Preview only show first 10 pages with watermark. For full document please download

Product Safety Data Sheet Xerox

   EMBED


Share

Transcript

Product Safety Data Sheet Product: XEROX DocuColor 30 CP / DocuColor 30 Pro DocuColor 40 / DocuColor 40 CP Optional Accessories - Sorter, ADF Section I - Product Identification Manufacturer's Name Xerox Corporation PSDS No.: ISSUE DATE: REV. DATE: 0757 6/17/96 1/10/01 Emergency No. (585) 422-2177 EH&S Inquiries (800) 828-6571 Manufacturer's Address Rochester, New York 14644 Product Designation DocuColor 30 CP / DocuColor 30 Pro DocuColor 40 / DocuColor 40 CP Section II - Electrical Information Line Voltage (Volts) 208/220/230/240 Line Current (Amps) 17 Product Identifier: XHA-1 Freq. (Hertz) 50/60 Line Cord/Plug Specification Three Wire & Ground NEMA Type 14-30R Plug Branch Cir. Protection (Amps) 30 Power Consumption (Watts)* Running: 1,775 Standby: 700 Agency Approvals UL File Number E 51242 cUL File Number E 51242 Section III - Supplies Toner,black Toner,cyan Toner, magenta Toner, yellow Developer, black Developer, yellow Developer, cyan Developer, magenta Fuser Agent II Xerox Part No. 6R718,XCL:6R800,XLA:6R722 RX:6R90247 6R719,XCL:6R801,XLA:6R723 RX:6R90250 6R721,XCL:6R803,XLA:6R725 RX:6R90249 6R720,XCL:6R802,XLA:6R724 RX:6R90248 5R319,XCL:5R563,XLA:5R323 RX:5R90210 5R321,XCL:5R565,XLA:5R325 RX:5R90211 5R320,XCL:5R564,XLA:5R324 RX:5R90213 5R322,XCL:5R566,XLA:5R326 RX:5R90212 8R3993,RX:8R4004 Material Safety Data Sheet Article ** (A4) Article ** (A3) Article ** (A2) Article ** (A1) B-0293 B-0290 B-0292 B-0291 D-0490 * Based on a five minute average ** MSDS is not required by OSHA, Hazard Communication Std., 29 CFR or WHMIS HPA (Section II (2)) www.xerox.com Reference “About Xerox” Product: DocuColor 30 CP / DocuColor 30 Pro DocuColor 40 / DocuColor 40 CP PSDS No.: 0757 Section IV - Environmental Information (Configuration: w/o Sorter and ADF) Product Size Heat Emission* Environmental Limitations (Centimeters / Inches) (BTU/HR) Min D: 128 / 50.4 Running: 6,059 Relative Humidity (%): 15 o W: 95 / 37.4 Standby: 2,389 Ambient Temp. ( C): 10 H: 127 / 50.0 Floor Space Requirements (Meters / Feet) Movable 2.4 x 3.1 / 7.9 x 10.2 Unmovable 3.2 x 3.1 / 10.5 x 10.2 Mobility Plate 2.5 x 3.1 / 8.2 x 10.2 Sorter/Movable 2.4 x 3.8 / 7.9 x 12.5 Sorter/ Mobility Plate 2.5 x 3.8 / 8.2 x 12.5 Section V - Emission/Exposure Information** Light Sources FDA Approved Class 1 Laser System There is no operator or service access to the beam. Document: Frosted Tungsten Halogen @ 29000K Electromagnetic Emissions US FCC: Class A Canada DOC: Class A Audible Noise Run 53.8 dB(A) Standby 48.0 dB(A) Impulse 57.8 dB(A) Ozone Concentration Based on Simulation Model: Daily Copy Volume 5,250 copies/8 hours Room Size 9.1 m3 1/2 Air Room Change per Hour Ozone Filter available Weight (K Grams / Lbs.) 650 / 1,433 FDA Accession # 9320708-02 TLV 85.0 dB(A) 32.2 ug/min 0.006 ppm (TWA) 0.008 ppm (PEAK) TLV 0.10 ppm Total Dust 0.007 mg/m3 Organics < 10 ppb TLV 10 mg/m3 Accessories: Max 85 32 Sorter: Product Size (cm) - D: 117, W: 73, H: 66, Weight (kg): 68 ADF: Product Size (cm)- D: 53, W: 61, H: 23, Weight (kg): 16 * Based on a five minute average ** TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for a normal eight -hour workday. All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions. www.xerox.com Reference “About Xerox”