Transcript
Product Specifications 760004192 | Z-024 024--DS DS--8W 8W--FMUBK
Indoor/Outdoor Low Smoke Zero Halogen Riser Distribution Cable, 24 fiber multiunit with 6 fiber subunits
Representative Image
General Specifications Cable Type
Distribution
Construction Type
Nonarmored
Subunit Type
Gelfree
Construction Materials Fiber Type Solution
TeraSPEED®, zero water peak singlemode fiber (G.652.D, G.657.A1)
Total Fiber Count
24
Fiber Type
TeraSPEED®, zero water peak singlemode fiber (G.652.D, G.657.A1)
Fiber Type, quantity
24
Fibers per Subunit, quantity
6
Jacket Color
Black
Jacket UV Resistance
UV stabilized
Dimensions Buffer Tube/Subunit Diameter
5.50 mm | 0.22 in
Cable Weight
133.0 lb/kft
Diameter Over Jacket
16.40 mm
Subunit, quantity
4
| |
198.0 kg/km 0.65 in
Physical Specifications Minimum Bend Radius, loaded
24.6 cm | 9.7 in
Minimum Bend Radius, unloaded
16.4 cm | 6.5 in
Tensile Load, long term, maximum 180 lbf
|
Tensile Load, short term, maximum 600 lbf
|
Vertical Rise, maximum
413.0 m
801 N 2670 N |
1355.0 ft
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 1 of 3 May 1, 2016
Product Specifications 760004192 | Z 760004192 | Z--024 024--DS DS--8W 8W--FMUBK
Flame Test Specifications Flame Test Listing
NEC OFNRLS (ETL) and c(ETL)
Flame Test Method
IEC 603323
|
IEC 607542
|
IEC 610342
|
IEEE 383
|
UL 1666
|
UL 1685
Environmental Specifications Environmental Space
Low Smoke Zero Halogen (LSZH)
Installation Temperature
30 °C to +60 °C (22 °F to +140 °F)
|
Riser
Operating Temperature
40 °C to +70 °C (40 °F to +158 °F)
Storage Temperature
40 °C to +75 °C (40 °F to +167 °F)
Mechanical Test Specifications Compression
126 lb/in | 22 N/mm
Compression Test Method
FOTP41
Flex
100 cycles
Flex Test Method
FOTP104
Impact
4.34 ft lb
|
5.88 Nm
Impact Test Method
FOTP25
|
IEC 607941 E4
Strain
See long and short term tensile loads
Strain Test Method
FOTP33
Twist
10 cycles
Twist Test Method
FOTP85
Water Penentration
24 h
Water Penentration Test Method
FOTP82
|
IEC 607941 E3 |
IEC 607941 E6
|
IEC 607941 E1
|
IEC 607941 E7
|
IEC 607941 F5
Environmental Test Specifications Cable Freeze Test Method
IEC 607941 F15
Heat Age
40 °C to +85 °C (40 °F to +185 °F)
Heat Age Test Method
IEC 607941 F9
Low High Bend
40 °C to +70 °C (40 °F to +158 °F)
Low High Bend Test Method
FOTP37
Temperature Cycle
40 °C to +70 °C (40 °F to +158 °F)
Temperature Cycle Test Method
FOTP3
| |
IEC 607941 E11 IEC 607941 F1
Qualification Specifications Cable Qualification Standards
ANSI/ICEA S104696 | EN 187105 penetration) | Telcordia GR409
|
Telcordia GR20 (water
Regulatory Compliance/Certifications Agency RoHS 2011/65/EU ISO 9001:2008
Classification Compliant Designed, manufactured and/or distributed under this quality management system
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 2 of 3 May 1, 2016
Product Specifications 760004192 | Z 760004192 | Z--024 024--DS DS--8W 8W--FMUBK
Included Products CS8WTB (Product Component—not orderable) — TeraSPEED® Singlemode Fiber
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 3 of 3 May 1, 2016