Preview only show first 10 pages with watermark. For full document please download

Product Overview

   EMBED


Share

Transcript

Job Name: Date: Catalog #: Notes: EDIN ANALOG TO DMX INTERFACE #1006 PRODUCT OVERVIEW SPECIFICATIONS The eDIN #1006 converts 24 analog 0-10VDC sources or 24 dry contact closures into a DMX512 signal. A built-in DMX merger combines signal output with other in-line #1006 interfaces, lighting consoles or controllers. Also may be used as a simple snapshot playback device, holding up to 24 ‘looks’.  1500V opto-isolation between input and output ports  250V fault protection on input and output ports  Input operating voltage: 9-30 VDC  6W power consumption  Operating conditions: -10°-50°C; 10-90% relative humidity, non- condensing FEATURES STANDARDS COMPLIANCE  DMX512 start address and operating mode may be set from front  ANSI E1.11 DMX512-A(2008)/USITT DMX512(1990) panel interface or remotely using E1.20 RDM  Indicator LEDs for power, processor, DMX input status and contact closure operation  Convert 0-10VDC input to DMX512 output levels  Alternate contact closure mode, for off/full DMX control  Recall mode allows capture and playback of up to 24 discrete, full universe ‘looks’  LED indicator for CCI mode  Built-in merger allows in-line operation with other DMX sources in either recall or input modes  One DMX512-A/RDM data input connection  One passive DMX512-A data through connection  Data and power easily daisy-chained between modules  Termination switch  Independent test function, in both analog and contact closure modes  Firmware field-upgradable using RDM (requires Pathway Pathport node and RDM utility program)  ANSI E1.20 RDM(2010) - Remote Device Management  ANSI E1.3 0-10V Analog Control  CE/FCC  RoHS 2002/95/EC  Class 2 Low Voltage WEIGHTS AND DIMENSIONS  0.70 lbs (0.316 kg)  3.6”W x 6.25”L x 1.5”H (91mm x 160mm x 38mm) INCLUDED FURNISHINGS  DIN tray (housing) with end caps  12” (300mm) x 35mm DIN rail  Installation/Operations manual    #103 - 1439 17th Ave SE Calgary AB Canada T2G 1J9 Phone + 1 403 243 8110 [email protected] www.pathwayconnect.com © 2013 Acuity Brands Lighting Canada Inc. All Rights Reserved Form #0610-0100-1006 1 of 3 8.7.13 eDIN #1006 Analog to DMX Interface OPERATING MODES       Mode 1 : Highest Takes Precedence (HTP) - The highest level present on the analog input OR the DMX512 input for a given control channel is the level that will be present on the DMX512 output. Mode 2 : Analog Takes Precedence (Analog Priority) - If the analog input level for a given channel is 4% or greater (8-bit value greater than 10), the DMX512 output for that channel will reflect the analog input value, and the corresponding DMX 512 input value will be ignored. If the analog input value for a given channel is less than 4% (8-bit value less than 11), the DMX input level will determine the output level for that channel. Mode 3 : DMX Takes Precedence (DMX Priority) - Whenever DMX512 input data stream is present at the DMX IN, the DMX input levels will determine the DMX512 output levels of all channels, and all analog input levels will be ignored. Mode 4 : Contact Closure Input - Whenever a given contact input is closed for a given channel (input shorted to COM), the DMX512 output for that channel will be 100% (8-bit value=255) . When the contact input is open, the output for that channel will be determined by the DMX input level, if present. Mode 5 : Preset Recall - When a given contact input is closed momentarily (input shorted to COM), the corresponding recorded preset will be activated on a crossfade time of 5 seconds. All 512 possible DMX channels are stored for each preset. A recalled preset will be HTP (highest-takes-precedence) merged, on a channel-by-channel basis, with any DMX input present on the DMX IN port. Mode 6 : DMX Takes Precedence over Preset Recall - Whenever DMX512 is present at the DMX IN, the DMX input levels will determine the DMX512 output levels, and all recalled presets will be ignored. ANALOG INPUT RISER POWER SUPPLY POWER SUPPLY ANALOG 0-10VDC INPUTS D2D2+ ISO 5V PWR D2+ DMX LIGHTING CONTROLLER (OPTIONAL) DMX OUT D2- DMX IN D1+ GRD 18 17 13 UTIL 14 TEST ADDRESS 15 MODE 16 8 CCI MODE 9 ANALOG SLIDERS DMX INPUT 10 DC POWER IN 11 PROCESSOR 12 7 6 5 SHLD COM 4 D1- 3 D1+ 2 D2- 0/+10VDC ANALOG/CONTACT CLOSURE INPUTS eDIN 24 CHANNEL ANALOG DMX REV .2 POWER IN 9-30 VDC 5 Watts MAX D2+ SHLD COM D2- D1- D1+ D1+ D1- D2- COM SHLD D2+ DMX OUTPUT MERGED/PRIORITIZED ACCORDING TO OPERATING MODE 21 ANALOG SLIDERS 20 19 18 17 16 15 14 13 12 11 ANALOG SLIDERS 10 9 8 7 6 5 4 3 DMX512 DEVICES, INTERFACES DIMMERS, LIGHTING FIXTURES 2 D2+ 1 DMX TERMINATE ON OFF SHLD COM D1- ANALOG SLIDERS 1 DMX TERMINATE ON OFF ISO 5V PWR D2+ DMX OUT D1+ 19 22 V+ DMX THRU D1- DMX THRU SHLD COM 0/+10VDC ANALOG/CONTACT CLOSURE INPUTS eDIN 24 CHANNEL ANALOG DMX REV .2 UTIL TEST CCI MODE MODE DMX INPUT PROCESSOR ADDRESS POWER IN 9-30 VDC 5 Watts MAX 23 V- 21 20 24 DMX IN GRD 22 V+ COM V- 23 V- DC POWER IN V+ 24 V- ENTER COM ENTER V+ ANALOG 0-10VDC INPUTS D2D1+ D1COM SHLD DMX OUTPUT MERGED/PRIORITIZED ACCORDING TO OPERATING MODE MULTIPLE INPUT CARDS MAY BE CONNECTED TOGETHER   #103 - 1439 17th Ave SE Calgary AB Canada T2G 1J9 Phone + 1 403 243 8110 [email protected] www.pathwayconnect.com © 2013 Acuity Brands Lighting Canada Inc. All Rights Reserved Form #0610-0100-1006 2 of 3 eDIN #1006 Analog to DMX Interface CONTACT CLOSURE/ PRESET RECALL RISER DRY CONTACT CLOSURE FOR NON-DIM OR PRESET RECALL COM ENTER V+ 24 VGRD POWER SUPPLY 23 22 eDIN 24 CHANNEL ANALOG DMX REV .2 V+ UTIL TEST CCI MODE MODE DMX INPUT PROCESSOR DC POWER IN ADDRESS POWER IN 9-30 VDC 5 Watts MAX D1D1+ D2- DMX THRU SHLD COM 0/+10VDC ANALOG/CONTACT CLOSURE INPUTS V- D2- 18 17 16 15 14 eDIN #1003 CONTACT CLOSURE INTERFACE 13 12 11 10 9 8 7 6 OCCUPANCY SENSOR 5 2 1 ISO 5V PWR D2D1+ D1COM SHLD D2+ DMX512/RDM PIN OUT: D2+ DMX OUT D1+ BUTTON/SWITCH PANEL 19 3 DMX TERMINATE ON OFF DMX IN D1- 20 4 D2+ SHLD COM DMX LIGHTING CONTROLLER (OPTIONAL) 21 XLR PIN # 1 2 3 4 5 DMX OUTPUT MERGED/PRIORITIZED WITH OPTIONAL INPUT DMX512 DEVICES, INTERFACES DIMMERS, LIGHTING FIXTURES PURPOSE Shield Data - (complement) Data + (true) Data - (pair 2 complement) Data + (pair 2 true) ORDERING INFORMATION PART # DESCRIPTION 1006 eDIN Analog to DMX Interface, 24 Channel ACCESSORIES 1001-30 24VDC - 30W DIN-mountable Power Supply 1103 Rack-mount Panel Kit (2RU) wih two 16.5” (420mm) sections of DIN rail 1105 Small eDIN Enclosure (NEMA1) with 9.5” (240mm) of vertical DIN rail 1106 Large eDIN Enclosure (NEMA1) with 19.5” (495mm) of vertical DIN rail 1107 Large eDIN Enclosure (NEMA1) with three rows of 9.5” (240mm) horizontal DIN rail 4000 eDIN Enclosure Assembly Service   #103 - 1439 17th Ave SE Calgary AB Canada T2G 1J9 Phone + 1 403 243 8110 [email protected] www.pathwayconnect.com © 2013 Acuity Brands Lighting Canada Inc. All Rights Reserved Form #0610-0100-1006 3 of 3