Transcript
Product Specifications 810008858/DB | D-024 024--LN LN--8W 8W--F123G/AJ
Single Alternative Jacket AllDielectric, GelFree, Outdoor Stranded Loose Tube Cable
Representative Image
General Specifications Cable Type
Stranded loose tube
Construction Type
Nonarmored
Subunit Type
Gelfree
Construction Materials Fiber Type Solution
LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)
Jacket Material
Alternative jacket PE
Total Fiber Count
24
Fiber Type
LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)
Fiber Type, quantity
24
Fibers per Subunit, quantity
12
Jacket Color
Black
Jacket UV Resistance
UV stabilized
Dimensions Buffer Tube/Subunit Diameter
2.50 mm | 0.10 in
Cable Weight
66.0 kg/km
Diameter Over Jacket
10.10 mm
Filler, quantity
3
Subunit, quantity
2
| |
45.0 lb/kft 0.40 in
Physical Specifications Minimum Bend Radius, loaded
15.2 cm | 6.0 in
Minimum Bend Radius, unloaded
10.1 cm | 4.0 in
Tensile Load, long term, maximum 800 N
|
180 lbf
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 1 of 3 May 3, 2016
Product Specifications 810008858/DB | D 810008858/DB | D--024 024--LN LN--8W 8W--F123G/AJ
Tensile Load, short term, maximum 2700 N Vertical Rise, maximum
|
607 lbf
1234.0 m
|
4048.0 ft
Environmental Specifications Environmental Space
Aerial, lashed
Installation Temperature
30 °C to +70 °C (22 °F to +158 °F)
|
Buried
Operating Temperature
40 °C to +70 °C (40 °F to +158 °F)
Storage Temperature
40 °C to +75 °C (40 °F to +167 °F)
Mechanical Test Specifications Compression
22 N/mm | 125 lb/in
Compression Test Method
FOTP41
Flex
35 cycles
Flex Test Method
FOTP104
Impact
2.94 Nm | 2.17 ft lb
Impact Test Method
FOTP25
Strain
See long and short term tensile loads
Strain Test Method
FOTP33
Twist
10 cycles
Twist Test Method
FOTP85
Water Penentration
24 h
Water Penentration Test Method
FOTP82
|
IEC 607941 E3 |
|
IEC 607941 E6 IEC 607941 E4
|
IEC 607941 E1
|
IEC 607941 E7
|
IEC 607941 F5
Environmental Test Specifications Cable Freeze
2 °C
Cable Freeze Test Method
FOTP98
|
28 °F
Heat Age
40 °C to +85 °C (40 °F to +185 °F)
Heat Age Test Method
IEC 607941 F9
Low High Bend
30 °C to +60 °C (22 °F to +140 °F)
Low High Bend Test Method
FOTP37
Temperature Cycle
40 °C to +70 °C (40 °F to +158 °F)
Temperature Cycle Test Method
FOTP3
|
| |
IEC 607941 F15
IEC 607941 E11 IEC 607941 F1
Qualification Specifications Cable Qualification Standards
ANSI/ICEA S87640
|
EN 187105
|
Telcordia GR20
Regulatory Compliance/Certifications Agency RoHS 2011/65/EU ISO 9001:2008
Classification Compliant Designed, manufactured and/or distributed under this quality management system
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 2 of 3 May 3, 2016
Product Specifications 810008858/DB | D 810008858/DB | D--024 024--LN LN--8W 8W--F123G/AJ
Included Products CS8WLT (Product Component—not orderable) — TeraSPEED® OS2 Singlemode Fiber
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 3 of 3 May 3, 2016