Transcript
Product Specifications 8108074/DB | P-072 072--LN LN--8W 8W--F12BK/25D
Indoor/Outdoor, Single Jacket AllDielectric, Plenum Rated, GelFree, Stranded Loose Tube Cable, PVDF jacket is resistant to jet fuel, oils, and many chemicals
Representative Image
General Specifications Cable Type
Stranded loose tube
Construction Type
Nonarmored
Subunit Type
Gelfree
Construction Materials Fiber Type Solution
LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)
Total Fiber Count
72
Fiber Type
LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)
Fiber Type, quantity
72
Fibers per Subunit, quantity
12
Jacket Color
Black
Jacket UV Resistance
UV stabilized
Dimensions Buffer Tube/Subunit Diameter
2.50 mm | 0.10 in
Cable Weight
103.0 kg/km
|
Diameter Over Jacket
10.00 mm
0.39 in
Subunit, quantity
6
|
69.0 lb/kft
Physical Specifications Minimum Bend Radius, loaded
15.1 cm | 5.9 in
Minimum Bend Radius, unloaded
10.0 cm | 3.9 in
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 1 of 3 May 1, 2016
Product Specifications 8108074/DB | P 8108074/DB | P--072 072--LN LN--8W 8W--F12BK/25D
Tensile Load, long term, maximum 180 lbf
|
Tensile Load, short term, maximum 2700 N
|
Vertical Rise, maximum
800 N 607 lbf
2598.0 ft
|
792.0 m
Flame Test Specifications Flame Test Listing
NEC OFNP (ETL) and c(ETL)
Flame Test Method
NFPA 262
Environmental Specifications Environmental Space
Plenum
Installation Temperature
30 °C to +70 °C (22 °F to +158 °F)
Operating Temperature
40 °C to +70 °C (40 °F to +158 °F)
Storage Temperature
40 °C to +75 °C (40 °F to +167 °F)
Mechanical Test Specifications Compression
125 lb/in | 22 N/mm
Compression Test Method
FOTP41
Flex
35 cycles
Flex Test Method
FOTP104
Impact
2.17 ft lb
|
2.94 Nm
Impact Test Method
FOTP25
|
IEC 607941 E4
Strain
See long and short term tensile loads
Strain Test Method
FOTP33
Twist
10 cycles
Twist Test Method
FOTP85
Water Penentration
24 h
Water Penentration Test Method
FOTP82
|
IEC 607941 E3 |
IEC 607941 E6
|
IEC 607941 E1
|
IEC 607941 E7
|
IEC 607941 F5
Environmental Test Specifications Cable Freeze
2 °C
Cable Freeze Test Method
FOTP98
|
28 °F
Heat Age
40 °C to +85 °C (40 °F to +185 °F)
Heat Age Test Method
IEC 607941 F9
Low High Bend
30 °C to +60 °C (22 °F to +140 °F)
Low High Bend Test Method
FOTP37
Temperature Cycle
40 °C to +70 °C (40 °F to +158 °F)
Temperature Cycle Test Method
FOTP3
|
| |
IEC 607941 F15
IEC 607941 E11 IEC 607941 F1
Qualification Specifications Cable Qualification Standards
ANSI/ICEA S104696
|
EN 187105
|
Telcordia GR409
Regulatory Compliance/Certifications Agency RoHS 2011/65/EU
Classification Compliant
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 2 of 3 May 1, 2016
Product Specifications 8108074/DB | P 8108074/DB | P--072 072--LN LN--8W 8W--F12BK/25D ISO 9001:2008
Designed, manufactured and/or distributed under this quality management system
Included Products DB8WLT (Product Component—not orderable) — LightScope ZWP® Singlemode Fiber
©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016
page 3 of 3 May 1, 2016