Transcript
Product Specifications E15R05P19
Tower Mounted Amplifier, Twin Upper C 700 MHz with AISG and Variable Gain
General Specifications Product Type
1-BTS:1-ANT (Uniplex)
Modularity
2-Twin
Includes
Mounting hardware
Electrical Specifications Sub-module
1
2
Branch
1
1
Port Designation
ANT 0
ANT 1
AISG 2.0 Device Subunit
1.a
1.b
License Band
USA 750, LNA
USA 750, LNA
Frequency Range
777.5–787 MHz
777.5–787 MHz
Bandwidth
9.50 MHz
9.50 MHz
Gain, nominal
13.0 dB
13.0 dB
Gain Tolerance
±1.0 dB
±1.0 dB
Gain Adjustment Range
4–13 dB
4–13 dB
Gain Adjustment Range Increments
1.0 dB
1.0 dB
Noise Figure, typical
1.2 dB
1.2 dB
Noise Figure at 8 dB, typical
1.5 dB
1.5 dB
Noise Figure at 4 dB, typical
2.2 dB
2.2 dB
Total Group Delay, maximum
330 ns
330 ns
Return Loss, typical
24 dB
24 dB
Return Loss at 8 dB, typical
22 dB
22 dB
Return Loss at 4 dB, typical
20 dB
20 dB
Insertion Loss - Bypass Mode, typical
2.3 dB
2.3 dB
Return Loss - Bypass Mode, typical
16 dB
16 dB
TX Band Rejection, minimum
80 dB
80 dB
Frequency Range
746–756 MHz
746–756 MHz
Bandwidth
10.00 MHz
10.00 MHz
Insertion Loss, maximum
0.40 dB
0.40 dB
Insertion Loss, typical
0.35 dB
0.35 dB
Electrical Specifications Rx (Uplink)
Electrical Specifications Tx (Downlink)
©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: May 19, 2017
page 1 of 4 September 11, 2017
Product Specifications E15R05P19
Total Group Delay, maximum
70 ns
70 ns
Return Loss, minimum
24 dB
24 dB
RX Band Rejection, minimum
40 dB
40 dB
Input Power, RMS, maximum
100 W
100 W
Input Power, PEP, maximum
1000 W
1000 W
5th Order PIM, maximum
-150 dBc
-150 dBc
5th Order PIM Test Method
2 x 20 W CW tones
2 x 20 W CW tones
Frequency Range
763–775 MHz
763–775 MHz
Attenuation, minimum
40 dB
40 dB
Electrical Specifications, Band Reject
AISG Electrical Specifications Voltage, AISG Mode
10–30 Vdc
Default Protocol
AISG 2.0
Protocol
AISG 1.1 | AISG 2.0
AISG Carrier
2.176 MHz ± 100 ppm
AISG Connector
8-pin DIN Female
AISG Connector Standard
IEC 60130-9
dc Power/Alarm Electrical Specifications Voltage
10–30 Vdc
Voltage, CWA Mode
10–18 Vdc
dc Switching/Redundancy
Yes
Operating Current at Voltage
140 mA @ 12 V
Operating Current Tolerance
±15 mA
Alarm Current, CWA Mode
180–200 mA @ 10–18 V
Lightning Surge Current
10 kA
Lightning Surge Current Waveform 8/20 waveform
©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: May 19, 2017
page 2 of 4 September 11, 2017
Product Specifications E15R05P19
Block Diagram
Mechanical Specifications RF Connector Interface
7-16 DIN Female
Color
Gray
Finish
Painted
Mount Type
Pole
Mounting Pipe Hardware
Band clamps (4)
Wind Loading, maximum
75 lb/ft @ 70 mph
Wind Speed, maximum
241 km/h
|
150 mph
Height
290.0 mm
|
11.4 in
Width
252.5 mm | 9.9 in
Depth
162.0 mm | 6.4 in
Weight
12.5 kg
|
Wall
Dimensions
|
27.6 lb
Environmental Specifications Operating Temperature
-40 °C to +65 °C (-40 °F to +149 °F)
Ingress Protection Test Method
IEC 60529:2001, IP67
©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: May 19, 2017
page 3 of 4 September 11, 2017
Product Specifications E15R05P19
Outline Drawing
©2017 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: May 19, 2017
page 4 of 4 September 11, 2017