PRODUCT PROFILE 1747 DPS2 Configurable Port Splitter 1747 RS-232/DF1 Port Splitter The new 1747 DPS2 Configurable Port Splitter and 1747 RS-232 DPS1 Port Splitter from Rockwell Automation expand connectivity and communications options for Allen-Bradley controller platforms.
Place image here
ADVANTAGES 1747-DPS1/DPS2 port splitters allow single RS-232/DF1 ports on Rockwell Automation controllers (e.g. SLC™ 500, MicroLogix™, PLC-5®, ControlLogix®, CompactLogix™) to be expanded (or split) for communication with two externaldevices at the same time. The 1747-DPS1, when connected to a controller, provides one full-function port for two-way communication between the controller and a local network. The second port is respond-only and can run a programming terminal or human machine interface (HMI). Both the network port and respond-only port are DF1 full-duplex 19.2 kbaud. The 1747-DPS2 provides similar functionality but also allows the network port to be configured for communication with DH-485, DF1 half duplex (master or slave), DF1 full duplex, or DF1 radio modem networks. The network port is configurable with a software utility provided via web access. Both products require an external 24V DC power source connected to power source terminals. All communications ports use standard Allen-Bradley programming cables. The DPS2 port splitter has fully-isolated communication ports. Therefore, no external isolation is required.
SPECIFICATION
1747-DPS1
Dimensions H X W X D
3.18 in. x 1.83 in. x 0.97 in 80.8 mm x 46.5 mm x 24.5 mm
Dimensions with DIN Rail Mounting Hardware
4.29 in. x 1.99 in. x 1.22 in. 109 mm x 50.6 mm x 31 mm
1747-DPS2 3.98 in x 1.38 in x 2.75 in 101mm x 35mm x 70mm
Same as above
Controller Port
8-pin DIN,Autobaud at 19.2 Kbps or 38.4 Kbps /Auto-checksum BCC or CRC
9-pin male D-shell,Autobaud at 19.2 Kbps or 38.4 Kbps /Auto-checksum BCC or CRC
Network Port
8-pin DIN, 19.2 Kbps / CRC
9-pin male D-shell, 6-pin phoenix style connector for DH-485, Configurable for DH-485, DF1 half duplex (master or slave), DF1 full duplex, or DF1 radio modem networks.
Prog/HMI Port
9-pin male D-shell, 19.2 Kbps / CRC
9-pin male D-shell, 19.2 Kbps / CRC
Standards and Regulatory Approvals
UL, C-UL, C-Tick and CE compliant for all applicable directives when product or packaging is marked
UL, C-UL, Class I, Div. 2, C-Tick and CE compliant for all applicable directives when product or packaging is marked
Temperature Range
0° to 60° C (32° to 140° F)
0° to 60° C (32° to 140° F)
Power Supply Requirements
100 mA at 24V dc Class 2/SEL V
100 mA at 24V dc
Isolation
NO
YES
NETWORK DIAGRAM - 1747 DPS1/DPS2
DANGER
DANGER
Publication 1747-PP019B-EN-P – December 2007