Transcript
Product Specifications 810008871/DB | D-072 072--LA LA--8W 8W--F123G/AJ
Single Alternative Jacket/Single Armor, GelFree, Outdoor Stranded Loose Tube Cable l
Corrugated steel tape armor is strong yet flexible, providing additional crush and rodent protection
Representative Image
General Specifications Cable Type
Stranded loose tube
Construction Type
Armored
Subunit Type
Gelfree
Construction Materials Fiber Type Solution
LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)
Jacket Material
Alternative jacket PE
Total Fiber Count
72
Armor Type
Corrugated steel
Fiber Type
LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)
Fiber Type, quantity
72
Fibers per Subunit, quantity
12
Jacket Color
Black
Jacket UV Resistance
UV stabilized
Dimensions Buffer Tube/Subunit Diameter
2.50 mm | 0.10 in
Cable Weight
122.0 kg/km
|
Diameter Over Jacket
11.90 mm
0.47 in
Subunit, quantity
6
|
82.0 lb/kft
Physical Specifications Minimum Bend Radius, loaded
17.9 cm | 7.0 in
Minimum Bend Radius, unloaded
11.9 cm | 4.7 in
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 1 of 2 April 30, 2016
Product Specifications 810008871/DB | D 810008871/DB | D--072 072--LA LA--8W 8W--F123G/AJ Tensile Load, long term, maximum 800 N
|
Tensile Load, short term, maximum 2700 N Vertical Rise, maximum
180 lbf |
607 lbf
672.0 m
|
2203.0 ft
Environmental Specifications Environmental Space
Aerial, lashed
|
Buried
Installation Temperature
30 °C to +70 °C (22 °F to +158 °F)
Operating Temperature
40 °C to +70 °C (40 °F to +158 °F)
Storage Temperature
40 °C to +75 °C (40 °F to +167 °F)
Mechanical Test Specifications Compression
44 N/mm | 250 lb/in
Compression Test Method
FOTP41
Flex
35 cycles
Flex Test Method
FOTP104
Impact
2.94 Nm | 2.17 ft lb
Impact Test Method
FOTP25
Strain
See long and short term tensile loads
Strain Test Method
FOTP33
Twist
10 cycles
Twist Test Method
FOTP85
Water Penentration
24 h
Water Penentration Test Method
FOTP82
|
IEC 607941 E3 |
|
IEC 607941 E6 IEC 607941 E4
|
IEC 607941 E1
|
IEC 607941 E7
|
IEC 607941 F5
Environmental Test Specifications Cable Freeze
2 °C
|
28 °F
Cable Freeze Test Method
FOTP98
Heat Age
40 °C to +85 °C (40 °F to +185 °F)
Heat Age Test Method
IEC 607941 F9
Low High Bend
30 °C to +60 °C (22 °F to +140 °F)
Low High Bend Test Method
FOTP37
Temperature Cycle
40 °C to +70 °C (40 °F to +158 °F)
Temperature Cycle Test Method
FOTP3
|
| |
IEC 607941 F15
IEC 607941 E11 IEC 607941 F1
Qualification Specifications Cable Qualification Standards
ANSI/ICEA S87640
|
EN 187105
|
Telcordia GR20
Regulatory Compliance/Certifications Agency RoHS 2011/65/EU ISO 9001:2008
Classification Compliant Designed, manufactured and/or distributed under this quality management system
Included Products DB8WLT (Product Component—not orderable) — LightScope ZWP® Singlemode Fiber
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 2 of 2 April 30, 2016