Product Specifications Dcu Dcu--10 10

   EMBED


Share

Transcript

Product Specifications DCU DCU--10 Data Center on Demand™ 10­Rack Solution, 400 Vac input power, 0–35 kW per rack   General Specifications Average Annual Power Usage Effectiveness (pPUE)  1.03–1.06  Brand  Data Center on Demand™  Ordering Note  For your customized solution—Call your local CommScope  representative    Main Unit Options Input Voltage Range  380–415 Vac Power Redundancy  Tier 2 Cooling  Evaporative cooling Cold Weather Package  Not equipped | Temperatures to ­10 °C (14 °F) from ­10 °C to ­40 °C (14 °F to ­40 °F)  Vestibule  Not equipped Door Security  Keyed door locks Surveillance  Not equipped Fire Detection  Aspirating smoke detector (ASD) Fire Suppression  Not equipped Air Filtration  MERV 11 filters | MERV 15 filters phase | Salt fog  | MERV 16 filters Replacement Parts  Not equipped | Recurring maintenance parts kit  | | 208–240 Vac  Tier 3  | | | | | Chilled water cooling Single width | | | DX cooling  | Temperatures  Double width  Electric door locks with card readers  Closed circuit TV camera with DVR system  | Spot detectors  Flooding with fire protection fluid  Critical parts kit | Gas    Main Unit Specifications Racks or Cabinets per Unit, maximum  10  Unit Width  6300 mm | 248 in  Unit Length  7080 mm | 279 in  Unit Height  3740 mm | 147 in  Unit Net Weight  22499 kg | 49602 lb  Cold Aisle Width  1446.0 mm Hot Aisle Width  791.0 mm Hot Aisle Width Note  Width assumes a rack length of 1000 mm  White Space Width  6134 mm Output Power Range per Rack  0–35 kW  | | 56.9 in  31.1 in  | 241 in    Vestibule Specifications Single Width Vestibule Width  2300 mm | 91 in  Single Width Vestibule Length  7080 mm | 279 in  Single Width Vestibule Height  3740 mm | 147 in  ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 1 of 2 May 2, 2016 Product Specifications DCU DCU--10 Single Width Vestibule Net Weight  4580 kg Double Width Vestibule Width  5700 mm | | 10097 lb  224 in  Double Width Vestibule Length  7080 mm | 279 in  Double Width Vestibule Height  3740 mm | 147 in  Double Width Vestibule Net Weight  10545.00 kg | 23247.75 lb    Environmental Specifications Qualification Standard  IEC 60529:2001, IP55 Qualification Standard Note  IEC 60529, IP55 does not apply to the mixing  chamber | Achievement of this rating may require a filter with a  higher MERV rating  | NFPA 70  Safety Standard  CE  ©2016 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks, respectively, of CommScope. All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: January 16, 2016 page 2 of 2 May 2, 2016