Preview only show first 10 pages with watermark. For full document please download

Product Information Dcm Video Switch 4

   EMBED


Share

Transcript

Product Information DCM Video switch 4-gang TK VU 4 REG Safety instructions Assembly, installation, and commissioning must only be carried out by a qualified ! electrician For work on systems with 230 V AC mains current the safety requirements of DIN VDE 0100 must be observed. When installing DCM BUS systems the general safety rules for telecommunication systems in accordance with VDE 0800 must be observed: • • • • separate cabling for high and low voltage lines minimum distance of 10 cm for joint cabling arrangements, use of separators between high and low voltage lines in joint cable ducts, use of standard telecommunication cables, e. g. J-Y (St) Y with 0.8 mm² cross section Suitable lightning prediction must ensure that a voltage of 32 V DC will not be ! exceeded at the DCM BUS wires a and b. DCM = Door Communication Management 1 Device overview Terminals for camera input 1-3 Hold terminal Terminals for camera input 4 Output terminal Step terminal Run/Prog-indication Run/Prog-button Technical data Input voltage: Housing: Weight: Permissible ambient temperature: Input current: 2 + 24 V ± 8 % (Power supply &control unit) rail mounting device, 6 rail units 200 g 0 °C to 40 °C I(a) = 0.4 mA, I(P) = 21 mA Application The TK VU 4 REG is designed to switch between four video signals, which will be received of one (or more) video indoor stations. Up to 4 video switches can be installed in a DCM system. In this case the output terminals (3-7) will be wired parallel. Please install the all video switches side by side in the distribution board to achieve the best camera image quality. In an installation with multiple video switches, you have to finish all required program! ming steps before you trigger a bell button or start a communication. Otherwise multiple video signals will be switched on at the same time. Brief description Functions Automatic switching Video inputs Video outputs to the triggered outdoor station 4 1 3 Cable connection Wiring diagram Wiring example Video input 4 not connected Program input as "unused" ! Video outdoor station 1 Video outdoor station 2 Video outdoor station 1: AS-address = 01 program and lock Video outdoor station 2: AS-address = 02 program and lock 4 Audio outdoor station 3: AS-address = 03 program and lock Commissioning • Install all of the devices of the system completely. • Check the a, b and P wires for short-circuit. • Switch on the mains voltage. Please complete the full installation before you connect the system to the mains voltage! ! • Do NOT connect V1 and V2 with the P-, M-, a- or b-wire. Even a connection for a quick moment will destroy the device. • When connecting the video wires V1 (+) and V2 (-) observe polarity. If you can see a distorted image on the display, switch off the mains voltage and change the wires V1 and V2.. Settings Factory setting The inputs S1, S2, S3, S4 are pre-programmed with the AS-addresses 1, 2, 3 and 4. Device settings You can program the video switch with the service device TK-SERVICE or the commissioning software TK-IBS-TOOL. Each outdoor station has to be assigned with an AS-address. The AS-address has to be locked. Thus every door call transmitted the respective AS address of the outdoor station. The video switch allocates the video inputs to the respective AS addresses. A video input will be automatically activated with a triggered door call. The AS-address of the video input has to comply with the AS-address of the outdoor station. Caution! Video outdoor stations or cameras without outdoor stations have to be linked ! with available AS addresses from 0 to 30. Please only use the function: "Connect camera input with video outdoor station". The combination with audio outdoor station is possible. Caution! ! Link outdoor stations without camera with AS-addresses greater 31 and lock the programmed AS-addresses. 5 Example Connection of 2 video outdoor stations to the camera inputs S1 and S2. • Assign the AS-addresses of the outdoor stations to AS=1 and AS=2 and lock the AS-addresses ( with service device or commissioning software, see manual of outdoor station ) • Connect the outdoor station (AS=1) to the input S1. • Connect the outdoor station (AS=2) to the input S2. • Assign the unused inputs with " Input unused" Programming Programming with the service device TK SERVICE • Assign and lock all AS addresses of the out door stations • Assign the bell buttons of the out door stations with the serial no. of the respective indoor station • Assign the camera inputs S1, S2, S3 and S4 of the TK VU4 REG to the respective AS-addresses with the function "Connect camera input with video outdoor station", if factory settings have to changed. • Assign unused camera input NOTE: First assign and lock the AS-addresses of the video outdoor station. Connect camera input with video outdoor station Assign unused camera input NOTE: Camera input 1 cannot be assigned as "unused". TK VU 4 REG - Load factory settings Ser.-Nr.M = K = AS = Seriial number ofr TK VU4 REG Number of the camera input of TK VU4 REG (= 1 ... 4) AS-address of outdoor stations for this camera input (= 0 ... 63) Programming with the commissioning software TK-IBS-TOOL • Assign and lock all AS addresses of the out door stations • Assign the bell buttons of the out door stations with the serial no. of the respective indoor station • Assign the camera inputs S1, S2, S3 and S4 of the TK VU4 REG to the respective AS-addresses. • Select for unused camera inputs: Input unused 6 Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: ALBRECHT JUNG GMBH & CO. KG Service-Centre Kupferstr. 17-19 44532 Lünen Germany Technique (DCM) Service-Line: 0 23 55 . 80 65 52 Fax: 0 23 55 . 80 62 55 E-Mail: [email protected] Service-Line: 0 23 55 . 80 65 51 Telefax: 0 23 55 . 80 61 89 E-Mail: [email protected]     Albrecht Jung GmbH & Co. KG P.O. Box 1320 58569 Schalksmühle Germany http://gb.jung.de/ www.jung-catalogue.com The -sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. Technical subjects to change. EN_TK_VU4_REG.doc 05/201010 7