Transcript
Product Specifications E15Z01P42
Tri Band Tower Mounted Amplifier, 1800/2100/2600 MHz, 12 dB, 2 BTS & 2 ANT ports, AISG with 1 RET connector (3 devices with 2 sub-units each) l
Industry leading PIM performance
l
TMA is operating in AISG & CWA mode, Alarm Current consumption CWA mode 190 mA
l
2 input ports and 2 output ports
l
Designed to boost UP-Link Coverage and KPIs
General Specifications Product Type
1-BTS:1-ANT (Uniplex)
Modularity
2-Twin
Includes
Mounting hardware
Electrical Specifications Sub-module
1|2
1|2
1|2
Branch
1
2
3
Port Designation
ANT
ANT
ANT
License Band
DCS 1800, LNA
IMT 2100, LNA
IMT 2600, LNA
Electrical Specifications Rx (Uplink) Frequency Range
1710–1785 MHz
1920–1980 MHz
2500–2570 MHz
Bandwidth
75.00 MHz
60.00 MHz
70.00 MHz
Gain, nominal
12.0 dB
12.0 dB
12.0 dB
Noise Figure, typical
1.7 dB
1.3 dB
1.5 dB
Total Group Delay, typical
120 ns
60 ns
60 ns
Return Loss, typical
20 dB
20 dB
20 dB
Insertion Loss - Bypass Mode, typical
1.7 dB
1.7 dB
2.2 dB
Return Loss - Bypass Mode, typical
18 dB
18 dB
18 dB
Electrical Specifications Tx (Downlink) Frequency Range
1805–1880 MHz
2110–2170 MHz
2620–2690 MHz
Bandwidth
75.00 MHz
60.00 MHz
70.00 MHz
Insertion Loss, typical
0.45 dB
0.35 dB
0.40 dB
Total Group Delay, typical
50 ns
25 ns
30 ns
Return Loss, typical
21 dB
21 dB
21 dB
Input Power, RMS, maximum
100 W
100 W
100 W
Input Power, PEP, maximum
1000 W
1000 W
1000 W
3rd Order PIM, typical
-161 dBc
-165 dBc
-161 dBc
3rd Order PIM Test Method
Two +43 dBm carriers
Two +43 dBm carriers
Two +43 dBm carriers
Product Classification Product Type
Tower mounted amplifier
©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 27, 2017
page 1 of 4 September 11, 2017
Product Specifications E15Z01P42
AISG Electrical Specifications Voltage, AISG Mode
10–30 Vdc
Protocol
AISG 2.0
AISG Connector
8-pin DIN Female
AISG Connector Standard
IEC 60130-9
dc Power/Alarm Electrical Specifications Voltage
7–30 Vdc
dc Switching/Redundancy
Yes
Alarm Current, CWA Mode
190 mA ±10 mA
Lightning Surge Current
10 kA
Lightning Surge Current Waveform 8/20 waveform
©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 27, 2017
page 2 of 4 September 11, 2017
Product Specifications E15Z01P42
Block Diagram
Mechanical Specifications RF Connector Interface
7-16 DIN Female
Color
Gray
Mount Type
Pole
Mounting Pipe Diameter
42.6–122 mm
Mounting Pipe Hardware
Band clamps (2)
|
Wall
Dimensions Height
326.0 mm
Width
245.0 mm | 9.6 in
|
Depth
125.0 mm | 4.9 in
Volume
10.0 L
Weight
14.2 kg
|
12.8 in
31.3 lb
Environmental Specifications Operating Temperature
-40 °C to +65 °C (-40 °F to +149 °F)
Relative Humidity
Up to 100%
Ingress Protection Test Method
IEC 60529:2001, IP67
©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 27, 2017
page 3 of 4 September 11, 2017
Product Specifications E15Z01P42
Outline Drawing
Regulatory Compliance/Certifications Agency ISO 9001:2008
Classification Designed, manufactured and/or distributed under this quality management system
©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 27, 2017
page 4 of 4 September 11, 2017