Transcript
Product Specifications 700008477 | N-004 004--DS DS--6F 6F--FSUOR
Low Smoke Zero Halogen Riser Distribution Cable, 4 fiber singleunit
Representative Image
General Specifications Cable Type
Distribution
Construction Type
Nonarmored
Subunit Type
Gelfree
Construction Materials Fiber Type Solution
OptiSPEED®, 62.5 µm multimode fiber (OM1)
Total Fiber Count
4
Fiber Type
OptiSPEED®, 62.5 µm multimode fiber (OM1)
Fiber Type, quantity
4
Jacket Color
Orange
Dimensions Cable Weight
14.1 lb/kft
Diameter Over Jacket
4.65 mm | 0.18 in
|
21.0 kg/km
Physical Specifications Minimum Bend Radius, loaded
7.0 cm | 2.8 in
Minimum Bend Radius, unloaded
4.6 cm | 1.8 in
Tensile Load, long term, maximum 45 lbf
|
Tensile Load, short term, maximum 150 lbf Vertical Rise, maximum
500.0 m
200 N |
667 N |
1640.4 ft
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 1 of 2 April 13, 2016
Product Specifications 700008477 | N 700008477 | N--004 004--DS DS--6F 6F--FSUOR
Flame Test Specifications Flame Test Listing
NEC OFNRLS (ETL) and c(ETL)
Flame Test Method
IEC 603323
|
IEC 607542
|
IEC 610342
|
IEEE 383
|
UL 1666
|
UL 1685
Environmental Specifications Environmental Space
Low Smoke Zero Halogen (LSZH)
Installation Temperature
30 °C to +60 °C (22 °F to +140 °F)
|
Riser
Operating Temperature
40 °C to +70 °C (40 °F to +158 °F)
Storage Temperature
40 °C to +70 °C (40 °F to +158 °F)
Mechanical Test Specifications Compression
10 N/mm | 57 lb/in
Compression Test Method
FOTP41
Flex
100 cycles
Flex Test Method
FOTP104
Impact
4.34 ft lb
|
5.88 Nm
Impact Test Method
FOTP25
|
IEC 607941 E4
Strain
See long and short term tensile loads
Strain Test Method
FOTP33
Twist
10 cycles
Twist Test Method
FOTP85
|
IEC 607941 E3 |
IEC 607941 E6
|
IEC 607941 E1
|
IEC 607941 E7
Environmental Test Specifications Heat Age
40 °C to +85 °C (40 °F to +185 °F)
Heat Age Test Method
IEC 607941 F9
Low High Bend
40 °C to +70 °C (40 °F to +158 °F)
Low High Bend Test Method
FOTP37
Temperature Cycle
40 °C to +70 °C (40 °F to +158 °F)
Temperature Cycle Test Method
FOTP3
| |
IEC 607941 E11 IEC 607941 F1
Qualification Specifications Cable Qualification Standards
ANSI/ICEA S83596
|
Telcordia GR409
Regulatory Compliance/Certifications Agency RoHS 2011/65/EU ISO 9001:2008
Classification Compliant Designed, manufactured and/or distributed under this quality management system
Included Products CS6FTB (Product Component—not orderable) — OptiSPEED® OM1 Multimode Fiber
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 2 of 2 April 13, 2016