Preview only show first 10 pages with watermark. For full document please download

Product Specifications

   EMBED


Share

Transcript

Product Specifications CX3450004    |    150T135P3500JCASS COEX ConQuest® Cable in Conduit, 1 1/2 in, SDR 13.5, terracotta (P3® 500 JCASS) Product Classification Brand ConQuest® Product Type Coaxial cable-in-conduit Dimensions Nominal Size 1-1/2 in Wall Thickness Designation SDR 13.5 Length 731.52 m Weight 441.0 lb/kft | 2400.00 ft General Specifications Cable-In-Conduit Type P3® in duct Cable Type 500 series Conduit Type Non-toneable Color Terracotta Brand ConQuest® Wall Type Smooth Included Products 5302203 | CX3499999 P3® 500 JCASS | — 75 Ohm P3® Trunk and Distribution Cable, black PE jacket, flooded for underground 150T135 EMPTY DUCT COEX — ConQuest® Empty Conduit, 1 1/2 in, SDR 13.5, terracotta ©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: June 26, 2017 page 1 of 5 September 28, 2017 Product Specifications 5302203    |    P3 P3® ® 500 JCASS 75 Ohm P3® Trunk and Distribution Cable, black PE jacket, flooded for underground Product Classification Brand P3® Product Type Coaxial hardline cable Construction Materials Corrosion Protection Migraheal® Jacket Material PE Center Conductor Material Copper-clad aluminum Construction Type Swaged Dielectric Material Foam PE Outer Conductor Material Aluminum Dimensions Diameter Over Center Conductor, nominal 2.769 mm | 0.109 in Diameter Over Dielectric, nominal 11.481 mm | 0.452 in Diameter Over Outer Conductor, nominal 12.700 mm | 0.500 in Diameter Over Jacket, nominal 14.478 mm | 0.570 in Jacket Thickness, nominal 0.7620 mm | 0.0300 in Outer Conductor Thickness, nominal 0.6096 mm | 0.0240 in Cable Length 732 m Shipping Weight 123.00 lb/kft | 2400 ft Electrical Specifications dc Resistance, Inner Conductor, nominal 1.35 ohms/kft dc Resistance, Outer Conductor, nominal 0.37 ohms/kft dc Resistance, Loop, nominal 1.72 ohms/kft dc Resistance Note Nominal values based on a standard condition of 20 °C (68 °F) Capacitance 50.2 pF/m Capacitance Tolerance ±1.0 pF/ft Characteristic Impedance 75 ohm Characteristic Impedance Tolerance ±2 ohm Jacket Spark Test Voltage 5000 Vac Nominal Velocity of Propagation (NVP) 87 % Operating Frequency Band 1002–1218 MHz Structural Return Loss 30 dB @ 5–1002 MHz | 15.3 pF/ft | 5–1002 MHz Environmental Specifications Environmental Space Buried General Specifications ©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 7, 2017 page 2 of 5 September 28, 2017 Product Specifications 5302203   |   P3 5302203   |   P3® ® 500 JCASS Cable Type 500 series Brand P3® Jacket Color Black Packaging Type Reel Short Description P3 500 JCASS SM PR997 Warranty One year Mechanical Specifications Minimum Bend Radius, bonded 88.90 mm | Pulling Tension, maximum 136 kg 300 lb | 3.50 in Electrical Performance Frequency 5 MHz 55 MHz 83 MHz 85 MHz 204 MHz 211 MHz 250 MHz 300 MHz 350 MHz 400 MHz 450 MHz 500 MHz 550 MHz 600 MHz 750 MHz 865 MHz 1000 MHz 1002 MHz 1300 MHz 1400 MHz 1500 MHz 1600 MHz 1700 MHz 1794 MHz 1800 MHz Attenuation (dB/100 m) 0.52 1.77 2.17 2.23 3.51 3.58 3.94 4.30 4.69 5.02 5.35 5.67 5.97 6.27 7.09 7.68 8.27 8.33 2.95 3.09 10.55 10.97 11.38 11.76 11.78 Attenuation (dB/100 ft) 0.16 0.54 0.66 0.68 1.07 1.09 1.20 1.31 1.43 1.53 1.63 1.73 1.82 1.91 2.16 2.34 2.52 2.54 2.81 2.94 3.22 3.34 3.47 3.58 3.59 * Attenuation listed represents maximum values at standard condition of 20 °C (68 °F) Regulatory Compliance/Certifications Agency RoHS 2011/65/EU ISO 9001:2008 Classification Compliant Designed, manufactured and/or distributed under this quality management system ©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: July 7, 2017 page 3 of 5 September 28, 2017 Product Specifications CX3499999    |    150T135 EMPTY DUCT COEX ConQuest® Empty Conduit, 1 1/2 in, SDR 13.5, terracotta Product Classification Brand ConQuest® Product Type Empty conduit Dimensions Nominal Size 1-1/2 in Wall Thickness Designation SDR 13.5 Inner Diameter, nominal 40.589 mm Length 914.40 m Outer Diameter, nominal 48.260 mm Wall Thickness, minimum 3.581 mm Weight 344.0 lb/kft | | 1.598 in 3000.00 ft | | 1.900 in 0.141 in General Specifications Color Terracotta Conduit Type Non-toneable Wall Type Smooth Brand ConQuest® Warranty One year Material Specifications Density Test Method ASTM D792A Density, maximum 0.955 g/cm³ Density, minimum 0.941 g/cm³ Design Standard ASTM D3350-05 Environmental Stress Crack Resistance Failure rate of 10% within 96 hours Environmental Stress Test Method ASTM D1693, ESCR Condition B Flexural Modulus, minimum 552 N/mm² | Flexural Property Test Method ASTM D790 Hydrostatic Design Basis Not pressure rated Hydrostatic Design Test Method ASTM D2837 Material Type High density polyethylene (HDPE) Melt Flow Rate Test Method ASTM D1238 Melt Flow Rate, maximum 0.39 g/10 min 80000 psi ©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: June 26, 2017 page 4 of 5 September 28, 2017 Product Specifications CX3499999   |   150T135 EMPTY DUCT COEX Tensile Property Test Method ASTM D638 Tensile Strength at yield, minimum 21 N/mm² | 3000 psi Mechanical Specifications Minimum Bend Radius, unsupported 508.0 mm Pulling Tension, maximum 660.0 kg | | 20.0 in 1455.0 lb Regulatory Compliance/Certifications Agency ISO 9001:2008 Classification Designed, manufactured and/or distributed under this quality management system * Footnotes Environmental Stress Crack Resistance ESCR—Environmental Stress Crack Resistence ©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: June 26, 2017 page 5 of 5 September 28, 2017