Preview only show first 10 pages with watermark. For full document please download

Product Specifications 8108249/db 8108249/db    |       |    Pp--036

   EMBED


Share

Transcript

Product Specifications 8108249/DB    |    P-036 036--LN LN--8W 8W--F12BK/25D Indoor/Outdoor, Single Jacket All­Dielectric, Plenum Rated, Gel­Free, Stranded Loose  Tube Cable, PVDF jacket is resistant to jet fuel, oils, and many chemicals   Representative Image       General Specifications Cable Type  Stranded loose tube  Construction Type  Non­armored  Subunit Type  Gel­free    Construction Materials Fiber Type Solution  LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)  Total Fiber Count  36  Fiber Type  LightScope® ZWP®, zero water peak singlemode fiber (G.652.D, G.657.A1)  Fiber Type, quantity  36  Fibers per Subunit, quantity  12  Jacket Color  Black  Jacket UV Resistance  UV stabilized    Dimensions Buffer Tube/Subunit Diameter  2.50 mm | 0.10 in  Cable Weight  92.0 kg/km Diameter Over Jacket  9.70 mm | 0.38 in  Filler, quantity  2  Subunit, quantity  3  | 62.0 lb/kft    Physical Specifications Minimum Bend Radius, loaded  14.5 cm | 5.7 in  ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 1 of 3 April 14, 2016 Product Specifications 8108249/DB   |   P 8108249/DB   |   P--036 036--LN LN--8W 8W--F12BK/25D Minimum Bend Radius, unloaded  3.8 in | 9.7 cm  Tensile Load, long term, maximum  800 N | Tensile Load, short term, maximum  2700 N Vertical Rise, maximum  180 lbf  | 607 lbf  888.0 m | 2913.0 ft    Flame Test Specifications Flame Test Listing  NEC OFNP (ETL) and c(ETL)  Flame Test Method  NFPA 262    Environmental Specifications Environmental Space  Plenum  Installation Temperature  ­30 °C to +70 °C (­22 °F to +158 °F)  Operating Temperature  ­40 °C to +70 °C (­40 °F to +158 °F)  Storage Temperature  ­40 °C to +75 °C (­40 °F to +167 °F)    Mechanical Test Specifications Compression  125 lb/in | 22 N/mm  Compression Test Method  FOTP­41 Flex  35 cycles  Flex Test Method  FOTP­104 Impact  2.17 ft lb | 2.94 N­m  Impact Test Method  FOTP­25 | IEC 60794­1 E4  Strain  See long and short term tensile loads  Strain Test Method  FOTP­33 Twist  10 cycles  Twist Test Method  FOTP­85 Water Penentration  24 h  Water Penentration Test Method  FOTP­82 | IEC 60794­1 E3  | IEC 60794­1 E6  | IEC 60794­1 E1  | IEC 60794­1 E7  | IEC 60794­1 F5    Environmental Test Specifications Cable Freeze  ­2 °C | 28 °F  Cable Freeze Test Method  FOTP­98 Heat Age  ­40 °C to +85 °C (­40 °F to +185 °F)  Heat Age Test Method  IEC 60794­1 F9  Low High Bend  ­30 °C to +60 °C (­22 °F to +140 °F)  Low High Bend Test Method  FOTP­37 Temperature Cycle  ­40 °C to +70 °C (­40 °F to +158 °F)  Temperature Cycle Test Method  FOTP­3 | | | IEC 60794­1 F15  IEC 60794­1 E11  IEC 60794­1 F1    Qualification Specifications Cable Qualification Standards  ANSI/ICEA S­104­696 | EN 187105 | Telcordia GR­409  Regulatory Compliance/Certifications Agency Classification ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 2 of 3 April 14, 2016 Product Specifications 8108249/DB   |   P 8108249/DB   |   P--036 036--LN LN--8W 8W--F12BK/25D RoHS 2011/65/EU ISO 9001:2008 Compliant Designed, manufactured and/or distributed under this quality management system Included Products DB­8W­LT   (Product Component—not orderable)  — LightScope ZWP® Singlemode Fiber  ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 3 of 3 April 14, 2016