Preview only show first 10 pages with watermark. For full document please download

Product Specifications

   EMBED


Share

Transcript

Product Specifications E15S09P49 Tower Mounted Amplifier, Twin Diplexed PCS/AWS TMA with 700–850 bypass     Electrical Specifications Rx (Uplink) Bandwidth  60.00 MHz  License Band  PCS  Frequency Band  1850 – 1910 MHz  Gain  12 dB  Gain Tolerance  ±1  Noise Figure, Full Band, typical  1.90 dB @ 12 W/W  Input P1dB, typical  20 dBm  Return Loss, minimum  20 dB  Insertion Loss, Bypass Mode, typical  2.85 dB  Return Loss, Bypass Mode, typical  16 dB  Total Group Delay, maximum  150 ns    Electrical Specifications Tx (Downlink) Bandwidth  60.00 MHz  Insertion Loss, maximum  0.70 dB  License Band  PCS  Frequency Band  1930 – 1990 MHz  3rd Order IMD  ­110 dBm  3rd Order IMD Test Method  Two +43 dBm carriers  Input Power, RMS, maximum  200 W  Input Power, PEP, maximum  3000 W  Total Group Delay, maximum  55 ns    Electrical Specifications 2 Rx (Uplink) License Band  AWS  Frequency Band  1710 – 1755 MHz  Bandwidth  45.00 MHz  Gain  12 dB  Gain Tolerance  ±1  Noise Figure, Full Band, typical  1.45 dB @ 12 dB  Input P1dB, typical  20 dBm  Return Loss, minimum  20 dB  Insertion Loss, Bypass Mode, typical  2.10 dB  Return Loss, Bypass Mode, typical  16 dB  Total Group Delay, maximum  50 ns  ©2013 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 26, 2013 page 1 of 4 August 30, 2013 Product Specifications E15S09P49   Electrical Specifications 2 Tx (Downlink) Bandwidth  45.00 MHz  Insertion Loss, maximum  0.30 dB  License Band  AWS  Frequency Band  2110 – 2155 MHz  Input Power, RMS, maximum  200 W  Input Power, PEP, maximum  3000 W  Total Group Delay, maximum  15 ns    Electrical Specifications Voltage  7–18 Vdc  Alarm Functionality  Failure current  Failure Current Consumption  180–200 mA @ 10–18 V  Lightning Surge Capability Waveform  8/20 waveform  Lightning Surge Current  5 kA  ©2013 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 26, 2013 page 2 of 4 August 30, 2013 Product Specifications E15S09P49 Block Diagram           Mechanical Specifications Connector Interface  7­16 DIN Female  Connector Interface Style  Long neck  Wind Speed, maximum  67 m/s  Color  Gray    Environmental Specifications Operating Temperature  ­40 °C to +65 °C (­40 °F to +149 °F)  Ingress Protection Test Method  IEC 60529:2001, IP67    Dimensions Height  255.0 mm Width  236.0 mm | 9.3 in  Depth  123.0 mm | 4.8 in  Weight  10.2 kg | | 10.0 in  22.5 lb  ©2013 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 26, 2013 page 3 of 4 August 30, 2013 Product Specifications E15S09P49 Outline Drawing         ©2013 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 26, 2013 page 4 of 4 August 30, 2013