Preview only show first 10 pages with watermark. For full document please download

Product Specifications 760004192 760004192    |       |    Zz--024

   EMBED


Share

Transcript

Product Specifications 760004192    |    Z-024 024--DS DS--8W 8W--FMUBK Indoor/Outdoor Low Smoke Zero Halogen Riser Distribution Cable, 24 fiber multi­unit  with 6 fiber subunits   Representative Image       General Specifications Cable Type  Distribution  Construction Type  Non­armored  Subunit Type  Gel­free    Construction Materials Fiber Type Solution  TeraSPEED®, zero water peak singlemode fiber (G.652.D, G.657.A1)  Total Fiber Count  24  Fiber Type  TeraSPEED®, zero water peak singlemode fiber (G.652.D, G.657.A1)  Fiber Type, quantity  24  Fibers per Subunit, quantity  6  Jacket Color  Black  Jacket UV Resistance  UV stabilized    Dimensions Buffer Tube/Subunit Diameter  5.50 mm | 0.22 in  Cable Weight  133.0 lb/kft Diameter Over Jacket  16.40 mm Subunit, quantity  4  | | 198.0 kg/km  0.65 in    Physical Specifications Minimum Bend Radius, loaded  24.6 cm | 9.7 in  Minimum Bend Radius, unloaded  16.4 cm | 6.5 in  Tensile Load, long term, maximum  180 lbf | Tensile Load, short term, maximum  600 lbf | Vertical Rise, maximum  413.0 m 801 N  2670 N  | 1355.0 ft    ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 1 of 3 May 1, 2016 Product Specifications 760004192   |   Z 760004192   |   Z--024 024--DS DS--8W 8W--FMUBK   Flame Test Specifications Flame Test Listing  NEC OFNR­LS (ETL) and c(ETL)  Flame Test Method  IEC 60332­3 | IEC 60754­2 | IEC 61034­2 | IEEE 383 | UL 1666 | UL 1685    Environmental Specifications Environmental Space  Low Smoke Zero Halogen (LSZH) Installation Temperature  ­30 °C to +60 °C (­22 °F to +140 °F)  | Riser  Operating Temperature  ­40 °C to +70 °C (­40 °F to +158 °F)  Storage Temperature  ­40 °C to +75 °C (­40 °F to +167 °F)    Mechanical Test Specifications Compression  126 lb/in | 22 N/mm  Compression Test Method  FOTP­41 Flex  100 cycles  Flex Test Method  FOTP­104 Impact  4.34 ft lb | 5.88 N­m  Impact Test Method  FOTP­25 | IEC 60794­1 E4  Strain  See long and short term tensile loads  Strain Test Method  FOTP­33 Twist  10 cycles  Twist Test Method  FOTP­85 Water Penentration  24 h  Water Penentration Test Method  FOTP­82 | IEC 60794­1 E3  | IEC 60794­1 E6  | IEC 60794­1 E1  | IEC 60794­1 E7  | IEC 60794­1 F5    Environmental Test Specifications Cable Freeze Test Method  IEC 60794­1 F15  Heat Age  ­40 °C to +85 °C (­40 °F to +185 °F)  Heat Age Test Method  IEC 60794­1 F9  Low High Bend  ­40 °C to +70 °C (­40 °F to +158 °F)  Low High Bend Test Method  FOTP­37 Temperature Cycle  ­40 °C to +70 °C (­40 °F to +158 °F)  Temperature Cycle Test Method  FOTP­3 | | IEC 60794­1 E11  IEC 60794­1 F1    Qualification Specifications Cable Qualification Standards  ANSI/ICEA S­104­696 | EN 187105 penetration) | Telcordia GR­409  | Telcordia GR­20 (water  Regulatory Compliance/Certifications Agency RoHS 2011/65/EU ISO 9001:2008 Classification Compliant Designed, manufactured and/or distributed under this quality management system   ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 2 of 3 May 1, 2016 Product Specifications 760004192   |   Z 760004192   |   Z--024 024--DS DS--8W 8W--FMUBK Included Products CS­8W­TB   (Product Component—not orderable)  — TeraSPEED® Singlemode Fiber  ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 3 of 3 May 1, 2016