072/7 except the entire contents of the shelf is mounted on a slide out panel for easy front access.
Physical Specifications Height: 17.8cm
Figure 88
Width: 43.2cm
LST1F-072/7
Depth: 27.9cm
Termination Shelf
Product
Comcode
Terminations
Packaging
LST1F-072/7
700007271
72
1/Pkg
153
PANELS
Fibre
LGX Shelves
Shelves
LSS1U-072/5 Splice Shelf
Panels Contents Page
The LSS1U-072/5 Splice Shelf is generally used in conjunction with an LST1U-072/7 Terminating Shelf or in splice-only applications to house mechanical or fusion splices. The shelf comes with hinged white polycarbonate front and rear doors equipped with knockouts for optional lock mechanisms. Also included are: universal brackets for mounting the shelf in 19 and 23 inch racks or directly onto the wall; cable clamp brackets for the securing of LGBC cables and 12A clamps for OSP cable; three splice tray housings for accepting the splice trays; and blank labels attached to the inside
Figure 89
of the front door for fibre/splice identification.
LSS1U-072/5 Splice Shelf
OSP cable terminating hardware such as the 12A Cable Clamp, B-Sealant and Blocking Kits should be ordered separately. Splice Organiser Trays and Pigtails should also be ordered separately.
Physical Specifications Height: 12.7cm Width: 43.2cm
PANELS
Depth: 27.9cm
154
Product
Comcode
Terminations
Packaging
LSS1U-072/5
700007230
72
1/Pkg
PANELS
Fibre
LGX Shelves
Shelves
LSC2U-024/5 Combination Shelf
Panels Contents Page
The LSC2U-024/5 Combination Shelf is used for a combination of splicing and terminating up to 24 fibres from indoor Lightguide Building Cables (LGBC) or up to four outdoor Outside Plant (OSP) cables. The shelf is designed as a termination only or splicing and termination of pigtails. The shelf comes with a hinged, smoked transparent, plastic front door and white hinged polycarbonate rear door for both front and rear access. Also included are: universal brackets for mounting the shelf in 19 and 23 inch racks or directly onto the wall; cable clamp brackets for securing of
Figure 90
LGBC cables and 12A clamps for OSP cable; and blank labels
LSC2U-024/5
attached to the inside of the front door for fibre identification.
Combination Shelf
Inside the cabinet, there is a panel mounting bracket which can accept up to four 6-way coupling panels. Under the termination area, there is provision for one LT1A-type splice tray. The coupling panels, couplings, connectors, and splice trays should be ordered separately. OSP cable terminating hardware such as the 12A Cable Clamp, Buffer Tubing Kit, B-Sealant and Blocking Kits should also be ordered separately.
Physical Specifications Height: 12.7cm Width: 43.2cm Depth: 27.9cm
Comcode
Terminations
Packaging
LSC2U-024/5
700007255
24
1/Pkg
PANELS
Product
155
Panels p101-p156.qxd 22/08/2001 11:34 Page 156
PANELS
Fibre
LGX Accessories
Shelves
Panels
Panels Contents Page
The LGX Coupling Panels are mounted in LGX shelves and used to accept ST, SC, Duplex SC, Duplex LC or FDDI Couplings. The ST and SC Coupling Panels can accept up to 6 couplings, the Duplex SC panel accepts up to three couplings, the Duplex LC panel accepts up to six couplings, and the FDDI panel accepts up to 6 FDDI couplings (but requires the space of two of the other Coupling Panels).
Figure 91 1000ST, 1000SC1-DPLX and 1000SC Panels
Physical Specifications Height: 1000: 2.85cm; 2000: 5.7cm Width: 12.9cm
156
Product
Comcode
Ports
Packaging
1000ST
700011109
6x ST cpl
12/Pkg
1000SC1-DPLX
700010952
3x Dpx SC cpl
1/Pkg
1000LC1-DPLX
700011414
3x Dpx LC cpl
1/Pkg
Outlets Chapter
4
157
Outlets Contents
Click Here Main Menu
Copper HDMs GigaSPEED® MGS300 Series 159 Category 5 MPS100E Series
161
Icons & M-Series Cap
163
Category 3 - M1 Series
165
FACEPLATES US Standard
166
UK/Ireland Standard
168
French Standard
169
Italian Standard
170
Scandinavian Standard
171
Benelux/German Standard
173
Universal Standard
174
Fibre FURNITURE Modular Faceplate
179
FIBRE Surface Mounted
180
Multimedia MULTIMEDIA Surface Mounted
158
181
OUTLETS
Copper
GigaSPEED® MGS300 Series
HDMs
MGS300
Outlets Contents Page
The versatile MGS300 Series outlets work together with the GigaSPEED cables, cords and panels to provide performance Listed
beyond proposed Category 6 standards. A new feature of the MGS300 is a universal coloured wiring label that eliminates the need for separate Comcodes for 568A/B wiring schemes. Design features include: - Superb electrical performance when mated with low variability GigaSPEED cords. Snaps into any M-series modular faceplate, frame, or surface-mounted box. - Can be mounted either at 90 degrees (straight) or at 45 degrees (angled). Angled feature eliminates the need
Figure 92 MGS300 Series High Density Modules
for special faceplates. - Multi-coloured identification labels assure fast, accurate installation. - Low-profile wire cap protects against contamination and secure connections. - Improved pair splitters and wider channel for enhanced conductor placement and termination. - They can accommodate both TS68A and B wiring. The 8 position/8 conductor MGS300 snap into any M-series modular faceplate, frame, surface mount box or M1000 MultiMAX Panel. Once inserted, the outlets lock into place and can be easily released using a wire insertion cap. The Installation D-Impact Tool or wire cap can be used to terminate the wire conductor. The MGS300 forms an integral part of the solution product portfolio. The solution is guaranteed to meet the Category 6/Class E Channel Specifications proposed for ISO/IEC and TIA, even under the worst case channel configuration (100 metres, four connections). Note that in all cases the channel
OUTLETS
specifications meet or exceed the Category 5e Standard and proposed Category 6 Standard.
Physical Specifications Width: 2cm Length: 2cm Depth: 3.1cm Plastic: High-impact, flame retardant, UL-rated 94V-0 thermoplastic Outlet Wires: Copper alloy, 50 micro-inch lubricated gold plating over 100 micro-inch nickel underplate Connector: Copper alloy, 100 micro-inch bright solder over 100 micro-inch nickel underplate Insertion Life: > 750 Min. Contact Force: 100 g using FCC - approved modulas plug Min. Plug Retention Force: 133 N Operating Temperature Range: -40 to 66ºC
159
OUTLETS
Copper
OUTLETS
Product
160
GigaSPEED MGS300 Series
Comcode
HDMs
MGS300 (contd)
Packaging
Colour
MGS300BH-003
108601790
1/Pkg
Black
MGS300BH-112
108601816
1/Pkg
Orange
MGS300BH-123
108601814
1/Pkg
Yellow
MGS300BH-226
108601857
1/Pkg
Green
MGS300BH-246
108601873
1/Pkg
Ivory
MGS300BH-262
108601881
1/Pkg
White
MGS300BH-270
108601899
1/Pkg
Grey
MGS300BH-317
108601907
1/Pkg
Red
MGS300BH-318
108601915
1/Pkg
Blue
MGS300BH-361
108601923
1/Pkg
Violet
MGS300BH-215
108601840
1/Pkg
Cream
Outlets Contents Page
OUTLETS
Copper
Category 5 MPS100E Series
HDMs
MPS100E High Density Modules
Outlets Contents Page
The MPS100E High Density Module (HDM) is a Modular RJ45 to insulation displacement connector (IDC). It is Listed
typically installed in the faceplate at the work location and provides termination for the horizontal 4-pair cable at the IDC end, and workstation cord insertion at the RJ45 end. It is designed for high speed data and video applications. The insulation displacement connectors accept 22 and 24AWG insulated wire. High-tooth pair splitters have been enhanced to separate very tightly twisted Power Sum cable
Figure 93 MPS100E High Density Modules
pairs to maintain the twist up to the connection. A DImpact Tool can be used to terminate conductors. The Information Outlet is shipped with a space saving wire flat cap, that should be used to provide protection from contamination and to secure the connections. Multi-colour labels with straight forward wire placement sequence mark wire terminals, assuring fast, accurate installation. Snap on Icons identify the outlet as an MPSE product either computer or a data connection. The MPS100E information outlets are designed to snap into any M-Series faceplate, frame, or surface-mount box. As an added feature, the outlet can mount either at 90 degrees (straight) or 45 degrees (angled) into these faceplates, frames or boxes: this allows angled mounting of the outlet without having to use special faceplates. Once inserted in either the straight or angled mounting, the outlets lock into place and can only be released using the dual-purpose wire insertion cap.
OUTLETS
These 8-position/8-conductor jacks meet Power Sum NEXT requirements and is part of the Avaya Power Sum Solution that meets channel Category 5e transmission requirements. The MPS100E Series is compatible with 10 Mb/s IEEE 802.3 10BASE-T applications. Fully supports 100 Mb/s TP-PMD at 100m (328ft) over UTP per ANSI X3T9.5, and is also compatible with 16 Mb/s IEEE 802.5 Token Ring applications. MPS100E outlets meet or exceed the Category 5 and Category 5e requirements in ISO/IEC 11801, CENELEC EN 50173, and EIA/TIA 568A.
161
OUTLETS
Copper
Category 5 MPS100E Series
HDMs
MPS100E High Density Modules (contd)
Physical Specifications Length: 2.0cm Width: 2.0cm Depth: 3.1cm Plastic: High-impact, flame retardant, UL-rated 94V-0 thermoplastic Jack Wires: Copper alloy, 1.27 µm lubricated gold plating over 2.54 µm nickel underplate Connector: Insulation displacement connectors (IDC) accept 22 & 24-AWG wire Insertion Life: > 750 Min. Contact Force: 100 g Min. Plug Retention Force: 133 N Operating Temperature Range: -40 to 66ºC
Electrical Specifications EIA/TIA Category: 5e Min. Insulation Resistance: 500 mΩ Min. Dielectric Withstand Voltage (Contact to contact @ 60 Hz): 1000 VAC RMS Min. Dielectric Withstand Voltage (To exposed conductive surface @ 60 Hz): 1500 VAC RMS Max. Contact Resistance: 20 mΩ
OUTLETS
Current Rating @ 20ºC: 1.5 A
162
Product
Comcode
Wiring Scheme
Packaging
Colour
MPS100E - 003
108232695
T568B
1/Pkg
Black
MPS100E - 112
108232703
T568B
1/Pkg
Orange
MPS100E - 123
108232711
T568B
1/Pkg
Yellow
MPS100E - 226
108232729
T568B
1/Pkg
Green
MPS100E - 246
108232737
T568B
1/Pkg
Ivory
MPS100E - 262
108232745
T568B
1/Pkg
White
MPS100E - 270
108232752
T568B
1/Pkg
Grey
MPS100E - 317
108232760
T568B
1/Pkg
Red
MPS100E - 318
108232778
T568B
1/Pkg
Blue
MPS100E - 361
108337726
T568B
1/Pkg
Violet
Outlets Contents Page
OUTLETS
Copper
Icons & M-Series Cap
HDMs
MPS100E & MGS300
Outlets Contents Page
Icons for the MGS300 and the MPS100E Information Outlets are available in nine colours. These icons come in strips of three. The MPS100E icons are the following: one with a computer symbol, one with “DATA” and one with “MPSE”. The MGS300 icons are available with the following written on the front: one with a computer symbol, one with “DATA”, and one with “GS”. Also available are icons for voice applications which display the word “VOICE”. These icons are snapped into the top of the MGS300 or the MPS100E when flush mounted and on the top angled surface when mounted at an angle. The icons are packaged 100 to a bag with 5 bags in a box.
ICONS FOR MGS300 Product
Comcode
Description
Packaging
Colour
M61A-003
108065657
Computer Icon, DATA, GS
500/Pkg
Black
M61A-112
108065673
Computer Icon, DATA, GS
500/Pkg
Orange
M61A-123
108065707
Computer Icon, DATA, GS
500/Pkg
Yellow
M61A-226
108065731
Computer Icon, DATA, GS
500/Pkg
Green
M61A-246
108065756
Computer Icon, DATA, GS
500/Pkg
Ivory
M61A-262
108065780
Computer Icon, DATA, GS
500/Pkg
White
M61A-270
108065806
Computer Icon, DATA, GS
500/Pkg
Grey
M61A-317
108065814
Computer Icon, DATA, GS
500/Pkg
Red
M61A-318
108065822
Computer Icon, DATA, GS
500/Pkg
Blue
ICONS FOR MPS100E & VOICE ICONS Comcode
Description
Packaging
Colour
M61H-003
108373515
Computer Icon, MPSE, DATA
1/Pkg
Black
M61H-112
108373523
Computer Icon, MPSE, DATA
1/Pkg
Orange
M61H-123
108373531
Computer Icon, MPSE, DATA
1/Pkg
Yellow
M61H-226
108373549
Computer Icon, MPSE, DATA
1/Pkg
Green
M61H-246
108373564
Computer Icon, MPSE, DATA
1/Pkg
Ivory
M61H-262
108373572
Computer Icon, MPSE, DATA
1/Pkg
White
M61H-270
108373580
Computer Icon, MPSE, DATA
1/Pkg
Grey
M61H-317
108373598
Computer Icon, MPSE, DATA
1/Pkg
Red
M61H-318
108373606
Computer Icon, MPSE, DATA
1/Pkg
Blue
M61H-361
108373614
Computer Icon, MPSE, DATA
1/Pkg
Violet
OUTLETS
Product
163
OUTLETS
Copper
Icons & M-Series Cap
HDMs
MPS100E & MGS300 (cond)
Outlets Contents Page
ICONS FOR MPS100E & VOICE ICONS (contd) Product
Comcode
Description
Packaging
Colour
M61F-226
108066267
VOICE Icon Connector
500/Pkg
Green
M61F-246
106066275
VOICE Icon Connector
500/Pkg
Ivory
M61F-262
108066283
VOICE Icon Connector
500/Pkg
White
M61F-270
108066291
VOICE Icon Connector
500/Pkg
Grey
M61F-317
108066309
VOICE Icon Connector
500/Pkg
Red
M61F-318
108066317
VOICE Icon Connector
500/Pkg
Blue 100 per bag, 5 bags per box
OUTLETS
M-SERIES WIRE TERMINATION CAP
164
Product
Comcode
Packaging
Colour
CAP M-series HDM
108180894
100/Pkg
White
OUTLETS
Copper
Category 3 - M1 Series
HDMs
M1 High Density Modules
Outlets Contents Page
The M1 High Density Module (HDM) is a Modular RJ45 to Insulation Displacement Connector (IDC). It is typically installed in the faceplate at the work location and provides termination for the horizontal 4-pair cable at the IDC end, and workstation cord insertion at the RJ45 end. The M1 was designed and patented by Avaya Labs. The insulation displacement connectors of the M1 can accept 0.643 mm - 0.511 mm diameter (22 - 24 AWG) solid or stranded insulated copper conductors. Each M1 comes with two modular insertion caps which can be used to seat
Figure 94
0.511 mm (24AWG) solid conductors into the IDC. Other
M1 High Density Modules
conductors should be seated with the 8762D Impact Tool. The caps remain clipped onto the M1 after termination to provide added protection from contamination as well as to secure the connection. The M1 meets or exceeds attenuation and crosstalk Category 3 requirements for connecting hardware as specified in ISO/IEC IS11801, CENELEC EN50173, and Listed
EIA/TIA 568A. The M1 is UL listed.
Physical Specifications Length: 2.0cm Width: 2.0cm Depth: 3.1cm Plastic: High-impact, flame retardant, UL-rated 94V-0 thermoplastic Jack Wires: Copper alloy, 1.27 µm lubricated gold plating over 2.54 µm nickel underplate Connector: Insulation displacement connectors (IDC) accept 22 & 24-AWG wire Insertion Life: > 750
Min. Contact Force: 100 g
Min. Plug Retention Force: 133 N
Operating Temperature Range: -40 to 66ºC
OUTLETS
Electrical Specifications EIA/TIA Category: 3
Min. Insulation Resistance: 500 MΩ
Min. Dielectric Withstand Voltage (Contact to contact @ 60 Hz): 1000 VAC RMS Min. Dielectric Withstand Voltage (To exposed conductive surface @ 60 Hz): 1500 VAC RMS Max. Contact Resistance: 20 mΩ
Product
Comcode
Current Rating @ 20ºC: 1.5 A
Packaging
Colour
M1BH-003
107321697
1/Pkg
Black
M1BH-246
107321721
1/Pkg
Ivory
M1BH-262
107321739
1/Pkg
White
165
OUTLETS
Copper
US Standard
Faceplates
Modular Faceplates
Outlets Contents Page
The M12L, M13L, and M14L are flush-mounted US standard M-Series Modular Faceplates designed for use with two, three, or four M-Series High Density Modules (M1, MPS100E or MGS300). The M12L is duplex, the M13L is triplex, and the M14L is quadplex. The faceplate outlet openings are numbered on both sides for installation and maintenance identification. Optional M20AP Dust Covers/Blanks may be used to cover any unused outlets or outlet openings. Standard package includes the modular faceplate and Figure 95
two mounting screws for installation in an American (US)
M12L, M13L, and
standard electrical outlet box.
M14L Faceplates
Physical Specifications Width: 7.11cm Length: 11.7cm Depth: 0.76cm
OUTLETS
Plastic: High-impact, flame retardant, UL-rated 94V-0 thermoplastic
166
Product
Comcode
Ports
Packaging
Colour
M12L-246
108168477
2x HDMs
1/Pkg
Ivory
M13L-246
108168519
3x HDMs
1/Pkg
Ivory
M14L-246
108168550
4x HDMs
1/Pkg
Ivory
OUTLETS
Copper
US Standard
Faceplates
Dust Cover
Outlets Contents Page
The M20AP are dual-purpose blank Dust Covers designed for use with the modular outlets (M1, MPS100E or MGS300) and modular faceplate kits (except for the Shuttered clips and Benelux faceplates). When the M20AP is used as a Dust Cover, it is inserted over the outlet opening and will protect the jack wires from dust. The M20AP can also be used with modular faceplates as a blank cover for empty jack openings which are not populated with modular outlets. Figure 96 M20AP Dust Covers
Physical Specifications Width: 1.52cm Length: 1.78cm Depth: 0.51cm Plastic: High-impact, flame retardant, UL-rated 94V-0 thermoplastic
Product
Comcode
Packaging
Colour
M20AP-003
107065583
500/Pkg
Black
M20AP-246
107067860
500/Pkg
Ivory
M20AP-262
107067928
500/Pkg
White
OUTLETS 167
OUTLETS
Copper
UK/Ireland Standard
Faceplates
Faceplates and Clips
Outlets Contents Page
The range of UK/Ireland Standard Information Outlets consist of the M12D & M14D Faceplates, and the LF80 & LF00 Clips. The M12D is a flush-mounted, duplex, 2-gang UK/Ireland standard faceplate designed to accept two LF80 or LF00 Clips. The M14D is a flush-mounted, quadplex, 4-gang UK/Ireland standard faceplate designed to accept four LF80 or LF00 Clips (or any combination of the two). The standard package for each includes the faceplate plus two mounting screws for installation in a UK standard
Figure 97
35mm (for Mark V) or 32mm (for Mark VI) electrical box.
Faceplate Clip UR Stand
The LF80 Clips (Mark V and VI) fit into the M12D and M14D and accept one High Density Module (M1, MPS100E or MGS300). The Mark V is equipped with a spring-loaded shutter to protect the HDM from dust. It can be cabled through the faceplate and fits into minimum 35mm depth boxes. There is a provision for port labelling. The Mark VI is angled and has a unique self-cleaning shutter design. It can be cabled through the faceplate and fits into minimum 32mm depth boxes. The LF00 Clip is a blank snap-in clip used in vacant slots of the M12D or M14D Faceplate.
Physical Specifications Faceplate Height: 8.50cm Faceplate Width: M12D: 8.50cm; M14D: 14.6cm Faceplate Depth: 0.90cm Clip Height: 3.8cm Clip Width: 2.5cm
OUTLETS
Clip Depth: Mark V & LF00: 1.4 cm; Mark VI: 2cm
168
Product
Comcode
Ports
Packaging
Colour
M12D
407900471
2x LF80/LF00
1/Pkg
White
M14D
407900463
4x LF80/LF00
1/Pkg
White
LF80 Mark V clip
407900422
1x HDM
1/Pkg
White
LF80 Mark VI clip
407901909
1x HDM
1/Pkg
White
LF00
407900448
N/A
1/Pkg
White
OUTLETS
Copper
French Standard
Faceplates
LF81 Clip
Outlets Contents Page
The LF81 Clip accepts one High Density Module (M1, MPS100E or MGS300) and is equipped with a spring-loaded shutter to protect the HDM from dust. It is designed specifically for the French market and fits in a standard 50 mm x 25 mm moulded Le grand faceplate. The clip (while inserted in the faceplate) can be mounted into a French standard electrical box with a minimum depth of 32 mm. There is a provision for port labelling.
Physical Specifications Height: 5.00cm Width: 2.50cm Depth: 1.40cm
Product
Comcode
Ports
Packaging
Colour
LF81
108230632
1x HDM
1/Pkg
White
Copper
French Standard
Faceplates
M12LG Clip The M12LG Clip accepts one High Density Module (M1, MPS100E or MGS300) and is equipped with a spring-loaded shutter to protect the HDM from dust. It is designed specifically for the French market and fits in the Le grand Mosaic faceplate. The clip (inserted in the faceplate) can be mounted into a French standard electrical
OUTLETS
box with a minimum depth of 32 mm. There is a provision for port labelling.
Physical Specifications Figure 98
Height: 4.50cm
M12LG Clip
Width: 4.50cm Depth: 2.50cm
Product
Comcode
Ports
Packaging
Colour
M12LG-262
107347080
1x HDM
1/Pkg
White
169
OUTLETS
Copper
French Standard
Faceplates
M12 Dual Clip
Outlets Contents Page
The M12 Dual Clip accepts two High Density Modules (M1, MPS100E or MGS300). It is designed specifically for the French market and fits in the Le grand Mosaic faceplate. The clip (inserted in the faceplate) can be mounted into a French standard electrical box with a minimum depth of 32 mm. There is a provision for port labelling.
Physical Specifications Height: 4.50cm Figure 99
Width: 4.50cm
M12 Dual Clip
Depth: 2.50cm
Product
Comcode
Ports
Packaging
Colour
M12-262
107991143
2x HDM’s
1/Pkg
White
Copper
Italian Standard
Faceplates
Click-in Clips The LF82 and LF83 Clips each accept one High Density Module (M1, MPS100E or MGS300) and are designed specifically for the Italian market. The LF82 Clip is black in colour while the LF83 is ivory. The LF82 and LF83 Clips fit in a standard Italian faceplate which can then be mounted onto an Italian standard electrical box with a minimum
OUTLETS
depth of 32 mm. There is a provision for port labelling.
Physical Specifications
Figure 100 LF82IT and
Height: 4.39cm
LF83IT Clips
Width: 2.48cm Depth: 2.50cm
Product
170
Comcode
Ports
Packaging
Colour
LF82IT
106961311
1x HDM
1/Pkg
Black
LF83IT
106961329
1x HDM
1/Pkg
Ivory
OUTLETS
Copper
Scandinavian Standard
Faceplates
MFUGAS Faceplate
Outlets Contents Page
The MFUGAS Danish Faceplate is a dual flushmount faceplate which mounts in a FUGA box (or equivalent) and accepts two High Density Modules (M1, MPS100E or MGS300). It consists of the cover and baseplate.
Physical Specifications Height: 71mm Width: 45mm
Figure 101
Depth: 8.5mm
MFUGA Faceplate
Product
Comcode
Ports
Packaging
Colour
MFUGA-262
106790140
2x HDM’s
1/Pkg
White
MFUGA-290
106790157
2x HDM’s
1/Pkg
Grey
Copper
Scandinavian Standard
Faceplates
MFUGAS Faceplate The MFUGAS Danish Faceplate is a single flushmount faceplate which mounts in a FUGA box (or equivalent) and accepts one High Density Module (M1, MPS100E or MGS300).
OUTLETS
Physical Specifications Height: 45mm Width: 45mm
Figure 102
Depth: 8.5mm
MFUGAS Faceplate
Product
Comcode
Ports
Packaging
Colour
MFUGAS-262
106969066
1x HDM
1/Pkg
White
MFUGAS-290
106973480
1x HDM
1/Pkg
Grey
171
OUTLETS
Copper
Scandinavian Standard
Faceplates
MFUGAIS Faceplate
Outlets Contents Page
The MFUGAIS Danish Faceplate is a single angled faceplate which mounts in a FUGA box (or equivalent) and accepts one High Density Module (M1, MPS100E or MGS300). It consists of the cover and baseplate.
Physical Specifications Height: 71mm Width: 45mm
Figure 103
Depth: 30.5mm
MFUGAIS Faceplate
Product
Comcode
Ports
Packaging
Colour
MFUGAIS-262
106973472
1x HDM’s
1/Pkg
White
MFUGAIS-290
106969058
1x HDM’s
1/Pkg
Grey
Copper
Scandinavian Standard
Faceplates
SENSIQ-EPUS Faceplate The M12E EPUS Faceplate is used in the SENSIQ 85x85 and EPUS 85x85 switch and socket outlet systems. It should be mounted in a standard IEC box and frame. It is suited for use in Eastern and Northern European markets
OUTLETS
(Denmark excluded).
Physical Specifications Height: 72mm
172
Figure 104
Width: 72mm
M12E SENSIQ-EPUS
Depth: 9mm
Faceplate
Product
Comcode
Ports
Packaging
Colour
M12E
107818338
2x HDM’s
1/Pkg
White
OUTLETS
Copper
Benelux/German Standard
Faceplates
Faceplates and Accessories
Outlets Contents Page
The range of Benelux/German Standard Information Outlets include the M18930 Surface Outlet, M18932 Flushmount Centreplate, M02714 Coverplate and M81 Dust Covers. The M18930 Outlet is a surface-mounted duplex M-Series Modular Information Outlet designed for use with two MSeries High Density Modules (M1, MPS100E or MGS300). The outlet openings have provision for label identification. Figure 105
The M18932 Centreplate is a flush-mounted centreplate
M18932 Centreplate,
which is also designed to accept two M-Series HDM’s. The
M02714 Coverplate,
M18932 mounts in a German/Benelux standard electrical
M18930 Faceplate and M81 Dust Covers
box with centreplate mounting dimensions of 60 mm centre to centre and with a minimum depth of 32 mm. The outlet openings have provision for label identification. The M02714 Flushmount Coverplate is used with the M18932 centreplate to provide a frame around the mounting screws of the centreplate. The M81 are dust covers designed for use with the M18930 and M18932 Faceplates. The M81 is used in empty jack openings which are not populated with High Density Modules.
Physical Specifications M18930: Height:
8.0cm
M18932: Height:
5.0cm
Width:
6.5cm
Width:
5.0cm
Depth:
3.5cm
Depth:
0.73cm
8.0cm
Height:
1.8cm
Width:
8.0cm
M81:
Width:
2.6cm
Depth:
0.55cm
Depth:
1.3cm
Product
Comcode
Ports
Packaging
Colour
M18930-246
999901618
2x HDM's
1/Pkg
Ivory
M18930-262
999901620
2x HDM's
1/Pkg
White
M18932-246
999901617
2x HDM's
1/Pkg
Ivory
M18932-262
999901619
2x HDM's
1/Pkg
White
M02714-246
999901621
M18932
1/Pkg
Ivory
M02714-262
999901622
M18932
1/Pkg
White
M81-246
106837222
N/A
1/Pkg
Ivory
M81-262
106837230
N/A
1/Pkg
White
OUTLETS
M02714: Height:
173
OUTLETS
Copper
Universal Standard
Faceplates
Surface Mounted Boxes
Outlets Contents Page
The Universal Standard Surface Mounted Boxes are designed to accept 1, 2, 4, 6, or 12 M-Series High Density Modules (M1, MPS100E or MGS300). The product family consists of the M101SMB, M102SMB, M104SMB, M106SMB, and M112SMB. These boxes can be mounted on any flat surface using the screws or double-sided adhesive tape provided. Optional magnets can be ordered for use with the M104SMB (1 required), M106SMB (4 required) and M112SMB (4 required). M20AP Dust Covers are provided
Figure 106
with the M104SMB (3), M106SMB (3), and M112SMB (6).
M101SMB, M102SMB, M104SMB and M112SMB Outlets
Physical Specifications M101:
M104:
M112:
Height:
3.0cm
Height:
5.3cm
Width:
6.1cm
Width:
6.1cm
Depth:
3.3cm
Depth:
3.3cm
Height:
7.4cm
Height:
12.2cm
Width:
10.2cm
Width:
13.9cm
Depth:
3.3cm
Depth:
3.3cm
Height:
12.2cm
Width:
22.9cm
Depth:
3.3cm
M102:
M106:
OUTLETS
Plastic: High-impact, flame retardant, UL-rated 94V-0 thermoplastic
174
Product
Comcode
Ports
Packaging
Colour
M101SMB-246
107984007
1x HDM
1/Pkg
Ivory
M101SMB-262
107984015
1x HDM
1/Pkg
White
M102SMB-246
107984049
2x HDMs
1/Pkg
Ivory
M102SMB-262
107984056
2x HDMs
1/Pkg
White
M104SMB-246
107952442
4x HDMs
1/Pkg
Ivory
M104SMB-262
107952459
4x HDMs
1/Pkg
White
M106SMB-246
107431546
6x HDMs
1/Pkg
Ivory
M106SMB-262
107431538
6x HDMs
1/Pkg
White
M112SMB-246
106658149
12x HDMs
1/Pkg
Ivory
M112SMB-262
106658156
12x HDMs
1/Pkg
White
OUTLETS
Copper
Universal Standard
Faceplates
Magnets
Outlets Contents Page
The D-180880 Mounting Magnets are designed to mount the M104SMB, M106SMB, and M112SMB surface-mount outlets/outlet boxes to any steel surface such as office furniture or modular walls. One magnet is required for the M104SMB, and four for the M106SMB & M112SMB. The magnets are inserted into the base of the outlet and secured by the outlet cover.
Physical Specifications Figure 107
Height: 8mm
D-180880 Magnets
Width: 25mm Depth: 20mm
Product
Comcode
Packaging
D-180880
103184156
4/Pkg
3345A
106928765
2/Pkg
Copper
Universal Standard
Faceplates
MCAN Faceplate The MCAN Faceplate is a dual flushmount faceplate which mounts on a CAN/Clickline electrical box (or equivalent) and accepts two High Density Modules (M1, MPS100E or MGS300).
OUTLETS
The MCAN Kit consists of a faceplate and an adapter frame for mounting in a standard IEC (c/c 60mm) electrical box. The MCAN Adapter Frame provides secure and tidy mounting for the MCAN Faceplate in a standard IEC wall box (C/C 60mm).
Figure 108 MCAN Adapter Frame
Physical Specifications Height: 85mm Width: 85mm Depth: 8.8mm
Product
Comcode
Ports
Packaging
Colour
MCAN-DL-262
106790165
2x HDM’s
1/Pkg
White
175
OUTLETS
Copper
Universal Standard
Faceplates
MTDL80
Outlets Contents Page
The MTDL80 Universal Faceplate is a dual semi-surface mounted faceplate which can be surface or flush-mounted on a standard IEC box (C/C 60mm) and also mounted on any type of electrical trunking. It accepts two High Density Modules (M1, MPS100E or MGS300). It comes complete (without HDM’s) and ready to mount.
Figure 109 MTDL80 Faceplate
Physical Specifications Height: 80mm Width: 80mm
OUTLETS
Depth: 36mm
176
Product
Comcode
Ports
Packaging
Colour
MTDL80-262
106790132
2x HDM’s
1/Pkg
White
OUTLETS
Copper
Universal Standard
Faceplates
Mounting Collar
Outlets Contents Page
The M30MC Universal Mounting Collar is designed to flush mount one M-Series Modular High Density Module (M1, MPS100E or MGS300) onto any flat surface with a pre-cut rectangular opening. See Physical Specifications for required dimensions of opening.
Figure 110 M30MC Mounting Collar
Physical Specifications Collar Support Thickness: 0.635 - 3.175 mm Opening Height: 19.94mm Opening Width: 19.38 ± 0.08mm Mounting Collar Height: 25.4mm Mounting Collar Length: 25.4mm Mounting Collar Depth: 11.7mm Plastic: High-impact, flame retardant, UL-rated 94V-0 thermoplastic
Product
Comcode
Packaging
Colour
M30MC-246
106664139
100/Pkg
Ivory
M30MC-262
106664147
100/Pkg
White
M30MC-003
106664154
100/Pkg
Black
OUTLETS 177
OUTLETS
Copper
Universal Standard
Faceplates
Zone Wiring Boxes
Outlets Contents Page
Zone Wiring Boxes (ZWBs) provide flexible interconnection points for horizontal wiring applications. They enable open office spaces to be reconfigured frequently without the expense of disturbing horizontal cable runs. The Zone Wiring Box (ZWB) connects to the telecommunications closet via 25-pair cable or six 4-pair cables. This compact space saving wiring box is available in two models: 110 Connector to Modular Jack and 110 Connector to 110 Connector. Figure 111
Avaya has designed these ZWBs to be easily installed and
ZWBA1 Zone
administered. Screws and double sided tape provide for easy
Wiring Box
wall mounting. Upper and lower housings snap together for clean closure. Administration is simplified with easy to read labelling cards. M-series modules can be colour coded and Snap-On Listed
coloured icons display voice or data applications.
Physical Specifications Width: 5.5cm Length: 19cm Depth: 3.9cm Wire Ranges: 22-26 AWG Terminations: >200
Electrical Specifications DC Resistance: < 0.1 Ω
OUTLETS
DC Resistance Unbalance: < 5mΩ Tip/Ring
178
Product
Comcode
Ports
Packaging
Colour
ZWBA1-003
107984338
110 IDC to Modular Jack
1/Pkg
Black
ZWBA1-246
107984080
110 IDC to Modular Jack
1/Pkg
Ivory
ZWBA1-262
107984353
110 IDC to Modular Jack
1/Pkg
White
ZWBA1-270
107984361
110 IDC to Modular Jack
1/Pkg
Grey
ZWBC1-246
107984346
110 IDC to 110 IDC
1/Pkg
Ivory
ZWBC1-262
107984098
110 IDC to 110 IDC
1/Pkg
White
ZWBC1-270
107984106
110 IDC to 110 IDC
1/Pkg
Grey
OUTLETS
Fibre
Modular Faceplate
Furniture
Furniture Faceplate
Outlets Contents Page
The M13CLS Modular Furniture Triplex Outlet Faceplate is a flush-mounted triplex modular faceplate designed for use in modular furniture raceway covers. The M13CLS hold up to three M-series or fibre modular telecommunications outlets and has numbering on both sides of the faceplate for installation and maintenance identification. The M20AP dust cover/blank can be used to protect unused outlets and cover unused faceplate openings.
Figure 112 M13CIS WLC Adapter
Physical Specifications Width: 7.9 cm Length: 4.6 cm Depth: 0.51 cm Plastic: High-impact, flame-retardant, UL-rated 94 V-0 thermoplastic
Product
Comcode
Packaging
Colour
M13CLS-246
108564675
1/Pkg
Ivory
M13CLS-262
108564683
1/Pkg
White
M13CLS-270
108564691
1/Pkg
Gray
M13CLS-003
108564709
1/Pkg
Black
M13CLS-215
108564725
1/Pkg
Creme
OUTLETS 179
OUTLETS
Fibre
Surface Mounted
Fibre
Surface Mounted
Outlets Contents Page
The Surface Mounted Fibre Outlet provides termination for two buffered fibres. The outlet can be surface mounted, fuse box mounted (60mm x 60mm box), or mounted on any type of electrical trunking. The Surface Mounted Fibre Outlet retains the slack fibre and controls the minimum bending radius of the individual fibre. They are available to terminate either ST or SC Duplex connectors. There is provision for circuit labelling. The Fibre Outlet comes packaged with its fibre-routing Figure 113
base, cover, cable tie for securing the LGBC, and blank
Surface Mounted
identification label.
Fibre Outlet
The Fibre Outlets come with an additional fusion splice holder. This splice holder can take a maximum of 4 fusion splices and is specifically designed for fusion splices with a length of 40 to 60 mm and a diameter of 3mm.
Physical Specifications Width: 8.4cm Length: 11.0cm Depth: 4.3cm
OUTLETS
900 µm Buffered Fibre Bending Radius: 20mm
180
Product
Comcode
Ports
Colour
Packaging
Fibre Outlet
407050988
2x ST cpl
1/Pkg
Ivory
Fibre Outlet
407036763
2x ST cpl
1/Pkg
White
Fibre Outlet
407036002
1x SC DPLX cpl
1/Pkg
Ivory
OUTLETS
Multimedia
Surface Mounted
Multimedia
40A1 Outlet
Outlets Contents Page
The 40A1 is a surface-mounted multimedia outlet box. Its modular design makes it adaptable, via panel inserts (ordered separately), for termination of fibre optic and/or copper cables. The 40A1 can accept two modular panels which hold the copper or fibre terminations. Some of the available panels are: 40ST4 which accepts 4 ST couplings, M40DSC which accepts 4 duplex SC couplings, and the M40RJ4A which accepts 4 M-Series High Density Modules. Figure 114 40A1 Multimedia Outlet,
The cover of the outlet has six knockouts for surface-run
40ST4 and M40DSC Panels
cable entry from several directions and can be mounted directly on a wall or over a US standard electrical box. The M40 outlet comes equipped with one M40RJ4A and one M40ST8 panel. Other panels must be ordered separately. The panels are orderable in minimum quantities of 10 panels per order.
Physical Specifications Outlet Height: 17.5cm Outlet Width: 14.2cm Outlet Depth: 4.1cm Panel Height: 3.7cm Panel Width: 6.7cm Panel Depth: 5.3cm
Product
Comcode
Ports
Packaging
Colour
M40A1-B-262
107992927
Basic Outlet w/ M40RJ4A and M40ST8
1/Pkg
White
M40ST4-B-262
107800658
Insert Panel holds 4 ST Couplings
1/Pkg
White
107239493
Insert Panel holds 4 Duplex SC Couplings
1/Pkg
White
M40RJ4A-B-262
108004268
Insert Panel holds 4 RJ45 Jacks, 4 M81 Mounting Modules
1/Pkg
White
OUTLETS
M40DSC-B-262
181
182
Connectors Chapter
5
183
Connectors Contents
ClickHere Main Menu
Copper R J 4 5 FA M I LY 700A8
185
Fibre L C FA M I LY LC Connectors
186
LazrSPEED™
189
LC Couplings
190
S C FA M I LY SC Connectors
191
SC Connector Clip
192
SC Couplings
193
S T FA M I LY
184
ST Connectors
194
ST Couplings
196
CONNECTORS
Copper
700A8
RJ45 Family
700A8 Plug
Connectors Contents Page
The 700A8 Modular Wire Plug is a modular 4-pair plug that attaches to 0.511 mm diameter (24 AWG) solid wire to create a modular cord. This field mountable plug can be used to make an RJ45 interface plug with customised pinout. The 700A8 can be used for voice and data applications Listed
running under 10 Mb/s.
Figure 115 700A8 Plug
Physical Specifications Width: 2.5cm Length: 4.0cm Depth: 1.3cm Plastic: High-impact, flame retardant, UL-rated 94V-0 thermoplastic
Product
Comcode
Packaging
Colour
700A8
103941472
1/Pkg
Beige
CONNECTORS 185
CONNECTORS
Fibre
LC Connectors
LC Family
LC 900µm Buffered Fibre Connector
Connectors Contents Page
The LC is a revolutionary fibre optic connector. This small form factor connector is only half the size of ST or SC connectors yet it has superior optical performance and reduced installation time. It uses the familiar insertion release mechanism similar to an RJ45 plug and has a Pull-Proof design. Fast becoming the connector of choice, the physical and optical performance of the LC allows engineers to design optical fibre infrastructures suited to
Figure 116
the low loss needs of the High Speed Data Networks.
P1001A LC Connector, Duplex
The LC offers a complete connection solution with a
MM LC Patch Cord
product range designed for Field Termination onto 900µm
and C1001B-2
Buffered Fibre, 1.6mm Fibre Cordage, Multimode and
Adapter
Singlemode Fibre. The high-performance LC Connector is the recommended connector for all SYSTIMAX® SCS installations. The superior insertion loss performance offered by the LC makes it the ideal connector for gigabit applications including all proposed 10 Gigabit Ethernet specifications for multimode and singlemode fibre. 900µm Fibre Connector This connector is designed to allow for the simple and speedy termination of the connector onto 900µm Fibre. So whether terminating a cable into a patch panel, connection box, or outlet, the LC offers the best in class solution.
Physical Specifications CONNECTORS
Length: 3.2cm Tip Material: Ceramic Insertion Loss: Mean = 0.1dB Standard Deviation: 0.1dB Return Loss: -20dB Insertion Loss Change: <0.3dB Mating durability for 500 reconnect Cable Retention: <0.3dB Temperature stability -40 to 75ºC
Optical Specifications Multimode: Average Loss: 0.1 dB Standard deviation 0.1dB Singlemode: Average Loss: 0.2 dB Standard deviation 0.1dB
186
Product
Comcode
O. D.
Mode
Packaging
P1001A-Z-125
700007008
900 µm
MM
1/Pkg
P1101A-Z-125
700011372
900 µm
SM
1/Pkg
P1001A-Z-125/100
700006299
900 µm
MM
100/Pkg
CONNECTORS
Fibre
LC Connectors
LC Family
LC 1.6 mm Jumper Connector
Connectors Contents Page
The LC Fibre Optic Simplex and Duplex Jumper Connectors can be used to terminate simplex and duplex 1.6mm jumper cords. It is intended for use in Central Offices, Local Area Networks (LANs), and in patch cords for Premises Distribution Systems. The connector can also be used in computer backplane connections, computer peripheral interconnections, device terminations, and other applications where quality, small-size, high-density, low-loss, and a low-cost infrastructure are required. Figure 117 LC 1.6mm Jumper Connector
Product
Comcode
O. D.
Fibre Type
Fibre Count
Packaging
P1000A-Z-125
700004260
1.6mm
MM
1
1/Pkg
P1002A-Z-125
700006992
1.6mm
MM
2
1/Pkg
P1002A-Z-125/100
700006307
1.6mm
MM
2
100/Pkg
CONNECTORS 187
CONNECTORS
Fibre
LC Connectors
LC Family
QwikCrimp™ LC Connector
Connectors Contents Page
The LC QwikCrimp Connector design is installed by “crimping” onto a stripped and cleaved multimode fibre. Field installation requires no epoxies or polishing. It is intended for “behind the wall” applications in protected building environments. It is designed for use on OptiSPEED™ and LazrSPEED™. These cables are designed to be mated to an LC (spring loaded) Patch Cord connector. Applications - Fibre optic communication network interfaces - Building LAN and campus WAN applications
Figure 118 QwikCrimp
- Behind the Wall (BTW) installations - 900µm O.D. Buffered OptiSPEED MM Fibre
CONNECTORS
- 62.5/125µm and LazrSPEED
188
Product
Comcode
Packaging
P1001C-Z-125
108635079
1/Pkg
P1001D-Z-125
108635087
1/Pkg
CONNECTORS
Fibre
LazrSPEED
LC Family
LazrSPEED Duplex Couplings
Connectors Contents Page
LazrSPEED Duplex Couplings are colour coded for easy fibre identification, and are available in LC (recommended) and SC versions.
Product
Comcode
Fibre Type
Connector Type
Packaging
C1001B-2-LS
108622887
MM
LC Coupling
1/Pkg
C6061A-4-LS
108622895
MM
SC Coupling
1/Pkg
CONNECTORS 189
CONNECTORS
Fibre
LC Couplings
LC Family
Duplex Couplings
Connectors Contents Page
The LC Duplex Coupling accommodates 2 LC connectors while only occupying the space of a simplex SC coupling. It features a self-adjusting mechanism designed to accommodate panel thickness variations from 1.55 to 1.75 mm (0.06 to 0.067 inches). It is available in both singlemode and multimode.
Figure 119 P1001A LC Connector, Duplex MM LC Patch Cord and
CONNECTORS
C1001B-2 Adapter
190
Product
Comcode
Fibre Type
Packaging
Colour
C1001B-2
700002355
MM
1/Pkg
Ivory
C1101A-2
700002215
SM
1/Pkg
Blue
CONNECTORS
Fibre
SC Connectors
SC Family
SC Connectors
Connectors Contents Page
The SC Multimode Fibre Optic Connector is a field mountable, tuneable connector which utilises a domed zirconia ferrule for fibre alignment, and push-pull hardware that provides easier connections as well as high optical stability. The connector can be used in high-density applications while not being affected by axial cable loads. The cable is crimped to the outer hardware and therefore prevents momentary disconnect when axial load is placed on the cable. Available in multimode and singlemode versions.
Figure 120 P6200A SC
The P6000A-Z-125 & P6200A-Z-126 can mount on 3.0 mm
Connector
cordage only while the P6001A-Z-125 & P6201A-Z-126 mounts on the 0.9 mm buffered fibre.
Physical Specifications Length: 5.0cm Loss Repeat (200 reconnects): < 0.3 dB Min. Axial Load: Cable: 13.6 kg; Buffer: 0.9 kg Temperature Stability (-40 to 75 (C): < 0.3 dB increase
Optical Specifications Average Loss MM: 0.3 dB Average Loss SM: 0.2 dB (Tuned) Average Loss SM: 0.3 dB (Untuned)
Comcode
O. D.
Fibre Type
Packaging
P6200A-Z-126
700007040
3.0 mm
MM
1/Pkg
P6201A-Z-126
700007024
900 µm
MM
1/Pkg
P6000A-Z-125
700006984
3.0 mm
SM
1/Pkg
P6001A-Z-125
700006976
900 µm
SM
1/Pkg
CONNECTORS
Product
191
CONNECTORS
Fibre
SC Connector Clip
SC Family
SC Connector Clip
Connectors Contents Page
The 2A1 Duplex Connector Clip accepts two simplex SC connectors to form a single duplex connector. The 2A1 is made of black plastic.
Figure 121 2A1 Connector
CONNECTORS
Holder
192
Product
Comcode
Packaging
2A1
700002165
10/Pkg
CONNECTORS
Fibre
SC Couplings
SC Family
Simplex Coupling
Connectors Contents Page
The C6000A-4 Coupling accommodates the multimode or singlemode simplex SC connector plugs and ensures the proper alignment of the fibres. This coupling is easily mounted by snapping them into the coupling panel. The coupling has a ceramic sleeve
Figure 122 C6000A-4 SC Coupling
Product
Comcode
Fibre Type
Packaging
C6000A-4
700004807
SM/MM
1/Pkg
Fibre
SC Couplings
SC Family
Duplex Coupling The SC Coupling accommodates the multimode or singlemode duplex SC connectors and ensures the proper alignment of the fibres. This coupling is easily mounted by snapping them into the coupling panel. The C6061A-4 sleeve is metallic and the C6060A-4 sleeve is ceramic.
CONNECTORS
Figure 123 C6061A-4 SC Duplex Coupling
Product
Comcode
Fibre Type
Packaging
Colour
C6061A-4
700004880
MM
1/Pkg
Beige
C6060A-4
700004815
SM/MM
1/Pkg
Blue
193
CONNECTORS
Fibre
ST Connectors
ST Family
STII Connectors
Connectors Contents Page
The STII Connector Plug is a keyed ceramic fibre optic connector plug that uses a bayonet-type “ramped-latching” mounting arrangement. The connector features a unique flexible split ferrule sleeve for accurate alignment of connector plugs. The ferrule is made of aluminium which provides for easy, accurate field polishing. STII Connectors will accept 125 micron outside diameter multimode fibre. The design of the STII provides high optical performance and easy mounting in a rugged, compact connector plug. Figure 124
The STII can mount on either 0.9 mm buffered fibre,
P2020C ST Connector
2.4 mm 2000 Series, or 3.0 mm 9000 Series cordage (or equivalent). The STII is available in both singlemode and multimode.
Physical Specifications Length: 5.64cm Temperature Stability (-40 to 85ºC): < 0.1 dB increase Loss Repeat (500 Reconnectors): <0.2dB Min. Axial Load - Cable: 15.9kg
Optical Specifications Multimode Average Loss: 0.3 dB
CONNECTORS
Singlemode Average Loss: 0.2 dB
194
Product
Comcode
O.D.
Fibre Type
Tip
Packaging
P2020C-C-125
700004583
900 µm/2.4mm/3.0mm
MM
Ceramic/Alumina
1/Pkg
P2020C-C-125/100
700004336
900 µm/2.4mm/3.0mm
MM
Ceramic/Alumina
100/Pkg
P2020C-Z-125
700004328
900 µm/2.4mm/3.0mm
MM
Ceramic/Zirconia
1/Pkg
P2020C-Z-125/100
700004310
900 µm/2.4mm/3.0mm
MM
Ceramic/Zirconia
100/Pkg
P3020A-Z-125
700011067
900 µm/2.4mm/3.0mm
SM
Ceramic/Zirconia
1/Pkg
CONNECTORS
Fibre
ST Connectors
ST Family
STII + Connector
Connectors Contents Page
The STII+ Connector Plug is a keyed fibre optic connector plug that uses a bayonet-type “ramped-latching” mounting arrangement. The STII+ has a patented enhanced hardware design which provides high performance and easy field mounting. It features a domed zirconia ferrule and utilises a PC polish to ensure fibre-to-fibre physical contact for low loss and low reflections. Its enhanced hardware and pull proof design provides high mechanical stability. The STII+ can mount on either 0.9 mm buffered fibre or Figure 125
on 3.0 mm 9000 Series cordage (or equivalent). When
P2070C STII+
mounted on cordage, the cable is crimped to the outer
Connector
hardware, preventing momentary disconnect when axial load is applied. The STII+ is available in both multimode and singlemode.
Physical Specifications Length: 5.64cm Loss Repeat (500 reconnects): < 0.3 dB Min. Axial Load: Cable: 15.9 kg; Buffer: 0.9 kg Temperature Stability (-40 to 85ºC): < 0.3 dB increase
Optical Specifications Average Loss: 0.3 dB
Comcode
O.D.
Fibre Type
Packaging
P2070A-Z-125
700002389
900 µm/3.0 mm
MM
1/Pkg
P2070A-Z-125
700005556
900 µm/3.0 mm
MM
100/Pkg
P3070A-Z-125
700002231
900 µm/3.0 mm
SM
1/Pkg
CONNECTORS
Product
195
CONNECTORS
Fibre
ST Couplings
ST Family
ST Couplings
Connectors Contents Page
The C2000A and C3000A Couplings accommodate the ST, STII, and STII+ Connector plugs and ensure the proper alignment of the fibres. The coupling is based on a longitudinally split sleeve; the thickness of the sleeve’s wall varies, causing its inside diameter to remain circular even when a cylindrical ferrule forces it open. The connector coupling is designed for use with all ST connector panels in LIU’s, LGX’s, 660A1, 600B2 and fibre outlets. The C2000A Coupling is packaged with the coupling Figure 126
itself, lock washer and hex nut for mounting onto the
C2000A2
CONNECTORS
coupling panels.
196
ST Coupling
Product
Comcode
Fibre Type
Packaging
C2000A-2
700004864
MM
1/Pkg
C2000A-2/100
700004906
MM
100/Pkg
C3000A-2
700011133
SM
1/Pkg
Adapters Chapter
6
197
Adapters Contents
Click Here Main Menu
Copper CONNECTIVITY RJ45 to RJ45 Adapter
199
RJ45 to 110
200
RJ45 to 50-Pin
201
RJ45 to DB-25
203
RJ45 Splitters
205
RJ45 Bridge
207
TRANSMISSION
198
Token Ring 4/16 Mb/s
208
IBM AS/400
209
IBM 3170/3270
211
EIA-232-D
212
Video
214
ISDN
225
ADAPTERS
Copper
RJ45 to RJ45 Adapter
Connectivity
451A Adapter
Adapters Contents Page
The 451A Adapter is an in-line, double-ended RJ45 modular jack that accepts either an RJ45 or RJ11 modular plug. It is a type of coupler used to connect two modular cords, maintaining proper continuity/polarity. These adapters are not suitable for applications running Listed
above 10 Mb/s.
Figure 127 451A Adapter
Physical Specifications Height: 16mm Width: 16mm Depth: 40mm
Product
Comcode
Packaging
Colour
451A-50
103786240
1/Pkg
Ivory
451A-61
103942272
1/Pkg
Grey
ADAPTERS 199
ADAPTERS
Copper
RJ45 to 110
Connectivity
1110A1 Adapters
Adapters Contents Page
The 1110A1 Modular Adapters are 1-piece devices available in 3 or 4-pair sizes for terminating modular RJ45 Connectors onto the 110 Connector System. One side is equipped with blades that sit in the insulation displacement clip of the 110 Connecting Block. The other side is equipped with a 4-pair modular RJ45 jack. Each adapter has a label attached to its underside which provides a wiring diagram to show pairs and standard pinout. The word “TOP“ is stamped on the adapter Listed
for orientation.
Figure 128 1110A1-3 and 1110A1-4 Adapters
Figure 129 1110A1-3 and
ADAPTERS
1110A1-4 Pinout
200
Product
Comcode
Pair Size
Packaging
1110A1-3
406678755
3
1/Pkg
1110A1-4
406678763
4
1/Pkg
ADAPTERS
Copper
RJ45 to 50-Pin
Connectivity
258 Adapters
Adapters Contents Page
The 258-Type Adapter has a 50-pin, male or female telco connector, which distributes the pairs from a 25-pair connectorised telco cable to six 8-pin modular RJ45 jacks. The 258-Type is available with either the jacks located perpendicular (the A series), or parallel to the telco connector (the B series). These adapters can support applications running at 10 Mb/s or less. Figure 130 258A, 258B and 356A Adapters
Gender
Figure 131 258A Pinout
Product
Comcode
Connector Type
Telco Gender
Packaging
258A
102605136
50-pin telco to 6x RJ45 Jacks - Perpendicular
Male
1/Pkg
258AF
103796561
50-pin telco to 6x RJ45 Jacks - Perpendicular
Female
1/Pkg
258B
103923025
50-pin telco to 6x RJ45 Jacks - Parallel
Male
1/Pkg
ADAPTERS 201
ADAPTERS
Copper
RJ45 to 50-Pin
Connectivity
356A Adapter
Adapters Contents Page
The 356A Adapter has a 50-pin, male or female telco connector, which distributes the pairs from a 25-pair connectorised telco cable to eight 8-pin RJ45 modular jacks Listed
(only six of the eight pins are connected on each jack). The adapters are used to join connectorised 25-pair cable to 4-pair cords equipped with RJ45 modular plugs, such as linking clusters of balun adapters onto UTP connecting hardware in a telecommunication closet, equipment room, or computer room. These adapters should not be used with devices that require connections to all eight pins of
Figure 132
the RJ45. The 356A can support applications running at
356A Pinout
ADAPTERS
10 Mb/s or less.
202
Product
Comcode
Connector Type
Telco Gender
Packaging
356A
104158829
50-Pin telco to 8x RJ45 Jacks
Male
1/Pkg
ADAPTERS
Copper
RJ45 to DB-25
Connectivity
355 Adapter
Adapters Contents Page
The 355-Type Adapters are used to adapt an EIA-232-D 25pin connector to an RJ45 modular jack. The adapter helps protect asynchronous equipment against damage from ringing voltages and standard battery power. It is not necessary to use a 355 Adapter if an Asynchronous Data Unit (ADU) is in place. The 355A supports software flow control or no flow control, while the 355B supports
Figure 133
hardware flow control, software flow control, or no flow
355 Pinout
control. Both adapters are available with either male or Listed
female 25-pin connectors.
Physical Specifications Height: 1.75cm
Weight: 41 g
Width: 4.40cm
Temperature: 4 to 49ºC
Depth: 6.35cm
Humidity: 5-95% (noncondensing)
Product
Comcode
Connector Type
Packaging
355A
105012637
Male EIA-232 to RJ45 Jack
1/Pkg
355AF
105012645
Female EIA-232 to RJ45 Jack
1/Pkg
355B
104270723
Male EIA-232 to RJ45 Jack
1/Pkg
355BF
104270731
Female EIA-232 to RJ45 Jack
1/Pkg
ADAPTERS 203
ADAPTERS
Copper
RJ45 to DB-25
Connectivity
368A Adapter
Adapters Contents Page
The 368A Adapter Kit is a customer-configurable kit that is used to adapt an EIA-232-D 25-pin connector to an RJ45 modular jack. The kit can be ordered with either a male or female DB25 Connector. All components snap together for easy assembly. The kit includes: - One DB25 Connector (male or female) with captive screw - One 8-position, 8-conductor modular jack with eight leads Figure 134
- One plastic housing (two-sides)
368A Adapter Kit
ADAPTERS
- Two jumper leads.
204
Product
Comcode
Connector Type
Packaging
368A
105345342
Male DB-25 To RJ45 Jack
1/Pkg
ADAPTERS
Copper
RJ45 Splitters
Connectivity
400K Splitter
Adapters Contents Page
The 400K Splitter has one 8-pin RJ45 modular plug wired to two modular jacks. One of the jacks is an 8-position RJ45 with all 8 conductors connected, the other jack is a 6-position RJ11 with only two conductors connected (pair 1). The 400K is used to split a single RJ45 outlet so that an application (using pairs 2, 3, and/or 4) can share the outlet with an analogue telephone (which uses pair 1). The adapter can support applications running at 10 Mb/s or Listed
less. The 400K is category 3 compliant. Figure 135 400K Splitter
Figure 136 4400K Pinout
Product
Comcode
Packaging
400K
105307177
1/Pkg
ADAPTERS 205
ADAPTERS
Copper
RJ45 Splitters
Connectivity
400E Splitter
Adapters Contents Page
The 400E Splitter has one 8-pin RJ45 modular plug wired to two 6-position, 4-pin RJ11 modular jacks. Of the RJ45 plug, pairs 1 & 2 are wired to the first RJ11 jack, and pairs 3 & 4 are wired to the second RJ11 jack. The 400E is used to split the 4-pair RJ45 input into two 2-pair RJ11 outputs. The adapter can support applications Listed
running at 10 Mb/s or less. The 400E is category 3 compliant.
Figure 137 400E Adapter
Figure 138
ADAPTERS
400E Pinout
206
Product
Comcode
Packaging
400E
103895538
1/Pkg
ADAPTERS
Copper
RJ45 Bridge
Connectivity
367A Bridging Adapter
Adapters Contents Page
The 367A Bridging Adapter has eight 8-pin RJ45 modular jacks (internally bridged together) and is used to connect up to seven workstations in a multipoint environment to an IBM System 36/38 or IBM AS/400 host port via the 365A Balun Adapter. This adapter may further be used with other applications that require a bridged configuration (See Listed
Avaya’s Application Guides for design guidelines).
Figure 139 367A Adapter
Figure 140 367A Pinout
Product
Comcode
Ports
Packaging
367A
105275606
8x RJ45 Jacks
1/Pkg
ADAPTERS 207
ADAPTERS
Copper
Token Ring 4/16 Mb/s
Transmission
370C1 Media Filter
Adapters Contents Page
The 370C1 Adapter is an unshielded twisted-pair media filter for use with the IBM 4/16 Mb/s Token Ring Local Area Network (LAN). This adapter eliminates the need for shielded twisted-pair cable when connecting the IBM 4/ 16 Mb/s Token Ring Network Interface Adapter. 370C1 Adapters can be used to provide connectivity between IBM 8220 Fibre Converters and IBM 8228 Multistation Access Units (MAUs) to create a token ring network using SYSTIMAX® SCS cabling. The 370C1 attaches the workstation to the network cabling system and provides longitudinal filtering, balancing, impedance matching, and
Figure 141
interfaces to both SYSTIMAX SCS 1061/2061 and 1071/2071
370C1 Media Filter
Enhanced Performance and 1010/2010 LAN Cable. The 370C1 can support 104 token ring workstations over 1061 or 2061 cable at a maximum distance of 100m (328ft) and 72 workstations over 1010 or 2010 cable at a maximum distance of 38.1m (125ft). The 370C1 has a 9-pin DB9 connector on one side. This connector attaches to the IBM 16/4 Mb/s Token Ring Adapter and plugged into a personal computer (PC). On the other side of the 370C1 Adapter is a 3.81cm (12.5ft) section of 4-pair modular cord that terminates in an 8-position modular plug. The modular plug connects the adapter to the unshielded twisted-pair cable of SYSTIMAX Listed
SCS via the workstation outlet at the workstation location. See the Avaya publicised “IBM Token Ring Application Guide” for design/configuration guidelines. The 370C1 is UL listed.
ADAPTERS
Physical Specifications Height: 1.9cm
Weight: 170g
Width: 3.5cm
Temperature: 0 to 60ºC
Depth: 6.9cm
Humidity: 5-95% (noncondensing)
Cord length: 4.5m
Electrical Specifications Impedance: Source: 150 Ω Unbal. Twisted Pair: 100 Ω Bal.
208
Product
Comcode
Packaging
Colour
370C1
106563919
1/Pkg
Grey
ADAPTERS
Copper
IBM AS/400
Transmission
365A & 366A Baluns
Adapters Contents Page
The 365A Balun Adapter is a twinaxial-to-twisted-pair balun that eliminates the need for twinaxial cable to connect equipment in an IBM System 34/36/38 or an IBM Application System/400 (AS/400) product line environment. The adapter balances the unbalanced twinaxial signals from the IBM equipment so that they are compatible with SYSTIMAX SCS unshielded twistedpair wiring. Each 365A consists of a flame-retardant plastic housing with a short section of twinaxial cable on one side, terminated with a male twinaxial connector. The
Figure 142
other side of the adapter contains an 8-pin modular jack
365A Balun and 366A
for attaching an 8-conductor D8W Workstation Line Cord
Terminating Adapters
(sold separately). A 366A Terminating Adapter is packaged with each 365A Balun Adapter. The 366A is used to terminate the unshielded twisted-pair leads at the information outlet to minimise signal reflections if a workstation is discontinued. See the Avaya published “IBM System 36 and AS/400 Application Guide” for design/configuration guidelines. Listed
The 365A is UL Listed.
Physical Specifications Height: 2.79cm
Weight: 120g
Width: 4.19cm
Temperature: 0 to 60ºC
Depth: 20.6cm
Humidity: 5-95% (noncondensing)
Electrical Specifications Impedance Source: 110 Ω Unbal.
Twisted Pair: 100 Ω Bal.
Comcode
Packaging
Colour
365A
105282610
1/Pkg
Grey
366A
105272678
1/Pkg
White
ADAPTERS
Product
209
ADAPTERS
Copper
IBM AS/400
Transmission
369A Matching Adapter
Adapters Contents Page
The 369A Matching Adapter provides an impedancematching network that minimises signal reflections back to the host port when bridging between two and seven workstations on SYSTIMAX SCS. It is used with the 365A Balun Adapter to connect IBM workstations to an Application System/400 (AS/400) host over SYSTIMAX SCS. The 369A consists of a plastic housing with a short section of cord on one side terminating in an 8-position modular plug. The other side of the housing contains an 8-pin modular jack.
Figure 143 369A Matching Adapter
The 369A Matching Adapter is required in all multipoint arrangements involving an AS/400 or a 5294/5394 Remote Control Unit and is compatible with all other IBM workstations designed for twinaxial cable connection to an AS/400 or 5294/5394 Remote Control Unit. It is used with the 365A Balun Adapter to connect IBM workstations to an AS/400 host over SYSTIMAX SCS. See the Avaya published “IBM System 36 and AS/400 Application Guide” for design/configuration guidelines. Listed
The 369A Adapter is UL Listed.
ADAPTERS
Physical Specifications
210
Height: 1.78cm
Weight: 84g
Width: 2.03cm
Temperature: 0 to 60ºC
Length (with cord): 8.13cm
Humidity: 5-95% (noncondensing)
Product
Comcode
Packaging
Colour
369A
105689772
1/Pkg
Black
ADAPTERS
Copper
IBM 3170/3270
Transmission
353A3 Balun
Adapters Contents Page
The 353A3 Balun Adapter is a coaxial-to-twisted-pair balun that eliminates the need for coaxial cable to connect IBM 3170 and 3270 -Type data equipment using the Type A protocol. The adapter balances the unbalanced coaxial signals from the IBM equipment so that they are compatible with SYSTIMAX SCS. The 353-Type Adapter is used for both the workstation and the controller (or multiplexer). The 353A3 Balun Adapter consists of a BNC coaxial connector, a balanced-unbalanced network coupler, a 3.81m (12.5ft) section of 4-pair cable, and an 8-position RJ45 modular plug. Signals are transmitted to the UTP wiring through Pins 1 and 2 of the adapter's modular plug. One 353A Balun Adapter is Listed
needed for each workstation. See the Avaya published 'IBM 3270 Application Guide' for design/configuration guidelines
Physical Specifications Length (with cord): 381cm
Temperature: 0 to 60ºC
Weight: 110g
Humidity: 5-95% (noncondensing)
Electrical Specifications Impedance: Source: 93 Ω Unbal.; Twisted Pair: 100 Ω Bal. Bandwidth: 100 kHz to 10 MHz
Product
Comcode
Ports
Packaging
353A3
106503394
BNC To RJ45 Plug
1/Pkg
ADAPTERS 211
ADAPTERS
Copper
EIA-232-D
Transmission
Z3A Asynchronous Data Unit
Adapters Contents Page
The Z3A Series of Asynchronous Data Units (ADUs) extend the distance over which asynchronous, Electronic Industries Association (EIA)-232-D devices can transmit signals. The units modify the signals so that they may be sent over SYSTIMAX SCS unshielded twisted-pair cable. The recommended EIA-232-D transmission distance can be extended to distances up to 12.2km (40,000ft) with ADUs. ADUs also make it possible for EIA-232-D signals to share cable with analog voice signals. The Z3A ADU complies with FCC Rules and Regulations Part 15 for Class A Computing Devices. There are two models of Z3A Adapters:
Figure 144 Z3A Asynchronous Data
The Z3A2 has a male EIA-232-D on one end and two modular jacks at the other end, one for a wall jack connection and one for a telephone connection. The Z3A3 is designed for use in telecommunications closets and has two 12.3m (7ft) patch cords, labelled “Station” and “Concentrator,” to attach the Z3A3 to unshielded twistedpair connecting hardware. See the Avaya published “EIA232-D Application Guide” for design/configuration guideListed
lines. The Z3A2 ADU is UL Listed.
Physical Specifications Length: 11.8cm
Weight: 110g
Width: 5.46cm
Temperature: 4 to 60ºC
Height: 2.34cm
Humidity: 5-95% (noncondensing)
ADAPTERS
Product
212
Comcode
Ports
Packaging
Z3A2
103963971
Male EIA-232 to 2x RJ45 Jacks
1/Pkg
Z3A3
103963989
N/A
1/Pkg
ADAPTERS
Copper
EIA-232-D
Transmission
Z3B1 Synchronous Data Unit
Adapters Contents Page
The Z3B1 Synchronous Data Unit (SDU) is a limiteddistance modem that extends the distance over which synchronous, EIA-232-D devices can transmit signals. The SDU modifies the equipment signals so that they may be transmitted over SYSTIMAX SCS. With SDUs used in pairs, the recommended maximum EIA-232-D transmission distance can be extended up to 3.20 km (2.0 miles) at a data rate of 19.2 kb/s and up to 5.02 km (3.12 miles) at a data rate of 9.6 kb/s. Each SDU consists of a plastic housing with a female,
Figure 145
EIA-232-D, 25-pin, sub-miniature D-Type connector on one
Z3B1 Sync Date Unit
end and a 3.66m (12ft) section of 2-pair cable terminated in an 8-position RJ45 modular plug on the other end. The DCE-Type EIA-232-D interface is designed to be plugcompatible with a DTE-Type EIA-232-D interface. The Z3B1 requires the use of a D8AM-87 Crossover Cord (sold separately) to connect to SYSTIMAX SCS. See the Avaya published “EIA-232-D Application Guide” for Listed
design/configuration guidelines. The Z3B1 is UL Listed.
Physical Specifications Height: 2.29cm
Weight: 210g
Length: 10.9cm
Temperature: 0 to 60ºC
Width: 5.33cm
Humidity: 5-95% (noncondensing)
Comcode
Length
Packaging
Z3B1
405245028
Female DB-25 To RJ45 Plug
1/Pkg
ADAPTERS
Product
213
ADAPTERS
Copper
Video
Transmission
380A Baseband Video and Audio Adapter
Adapters Contents Page
The 380A Video Adapter is a baseband video/high-fidelity audio adapter that provides connectivity to the 1010/ 2010, 1061/2061, or 1071/2071 24-AWG unshielded twistedpair cable of SYSTIMAX SCS. The 380A Video Adapter is used in pairs to transmit National Television Standards Committee (NTSC) and Phase-Alternation Line (PAL) standard composite video and dual-channel high fidelity audio signals. The 380A is connected to the building wiring at an information outlet (IO) in the work area and to SYSTIMAX SCS unshielded twisted-pair connecting hardware in the
380A Baseband
telecommunications closet or equipment room.
Video Adapter
The 380A can be mounted on the equipment in the work area using the adhesive-backed Velcro strip provided, or it may be panel mounted in the work area or telecommunications closet or equipment room using screws and the mounting holes. Six 380As can be installed on the 811A panel. The 811A Panel is a sheet-metal panel that mounts on a standard Electronic Industries Association (EIA) 48.3cm (19in) rack or on a wall. The 811A Panel is 4.5cm (1.8in) high and occupies one rack unit (1U). The 380A Video Adapters can be installed,removed, or rearranged in the 811A Panel Listed
either before or after it is mounted. See the Avaya published “Baseband Video Application Guide” for design/configuration guidelines. The 380A is UL Listed.
ADAPTERS
Physical Specifications Height: 2.0cm
Weight: 90g
Depth: 6.9cm
Temperature: 0 to 60ºC
Width: 5.8cm
Humidity: 5-95% (noncondensing)
Connections Video: BNC (Female) Audio: Standard Phono Jack (2) Output: 8-Position Modular Jack
Electrical Specifications Video Bandwidth: DC to 8 MHz
Audio Bandwidth: 50 Hz to 15 kHz
Video Input Impedance (Source): 75 Ω Unbal.
Audio Input Impedance (Source): 600 Ω Unbal.
Video Output Impedance (Twisted Pair): 100 Ω Bal.
Audio Output Impedance (Twisted Pair): >600 Ω Bal.
Video Common Mode Rejection @ 50 MHz: >40 dB
Audio Common Mode Rejection @ 100 kHz: >40 dB
Tested to FCC Rules and Regulations Part 15 and CISPR Pub. 22 for Class B Computing Devices
214
Figure 146
ADAPTERS
Copper
Video
Transmission
380A Baseband Video and Audio Adapter (contd)
Adapters Contents Page
OPERATIONAL DISTANCES Cable Type
Distance
Black & White
1010/2010
365m (1200ft)
670m (2200ft)
Product
Comcode
Ports
Packaging
380A
106727944
1x BNC + 2x RCA To RJ45 Jack
1/Pkg
811A Panel
106976541
1/Pkg
ADAPTERS 215
ADAPTERS
Copper
Video
Transmission
380B Baseband Video Adapter
Adapters Contents Page
The 380B Video Adapter is a baseband adapter that provides connectivity over 1010/2010, 1061/2061 or 1071/2071 24-AWG unshielded twisted-pair cable for security and surveillance monitoring. It is used in pairs to transmit National Television Standards Committee (NTSC) and Phase-Alternation Line (PAL) standard composite video signals. The 380B supports end-user applications in various environments such as: educational institutions, airport displays, penal institutions, video bulletin boards, outdoor campus monitoring, video capture, product process
The 380B is enclosed in a hard plastic casing and is equipped with an 8-position/8-conductor modular jack and a single BNC jack. The BNC connects the adapter to the baseband video equipment and the modular jack connects to the SYSTIMAX SCS unshielded twisted-pair wiring infrastructure. A D8AU modular cord is used to provide the interface between the adapter and the modular jack. The 380B Video Adapter can be mounted on the equipment in the work area using the adhesive-backed Velcro strip provided, or it may be panel mounted in the work area or telecommunications closet using screws and the mounting holes. See the Avaya published “Baseband Video Application Guide” for design/configuration guidelines. The 380B is UL Listed.
ADAPTERS
Physical Specifications Height: 2.0cm
Weight: 90g
Depth: 6.9cm
Temperature: 0 to 60ºC
Width: 5.8cm
Humidity: 5-95% (noncondensing)
Connections Video: BNC (Female) Output: 8-Position Modular Jack
Electrical Specifications Bandwidth: DC to 8 MHz
Input Impedance (Source): 75 Ω Unbal.
Output Impedance (Twisted Pair): 100 Ω Bal.
Common Mode Rejection @ 50 MHz: >40 dB
Return Loss: >25 dB
Signal to Noise Ratio: >60 dB
Tested to FCC Rules and Regulations Part 15 and CISPR Pub. 22 for Class B Computing Devices
216
380B Baseband Video Adapter
monitoring, and remote medical video.
Listed
Figure 147
ADAPTERS
Copper
Video
Transmission
380B Baseband Video Adapter (contd)
Adapters Contents Page
OPERATIONAL DISTANCES Cable Type
Distance
Black & White
1010/2010
365m (1200ft)
670m (2200ft)
1061/2061/1071/2071
457m (1500ft)
762m (2500ft)
Product
Comcode
Ports
Packaging
380B
107136822
1x BNC, 1x RJ45
1/Pkg
ADAPTERS 217
ADAPTERS
Copper
Video
Transmission
380BA Baseband Video Adapter
Adapters Contents Page
The 380BA Video Adapter is an active (powered), coax-tounshielded twisted pair (UTP), closed circuit television (CCTV) distribution solution. This twisted-pair media device can deliver an analogue composite baseband video signal over a UTP cabling distance of up to 909m (3000ft) while ensuring a minimum receive signal of less than -3db, thus eliminating the need for coax. A certified SYSTIMAX SCS component, the 380BA is equipped with a BNC connector for CCTV signal input. Figure 148
So in combination with the 380B Adapter (on one end of
380BA Baseband
the cable), the 380BA (on the other end of the cable) can
Video Adapter
provide intrabuilding connectivity of baseband CCTV video and pan/tilt/zoom (PTZ) control signals. The 380BA uses existing building wiring and information outlets. The 380BA can be surface mounted either by using the adhesive-backed Velcro & No 153 strip provided or the screw tab holes. It can also be rack mounted using the 811A panel which can hold up to six 380B or 380BA Adapters. Listed
380BA is UL Listed
Physical Specifications Height: 2.0cm
Weight: 90g
Depth: 6.9cm
Temperature: 0 to 60ºC
Width: 5.8cm
Humidity: 5-95% (noncondensing)
Connections Video: BNC (Female)
ADAPTERS
Output: 8-Position Modular Jack (Female) Positions 7+8 Active
Electrical Specifications Bandwidth: DC to 8 MHz
Input Impedance (Source): 75 Ω Unbal.
Output Impedance (Twisted Pair): 100 Ω Bal.
Common Mode Rejection: >50 dB
Return Loss: >20 dB
Signal to Noise Ratio: >60 dB
Insertion Loss: < 1.0dB
OPERATIONAL DISTANCES Cable Type
218
Distance
1010/2010
636m (2100ft)
1061/2061/1071/2071
909m (3000ft)
Product
Comcode
Packaging
380BA
107988719
1/Pkg
ADAPTERS
Copper
Video
Transmission
381A RGB Video Adapter
Adapters Contents Page
The 381A Video Adapter is a baseband video adapter that provides connectivity to the 1010/2010, 1061/2061 or 1071/ 2071 24-AWG unshielded twisted-pair cable of SYSTIMAX SCS. The 381A Video Adapter is used in pairs to support all red-green-blue (RGB) video monitors up to resolutions of 640 by 480 pixels and refresh rates up to 72 Hz. The 381A is connected to the building wiring in the work area and to SYSTIMAX SCS unshielded twisted-pair connecting hardware in the telecommunications closet or equipment room.
Figure 149 381A RGB
The 381A can be mounted on the equipment in the work area using the adhesive-backed velcro strip provided, or it may be panel mounted in the work area or the telecommu-
Video Adapter
nications closet using screws and the mounting holes. Six 381As can be installed on the 811A Panel. The 811A Panel is a sheet-metal panel that mounts on a standard Electronic Industries Association (EIA) 48.3cm (19in) rack or on a wall. The 811A Panel is 4.5cm (1.8in) high and occupies one rack unit (1U). The 381A Video Adapters can be installed, removed, or rearranged in the 811A Panel either before or after it is mounted.
Listed
See the Avaya published “Baseband Video Application Guide” for design/configuration guidelines. The 381A is UL Listed.
Physical Specifications Height: 2.5cm
Weight: 90 g
Depth: 7.9cm
Temperature: 0 to 60ºC
Width: 6.2cm
Humidity: 5-95% (noncondensing)
Video: BNC (Female) x3
ADAPTERS
Connections Output: 8-Position Modular Jack
Electrical Specifications Bandwidth: DC to 30 MHz
Input Impedance (Source): 75 Ω Unbal.
Output Impedance (Twisted Pair): 100 Ω Bal.
Common Mode Rejection @ 50 MHz: >40 dB
Tested to FCC Rules and Regulations Part 15 and CISPR Pub. 22 for Class B Computing Devices
OPERATIONAL DISTANCES Cable Type
Distances
1010/2010
100m (328ft)
1061/2061/1071/2071
152m (500ft)
Product
Comcode
Ports
Packaging
381A
106857402
3x BNC to RJ45 Jack
1/Pkg 219
ADAPTERS
Copper
Video
Transmission
383A Video Distribution Amplifier
Adapters Contents Page
The 383A Distribution Amplifier is a baseband video/highfidelity audio distribution amplifier designed to provide connectivity to the SYSTIMAX SCS. The 383A transmits over 24-AWG unshielded twisted-pair 1010/2010, 1061/2061 or 1071/2071 LAN cable. The 383A is equipped with two BNC video jacks (input and output) and two sets of hi-fidelity audio jacks (input and output) located on the back panel. The BNC input jack is used to connect the composite video source. The standard phono input jacks are used to connect the audio source. The BNC output jack and standard phono output jacks are used to interconnect additional 383A Amplifiers. Six modular jacks, located on the front panel, provided the signal output to up to six remote locations. A maximum of ten 383A Distribution Amplifiers can be bridged together to deliver video and/or audio signals to 60 remote locations. A selector switch for bridged/unbridged applications is provided on Listed
the back of the 383A adapter. The 383A Distribution Amplifier is normally installed in a telecommunication closet or equipment room. Signals are transmitted to 380A adapters located in the work area. Interface to the Cabling System is achieved via modular cords connected to the building wiring at an RJ45 Jack Panel in the telecommunication closet. The power supply should be ordered separately. See the Avaya published “Baseband Video Application Guide” for design/configuration
ADAPTERS
guidelines. The 383A is UL Listed.
Physical Specifications Height: 4.1cm
Humidity: 5-95% (noncondensing)
Width: 21.6cm
Temperature: 0 to 50ºC
Depth: 19.4cm
Connections Video: BNC (Female) Audio: Standard Phono Jack Output: 8 Conductor, 8-Position Modular Jack
220
Figure 150 383A Baseband Video Distribution Amplifier
ADAPTERS
Copper
Video
Transmission
383A Video Distribution Amplifier (contd)
Adapters Contents Page
Electrical Specifications Video Bandwidth: DC to 8 MHz Audio Bandwidth: 50 Hz to 20 kHz Video Input Impedance (Source): 75 Ω Unbal. Audio Input Impedance (Source): 600 Ω Unbal. Video Output Impedance (Twisted Pair): 100 Ω Bal. Audio Output Impedance (Twisted Pair): >600 Ω Bal. Video Common Mode Rejection @ 50 MHz: >40 dB Audio Common Mode Rejection @ 100 kHz: >40 dB Power Supply: Output ± 12 V DC Signal to Noise: NTC 7 (unweighted) >60 dB Tested to FCC Rules and Regulations Part 15 and CISPR Pub. 22 for Class B Computing Devices
OPERATIONAL DISTANCES Cable Type
Distance
Black & White
1010/2010
365m (1200ft)
670m (2200ft)
1061/2061/1071/2071
475m (1500ft)
762m (2500ft)
Product
Comcode
Ports
Packaging
383A
107079642
2x BNC, 4x RCA, 6x RJ45
1/Pkg
383A Power Supply 220V
407004357
N/A
1/Pkg
ADAPTERS 221
ADAPTERS
Copper
Video
Transmission
384A Broadband Video Adapter
Adapters Contents Page
The 384A Video Adapter is a broadband (CATV) video device that performs common mode filtering, balancing and impedance matching to provide connectivity to SYSTIMAX SCS. It permits connectivity between broadband CATV video distribution equipment placed up to 100m (328ft) apart using Avaya Category 5 components (the distance limit is determined by the number of channels transmitted). Sheath sharing, within the same 4-pair cable, with baseband voice and/or data is supported. Figure 151
The 384A is equipped with an F-Type male connector plug
384A Broadband
on one end, and a 3.6m (12ft) section of 2-pair cordage with
Video Adapter
an RJ45 on the other. The RJ45 should be connected to the work area information outlet, or the modular RJ45 jack panel in the telecommunication closet or equipment room. The F-Type plug is used to connect to the broadband video distribution equipment. See the Avaya published “Video Application Guide” for design/configuration guidelines. Listed
The 384A is UL Listed.
Physical Specifications Length (Housing & F-Connector): 5.8cm
Cord Length: 3.6m
Electrical Specifications Bandwidth: 55 to 550 MHz
Input Impedance (Source): 75 Ω Unbal.
Output Impedance (Twisted Pair): 100 Ω Bal.
Common Mode Rejection @ 50 MHz: >40 dB
Signal to Noise Ratio: >60dB
Insertion Loss: <3 dB
Return Loss: >20 dB
ADAPTERS
Distance Supported (CISPR Class B): from 55.25 to 121.25 MHz: 100m from 127.25 to 151.25 MHz: 70m from 157.25 to 253.25 MHz: 50m Tested to FCC Rules and Regulations Part 15 and CISPR Pub. 22 for Class B Computing Devices
Connections Input: F-Type Connector Plug (Male) Output: 8-Position Modular Plug Positions 1+2 Active
222
Product
Comcode
Ports
Packaging
384A
107213605
F-Type to RJ45 Plug
1/Pkg
ADAPTERS
Copper
Video
Transmission
385DP Broadband Video Adapter
Adapters Contents Page
The 385DP Broadband CATV Distribution Panel allows analog broadband video distribution over enhanced Power Sum and GigaSPEED Solutions. The 19 inch wide rack mountable 385DP Broadband CATV Distribution Panel is a passive self-terminating 1 by 16 coax-to-UTP CATV distribution solution that provides connectivity over 1061/2061 or 1071/2071 SYSTIMAX SCS UTP LAN cables. The 385DP is equipped with an F-type coaxial input connector (female) and 16 8-pin output modular Listed
jacks (female). A single 385DP distributes CATV signals for up to 16 locations. The 385DP is typically installed in a telecommunications closet or equipment room and transmits CATV signals in the horizontal subsystem to 384A Adapters located in the work location.
Connections Input: F-Type Connector Jack (Female) Output: (16) 8-pin Modular Jacks (Female) Positions 1 & 2 active Emission: Tested to FCC Part 76 and CISPR 22 Class B Safety: UL, CSA, and IEC 950
Electrical Specifications Bandwidth: 5 MHz - 550 MHz
Total Channels (8 MHz per channel): 58 Channels
Insertion Loss: 14.5 dB Ω 0.5 dB
Return Loss: > 15 dB
Common Mode Rejection: > 40 dB
Signal to Noise Ratio: > 60 dB
Input Impedance: 75 Ohms
Isolation: > 20dB
Operational Distances 60 metres - 77 channels for a minimum received signal level of 0dBmV 100 metres - 28 channels for a minimum received signal level of 0dBmV
Product
Comcode
Packaging
385DP
108120460
1/Pkg
ADAPTERS
100 metres - 50 channels for a minimum received signal level of -10dBmV
223
ADAPTERS
Copper
Video
Transmission
386S Video Adapter The 386S Video Adapter is a passive S-Video/ high-fidelity audio surface mount adapter that provides point-to-point connectivity to the 1010/2010, 1061/2061, 1071/2071 24-AWG twisted-pair wiring of SYSTIMAX SCS. The 386S Adapter is intended to primarily support S-Video/audio applications, found typically in schools (K-12), utilising higher resolution video projectors and VCR/laser disk players. The 386S Adapter is connected to the building wiring at an information outlet (IO) in the work area and can be mounted with an 811A Panel (optional) located in the telecommunications closet (TC). The 386S Adapter can be mounted in the work location using either the adhesive-backed velcro strip(s) or screw tab holes provided with the product. The 811A Panel can hold up to six 386S Adapters in an EIA-310 48.3cm (19in) rack. Phono plug cables and S-Video cables must be obtained locally and are not provided with the 386S Adapter. The proper cord must also be used for the cable type. Workstation or Modular Patch Cords may be used with 1010/2010 cable. However, only use the Modular Patch Cord with 1061/2061 and 1071/2071 cables to ensure the operational distances.
ADAPTERS
OPERATIONAL DISTANCES
224
Cable Type
Distance
1010/2010
365m (1200ft)
1061/2061/1071/2071
547m (1500ft)
Product
Comcode
Packaging
386S
108544487
1/Pkg
Adapters Contents Page
ADAPTERS
Copper
ISDN
Transmission
110 RA2-12 Terminating Resistor Block
Adapters Contents Page
The 110RA2-12 Terminating Resistor Block provides the standard 100-ohm circuit termination used on Integrated Listed
Services Digital Network (ISDN) Basic Rate Interface (BRI) circuits. The Terminating Resistor Block consists of 110D-4 connecting blocks and a resistor/capacitor circuit that is soldered to a printed wiring board mounted on an Avaya 110AW2 Wiring Block. The circuit consists of a 100-ohm resistor and DC-blocking capacitor in series across adjacent pairs of 110 Terminal Blocks. Each 110RA2-12 Terminating
Figure 152
Resistor Block provides twelve 2-pair circuit terminations
110RA2-12 ISDN
and provides two output rows for use with point-to-multi-
Terminating
point as well as point-to-point configurations. The block
Resistor Block
comes with designation labels and holders to provide circuit identification. The termination circuit conforms to both ANSI and CCITT ISDN standards. The 110RA2-12 Terminating Resistor Block provides the standard 100-ohm circuit termination used on Integrated Services Digital Network (ISDN) Basic Rate Interface (BRI) circuits. The Terminating Resistor Block consists of 110D-4 connecting blocks and a resistor/capacitor circuit that is soldered to a printed wiring board mounted on an Avaya 110AW2 Wiring Block. The circuit consists of a 100-ohm resistor and DCblocking capacitor in a series across adjacent pairs of 110 Terminal Blocks. Each 110RA2-12 Terminating Resistor Block provides twelve 2-pair circuit terminations and provides two output rows for use with point-to-multipoint as well as point-to-point configurations. The block comes with designation labels and holders to provide circuit identification. The termination circuit conforms to both ANSI and CCITT ISDN standards.
ADAPTERS
Physical Specifications Height: 9.12cm
Weight: 380 g
Width: 27.23cm
Temperature: 0 to 60ºC
Depth: 8.25cm
Humidity: 5-95% (noncondensing)
Input: 12x 2-pair ISDN BRI Output: 24x 2-pair ISDN BRI (12x 2-terminal multipoint configuration)
Electrical Specifications Termination Resistance: 100 Ω ± 5%
Product
Comcode
Circuit Size
Packaging
110RA2-12
107059875
12-2pr
1/Pkg
225
ADAPTERS
Copper
ISDN
Transmission
440A4 ISDN Terminating Resistor Adapter
Adapters Contents Page
The 440A4 ISDN Terminating Resistor Adapter provides the standard 100-ohms circuit termination used on Integrated Services Digital Network (ISDN) Basic Rate Interface (BRI) circuits. The adapter consists of a resistor/ capacitor circuit enclosed in a flame-retardant plastic housing. The circuit consists of a 100-ohms resistor and DC-blocking capacitor in series across the first and third circuit pairs. The capacitor provides robust protection for the resistor against accidental Figure 153
connections to AC/DC power crosses, as well as analogue
440A4
voice and ringing circuits.
Terminating Resistor
The 440A4 Adapter has an RJ45 modular plug at one end
Adapter
and an RJ45 modular jack at the other. The modular plug is attached to a short length of cordage for easier installation. The adapter is typically installed between the information outlet and the ISDN terminal, and can be used for both point-to-point and passive bus wire arrangements. The termination circuit conforms to both ANSI and CCITT Listed
ISDN standards. The 440A4 is UL Listed.
Physical Specifications Length (with cord): 43.8cm
Weight: 48.2 g
Temperature: 0 to 60ºC
Humidity: 5-95% (noncondensing)
Electrical Specifications
ADAPTERS
Termination Resistance: 100 Ω ± 5%
226
Product
Comcode
Ports
Packaging
440A4
105197784
RJ45 Jack To RJ45 Plug
1/Pkg
Protectors Chapter
7
227
Protectors Contents
Click Here Main Menu
Copper PANELS Small Pair Count - 110ANA1 229 489 A&B Models
230
UNITS 4B1-EW & 4C3S-75
228
Protector Units
231
Category 5 OSP Protector
233
PROTECTORS
Copper
Small Pair Count 110ANA1
Panels
110ANA1 Protector Panel
Protectors Contents Page
The 110ANA1 Multipair Protector Panel provides indoor station protection for small-pair-count applications using the 3B, 3C, 4B, or 4C Series Protector Units. The unique internal wiring design prevents protector bypass. Designed with 110-Type connecting blocks for input and output terminations, the 110ANA1 Multipair Protector Panel provides a modular, space-efficient package with quiet-front and simplified installation directly on the wall. The individual protector modules should be ordered Figure 154
separately. The 110ANA1 Multipair Protector Panel is Listed
110ANA1
UL Listed.
Protector Panel
Physical Specifications Height: 25.4cm Width: 9.9cm Depth: 6.6cm
Product
Comcode
Pair Size
Packaging
110ANA1-25
105736490
25
1/Pkg
PROTECTORS 229
PROTECTORS
Copper
489 A&B Models
Panels
Building Entrance Protector
Protectors Contents Page
The 489 Type Multipair Protector Panel provides protection for communication equipment and circuits exposed to voltage surges and sneak currents. The protector panel, designed for use with the 110 Connector System, consists of a plastic housing containing mountings for 3B, 3C, 4B or 4C Series Protector Units (sold separately). The 489A replaces the 188-Type equipped with 110-Type connecting blocks and the 489B replaces the 189-Type equipped with the 66-Type connecting block.
Listed
Input options for the protector panel include a swivel input stub and splice chamber equipped with a 110 Wiring Block or 710 or 3M connector. Both input options allow cable to be fed from the top or bottom. The conductors in the swivel stub and splice chamber are 26 AWG and satisfy the fuse link requirements. Insertion of the protector units into the protector panel complete the circuit to the 110 Connector System termination field output.
Figure 155 489 A&B Building Entrance Protector
Physical Specifications Height: 31.4cm
Depth: 13.4cm
PROTECTORS
Width: 38.2cm
230
Product
Comcode
Description
Block Type
Pair Size
Packaging
489BCCI-025
107895138
Swivel Stub
66 Block
25
1/Pkg
489BCCI-050
107895146
Swivel Stub
66 Block
50
1/Pkg
489BCCI-100
107895153
Swivel Stub
66 Block
100
1/Pkg
489BCBI-025
107895096
66 Block
66 Block
25
1/Pkg
489BCBI-100
107895112
66 Block
66 Block
100
1/Pkg
489BCSI-025
107895203
710 Connector
66 Block
25
1/Pkg
489BCSI-100
107895229
710 Connector
66 Block
100
1/Pkg
489BCSI-050
107895211
710 Connector
66 Block
50
1/Pkg
489ACAI-050
107894917
110 Connector
66 Block
50
1/Pkg
489ACAI-100
107894925
110 Connector
66 Block
100
1/Pkg
489BCBI-050
107895104
66 Block
66 Block
50
1/Pkg
489ACCI-025
107894941
Swivel Stub
110 Connector
25
1/Pkg
489ACCI-050
107894958
Swivel Stub
110 Connector
50
1/Pkg
489ACCI-100
107894966
Swivel Stub
110 Connector
100
1/Pkg
489ACAI-025
107894909
110 Connector
110 Connector
25
1/Pkg
489ACMI-025
107894974
3M Connector
110 Connector
25
1/Pkg
489ACMI-050
107894982
3M Connector
110 Connector
50
1/Pkg
489ACSI-025
107895039
710 Connector
110 Connector
25
1/Pkg
489ACSI-050
107895047
710 Connector
110 Connector
50
1/Pkg
489ACSI-100
107895070
710 Connector
110 Connector
100
1/Pkg
489BCMI-025
107895161
3M Connector
66 Block
25
1/Pkg
489BCMI-050
107895179
3M Connector
66 Block
50
1/Pkg
489BCMI-100
107895187
3M Connector
66 Block
100
1/Pkg
PROTECTORS
Copper
4B1-EW and 4C3S-75 Protector Units
Units
Surge Arrester
Protectors Contents Page
SYSTIMAX SCS Surge Arresters are UL-listed five-pin ®
devices that plug into the 110-ANA1 and 489-Type Multipair Protector Panels. Each unit is moulded to glassreinforced, high-heat-distortion plastic (polybutylene terephthalate). Line pins are gold-plated for long-term, reliable performance and ground pins are solder-plated. The 3B1-EW and 4B1-EW Gas-Tube Protector Units are 31-RL wide-gap, gas-tube surge arresters that provide overvoltage protection. The service life of these wide-gap gas tubes exceeds that of other gas-tube protectors. The 4B1-EW includes heat coils for sneak current protection.
Figure 156 4B1-EW Protector Unit
The 3C1S and 4C1S Solid-State Protector Units offer a solid-state alternative to gas-tube protectors. Solid-state protectors provide precision overvoltage protection for more sensitive circuits, and offer unlimited service life as long as the maximum rated impulse discharge current (200 amps) is not exceeded. The 4C1S includes heat coils for sneak current protection. The 4C3S-75 Protector Unit is a solid-state protector for use on circuits which do not normally experience ringing voltages Listed
and also includes heat coils for sneak current protection.
Physical Specifications 4B1-EW
4C3S-75
Height: 5.0cm
Operational Temperature Range: -40 to 65ºC
Width: 1.9cm
Pair Size: 1-pair
Depth: 1.3cm
PROTECTORS
Electrical Specifications 4C3S-75 DC Breakdown Voltage @ 2kV/sec: 60-90 V Surge Breakdown Voltage @100 V /µsec: 220-300 V Insulation Resistance (PE-80): > 100 M Ω DC Holdover Current: 260 mA/52 V On-State Voltage @ 75 A: < 10 V Response Time: < 100 nsec Rated Impulse Discharge: 100 A Capacitance(VDC=50 V, f=1 kHz, V AC=1 Vrms): < 100pF Line Series Resistance: < 4 Ω Sneak Current Operation (heat coils): 540 mA <210 sec, 1 A <15 sec
231
PROTECTORS
Copper
4B1-EW and 4C3S-75 Protector Units
Units
Surge Arrester (contd)
Electrical Specifications (contd) 4B1-EW DC Breakdown Voltage @ 2 kV/sec: 265-425 V Surge Breakdown Voltage @ 100 V/µsec: 200-800 V Insulation Resistance (PE-80): 100 MΩ Typical DC Holdover Current (ANSI C62.31): 150 V Typical Vented Breakdown Voltage (surpasses UL requirements): <1000 V DC Arc Voltage: 20 V Typical Glow-to-Arc Transition Current (ANSI C62.31): 0.5 A Typical Capacitance (PE-80): 10 pF AC Discharge (PE-80): 65 A (11 cycles @ 60 Hz) Max. Impulse Discharge (PE-80): 20 kA (8x 20 µsec waveform) Sneak Current Operation (heat coils @ 20ºC): 540 mA: <210 sec; 1A: <15 sec Service Life Characteristics: 1 sec. 1 A AC Burst @ 60 Hz: >60 operations 1 sec. 10 A AC Burst @ 60 Hz: >20 operations Continuous 0.5 A AC @ 60 Hz: 140 sec. 10 A Surges (10x 1 msec waveform): >1000 operations 100 A Surges (10x 1 msec waveform): >100 operations 300 A Surges (10x 1 msec waveform): >50 operations For the stated number of operations, VB, VL and RL values remain within required ranges as follows: VB: 265-425 V, VL: <1000V and RL: >10 MΩ
PROTECTORS
Product
232
Comcode
Description
Application
Packaging
Colour
3B1-EW
104410147
Gas-tube (wide gap)
Standard Service
1/Pkg
Black
3C1S
105514756
Solid-state
Standard Service
1/Pkg
Black
4C1S
104386545
Solid-state w/heat coils
Standard Service
1/Pkg
Black
4C3S-75
105581086
Solid-state (75V nominal) w/heat coils
Nonringing
1/Pkg circuits
Red
4B1-EW
104401856
Gas-tube (wide gap) w/heat coils
Standard Service
1/Pkg
Black
Protectors Contents Page
PROTECTORS
Copper
Category 5 OSP Protector
Units
Protector
Protectors Contents Page
The CAT 5 OSP Protector unit is designed to give protection for data circuits entering the building. Each unit protects a 4-pair (8-wire) circuit. When this protector is used with Avaya’s Category 5 OSP Cable and Power Sum Components for a complete end-to-end installation, they form a Certified SYSTIMAX SCS installation. This solid state device protects sensitive network equipment from damage caused by transient voltage surges. UL 497 Listed, this primary protector serves high performance OSP
Figure 157
cable between buildings and remote workstations, as well
Category 5 OSP Protector
as, hostile industrial environments within buildings. In order to protect data circuits, this protector meets the electrical specifications of Commercial Building Telecommunications Cabling Standard ANSI/TIA/EIA-568-A. Listed
Not for use with voice applications over the CAT 5 OSP cable.
Physical Specifications Height: 10.8cm Depth: 3.6cm Width: 10.8cm
Electrical Specifications Protector Type: 100% Solid State Clamping Voltage: 16 VAC, nominal Maximum Response Time: 2 - 5 nanoseconds Grounding Requirements:10 AWG for primary or 10 AWG for isolated Loop Applications Grounding Connection: 8-32 screw to ground plate module
Comcode
Pair Size
Packaging
C5P4T-16
108224874
4
1/Pkg
PROTECTORS
Product
233
234
To o l s Chapter
8
235
To o l s Contents
Click Here Main Menu
Copper COPPER Termination Tools
237
Fibre FIBRE Connector Termination Tool Kit
238
Splice Tool Kit
245
CONSUMABLES
236
Kits
246
Supplies
256
TOOLS
Copper
Termination Tools
Copper
Impact & Retention Tools
Tools Contents Page
There are several tools which can be used for terminating copper conductors on the Avaya 110 Connector System. The D-914 Impact Tool is used for hard-wire terminations (one at a time) on 110C Connecting Blocks. It consists of a plastic handle with a metal head. The adjustment switch on the handle is labelled HI for 22-AWG or larger conductors and LO for 24 or 26-AWG conductors. The D-914 Impact Tool is red and “CUT” is labelled on the cut side.
Figure 158 788H1 Impact Tool,
The D-914 uses a 110 Reversible Blade that inserts, or
788K1 Wire Retention
inserts and cuts off one conductor. In addition to the
Tool, D-914 Impact Tool &
built-in blade storage compartment and impact adjustment
788M2 Head
control, the D-914 handle has a spudger, wire picker and screwdriver bit. The 788H1 Impact Tool consists of a metal spring loaded handle with metal head housing a reversible insert (one side of the insert is for terminate only and the other side is for terminate & trim). The handle is fitted with a rubber grip for better gripping and comfort. The 788H1 is used for terminating or terminating & trimming ten conductors at a time. It is also used for seating the 110C Connecting Block onto the 110 Wiring Block. The 788M2 Replacement Head
Figure 159
can be ordered separately.
D-914 Impact Tool
The 788K1 Wire Retention Tool is used as an aid in holding down cable conductors when removing 110C Connecting Blocks from the 110 Wiring Block. The KS-22035-L2 (commonly known as the “Spudger”) is a small pencil shaped tool with a sharp, pointed Lshaped metal pick used to lift and remove small pieces of conductor insulation caught in the 110-type Wiring Block
TOOLS
or between the plastic teeth of the 110C Connecting Block.
Product
Comcode
Description
Packaging
8762D Kit
406477794
Impact Tool (Handle + Blade), 1 cond.
1/Pkg
D-914 Impact Tool
407484971
Impact Tool (handle only), 1 cond.
1/Pkg
M110 Blade
407728427
Replacement Blade for the 8762D Impact Tool
1/Pkg
788H1 Tool
108062043
Impact Tool (Handle + Blade), 10 cond.
1/Pkg
788M2 Head
107975864
Replacement Head for the 788H1 Impact Tool
1/Pkg
788 KIT
407732585
Replacement Blades
1/Pkg
788K1 Tool
102655495
Wire Retention Tool
1/Pkg
KS-22035-L2
405423260
Spudger
1/Pkg
237
TOOLS
Fibre
Connector Termination Tool Kit
Fibre
QwikCrimp™ Tool Kit
TOOLS
The QwikCrimp Tool Kit is an easy to use tool kit for fibre termination.
238
Product
Comcode
1032K
108640319
1032J
108313685
D-183033
108641853
Kit Quantity
Description
Replacement Comcode
1
QwikCrimp LC Assembly Tool
Unable to order individually
1
Fiber Stripper, No-Nik®
Unable to order individually
1
Fibre Stripper, Micro-Strip®
Unable to order individually
1
Fiber Cleaver, Score & Snap
Unable to order individually
1
Microscope Assembly
Unable to order individually
1
Instruction Sheets
Unable to order individually
1
Additional Miscellaneous Tools
Unable to order individually
Tools Contents Page
TOOLS
Fibre
Connector Termination Tool Kit
Fibre
1032F1 - Tool Kit
Tools Contents Page
The 1032F1 Tool Kit contains all the tools needed to field mount ST, STII, STII+ and SC fibre connectors on 3.0 mm cordage and on 900 micron buffered fibre using the EZ method. A 102A Crimping Tool (Comcode: 700008253) can be ordered separately to allow installation of ST or STII connectors on 3.0 mm cordage. This kit can also be used to mount connectors using the epoxy method if a 200A1 220V Comcode: (700008048) Curing Oven is ordered. Figure 160 1032F1 Fibre Connector
Connectors and consumable kits must be ordered separately.
Tool Kit
Product
Comcode
1032F1 KIT
700005929
Kit Quantity
Description
1
Replacement Quantity
1510B Crimping Tool
700008220
1
1
300B Microscope
Unable to order individually
1
1510A Polishing Tool
700008238
1
12
600B Connector Holders
700005143
1
1
700A Stripping Tool
700008261
1
1
1026A Heat Strip Tool
Unable to order individually
2
971A-1 Holder Blocks
Unable to order individually
1
975A Cleaving Tool
700008287
1
1
Scissors
700008022
2
1
6-inch Scale
700008030
5
1
Alcohol Bottle
Unable to order individually
1
Glass Plate
Unable to order individually
1
Stripping Tool (R4366)
7000011158
1
Instruction Manual
Unable to order individually
TOOLS
Comcode
1
15
Micro Clips (1043A)
Unable to order individually
12
SC Curing Fixtures
700008212
2
Modified SM/MM SC Grips
Unable to order individually
1
ST II+ EZ Instruction Sheet
Unable to order individually
1
SC EZ Instruction Sheet
Unable to order individually
1
Rubber Polishing Pad
700005564
10
1
1039B Cut Length Template
700008204
5
12
239
TOOLS
Fibre
Connector Termination Tool Kit
Fibre
1032B6 - Tool Kit
The 1032B6 Tool Kit contains tools needed to field mount ST, STII, STII+ and SC fibre connectors on 3.0 mm cordage and on 900 micron buffered fibre using the epoxy method or EZ method (depending on the consumables ordered). This tool kit comes with the 200A1 Curing Oven (220V).
TOOLS
Connectors and consumable kits must be ordered separately.
240
Product
Comcode
1032B6 KIT
700005960
Kit Quantity
Description
Replacement
1 1 1
1510A Polishing Tool
700008238*
1
12
600B Connector Holders
700005143*
12
1
700A Stripping Tool
700008261*
1
1
1026A Heat Strip Tool
Unable to order individually
2
971A-1 Holder Blocks
Unable to order individually
1
975A Cleaving Tool
700008287
1
1
Scissors
700008022
2
1
6-inch Scale
700008030
5
1
Alcohol Bottle
Unable to order individually
1
Glass Plate
Unable to order individually
1
Stripping Tool (R4366)
700011158
1
Instruction Manual
Unable to order individually
15
Micro Clips (1043A)
Unable to order individually
1
200A1 Curing Oven
700008048
1
12
SC Curing Fixtures
700008212
12
2
Modified SM/MM SC Grips
Unable to order individually
1
ST II+ Epoxy Instruction Sheet
Unable to order individually
1
ST II+ EZ Instruction Sheet
Unable to order individually
1
SC Epoxy Instruction Sheet
Unable to order individually
1
SC EZ Instruction Sheet
Unable to order individually
1
Rubber Polishing Pad
700005564
10
1
1039B Cut-length Template
700008204
5
Comcode
Quantity
1510B Crimping Tool
700008220*
1
300B Microscope
Unable to order individually
1
Tools Contents Page
TOOLS
Fibre
Connector Termination Tool Kit
Fibre
1032H - Tool Kit
Tools Contents Page
The 1032H Mini Tool Kit is intended for connectorisation of buffered fibre with LC, SC, and ST multimode or singlemode connectors using the anaerobic method. The kit does not contain the crimp tool for cordage connectorisation.
Product
Comcode
1032H KIT
700005838
Kit Quantity
Description
Replacement
1
Glass Polishing Plate
Unable to order individually
1
300B Microscope
Unable to order individually
1
Rubber Polishing Pad
700005564
1
ST/SC Microscope Adapter
Unable to order individually
1
Stripping Tool (R4366)
700011158
1
1
1039B Cut-length Template
700008204
5
2
1510A1 Polishing Tools (ST/SC)
700008238
1
2
T2001A1 Polishing Tools (LC)
700008170
1
12
600B1 Connector Holders (ST)
700005143
12
12
1510C Connector Holders (SC)
700008212
12
12
LC Connector Holders
700005135
12
1
975A Cleaving Tool
700008287
1
1
Scissors
700008022
2
1
5x Eye Loupe
Unable to order individually
Comcode
15
1043A Micro Clips
Unable to order individually
1 ea.
LC/ST/SC Instructions
Unable to order individually
1
700A Stripping Tool
700008261
Quantity
10
1
TOOLS 241
TOOLS
Fibre
Connector Termination Tool Kit
Fibre
D-182737 Upgrade Kit
This upgrade kit, when added to the 1032B, 1032B1 or 1032F Tool Kit, provides the necessary tools and
TOOLS
instructions to field-assembly STII+ and SC multimode or singlemode connectors on 3.0 mm cordage.
242
Product
Comcode
D-182737 KIT
700005952
Kit Quantity
Description
1
Replacement Comcode
Quantity
1510B Crimping Tool
700008220
1
12
600B ST Connector Holders
700005143
12
1
1039B Cut-length Template
700008204
5
12
1510C Curing Fixtures
700008212
12
1
Universal Microscope Adapter
Unable to order individually
1
1510A Polishing Tool
700008238
1
1
Rubber Polishing Pad
700005564
10
1
STII+ Epoxy Instruction Sheet
Unable to order individually
1
STII+ EZ Instruction Sheet
Unable to order individually
1
SC Epoxy Instruction Sheet
Unable to order individually
1
SC EZ Instruction Sheet
Unable to order individually
2
Modified SM/MM SC Grips
Unable to order individually
Tools Contents Page
TOOLS
Fibre
Connector Termination Tool Kit
Fibre
D-182905 Upgrade Kit
Tools Contents Page
This upgrade kit, when added to the 1032B, 1032B1 or 1032F Tool Kit, provides the necessary tools and instructions to field-assembly LC multimode or singlemode connectors on 0.9 µm cordage.
Product
Comcode
D-182905 KIT
700005895
Kit Quantity
Description
1 1
Replacement Comcode
Quantity
LC Polishing Fixture
700008196
1
LC Microscope w/adapter
700005887
1
12
LC Connector Holder
700005135
12
1
Plastic Polishing Pad
Unable to order individually
1
Instruction Sheet
Unable to order individually
TOOLS 243
TOOLS
Fibre
Connector Termination Tool Kit
Fibre
D-182959 Upgrade Kit
The D-182959 Tool Upgrade Kit for LC connectors provides the tools such as crimp jaws, heater pipes, and a polishing puck to terminate the LC connector onto either 900 micron buffered fibre or 1.6 mm
TOOLS
cordage. The D-182959 Kit is to be used in concert with the 1032B6 and 1032F1 Tool Kits.
244
Product
Comcode
D-182959 KIT
700005853
Kit Quantity
Description
1
Replacement Comcode
Quantity
T2001A Polishing Tool
700008170
1
1
LC Microscope
700005887
1
12
LC BTW Connector Holders
700005135
12
12
LC Jumper Connector Holders
700005846
12
1
971A-2 Holder Block
700008139
1
1
LC Cut Length Template
700007974
5
1
LC Instructions
Unable to order individually
1
1510LC Crimping Tool
700008154
1
1
LC Stripper Guide Tube for 1026A
700008147
1
1
Ultra-Fine-Point Permanent Pen
Unable to order individually
6
Heat Tube Assemblies
700002330
6
1
C1001B-2 Multimode LC Adapter
700002355
1
Tools Contents Page
TOOLS
Fibre
Splice Tool Kit
Fibre
1048B Tool Kit
Tools Contents Page
The 1048B Tool Kit contains tools needed to assemble a splice. This kit comes with a hand-held model workstation. The CSL splices and Cleaver must be ordered separately.
Figure 161 1048B Fibre Splice Tool Kit
Product
Comcode
1048B KIT
106630833
Description
Replacement
1
1041B Handheld Workstation
1
1046B Re-entry Tool
Unable to order individually
1
1504B Buffer Retention Tool
106630825
1
Wire Stripper
Unable to order individually
1
Micro Stripper (0.006"") (152.4 mm)
Unable to order individually
1
Alcohol Bottle
Unable to order individually
1
5X Eye Loupe
Unable to order individually
1
Spudger
Unable to order individually
1
Tweezers
Unable to order individually
1
Brush
Unable to order individually
1
Safety Glasses
Unable to order individually
1
Workstation Light
Unable to order individually
1
Instruction Manual
Unable to order individually
1
Instructional Video
Unable to order individually
1
Tool Case
Unable to order individually
Comcode
Quantity
106485113
1
1
TOOLS
Kit Quantity
245
TOOLS
Fibre
Kits
Consumables
STII Consumables Epoxy Method
Tools Contents Page
This D-Kit contains supplies to field-assemble approximately 100 enhanced multimode STII Connectors on jumper cordage, fibre cable or direct termination on outside plant cable fibres using the epoxy method. The kit does not include alcohol, compressed air or connectors. This kit is used with the 1032B Tool Kit.
Figure 162 D-182038 Consumable Kit
Product
Comcode
D-182038 KIT
105501415
TOOLS
Kit Quantity
246
Description
Replacement Comcode
Quantity
2 Pkgs.
Wipes
Unable to order individually
1 Vial
Music Wire
700008394
1 Pkg.
Syringes
Unable to order individually
1 Pkg.
Dispensing Tips
Unable to order individually
15 Pkgs.
Epoxy
700006109
15 Pkgs.
25 Sheets
Type A Polishing Paper
700006737
100 Sheets
25 Sheets
Type B Polishing Paper
Unable to order individually
4 Vials
TOOLS
Fibre
Kits
Consumables
STII Consumables EZ Method
Tools Contents Page
The D-182709 Consumable Kit contains supplies to mount approximately 500 multimode ST or STII connectors using the EZ method (with the 1032F-type tool kit). The kit includes the primer and adhesive, but does not contain alcohol, compressed air, or connectors.
Product
Comcode
D-182709 KIT
106736937
Kit Quantity
Description
Replacement
10 Pkgs.
Wipes
Unable to order individually
5 Vials
Music Wire
700008394
125 Tips
Dispensing Tips
Unable to order individually
2 Bottles
Adhesive
700002181
1 Bottle
2 Bottles
Primer
700004146
1 Bottle
125 Sheets
Type A Polishing Paper
700006737
100 Sheets
125 Sheets
Type C Polishing Paper
Unable to order individually
2 Copies
Instruction Sheet
Unable to order individually
Comcode
Quantity
4 Vials
TOOLS 247
TOOLS
Fibre
Kits
Consumables
STII+/SC/LC Consumables - Epoxy Method This D-182738 Consumables Kit contains supplies to field-assemble 100 multimode SC, STII or STII+ connectors with pre-radiused zirconia ferrules using heat cured epoxy or approximately 200 multimode LC connectors. Connectors are ordered separately. This kit is the same as the D-182739 Kit except Type E
TOOLS
Polishing Paper is not provided. This kit does not contain alcohol, compressed air or connectors.
248
Product
Comcode
D-182738 KIT
106919236
Kit Quantity
Description
Replacement
2 pkgs.
Wipes
Unable to order individually
1 Vial
Music Wire
700008394
15 Syringes
Syringes
Unable to order individually
25 Tips
Dispensing Tips
Unable to order individually
1 Pkg.
Epoxy
700006109
15 Packs
2 Sheets
Type F Polishing Paper
700006703
10 Sheets
25 Sheets
Type A Polishing Paper
700006737
100 Sheets
25 Sheets
Type D Polishing Paper
Unable to order individually
1 Pkg
Pipe Cleaners
Unable to order individually
Comcode
Quantity
4 Vials
Tools Contents Page
TOOLS
Fibre
Kits
Consumables
STII+/SC/LC Consumables - EZ Method
Tools Contents Page
The D-182804 Consumable Kit contains supplies to mount approximately 500 multimode SC or STII+ (also ST & STII with a zirconia ferrule) connector plugs using the EZ method (with the 1032F-type tool kit). Alternatively it can terminate up to 1000 LC connectors (using the 1032F1 tool kit with the D-182905 upgrade kit (107852139). The kit includes the primer and adhesive, but does not contain alcohol, compressed air, or connectors.
Product
Comcode
D-182804 KIT
107148942
Kit Quantity
Description
Replacement Comcode
10 Pkgs.
Wipes
Unable to order individually
5 Vials
Music Wire
700008394
75 Syringes
Syringes
Unable to order individually
125 Tips
Dispensing Tips
Unable to order individually
2 Bottles
Adhesive
700002181
Quantity
4 Vials
1 Bottle
2 Bottles
Primer
700004146
1 Bottle
1 Sheet
Type F Polishing Paper
700006703
10 Sheets
2 Copies
Instruction Sheet (STII)
Unable to order individually
2 Copies
Instruction Sheet (STII+)
Unable to order individually
2 Copies
Instruction Sheet (SC)
Unable to order individually
125 Sheets
Type G Polishing Paper
Unable to order individually
50 Sheets
Paper Polishing Pad
Unable to order individually
2 Bottle
Loctite Super Bonder 495
Unable to order individually
25 Sheets
Type A Polishing Paper
700006737
25 Sheets
TOOLS 249
TOOLS
Fibre
Kits
Consumables
D-182720 Kit
Tools Contents Page
This D-182720 Consumables Kit contains supplies to field-assemble approximately 100 singlemode SC, STII, STII+ Connectors with pre-radiused zirconia ferrules using EZ adhesive on cordage, Outside Plant
TOOLS
(OSP) cable, or approximately 200 singlemode LC connectors. Connectors are ordered separately.
250
Product
Comcode
D-182720 KIT
700005630
Kit Quantity
Description
1 Vials
Replacement Comcode
Quantity
Music Wire
700008394
4 Vials
1 Bottles
Adhesive
700002181
1 Bottle
1 Bottles
Primer
700004146
1 Bottle
2 Sheets
Type F Polishing Paper
700006703
10 Sheets
1 Copy
Instruction Sheet (STII)
Unable to order individually
1 Copy
Instruction Sheet (STII+)
Unable to order individually
1 Bottle
Loctite Super Bonder 495
Unable to order individually
1 Copy
Instruction Sheet (SCI)
Unable to order individually
1 Sheet
Type A Polishing Paper
700006737
25 Sheets
TOOLS
Fibre
Kits
Consumables
D-182739 Kit
Tools Contents Page
This D-Kit contains supplies to field-assemble approximately 100 singlemode SC, STII or STII+ connectors with zirconia ferrules using heat cured epoxy on jumper cordage cable, or direct termination or approximately 200 singlemode LC connectors. (Connectors are ordered separately.)
Product
Comcode
D-182739 KIT
700005622
Kit Quantity
Description
Replacement
1 Vials
Music Wire
1 Pkg.
Epoxy
700006109
15 Pkgs.
2 Sheets
Type F Polishing Paper
700006703
10 Sheets
25 Sheets
Type A Polishing Paper
700006737
100 Sheets
10
Pipe Cleaners
Unable to order individually
Comcode
Quantity
700008394
4 Vials
TOOLS 251
TOOLS
Fibre
Kits
Consumables
D-182918 Kit
Tools Contents Page
The D-182918 Kit contains consumables to terminate 1.6mm Cordage with STII+ Fibre Optic Connectors. The connectors, consumable kits and the 500B insertion tool must also be ordered.
Product
Comcode
D-182918 KIT
700005879
Kit Quantity
Description
1
Instruction Manual
Unable to order individually
100
Sheath Tubes
Unable to order individually
100
Crimp Sleeves (STII+)
Unable to order individually
Fibre
Replacement Comcode
Kits
Quantity
Consumables
D-182919 Kit The D-182919 Kit contains consumables to terminate 1.6mm Cordage with SC Fibre Optic Connectors.
TOOLS
The connectors, consumable kits and the 500B insertion tool must also be ordered.
252
Product
Comcode
D-182919 KIT
700005861
Kit Quantity
Description
Replacement
1
Instruction Manual
Unable to order individually
100
Sheath Tubes
Unable to order individually
100
Crimp Sleeves (SC)
Unable to order individually
Comcode
Quantity
TOOLS
Fibre
Kits
Consumables
LC Consumables Multimode
Tools Contents Page
The D-182983 Consumable Kit contains supplies to mount approximately 200 multimode LC connector plugs using the heat-cured epoxy method.
Product
Comcode
D-182983 KIT
108340811
Kit Quantity
Description
2 Pkgs.
Replacement Comcode
Quantity
Wipes
Unable to order individually
250 Sheets
1 Vials
Music Wire
700008394
4 Vials
15 Syringes
Syringes
Unable to order individually
10 Syringes
25 Tips
Dispensing Tips
Unable to order individually
125 Tips
1 Pkg
Adhesive
700002181
15/Pkg
10 Sheets
Clear Spacers
Unable to order individually
10 Sheets
Foam Pad (white)
Unable to order individually
20 Sheet
Type J Polishing Paper (purple)
700006661
20 Sheets
5 Sheets
Type F Polishing Paper (yellow)
700006695
5 Sheets
6 Brushes
LC Adapter Brush
Unable to order individually
TOOLS 253
TOOLS
Fibre
Kits
Consumables
LC Consumables Multimode The D-182984 Consumable Kit contains supplies to mount approximately 100 multimode LC connectors using anaerobic EZ adhesive. The kit includes the primer and adhesive, but does not contain alcohol, compressed air or connectors.
Product
Comcode
D-182984 KIT
108340829
TOOLS
Kit Quantity
254
Description
Replacement Comcode
Quantity
100 Sheets
Wipes
Unable to order individually
1 Vial
Music Wire
700008394
15 Syringes
Syringes
Unable to order individually
25 Tips
Dispensing Tips
Unable to order individually
10 Sheets
Clear Spacers
Unable to order individually
10 Sheets
Foam Pad (white)
Unable to order individually
20 Sheets
Type J Polishing Paper (purple)
700006661
20 Sheets
5 Sheets
Type F Polishing Paper (yellow)
700006695
5 Sheets
6 Brushes
LC Adapter Brush
Unable to order individually
1 Bottle
Adhesive
700002181
1 Bottle
1 Bottle
Primer
700004146
1 Bottle
4 Vials
Tools Contents Page
TOOLS
Fibre
Kits
Consumables
LC Consumables Singlemode
Tools Contents Page
The D-182985 Consumable Kit contains supplies to mount approximately 200 singlemode LC connector plugs using anaerobic EZ adhesive. The kit includes the primer and adhesive, but does not contain alcohol, compressed air, or connectors.
Product
Comcode
D-182985 KIT
700005309
Kit Quantity
Description
Replacement Comcode
Quantity
100 Sheets
Wipes
Unable to order individually
1 Vial
Music Wire
700008394
15 Syringes
Syringes
Unable to order individually
25 Tips
Dispensing Tips
Unable to order individually
10 Sheets
Clear Spacers
Unable to order individually
10 Sheets
Foam Pad (white)
Unable to order individually
20 Sheet
Type J Polishing Paper (purple)
700006661
20 Sheets
5 Sheets
Type F Polishing Paper (yellow)
700006695
5 Sheets
5 Sheets
Type K Polishing Paper (grey)
700008063
4 Vials
10 Sheets
Type L Polishing Felt (purple)
Unable to order individually
6 Brushes
LC Adapter Brush
Unable to order individually
1 Bottle
Adhesive
700002181
1 Bottle
1 Bottle
Primer
700004146
1 Bottle
TOOLS 255
TOOLS
Fibre
Supplies
Consumables
Adhesive and Primer
Tools Contents Page
The Primer and Adhesive are consumables used with the 1032-type Fibre Connector Tool Kit using the EZ method. The Primer and Adhesive are used together, and when mixed in an air-tight environment, the mixture solidifies. Specifically, these compounds are used in an LC, ST or SC fibre connector to secure the fibre and keep it from moving within the connector ferrule. One bottle is sufficient to terminate 250 connectors.
Product
Comcode
Packaging
ADHESIVE
700002181
1/Pkg
PRIMER
700004146
1/Pkg
Fibre
Supplies
Consumables
Epoxy The Epoxy is a consumable used with the 1032B-type Fibre Connector Tool Kit which comes equipped with a curing oven. The Epoxy consists of two compounds that, when mixed, eventually solidify. Heating the Epoxy mixture allows it to solidify much quicker as it hardens during the cooling process. The Epoxy is injected into an ST or SC fibre connector, the fibre is then inserted and placed in the curing oven. The Epoxy secures the fibre within the connector and provides extra protection to the fibre end
TOOLS
during the polishing process. The kit provides 8-gram, 2-part Epoxy packages.
256
Product
Comcode
Packaging
EPOXY
700006109
15/Pkg
Tools Contents Page
TOOLS
Fibre
Supplies
Consumables
Type A Polishing Paper
Tools Contents Page
The Type A-Polishing Paper is a consumable used with the 1032B-type Fibre Connector Tool Kit. It is a foam-backed polishing paper used for the first polishing process when connectorising fibres with the epoxy method. Product
Comcode
Packaging
TYPE A
700006737
100/Pkg
TOOLS 257
258
Miscellaneous Chapter
9
259
Miscellaneous Contents
Click Here Main Menu
Copper CLAMPS B-Bond Clamp
261
Fibre CLAMPS Cable Clamps
262
CONSUMABLES Buffer Tubing Kit
263
Splitter Kit
264
SPLICING Cleave Sleeve & Leave
266
TESTING 4-Pair Tester
260
267
MISCELLANEOUS
Copper
B-Bond Clamp
Clamps
B-Bond Clamp
Misc. Contents Page
The B-Bond Clamp is used to make an electrical bond to the aluminium sheath of the mechanically armoured riser cables with an outside diameter up to 2 cm. The clamp can then be connected (via ground wire) to a common ground.
Figure 163 B-Bond Clamp
Product
Comcode
Packaging
AT-8544B SZ1
400366332
10/Pkg
MISCELLANEOUS 261
MISCELLANEOUS
Fibre
Cable Clamps
Clamps
Metallic Sheath Cable Clamp
Misc. Contents Page
The 12A1 Clamp is used to secure and ground one fibre optic metallic sheath cable. The clamp consists of a mounting bracket, two plastic half-clamps, and suitable grounding hardware. The 12A3L Cable Clamp provides the apparatus for securing high fibre count optical cable to the side of the LGX shelves. It contains a bracket that is bolted to the side of the shelves and receives one Universal Grip Block assembly cable clamp. The cable clamp can accommodate cables ranging in diameter from 0.25-inches to 1.50-inches. It includes a No. 2
Figure 164
B-Bond clamp for grounding the cables and a cable strap
Cable Clamps
for connecting the B-Bond clamp to the frame or another ground wire. It also includes a length of plastic tubing for protecting the fibres as they are routed into the shelves and
MISCELLANEOUS
a hose clamp for securing the tube to the cable.
262
Product
Comcode
Packaging
12A1
700025513
1/Pkg
12A3L
108527433
1/Pkg
MISCELLANEOUS
Fibre
Buffer Tubing Kit
Consumables
Tubing Kit
Misc. Contents Page
The D-181755 PVC Buffer Tubing Kit contains buffer tubing and cable end prep materials for direct termination of connectors on campus cable. This kit will buffer approximately 100 fibres, but contains only one blocking kit (one splitter kit should be ordered for each additional cable end). B-Sealant should also be ordered separately.
Figure 165 D -181755 Buffer Tubing Kit
Product
Comcode
D-181755
700006117
Kit Quantity
Description
1 Reel 5 1
Replacement Comcode
Quantity
64m Buffer Tube (900 micon)
845769272
5 Reels
Syringes
700007982
10 Syringes
Wire Marker Book
700007966
1
1 Bag
Rosin Bag
700002905
5
10 Ties
Miniature Cable Ties
105257448
50 Ties
1
Instruction Sheet
Unable to Order Individually
–
61cm
4.2mm Ins. Diam. Clear PVC Tubing
Unable to Order Individually
–
30cm
6mm Ins. Diam. Clear PVC Tubing
Unable to Order Individually
–
30.5cm
7.5 mm Ins. Diam. Clear PVC Tubing
Unable to Order Individually
–
2.9 x 0.4 mm Ins. Diam. PVC Tubing
Unable to Order Individually
–
61cm
4.8 Ins. Diam. Heat-Shrinkable Tubing
Unable to Order Individually
–
1 Splitter
Six-Unit Splitter D-181781
700011125
1 Splitter
1 Splitter
Eight-Unit Splitter D-181683
700006125
1 Splitter
MISCELLANEOUS
7.6m
263
MISCELLANEOUS
Fibre
Splitter Kit
Consumables
D-181781 Six-Unit
Misc. Contents Page
The D-181781 Six-Unit Splitter is used for blocking and organising fibres when prepping campus cable. The splitter has one core tube size (1.0cm) inlet and six PVC tube size outlets. The D-182806 Six-Unit Splitter fits 4.1mm (0.16in.) and 5.1mm (0.20in.) core tubes. This splitter can be used with low fibre count campus cable which has a small core tube size. They are the ideal devices to split bundled fibres into separate groups for routing to locations for shelves and cabinets.
Figure 166 Splitter Kit
Buffer Tubing Kits and B-Sealant should be ordered separately.
Product
Comcode
Packaging
D-181781
700011125
1/Pkg
D-182806
700010960
1/Pkg
Fibre
Splitter Kit
Consumables
D-181683 Eight-Unit The D-181683 Eight-Unit Splitter is used for blocking and organising fibres when prepping campus
MISCELLANEOUS
cable. The splitter has one core tube size (1.2cm) inlet and eight PVC tube size outlets. Buffer Tubing Kits and B-Sealant should be ordered separately.
264
Product
Comcode
Packaging
D-181683
700006125
1/Pkg
MISCELLANEOUS
Fibre
Splitter Kit
Consumables
B-Sealant
Misc. Contents Page
The B-Sealant is used for water blocking campus cable ends. It comes in a tooth paste-like 85g (3oz) tube. One tube can effectively water block approximately 5-10 cable ends.
Product
Comcode
Packaging
AT-8502
700010911
1/Pkg
Fibre
Splitter Kit
Consumables
Breakout Kit The Fitel Breakout Kit allows direct termination into fibre apparatus. Its features are: 24-inch, colour-coded 900µm tubing for protection and identification of the fibres along with an easy, snap-together housing that makes your fibres connector-ready. It’s simple to use since no epoxy or special tools are required. Select a 6-fibre or 12-fibre kit to suit your specific connectorisation needs. The 6-fibre kit can accept tubes up to 2.5mm and the 12-fibre kits can accept tubes up to 3.0mm. Figure 167 Breakout Kit
Comcode
Packaging
6-fibre
F00-300-008
1/Pkg
12-fibre
F00-300-009
1/Pkg
MISCELLANEOUS
Product
265
MISCELLANEOUS
Fibre
Cleave Sleeve & Leave
Splicing
CSL Splice System The D-182152 Kit consists of six single-fibre CSL (Cleave-Sleeve and Leave) mechanical splices and a condensed version of the splicing instructions. The CSL Splice System is a re-enterable mechanical splice for mechanically joining 250 micron coated and/or 900 micron buffered singlemode or multimode fibres. The splice consists of a clear plastic housing which contains a glass capillary tube, the plastic housing allows visual observation of the fibres during splicing. Index Matching Gel is contained within the splice capillary tube. The fibres are cleaved then inserted directly into the splice, so no polishing or adhesives are required. Splice assembly, including preparation of the fibres, can be performed in two minutes. It will obtain an average splice loss of less than 0.20 dB, and have an average return loss of less than -50 dB. The splice can be re-entered up to 10 times. The 1048A Tool Kit is required for assembling these splices.
Physical Specifications Storage/Operating Temperature Range: -40 to 85ºC Installation Time: 2 mins Fibre Size Acceptance: 125 µm OD Nominal Coating/Buffering Size Acceptance: 250 and 900 µm Average Pullout: > 4.5 N
Electrical Specifications Average Singlemode and Multimode Insertion Loss: < 0.20 dB
MISCELLANEOUS
Average Reflection: < -50 dB
266
Product
Comcode
Packaging
D-182152
106189442
6/Pkg
Misc. Contents Page
MISCELLANEOUS
Copper
4-Pair Tester
Testing
SYSTIMAX® 4-Pair Tester
Misc. Contents Page
The SYSTIMAX 4 Cable Tester Kit tests four copper pairs simultaneously, for polarity reversals, wire transpositions, continuity, AC and DC voltages, opens, shorts, and proper station operating conditions. A built-in warble tone source pinpoints trouble spots once they have been identified. The SYSTIMAX 4 Cable Tester Kit has a control switch and tricolour Light-Emitting Diode (LED) for each of the four pairs, plus a single “function” switch. The pocket-size tester operates on one 9 volt battery (included). The SYSTIMAX 4 Cable Tester Kit includes the tester, two 4-pair RJ45-to-110 block adapters, two 3-pair RJ45-to-110 block adapters, one
Figure 168
modular LED shorting plug (with a tri-colour LED for each
SYSTIMAX-4 Tester
pair), two modular RJ45-to-RJ45 cords (one 10cm long and the other 2m long), a protective carrying case with belt loop, and user instructions.
Product
Comcode
Packaging
SYSTIMAX Set Tester Kit
406165423
1/Pkg
MISCELLANEOUS 267
268
Comcode
Page
Comcode
Page
Comcode
Page
Comcode
Page
Comcodes & Products Chapter
10
269
Comcode
Page
Comcode
Page
Comcode
Page
Comcode
Page
Comcodes & Products Contents
Click Here Main Menu
COMCODE Index
273
PRODUCT Index
270
282
COMCODE
Comcode Index
Comcode
Page
Contents page
Comcode
Page
Comcode
Page
Comcode
Page
77
104386545
232
106563919
208
106908676
89
100017342
77
104401856
232
106569908
112
106908684
89
100017359
77
104405113
111
106583909
35
106908692
89
100017367
77
104410147
232
106583917
35
106908700
89
100849918
77
105012637
203
106583933
35
106908718
89
100959139
77
105012645
203
106630825
245
106908734
89
100959162
77
105197784
226
106630833
245
106919236
248
100959931
77
105257448
263
106657174
120
106926363
22
100959949
77
105272678
209
106657182
120
106928765
175
100959964
77
105275606
207
106657190
120
106939317
25
100959972
77
105276570
140
106657216
120
106939325
25
100960004
77
105282610
209
106657232
120
106961311
170
100963982
77
105289656
142
106658149
174
106961329
170
100964014
77
105289664
142
106658156
174
106969058
172
101129484
77
105307177
205
106664139
177
106969066
171
101619336
77
105345342
204
106664147
177
106973472
172
102605136
201
105345474
204
106664154
177
106973480
171
102655495
237
105356562
149
106727944
215
106976541
215
102689569
111
105356570
149
106736937
247
107001687
22
103184156
175
105501415
246
106790132
176
107025835
140
103786240
199
105514756
232
106790140
171
107058802
115
103796561
201
105535926
139
106790157
171
107058810
115
103801239
122
105581086
232
106790165
175
107058828
115
103801247
122
105597199
32
106824329
29
107058851
115
103801254
122
105597413
32
106824378
29
107058869
115
103895504
120
105597462
32
106824469
29
107058877
115
103895538
206
105597512
32
106830573
130
107058919
109
103923025
201
105689772
210
106830581
130
107058927
109
103941472
185
105736490
229
106830615
129
107058943
109
103942272
199
106062524
28
106830623
129
107058950
109
103963971
212
106066275
164
106836950
22
107059875
225
103963989
212
106189442
266
106836968
22
107059891
109
104032230
123
106230337
262
106837222
173
107059909
109
104141858
140
106274749
112
106837230
173
107059917
109
104141866
141
106310618
113
106857402
219
107059925
109
104141874
141
106310659
113
106871809
22
107065583
167
104158829
202
106371800
140
106871817
22
107067860
167
104270723
203
106485113
245
106896947
138
107067928
167
104270731
203
106503394
211
106908668
89
107078396
30
COMCODE
100016765
271
COMCODE
Comcode Index
COMCODE
Comcode
272
Page
Contents page
Comcode
Page
Comcode
Page
Comcode
Page
121
107656936
135
107733404
72
107287484
24
107656951
135
107733420
72
107321697
165
107656969
135
107733438
72
89
107321721
165
107656977
135
107733453
72
107122640
89
107321739
165
107656985
135
107733479
72
107122657
90
107328858
22
107656993
135
107733487
72
107122665
90
107347080
169
107670952
135
107733503
72
107122673
90
107428591
134
107670994
91
107733511
72
107132664
129
107428609
134
107671000
91
107733537
72
107132672
87
107431538
174
107671018
91
107733545
72
107132706
87
107431546
174
107671026
91
107733560
72
107132714
87
107486979
88
107671034
91
107733586
72
107136822
217
107486995
88
107671042
91
107733594
72
107147787
22
107487126
88
107671133
91
107733610
72
107148942
249
107487134
88
107671158
91
107733628
72
107150153
87
107487159
88
107671166
91
107736712
85
107150161
87
107487167
88
107671182
91
107736720
85
107150179
87
107487175
88
107671190
91
107736738
85
107150187
87
107487183
88
107671208
91
107736746
85
107150195
87
107487191
88
107671216
91
107736753
85
107150203
87
107487209
88
107671224
93
107736761
85
107150211
87
107509051
22
107671232
93
107736779
85
107150229
87
107535585
123
107671240
93
107736787
85
107150302
87
107536765
135
107671265
93
107736886
85
107150310
87
107536773
135
107671273
93
107736894
85
107150328
87
107536781
135
107671281
93
107736910
85
107150336
87
107536807
135
107733206
72
107736928
85
107150344
87
107536815
135
107733214
72
107736936
85
107150351
87
107536823
135
107733230
72
107736944
85
107150369
87
107536831
135
107733255
72
107736951
85
107150377
87
107536849
135
107733263
72
107736969
85
107151185
116
107536899
135
107733289
72
107736977
85
107151193
116
107573537
27
107733297
72
107736985
85
107193435
22
107573545
27
107733313
72
107736993
85
107213605
222
107611634
124
107733321
72
107737009
85
107214405
121
107638934
135
107733347
72
107737017
85
107239493
181
107653990
91
107733362
72
107737025
85
107244022
22
107656910
135
107733370
72
107737033
85
107244030
22
107656928
135
107733396
72
107754350
27
107079642
221
107267452
107122616
89
107122624
89
107122632
COMCODE
Comcode Index
Comcode
Page
Contents page
Comcode
Page
Comcode
Page
Comcode
Page
94
107774556
63
107895146
230
107987380
16
107755142
94
107783755
140
107895153
230
107987745
18
107755159
94
107800658
181
107895161
230
107987760
18
107755167
94
107810491
27
107895179
230
107987943
20
107755183
94
107818338
172
107895187
230
107987950
20
107755191
94
107831133
110
107895203
230
107987976
20
107755209
94
107831141
110
107895211
230
107987984
20
107755217
94
107855843
73
107895229
230
107987992
20
107755308
94
107855868
73
107920704
118
107988719
218
107755316
94
107855892
73
107920712
118
107991143
170
107755324
94
107856007
73
107920720
119
107992927
181
107755332
94
107856023
73
107920738
118
108004268
181
107755340
94
107856049
73
107920746
119
108006198
136
107755357
94
107856130
73
107952442
174
108036690
135
107755365
94
107856163
73
107952459
174
108036740
76
107755373
94
107856197
73
107975864
237
108036757
76
107755498
93
107856288
73
107984007
174
108036765
76
107755506
93
107856346
73
107984015
174
108036773
76
107755522
93
107856387
73
107984049
174
108062043
237
107755530
93
107882326
134
107984056
174
108062050
68
107755548
93
107882342
133
107984080
178
108062068
68
107755563
93
107882342
134
107984098
178
108062076
68
107755571
93
107882367
133
107984106
178
108062084
68
107755589
93
107882367
134
107984155
178
108062092
68
107755779
93
107894909
230
107984338
178
108065657
163
107755787
93
107894917
230
107984346
178
108065673
163
107755795
93
107894925
230
107984353
178
108065707
163
107755803
93
107894941
230
107984361
178
108065731
163
107755811
93
107894958
230
107987141
16
108065756
163
107755829
93
107894966
230
107987166
16
108065780
163
107755837
93
107894974
230
107987174
16
108065806
163
107755845
93
107894982
230
107987208
16
108065814
163
107764193
114
107895039
230
107987232
16
108065822
163
107764201
114
107895047
230
107987257
16
108066267
164
107764219
114
107895070
230
107987299
16
108066283
164
107765992
30
107895096
230
107987315
16
108066291
164
107766040
30
107895104
230
107987349
16
108066309
164
107766057
30
107895112
230
107987356
16
108066317
164
107774549
63
107895138
230
107987372
16
108072406
92
COMCODE
107755126
273
COMCODE
Comcode Index
COMCODE
Comcode
274
Page
Contents page
Comcode
Page
Comcode
Page
Comcode
Page
108072414
92
108232752
162
108373564
163
108535592
64
108072422
92
108232760
162
108373572
163
108535600
64
108072430
92
108232778
162
108373580
163
108535618
64
108072448
92
108234584
76
108373598
163
108535626
64
108072455
92
108234592
76
108373606
163
108535634
64
108072463
92
108234600
76
108373614
163
108535642
64
108072471
92
108234618
76
108462425
95
108535659
64
108120460
223
108234626
76
108462433
95
108535667
64
108156001
76
108236142
128
108462441
95
108535675
65
108156027
76
108236159
128
108462458
95
108535683
65
108156068
76
108236167
128
108462466
95
108535691
65
108168477
166
108257643
34
108462508
95
108535709
65
108168519
166
108262924
76
108509910
96
108535717
65
108168550
166
108262932
76
108509928
96
108535725
65
108180894
164
108263047
76
108509936
96
108535733
65
108189291
76
108263054
76
108509944
96
108535741
65
108189317
76
108288135
68
108509985
96
108535758
65
108189333
76
108288150
68
108510033
95
108535766
65
108189341
76
108288176
68
108510041
95
108535774
65
108189515
76
108288192
68
108510058
95
108537101
66
108199720
76
108288200
68
108510066
95
108537119
66
108199738
76
108288234
68
108510074
95
108537127
66
108199746
76
108288242
68
108510082
95
108537135
66
108199753
76
108288267
68
108510090
95
108537143
66
108199761
76
108288275
68
108523937
107
108537150
66
108208919
126
108288291
68
108527433
262
108537168
66
108208927
126
108301169
76
108527441
152
108537176
66
108208935
126
108313685
238
108528407
107
108537184
66
108208943
126
108320011
134
108528415
107
108537192
66
108208950
126
108320029
134
108528423
107
108537200
66
108224874
233
108320045
134
108528431
107
108538612
107
108230632
169
108337726
162
108528449
107
108540121
107
108232182
16
108340811
253
108528456
107
108544487
224
108232695
162
108340829
254
108528464
107
108544529
55
108232703
162
108356312
131
108528472
107
108561143
104
108232711
162
108373515
163
108528597
107
108564675
179
108232729
162
108373523
163
108535527
64
108564683
179
108232737
162
108373531
163
108535576
64
108564691
179
108232745
162
108373549
163
108535584
64
108564709
179
COMCODE
Comcode Index
Comcode
Page
Contents page
Comcode
Page
Comcode
Page
Comcode
Page
179
108566639
56
108567025
57
108571399
58
108565433
143
108566647
56
108567033
57
108571407
58
108565458
144
108566654
56
108567041
57
108571415
58
108565557
146
108566662
56
108567058
57
108571423
58
108565573
146
108566670
56
108567066
57
108571431
58
108565581
146
108566688
56
108567074
57
108571449
58
108565631
145
108566696
56
108567082
57
108571456
58
108565649
145
108566704
56
108567090
57
108571464
58
108565656
145
108566712
56
108567108
57
108571472
58
108565698
143
108566720
56
108567116
57
108571480
58
108565706
143
108566738
56
108567132
57
108571498
58
108565714
143
108566746
56
108567140
57
108571506
58
108565755
144
108566753
56
108567157
57
108571514
58
108565763
144
108566761
56
108570680
57
108571522
58
108565771
144
108566779
56
108570698
57
108571530
58
108566399
55
108566787
56
108570706
57
108571548
58
108566407
55
108566795
56
108570714
57
108571555
58
108566415
55
108566803
56
108570722
57
108571563
58
108566423
55
108566811
56
108570730
57
108571571
58
108566431
55
108566829
56
108570748
57
108571589
58
108566449
55
108566837
56
108570755
57
108571597
58
108566456
55
108566845
56
108570763
57
108571605
58
108566464
55
108566852
56
108570771
57
108571613
58
108566472
55
108566860
56
108570789
57
108571621
58
108566480
55
108566878
56
108570797
57
108571639
58
108566498
55
108566886
56
108570805
57
108571647
58
108566506
55
108566894
56
108570813
57
108571654
59
108566514
55
108566902
56
108571266
57
108571662
59
108566522
55
108566910
56
108571274
57
108571670
59
108566530
55
108566928
57
108571282
57
108571688
59
108566548
55
108566936
57
108571290
57
108572710
80
108566555
55
108566944
57
108571308
57
108572728
80
108566563
55
108566951
57
108571324
57
108572736
80
108566571
55
108566969
57
108571332
57
108572744
80
108566589
55
108566977
57
108571340
57
108572777
81
108566597
56
108566985
57
108571357
57
108572785
81
108566605
56
108566993
57
108571365
57
108572793
81
108566613
56
108567009
57
108571373
57
108572801
81
108566621
56
108567017
57
108571381
58
108572819
81
COMCODE
108564725
275
COMCODE
Comcode Index
COMCODE
Comcode
276
Page
Contents page
Comcode
Page
Comcode
Page
Comcode
Page
108572827
81
108574443
82
108650185
125
108680714
125
108572835
81
108574450
82
108650193
125
108680802
10
108572843
83
108574468
82
108650201
125
108680810
10
108572850
83
108574971
82
108650219
125
108680869
10
108572868
83
108574997
82
108650672
125
108680877
10
108572876
83
108575002
82
108650706
125
108680885
10
108572884
83
108575010
82
108661091
67
108680893
10
108572892
83
108593203
106
108661133
67
108681115
10
108572900
83
108601790
160
108661174
67
108681131
10
108573106
83
108601814
160
108661224
67
108681149
10
108573114
83
108601816
160
108661505
67
108681156
10
108573122
83
108601840
160
108661513
67
108681172
12
108573130
83
108601857
160
108665985
125
108681180
12
108573148
83
108601873
160
108665993
125
108681214
12
108573155
83
108601881
160
108666009
125
108681230
12
108573163
83
108601899
160
108666017
125
108687658
14
108573502
82
108601907
160
108666025
125
108687674
14
108573510
82
108601915
160
108666033
125
108687682
14
108573528
82
108601923
160
108669474
61
108687690
14
108573536
82
108619347
133
108669482
61
108688102
82
108573544
82
108619362
133
108669961
56
108688110
82
108573551
82
108619420
127
108669979
56
108688128
82
108573619
82
108619438
127
108669987
57
108688144
80
108573627
80
108619453
127
108669995
57
108688680
80
108573635
80
108619479
127
108670001
57
108688946
105
108573668
80
108619487
127
108670019
57
108689514
62
108573676
80
108619511
133
108670035
58
108689548
62
108573684
80
108622887
189
108670043
59
108689563
62
108573718
82
108622895
189
108671769
62
108689589
62
108573726
82
108627266
137
108671777
62
108689597
62
108573734
82
108627274
137
108671785
62
108694100
62
108573742
82
108627282
137
108671793
62
108694126
62
108573759
82
108634429
107
108671801
62
108694142
62
108573767
82
108635079
188
108671827
62
108694167
62
108573775
82
108635087
188
108671835
62
108694175
62
108573783
82
108637612
106
108671843
62
108694217
62
108573791
82
108637737
105
108671850
62
108694233
62
108573809
82
108640319
238
108671868
62
108694258
62
108574435
82
108641853
238
108671876
62
108694274
62
COMCODE
Comcode Index
Comcode
Page
Contents page
Comcode
Page
Comcode
Page
Comcode
Page
63
108834623
60
108868068
70
700002181
256
108707225
62
108834631
60
108868076
70
700002215
190
108707241
62
108834649
60
108868084
70
700002231
195
108707266
62
108834656
60
108868092
70
700002330
244
108707282
62
108834664
60
108868100
70
700002348
151
108707290
62
108834672
60
108868118
70
700002355
190
108707332
63
108834680
60
108879172
78
700002355
244
108707352
63
108834698
60
108879180
78
700002389
195
108707373
63
108834706
60
108879198
78
700002905
263
108707399
63
108834714
60
108879206
78
700003353
97
108707407
63
108836792
104
108922360
104
700003684
85
108708504
63
108836834
104
400366332
261
700003692
86
108708520
63
108867680
69
402023949
124
700003700
86
108708546
63
108867698
69
402023956
124
700003718
86
108708561
63
108867706
69
405245028
213
700003726
85
108708579
63
108867714
69
405423260
237
700003734
85
108708611
63
108867722
69
406165423
267
700003742
86
108708637
63
108867730
69
406477794
237
700003759
86
108708652
63
108867748
69
406678755
200
700003767
86
108708678
63
108867755
69
406678763
200
700003775
86
108708686
63
108867771
69
407004357
221
700003783
86
108708728
63
108867797
69
407036002
180
700003791
86
108708744
63
108867813
69
407036763
180
700003809
86
108708769
63
108867862
69
407050988
180
700003817
86
108708785
63
108867888
69
407484971
237
700003825
86
108708793
63
108867904
69
407728427
237
700003833
86
108738113
104
108867912
69
407732585
237
700003841
86
108744921
10
108867920
69
407900422
168
700003858
86
108744939
10
108867938
69
407900448
168
700003866
86
108744947
10
108867953
69
407900463
168
700003874
86
108744954
10
108867961
69
407900471
168
700003882
86
108793688
74
108867987
69
407901909
168
700003890
85
108793753
74
108867995
69
700002165
192
700003908
85
108834565
60
108868001
69
700002181
247
108834573
60
108868019
70
700002181
249
108834581
60
108868027
70
700002181
250
108834599
60
108868035
70
700002181
253
108834607
60
108868043
70
700002181
254
108834615
60
108868052
70
700002181
255
COMCODE
108694282
277
COMCODE
Comcode Index
COMCODE
Comcode
278
Page
Contents page
Comcode
Page
Comcode
Page
Comcode
Page
700003916
85
700005853
244
700006620
148
700008022
239
700003924
85
700005861
252
700006638
148
700008022
240
700003932
85
700005879
252
700006646
148
700008022
241
700003940
85
700005887
243
700006653
148
700008030
239
700003957
85
700005887
244
700006661
253
700008030
240
700004146
247
700005895
243
700006661
254
700008048
240
700004146
249
700005929
239
700006661
255
700008139
244
700004146
250
700005952
242
700006695
253
700008147
244
700004146
254
700005960
240
700006695
254
700008154
244
700004146
255
700006109
246
700006695
255
700008170
241
700004146
256
700006109
248
700006703
248
700008170
244
700004260
187
700006109
251
700006703
249
700008196
243
700004310
194
700006109
256
700006703
250
700008204
239
700004328
194
700006117
263
700006703
251
700008204
240
700004336
194
700006125
263
700006737
246
700008204
241
700004583
194
700006125
264
700006737
247
700008204
242
700004807
193
700006281
143
700006737
248
700008212
239
700004815
193
700006299
186
00006737
249
700008212
240
700004864
196
700006307
187
700006737
250
700008212
241
700004880
193
700006398
151
700006737
251
700008212
242
700004906
196
700006406
151
700006737
257
700008220
239
700005010
151
700006414
148
700006760
97
700008220
240
700005028
148
700006422
151
700006786
97
700008220
242
700005135
241
700006430
151
700006794
97
700008238
239
700005135
243
700006448
151
700006976
191
700008238
240
700005135
244
700006455
151
700006984
191
700008238
241
700005143
239
700006463
151
700006992
187
700008238
242
700005143
240
700006471
151
700007008
186
700008261
239
700005143
241
700006489
151
700007024
191
700008261
240
700005143
242
700006497
151
700007040
191
700008261
241
700005309
255
700006505
151
700007230
154
700008287
239
700005556
195
700006513
151
700007255
155
700008287
240
700005564
239
700006521
151
700007263
152
700008287
241
700005564
240
700006539
151
700007271
153
700008303
143
700005564
241
700006562
148
700007289
153
700008303
144
700005564
242
700006570
148
700007321
150
700008352
149
700005622
251
700006588
148
700007354
147
700008394
246
700005630
250
700006596
148
700007966
263
700008394
247
700005838
241
700006604
148
700007974
244
700008394
248
700005846
244
700006612
148
700007982
263
700008394
249
COMCODE
Comcode Index
Comcode
Page
Contents page
Comcode
Page
Comcode
700008394
250
700010671
45
700012073
700008394
251
700010689
45
700008394
253
700010705
45
700008394
254
700010713
700008394
255
700008444
40
700008451 700008469
Page
Comcode
Page
845769272
263
700012107
48
977700001
31
700012115
48
977700004
31
45
700012123
48
999900001
51
700010721
45
700012131
41
999900002
51
700010747
46
700012141
41
999900003
51
40
700010754
46
700012156
41
999900004
51
40
700010762
46
700012164
41
999900005
51
700008477
40
700010770
46
700012230
44
999900006
51
700008485
40
700010788
46
700012248
44
999900007
51
700008519
48
700010796
46
700012255
44
999900008
51
700008543
48
700010911
265
700012263
44
999900009
51
700009012
41
700010929
92
700012271
44
999900010
51
700009087
41
700010945
97
700012289
45
999900011
51
700009194
41
700010952
156
700012297
45
999900012
51
700009293
41
700010960
264
700012305
45
999900019
51
700009392
42
700010978
97
700012313
45
999900020
51
700009442
42
700010989
87
700012321
45
999900021
51
700009517
42
700010994
87
700012347
43
999900022
51
700009582
42
700011000
87
700012354
43
999900023
51
700009657
42
700011018
82
700012362
43
999900024
51
700009681
37
700011018
90
700012370
43
999900025
51
700009707
37
700011026
82
700012388
43
999900026
51
700009749
37
700011026
90
700012990
104
999900027
51
700009780
37
700011042
82
700021907
45
999900028
51
700009822
37
700011042
90
700023005
125
999900029
51
700009863
37
700011059
90
700023013
125
999900030
51
700010028
86
700011059
82
700023021
125
999901617
173
700010036
86
700011067
194
700025513
262
999901618
173
700010119
48
700011083
97
700025612
92
999901619
173
700010340
48
700011109
156
700032774
46
999901620
173
700010564
44
700011125
263
700032782
46
999901621
173
700010572
44
700011125
264
700032790
46
999901622
173
700010580
44
700011133
196
700032808
46
F00-300-008
265
700010580
44
700011158
239
700032865
44
F00-300-009
265
700010598
44
700011158
240
700032873
44
700010606
44
700011158
241
700032899
45
700010614
44
700011372
186
700059470
46
700010648
45
700012057
40
708573643
80
700010663
45
700012065
40
708573650
80
COMCODE
40
279
PRODUCT
Product Index
Product
Page
081004AWH
1071004CLL
1000SC1-DPLX
156
1000ST
156
100A3 LIU
Page
Product
Page
Product
Page
16
1100D3-35-19
129
110GB2-4500L
1071004COR
16
1100GS2-24
127
110GG3-2688L
107
1071004CRD
16
1100GS2-32
127
110KG3-2688L
107
138
1071004CRE
16
1100GS2-48
127
110P2CAT5F-12B 72
1010004AGY
28
1071004CSL
16
1100GS2-64
127
110P2CAT5F-15B 72
10100100AGY
29
1071004CSL
16
1100GS2-96
127
110P2CAT5F-2B
72
1010025AGY
29
1071004CSL
16
1100LS/MM/
110P2CAT5F-3B
72
1010050AGY
29
1071004CSL
16
LC-48
110P2CAT5F-5B
72
16
1100LS/MM/
110P2CAT5F-7B
72
1032B6 KIT
240
1071004CWH
1032F1 KIT
239
1071004CYL
16
SC-24
1032H KIT
241
1081004ABK
10
1100LS/MM/
1032J
238
1081004ABL
10
ST-24
1032K
238
146 146
120
110P2CAT5F-8B
72
110P2CAT5L-3B
73
146
110P2CAT5L-5B
73
1081004ABL
10
110A1 Bracket
123
110P2CAT5L-7B
73
1039B Cut Length
1081004AGN
10
110A2
121
110P2GS-15
68
Template
1081004AIV
10
110A3
110
110P2GS-3
68
1039B Cut Length
1081004ALB
10
110AB2-100FT
109
110P2GS-5
68
Template
1081004ALL
10
110AB2-300FT
109
110P2GS-7
68
1039B Cut Length
1081004AOR
10
110ABCAT5-50C 114
110P2GS-9
68
Template
1081004ARD
10
110AB-
110P2UP-GS-12
64
1039B Cut Length
1081004ASL
10
CAT5PS-JP12
110P2UP-GS-15
64
Template
1081004ASL
10
110AB-CAT5PS-
110P2UP-GS-18
64
1081004AWH
10
JP36
118
110P2UP-GS-2
64
10
110AC2-100FT
109
110P2UP-GS-3
64
10
239 240 241 242
Workstation
245
1081004AWH
1048B KIT
245
1081004AYL
118
110AC2-300FT
109
110P2UP-GS-4
64
140
110ANA1-25
229
110P2UP-GS-5
64
10LC1
140
110AW2-100
109
110P2UP-GS-6
64
10PLC-LS
137
110AW2-300
109
110P2UP-GS-7
64
22
10PSC-LS
137
110B1
113
110P2UP-GS-8
64
1061004CIV
22
10PST-LS
137
110B3
110
110P2UP-GS-9
64
1061004CLL
22
10SC1
140
110BB2-4500L
120
110P4CAT5F-12B 72
1061004COR
22
10SC1-DPLX
140
110BB-CAT5PS-
1061004CRD
22
1100C1-35-19
130
JP12FTB
118
110P4CAT5F-2B
72
1061004CSL
22
1100C1-70-19
130
110BG3-2688L
107
110P4CAT5F-3B
72
1061004CSL
22
1100CAT5PS-24 126
110C-3
122
110P4CAT5F-5B
72
1061004CWH
22
1100CAT5PS-32 126
110C-4
122
110P4CAT5F-7B
72
1061004CYL
22
1100CAT5PS-48 126
110C4W
107
110P4CAT5F-8B
72
1061025CSL
24
1100CAT5PS-64 126
110C-5
122
110P4CAT5L-3B
73
1071004CBL
16
1100CAT5PS-96 126
110CG3-2688L
107
110P4CAT5L-5B
73
1071004CGN
16
1100D1-35-19
129
110DW2-100
109
110P4CAT5L-7B
73
1071004CIV
16
1100D2-35-19
129
110DW2-300
109
110P4GS-15
68
1061004CBK
PRODUCT
Product
12
1041B Handheld
280
Contents page
22
10A
1061004CBL
22
1061004CBR
22
1061004CGN
110P4CAT5F-15B 72
PRODUCT
Product Index
Product
Page
Contents page
Product
Page
Product
Page
Product
Page
68
110P8UP-GS-12
66
Horz. Trough
104
119P8CMLL-12B 63
110P4GS-5
68
110P8UP-GS-15
66
110UPHLDR
107
119P8CMLL-3B
62
110P4GS-7
68
110P8UP-GS-18
66
110UPT-Kit-
119P8CMLL-5B
62
110P4GS-9
68
110P8UP-GS-2
66
Trough
104
119P8CMLL-7B
62
110P4UP-GS-12
65
110P8UP-GS-3
66
110UTC
106
119P8CMLL-9B
62
110P4UP-GS-15
65
110P8UP-GS-4
66
110W4A4
113
119P8CMOR-12B 63
110P4UP-GS-18
65
110P8UP-GS-5
66
110WB2-4500L
120
119P8CMOR-3B
63
110P4UP-GS-2
65
110P8UP-GS-6
66
110WG3-2688L
107
119P8CMOR-5B
63
110P4UP-GS-3
65
110P8UP-GS-7
66
110YB2-4500L
120
119P8CMOR-7B
63
110P4UP-GS-4
65
110P8UP-GS-8
66
110YG3-2688L
107
119P8CMOR-9B
63
110P4UP-GS-5
65
110P8UP-GS-9
66
1110A1-3
200
119P8CMRD-12B 63
110P4UP-GS-6
65
110PA2-300FT
115
1110A1-4
200
119P8CMRD-3B
63
110P4UP-GS-7
65
110PA2-900FT
115
117CM-15
61
119P8CMRD-5B
63
110P4UP-GS-8
65
110PB2-300FT
115
117CM-30
61
119P8CMRD-7B
63
110P4UP-GS-9
65
110PB2-4500L
120
119P8 CM-12B
62
119P8CMRD-9B
63
110P6CAT5F-12B 72
110PB2-900FT
115
119P8 CM-15B
62
119P8CMSA-12B 63
110P6CAT5F-15B 72
110PBCAT5-150C 114
119P8 CM-18B
62
119P8CMSA-3B
63
110P6CAT5F-2B
72
110PBCAT5-450C 114
119P8 CM-3B
62
119P8CMSA-5B
63
110P6CAT5F-3B
72
110PB-CAT5PS-
119P8 CM-4B
62
119P8CMSA-7B
63
110P6CAT5F-5B
72
JP108B
119P8 CM-5B
62
119P8CMSA-9B
63
110P6CAT5F-7B
72
110PB-CAT5PS-
119P8 CM-6B
62
119P8CMYW-12B 63
110P6CAT5F-8B
72
JP36B
119
119P8 CM-7B
62
119P8CMYW-3B 63
110P6CAT5L-3B
73
110PC2-300FT
115
119P8 CM-8B
62
119P8CMYW-5B 63
110P6CAT5L-5B
73
110PC2-900FT
115
119P8 CM-9B
62
119P8CMYW-7B 63
110P6CAT5L-7B
73
110PG3-2688L
107
119P8CM-2B
62
119P8CMYW-9B 63
110P8CAT5F-12B 72
110RA2-12
225
119P8CMBL-12B 62
119P8VP-12
67
110P8CAT5F-15B 72
110RA-38
124
119P8CMBL-3B
62
119P8VP-15
67
110P8CAT5F-2B
72
110RD2-200-19
123
119P8CMBL-5B
62
119P8VP-3
67
110P8CAT5F-3B
72
110RG3-2688L
107
119P8CMBL-7B
62
119P8VP-5
67
110P8CAT5F-5B
72
110SG3-2688L
107
119P8CMBL-9B
62
119P8VP-7
67
110P8CAT5F-7B
72
110TA1-50
112
119P8CMGN-12B 62
119P8VP-9
67
110P8CAT5F-8B
72
110TB2-50
112
119P8CMGN-3B 62
12 LC Duplex
110P8CAT5L-3B
73
110U19M
107
119P8CMGN-5B 62
Panel
110P8CAT5L-5B
73
110U2R
107
119P8CMGN-7B 62
12 SC Duplex
110P8CAT5L-7B
73
110UB1-112FT
119P8CMGN-9B 62
Panel
148
110P8GS-15
68
VisiPatch 110 Kit 104
119P8CMIV-12B
62
12 SC Panel
148
110P8GS-3
68
110UB1-336FT
119P8CMIV-3B
62
12 SC-Duplex-EW
110P8GS-5
68
VisiPatch 110 Kit 104
119P8CMIV-5B
62
Panel
110P8GS-7
68
110UHD-S8
119P8CMIV-7B
62
12 SC-EW Panel 148
110P8GS-9
68
110UHPT-Uni.
119P8CMIV-9B
62
12 ST Panel
119
105
PRODUCT
110P4GS-3
148
148 148
281
PRODUCT
Product Index
Product
Page
Page
Product
Page
Product
Page
Tool
244
24SC1EW Panel 151
370C1
208
120P4CAT5F-12B 63
183U1
148
24ST1 Panel
151
380A
215
120P4CAT5F-20B 63
184U1
151
24ST1EW Panel 151
380B
217
12A1
260
188B1
111
24ST1S-EW
380BA
218
12A2
260
188B2
111
Panel
151
381A
219
12A3L
260
188C3
116
2500CAT5PS-24B 128
383A
221
12-fibre
265
188D3
116
2500CAT5PS-48B 128
383A Power
188UT1-50
120
2512CATPS-48
128
Supply 220V
221
19 inch Bracket 152
258A
201
384A
222
1A4
141
258AF
201
385DP
223
1A6
141
258B
201
386S
224
1AF1-16LG
149
2A1
192
3B1-EW
232 232
Panel
151
12SC1 DPLX Panel
151
12SC1 DPLX-EW Panel
151
1AM1-12LG
149
3010LSZH
31
3C1S
12SC1 Panel
151
1AMF1-6LG
143
3010LSZH
31
3DDX-002-HXM 46
97
3051A-004
27
3DDX-004-HXM 46
12SC1EW Panel 151
1LC-5
12ST1 Panel
151
1SC-5
97
3061A-004
27
3DDX-006-HXM 46
12ST1EW Panel 151
1STP-5
97
3061A-004
27
3DDX-008-HXM 46
12ST1S-EW
1U-17 Trough
151
3061A-025
27
3DDX-012-HXM 46
1U-19
149
3071004ABL
20
3DDX-018-HXM 46
200A LIU
139
3071004ABL
20
3DNX-006-HXM 45
Panel
151
1504B Buffer Retention Tool
245
1510A Polishing Tool Tool
239 240
1510A Polishing Tool
242
1510A1 Polishing Tool (ST/SC)
241
1510B Crimping Tool
239
1510B Crimping Tool
240
1510B Crimping Tool
242
1510C Connector Holder (SC)
241
1510C Curring Fixtures
200A1 Curring
3071004AWH
20
3DNX-008-HXM 45
240
3071004AWH
20
3DNX-012-HXM 45
2010004BWH
30
3071004AWH
20
3DNX-024-HXM 45
2010025BWH
30
3081004ABL
14
3DNX-036-HXM 45
2010050BWH
30
3081004ABL
14
3DNX-048-HXM 45
2010100BWH
30
3081004AWH
14
3DNX-072-HXM 45
2061004BWH
25
3081004AWH
14
3DSX-006-HXM
44
2061004BWH
25
3345A
175
3DSX-008-HXM
44
2071004AWH
18
353A3
211
3DSX-012-HXM
44
2071004AWH
18
355A
203
3DSX-024-HXM
44
2081004ABK
12
355AF
203
3DSX-036-HXM
44
2081004ABL
12
355B
203
3DSX-048-HXM
44
2081004ASL
12
355BF
203
3DSX-072-HXM
44
24 SC Panel
Oven
1510A Polishing
PRODUCT
Product
12 ST-EW Panel 148
12LC1 DPLX
242
1510LC Crimping
282
Contents page
148
356A
202
3LC-5
97
24 SC-EW Panel 148
365A
209
3SC-5
97
24 ST Panel
148
366A
209
3STP-1
97
24 ST-EW Panel 148
367A
207
3STP-5
24LC1 DPLX
368A
204
400E
206
97
Panel
151
368AF
204
400K
205
24SC1 Panel
151
369A
210
440A4
226
PRODUCT
Product Index
Contents page
Product
Page
451A-50
199
Product
4DNX-048-HXM 45
Page
Product 700A Stripping
451A-61
199
Page
Product
Page
AT-34M12O6-004 51
4DNX-072-HXM 45
Tool
241
AT-34M12O6-006 51
4860B30 LSZH
86
4DSX-006-BXD
44
700A8
185
AT-34M12O6-008 51
4861B30 LSZH
86
4DSX-008-BXD
44
788 KIT
237
AT-34M12O6-012 51
489ACAI-025
230
4DSX-012-BXD
44
788H1 Tool
237
AT-34M12O6-016 51
489ACAI-050
230
4DSX-024-BXD
44
788K1 Tool
237
AT-34M12O6-018 51
489ACAI-100
230
4DSX-036-BXD
44
788M2 Head
237
AT-34M12O6-024 51
489ACCI-025
230
4DSX-048-BXD
44
811A Panel
215
AT-34M12O6-030 51
489ACCI-050
230
4DSX-072-BXD
44
8762D Kit
237
AT-34M12O6-036 51
489ACCI-100
230
600A1
88A2
121
AT-34M12O6-048 51
489ACMI-025
230
600ALS/MM/
489ACMI-050
230
SC-24
489ACSI-025
230
600ALS/MM/
489ACSI-050
230
SC-48
489ACSI-100
230
600ALS/MM/
489BCBI-025
230
ST-24
489BCBI-050
230
600B Connector
489BCBI-100
230
holders
489BCCI-025
230
600B Connector
489BCCI-050
230
Holders
489BCCI-100
230
489BCMI-025
230
489BCMI-050
230
600B1 Connector
489BCMI-100
230
Holder (ST)
241
489BCSI-025
230
600B2
150
489BCSI-050
230
600BLS/MM/
489BCSI-100
230
LC-48
4B1-EW
232
600BLS/MM/
4C1S
232
SC-24
4C3S-75
232
600BLS/MM/
147
971A-2 Holder 143
Block
AT-34M12O6-060 51 244
975A Cleaving 143
Tool
239
975A Cleaving 143
Tool
240
975A Cleaving 239
AT-8502
265
AT-8544B SZ1
259
AT-8662
124
AT-8662D
124
AT-RU912O6-004 51 AT-RU912O6-006 51
77
AT-RU912O6-008 51
A25B-15 SGL
77
AT-RU912O6-012 51
600B ST Connector
A25B-25 SGL
77
AT-RU912O6-016 51
Holders
A25B-50 SGL
77
AT-RU912O6-018 51
A25D-10 DBL
77
AT-RU912O6-024 51
A25D-10 SGL
77
AT-RU912O6-030 51
A25D-100 SGL
77
AT-RU912O6-036 51
A25D-15 SGL
77
AT-RU912O6-048 51
A25D-25 DBL
77
AT-RU912O6-060 51
A25D-25 SGL
77
AT-RU912O6-072 51
A25D-30 SGL
77
B25A-10 DBL
77
A25D-50 SGL
77
B25A-100 DBL
77
Adhesive
247
B25A-30 DBL
77
4DDX-004-BXD
46
ST-24
4DDX-006-BXD
46
64m Buffer Tube
4DDX-008-BXD
46
(900 micon)
4DDX-012-BXD
46
4DDX-018-BXD
46
242
144 144 144
Adhesive
249
B25A-60 DBL
77
263
Adhesive
250
BC-002D-ZHX
37
6-fibre
265
Adhesive
253
BC-004D-ZHX
37
6-inch Scale
239
Adhesive
254
BC-006D-ZHX
37
4DNX-006-HXM 45
6-inch Scale
240
Adhesive
255
BC-012D-ZHX
37
4DNX-008-HXM 45
700A Stripping
ADHESIVE
4DNX-012-HXM 45
Tool
4DNX-024-HXM 45
700A Stripping
4DNX-036-HXM 45
Tool
239 240
256
BC-024D-ZHX
37
ANMW
35
BC-036D-ZHX
37
ANMW
35
Blank Panel
ANMW
35
BRKT-110PWB HGR
PRODUCT
241
A25B-10 SGL 240
Tool
AT-34M12O6-072 51
140
283
PRODUCT
Product Index
Product
Page
Page
Product
Page
Product
Page
105
CC525AR-015A
76
D-182709 KIT
247
D8CM-10-GY
55
C1001B-2
190
CC525AR-025A
76
D-182720 KIT
250
D8CM-10-IV
56
C1001B-2
CC525AR-050A
76
D-182737 KIT
242
D8CM-10-LL
58
Multimode LC
CC525CC-005A
76
D-182738 KIT
248
D8CM-10-OR
57
Adapter
244
CC525CC-010A
76
D-182739 KIT
251
D8CM-10-RD
57
C1001B-2-LS
189
CC525CC-015A
76
D-182804 KIT
249
D8CM-10-SB
57
C1101A-2
190
CC525CC-025A
76
D-182806
264
D8CM-10-YL
58
C2000A-2
196
CC525CC-050A
76
D-182905 KIT
243
D8CM-14-BL
56
C2000A-2/100
196
CC525CN-050A
76
D-182918 KIT
252
D8CM-14-GN
57
C3000A-2
196
CC525CN-100A
76
D-182919 KIT
252
D8CM-14-GY
55
C5P4T-16
233
CC525CP-005A
76
D-182959 KIT
244
D8CM-14-IV
56
C6000A-4
193
CC525CP-010A
76
D-182983 KIT
253
D8CM-14-LL
58
C6060A-4
193
CC525CP-015A
76
D-182984 KIT
254
D8CM-14-OR
57
C6061A-4
193
CC525CP-025A
76
D-182985 KIT
255
D8CM-14-RD
57
C6061A-4-LS
189
CC525CP-050A
76
D-183033
238
D8CM-14-SB
57
CA 3-NCA4158 4/24
CC525RC-005A
76
D8CH-DEWH-1
60
D8CM-14-YL
59
R1000
CC525RC-010A
76
D8CH-DEWH-10 60
D8CM-15-BL
56
CC525RC-015A
76
D8CH-DEWH-14 60
D8CM-15-GN
57
CC525RC-025A
76
D8CH-DEWH-15 60
D8CM-15-GY
55
CC525RC-050A
76
D8CH-DEWH-19 60
D8CM-15-IV
56
CCW-F 1/24
32
D8CH-DEWH-2
60
D8CM-15-LL
58
CCW-F 2/24
32
D8CH-DEWH-25 60
D8CM-15-OR
57
CCW-F 3/24
32
D8CH-DEWH-3
D8CM-15-RD
57
CCW-F 4/24
32
D8CH-
ABC-006-SHX
34 40
CA-LG-BLDGABC-008-SHX
40
CA-LG-BLDGABC-012-SHX
40
CA-LG-BLDGABC-024D-SHX
41
CA-LG-BLDGABC-036D-SHX ABC-048D-SHX
41
CAP M-series
48
CLBA10-024B-SHX
41
48
CLBA10-012B-ZHX
CA-LG-BLDGABC-072D-SHX
CLBA10-012B-SHX
41
CA-LG-BLDG-
PRODUCT
Product
STL
CA-LG-BLDG-
D8CM-15-SB
57
DEWH-30M
60
D8CM-15-YL
59
D8CH-DEWH-4
60
D8CM-19-BL
56
D8CH-DEWH-5
60
D8CM-19-GN
57
D8CH-DEWH-6
60
D8CM-19-GY
55
D8CH48
CLBA10-036B-SHX
60
D8CM-19-IV
56
DEWH-6M
60
D8CM-19-LL
58
D8CH-DEWH-7
60
D8CM-19-OR
57
48
D8CH-DEWH-8
60
D8CM-19-RD
57
164
D-180880
175
D8CH-DEWH-9
60
D8CM-19-SB
58
CC525AC-005A
76
D-181683
264
D8CM Crossover 78
D8CM-19-YL
59
CC525AC-010A
76
D-181706
142
D8CM Crossover 78
D8CM-1-BL
56
CC525AC-015A
76
D-181707
142
D8CM Crossover 78
D8CM-1-GN
57
CC525AC-025A
76
D-181755
263
D8CM Crossover 78
D8CM-1-GY
55
CC525AC-050A
76
D-181781
264
D8CM-100-GY
55
D8CM-1-IV
56
CC525AR-005A
76
D-182038 KIT
246
D8CM-10-BL
56
D8CM-1-LL
58
CC525AR-010A
76
D-182152
266
D8CM-10-GN
57
D8CM-1-OR
56
HDM
284
Contents page
PRODUCT
Product Index
Product D8CM-1-RD
Page
Contents page
Product
57
D8CM-4-SB
D8CM-1-SB
57
D8CM-1-YL
58
D8CM-200-GY
Page
Product
57
D8CM-8-BL
D8CM-4-YL
58
D8CM-50-BL
56
55
D8CM-50-GN
D8CM-25-BL
56
D8CM-25-GN
57
D8CM-25-GY
55
D8CM-25-IV
56
D8CM-25-LL
Page
Product
Page
56
D8MC6NWH5BA 70
D8CM-8-GN
57
D8MC6PBK20BA 69
D8CM-8-GY
55
D8MC6PBK25BA 69
57
D8CM-8-IV
56
D8MC6PBK33BA 69
D8CM-50-GY
55
D8CM-8-LL
58
D8MC6PBK40BA 69
D8CM-50-IV
56
D8CM-8-OR
57
D8MC6PBK50BA 69
D8CM-50-LL
58
D8CM-8-RD
57
D8MC6PIV20BA 69
D8CM-50-OR
57
D8CM-8-SB
57
D8MC6PIV25BA 69
58
D8CM-50-RD
57
D8CM-8-YL
58
D8MC6PIV33BA 69
D8CM-25-OR
57
D8CM-50-SB
58
D8CM-9-BL
56
D8MC6PIV40BA 69
D8CM-25-RD
57
D8CM-50-YL
59
D8CM-9-GN
57
D8MC6PIV50BA 69
D8CM-25-SB
58
D8CM-5-BL
56
D8CM-9-GY
55
D8MC6
D8CM-25-YL
59
D8CM-5-GN
57
D8CM-9-IV
56
PWH20BA
D8CM-2-BL
56
D8CM-5-GY
55
D8CM-9-LL
58
D8MC6
D8CM-2-GN
57
D8CM-5-IV
56
D8CM-9-OR
57
PWH25BA
D8CM-2-GY
55
D8CM-5-LL
58
D8CM-9-RD
57
D8MC6
D8CM-2-IV
56
D8CM-5-OR
56
D8CM-9-SB
57
PWH33BA
D8CM-2-LL
58
D8CM-5-RD
57
D8CM-9-YL
58
D8MC6
D8CM-2-OR
56
D8CM-5-SB
57
D8MC6NBK10BA 69
PWH40BA
D8CM-2-RD
57
D8CM-5-YL
58
D8MC6NBK15BA 69
D8MC6
D8CM-2-SB
57
“D8CM-6””-GY” 55
D8MC6NBK20BA 69
PWH50BA
70
D8CM-2-YL
58
D8CM-6-BL
56
D8MC6NBK25BA 69
D8NA-DE15
74
D8CM-300-GY
55
D8CM-6-GN
57
D8MC6NBK33BA 69
D8NA-DE25
74
D8CM-30M-GY
55
D8CM-6-GY
55
D8MC6NBK5BA 69
D8NA-DE50
74
D8CM-3-BL
56
D8CM-6-IV
56
D8MC6NIV10BA 69
D8CM-3-GN
57
D8CM-6-LL
58
D8MC6NIV15BA 69
D8CM-3-GY
55
D8CM-6M-GY
55
D8MC6NIV20BA 69
D8CM-3-IV
56
D8CM-6-OR
57
D8MC6NIV25BA 69
D8CM-3-LL
58
D8CM-6-RD
57
D8MC6NIV33BA 69
D8CM-3-OR
56
D8CM-6-SB
57
D8MC6NIV5BA
D8CM-3-RD
57
D8CM-6-YL
58
D8MC6
D8CM-3-SB
57
D8CM-7-BL
56
NWH10BA
D8CM-3-YL
58
D8CM-7-GN
57
D8MC6
D8CM-4-BL
56
D8CM-7-GY
55
NWH15BA
D8CM-4-GN
57
D8CM-7-IV
56
D8MC6
D8CM-4-GY
55
D8CM-7-LL
58
NWH20BA
D8CM-4-IV
56
D8CM-7-OR
57
D8MC6
D8CM-4-LL
58
D8CM-7-RD
57
NWH25BA
D8CM-4-OR
56
D8CM-7-SB
57
D8MC6
D8CM-4-RD
57
D8CM-7-YL
58
NWH33BA
70 70 70 70
PRODUCT
69 70 70 70 70 70
285
PRODUCT
Product Index
Product
Page
Page
Product
Page
Product
Page
74
FL2STII-STII-02
87
iPSMNETMGR
D8NA-SE100
74
FL2STII-STII-04
87
-NA
D8NA-SE18
74
FL2STII-STII-06
87
iPSMNETMGR-
D8NA-SE33
74
FL2STII-STII-08
87
UK
125
LDNX-048-HXG 43
D8NA-SE65
74
FL2STII-STII-10
87
KS-22035-L2
237
LDNX-096-HXG 43
FL2STII-STII-15
87
L2300-BL
135
LF00
FL2STII-STII-20
87
L2300-BR
135
LF80 Mark V clip 168
135
LF80 Mark VI clip168
Tool
237
LDNX-006-HXG 43 125
LDNX-012-HXG 43 LDNX-024-HXG 43
168
Designation Cover -
FL2STII-STII-25
87
L2300-GN
Clear Plastic
104
FL2STII-SC-02
94
L2300-GY
135
LF81
169
DM2150
134
FL2STII-SC-04
94
L2300-OR
135
LF82IT
170
FL2STII-SC-06
94
L2300-PL
135
LF83IT
170
135
LGBC-002D-LHO 40
DM2160GS Module
133
FL2STII-SC-08
94
L2300-RD
DM2250B
134
FL2STII-SC-10
94
L2300-WH
135
LGBC-002D-LPX 42
DTLS/600A-5
143
L2300-YL
135
LGBC-004D-LHO 40
Label Sheet
135
LGBC-004D-LPX 42
Label Sheet
135
LGBC-006D-LHO 40
Label Sheet
135
LGBC-006D-LPX 42
Label Sheet
135
LGBC-008D-LHO 40
Label Sheet
135
LGBC-008D-LPX 42
Label Sheet
135
LGBC-012D-LHO 40
Label Sheet
135
LGBC-012D-LPX 42
Label Sheet
135
LGBC-024D-LHO 41
DTLS/600B-1.75 144 Eight-Unit Splitter
PRODUCT
Product
D8NA-DE75
D-914 Impact
D-181683
263
Epoxy
246
Epoxy
248
Epoxy
251
EPOXY
256
Fibre Outlet
180
Fibre Outlet
180
Fibre Outlet
180
FL1STII-STII-02
87
FL1STII-STII-04
87
FL1STII-STII-06
87
FL1STII-STII-08
87
FL1STII-STII-10
87
FL1STII-STII-15
87
FL2STII-SC-15
94
FL2STII-SC-20
94
FL2STII-SC-25
94
Fleximax HD
131
FS1STII-STII-04
87
FS1STII-STII-10
87
FS2STII-STII-10
87
Heat Tube Assemblies
244
HLDR-110FDLH New Label
104
iP1100GS24
125
iP1100GS48
125
iP1100PS24
125
iP1100PS48
125
iPNETMGR-EU 125
LC BTW Connector
LGBC-036D-LHO 41
Holders
LGBC-048D-LHO 41
244
LGBC-072D-LHO 41
LC Connector Holder
241
Holder
243
LGIO-036B-LHX 48 LGMC-001B-LRX 87
LC Cut Length Template
LGIO-012B-LHX 48 LGIO-024B-LHX 48
LC Connector
244
LGMC-002B-LRX 87
87
iPNETMGR-NA 125
LC Jumper
FL1STII-STII-25
87
iPNETMGR-UK 125
Connector
FL1STII-SC-02
94
iPPWRSPLY-EU 125
Holders
244
for 600A
FL1STII-SC-04
94
iPPWRSPLY-NA 125
LC Microscope
244
Lid Cover
FL1STII-SC-06
94
iPPWRSPLY-UK 125
LC Microscope
94
iPRCKMGR-EU 125
w/adapter
FL1STII-SC-10
94
iPRCKMGR-NA 125
LC Polishing
FL1STII-SC-15
94
iPRCKMGR-UK 125
Fixture
FL1STII-SC-20
94
iPSMNETMG
94
-EU
FL1STII-STII-20
FL1STII-SC-08
FL1STII-SC-25
286
Contents page
125
LGMC-002B-SRX 87 Lid Cover
for 600B
143 144
LL1SC-SC-02
89
LL1SC-SC-04
89
LL1SC-SC-05
89
LC Stripper Guide
LL1SC-SC-10
89
Tube for 1026A 244
LL1SC-SC-15
89
243 243
PRODUCT
Product Index
Product
Page
Contents page
Product
Page
Product
Page
Product
Page
LL1SC-SC-20
89
LZ2SC-STII-40
83
M1BH-003
165
MCAN-DL-262 175
LL1SC-SC-25
89
LZ2SC-STII-50
83
M1BH-246
165
MFUGA-262
171
LL2SC-SC-02
89
LZ2STII-STII-04
83
M1BH-262
165
MFUGA-290
171
LL2SC-SC-04
89
LZ2STII-STII-06
83
M20AP-003
167
MFUGAIS-262
172
LL2SC-SC-05
89
LZ2STII-STII-10
83
M20AP-246
167
MFUGAIS-290
172
LL2SC-SC-10
89
LZ2STII-STII-20
83
M20AP-262
167
MFUGAS-262
171
LL2SC-SC-15
90
LZ2STII-STII-30
83
M30MC-003
177
MFUGAS-290
171
LL2SC-SC-20
90
LZ2STII-STII-40
83
M30MC-246
177
MGS300BH-003 160
LL2SC-SC-25
90
LZ2STII-STII-50
83
M30MC-262
177
MGS300BH-112 160
LS1SC-SC-04
82
M02714-246
173
M40A1-B-262
181
MGS300BH-123 160
LS1SC-SC-04
90
M02714-262
173
M40DSC-B-262 181
MGS300BH-215 160
LS1SC-SC-10
82
M1000P5
136
M40RJ4A-B-262 181
MGS300BH-226 160
LS1SC-SC-10
90
M101SMB-246
174
M40ST4-B-262
181
MGS300BH-246 160
LS2SC-SC-05
82
M101SMB-262
174
M61A-003
163
MGS300BH-262 160
LS2SC-SC-05
90
M102SMB-246
174
M61A-112
163
MGS300BH-270 160
LS2SC-SC-10
82
M102SMB-262
174
M61A-123
163
MGS300BH-317 160
LS2SC-SC-10
90
M104SMB-246
174
M61A-226
163
MGS300BH-318 160
LSC2U-024/5
155
M104SMB-262
174
M61A-246
163
MGS300BH-361 160
LSS1U-072/5
154
M106SMB-246
174
M61A-262
163
Miniature
LST1F-072/7
153
M106SMB-262
174
M61A-270
163
Cable Ties
LST1P-48ST
152
M110 Blade
237
M61A-317
163
ML1STII-STII-06 88
LST1U-072/7
153
M112SMB-246
174
M61A-318
163
ML1STII-STII-10 88
M112SMB-262
174
M61F-226
164
ML1STII-SC-02
93
M12-262
170
M61F-246
164
ML1STII-SC-04
93
M12D
168
M61F-262
164
ML1STII-SC-06
93
M12E
172
M61F-270
164
ML1STII-SC-08
93
M12L-246
166
M61F-317
164
ML1STII-SC-10
93
145
M12LG-262
169
M61F-318
164
ML1STII-SC-15
93
LZ2SC-SC-04
81
M13CLS-003
179
M61H-003
163
ML1STII-SC-20
93
LZ2SC-SC-06
81
M13CLS-215
179
M61H-112
163
ML1STII-SC-25
93
LZ2SC-SC-10
81
M13CLS-246
179
M61H-123
163
ML1LC-LC-04
85
LZ2SC-SC-20
81
M13CLS-262
179
M61H-226
163
ML1LC-LC-05
85
LZ2SC-SC-30
81
M13CLS-270
179
M61H-246
163
ML1LC-LC-06
85
LZ2SC-SC-40
81
M13L-246
166
M61H-262
163
ML1LC-LC-08
85
LZ2SC-SC-50
81
M14D
168
M61H-270
163
ML1LC-LC-10
85
LZ2SC-STII-04
83
M14L-246
166
M61H-317
163
ML1LC-LC-15
85
LZ2SC-STII-06
83
M18930-246
173
M61H-318
163
ML1LC-LC-20
85
LZ2SC-STII-10
83
M18930-262
173
M61H-361
163
ML1LC-LC-25
85
LZ2SC-STII-20
83
M18932-246
173
M81-246
173
ML1SC-SC-02
91
LZ2SC-STII-30
83
M18932-262
173
M81-262
173
ML1SC-SC-04
91
LSTLS/MM/ LC-144/7
145
LSTLS/MM/ SC-072/7
145
LSTLS/MM/
PRODUCT
ST-072/7
263
287
PRODUCT
Product Index
PRODUCT
Product
288
Page
Contents page
Product
Page
Product
Page
Product
Page
ML1SC-SC-05
91
ML2LC-LC-20
85
MPS100E - 262
162
Music Wire
250
ML1SC-SC-10
91
ML2LC-LC-25
85
MPS100E - 270
162
Music Wire
251
ML1SC-SC-15
91
ML2LC-LC-30
85
MPS100E - 317
162
Music Wire
253
ML1SC-SC-20
91
ML2LC-LC-35
85
MPS100E - 318
162
Music Wire
254
ML1SC-SC-25
Music Wire
255
91
ML2LC-LC-40
85
MPS100E - 361
162
ML2STII-STII-02 88
ML2LC-LC-50
85
MS1LC-LC-04
85
MZ2STII-STII-04 80
ML2STII-STII-04 88
ML2LC-LC-75
85
MS1LC-LC-05
85
MZ2STII-STII-10 80
ML2STII-STII-06 88
ML2LC-MJ-04
95
MS1LC-LC-06
85
MZ2STII-STII-20 80
ML2STII-STII-08 88
ML2LC-MJ-06
95
MS1LC-LC-08
85
MZ2STII-STII-30 80
ML2STII-STII-10 88
ML2LC-MJ-08
95
MS1LC-LC-10
85
MZ2STII-STII-40 80
ML2STII-STII-15 88
ML2LC-MJ-10
95
MS1LC-LC-100
86
MZ2STII-STII-50 80
ML2STII-STII-20 88
ML2LC-MJ-15
95
MS1LC-LC-15
85
MZ2LC-LC-04
80
ML2STII-STII-25 88
ML2LC-MJ-30
95
MS1LC-LC-20
85
MZ2LC-LC-06
80
ML2STII-MJ-04
96
ML2LC-SC-15
92
MS1LC-LC-25
85
MZ2LC-LC-10
80
ML2STII-MJ-06
96
ML2LC-SC-4
92
MS1LC-LC-30
85
MZ2LC-LC-20
80
ML2STII-MJ-08
96
ML2LC-SC-6
92
MS1LC-LC-35
85
MZ2LC-LC-30
80
ML2STII-MJ-10
96
ML2LC-ST-10
92
MS1LC-LC-40
86
MZ2LC-LC-40
80
ML2STII-MJ-30
96
ML2LC-ST-15
92
MS1LC-LC-50
86
MZ2LC-LC-50
80
ML2STII-SC-02
93
ML2LC-ST-30
92
MS1LC-LC-75
86
MZ2LC-MJ-04
82
ML2STII-SC-04
93
ML2LC-ST-4
92
MS2LC-LC-04
86
MZ2LC-MJ-06
82
ML2STII-SC-06
93
ML2LC-ST-6
92
MS2LC-LC-05
86
MZ2LC-MJ-10
82
ML2STII-SC-08
93
ML2SC-MJ-04
95
MS2LC-LC-06
86
MZ2LC-MJ-20
82
ML2STII-SC-10
93
ML2SC-MJ-06
95
MS2LC-LC-08
86
MZ2LC-MJ-30
82
ML2STII-SC-100 93
ML2SC-MJ-08
95
MS2LC-LC-10
86
MZ2LC-MJ-40
82
ML2STII-SC-15
93
ML2SC-MJ-10
95
MS2LC-LC-100
86
MZ2LC-MJ-50
82
ML2STII-SC-20
93
ML2SC-MJ-15
95
MS2LC-LC-15
86
MZ2LC-SC-04
82
ML2STII-SC-25
93
ML2SC-MJ-20
95
MS2LC-LC-20
86
MZ2LC-SC-06
82
ML2STII-SC-30
93
ML2SC-MJ-25
95
MS2LC-LC-25
86
MZ2LC-SC-10
82
ML2STII-SC-35
93
ML2SC-SC-02
91
MS2LC-LC-30
86
MZ2LC-SC-20
82
ML2STII-SC-40
93
ML2SC-SC-04
91
MS2LC-LC-35
86
MZ2LC-SC-30
82
ML2STII-SC-50
93
ML2SC-SC-05
91
MS2LC-LC-40
86
MZ2LC-SC-40
82
ML2STII-SC-75
93
ML2SC-SC-10
91
MS2LC-LC-50
86
MZ2LC-SC-50
82
ML2LC-LC-02
85
ML2SC-SC-15
91
MS2LC-LC-75
86
MZ2LC-STII-04
82
ML2LC-LC-04
85
ML2SC-SC-20
91
MS2LC-SC-10
92
MZ2LC-STII-06
82
ML2LC-LC-05
85
ML2SC-SC-25
91
MS2LC-SC-20
92
MZ2LC-STII-10
82
ML2LC-LC-06
85
MPS100E - 003
162
MTDL80-262
176
MZ2LC-STII-20
82
ML2LC-LC-08
85
MPS100E - 112
162
Music Wire
246
MZ2LC-STII-30
82
ML2LC-LC-10
85
MPS100E - 123
162
Music Wire
247
MZ2LC-STII-40
82
ML2LC-LC-100
85
MPS100E - 226
162
Music Wire
248
MZ2LC-STII-50
82
ML2LC-LC-15
85
MPS100E - 246
162
Music Wire
249
MZ2SC-SC-04
82
COMCODE
Product Index
Product
Page
Contents page
Product
Page
MZ2SC-SC-06
82
Primer
247
Polishing Tool
MZ2SC-SC-10
82
Primer
249
MZ2SC-SC-20
82
Primer
250
MZ2SC-SC-30
82
Primer
MZ2SC-SC-40
82
MZ2SC-SC-50
82
P1000A-Z-125
187
P1001A-Z-125
186
P1001A-Z-
Page
ZWBA1-003
178
Tool (LC)
241
ZWBA1-246
178
254
TYPE A
257
ZWBA1-262
178
Primer
255
Type A
ZWBA1-270
178
PRIMER
256
Polishing Paper 246
ZWBC1-003
178
R2100A
135
Type A
ZWBC1-246
178
R2200
135
Polishing Paper 247
ZWBC1-262
178
R2300
135
Type A
ZWBC1-270
178
263
Polishing Paper 248
186
Rosin Bag Rubber Polishing
P1001D-Z-125
188
Pad
P1002A-Z-125
187
Rubber Polishing Pad
187
Rubber
P1101A-Z-125
186
Polishing Pad
P2020C-C-125
194
Rubber Polishing Pad
125/100
194
SC Curing
P2020C-Z-125
194
Fixture
P2020C-Z-
Product
T2001A1 Polishing
188
P2020C-C-
244
213
P1001C-Z-125
125/100
Page
Z3B1
125/100
P1002A-Z-
Product
Type A 239
Polishing Paper 249 Type A
240
Polishing Paper 250 Type A Polishing
241
Paper
251
Type F 242
Polishing Paper 248 Type F
239
SC Curring
Polishing Paper 249 Type F
125/100
194
Fixture
240
Polishing Paper 250
P2040
134
Scissors
239
Type F
P2070A-Z-125
195
Scissors
240
Polishing Paper 251
P2070A-Z-125
195
Scissors
241
Type F Polishing
P2080
134
Six-Unit Splitter
P3020A-Z-125
194
D-181781
P3070A-Z-125
195
SPCR-
P6000A-Z-125
191
110UHS20BAR.
P6001A-Z-125
191
063X1
P6200A-Z-126
191
Stripping Tool
P6201A-Z-126
191
(R4366)
PM2150-24
134
Stripping Tool
PM2150-48
134
(R4366)
PM2160GS-24
133
Stripping Tool
PM2160GS-48
133
(R4366)
241
Paper (purple)
PM2250B-24
133
Syringes
263
Wire
PM2250B-24
134
SYSTIMAX 4
PM2250B-48
133
TESTER
PM2250B-48
134
T2001A
Paper (yellow) 263
253
Type F Polishing 254
COMCODE
Paper (yellow) Type F Polishing 106
Paper (yellow)
255
Type J Polishing 239
Paper (purple)
253
Type J Polishing 240
Paper (purple)
254
Type J Polishing
267
255
Marker Book
263
Z3A2
212
Z3A3
212
289
290
Appendix Chapter
11
291
Appendix Contents
Click Here Main Menu
Glossary
295
Warranty
320
Abbreviations
322
Avaya Connectivity Solutions EMEA Representative Offices
292
325
GLOSSARY
Glossary
Glossary Contents Page
See Micron (µm).
10BASE-FL
An implementation of the Institute of Electrical and Electronic Engineers (IEEE) Ethernet standard on 62.5/125-µm fibre optic cable, a baseband medium of 10 Mb/s.
10BASE-T
An implementation of the Institute of Electrical and Electronic Engineers (IEEE) Ethernet standard on 24-AWG, unshielded, twisted-pair wiring, a baseband medium of 10 Mb/s.
10BASE2
An implementation of the Institute of Electrical and Electronic Engineers (IEEE) Ethernet standard on thin coaxial cable, a baseband medium of 10 Mb/s. The maximum segment length is just under 200m (656ft).
10BASE5
An implementation of the Institute of Electrical and Electronic Engineers (IEEE) Ethernet standard on twinaxial cable, a baseband medium of 10 Mb/s. The maximum segment length is 500m (1,640ft).
100BASE-T
Official project name for 100 Mb/s Fast Ethernet.
100BASE-T4
100 Mb/s Fast Ethernet using 4-pair Category 3 cable.
100BASE-TX
100 Mb/s Fast Ethernet using 2-pair Category 5 cable.
100VG-ANY LAN
100 Mb/s LAN using Demand Priority Protocol originally developed by Hewlett Packard and AT&T for Category 3 cable.
1000BASE-T
A specification for Gigabit Ethernet over copper wire (IEEE Standard 802.3ab). The standard defines 1 Gb/s data transfer over distances of up to 100 metres using four pairs of Category 5e balanced copper cabling and a 5-level coding scheme.
1000BASE-TX
A specification for Gigabit Ethernet over copper wire (TIA/EIA). The standard defines 1 Gb/s data transfer over distances of up to 100 metres using four pairs of Category 6 balanced copper cabling.
1000BASE-LX
A specification for Gigabit Ethernet over fibre optic cable (IEEE Standard 802.3z) at 1300nm wavelength.
1000BASE-SX
A specification for Gigabit Ethernet over fibre optic cable (IEEE Standard 802.3z) at 850nm wavelength.
10 Gigabit Ethernet
The IEEE has initiated work on the specification of 10 Gigabit Ethernet over optical fibre cabling. The standard is planned for completion in 2001 or early 2002, with specifications for multimode and singlemode fibre.
802.3
Defined by the Institute of Electrical and Electronic Engineers (IEEE), these standards govern the use of the Carrier Sense Multiple Access/Collision Detection (CSMA/CD) network access method used by Ethernet networks.
802.5
Defined by the Institute of Electrical and Electronics Engineers (IEEE), these standards govern the use of the token ring network access method.
802.11
Defined by the Institute of Electrical and Electronics Engineers (IEEE), these standards govern the use of wireless LANs.
A
See Ampere (A).
GLOSSARY
µm
293
GLOSSARY
GLOSSARY
Glossary (contd)
294
Glossary Contents Page
Adapter
A device that (1) enables different sizes or types of plugs to mate with one another or to fit into an information outlet, (2) provides for the rearrangement of leads, (3) allows large cables with numerous wires to fan out into smaller groups of wires, or (4) makes interconnections between cables.
Ad Hoc Cabling
Cabling scheme where different types of cabling components from different vendors are linked together to form a cabling system.
Administration Point
A location at which communications circuits are administered; that is, rearranged or rerouted by means of cross connections, interconnection, or information outlets.
Administration Subsystem
The part of a premises distribution system that includes the distribution hardware components where you can add or rearrange circuits. These components include cross-connects, interconnects, telecommunication outlets, and their associated patch cords and plugs. Also called “administration points.” See also Cross-Connect and Telecommunications Outlet (TO).
American National Standards Institute (ANSI)
Organisation responsible for the definition and maintenance of the Fibre Distributed Data Interface (FDDI) standard. ANSI is the principal group in the United States for defining standards. ANSI represents the U.S. in the International Standards Organisation (ISO).
American Wire Gauge (AWG)
The standard gauge for measuring the diameter of copper, aluminum, and other conductors.
Ampere (A)
A standard unit of current. One ampere of current is produced by one coulomb of charge passing a point in one second.
Analogue Signal
A signal that represents information in a continuously variable and directly measurable physical quantity, such as voltage. Shaped like a wave, analogue signals, such as those transmitted over a telephone channel, vary in both frequency and amplitude proportionate to the voice or other signals initiating them. See also Digital Signal.
Analogue Transmission
A method of signal transmission in which the shape of the signal is a continuously variable and directly measurable physical quantity such as voltage.
ANSI
See American National Standards Institute (ANSI).
Application
A system, with its associated transmission method which is supported by telecommunications cabling.
Application Layer
The uppermost layer (layer 7) of the open systems interconnection (OSI) model. This layer is concerned with support to the user application and is responsible for managing the communication between applications, e.g. Email, File transfer, etc.
ASCII
The American Standard Code for Information Interchange. A widelyused 7 or 8-bit binary code used to represent alphabetic and numeric characters in computer understandable form.
Asynchronous
Two or more signals sourced from independent clocks, therefore having different frequency and phase relations.
Asynchronous Data Transfer
A method of data transfer in which each alphabetic or numeric character (represented by 7 or 8 bits) is preceded by ‘start’ and ‘stop’ bits to delineate the 7/8 bit pattern from the ideal pattern which otherwise occupies the (digital) transmission medium.
GLOSSARY
Glossary (contd)
Glossary Contents Page
A high speed cell-based switching and multiplexing technology based on segmentation of voice, data and video into fixed packets (cells). These cells are transferred along switched paths and are not received on a regular basis (hence the term asynchronous).
Asynchronous Transmission
A data transmission technique controlled by start and stop bits at each end of a character and characterised by an undetermined time interval between characters.
ATM
See Asynchronous Transfer Mode.
Attenuation
The effect of signal reduction, experienced with accumulating line length or distance of radio transmission.
AWG
See American Wire Gauge (AWG).
Backbone(s)
The part of a premises distribution system that includes a main cable route and facilities for supporting the cable from the equipment room to the upper floors, or along the same floor to the wiring closets.
Backbone/Riser Closet
See Telecommunications Closet/Room.
Backbone/Riser Subsystem
See Riser Backbone Subsystem.
Balanced Circuit
A circuit where equal and opposite signals are generated and sent on to two conductors. The better the balance of a circuit, the lesser is its emissions and the greater is its noise immunity (hence the better is its EMC performance).
Balanced Twisted Pair Cable
A cable consisting of one or more metallic symmetrical cable elements (twisted pairs or quads).
Balun
A device for matching impedance between a balanced to unbalanced line, usually twisted-pair and coaxial cable.
Bandwidth
The range of frequencies that can be used for transmitting information on a channel. It indicates the transmission-carrying capacity of a channel. Thus, the larger the bandwidth, the greater the amount of information that can pass through the circuit. Measured in Hertz or b/s or MHz.km (for fibre).
Baseband
A network in which the entire bandwidth of the transmission medium is used as a single digital signal. Unlike broadband, no modulation techniques are used.
Basic Rate Interface (BRI)
The simplest form of network access available on the ISDN (integrated services digital network). The BRI comprises of 2B + D channels for carriage of signaling and user information.
Bend Radius
The radius of curvature that fibre or copper can bend without breaking or causing excessive loss.
Bit Error Rate (BER)
A measure of quality of a digital transmission line, either quoted as a percentage, or more usually as a ratio, typically 1 error in 10E8 or 10E9 bits carried. The lower the number of errors, the better the quality of the line.
BNC Connector
The connector type used on many types of coaxial data communication equipment.
Bonding
The connecting together of all building and equipment electrical grounds to eliminate differences in electrical ground potentials.
GLOSSARY
Asynchronous Transfer Mode (ATM)
295
GLOSSARY
GLOSSARY
Glossary (contd)
296
Glossary Contents Page
BRI
See Basic Rate Interface (BRI).
Bridge(s)
A device used to link two subnetworks using the same communications method and sometimes the same kind of transmission medium.
Broadband
A network in which the bandwidth can be shared by multiple simultaneous signals that are encoded with radio frequency modulations.
Building Backbone Cable
A cable that connects the building distributor to a floor distributor. Building backbone cables may also connect floor distributors in the same building.
Building Distributor
A distributor in which the building backbone cable(s) terminate(s) and at which connections to the campus backbone cable(s) may be made.
Building Entrance Facility
A facility that provides all necessary mechanical and electrical services, that complies with all relevant regulations, for the entry of telecommunications cables into a building.
BUS
Consists of a common transmission path with a number of nodes attached to it. Sometimes referred to as linear network topology.
Bus Topology
A local area network (LAN) topology in which endpoints connect to a single wire or fibre, or set of wires or fibres, at any point. The Ethernet LAN is one example.
Cable Fill
The ratio of cable installed into a conduit/trunking against the theoretical maximum capacity of the conduit/trunking.
Cable Rack
The vertical or horizontal supports, usually made of aluminium or steel, that are attached to a ceiling or wall. Cables are laid in and fastened to the rack. Sometimes called trays.
Cable Routing Diagram
A detailed drawing showing the layout of the cable routes.
Cabling
A system of telecommunications cables, cords and connecting hardware that can support the connection of information technology equipment.
CAD/CAM
Computer-Aided Design/Computer-Aided Manufacturing.
Campus
A premises containing more than one building adjacent or near to one another.
Campus Backbone Cable
The communications cable that is part of the Campus Backbone Subsystem and runs between buildings. There are four methods of installing campus backbone cable: in-conduit (in underground conduit), direct-buried (in trenches), aerial (on poles), and in-tunnel (in stream tunnels). A cable that connects the campus distributor to the building backbone distributor(s). Campus backbone cables may also connect building cabling distributors directly.
Campus Cable Entrance
The point at which Campus Backbone Subsystem cabling (aerial, direct-buried, or underground) enters a building.
Capacitance
The property in a system of conductors and dielectrics that permits the storage of electrically separated charges whenever a difference in potential exists between the conductors. Capacitance is undesirable in copper wire cable because it interferes with signals travelling on the wire by opposing the desired flow of current.
GLOSSARY
Glossary (contd)
Carrier Sense Multiple Access with Collision Avoidance (CSMA/CA)
Glossary Contents Page
Network access method using contention similar to Carrier Sense Multiple Access/Collision Detection (CSMA/CD) used by LocalTalk networks. Unlike CSMA/CD, in this method the sending node requests permission to transmit. It defines protocols for user or applications programs.
Carrier Sense Multiple Access/ Network access method in which nodes contend for the right to send Collision Detection (CSMA/CD) data. If two or more nodes attempt to transmit at the same time, they abort their transmission until a random time period of microseconds has transpired and then attempts to resend. For cable and connecting hardware products with transmission characteristics specified to 16 MHz, typically used to support digital transmission of 10 Mb/s.
Category 5
For cable and connecting hardware products with transmission characteristics specified to 100 MHz, typically used to support digital transmission of 100 Mb/s and above.
Category 5e
This is an enhanced version of Category 5, with additional parameters specified to enable parallel transmission with full duplex across the four pairs. Enhanced Category 5 specifications for cable and connecting hardware products with transmission characteristics specified to 100 MHz, intended to support digital transmission of 1000 Mb/s.
Category 6
For cable and connecting hardware products with transmission characteristics specified to 250 MHz, used to support digital transmission of 1 Gb/s and above.
Category 7
For cable and connecting hardware products with transmission characteristics specified to 600 MHz. Category 7 is a cable standard only and will require a new connector standard to fully exploit transmission at the above frequencies.
Ceiling Distribution
Distribution system that uses the space between the false or suspended ceiling and the structural ceiling for housing horizontal cable routes.
Cell Relay
A fast packet switching technique which uses fixed-length cells. Generic name for ATM, SMDS and BISDN.
CENELEC
European committee for electrotechnical standardisation.
CENELEC EN 50173
The European standard for generic cabling for customer premises.
CENELEC EN 50174
A proposed European cabling systems planning & installation standard developed by CENELEC.
Central Processing Unit (CPU)
A personal computer’s (PC’s) primary microprocessor chip.
Channel
The end-to-end transmission path connecting any two pieces of application-specific equipment. Equipment cables and work area cables are included in the channel.
Characteristic Impedance
A frequency-dependent resistance that quantifies the complex opposition to current flow offered by a transmission line.
Chromatic Dispersion
Chromatic dispersion describes the tendency for different wave-
GLOSSARY
Category 3
297
GLOSSARY
Glossary (contd)
Glossary Contents Page
lengths to travel at different speeds in a fibre. If operated at wavelengths where chromatic dispersion is high, optical pulses tend to temporarily broaden, leading to intersymbol interference, which can produce an unacceptable bit error rate. The relocation of an individual or a group of individuals within a building such that the workspace or services to the workspace require change.
Circuit
A two-way communications path between electronic devices.
Cladding
The low refractive index material that surrounds the core of an optical fibre, usually pure silica.
Client
A node that requests network services from a server.
Client-Server
A technique by which processing can be distributed between nodes requesting information (clients) and those maintaining data (servers).
Closet
SYSTIMAX® SCS location for hardware, conduits, power panels, and electronics such as multiplexers and concentrators.
Coating
A protective layer of material over the cladding of an optical fibre.
Coaxial Cable (Coax)
A cable with a centre conductor surrounded by a thick insulation, surrounded by an outer conductor made of metal braid. An outer jacket insulation is optional.
Collapsed Backbone
This architecture is a backbone topology where wiring concentrators located at floor levels are attached in a star configuration to a central high performance switching concentrator.
Composite Cable
A cable construction technique that combines multiple cables or media in a single overjacket.
Conductor
A medium such as copper wire that can carry electrical current.
Conduit
A pipe, usually metal, that runs underground from floor to floor, or along a floor or ceiling to protect cables. In the Riser Backbone Subsystem when riser telecommunications closets are not aligned, conduit is used to protect cable and provide the means for pulling cable from floor to floor. In the Horizontal Subsystem, conduit may be used between a telecommunications closet and an information outlet in an office or other room. Conduit is also used for in-conduit campus distribution, where it is run underground between buildings and intermediate manholes and is made of plastic encased in concrete. Multiduct, clay-tile conduit may also be used.
Connecting Block
A flame-retardant plastic block containing metal wiring terminal (quick clips) that establishes an electrically tight connection between the cable and the cross-connect wire.
Connecting Hardware
See Cross-Connect.
Connector
A device that allows you physically to connect and disconnect copper wires or fibres to cable equipment or to other wires or fibres. Copper wire and fibre optic connectors must often join transmission media to equipment or cross-connects.
Consolidation Point
An interconnection point in horizontal cabling, typically used to support the re-arrangement of furniture cloisters.
GLOSSARY
Churn
298
GLOSSARY
Glossary (contd)
Glossary Contents Page
The central transmission area of a fibre. The core always has a refractive index higher than that of the cladding.
Cords
A short length of copper wire or fibre optic cable with connectors on each end. Used to connect equipment to cabling, or to connect cabling segments (cross-connection).
Coulomb (C)
A quantity of electricity transferred by a current of one ampere in one second.
CPU
See Central Processing Unit (CPU)
CRC
See Cyclic Redundancy Check (CRC).
Cross-Connect
SYSTIMAX® SCS component where communication circuits are administered (that is, added or rearranged using jumper wire or patch cords). In 110 Connector Systems, Hook-Up Wire or patch cords are used to make circuit connections. In fibre optic connector systems, fibre optic patch cords are used. The cross-connect is located in an equipment room or telecommunications closet. See also Jumper Wire and Patch Cord.
Cross-Connect Field
Copper wire or fibre terminations grouped to provide cross-connect capability. The groups are identified by colour-coded sections of back boards mounted on the wall in equipment rooms or telecommunications closets, or by designation strips or labels placed on the wiring block or unit. The colour coding identifies the type of circuit that terminates at the field.
Crosstalk
An electromagnetic coupling between two physically isolated circuits in a system. This coupling causes a signal on one circuit to induce a noise voltage on adjacent circuits, thereby causing signal interference.
CSA
Canadian Standards Association.
CSMA/CA
See Carrier Sense Multiple Access with Collision Avoidance (CSMA/CA).
CSMA/CD
See Carrier Sense Multiple Access/Collision Detection (CSMA/CD).
Customer Premises Equipment (CPE)
Customer owned equipment used to terminate or process information from the public network e.g. Multiplexed or PABX.
Cut-Down
A method of securing a wire to a wiring terminal. The insulated wire is placed in the terminal groove and pushed down with a special tool. As the wire is seated, the terminal cuts through the insulation to make an electrical connection, and the spring-loaded blade of the tool trims the wire flush with the terminal. Also called punch-down.
GLOSSARY
Core
Cyclic Redundancy Check (CRC) A coded sequence of information allowing error checking and correction. Data Communications Equipment (DCE)
General terminology for data communications equipment such as modems. A device that terminates a data communications session and provides encoding or conversion if necessary. See also Data Terminating Equipment (DTE).
Data Link Layer
Layer 2 of the Open Systems Interconnect (OSI) model; it defines protocols governing data packets, and transmission into and out of each node.
299
GLOSSARY
GLOSSARY
Glossary (contd)
300
Glossary Contents Page
Data Terminating Equipment (DTE)
The term used to describe any type of computer or other equipment, when connected to a data communications network.
dB
See Decibel (dB).
dB/km
See Decibel/kilometre (dB/km).
DB9
A standardised connector with nine pins for token ring and serial connections.
DB15
A standardised connector with 15 pins for Ethernet transceivers.
DB25
A standardised connector with 25 pins for parallel or serial connections.
DCE
See Data Communications Equipment (DCE).
Decibel (dB)
A unit used to measure relative increase or decrease in power, voltage or current, using a logarithmic scale.
Decibel/kilometre (dB/km)
A unit of measurement for fibre optic attenuation.
Delay Skew
Delay Skew is the difference in propagation delay between any two pairs within the same cable sheath.
Dielectric
A nonconducting or insulating material that resists passage of electric current.
Dielectric Cable
A nonconducting cable, such as fibre optic cable, without metallic members.
Dielectric Constant
The ratio of the capacitance of the insulated wire to that of the same wire uninsulated in air.
Dielectric Strength
A measure of the maximum voltage that the insulation of a particular cable can withstand without breakdown.
Digital Signal
A signal that represents information by a series of fixed, encoded, rectangular pulses, usually consisting of two possible voltage levels. Each voltage level indicates one of two possible values or logic states, such as on or off, open or closed, true or false. See also Analogue Signal.
Digital Transmission
A technique in which all information is converted into binary digits for transmission.
Dispersion
The tendency of a beam of light to spread out and loose its focus.
Distributor
The term used for the functions of a collection of components (for example, patch panels, patch cords) used to connect cables.
DIW
See Network Communications Cable (NCC) and Twisted Pair.
DTE
See Data Terminating Equipment (DTE) and also Data Communications Equipment (DCE).
Dual-Fibre Cable
A type of fibre optic cable that has two single-fibre cables enclosed in a jacket of extruded plastic.
Ducts
The main feeder channels in which communication cable is routed between buildings in a campus environment. See also Campus Backbone Cable.
GLOSSARY
Glossary (contd)
Glossary Contents Page
EIA
See Electronics Industries Association (EIA).
EIA/TIA
North American Standards organisation.
EIA/TIA 568B
North American commercial building telecommunications wiring standard.
EIA/TIA 569A
North American commercial building standard for telecommunications pathways and spaces. Its purpose is to standardise specific design and construction practices within and between buildings which are in support of telecommunications media and equipment.
EIA/TIA 606
North American administration standard for the telecommunications infrastructure of commercial buildings. Its purpose is to provide guidelines for a uniform administration scheme for the cabling infrastructure.
Electromagnetic Compatibility (EMC)
The ability of a system, equipment or device to operate satisfactorily in its environment without introducing unacceptable electromagnetic disturbance, or being affected by that environment.
Electronics Industries Association North American Electronics Association. Electric and magnetic fields (commonly referred to as emissions) generated by equipment or system.
Electromagnetic Interference
The interference in signal transmission or reception caused by the radiation of electric and magnetic fields (EMI).
ELFEXT
See Equal Level Far End Crosstalk.
EMC
See Electromagnetic Compatibility.
EMI
See Electromagnetic Interference.
EN 50173
The European standard for generic cabling for customer premises.
EN 50174
A proposed European cabling systems planning & installation standard developed by CENELEC.
Equal Level Far End Crosstalk (ELFEXT)
Is the same as FEXT, except that the coupled signal at the remote end is relative to the attenuated signal at the remote end on the pair the signal was applied to at the local end.
Equipment Cable
A cable connecting equipment to a distributor.
Equipment Room
The room in which voice and data common equipment (for example, a DEFINITY® switch) is housed, protected, and maintained, and where circuit administration is done using the trunk and distribution cross-connects.
Equipment Subsystem
The part of a premises distribution system that includes the cable and distribution components in an equipment room and that interconnects system-common equipment, other associated equipment, and cross-connects.
Ethernet
The common name for the most widely used local area network (LAN), generally conforming to the Institute of Electrical and Electronic Engineers (IEEE) 802.3 Standard.
GLOSSARY
Electromagnetic Flux
301
GLOSSARY
GLOSSARY
Glossary (contd)
302
Glossary Contents Page
Farad (F)
The standard unit of capacitance.
Far End Crosstalk (FEXT)
Refers to the undesired coupling of signals from the transmit pair onto the receive pair at the other (=far) end. FEXT isolation is also expressed in dB. For some applications this is an important parameter, for most applications however, the NEXT values are more important.
Fast Ethernet
A 100 Mb/s LAN Based On CSMA/CD Protocol. See 100BASE-T.
Federal Communications Commission (FCC)
A board of five commissioners, appointed by the President, that regulates all electronic communications systems originating in the United States, including telephone systems.
FEXT
See Far End Crosstalk.
FDDI
See Fibre Distributed Data Interface.
Fibre
Any filament or fibre, made of dielectric materials, that guides light. See also Fibre Optics.
Fibre Channel
This is an ANSI standard describing point to point and switched point to point physical interface, transmission protocol, signaling protocol, services and command set mapping of a high performance serial link for uses between mainframe computers and computer peripherals.
Fibre Distributed Data Interface (FDDI)
An American National Standards Institute (ANSI) standard for a fibre-based token ring physical and data link protocol that operates at a 100 Mb/s data transfer rate.
Fibre Optic
A fibre optic cable in which individual optical fibres are formed into a cable for primary use inside a building.
Fibre Optics
The technique of conveying lights or images through glass or plastic fibres. Incoherent fibre optics will transmit light but not an image; coherent fibre optics will transmit both and should actually be called “aligned fibre optics” because the fibres are all the same length and are held in a constant spatial relationship.
Fibre Optic Building Cable (LGBC)
A fibre optic cable in which individual optical fibres are formed into a cable for primary use in a side building.
Fibre Optic Cable
A transmission medium consisting of a core of glass or plastic surrounded by a protective cladding, strengthening material, and outer jacket. Signals are transmitted as light pulses, introduced into the fibre by a light transmitter (either a laser or light-emitting diode [LED]). Some of the advantages offered by fibre optic cable are low data loss, high-speed transmission, large bandwidth, small physical size, light weight, and freedom from electromagnetic interference and grounding problems.
Fibre Optic Connectors
Connectors designed to connect and disconnect either single or multiple optical fibres repeatedly. Fibre optic connectors are used to connect fibre cable to equipment and interconnect cables.
Fibre Optic Cross-Connection
Fibre optic apparatus for terminating cable in couplings. Designed for high-density cross-connection fields, the apparatus can terminate up to 72 fibres on each shelf, with up to nine shelves in a bay frame. Single shelves can also be wall mounted. Cross-connections are handled with fibre optic patch cords. See also Patch Cord.
GLOSSARY
Glossary (contd)
Glossary Contents Page
Fibre Optic Cross-Connect (LGX) A component of fibre optic cross-connect hardware. This component Distribution System accommodates 24-216 fibre terminations. Also referred to as an LGX or shelf or frame. An interconnection unit used for circuit administration and built from modular cabinets. It provides interconnection for individual optical fibres but, unlike the fibre optic cross-connect panel, it does not use patch cords or jumpers. The fibre optic interconnect provides some capability for routing and rerouting circuits, but is usually used where circuit rearrangements are infrequent.
Fibre Optic Interconnection Unit (LIU)
A component of fibre pitch cross-connect hardware. This component accommodates 12, 24 or 48-fibre terminations. Also referred to as an LIU.
Fibre Optic Splice
A fibre optic cable splice is used to join together 2 or 24 fibre optic cable ends, permanently.
Field
See Cross-Connect Field.
File Server
A computer that stores data centrally for network users and manages access to that data. File servers can be dedicated so that no processes other than network management can be executed while the network is available, or nondedicated so that standard user applications can be run while the network is available.
Fire Walls
Walls that go from structural floor to structural ceiling and, therefore, help prevent fire from spreading from one area to another.
Flood Wiring
The concept of wiring for future growth, by providing full coverage of information outlets.
Floor Distributor
The distributor used to connect between the horizontal cable and other cabling subsystems or equipment (see telecommunications closet).
Foil Screened Twisted Pair Cable (FTP)
A cable that uses a metallic Foil to surround the conductors in a Twisted Pair cable.
Frame
A metallic structure for hanging switch hardware.
Frequency
The number of cycles completed by a signal in one second: measured in Hertz (Hz).
FTP
See Foil Screened Twisting Pair Cable.
Full Duplex
In contrast to half-duplex devices, full duplex ones allow permanent, simultaneous two-way transmission of information, without interaction or interference of receive and transmit signals.
Full Duplex Ethernet
Full Duplex Ethernet will allow nodes to transmit and receive data at the same time, bringing aggregate throughput to 20 Mb/s. The CSMA/CD protocol may have to be disabled for the full duplex mechanism to function.
Gauge
A measure of a conducting wire’s physical size, usually referred to as AWG (American Wire Gauge). See also American Wire Gauge (AWG).
Generic Cabling
A structured telecommunications cabling system, capable of supporting a wide range of applications. Generic cabling can be installed without prior knowledge of the required applications. Application-specific hardware is not a part of generic cabling.
GLOSSARY
Fibre Optic Interconnect
303
GLOSSARY
GLOSSARY
Glossary (contd)
Graded-Index Fibre
An optical fibre with a refractive index that gets progressively lower away from the axis. This causes the light rays to be continually refocused by refraction in the core. It bends the rays inwards and allows them to travel faster in the lower index of refraction regions. This type of fibre provides high bandwidth capabilities.
Ground
A conducting connection, intentional or accidental, between a circuit or equipment and the earth.
H
See Henry.
Half Duplex
A telecommunications device allowing two-way transmission of signals or other information, but only in one direction at a time. Thus a half-duplex device cannot simultaneously transmit and receive, though interspersed bursts in each direction are possible.
Henry (H)
The standard unit of inductance. The inductance of a current is a one Henry when a current variation of one ampere per second induces one volt.
Hertz (Hz)
The standard unit of frequency; equal to one cycle per second.
Horizontal Cable
A cable connecting the floor distributor to the telecommunications outlet(s).
Horizontal Length (HL)
The cable distance from the information outlet to the blue field of the cross-connect. In SYSTIMAX SCS, this is referred to as the Horizontal Subsystem.
Horizontal Runs
The part of the premises distribution system installed on one floor that includes the cabling and distribution components connecting the riser backbone or equipment wiring to the information outlet. See Horizontal Subsystem.
Horizontal Subsystem
The part of a premises distribution system installed on one floor that includes the cabling and distribution components connecting the Riser Backbone Subsystem to the information outlet via cross-connect components of the Administration Subsystem.
Hub(S)
A concentrator or repeater in a star topology at which node connections meet.
Hybrid Cable
An assembly of two or more different types of cable units, cables or categories covered by an overall sheath. It may be covered by an overall shield.
Hz
See Hertz (Hz).
IBM
International Business Machines Corporation.
IEC 60332
The international standard covering fire performance of cables.
IEEE
Institute of Electrical and Electronic Engineers in the USA. This organisation is also involved in producing Local Area Network standards such as 10Base-T and Token Ring.
Individual Pair Screened
Where each twisted pair in one overall cable has its own screen.
InfiniBand Architecture
A high bandwidth switched network topology currently being developed for Storage Area Networks (SANS).
Insulation
A material having high resistance to the flow of electric current. Thin conducting wires are covered with colour-coded insulation for protection.
™
304
Glossary Contents Page
GLOSSARY
Glossary (contd)
Glossary Contents Page
The type of wire terminals that require no wire stripping; when the wire is correctly attached, its insulation is displaced (pierced) to form a connection.
Insulation Resistance
The measure of the ability of an insulation material to resist the flow of current through it; usually measured in Megohm-feet (Mµ-ft).
Integrated Services Digital Network (ISDN)
Integrated voice and data network based on digital communications technology and standards interfaces.
Intelligent Buildings
Buildings that maximise the efficiency of its occupants and allow effective management of resources with minimum life-time costs. (Source: European Intelligent Building Group).
Intercloset Cables
Cables that connect telecommunications closets.
Interconnect
A circuit administration point, other than a cross-connect or information outlet, that provides capability for routing and rerouting circuits. It does not use patch cords or jumpers. Typically it is a jack-and-plug device used in smaller distribution arrangements or to connect circuits in large cables to those in smaller cables.
Interface Cards
See Network Interface Cards.
Interference
A signal impairment caused by the interaction of another unwanted signal.
International Standards Organisation (ISO)
The organisation responsible for the Open Systems Interconnect (OSI) standards.
International Telegraphy and Telephone Consultative Committee (CCITT)
A standards organisation that, among numerous other activities, specialises in the electrical and functional characteristics of switching equipment. The CCITT sets standards for interfaces to ensure compatibility between data communications equipment (DCE) and data terminating equipment (DTE).
Interoperability
The ability to operate and exchange information in a heterogeneous network.
IO
Information Outlets (IO) is a connector where the horizontal cable terminates.
ISDN
See Integrated Services Digital Network (ISDN).
ISO
See International Standards Organisation (ISO).
ISO Seven Layer Model
A 7 layer hierarchical reference structure developed by the ISO for defining, specifying and relating communications protocol.
ISO/IEC IS 11801
An international standard for generic cabling for customer premises.
ISO/IEC 14763-1
The international standard for basic administration of generic cabling.
Isochronous Ethernet
This is part of the IEEE 802.9 integrated services LAN standard. It is an extension of 10Base-T which provides for the inclusion of a 6.144 Mb/s isochronous (real time and delay sensitive) data service in addition to the 10 Mb/s 10Base-T packet service. It will provide multimedia capability.
J
See Joule (J).
Jack
A receptacle used with a plug to make electrical contact between
GLOSSARY
Insulation Displacement
305
GLOSSARY
Glossary (contd)
Glossary Contents Page
GLOSSARY
communications circuits. Jacks and their associated plugs are used in a variety of connecting hardware applications including adapter, information outlets, and equipment connections. Jacket
The flexible covering of a cable, used to protect the colour-coded conductors inside.
Joule (J)
A unit of work or energy equal to 0.7375 foot-pounds.
Jumper
A cable unit or cable element without connectors used to make a connection on a cross-connect.
Jumper Wire
A short length of connectorised copper wire used to route a circuit by linking two cross-connect termination points.
Keying
A mechanical feature of a connector system which guarantees correct orientation of a connection or prevents the connection to a jack or optical fibre adapter of the same type intended for another purpose.
LAN
See Local Area Network (LAN).
Lays
The twists in twisted-pair cable. Two single wires are twisted together to form a pair; by varying the length of the twists, or lays, the potential for signal interference between pairs is reduced.
LC Connector
A high density connector for fibre optic applications used in both public and private networks. This high performance connector is available in both singlemode and multimode.
LIGHTPACK Cable
A cable core design that allows bundles of optical fibres in a cable core without central strength members.
Link
The transmission path between any two interfaces of generic cabling. It excludes equipment cables and work area cables.
Link Budget
Optical loss budget that determines the maximum distance allowable between station. Loss and dispersion factors are included.
LIU
See Fibre Optic Interconnection Unit (LIU).
Local Area Network (LAN)
A data communications network consisting of host computers or other equipment interconnected to terminal devices, such as personal computers, often via twisted-pair or coaxial cables. LANs allow users to share information and computer resources. Typically, a network is limited to a single premises.
MAC
See Media Access Control (MAC).
MAU
See Multistation Access Unit (MAU).
Mb
See Megabit (Mb).
MB
See Megabyte (MB).
Mbaud
See Megabaud (Mbaud).
Media Access Control (MAC)
Refers to both the media access portion of the Fibre Distributed Data Interface (FDDI) standard and the hardware and firmware (MAC entity) which implements this portion of the standard.
Media Interface Connector (MIC) A port connector also known as a “data connector” on a multistation access unit (MAU) in a token ring environment; also a dual-fibre connector for Fibre Distributed Data Interface (DFDI).
306
GLOSSARY
Glossary (contd)
Glossary Contents Page
Megabaud (Mbaud)
One million baud.
Megabit (Mb)
One million binary bits.
Megabyte (MB)
One million binary bytes.
MegaHertz (MHz)
One million Hertz (cycles per seconds).
MegaHertz-kilometre (MHz-km) A bandwidth-length product rating for multimode fibre. Bandwidth of the fibre is found by multiplying its length by its bandwidth-length product. See MegaHertz (MHz).
MHz-km
See MegaHertz-kilometre (MHz-km).
MIC
See Media Interface Connector (MIC).
Microfarad (µF)
One-millionth of a farad. This is the common unit for designating capacitance in electronics and communications.
Micron (µm)
A micrometer; one-millionth of a metre.
Mil
One-thousandth of an inch.
Modal Bandwidth
Bandwidth limited by modal dispersion inherent in multimode fibre optic cable.
Modal Dispersion
In multimode fibre the dispersion is caused by modal dispersion. Modal dispersion exists because the different light rays (modes) have a different path length, therefore rays entering at the same time will not leave the fibre at the same time at the other end of the fibre.
Modem
A modulator/demodulator unit used for data transmission. It converts digital data into analogue tones when transmitting over standard voice-grade telephone lines and reverses this process when receiving.
Multimedia
A means of conveying information with components in different media such as voice, music, text, graphics, image and video.
Multimode
Many light rays (modes) propagating through the fibre core.
Multimode Fibre
Optical fibres that have a large core and that permit nonaxial rays or modes to propagate through the core. 62.5 micron is the common standard core size for premises cabling systems.
Multiplexing
The process of combining multiple signals, usually by time-division multiplexing (TDM) on a high-frequency carrier, to optimise the use of available transmission media.
GLOSSARY
MHz
Multistation Access Unit (MAU) A concentrator or transceiver for attracting nodes to a transmission medium. Mutual Capacitance
The capacitance between two conductors when all other conductors, including the shield, are short-circuited to ground.
Nanometre (nn)
A unit of length in the metric system denoting one-billionth of a metre (10µm).
National Electrical Code (NEC)
A nationally recognised safety standard for the design, construction, and maintenance of electrical circuits. The NEC, sponsored by the National Fire Protection Association (NFPA), generally covers
307
GLOSSARY
Glossary (contd)
Glossary Contents Page
GLOSSARY
electrical power wiring within buildings.
308
NCC
See Network Communications Cable (NCC).
Near End Crosstalk (NEXT)
Refers to the undesired coupling of signals from the transmit pair onto the receive pair on the same (=near) end. NEXT isolation is expressed in dB and is a measure of how well the pairs in a cable are isolated from each other.
NEC
See National Electrical Code (NEC).
Network
The local and long-distance telecommunications capability provided by common carriers for switch and private line telecommunications services. A system of software and hardware connected in a manner to support data transmission.
Network Architecture
Network topology and design.
Network Communications Cable (NCC)
Network Communications Cable, often called NCC, is generally used in the Riser Backbone Subsystem in locations not involving plenums. The cable consists of 24-AWG, annealed-copper conductors insulated with colour-coded polyvinyl chloride (PVC) in twisted pairs, encased in an outer PVC jacket whose frictional properties permit it to be pulled in conduit without the aid of lubricants. This type of cabling used to be referred to as Direct Inside Wire (DIW).
Network Interface
The point of interconnection between building communications wiring and outside communications lines (telephone company facilities).
Network Interface Cards (NICs)
The piece of equipment that is installed into the expansion port of a personal computer and allows communication between the PC and the network.
Network Layer
The network layer is layer 3 of the OSI model. This layer sets up an end-to-end connection across a network determining which permutation of individual links to be used. Thus the network layer performs overall routing functions.
NEXT
See Near End Crosstalk.
nm
See Nanometre (nm).
Node(s)
A piece of communications equipment on the network.
Noise
The term used for spurious signals produced in a conductor by sources other than the transmitter to which it is connected. Noise can affect a legitimate signal to the extent that it is inaccurate or indecipherable when it reaches the receiver. The higher the speed of data transmission, the worse the effects of noise become.
Numerical Aperture
The size of the vertex angle of the largest core of rays that can enter or leave a multimode fibre optic system, multiplied by the refractive index of the medium in which the vertex of the core is located.
Ohm (W)
The standard unit of electrical resistance. One volt will cause one ampere of current to flow through one ohm of resistance.
Open System Interconnection (OSI)
A conceptual model specified by CCITT recommendations in the X200 series. The model describes the 7-layer process of communication
GLOSSARY
Glossary (contd)
Glossary Contents Page
between ‘co-operating’ computers. The model provides a standard for the development of communication protocols allowing for computers of different manufacturers to be interconnected. See Fibre Optic Connectors.
Optical Cross-Connection
See Fibre Optic Cross-Connection.
Optical Fibre
A transmission medium consisting of a core of glass or plastic surrounded by a protective cladding. Signals are transmitted as light pulses, introduced into the fibre by a light transmitter i.e. Laser or an LED.
Optical Interconnect
See Fibre Optic Interconnect.
Optical Splice
See Fibre Optic Splice.
Optical Time-Domain Reflectometre (OTDR)
An instrument that characterises cable loss by measuring the backscatter and reflecting of injected light as a function of time. It is useful for estimating attenuation and for locating splices, connections, and breaks.
OSI
See Open System Interconnection (OSI).
OTDR
See Optical Time-Domain Reflectometre (OTDR).
Outlets
A term used to describe the sockets provided in the work location of a Structured Cabling System. These are usually 8-pin modular sockets which can support a variety of services e.g. voice, video and data.
PABX
Private Automatic Branch Exchange. A private switching system that switches calls both internally within a building or premises and outside to the telephone network.
Packet-Switching
A type of exchange or network which conveys a string of information from origin to destination by cutting it up into a number of packets and carrying each independently. A packet-switched effect could be achieved by sending individual pages of a book through the post separately. The receiving device reassembles the message. Thus a direct connection between origin and destination does not exist at any point.
Pair
Two wires grouped (usually twisted) together and marked with reciprocal colour coding. See also Twisted Pair.
Patch Cord(s)
A short length of copper wire or fibre optic cable with connectors on each end used to join communications circuits as a cross-connect.
Patch Panel(s)
A cross-connect designed to accommodate the use of patch cords. It facilitates administration for moves and changes.
Pathway(s)
Designated cable routes and/or support structures in a false floor or ceiling.
PBX
See Private Branch Exchange (PBX).
PDS
See Premises Distribution System (PDS).
Peripheral(s)
Additions to a system, a resource e.g. printer, scanner, etc.
Permanent Link
The transmission path between two mated interfaces of generic cabling, excluding equipment cables, work area cables and
GLOSSARY
Optical Connectors
309
GLOSSARY
Glossary (contd)
Glossary Contents Page
GLOSSARY
cross-connections.
310
pF
See Picofarad (pF).
PHY
Physical layer of the Fibre Distributed Date Interface (FDDI) standard. Also used to refer to the actual hardware used to implement the physical layer (PHY entity).
Physical Layer
Layer 1 of the open systems interconnection (OSI) model. The physical layer protocol is the hardware and software in the line terminating device which converts the databits needed by the datalink layer into the electrical pulses, modem tones, optical signals or other means which will transmit the data.
Physical Topology
Physical cabling layout i.e. ring, bus, star wired etc.
Picofarad (pF)
A unit of capacitance used to designate capacitance unbalance between pairs or capacitance unbalance of the two wires of a pair to ground. One picofarad equals one trillionth of a farad.
Pin
A conductor on a plug or connector.
Plenum Cable
Cable specifically designed for use in a plenum, the space above a suspended ceiling used to circulate air back to the heating or cooling system in a building. Plenum cable has insulated conductors often jacketed with TEFLON or HALAR on copper and low smoke PVC on fibre optics to give them low flame-producing and low smokeproducing properties.
Plug
A device used for connecting wires to a jack. It is typically used on one or both ends of equipment cords or on wiring for interconnects or cross-connects.
PMD
Physical Medium Dependent part of the Fibre Distributed Data Interface (FDDI) standard. Determines the specifications for the fibre optic transmitters and receivers, fibre optic cable, fibre optic connectors, and fibre optic bypass switch.
Polyvinyl Chloride (PVC)
A flame-retardant thermoplastic insulation material that is commonly used in jacks or building cables. Both plenum are riser.
Port
The cable terminations in the equipment system at which various types of communications devices, switching equipment, and other devices are connected to the transmission network.
Ports
A computer interface capable of transmitting and or receiving information.
Power Sum
A method of testing and measuring crosstalk in multi-pair cables that accounts for the sum of crosstalk affecting a pair when all other pairs are active. This is the only method of specifying crosstalk performance that is suited to cables with more than four pairs.
Premises Distribution System (PDS)
The transmission network inside a building or group of buildings that connects various types of voice and data communication devices, switching equipment, and information management systems together, as well as to outside communications networks. It includes the cabling and distribution hardware components and facilities between the point where building wiring connects to the outside network lines, back to the voice and data terminals in to the office or
GLOSSARY
Glossary (contd)
Glossary Contents Page
other work locations. The system consists of all the transmissions media and electronics, administration points, connectors, adapters, plugs, and support hardware between the building’s side of the network interface and the terminal equipment required to make the system operational. Presentation Layer
Layer 6 of the OSI model. Responsible for identifying the syntax of the data being transmitted.
PRI
See Primary Rate Interface (PRI).
Primary Rate Interface (PRI)
ISDN standard interface comprising 23 B + 1 D Channel for North America, and 30 B + 1 D Channel for Europe. See Basic Rate Interface (BRI) and Integrated Services Digital Network (ISDN). The North American 1.544 Mb/s T1 (23B+D) or European 2.048 interface (PRI) Mb/s E1 (30B+D) ISDN interface is typically used to connect ISDN PBXs to the public ISDN. A private switching system usually serving an organisation, such as a business or government agency, and located on the customer’s premises. It switches calls both inside a building or premises and outside to the telephone network, and can sometimes also provide access to a computer from a data terminal.
Propagation Delay
A signal travelling from end to end of a simplex link is delayed in time by an amount equal to the length of cable divided by the velocity of propagation for that transmission medium. This delay is called Propagation Delay.
Proprietary Networks
Networks that are not designed, or installed to any standard based guidelines and do not relate specifically to any relevant standards.
Proprietary Systems
Systems that are not standards specific and therefore inoperable with standards based equipment.
Protocol(s)
A rule of procedure by which computer devices intercommunicate. Thus a protocol is the equivalent of a human language, with punctuation and grammatical rules.
Public Network Interface
A point of demarcation between public and private network. In many cases the public network interface is the point of connection between the network provider’s facilities and the customer premises cabling.
Pulling Tension
The amount of pull, measured in pounds, placed on a cable during installation.
Punch-Down
See Cut-Down.
PVC
See Polyvinyl Chloride (PVC).
Quad Fibre Cable
A type of fibre optic cable that has four single cables enclosed in an extruded jacket of polyvinyl chloride (PVC), with a rip cord for pulling back the jacket to access the fibres.
Raceway
Any distribution method designed for holding cables, e.g. conduit, metal or plastic trunking, cable trays, etc.
Rack
A vertical or horizontal open support, usually made of aluminium or steel, that is attached to a ceiling or wall. Cables are laid in and fastened to the rack.
Redundancy Risers
A fail-safe method of splitting and routing riser/ backbone cables via
GLOSSARY
Private Branch Exchange (PBX)
311
GLOSSARY
Glossary (contd)
Glossary Contents Page
two or more riser cores. Also known as diverse routing. The property of a conductor that determines the current produced by a given potential difference. It impedes the flow of current and results in the dissipation of power as heat. Resistance is measured in ohms.
Return Loss
The Channel Return Loss (RL) is a measure of the consistency of the impedance down the length of not just the cable, but also the connections and the patch cables.
RI
See Ring Out (RI).
Ribbon Fibre Cable
A cable that accommodates 1 to 12 ribbons, each ribbon having 12 fibres for a cable size range of 12 to 216 fibres. Ribbon cables are designed for use in large distribution systems where small cable size and high pulling strength are important.
Ribbon Riser Cable
An optical fibre, nonconductive, riser (OFNR)-rated premises cable containing optical fibres in ribbons.
Ring
A closed loop network topology.
Ring In (RI)
Port for connecting in multistation access units (MAUs) together.
Ring Out (RO)
Port for connecting out multistation access units (MAUs) together.
Riser(s)
The term used to describe a space utilised by backbone cabling to house communications cabling and other building services. This space should preferably be specified, or allowed for, at the time of the building design.
Riser Backbone Subsystem
The part of a premises distribution system that includes a main cable route and structure for supporting the cable from an equipment room (often in the building basement) to the upper floors, or along the same floor, where it is terminated on a cross-connect in a riser telecommunications closet, at the network interface, or at distribution components of the Campus Backbone Subsystem. The Riser Backbone Subsystem usually extends from an equipment room (often in a building’s basement) to the upper floors in a multistory building, or along the same floor in a low-wide building. It is terminated on a cross-connect in a riser telecommunications closet, at the network interface, or on the distribution components of the Campus Backbone Subsystem.
RO
See Ring Out (RO).
Router(s)
A router can be used to connect networks with similar protocols (802.5 token ring local area networks [LANs]) or dissimilar Open Systems Interconnection (OSI) model protocols (802.5 token ring LANs and X.25 packet-switching networks). Routers are more sophisticated than bridges and can be used to prevent some of the speed mismatch, security, and reliability problems that occur in large networks. An intermediate system between two or more networks capable of forwarding data packets at the network layer (layer 3).
Satellite Cabinet
Surface-mounted or flush-type wall cabinets for housing circuit administration hardware. Satellite cabinets, like satellite telecommunications closets, supplement riser telecommunications
GLOSSARY
Resistance
312
GLOSSARY
Glossary (contd)
Glossary Contents Page
closets by providing additional facilities for connecting horizontal cables from information outlets in user work areas. Sometimes referred to as a “satellite location”. A walk-in or shallow wall closet that supplements a riser telecommunications closet by providing additional facilities for connecting riser backbone cables to horizontal cables from information outlets. Also referred to as a “satellite location.” See also Telecommunications Closet/Room.
Scaleable
The ability to adapt to different bit rates.
Screened Cable
See Foil Screened Twisted Pair Cable.
Serial Communications
See Serial Data Transmission.
Serial Data Transmission
Data transmission between computer devices using only a single circuit path. Whole bytes of information (8 bits) are sent in sequential pattern. Compares with parallel transmission. Parallel transmission is often used internally within computing devices because of the higher processing speeds which are possible, but for long-distance telecommunication, serial transmission is more economic in terms of line plant.
Serial Port(s)/Transmission
Normally a DB 9 pin connector located on the mother board of a PC. A technique in which each bit of information is sent sequentially on a single channel.
Server(s)
Host Computer(s).
Service Entrance
See Campus Cable Entrance.
Serving Closet
See Satellite Telecommunications Closet/Room
Session Layer
Layer 5 of the OSI model. Responsible for establishment and control of dialogues between users on different machines. Synchronisation for reliable data transfer and token management to control use of the connection are services provided by this layer.
Sheath
A common term for the collection of twisted pairs of multipair cables.
Shield
The metallic layer that surrounds insulated conductors in shielded cable. The shield may be the metallic sheath of the cable or the metallic layer inside a nonmetallic sheath.
Shielded Twisted Pair Cable (STP)
An electrically conducting cable comprising one or more elements each of which is individually shielded. There may be an overall shield in which case the cable is referred to as a shielded twisted pair cable with an overall shield.
Signal To Noise Ratio (SNR)
The ratio of the signal magnitude to the noise magnitude and is usually expressed in dB. The higher the SNR of a system, the better is its performance.
Simplex
A transmission means allowing only one direction of transmission. (For example public broadcast radio).
Single-Fibre Cable
A plastic-coated fibre surrounded by an extruded layer of plastic encased in a synthetic strengthening material, and enclosed in a plastic sheath.
GLOSSARY
Satellite Telecommunications Closet/Room
313
GLOSSARY
GLOSSARY
Glossary (contd)
314
Glossary Contents Page
Singlemode
Optical fibre with a small core diameter in which only single mode is capable of propagation. 8.3 micron is the common standard core size.
Sleeves
Short lengths of rigid metal pipe, approximately 4 in. (10.1 cm) in diameter, located in riser telecommunications closets, that allows cables to pass from floor to floor when closets are vertically aligned. Sleeves also provide for easy pulling of cable.
Slots
Openings in the floor of riser telecommunications closets that allow cables to pass through from floor to floor when closets are vertically aligned. A slot accommodates more cables than an individual sleeve.
SNR
See Signal to Noise Ratio.
Sonet
Synchronous Optical Network; provides broadband connectivity for existing networks on a global scale.
Source Routing
A bridge uses source routing when the route to be followed is carried within each frame by the source stations. The source station acquires and maintains information by a search process, allowing parallel bridges to exist and to share traffic between the same two rings.
Splice
The physical joining of two or more copper wires or optical fibres to form a common connection.
Star
A physical point to point network topology.
Star Physical Topology
See Star.
Star Quad
A cable element which comprises of four insulated conductors twisted together. Two diametrically facing conductors from a transmission pair.
Star Topology
See Star.
ST Connector
See Straight-Tip (ST) Connector.
Storage Area Network (SAN)
A high speed network or subnetwork of shared storage devices.
STP
See Shielded Twisted Pair Cable.
Straight-Tip (ST) Connector
A fibre optic connector used to join single fibres together at interconnects or to connect them to fibre optic cross-connects.
Stranded Cable
A strong woven-copper-wire cable used to support cable in aerial distribution systems. The cable is lashed to the stranded cable during installation.
Structured Cabling
Flexible cabling scheme which allows rapid reconfiguration for office moves through patching.
Stud Cable
A short cable (usually 25 ft [7.6 m] or less) that extends from a cable terminal, protector, or block and is used to make connections to such devices.
Support Hardware
The racks, clamps, cabinets, brackets, trays, tools, and other equipment that provide the physical means to attach the transmission media and connecting hardware to walls or ceilings.
Surge
A sudden voltage rise and fall in an electrical circuit.
Switching
A function carried out by a switching hub, alleviating traffic by making virtual connections between transmitting and receiving nodes.
GLOSSARY
Glossary (contd)
Glossary Contents Page
Synchronisation
The method by which the bit patterns appearing on digital line systems may be properly ‘clocked’ and interpreted - allowing the beginning of particular patterns and frame formats to be correctly identified.
Synchronous
Signals that are sourced from the same timing reference and hence are identical in frequency.
Synchronous Data Transfer
Data transfer employing a strictly regular pattern, rather than using start and stop bits to distinguish character patterns from idle line operation.
System-Common Equipment
The equipment on a premises that provides functions common to terminal devices such as telephones, data terminals, integrated workstations terminals, and personal computers. Typically, the system-common equipment is the private branch exchange (PBX) switch, data packet switch, or central host computer. Often called common equipment.
SYSTIMAX® SCS
Brand name of Avaya’s Structured Cabling System.
TCP/IP
See Transport Control Protocol/Internet Protocol (TCP/IP).
Telecommunications
A branch of technology concerned with the transmission, emission and reception of signs, signals, writing, images and sounds; that is, information of any nature by cable, radio, optical or other electromagnetic systems.
Telecommunications Closet/Room An enclosed space for housing telecommunications equipment, cable terminations, and cross-connect cabling. The telecommunications closet is a recognised cross-connect point between the backbone and horizontal cabling subsystems. See also Satellite Telecommunications Closet/Room. A connector where the horizontal cable terminates. The telecommunications outlet provides the interface to the work area cabling.
Terminal Block
A protected or unprotected unit of wiring blocks, connecting blocks, and troughs that serves as a transition point between cable conductors.
Thermoplastic
A plastic material that softens and flows when heated and becomes firm when cooled. This process can be repeated.
Thermoset
A plastic material that is crosslinked by a heating process known as curing. Once cured, thermosets cannot be reshaped.
Thick Coax
The transmission medium used for Ethernet or IEEE 802.3 10Base5 LANs. It is a 50 ohm thick coax cable (commonly referred to as the thick yellow cable).
Thin Coax
The transmission medium used for IEEE 802.3 10Base2 LANs (sometimes referred to as CheaperNet). It is a 50 ohm thin coax cable.
TIA/EIA
North American Standards Organisation.
TIA/EIA 568A or B
North American Commercial Building Telecommunications Wiring Standard.
TIA/EIA 569
North American Commercial Building Standard for Telecommunications Pathways and Spaces. Its purpose is to standardise specific design and construction practices within and between buildings which are in support of telecommunications media and equipment.
GLOSSARY
Telecommunications Outlet
315
GLOSSARY
GLOSSARY
Glossary (contd)
316
Glossary Contents Page
TIA/EIA 606
North American Administration Standard for the Telecommunications Infrastructure of Commercial Buildings. Its purpose is to provide guidelines for a uniform administration scheme for the cabling infrastructure.
Token
A special data sequence that is continuously sent around the ring. The term “token” represents permission to transmit from one station to its downstream neighbour.
Token Ring
A data link protocol type which implements media access control (MAC) by the circulation of a token around a complete ring network. Each station in the ring sequentially receives the opportunity to send data on the network as the token is passed around the network.
Token Ring LAN
A 4 or 16 Mb/s LAN standard based on token passing access protocol originally developed by IBM. Sometimes referred to as IEEE 802.5 or ISO 8802-5 standard.
Topology
The physical or electrical configuration of a local communications network (that is, the shape or arrangement of the system). The most common distribution system topologies are the bus, ring, and star.
TP-PMD
Twisted Pair Physical Medium Dependent. A twisted pair version of the FDDI standard that allows 100 Mb/s transmission over Category 5 copper cable.
Transducer
A sensing device that converts a signal from one form to another e.g. mechanical to electrical.
Transition Point
A location in the horizontal cabling where a change of cable form takes place.
Transmission Distance
The actual length of the path from the transmitter of one node to the receiver of the next downstream node. The maximum transmission distance is determined by the maximum signal loss (attenuation limit) that can be withstood between any transmitter and receiver.
Transmission Media
The various types of copper wire and fibre optic cable used for transmitting voice, data, or video signals.
Transport Control Protocol/ Internet Protocol (TCP/IP)
A common network layer and transport layer data networking protocol.
Transport Layer
Layer 4 of the OSI model. The transport layer provides for end-toend data relaying service across any type of data network and is responsible for end-to-end reliability.
Trunk
A communication link between two switching systems. The term switching typically includes equipment in a central office (or the telephone company) and PBXs. A tie trunk connects PBXs. Central office trunks connect a PBX to the switching system at the central office. See also Private Branch Exchange (PBX).
Twinaxial Cable (TWINAX)
Two insulated conductors inside a common insulator, covered by a metallic shield and enclosed in a cable sheath.
Twisted Pair(s)
Two insulated copper wires twisted together. The twists, or lays, are varied in length to reduce the potential for signal interference between pairs. In cables greater than 25 pairs, the twisted pairs are
GLOSSARY
Glossary (contd)
Glossary Contents Page
grouped and bound together in a common sheath. Twisted pair is the most common type of transmission media. See Underwriters Laboratories (UL)
Underwriters Laboratories (UL)
A private testing laboratory concerned with electrical and fire hazards of equipment. With SYSTIMAX SCS components, several abbreviations are used to designate the approved use.
Unshielded Twisted Pair Cable
Normal copper building cable, capable of high-speed data transmission. Techniques exist to address the signal impairments due to the transmission characteristics of copper media and to limit the radiated emission of UTP media.
UTP
See Unshielded Twisted pair (UTP).
Video Conferencing
Real time communications via video between two or more users at separate locations.
Volt (V)
The standard unit of electromotive force or electrical pressure. One volt is the amount of pressure that will cause one ampere of current to flow through one ohm of resistance.
W
See Watt (W).
WAN
See Wide Area Network (WAN).
Watt (W)
A unit of power equal to one joule per second.
Wavelength
The physical distance of one electromagnetic wave cycle.
Wide Area Network (WAN)
Any physical network technology that spans large geographic distances. WANs usually operate at slower speeds and have higher delays than local area networks (LANs).
Windows
Graphics based operating system developed by Microsoft.
Wireless LANs
Local area network that communicates using radio technology.
Wiring Block
A moulded plastic block that is designed in various pair configurations to terminate cable pairs and establish pair location on 110 Connector Systems.
Wiring Closet
See Telecommunication Closet/Room.
Work Area
A building space where the occupants interact with telecommunications terminal equipment. A user’s work area which is typically 9 sq. metres or 100 sq ft.
Work Area Cable
A cable connecting the telecommunications outlet to the terminal equipment.
Work Area Subsystem
The part of a distribution system that includes the equipment and extension cords from the information outlet to the terminal device.
X.25
A communication architecture developed by the International Telegraph and Telephone Consultative Committee (CCITT).
Zone Method
A ceiling distribution method in which ceiling space is divided into sections or zones. Cable is then run to the centre of each zone to serve the information outlets nearby.
GLOSSARY
UL
317
WARRANTY
WARRANTY
Extended Product Warranty and Application Assurance Programme
318
SYSTIMAX® Structured Connectivity Solutions
Contents Page
WARRANTY
Extended Product Warranty and Application Assurance Programme
SYSTIMAX® Structured Connectivity Solutions
Contents Page
WARRANTY 319
ABBREVIATIONS
Abbreviations and Symbols
G
The following abbreviations and symbols may be used in this guide. This list does not include acronyms for individual vendors’ products A.
Ampère(s)
ARMS
Ampère(s) Root Mean Square
AC
Alternating Current
ADU
Asynchronous Data Unit
ANSI
American National Standards Institute
ILD
Intelligent Line Driver
ATM
Asynchronous Transfer Mode
in.
Inch(es)
AWG
American Wire Gauge
IO
Information Outlet
CATV
Community Antenna Television
I/O
Input/Output
CAU
Control Access Unit
IR
Current and Resistance
CB
Cable Budget
ISA
Industry Standard Architecture
CCITT
International Telephone And
ISDN
Integrated Services Digital Network
Telegraph Consultative Committee
ISM
Industry, Scientific, And Medical
C
Degrees Celsius
ISO
International Organisation For
CISPR
Comité International Special Des
ABBREVIATIONS
Perturbations Radioelectriques
320
IEC
International Electrotechnical Commission
IEEE
Institute Of Electrical And Electronic Engineers
Standardisation ITU-T
International Telecommunications Union-Telecommunications
Cond.
Conductor
CSA
Canadian Standards Association
ºK
Degrees Kelvin
DAS
Dual Attachment Station
kb/s
Kilobits Per Second
dB
Decibel(s)
kHz
Kilohertz
dB/ft
Decibels Per Foot
Komhs
Kiloohm(s)
dB/km
Decibels Per Kilometre
km
Kilometre(s)
dBmV
Decibel Millivolt(s)
LAN
Local Area Network
DC
Direct Current
LED
Light - Emitting Diode
DCP
Data Communications Processor
LGBC
Lightguide® Building Cable
DS1
Digital Signal Level 1
LGX
Lightguide Cross-Connect
DTMF
Dual Tone Multiple Frequency
LIU
Lightguide Interconnection Unit
EIA
Electronic Industries Association
æm
Micrometer(s) Or Micron(s)
EISA
Extended Industry Standard
m
Metre(s)
Architecture
Ma
Milliampere(s)
F
Degrees Fahrenheit
MADU
Multiple Asynchronous Data Unit
FCC
Federal Communications Commission
MAU
Multistation Access Unit
FDDI
Fibre Distributed Data Interface
Mbaud
Megabaud(s)
FOIRL
Fibre Optic Inter-Repeater Link
Mb/s
Megabits Per Second
Ft
Foot, Feet
MC
Micro Channel
GHz
Gigahertz
MHz
Megahertz
HVAC
Heating, Ventilation, and
MHz-km Megahertz-Kilometre(s)
Air-Conditioning
mi
Mile(s)
Hz
Hertz
MIC
Media Interface Connector
I
Current
mod.
Modular
Contents Page
ABBREVIATIONS
Abbreviations and Symbols (contd)
Contents Page
Manufacturing Resource Planning
SAS
msec
Millisecond(s)
SCS
Structured Cabling Systems
mV
Millivolt(s)
SDU
Synchronous Data Unit
NC
Normally Closed
sec
Second(s)
NEC
National Electrical Code
SECAM
Sequential Colour With Memory
NEXT
Near End Crosstalk
sq
Square
nm
Nanometre(s)
ST
Straight Tip
NO
Normally Open
STP
Shielded Twisted Pair
NTSC
National Television System Committee
TIA
Telecommunications Industry
MRP
Ohm(s)
Association
The standard unit of electrical resistance. One volt will cause one
Single Attachment Station
TP-PMD
Twisted-Pair Physical-Layer Medium-Dependent
ampere of current to flow through one ohm of resistance.
UL
Underwriters Laboratories
OIS
Office Information Systems
UTP
Unshielded Twisted Pair
OLIU
Optical Lightguide Interface Unit
V
Volt(s)
PAL
Phase - Alternation Line
VA
Volt Ampere(s)
PB
Power Budget
VAC
Volts AC
PBX
Private Branch Exchange
VAC RMS Volts AC Root Mean Square
PC
Personal Computer
VCR
Video Cassette Recorder
PMD
Physical Layer Medium - Dependent
VDC
Volts DC
PTZ
Pan/Tilt/Zoom
VHF
Very High Frequency
R
Resistance
VRMS
Volts Root Mean Square
RF
Radio Frequency
VS
Virtual Storage
RGB
Red-Green-Blue
W
Watt(s)
RI
Ring In
WAN
Wide Area Network
RMS
Root Mean Square
yd
Yard(s)
RO
Ring Out
ABBREVIATIONS 321
TRADEMARKS
Registered Trademarks
Contents Page
3 Com® and TokenLink®
ST®
are registered trademarks of 3Com Corporation
is a registered trademark of Lucent Technologies.
Application System/400®, AS/400® and IBM® are registered trademarks of
STII®
International Business Machines Corporation.
is a registered trademark of Lucent Technologies.
CSA® is a registered trademark of
SYSTIMAX®
Canadian Standards Association
is a registered trademark of Avaya Inc.
CSL Lightsplice®
Telex™
is a registered trademark of Avaya Inc.
is a registered trademark of the Telex Corporation
DEC® is a registered trademark of
UL® and UL
Digital Equipment Corporation.
are registered trademarks of Underwriters Laboratories Inc.
DEFINITY® is a registered trademark of Avaya Inc.
UNISYS® is a registered trademark of the}
DRS® and ISL®
UNISYS Corporation
Are registered trademarks of International Computers Ltd.
UNIX® is a registered trademark of
GigaSPEED®
UNIX System Laboratories, Inc.
is a registered trademark of Avaya Inc. VisiPatch™ iPatch
™
is a trademark of Avaya Inc.
is a trademark of Avaya Inc.
TRADEMARKS
Wang® LazrSPEED™
is a registered trademark of
is a trademark of Avaya Inc.
Wang Laboratories Inc.
Lightguide™
Note
is a registered trademark of
Other brand and product names are
Lucent Technologies.
the trademarks of their respective holders.
OptiSPEED™ is a trademark of Avaya Inc. PATCHMAX® is a registered trademark of Avaya Inc. QwikCrimp™ is a trademark of Avaya Inc.
322
ADDRESSES
Connectivity Solutions EMEA
Contents Page
Austria (Vienna)
Norway (Oslo)
The Netherlands (Bussum)
Tel. +43.133.153.2700
Tel. +47.22.99.62.31
Tel. +31.704.148960
Fax +43.133.153.2509
Fax +47.22.99.60.10
Fax +31.704.148961
Belgium (Waterloo)
Poland (Warazawa)
Turkey (Istanbul)
Tel. +32.2.357.5707
Tel. +48.22.577.3000 (3700)
Tel. +90.212.3270.749
Fax +32.2.357.5716
Fax +48.22.577.3810
Fax +90.212.259.87.31
Denmark (Ballerup)
Russia (Moscow)
United Arab Emirates
Tel. +45.70.27.99.01
Tel. +7095.363.6700
(Dubai)
Fax +45.70.27.99.02
Fax +7095.363.6714
Tel. +971.4.330.40.50
Finland (Espoo)
Saudi Arabia (Riyadh)
Tel. +358.9.2517.2455
Tel. +966.1.239.8931
United Kingdom (London)
Fax +358.9.455.5941
Fax +966.1.239.8898
Tel. +44.(0)20.7647.8126
France (Paris)
South Africa (Bryanston)
Tel. +33.1.41.28.53.54
Tel. +27.11.709.0078
Fax +33.1.41.28.53.60
Fax +27.11.709.0805
Germany (Frankfurt)
Spain (Madrid)
Tel. +49.69.96377.128
Tel. +34.91.387.63.48
Fax +49.69.96377.133
Fax +34.91.387.63.51
Ireland (Dublin)
Sweden (Stockholm)
Tel. +353.1.2042.067
Tel. +46.8.5220.7045
Fax +353.1.2040.235
Fax +46.8.5220.7145
Italy (Sestio San Giovanni - MI)
Switzerland (Wallisellen)
Tel. +39.02.26293.313
Tel. +41.1.832.1442
Fax +39.02.26293.301
Fax +41.1.832.1415
Fax +971.4.3303.668
Fax +44.(0)20.7647.8138
ADDRESSES 323
324
They’re not just customers. They’re relationships. Give them the care and feeding they need to grow. Would they prefer a phone call? A transaction on the web? Or someone taking them through the transaction? To have you call them back? Fax them? Or send what they need to their mobile? With Avaya you can do it all. And keep the conversation going. Visit avaya.com
What’s the best way for customers to reach you? Any way they want.
Communication without boundries
Visit our Web site at: www.avaya.com/connectivity or contact your local Avaya Account Manager or SYSTIMAX BusinessPartner for more information. Alternatively, please call +1 603 559 4429 or +1 800 344 0223 toll-free within the United States. SYSTIMAX, GigaSPEED, PATCHMAX and We Tote are registered trademarks of Avaya Inc. OptiSPEED, LazrSPEED, VisiPatch and QwikCrimp are trademarks of Avaya Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to Avaya products and services. © 2001 Avaya Inc. All rights reserved Printed in Ireland SYSA1358 avaya.com