Transcript
Products Catalog
2015
MADE TO MAKE IT WELL DONE.
INTRODUCTION
MISSION
Turn the need for xing and tying in practical, safe and economical experience.
CERTIFICATION SCOPE
• ISO 9001:2008
• ISO/TS 16949:2009
• CRCC
Technical Information We produce cable ties and fasteners with different types of polymers, which have specific features and an indication of use for various environments.
SUMMARY 05 Technical Information 11 Standard Cable ties 16 Cable ties Accessories 21 Special Cable ties 29 Stainless Steel Cable ties 35 Fasteners 40 Cable Organizers 43 Heat Shrinkables 57 Connectors and Terminals
05
Technical Information
Polyamide 6.6 properties
Moisture index in polyamides
Polyamides are thermoplastic synthetic materials that can be molded by heating without providing chemical decomposition or other changes in their properties. They are also known as Nylon, name used by Dupont, who synthesized the first polyamide in 1935 by the chemist Wallace Hume Carothers. Polyamide 6.6 has features that allow the manufacture of cable ties and fasteners with high tensile strength, mechanical strength; and desirable flexibility and surface hardness. It is the most common polyamide in the manufacture of FRONTEC cable ties and fasteners, because its characteristics are suitable for a high range of applications. PA 6.6 molecules are composed of two basic units with six carbon atoms in each of them:
[-NH(CH2)6NH - CO(CH2)4CO-]
The polyamides are hygroscopic materials, they absorb and release water. The moisture level of the cable ties is very important, because it affects their flexibility and their tensile strength. Polyamide 6.6 stabilizes its moisture index around 2.5% when subjected to a controlled atmosphere of 23 °C and 50% relative air humidity.The time required for the cable ties to acquire this moisture content ranges from 7 to 50 days depending on the dimensions of the piece. When the cable ties are used, the ideal is that its moisture content is around 2.5%. Once applied, once the trigger will be static in the grooves of the cable tie body, the changes in moisture index will not cause significant changes in the mechanical properties of the parts. FRONTEC cable ties and fasteners are packed in suitable plastic bags and are only sold in the market when its moisture index is around 2.5%. For this reason, it is recommended that products are kept in their original packages and used as soon as the packages are open.It is also recommended that, during the storage of cable ties and fasteners, the products do not suffer exposure to sun rays or are stored near heat sources.The ideal storage should be at 23 ° C with relative air humidity of 50%.
Polyamide 4.6 properties Polyamide 4.6 has a high heat resistance without the need for adding special additives. It is used in the manufacture of FRONTEC cable ties and fasteners for use in environments with temperatures up to 135 °C with peaks up to 150 °C. PA 4.6 molecules are composed of two basic units with four carbon atoms in one of them and six in the other:
[-NH(CH2)4NH - CO(CH2)4CO-]
Raw material technical parameters Material Nylon 6.6 (PA6.6) Nylon 6.6 UV estabilizado a raios ultravioleta (PA6.6 UV) Nylon 6.6 HS estabilizado ao calor (PA6.6 HS) Nylon 6.6 V0 (PA6.6 V0) Nylon 4.6 (PA 4.6)
06
Operating Temperature -40ºC
-40ºC
-40ºC
-40ºC
85ºC
Flammability UL94 V2
Properties of the material
UL94 V2
105ºC
UL94 V2
- similar characteristics to PA 6.6, but with added durability at constant hight temperature applications; - recommended for close to vehicular engine applications.
85ºC
UL94 V0
- similar characteristics to PA 6.6, and comply with UL 94V0 standard and low levels of toxic gas and acids generated by the fire.
UL94 V2
- excellent chemical resistance; - higher rigidity and dimensional stability, even at hight temperatures.
-40ºC 135ºC (picos de até 150ºC)
The cable ties in the natural color (page 12) are not suitable for applications with exposure to sunlight for long periods of time. The cable ties in black (page 12) are doped with carbon black and, therefore, have a good resistance to ultraviolet rays (UV). Experience has shown good performance in sun exposure of up to 3 years. The cable ties with UV protection (page 13) are doped with special components that provide greater resistance to weathering and ultraviolet rays (UV), being indicated for applications exposed to sunlight for higher time. They are tested according to the ASTM G155:13 standards, that simulates a condition of approximately 10 years exposure to weather.The cable tie features (tensile strength, color, flexibility and texture) should remain unchanged after subjected to this test. To identify whether a cable tie in black has UV resistance or not, a faster and simpler assay can be done, consisting in tuning a part of the cable tie tape (between 0.2 and 0.3 mm) and look to the light through this area.The cable tie with UV protection does not allow light to pass through and the cable tie without UV protection is a little t ranslucent in tuned area.
- high traction and abrasion resistance. - high mecanical resistance; - excellent flexibility and surface hardness. - similar characteristics to PA 6.6, but resistant to ultraviolet rays. - recommended for use in environments exposed to sunlight.
85ºC
Cable ties with protection against ultraviolet rays (UV)
UV Protection
No UV Protection
07
Technical Information Strenght (Kgf)
Temperature resistance The polyamides used for manufacturing cable ties are sensitive to high or low temperatures. Exposure to very high or low temperatures can break the molecular chain, causing low mechanical strength, fragility and sensitivity to vibration. The maximum temperature recommended for the installation of Polyamide 6.6 cable tie is 60 °C, however the maximum temperature of continuous use is 85 ºC. The minimum temperature for the use of polyamide 6.6 cable ties is -40 °C. However, when they are applied, it is recommended that the temperature is above -10 °C. When the cable ties are used in high temperature regime, it is recommended the use of cable ties produced with heat-stabilized polyamide 6.6 (PA 6.6 HS) or produced from polyamide 4.6.
Sample
Flammability The most popular standard for assessing the behavior of polymers against the flame is the UL 94 (Underwriters Laboratories).This test classifies the material based on the speed of combustion, the flame extinction time and the trend of flame propagation by dripping. Classification begins with the HB class, lower level, which identifies the material as low burning rate.V2, V1 and V0 classes identify materials as self-extinguishing. HB (horizontal burning)- According to UL 94, the material is classified as HB, considering two test samples: • Combustion of 38.1 mm/in for a 3.2 mm thick specimen. • Combustion of 63.5 mm/ min for a <3.2 mm thick specimen. V2 (vertical burning) - The flame is extinguished within 30 seconds with dripping. V1 (vertical burning) - The flame is extinguished within 30 seconds without dripping. V0 (vertical burning) - The flame is extinguished within 10 seconds without dripping.
Traction resistance All cable ties lots produced by FRONTEC are tested by sampling. The results are available in reports containing the values obtained in each test. The minimum breakdown voltage is the load that a cable tie must support without the occurrence of its break.
The cable tie is fixed on a mandrel with a diameter defined for each cable tie model.
08
Minimum Strenght
The mandrel opens with constant speed.
The load at which the cable tie breaks down is measured and recorded in software that provides the test data in charts as shown on the next page.
The chart above represents the traction resistance test performed on 10 samples of the cable tie F7040.The minimum break voltage expected is 54.4 kgf and the result showed values close to 80 kgf (the result was 47% higher than specified in the catalog).
Traceability All products manufactured by FRONTEC have individual traceability for production batch, covering the various stages of the production process with the following information: • Lot of raw materials (including the vendor’s report); • Used machine; • Operator and time of manufacture; • Injection parameters used in the manufacture; • Data from the gravimetric distributor informing the dosages of the raw material components; • Records with date and time of testing, verification, inspection, wastes, operators, setup and stops in the production; • Release report issued by the quality sector; • Storage location in stock; • Data related to the separation and billing (who separated the order, date, invoice number, customer etc.).
Cable ties preservation
For proper preservation of the cable tie, it is recommended to storage at a temperature between 10 and 40 °C and relative air humidity between 30% and 70%.
The cable tie must be used as soon as possible after opening the packaging (plastic bag) if the humidity is below 30%.
Avoid keeping the cable tie near heat sources, as this may change the humidity of cable ties and its features.
Do not place or expose the cable ties in the ultraviolet (UV) rays, as they may change their structure, making them fragile.
09
Resistance to chemicals Chemicals such as acids, bases, salts, alcohols, phenols, gas, among others, may deteriorate the raw material used in the cable tie,changing its properties and life cycle. See the table of chemicals resistance.
Chemical agent
Conc.
Resist.
Chemical agent
Conc.
Resist.
Acetaldehyde - aqueous solution Acetamide - aqueous solution Amyl acetate Butyl acetate 100% Methyl acetate Lead acetate - water solution Acetone Acetic acid - concentrated Acetic acid - aqueous solution Benzoic acid - saturated aqueous solution Bóric acid - aqueous solution Butyric acid Citric acid - aqueous solution Hydrochloric acid - aqueous solution Hydrochloric acid - aqueous solution Hydrochloric acid - aqueous solution
40% 50% 100% 100% 100% 10% 100%
1%
average
Aluminum choride - aqueous solution Barium chloride - aqueous solution Calcium chloride - aqueous solution Calcium chloride - aqueous solution Ethyl chloride Methyl chloride Magnesium chloride - aqueous solution Sodium chloride - aqueous solution Thionyl chloride Vinyl chloride Zinc chloride Ferric chloride - aqueous solution Decalin Diacetone alcohol Ethylene dichloride Diethanolamine Dimethylformamide
10% 10% 10% 20% 100% 100% 10% 10%
10% 100% 10% 2% 10% 36%
average good good good good average good low low average average average limited limited low soluble
100%
good good good soluble average limited good good low good average good good good good good good
10% 10% 85% 10% 10% 90%
low low soluble low average low low good average good soluble limited low average good good average good good average limited average average average average good limited soluble average limited good low average good average average average good good good good good good good low good average low
Acetic ether
100%
good
Ethyl ether Glycol ether Heptane Hexane Phenol - aqueous solution Formaldehyde - aqueous solution Formamide Sodium phosphate - aqueous solution Butyl glycol Ammonium hydroxide - aqueous solutioon Magnesium hydroxide - aqueous solution Potassium hydroxide - aqueous solutioon Potassium hydroxide - aqueous solution Potassium hydroxide - aqueous solutioon Sodium hypochlorite - aqueous solution Isooctane Mercury Methyl ethyl ketone Methyl isobutyl ketone Nafteno Potassium nitrate - aqueous solution Sodium nitrate - aqueous solution Nitrobenzene Nitromethane Mineral oil Zinc oxide Octyl phthalate Ozone Perchlorethylene Hydrogen peroxide - aqueous solution Hydrogen peroxide - aqueous solution Hydrogen peroxide - aqueous solution Hydrogen peroxide - aqueous solution Petroleum Magnesium salts - aqueous solution Copper salts - aqueous solution Caustic soda - aqueous solution Caustic soda- aqueous solution Caustic soda - aqueous solution Aluminium sulphate - aqueous solution Copper sulphate - aqueous solution Sodium sulphate - aqueous solution Carbon disulfide Hydrogen sulfide - aqueous solution Lead stearate Carbon tetrachloride Trichlorethylene
100%
good good good average soluble good average good average good good good good average good good good good good good good good average average good good good low low limited low low low good good good good good average good good good good low good good average
Chromic acid - aqueous solution Chromic acid - aqueous solution Formic acid - aqueous solution Formic acid - aqueous solution Phthalic acid - aqueous solution Lactic acid - aqueous solution Lactic acid - aqueous solution Nitric acid Oleic acid 100% good Oxalic acid - aqueous solution Salicílic acid Sulfuric acid - concentrated Sulfuric acid - aqueous solution Sulfuric acid - aqueous solution Tartaric acid Tartaric acid - aqueous solution Water (marine / of river / drinkable / distilled) Clorinated water Acrylonitrile Fusel oil Butyl alcohol Benzyl alcohol Ethanol / ethyl alcohol Isopropyl alcohol Methyl alcohol Propyl alcohol Ammonia Ammonia - gas Acetic anhydride - concentrated Aniline Benzaldehyde Benzene Mercuric chloride - aqueous solutiona Potassium bichromate - aqueous solution Sodium bisulfate - aqueous solution Bitumen Potassium bromide - aqueous solutiona Brometo de sódio - aqueous solution Butane Butyl phthalate Camphor Potassium carbonate Sodium carbonate - aqueous solution Cyclohexane Chlorine gas Chlorine gas Clorobenzene Clorobromometano Chloroform 100% low Clorofórmio
10%
100% 10% 100% 98% 2% 10% 10% 100% 100% 100% 100% 96% 100% 10% 100% 100% 100% 6% 5% 10% 10% 10% 100% 100% 10% 100% 100% 100% 100%
100% 10% 10%
30% 10% 100% 10% 10% 5% 10% 50%
10% 5% 100% 100%
0,5% 1% 3% 30% 10% 10% 5% 10% 50% 10% 10% 10% 100% 100%
Standard Cable ties We make various cable ties sizes and with different polymers, acColording to the best use indication.We produce with the best materials via the injection of the next generation.
Foto de abertura 21 x 18 cm
Good - good resistance without changes in weight and volume Average – average resistance with a significant loss of weight and volume if used for a long time Limited - limited resistance, can be used for a short period of time Low - low resistance. The material is very worn out.
10
11
Abraçadeiras Convencionais
Standard Cable tie 6.6
PA Cable tie 6.6 Resistant to weathering (UV)
Material: PA 6.6 Use temperature: 40 °C to 85 °C Flammability: UL94 V2
Material: PA 6.6 with anti-UV additives Use temperature: -40°C to 85°C Flammability: UL94 V2 FRONTEC manufactures a nylon cable ties line specially developed to resist UV and weathering. They can be used for long periods of time exposed to the sun (over 10 years). These cable ties are produced with Nylon 6.6 and additives that prevent the disruption of the molecular structure of the piece, providing resistance when used outdoors. The sun resistant cable ties are tested in accordance with ASTM G155 13 standard.
Group
12
Lenght X width (mm)
F7008
82 X 2,3
F7010
108 X 2,5
F7014
140 X 2,5
F7019
209 X 2,5
F7015
151 X 3,7
F7020
202 X 3,7
F7031 F7037
300 X 3,6 370 X 3,6
F7012
125 X 4,8
F7023
200 X 4,8
F7024
238 X 4,8
F7028
283 X 4,8
F7039
400 X 4,8
F7030
300 X 7,6
F7040
398 X 7,6
F7053
535 X 8,8
F7076
765 X 8,8
F70109
1095 X 8,8
F7054
536 X 13,7
Complete Reference
Color
F7008NYNA F7008NYPR F7010NYNA F7010NYPR F7014NYNA F7019NYNA F7019NYPR F7015NYNA F7015NYPR F7020NYNA F7020NYPR F7031NYNA F7037NYNA F7012NYNA F7012NYPR F7023NYNA F7023NYPR F7024NYNA F7024NYPR F7028NYNA F7028NYPR F7039NYNA F7039NYPR F7030NYNA F7030NYPR F7040NYNA F7040NYPR F7053NYNA F7053NYPR F7076NYNA F7076NYPR F70109NYNA F70109NYPR F7054NYNA F7054NYPR
natural black natural black natural natural black natural black natural black natural natural natural black natural black natural black natural black natural black natural black natural black natural black natural black natural black natural black
Ø Maximum Bundle
Minimum Tensile Strenght Kgf
lbs
N
8,2
18
60
13,6
30
135
16 22 33 55 37 51 76 102
Lenght X width (mm)
28 51
Complete Reference
Color
Ø Maximum Bundle
82 X 2,3
F7008UVPR
black
16
108 X 2,5
F7010UVPR
black
22
209 X 2,5
F7019UVPR
black
55
151 X 3,7
F7015UVPR
black
37
76
202 X 3,7
F7020UVPR
black
51
125 X 4,8
F7012UVPR
black
28
114
200 X 4,8
F7023UVPR
black
51
80
238 X 4,8
F7024UVPR
black
60
283 X 4,8
F7028UVPR
black
76
400 X 4,8
F7039UVPR
black
114
300 X 7,6
F7030UVPR
black
80
398 X 7,6
F7040UVPR
black
110
60
110
22,7
54,4
50
120
225
535
147 220
68
150
670
330 147
115
250
1115
535 X 8,8
F7053UVPR
black
147
765 X 8,8
F7076UVPR
black
220
1095 X 8,8
F70109UVPR
black
330
536 X 13,7
F7054UVPR
black
147
Minimum Tensile Strenght Kgf
lbs
N
8,2
18
80
13,6
30
135
22,7
50
225
54,4
120
535
68
150
670
115
250
1115
13
Abraçadeiras Convencionais
Color Cable Ties Resistant to weathering (UV)
PA Cable tie 6.6 for High Temperature (HS) Material: Nylon 6.6 HS Use temperature: -40°C to 105°C Flammability: UL94 V2
Material: PA 6.6 with anti-UV additives Use temperature: -40°C to 85°C Flammability: UL94 V2
Group
F7010
F7015
F7023
F7028
F7039
F7040
This cable ties line is produced from heat-stabilized polyamide 6.6 and injection parameters for use in environments subject to constant temperature regimes near 100 °C.
Lenght X width (mm)
Complete Reference
Color
108 X 2,5 108 X 2,5 108 X 2,5 108 X 2,5 108 X 2,5 151 X 3,7 151 X 3,7 151 X 3,7 151 X 3,7 151 X 3,7 200 X 4,8 200 X 4,8 200 X 4,8 200 X 4,8 200 X 4,8 283 X 4,8 283 X 4,8 283 X 4,8 283 X 4,8 400 X 4,8 400 X 4,8 400 X 4,8 400 X 4,8 398 X 7,6 398 X 7,6 398 X 7,6 398 X 7,6
F7010UVAM F7010UVAZ F7010UVLA F7010UVVD F7010UVVM F7015UVAM F7015NYAZ F7015UVLA F7015UVVD F7015UVVM F7023UVAM F7023NYAZ F7023NYLA F7023UVVD F7023UVVM F7028UVAM F7028UVAZ F7028UVVD F7028UVVM F7039UVAM F7039UVAZ F7039UVVD F7039UVVM F7040UVAM F7040UVAZ F7040UVVD F7040UVVM
yellow blue orange green red yellow blue orange green red yellow blue orange green red yellow blue green red yellow blue green red yellow blue green red
Ø Maximum Bundle
22
37
Minimum Tensile Strenght Kgf
lbs
N
8,2
18
80
13,6
30
135
51
76
22,7
50
225
F7015 F7023
14
Lenght X width (mm)
Complete Reference
Color
Ø Maximum Bundle
151 X 3,7 200 X 4,8 200 X 4,8
F7015NYAZ F7023NYAZ F7023NYLA
blue blue orange
Ø Maximum Bundle
82 X 2,3 108 X 2,5 209 X 2,5 151 X 3,7 202 X 3,7 125 X 4,8 200 X 4,8 238 X 4,8 283 X 4,8 400 X 4,8 300 X 7,6 398 X 7,6 535 X 8,8 765 X 8,8 1095 X 8,8 536 X 13,7
F7008HSPR F7010HSPR F7019HSPR F7015HSPR F7020HSPR F7012HSPR F7023HSPR F7024HSPR F7028HSPR F7039HSPR F7030HSPR F7040HSPR F7053HSPR F7076HSPR F70109HSPR F7054HSPR
16 22 55 37 51 28 51 60 76 114 80 110 147 220 330 147
Minimum Tensile Strenght Kgf
lbs
N
8,2
18
80
13,6
30
135
22,7
50
225
54,4
120
535
68
150
670
115
250
1115
Material: Nylon 4.6 Use temperature: -40 °C to 135 °C with peaks of 150 ºC Flammability: UL94 V2 This cable s line is produced from polyamide 4.6 and injection parameters for use in environments subjected to constant high temperature regimes.
54,4
120
535
Color Cable Ties without UV protection Group
Complete Reference
Abraçadeiras PA 4.6 para altas temperaturas
114
110
Lenght X width (mm)
Minimum Tensile Strenght Kgf
lbs
N
37
13,6
30
135
51
22,7
50
225
Lenght X width (mm)
Complete Reference
Color
Ø Maximum Bundle
108 X 2,5 209 X 2,5 151 X 3,7 202 X 3,7 125 X 4,8 200 X 4,8 238 X 4,8 283 X 4,8 400 X 4,8 300 X 7,6 398 X 7,6 535 X 8,8 765 X 8,8 1095 X 8,8 536 X 13,7
F7010NY4.6 F7019NY4.6 F7015NY4.6 F7020NY4.6 F7012NY4.6 F7023NY4.6 F7024NY4.6 F7028NY4.6 F7039NY4.6 F7030NY4.6 F7040NY4.6 F7053NY4.6 F7076NY4.6 F70109NY4.6 F7054NY4.6
black black black black black black black black black black black black black black black
22 55 37 51 28 51 60 76 114 80 110 147 220 330 147
Minimum Tensile Strenght Kgf
lbs
N
8,2
18
80
13,6
30
135
22,7
50
225
54,4
120
535
68
150
670
115
250
1115
15
Cable ties Accessories
Cable ties Accessories
Adhesive Fasteners These fasteners, when used with conventional cable ties, allow the cables, hoses and other components lashing without the need for drilling. Adhesives are of excellent quality and can be used indoors and outdoors. Before the application of the fastener, it is recommended to clean the surface with isopropyl alcohol so that it will stay clean, dry and uniform.When the surface is very smooth you may need to make a small abrasion. When using adhesive fasteners EA and EAA, you may need the primer from 3M reference 8215 P to improve the adherence in surfaces with epoxy paint.The PL adhesive fasteners do not require primer. Level of adherence
These are products that increase productivity and securing the efficiency of various components when used together with conventional cable ties.
20 min
1 hour
1 day
3 days
Application time
INTENSITY OF ADHERENCE
F7801
Adhesive EAA
F7802
F7803
Level of adherence Indoors
Outdoors
Epoxi paint
very good
very good
good
EA
great
great
good
PL
excellent
excellent
excellent
REF
Base color
F7801EAA F7802EAA F7803EAA F7801EA * F7802EA * F7802UVEA * F7802PL ** F7803PL **
natural natural / black natural natural natural / black natural with UV protection natural natural
Width of cable ties (mm) até 4,8 até 7,6 até 4,8 até 4,8 até 7,6
* Adhesive 3M ** 3M Primer Less adhesive
Items with EA adhesive have 34% more grip that items with EAA adhesive. Items with PL adhesive have 264% more grip that items with EAA adhesive.
16
17
Cable ties Accessories
Fasteners without adhesives
Bushing
These fasteners were developed for binding wires, cables and electrical harnesses in different surfaces by screws or rivets, with the use of a conventional cable tie.
This product speeds up the installation of wires, cables, hoses and pipes in concrete, solid brick or wood walls. The bushing is inserted into the hole with a hammer, preferably a rubber hammer, and does not require screw fixation. The bushing provides support for mooring by conventional cable ties. When the bushing is exposed to sunlight, it is recommended the use of cable ties with UV protection (page 13).
Material
Color
Operating Temperature
Flammability
Nylon 6.6 (PA 6.6)
Natural / black
-40ºC a 85ºC
UL94 V2
Nylon 6.6 UV (PA 6.6 UV)
White / black
-40ºC a 85ºC
UL94 V2
REF
Base (mm)
Height (mm)
Ø of hole (mm)
Type of cable ties
F7808 *
15 X 10
7
3,4
All models with a width of up 4,8 mm
Material
Color
Operating Temperature
Flammability
F7809 **
22 X 15
9,25
5,1
All models with a width of up 8,8 mm
FSA7802
28 X 28
6
6
All models with a width of up 4,8 mm
Nylon 6.6 UV (PA 6.6 UV)
Black
-40ºC a 85ºC
UL94 V2
* Can be applied with 6 mm screw/bushing and supports up to 32 kgf. * Can be applied with 6 to 8 mm screw/bushing and supports up to 50 kgf.
REF F7821
Plugs
A (mm) B (mm) C (mm) D (mm) 12,5
38,5
10
9,5
E (mm)
Ø of hole (mm)
Type of cable ties
2,5
Soft materials: 8 mm Hard materials: 9 mm Very hard materials: 9,5 mm
All models with a width of up 8,5 mm
FRONTEC also provides the bushing with the cable tie. Refer to item: “Bushing with cable tie”, page 27.
This fastener model is designed to be used with a conventional cable tie with width up to 4.8 mm.It has the body formed by parallel blades, which increases the fixing quality and performance, as they require low to high power for placement and extraction.It is very easy for tying electrical harnesses and other components to plates (flat hole) or steel blocks (threaded hole).
Clip for plates attachment This clip used with a conventional cable tie, allows a quick, easy and economic attachment in plates, of wires and cables. Without using screws or rivets.
C
A B
Color
Operating Temperature
Flammability
Nylon 6.6 HS (PA 6.6 HS)
Black
-40ºC a 105ºC
UL94 V2
REF
A (mm)
B (mm)
C (mm)
Ø of hole (mm)
Sheet thickness
Type of cable ties
FP6L
16
5
10,7
6,5 a 7 or thereaded hole M8
0,8 a 6 mm
With a width of up to 4,8 mm
FP7
16
5
12,7
6,5 a 7 or thereaded hole M8
0,8 a 7 mm
With a width of up to 4,8 mm
FP8
16
5
11,1
7,7 a 8 or thereaded hole M10
0,8 a 6 mm
With a width of up to 4,8 mm
FRONTEC also offers the plugs with cable ties already placed. Refer to item: “Plug assembled with cable tie (FP)”, page 22.
18
C
Material
A
D
B
Drawing
Material
Color
Operating Temperature
Flammability
Nylon 6.6 (PA 6.6 )
Natural / black
-40ºC a 85ºC
UL94 V2
REF F7830
A (mm) B (mm) C (mm) D (mm) 9,5
16,6
7,5
3,3
Ø of hole (mm)
Sheet thickness
Type of cable ties
6,4
Max 3 mm
All models with a width of up 3,7 mm
19
Special Cable ties
Clip for attachment in rectangular cutouts This fastener has a socket to attach relays, and a hole for the insertion of conventional cable ties with width up to 4.8 mm.
Material
Color
Operating Temperature
Flammability
Polyacetal (impact modified)
Black
-40ºC a 100ºC
UL94 HB
REF
Furo (mm)
Sheet thickness
Maximum insertion force
Minimum extraction force
FC8X15
8,0 X 15,0
0,7 a 2,1 mm
5,0 kgf
70,0 kgf
These cable ties are used in the automotive industry because they increase performance and quality of different binding processes, making them safer and economic.
Bracket for two bindings Material: PA 6.6 Operating Temperature: 40°C to 85°C Flammability: UL94 V2 This piece allows the use of two parallel cable ties to secure and separate two bindings. The clamps can rotate at an angle of up to 90° differently from one another. Very useful for separating hoses and avoiding friction wear.
Ref: FSUP
20
Ref
Height (mm)
Diameter (mm)
Color
Type of cable ties
FSUP
8,1
12
Black
Até 4,8 mm
21
Special Cable ties
Cable ties for threaded pin binding
Cable ties with fixing plug
This clamp is designed for binding electrical harnesses or other components directly on screws or threaded pins.
head
The FRONTEC manufactures a range of cable ties with fixing plug already in the part. The plug is built with a technology that enables the use of the product with low insertion force and high extraction force, enabling quality and performance in the binding of electrical harnesses or other components.
body
Material
Color
Operating Temperature
Flammability
Nylon 6.6 HS (PA 6.6 HS) Nylon HS IM (PA 6.6 HS IM)
Natural / black Black
-40ºC a 105ºC -40ºC a 105ºC
UL94 V2 UL94 V2
REF FM56 8023 FM8 8023
Lenght (mm) Body
Head
187 187
25,4 25,9
Width (mm)
Ø máx of lashing (mm)
6,20 6,20
51 51
Minimum Tensile Strenght Kgf
Lbs
N
Threaded pin binding
22,7 22,7
50 50
225 225
M5 ou M6 M8
Plug assembled with cable tie (FP)
Material
Color
Operating Temperature
Nylon 6.6 HS (PA 6.6 HS)
Natural / black
-40ºC a 105ºC
UL94 V2
Nylon HS IM (PA 6.6 HS IM)
Black
-40ºC a 105ºC
UL94 V2
This product is used with cable ties width up to 4.8 mm for binding electrical harnesses or other components. The fixing blades have a design that enhances the quality and performance of the binding, it has low insertion force and high extraction force.
plug
Flammability
body
Ordinary Knurled REF
Produto Cable tie Plug
REF FP6L 7010 FP6L 7015 FP6L 7023 FP7 7010 FP7 7015 FP7 7023
22
Material
Color
Operating Temperature
Flammability
Nylon 6.6 (PA 6.6) Nylon 6.6 HS (PA 6.6 HS) Nylon 6.6 HS (PA 6.6 HS)
Natural / black Natural / black Black
-40ºC a 85ºC -40ºC a 105ºC -40ºC a 105ºC
UL94 V2 UL94 V2 UL94 V2
Cable tie
Plug
Lenght (mm)
Width (mm)
108 151 200 108 151 200
2,5 3,7 4,8 2,5 3,7 4,8
Minimum tensile Strenght
Height (mm)
Ø máx of lashing (mm)
Kgf
Lbs
N
10,7 10,7 10,7 12,7 12,7 12,7
22 37 51 22 37 51
8,2 13,6 22,7 8,2 13,6 22,7
18 30 50 18 30 50
80 135 225 80 135 225
Plate hole diameter (mm)
Plate thickness (mm)
6,5 a 7 or threaded hole M8 6,5 a 7 or threaded hole M8 6,5 a 7 or threaded hole M8 6,5 a 7 or threaded hole M8 6,5 a 7 or threaded hole M8 6,5 a 7 or threaded hole M8
0,8 a 6 0,8 a 6 0,8 a 6 0,8 a 7 0,8 a 7 0,8 a 7
FP8 7015
151
3,7
11,1
37
13,6
30
135
7,7 a 8 or threaded hole M10
0,8 a 6
FP8 7023
200
4,8
11,1
51
22,7
50
225
7,7 a 8 or threaded hole M10
0,8 a 6
Plug
Lenght (mm)
Minimum tensile Strenght
Width (mm)
Ø máx of lashing (mm)
Kgf
Lbs
N
Plate hole
Plate thickness (mm)
Body
Plug
F5 8023
198
7
4,8
51
22,7
50
225
Ø 5 mm or threaded hole M6
0,7 a 3
F6 8023
198
9,3
4,8
51
22,7
50
225
Ø 6,3 a 7 mm or threaded hole M8
0,7 a 2,5
F6L 8023
198
15
4,8
51
22,7
50
225
Ø 6,3 a 7 mm or threaded hole M8
0,7 a 7
F8 8023
198
17,5
4,8
51
22,7
50
225
Ø 8 ± 0,25 mm or threaded hole M10
0,7 a 7
FOB 8023
198
11,1
4,8
51
22,7
50
225
6,2 x 12,2 mm
0,7 a 6
9,3
4,8
51
22,7
50
225
Ø 6,3 a 7 mm or threaded hole M8
0,7 a 2,5
Plug
Reverse knurled F6I 8023
198
23
Special Cable ties
Cable ties with plug
Cable tie with eye
This clamp has the fixing plug away from the head. It is very useful when the tying have to get a little displaced from the hole where the plug is.
plug
This cable tie model is useful for cable, hoses and other components fixing by screws and rivets.
body
Material
Color
Operating Temperature
Flammability
Nylon HS (PA 6.6 HS)
Natural / black
-40°C a 105°C
UL94 V2
Lenght (mm)
REF FT58023
Body
Plug
200
25,4
Minimum tensile Strenght
Width (mm)
Ø máx of lashing (mm)
Kgf
Lbs
N
6,2
45
22,7
50
225
eye bolt
Plate hole
Plate thickness (mm)
ø 5mm or threaded hole M6
0,7 a 3,5
Cable tie with fixing clip These cable ties have a fixing clip in arrow shape and are widely used for the attachment harness or hoses in metal plates.
body
Material
Color
Operating Temperature
Flammability
Nylon HS (PA 6.6 HS)
Natural / black
-40ºC a 105ºC
UL94 V2
Lenght (mm)
REF FO8023
Eye bolt
Body
12,5
187,5
Width (mm)
Ø máx of lashing (mm)
Ø of hole (mm)
4,8
45
5,2
Minimum Tensile Strenght Kgf
Lbs
N
22,7
50
225
Cable ties with double head Appropriate for fixing two whips or components using two loops.
Material
Color
Operating Temperature
Flammability UL94 V2
Nylon 6.6 (PA 6.6)
Natural / black
-40ºC a 85ºC
Nylon HS (PA 6.6 HS)
Black
-40ºC a 105ºC
UL94 V2
Nylon 6.6 V0 (PA V0)
White
-40ºC a 85ºC
UL94 V0
clip
REF
24
Lenght (mm)
body
Minimum tensile Strenght
Width (mm)
Ø máx of lashing (mm)
Kgf
Lbs
N
Plate hole diameter (mm)
Plate thickness (mm)
Clip
Body
FC7010
5,5
100
2,5
19
8
18
80
4,75 ± 0,1
3 máx
FC7013
8,5
135
4,8
24
22,7
50
225
6,3 ± 0,2
0,8 a 2,7
FC7014
8,5
135
4,8
24
22,7
50
225
4,7 ± 0,1
3,2 a 4
Clip
Material
Color
Operating Temperature
Flammability
Nylon 6.6 (PA 6.6)
Natural
-40ºC a 85ºC
UL94 V2
REF
Lenght (mm)
Width (mm)
FCD7023
195
4,8
Ø máx of lashing (mm) a: 47
b: 45
Ø mín of lashing (mm) a: 2,5
b: 2
Minimum Tensile Strenght Kgf
Lbs
N
22,2
49
218
25
Special Cable ties
Cable tie with clip and central fixing
Bushing with Cable tie
Material: PA 6.6 Operating Temperature: 40°C to 85°C Flammability: UL94 V2
This product facilitates the attachment of wires, cables and tubes in concrete, brick and wood walls. The bushing provides support for mooring by conventional cable ties.
This clamp allows the fixation of cables, hoses and other components centrally, regardless of its diameter. It has claws on part of the belt to prevent the volume slip tied in the cable tie strap and the side flaps that keep the clip pressed in the drilling.
REF
Measures of cable tie
Lenght of clip
Ø of plate hole
Plate thickness
Ø máx of lashing
FCT8023
209 X 4,7 mm
6,4 mm
6,4 ± 0,1 mm
0,6 a 3,0 mm
50 mm
Cable ties reutilizáveis
Material
Color
Operating Temperature
Flammability
Nylon 6.6 UV (PA 6.6 UV)
Black
-40°C a 85°C
UL94 V2
Ø máx of lashing (mm)
Ø of hole (mm)
Minimum Tensile Strenght
110
8 for soft materials 9 ou 9,5 for hard materials
REF
These pieces have a latch that allows its reuse. Suitable for organizing telephone and logic networks.
FB7040
Lenght (mm)
Width (mm)
398
7,6
Kgf
Lbs
N
54,4
120
535
Seal with limiter This product was developed to improve tracking systems, where the use of plastic or paper labels is necessary, and has the following characteristics:
Material
Color
Operating Temperature
Flammability
Nylon 6.6 (PA 6.6)
Natural
-40ºC a 85ºC
UL94 V2
Minimum Tensile Strenght
REF
Lenght (mm)
Width (mm)
Ø máx of lashing (mm)
FRE7015 FRE7025
150 250
7,6 7,6
35 66
Kgf
Lbs
N
22,2 22,2
48 48
217 217
• Basis for sequential recording of up to 11 digits; • Sealing function; • Limiter to avoid damaging the label.
Cable tie for chassis This piece is widely used for the attachment of harness and hoses along bus and trucks chassis. The tape of the cable tie connects the harness or the component to be fixed and goes to the head of the part where it gives the lock (on the other side of the chassis).
A
D
C
B
26
Material
Color
Operating Temperature
Flammability
Nylon 6.6
Black
-40ºC a 85ºC
UL94 V2
REF
Lenght (mm)
Width (mm)
Ø máx of lashing (mm)
Ø of hole (mm)
F7300
300
6
80
7 a 12
Minimum Tensile Strenght Kgf
Lbs
N
18
40
180
Material
Color
Operating Temperature
Flammability
Nylon 6.6 HS (PA 6.6 HS)
Natural / black
-40ºC a 105ºC
UL94 V2
Nylon 6.6 (PA 6.6)
Natural, black and colors
-40ºC a 85ºC
ULV4 V2
REF
A (mm)
B (mm)
C (mm)
D (mm)
Ø máx of lashing (mm)
FL7027
280
32,2
5,2
13
39
Minimum Tensile Strenght Kgf
Lbs
N
13,6
30
135
Number engraving only.
27
Stainless Steel Cable ties
Identification Cable ties These cable ties have a basis for engraving identification or labeling.
Material
Color
Operating Temperature
Flammability
Nylon 6.6 (PA 6.6)
Natural
-40°C a 85°C
UL94 V2
REF
Lenght (mm)
Width (mm)
Marker (mm)
We manufacture the most complete line of stainless steel cable ties with locking system by lock and ball. We can also deliver cable ties in the most appropriate length for each project.
Minimum Tensile Strenght
Ø máx of lashing (mm)
Kgf
Lbs
N
FMTI7010
100
2,5
25,4 X 8
18
8,2
18
80
FMTE7010
112
2,5
20,4 X 9,1
18
8,2
18
80
FMHI7023
190
4,8
13 X 28
46
22,2
49
218
FMHI7039
370
4,8
13 X 28
102
22,2
49
218
Tools for polyamide cable ties A12001-0 (professional)
A12500-0 (professional)
Manual tool by Avery Dennison company. Use: cable ties with width of up to 4.8 mm
Pneumatic tool by Avery Dennison company. Use: cable ties with width of up to 4.8 mm
Width of cable tie (mm)
Level of strenght
2,5 3,7
2 2
4,8
3
F8005
F8006
Manual tool. Use: cable ties with width of up to 4.8 mm
28
Manual tool. Use: tools with width of 7.9 mm or 8.8 mm
widht of cable tie (mm)
Level of strenght
widht of cable tie (mm)
Level of strenght
2,5
1
7,6
2
3,7
1
8,8
3
4,8
6
29
Stainless Steel Cable ties
Stainless Steel Cable ties without coating
Polyester Coated Stainless Steel Cable Ties
FRONTEC stainless steel cable ties were created to be used in severe environment and conditions and present the following characteristics: • High mechanic and chemicals resistance; • Allow the fixation of the most different materials and objects; • Does not loosen with vibrations; • May be used in cases of extreme temperature and in highly corrosive environments;
Material
We produce any size perfect for your project “just in time”
REF
30
Lenght (mm)
• Present high strength and hardness in the loops; • Are installed with easy and have rounded corners that do not hurt the operator or the components being affixed.
Operating Temperature
Stainless steel AISI 316
Width (mm)
Ø máx of lashing (mm)
Minimum Tensile Strenght Lbs
N
• Are installed very easily; • Are fully covered, avoiding chemical battery.
• Do not hurt the operator and fixed components; • Good UV resistance; • AISI 316 Steel;
We produce any size perfect for your project “just in time”
-80ºC a 538ºC
Kgf
Polyester coated stainless steel cable ties are specially indicated for naval application when are tied with materials with distinctive chemical characteristics. They have high resistance to corrosion and weathering.
Material
Operating Temperature
Stainless steel AISI 316 with coated strip with polyester
-40ºC a 150ºC
REF
Lenght (mm)
Width (mm)
Ø máx of lashing (mm)
FA0127
127
4,6
25
FARP 0127
127
4,6
25
FA0201
201
4,6
50
FARP 0201
201
4,6
50
FA0259
259
4,6
69
FARP 0259
259
4,6
69
FA0362
362
4,6
102
FARP 0362
362
4,6
102
FA0521
521
4,6
152
FA0681
681
4,6
203
FARP 0521
521
4,6
152
FARP 0681
681
4,6
203
FA0838
838
4,6
FA0998
998
4,6
254
FARP 0838
838
4,6
254
304
FARP 0998
998
4,6
304
FA1156
1156
4,6
FA1205
1205
4,6
355
FARP 1156
1156
4,6
355
370
FARP 1205
1205
4,6
370
FAL0201
201
7,9
FAL0259
259
7,9
50
FALRP 0201
201
7,9
50
69
FALRP 0259
259
7,9
FAL0362
362
69
7,9
102
FALRP 0362
362
7,9
102
FAL0521 FAL0681
521
7,9
152
FALRP 0521
521
7,9
152
681
7,9
203
FALRP 0681
681
7,9
203
FAL0838
838
7,9
254
FALRP 0838
838
7,9
254
FAL0998
998
7,9
304
FALRP 0998
998
7,9
304
FAL1156
1156
7,9
355
FALRP 1156
1156
7,9
355
FAL1205
1205
7,9
370
FALRP 1205
1205
7,9
370
FALL0434
434
12,7
122
FALLRP 0434
434
12,7
122
FALL0594
594
12,7
173
FALLRP 0594
594
12,7
173
FALL0754
754
12,7
224
FALLRP 0754
754
12,7
224
FALL0912
912
12,7
275
FALLRP 0912
912
12,7
275
FALL1072
1072
12,7
325
FALLRP 1072
1072
12,7
325
FALL1205
1205
12,7
370
FALLRP 1205
1205
12,7
370
100
225
300
220
496
661
980
2206
2942
Minimum Tensile Strenght Kgf
Lbs
N
100
220
980
225
496
2206
300
661
2946
31
Stainless Steel Cable ties
Protecting tape for Stainless Steel Cable ties
Stainless Steel Cable ties in coil
The use of stainless steel cable ties with protective tape give the tying:
This product is suitable for applications where it is not possible to determine in advance the required lengths. The tape and the lock are produced in stainless steel AISI 316 and packaged to facilitate their storage and use.
• Separation of metals with different characteristics avoiding chemical battery; • Absorption of small return, characteristic of the type of closure by ball used, eliminating the slack in the tying point; • Protection of the edges of the cable tie.
Uncovered
Material
Color
Operating Temperature
Flammability
Flame retardant Polyethylene with UV
Black
-40ºC a 90ºC
Flame retardant classification UL94-V0
REF
Width (mm)
A (±0,3)
B (±0,3)
C (±0,3)
D
Package
FITA4,6PE
4,6
3,2
6,5
1,4
9,3
25 m
FITA7,9PE
7,9
3,7
10,5
1,4
13,3
25 m
FITA12,7PE
12,7
4,7
16,7
1,4
19,5
25 m
REF
Width (mm)
Lenght of the strip in the box (m)
Minimum Tensile Strenght Kgf
Lbs
N
FA4,6FITA
4,6
50
100
220
980
FAL7,9FITA
7,9
50
225
496
2206
FALL12,7FITA
12,7
50
300
661
2946
With polyester cover Minimum Tensile Strenght
REF
Width (mm)
Comprimento da fita na caixa (m)
Kgf
Lbs
N
FARP4,6FITA
4,6
50
100
220
980
FALRP7,9FITA
7,9
50
225
496
2206
FALLRP12,7FITA
12,7
50
300
661
2946
Lock
Stainless steel clamps with double loop uncoated The body of the clamp passes twice through the head providing a significant increase in minimum tensile strength.
REF
Lock for strip - width (mm)
Quantity per box (pieces)
FARP4,6FITA
4,6
100
FALRP7,9FITA
7,9
100
FALLRP12,7FITA
12,7
100
Stainless steel markers - Already Engraved Used to identify cables and pipes in harsh environments such as oil rigs, ships, petrochemical industry, shipbuilding, steel works, railways, subways, mines, among others. Design with lowered holes to facilitate passage of the cable tie.
32
Material
Operating Temperature
Stainless Steel AISI 316
-80ºC a 538ºC
Ø máx of lashing (mm)
REF
Lenght (mm)
Width (mm)
FALD20470
470
7,9
51
FALD20711
711
7,9
102
FALD20863
863
7,9
127
FALD21016
1016
7,9
152
FALLD20749
749
12,7
102
FALLD21054
1054
12,7
152
FALLD21359
1359
12,7
203
Minimum Tensile Strenght Kgf
Lbs
N
272
600
2670
363
800
3560
Material
Operating Temperature
Stainless Steel AISI 316
-80ºC a 538ºC
REF
Lenght (mm)
Width (mm)
Type of cable tie
FAIG10X90
90
10
With width up to 7,9 mm
Number of characters Up to 18 characters
FAIG20X90
90
20
With width up to 7,9 mm
Up to 32 characters (2 lines with 16 each)
33
Tools for Stainless Steel Cable ties
F8003 Manual tool. Enforcement Cable ties with a width of up to 7.9 mm. It has a button to adjust the voltage according to the width of the cable tie. The use allows the constant tensioning and cutting of the cable tie close to the head.
Fasteners These products allow the attachment of various components in a fast, safe, economical and durable way.
F8001 Manual tool. Enforcement Cable tie with width up to 12.7 mm. The cutting is done by moving the cable tie of the lever.
F8004 Hand tool for finishing of stainless steel cable tie. Enforcement Cable ties with a width of up to 12.7 mm.
34
35
Fasteners
Adhesive Clip
Tree Clip
This product is suitable for the attachment of hoses and cables with diameter of approximately 13 mm.
This clip is an excellent product for fixing trim panels in the automotive and furniture industry.
Level of adherence
20 min
1 hour
1 day
3 days
C
Application time B
Two types of adhesives, EA and EAA are provided, both of which have high quality and can be used on internal and external environments. Before applying the clip it is recommended that the surface is cleaned with isopropyl alcohol.
A
Material
Color
Operating Temperature
Flammability
Nylon 6.6 (PA 6.6)
Grey and Black
-40ºC a 85ºC
UL94 V2
*Outras Colores sob consulta.
REF
Measures (mm)
Ø of clip (mm)
F7813EAA
23,5 X 24
13
F7813EA *
23,5 X 24
13
REF
A (mm)
B (mm)
C (mm)
Ø of hole (mm)
F7822
7,8
33,7
20
6,8 a 7,2
*3M adhesive
Directing plugs
Plug for finishing
This product consists of a plug and a cable duct where the electrical harness can be placed. The plug has the form of several parallel fins that make the insertion quick and very efficient.
This piece allows the attachment of two surfaces, one by the plug and the other by the head piece. It is used to attach the part with foam of benches at its base, for example, bus seats benches.
A
B
C
B
A
36
Material
Color
Operating Temperature
Flammability
Nylon 6.6 HS (PA 6.6 HS)
Black
-40ºC a 105ºC
UL94 V2
Material
Color
Operating Temperature
Flammability
Nylon 6.6 (PA 6.6 )
Cinza e Black
-40ºC a 85ºC
UL94 V2
*Outras Colores sob consulta.
REF
A (mm)
B (mm)
C (mm)
Plate hole diameter (mm)
Plate thickness (mm)
REF
A (mm)
B (mm)
Ø of hole (mm)
Plate thickness (mm)
F1291
36,3
11,1
9,7
6,5 a 6,7
0,6 a 5,1
F7823
14,7
13
8
3,5
37
Fasteners
Alligator Cable ties
Cable fasteners
This cable tie has two sets of teeth that fit into one another when they are tightened together. It is very useful for joining two plastic hoses.
They are very useful products for the attachment of harnesses, pipes of oil and gas and other items. With few items you can make bindings with various diameters.
Material
Color
Operating Temperature
Flammability
NYLON 66 (PA 66) com fibra de vidro
Black
-40ºC a 148ºC
UL94 V2
REF
Thickness (mm)
Width (mm)
Ø mín of lashing (mm)
Ø máx of lashing (mm)
FJ7718
1,8
6
19,8
22,8
Material
Color
Operating Temperature
Flammability
Nylon 6.6 (PA 6.6 )
Natural e Black
-40ºC a 85ºC
UL94 V2
REF
Ø of cable (mm)
Width (mm)
Lenght (mm)
F7901 F7902 F7903 F7904 F7906 FR7908 FR7911 FR7914 FR7916 FR7918
4,8 6 8 10,3 14,5 12,7 a 15,9 15,9 a 20,6 20,6 a 25,4 27 a 31,8 33,3 a 38,1
9,5 11 11 12,3 12,3 12,9 12,7 15,9 19,2 19,1
18,1 21,8 22,5 26,2 30,3 31 36 48,2 56,4 63
The FR items have setting that enable fixing cables and hoses of various diameters.
Self-locking clip
Candle cable fasteners
Fixation of the hose from the hydraulic system of Fiat cars.
Enforcement: Fixation of the GM car spark plug wires.
FGM4
Material Nylon 6.6 (PA 6.6)
38
Color
Operating Temperature
Black
-40°C a 85°C
FGM3
FGM2
FCGM2
Material
Color
Operating Temperature
Flammability
Nylon 6.6 HS (PA 6.6 HS)
Black
-40ºC a 105ºC
UL94 V2
Flammability
REF
Ways
Plate thickness (mm)
Fixing rips (mm)
Ø of hole (mm)
UL94 V2
FGM2
2
1,3 a 1,7
6,4 a 8
5a7
FGM3
3
1,3 a 1,7
6,4 a 8
5a7
4
1,3 a 1,7
6,4 a 8
5a7
2
REF
Plate thickness (mm)
Ø máx for accommodation (mm)
FGM4
FCA12
0,5 a 1,3
12
FCGM2
5a7
39
Cable Organizers
Cable Organizers
Spiral tube FRONTEC spiral tubes have flexibility, wall thickness and cutting standard that provide its fast and easy handling. It is an excellent product for tying and accommodation of harnesses, allowing the derivation at any point of it.
grey
orange
white
yellow
black
clear
Material
Color
Operating Temperature
Flammability UL94 HB
Polyethylene
White, black, grey and colors
-40ºC a 80ºC
Polyethylene AC (chame retardant) *
Grey
-40ºC a 80ºC
UL94 V0
Polyethylene UV (ultraviolet protection) *
Black
-40ºC a 80ºC
UL94 HB
Teflon (antichamas) *
Clear
-80ºC a 260ºC
UL94 V0
*Produzidos sob encomenda.
40
REF
Ø external (pol)
Ø external (mm)
Ø máx of lashing (mm)
Package
F7118 F7114 F7138 F7112 F7158 F7134 F 7101
1/8 1/4 3/8 1/2 5/8 3/4 1
4,8 6,5 9,5 11,2 15,9 18 23
3,2 a 12,5 5 a 50 8 a 80 9,5 a 101 11,5 a 105 17 a 150 23 a 200
50 m 5m 1m
41
Self-fixable Cable ties Recoverable tying system, especially developed for applications such as: optical fiber cables, computer networks, product identification etc. Ideal for temporary applications in which a constant opening is required. Very simple usage, as it does not use any kind of tool. L
Heat Shrinkables
C
They are tubes produced with reticulated polyolefin pipe which shrink when subjected to heat, causing electrical isolation.
REF
Lenght C (mm)
Width L (mm)
Package
FVGT 150
150
12
5 pieces
FVGT 200
200
12
5 pieces
Wire markers Wire markers are ideal for identifying wires and cables. The angled cut enables the maintenance of the set alignment and its design enables a single marker model to be used in various gauges of wires or cables.
Material
Color
Print
PVC Flexible
Yellow printed in black
Letters A - Z Numbers 0 - 9 Symbols + - \ /
42
REF
Cable size
Metric series (mm2)
Amount of pieces per package
FGT 0
18 AWG - 12 AWG
0,75 - 2,5
100
FGT 1
18 AWG - 10 AWG
0,75 - 4
100
FGT 2
12 AWG - 8 AWG
2,5 - 6
100
FGT 3
8 AWG - 6 AWG
6 - 10
50
43
Heat Shrinkables
Shrink Tubes with low voltage (1 kV) Standard wall - Shrink 2:1
Shrink Tubes with low voltage (1 kV) Adhesive - Shrink 3:1
• Meets RoHS and Sony standard • Material = flexible polyolefin • Use temperature = -55 ºC a 125 ºC • Shrink Temperature = starts at 70 °C and ends at 120 °C • Flammability = UL VW-1 • Longitudinal shrinkage of less than 8% • Supplied in coils Chemical element Cd Pb Cr6+ Hg F Cl Br I
Test method (mm) EN1122:2001 Method B EPA 3050 B EPA 3050 B EPA 3052 EN 14582 Method B EN 14582 Method B EN 14582 Method B EN 14582 Method B
Result (mg/kg)
Tensile strenght (Mpa) Elongation
≤5 ≤ 90 ≤5 ≤5 ≤ 200 ≤ 800 ≤ 800 ≤ 200
Physical
Chemical
REF
(mm)
(pol)
1 1,5 2 2,5 3 3,5 4 4,5 5 6 7 8 9 10 13 16 17 18 20 22 25 28 30 35 40 45 50 60 70 80 90 100 120 150 180
3/64 1/16 3/32 3/32 1/8
W1,0 W1,5 W2 W2,5 W3,0 W3,5 W4 W4,5 * W5 W6 W7 W8 W9 W10 W13 W16 W17 W18 W20 W22 W25 W28 W30 W35 W40 W45 W50 W60 W70 W80 W90 W100 W120 W150 W180
3/16 3/16 1/4 1/4 5/16 3/8 1/2 5/8 5/8 3/4 3/4 1 1-1/4 1-1/2 2 3 4 5
Tensile strenght after aging (Mpa) Elongation after aging (%)
Thermal shock - coldest
d
Internal Ø after max. recovery (d) (mm)
Wall thickness after máx. recovery (W) (mm)
0,65 0,85 1 1,3 1,5 1,8 2 2,3 2,5 3 3,5 4 4,5 5 6,5 8 8,5 9 10 11 12,5 14 15 17,5 20 22,5 25 30 36 40 46 51 60 75 90
0,28 0,32 0,35 0,38 0,4 0,42 0,45 0,5 0,55 0,55 0,55 0,6 0,6 0,6 0,65 0,7 0,7 0,8 0,8 0,8 0,9 0,9 0,95 1 1 1 1 1,3 1,3 1,46 1,46 1,46 1,56 1,56 1,56
Dieletric voltage (kV/mm) 300 V Dielectric strenght 600 V Volume resistivity (Ω.cm) Copper corrosion Cooper stability Flammability
Equivalent range Ø (mm)
Result ≥ 10,4 ≥ 200
ASTM D2671
Thermal shock - heat
W
Internal Ø expanded (D)
Test method
Property
Eletrical D
The adhesive shrink tubes are semi-flexible and contains internal coating of thermoplastic adhesive, providing complete protection against moisture. Are indicated for use in cable ends, wire taps, connectors, splices of electric and telephone wires, among other applications.
UL 224 158ºC X 168 hrs UL 224 158ºC X 168 hrs UL 224 250ºC X 4 hrs UL 224 -30ºC X 1 hr IEC 243 UL 224
≥ 100
NO cracking ≥ 15 Not changed to 1500 V Not changed to 2500 V
UL 224 158ºC / 168 hrs
Pass Pass VW - 1
UL 224
Máx
0,72 0,94 1,1 1,43 1,65 1,98 2,2 2,53 2,75 3,3 3,85 4,4 4,95 5,5 7,15 8,8 9,35 9,9 11 12,1 13,75 15,4 16,5 19,25 22 24,75 27,5 34,1 39,6 45,1 50,6 56,1 67,1 83,6 100,1
1,2 1,6 2 2,4 2,8 3,2 3,6 4 4,4 5,2 6 6,8 7,6 8,4 10,8 13,6 14,4 15,2 17,6 19,2 20,8 23,2 25,2 29,2 33,2 36,8 40,8 48 56 64 72 80 96 120 144
2,36 3,14 3,93 4,71 5,5 6,28 7,07 7,85 8,64 10,21 11,78 13,35 14,92 16,49 21,21 26,7 28,26 29,84 34,56 37,7 40,84 45,55 49,48 57,33 65,19 72,25 80,11 94,25 109,95 125,66 141,37 157,08 188,49 235,61 282,74
Expanded Perímeter (mm)
M / Spool
4,71 6,28 7,85 9,42 10,99 12,56 14,13 15,7 17,27 20,41 23,55 26,69 29,83 32,97 42,39 53,38 56,52 59,66 69,08 75,36 81,64 91,06 98,91 114,61 130,31 144,44 160,14 188,4 219,8 251,2 282,6 314 376,8 471 565,2
200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 25 25 25 25 25 25 25 25 25 25
The measures highlighted in gray are only available in black. Colors: black
44
white
red
yellow
green
purple
blue
gray
d
NO dripping NO cracking
≥ 1 X 1014
Mín.
W D
≥ 7,3
IEC 93
Width of the flattened tube (mm)
• Use temperature = -45 ºC a 125 ºC • Shrink Temperature = starts at 70 °C and ends at 120 °C • Material = flexible polyolefin with internal adhesive “hot melt” • Longitudinal shrinkage = of less than 8% • Waterproof • Supplied in coils • Adhesive melting temperature 70°C to 90°C
brown
clear
Chemical element
Test method (mm)
Result (mg/kg)
Cd Pb Cr6+ Hg F Cl Br I
EN1122:2001 Method B EPA 3050 B EPA 3050 B EPA 3052 EN 14582 Method B EN 14582 Method B EN 14582 Method B EN 14582 Method B
≤5 ≤ 90 ≤5 ≤5 ≤ 200 ≤ 800 ≤ 800 ≤ 200
REF WA1/8 WA 3/16 WA1/4 WA5/16 WA3/8 WA1/2 WA5/8 WA3/4 WA1 WA1-1/4 WA1-1/2 WA2
Internal Ø expanded (D) (mm)
(pol)
Internal Ø after max. recovery (d) (mm)
3,2 4,8 6,4 7,9 9,5 12,7 15 19,1 25,4 30 40 50
1/8 3/16 1/4 5/16 3/8 1/2 5/8 3/4 1 1-1/4 1-1/2 2
1 1,6 2,2 2,7 3,2 4,2 5,2 6,3 8,5 10,2 13,5 17
TUBE Test method
Result
ASTM D2671 ASTM D2671
≥ 12 ≥ 300
UL 224 158ºC X 168 hrs
≥ 7,3
UL 224 158ºC X 168 hrs
≥ 200
IEC 243
≥ 15
IEC 93
≥ 1 X 1014
Property
ADHESIVE Test method
Result
Water absorption Softening point
ASTM D570 ASTM E28
≤ 0,2% 95ºC
Property Tensile strenght (Mpa) Elongation (%) Tensile strenght after aging (Mpa) Elongation after aging (%) Dieletric voltage (kV/mm) Volume resistivity (Ω.cm)
Wall thickness after máx. recovery (W)* (mm) 0,95 1,1 1,2 1,35 1,45 1,7 1,8 2 2,1 2,2 2,4 2,8
Equivalent range Ø (mm) Mín.
Máx
width of the flattened tube (L) (mm)
1,1 1,76 2,42 2,97 3,52 4,62 5,72 6,94 9,36 11,23 14,86 14,85
2,56 3,84 5,12 6,32 7,6 10,16 12 15,28 20,32 24 32 32
5,03 7,54 10,05 12,41 14,92 19,95 23,56 30 39,9 47,12 62,83 78,5
Expanded Perímeter (P) (mm)
M / Spool
10,05 15,07 20,1 24,81 29,83 39,88 47,1 59,97 79,76 94,20 125,6 157
200 100 100 100 50 25 25 25 25 25 25 25
See available colors.
45
Heat Shrinkables
Shrink Tubes with low voltage (1 kV) Green-yellow- Shrink 2:1
Shrink tubes for medium voltage • Tracking high resistance • Material = flexible polyolefin • Use temperature = -55 ºC to 125 ºC • Shrink Temperature = starts at 90 °C • Provided in black and red
• Meets RoHS standard • Material = flexible polyolefin • Use temperature = -55 ºC a 125 ºC • Shrink Temperature = starts at 70 °C and ends at 120 °C • Flammability = UL VW-1 • Longitudinal shrinkage of less than 8%
W D
Internal Ø expanded (D) REF (10 kV) (mm) (pol)
Property
Test method
Result
Tensile strenght (Mpa) Elongation (%) Tensile strenght after aging (Mpa) Elongation after aging (%)
ASTM D2671 ASTM D2671
≥ 10,4 ≥ 200
UL 224 158ºC X 168 hrs
≥ 7,3
Thermal shock - heat
UL 224 250ºC X 4 hrs
Dieletric voltage (kV/mm) Volume resistivity (Ω.cm) Flammability
IEC 243 IEC 93
≥ 1 X 1014
UL 224
VW-1
Ø interno expandido
Internal Ø after max. recovery (d) (mm)
Wall thickness after máx. recovery (W) (mm)
(mm)
(pol)
20
Internal Ø after max. recovery (d) (mm)
Wall thickness after máx. recovery (W) (mm)
9
3/4
30
Result Insulation up 42 kV 75 kV ≥ 25
Equivalent range Ø (mm)
≥ 4,3 X 1014
Mín.
Máx
Width of the flattened tube (mm)
Expanded Perímeter (mm)
M / Spool
2
9,91
16
31,4
62,8
25
13
2
14,31
24
49,48
94,2
25
50
2
20
2,5
22,02
40
80,11
157
25
80
3
32
3
35,23
64
125,66
251,2
25
100
4
40
3
44,03
80
157,08
314
25
120
5
48
3
52,84
96
188,49
376,8
25
70
3
77,06
144
282,74
565,2
25
180
≥ 100 NO dripping NO cracking ≥ 15
REF
46
UL 224 158ºC X 168 hrs
WB20-10kV WB30-10kV WB50-10kV WB80-10kV WB100-10kV WB120-10kV WB180-10kV
d
Property Tension (A.C.) Peak voltage TDieletric voltage (kV/mm) Volume resistivity (Ω.cm)
Shrinkers hood Equivalent range Ø (mm) Mín.
Máx
The Shrink hoods are given for the closure and isolation of power and communication in the cable ends, preventing chemical corrosion, moisture and dirt. width of the flattened tube (mm)
Expanded Perímeter (mm)
M / Spool
W1,5VA
1,5
1/16
0,85
0,32
0,94
1,6
3,14
6,28
200
W2,5VA
2,5
3/32
1,3
0,38
1,43
2,4
4,71
9,42
200
W3VA
3
1/8
1,5
0,4
1,65
2,8
5,5
10,99
200
W4,5VA
4,5
3/16
2,3
0,5
2,53
4
7,85
15,7
100
W6VA
6
1/4
3
0,55
3,3
5,2
10,21
20,41
100
W8VA
8
5/16
4
0,6
4,4
6,8
13,35
26,69
100
W10VA
10
3/8
5
0,6
5,5
8,4
16,49
32,97
100
W13VA
13
1/2
6,5
0,65
7,15
10,8
21,21
42,39
100
W18VA
18
3/4
9
0,8
9,9
15,2
29,84
59,66
W20VA
20
3/4
10
0,8
11
17,6
34,56
W25VA
25
1
12,5
0,9
13,75
20,8
W30VA
30
1-1/4
15
0,95
16,5
W40VA
40
1-1/2
20
1
W50VA
50
2
25
W80VA
80
3
W100VA
100
4
C
• Material = flexible polyolefin with internal adhesive “hot melt” • Color = black • Shrink rate = 2:1 • Use temperature = -55 ºC to 100 ºC • Dielectric strength = ≥ 20 kV / mm • Longitudinal shrinkage = ≤ 10% • Water absorption ≤ 0,1% • Volumetric resistivity ≥1 x 1014Ω.cm
D W
REF
Internal Ø expanded (D) (mm)
Internal Ø after max. recovery (mm)
Length (C) (mm)
Wall thickness after máx. recovery (W) (mm)
100
WC 11/5
11
5,5
22
69,08
100
WC 16/7
16
7,5
40,84
81,64
50
WC 25/10
25
25,2
49,48
98,91
50
WC 32/16
22
33,2
65,19
130,31
50
1
27,5
40,8
80,11
160,14
40
1,46
45,1
64
125,66
51
1,46
56,1
80
157,08
Equivalent range Ø (mm) Mín.
Máx
Expanded Perímeter (mm)
1,1
6,05
8,8
34,54
75
2,2
8,26
12,8
50,24
10,5
80
2,3
11,56
20
78,5
32
16,5
90
2,5
18,16
25,6
100,48
WC 50/26
50
26
115
3,4
28,62
40
157
25
WC 70/37
70
37
120
2,5
40,73
56
219,8
251,2
25
WC 100/46
100
46
140
3,5
50,64
80
314
314
25
WC 120/57
120
57
155
3,5
62,75
96
376,8
47
Heat Shrinkables
Shrink tubes for high voltage • Shrink Temperature = starts at 90 °C • Provided in black and red
• Tracking high resistance • Material = flexible polyolefin • Use temperature = -55 ºC to 125 ºC REF (35 kV) WB20-35kV WB30-35kV WB50-35kV WB80-35kV WB100-35kV WB120-35kV WB180-35kV
Internal Ø expanded (D) (mm)
(pol)
20
3/4
30
Shrink for busbars with a thickness of 1/8 inch
Internal Ø after max. recovery (d) (mm)
Wall thickness after máx. recovery (W) (mm)
9 13
Equivalent range Ø (mm)
Expanded Perímeter (mm)
Mín.
Máx
M / Spool
4
9,91
16
31,4
62,8
15
4
14,31
24
49,48
94,2
15
50
2
20
4,5
22,02
40
80,11
157
15
80
3
32
4,5
35,23
64
125,66
251,2
15
100
4
40
4,5
44,03
80
157,08
314
15
120
5
48
5
52,84
96
188,49
376,8
15
70
5,5
77,06
144
282,74
565,2
15
180
Inch 1/4"
The heat blowers assist in carrying out various tasks in which heat is required, as in the case of shrink use.
REF HL1800 HL1500 HL2100
Potency 110V
220V
1500
1800
1400 1500
1400 2000
Temperature (ºC) 100 a 600 300 a 500 100 a 600
Temperature Control Continuous (back wheel)
1/8” X
E1 e E2 (switch) Digital (buttons “+” e “-”)
0,65 0,7 0,7
Summing the sides (mm)
Perimeter ÷ 3,14 (π)
Mín. 4,4
6,8
W8
8,5
4
3,17 X 6,35
19,04
6,06
4,95
7,6
W9
9,5
4,5 5
8,08
1/2"
3,17 X 12,7
31,74
10,11
1"
Weight (Kg)
(mm)
25,38
7/8"
HL 2100
Equivalent Φ ranger (mm)
3,17 X 9,52
5/8"
Heat blowers
HL 1500
Equivalent Diameter
3/8"
3/4"
HL 1800
Perimeter
Measure of busbar
Width of the flattened tube (mm)
3,17 X 15,87
3,17 X 19,05
3,17 X 22,22
3,17 X 25,4
38,08
44,44
50,78
57,14
12,13
14,15
16,17
18,20
1.1/4"
3,17 X 31,75
69,84
22,24
1.1/2"
3,17 X 38,1
82,54
26,29
1.3/4" 2" 2.1/4" 2.1/2" 2.3/4"
3,17 X 44,45 3,17 X 50,8 3,17 X 57,15 3,17 X 63,5 3,17 X 69,85
95,24 107,94 120,64 133,34 146,04
30,33 34,38 38,42 42,46 46,51
3"
3,17 X 76,2
158,74
50,55
3.1/4"
3,17 X 82,55
171,44
54,60
3.1/2"
3.3/4" 4"
3,17 X 88,9
3,17 X 92,25 3,17 X 101,6
184,14
196,84 209,54
58,64
62,69 66,73
4.1/2"
3,17 X 114,3
234,94
74,82
5"
3,17 X 127
260,34
82,91
5.1/2"
3,17 X 139,7
285,74
91,00
6"
3,17 X 152,4
311,14
99,09
Máx
Tubes options (codes)
Diameter (D) mm Normal
Shrinkable
5,5
8,4
W10
10,5
5,5
8,4
W10
10,5
5
7,15
10,8
W13
13,5
6,5
8,8
13,6
W16
16,5
8
9,9
15,2
W18
19
9
8,8
13,6
W16
16,5
8
9,9
15,2
W18
19
9 10
11
17,6
W20
21
9,9
15,2
W18
19
9
11
17,6
W20
21
10
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5 10
11
17,6
W20
21
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5 14
15,4
23,2
W28
29
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
15,4
23,2
W28
29
14
16,5
25,2
W30
31,5
15
16,5
25,2
W30
31,5
15
19,25
29,2
W35
36,5
17,5
19,25
29,2
W35
36,5
17,5
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
27,5
40,8
W50
≥ 50
25
34,1
48
W60
≥ 60
31
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
45,1
64
W80
≥ 80
41 46
50,6
72
W90
≥ 90
56,1
80
W100
≥ 100
51
45,1
64
W80
≥ 80
41 46
50,6
72
W90
≥ 90
56,1
80
W100
≥ 100
51
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
83,6
120
W150
≥ 150
75
83,6
120
W150
≥ 150
75
The highlighted items are the most used.
48
49
Heat Shrinkables
Shrink for busbars with a thickness of 3/16 inch Perimeter
Equivalent Diameter
Equivalent Φ ranger (mm)
(mm)
Summing the sides (mm)
Perimeter ÷ 3,14 (π)
Mín. 4,4
6,8
W8
8,5
4
4,76 X 6,35
22,22
7,08
4,95
7,6
W9
9,5
4,5
5,5
8,4
W10
10,5
5
5,5
8,4
W10
10,5
5
7,15
10,8
W13
13,5
6,5
Measure of busbar Inch 1/4"
3/8" 1/2"
5/8"
3/4"
7/8"
1" 1.1/4"
1.1/2"
1.3/4" 3/16” X
2"
4,76 X 9,52 4,76 X 12,7
4,76 X 15,87
4,76 X 19,05
4,76 X 22,22
4,76 X 25,4 4,76 X 31,75
4,76 X 38,1
4,76 X 44,45
4,76 X 50,8
34,92
41,26
47,62
53,96
60,32 73,02
85,72
98,42
111,12
9,10 11,12
13,14
15,17
17,18
19,21 23,25
27,30
31,34
35,39
4,76 X 57,15
123,82
39,43
2.1/2"
4,76 X 63,5
136,52
43,48
2.3/4"
4,76 X 69,85
149,22
47,52
3.1/4"
3.1/2"
3.3/4" 4"
4,76 X 76,2
4,76 X 82,55
4,76 X 88,9
4,76 X 95,25 4,76 X 101,6
161,92
174,62
187,32
200,02 212,72
51,57
55,61
59,66
63,70 67,75
4.1/2"
4,76 X 114,3
238,12
75,83
5"
4,76 X 127
263,52
83,92
5.1/2"
4,76 X 139,7
288,92
92,01
6"
4,76 X 152,4
314,32
100,10
The highlighted items are the most used.
50
28,56
2.1/4"
3"
Shrink for busbars with a thickness of 1/4 inch Máx
Tubes options (codes)
Diameter (D) mm Normal
Shrinkable
8,8
13,6
W16
16,5
8
9,9
15,2
W18
19
9
9,9
15,2
W18
19
9
11
17,6
W20
21
10
12,1
19,2
W22
23
11
11
17,6
W20
21
10
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
Perimeter
Equivalent Diameter
Equivalent Φ ranger (mm)
(mm)
Summing the sides (mm)
Perimeter ÷ 3,14 (π)
Mín.
1/4"
6,35 X 6,35
25,4
8,09
3/8"
6,35 X 9,52
31,74
10,11
Measure of busbar Inch
1/2"
5/8"
3/4"
6,35 X 12,7
6,35 X 15,87
6,35 X 19,05
38,1
44,44
50,78
12,13
14,15
16,17
Máx
Tubes options (codes)
Diameter (D) mm Normal
Shrinkable
5,5
8,4
W10
10,5
5
7,15
10,8
W13
13,5
6,5
8,8
13,6
W16
16,5
8
9,9
15,2
W18
19
9
8,8
13,6
W16
16,5
8
9,9
15,2
W18
19
9
11
17,6
W20
21
10
9,9
15,2
W18
19
9
11
17,6
W20
21
10
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5 10
11
17,6
W20
21
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
15,4
23,2
W28
29
14
12,1
19,2
W22
23
11
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
15,4
23,2
W28
29
14
15,4
23,2
W28
29
14
16,5
25,2
W30
31,5
15
15,4
23,2
W28
29
14
16,5
25,2
W30
31,5
15
15,4
23,2
W28
29
14
19,25
29,2
W35
36,5
17,5
16,5
25,2
W30
31,5
15
19,25
29,2
W35
36,5
17,5
16,5
25,2
W30
31,5
15
22
33,2
W40
41,5
20
19,25
29,2
W35
36,5
17,5
24,75
36,8
W45
46,5
22,5
19,25
29,2
W35
36,5
17,5
22
33,2
W40
41,5
20
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
27,5
40,8
W50
≥ 50
25
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
24,75
36,8
W45
46,5
22,5
34,1
48
W60
≥ 60
31
27,5
40,8
W50
≥ 50
25
34,1
48
W60
≥ 60
31
27,5
40,8
W50
≥ 50
25
39,6
56
W70
≥ 70
36
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
7/8"
1" 1.1/4"
1.1/2"
1/4” X
1.3/4" 2" 2.1/4" 2.1/2" 2.3/4"
3"
3.1/4"
6,35 X 22,22
6,35 X 25,4 6,35 X 31,75
6,35 X 38,1
6,35 X 44,45 6,35 X 50,8 6,35 X 57,15 6,35 X 63,5 6,35 X 69,85
6,35 X 76,2
6,35 X 82,55
57,14
63,5 76,2
88,9
101,6 114,3 127 139,7 152,4
165,1
177,8
18,20
20,22 24,27
28,31
32,36 36,40 40,45 44,49 48,54
52,58
56,62
56,1
80
W100
≥ 100
51
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
4.1/2"
6,35 X 114,3
241,3
76,85
67,1
96
W120
≥ 120
60
5"
6,35 X 127
266,7
84,94
5.1/2"
6,35 X 139,7
292,1
93,03
6"
6,35 X 152,4
317,5
101,11
67,1
96
W120
≥ 120
60
83,6
120
W150
≥ 150
75
83,6
120
W150
≥ 150
75
3.1/2"
6,35 X 88,9
190,5
60,67
3.3/4"
6,35 X 95,25
203,2
64,71
4"
6,35 X 101,6
215,9
68,76
34,1
48
W60
≥ 60
31
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51 41
45,1
64
W80
≥ 80
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51 46
50,6
72
W90
≥ 90
56,1
80
W100
≥ 100
51
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
83,6
120
W150
≥ 150
75
83,6
120
W150
≥ 150
75
The highlighted items are the most used.
51
Heat Shrinkables
Shrink for busbars with a thickness of 5/16 inch Perimeter
Equivalent Diameter
Equivalent Φ ranger (mm)
(mm)
Summing the sides (mm)
Perimeter ÷ 3,14 (π)
Mín.
7,93 X 6,35
28,56
9,10
Measure of busbar Inch 1/4" 3/8"
1/2"
5/8"
3/4"
7,93 X 12,7
7,93 X 15,87
7,93 X 19,05
41,26
47,6
53,96
11,11
13,14
15,16
17,18
60,32
19,21
1"
7,93 X 25,4
66,66
21,23
1.3/4" 2" 2.1/4" 2.1/2" 2.3/4"
3"
3.1/4"
3.1/2"
3.3/4" 4"
7,93 X 31,75
7,93 X 38,1
7,93 X 44,45 7,93 X 50,8 7,93 X 57,15 7,93 X 63,5 7,93 X 69,85
7,93 X 76,2
7,93 X 82,55
7,93 X 88,9
7,93 X 95,25 7,93 X 101,6
79,36
92,06
104,76 117,46 130,16 142,86 155,56
168,26
180,96
193,66
206,36 219,06
25,27
29,32
33,36 37,41 41,45 45,50 49,54
53,59
57,63
61,68
65,72 69,76
4.1/2"
7,93 X 114,3
244,46
77,85
5"
7,93 X 127
269,86
85,94
5.1/2"
7,93 X 139,7
295,26
94,03
6"
7,93 X 152,4
320,66
102,12
The highlighted items are the most used.
52
34,9
7,93 X 22,22
1.1/2"
5/16” X
7,93 X 9,52
7/8"
1.1/4"
Shrink for busbars with a thickness of 3/8 inch Máx
Tubes options (codes)
Diameter (D) mm Normal
Shrinkable
5,5
8,4
W10
10,5
5
7,15
10,8
W13
13,5
6,5
8,8
13,6
W16
16,5
8
9,9
15,2
W18
19
9
9,9
15,2
W18
19
9
11
17,6
W20
21
10
12,1
19,2
W22
23
11
11
17,6
W20
21
10
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
15,4
23,2
W28
29
14
15,4
23,2
W28
29
14
16,5
25,2
W30
31,5
15
16,5
25,2
W30
31,5
19,25
29,2
W35
16,5
25,2
19,25
Perimeter
Equivalent Diameter
Equivalent Φ ranger (mm)
(mm)
Summing the sides (mm)
Perimeter ÷ 3,14 (π)
Mín.
9,52 X 6,35
31,74
10,11
Measure of busbar Inch 1/4"
3/8"
1/2"
5/8"
9,52 X 9,52
9,52 X 12,7
9,52 X 15,87
38,08
44,44
50,78
12,13
14,15
16,17
Máx
Tubes options (codes)
Diameter (D) mm Normal
Shrinkable 8
8,8
13,6
W16
16,5
9,9
15,2
W18
19
9
8,8
13,6
W16
16,5
8
9,9
15,2
W18
19
9
11
17,6
W20
21
10
9,9
15,2
W18
19
9
11
17,6
W20
21
10
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5 10
11
17,6
W20
21
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
15,4
23,2
W28
29
14
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
15,4
23,2
W28
29
14
15
16,5
25,2
W30
31,5
15
36,5
17,5
15,4
23,2
W28
29
14
W30
31,5
15
29,2
W35
36,5
17,5
22
33,2
W40
41,5
20
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
27,5
40,8
W50
≥ 50
25
34,1
48
W60
≥ 60
31
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
3/4"
7/8" 1"
1.1/4"
1.1/2" 3/8” X
1.3/4"
9,52 X 19,05
9,52 X 22,22 9,52 X 25,4
9,52 X 31,75
9,52 X 38,1
9,52 X 44,45
57,14
63,48 69,84
82,54
95,24
107,94
18,20
20,22 22,24
26,29
30,33
34,38
2"
9,52 X 50,8
120,64
38,42
2.1/4"
9,52 X 57,15
133,34
42,46
2.1/2"
9,52 X 63,5
146,04
46,51
2.3/4"
9,52 X 69,85
158,74
50,55
3"
9,52 X 76,2
171,44
54,60
16,5
25,2
W30
31,5
15
16,5
25,2
W30
31,5
15
19,25
29,2
W35
36,5
17,5
19,25
29,2
W35
36,5
17,5
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
27,5
40,8
W50
≥ 50
25
34,1
48
W60
≥ 60
31
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
50,6
72
W90
≥ 90
46
45,1
64
W80
≥ 80
41 46
56,1
80
W100
≥ 100
51
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
3.1/4"
3.1/2"
3.3/4"
9,52 X 82,55
9,52 X 88,9
9,52 X 95,52
184,14
196,84
209,54
58,64
62,69
66,73
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
4.1/2"
9,52 X 114,3
247,64
78,87
67,1
96
W120
≥ 120
60
5"
9,52 X 127
273,04
86,96
83,6
120
W150
≥ 150
75
5.1/2"
9,52 X 139,7
298,44
83,6
120
W150
≥ 150
75
6"
9,52 X 152,4
323,84
4"
9,52 X 101,6
222,24
70,78
50,6
72
W90
≥ 90
56,1
80
W100
≥ 100
51
45,1
64
W80
≥ 80
41 46
50,6
72
W90
≥ 90
56,1
80
W100
≥ 100
51
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
95,04
83,6
120
W150
≥ 150
75
103,13
83,6
120
W150
≥ 150
75
The highlighted items are the most used.
53
Heat Shrinkables
Shrink for busbars with a thickness of 1/2 inch Perimeter
Equivalent Diameter
Equivalent Φ ranger (mm)
(mm)
Summing the sides (mm)
Perimeter ÷ 3,14 (π)
Mín. 8,8
13,6
W16
16,5
8
9,9
15,2
W18
19
9
12,7 X 6,35
38,1
12,13
9,9
15,2
W18
19
9
11
17,6
W20
21
10
11
17,6
W20
21
10
9,9
15,2
W18
19
9
Measure of busbar Inch 1/4"
3/8"
1/2"
5/8"
3/4"
7/8"
1"
1.1/4"
1.1/2"
12,7 X 9,52
12,7 X 12,7
12,7 X 15,87
12,7 X 19,05
12,7 X 22,22
12,7 X 25,4
12,7 X 31,75
12,7 X 38,1
44,44
50,78
57,14
63,5
69,84
76,2
88,9
101,6
14,15
16,17
18,20
20,22
22,24
24,27
28,31
32,36
1/2” X 1.3/4" 2" 2.1/4" 2.1/2"
2.3/4"
3"
3.1/4"
3.1/2" 3.3/4"
12,7 X 44,45 12,7 X 50,8 12,7 X 57,15 12,7 X 63,5
12,7 X 69,85
12,7 X 76,2
12,7 X 82,55
12,7 X 88,9 12,7 X 95,25
127 139,7 152,4
165,1
177,8
190,5
203,2 215,9
36,40 40,45 44,49 48,54
52,58
56,62
60,67
64,71 68,76
12,7 X 101,6
228,6
72,80
4.1/2"
12,7 X 114,3
254
80,89
5"
12,7 X 127
279,4
88,98
5.1/2"
12,7 X 139,7
304,8
97,07
12,7 X 152,4
The highlighted items are the most used.
54
114,3
4"
6"
Shrink for busbars with a thickness of 5/8 inch
330,2
105,16
Máx
Tubes options (codes)
Diameter (D) mm Normal
Shrinkable
Measure of busbar Inch
(mm)
1/4"
Perimeter
Equivalent Diameter
Equivalent Φ ranger (mm)
Summing the sides (mm)
Perimeter ÷ 3,14 (π)
Mín.
15,87 X 6,35
44,44
14,15
Máx
Tubes options (codes)
Diameter (D) mm Normal
Shrinkable
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
11
17,6
W20
21
10
11
17,6
W20
21
10
12,1
19,2
W22
23
11
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
13,75
20,8
W25
26
12,5
11
17,6
W20
21
10
15,4
23,2
W28
29
14
12,1
19,2
W22
23
11
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
13,75
20,8
W25
26
12,5
15,4
23,2
W28
29
14
12,1
19,2
W22
23
11
15,4
23,2
W28
29
14
13,75
20,8
W25
26
12,5
16,5
25,2
W30
31,5
15
15,4
23,2
W28
29
14
16,5
25,2
W30
31,5
15
16,5
25,2
W30
31,5
15
19,25
29,2
W35
36,5
17,5
16,5
25,2
W30
31,5
15
19,25
29,2
W35
36,5
17,5 17,5
15,4
23,2
W28
29
14
16,5
25,2
W30
31,5
15
15,4
23,2
W28
29
14
16,5
25,2
W30
31,5
15
16,5
25,2
W30
31,5
15
19,25
29,2
W35
36,5
17,5
19,25
29,2
W35
36,5
17,5
16,5
25,2
W30
31,5
15
19,25
29,2
W35
36,5
17,5
19,25
29,2
W35
36,5
17,5
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
27,5
40,8
W50
≥ 50
25
34,1
48
W60
≥ 60
31
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
67,1
96
W120
83,6
120
W150
3/8"
1/2"
5/8"
15,87 X 12,7
15,87 X 15,87
50,78
57,14
63,48
16,17
18,20
20,22
3/4"
15,87 X 19,05
69,84
22,24
7/8"
15,87 X 22,22
76,18
24,26
1"
15,87 X 25,4
82,54
26,29
1.1/4"
1.1/2"
5/8” X
15,87 X 9,52
15,87 X 31,75
15,87 X 38,1
95,24
107,94
30,33
34,38
1.3/4"
15,87 X 44,45
120,64
38,42
2"
15,87 X 50,8
133,34
42,46
2.1/4"
15,87 X 57,15
146,04
46,51
2.1/2"
15,87 X 63,5
158,74
50,55
2.3/4"
15,87 X 69,85
171,44
54,60
3"
3.1/4"
3.1/2" 3.3/4"
15,87 X 76,2
15,87 X 82,55
15,87 X 88,9 15,87 X 95,25
184,14
196,84
209,54 222,24
58,64
62,69
66,73 70,78
4"
15,87 X 101,6
234,94
74,82
60
4.1/2"
15,87 X 114,3
260,34
82,91
≥ 120
60
≥ 150
75
5"
15,87 X 127
285,74
91,00
5.1/2"
15,87 X 139,7
311,14
99,09
83,6
120
W150
≥ 150
75
83,6
120
W150
≥ 150
75
100,1
144
W180
≥ 180
90
6"
15,87 X 152,4
336,54
107,18
19,25
29,2
W35
36,5
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
27,5
40,8
W50
≥ 50
25
34,1
48
W60
≥ 60
31
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
45,1
64
W80
≥ 80
41 46
50,6
72
W90
≥ 90
56,1
80
W100
≥ 100
51
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
83,6
120
W150
≥ 150
75
83,6
120
W150
≥ 150
75
83,6
120
W150
≥ 150
75
100,1
144
W180
≥ 180
90
The highlighted items are the most used.
55
Shrink for busbars with a thickness of 1/16 Inch Perimeter
Equivalent Diameter
Equivalent Φ ranger (mm)
(mm)
Summing the sides (mm)
Perimeter ÷ 3,14 (π)
Mín.
1,59 X 6,35
15,88
5,06
Measure of busbar Inch 1/4”
3/8” 1/2”
1,59 X 9,52 1,59 X 12,7
22,22 28,58
7,08 9,10
5/8”
1,59 X 15,87
34,92
11,12
3/4”
1,59 X 19,05
41,28
13,15
7/8”
1”
1.1/4”
1.1/2”
1.3/4”
1,59 X 22,22
1,59 X 25,4
1,59 X 31,75
1,59 X 38,1
1,59 X 44,45
47,62
53,98
66,68
79,38
92,08
15,17
17,19
21,24
25,28
29,32
1/16” X 2” 2.1/4” 2.1/2” 2.3/4”
1,59 X 50,8 1,59 X 57,15 1,59 X 63,5 1,59 X 69,85
104,78 117,48 130,18 142,88
33,37 37,41 41,46 45,50
3”
1,59 X 76,2
155,58
49,55
3.1/4”
1,59 X 82,55
168,28
53,59
3.1/2”
3.3/4”
4”
1,59 X 88,9
1,59 X 92,25
1,59 X 101,6
180,98
187,68
206,38
57,64
59,77
65,73
4.1/2”
1,59 X 114,3
231,78
73,82
5”
1,59 X 127
257,18
81,90
5.1/2”
1,59 X 139,7
282,58
89,99
6”
1,59 X 152,4
307,98
99,09
Máx
Tubes options (codes)
Diameter (D) mm Normal
Shrinkable 3,5
3,85
6
W7
7
4,4
6,8
W8
8,5
4
4,95
7,6
W9
9,5
4,5
4,95
7,6
W9
9,5
4,5
5,5
8,4
W10
10,5
5
7,15
10,8
W13
13
6,5
8,8
13,6
W16
16,5
8
8,8
13,6
W16
16,5
8
9,9
15,2
W18
19
9
9,9
15,2
W18
19
9
11
17,6
W20
21
10
12,1
19,2
W22
23
11
11
17,6
W20
21
10
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5
12,1
19,2
W22
23
11
13,75
20,8
W25
26
12,5 14
15,4
23,2
W28
29
16,5
25,2
W30
31,5
15
15,4
23,2
W28
29
14
16,5
25,2
W30
31,5
15
19,25
29,2
W35
36,5
17,5
19,25
29,2
W35
36,5
17,5
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
22
33,2
W40
41,5
20
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
24,75
36,8
W45
46,5
22,5
27,5
40,8
W50
≥ 50
25
27,5
40,8
W50
≥ 50
25
34,1
48
W60
≥ 60
31
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
34,1
48
W60
≥ 60
31
39,6
56
W70
≥ 70
36
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
39,6
56
W70
≥ 70
36
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
45,1
64
W80
≥ 80
41 46
50,6
72
W90
≥ 90
56,1
80
W100
≥ 100
51
45,1
64
W80
≥ 80
41
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
50,6
72
W90
≥ 90
46
56,1
80
W100
≥ 100
51
56,1
80
W100
≥ 100
51
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
67,1
96
W120
≥ 120
60
83,6
120
W150
≥ 150
75
83,6
120
W150
≥ 150
75
Connectors and Terminals
The highlighted items are the most used.
56
57
Connectors and Terminals
Conectores Material: PA 66 (Nylon 66) Use temperature: -40°C a 85°C Flammability: UL94 V2
F1182
F1113
F1112
F1182
F3032
F3039
F3038
Connector 2 ways with fixation for blade fuse holder
Connector 2 ways for blade fuse holder
Connector 2 ways for blade fuse holder “MAX”
F1182
F2009
F2011
F2013
Connector 1 way for long male terminal 6.3
Connector 1 way for short male terminal 6.3
Connector 1 way for female terminal lockable 6.3
F1182
F1180
F1186
F1184
F1970
F2340
Connector 1 way for female terminal without lock 6.3
Connector 1 way for female terminal 2.8
Connector 1 way for female terminal 4.8
F2631
F2015
F2618
Connector for alternator
Connector 3 ways for vehicule headlight
Connector 3 ways for female terminal 6.3
F1113
58
F1182
F1108
F2090
F2100
F2614
Connector 1 way for terminal flag 6.3
Connector 1 way for terminal flag 4.8
Connector 2 ways for femae terminal 6.3
F1113
F1182
F1185
F2014
F1183
F1184
F2619
F2621
F2622
Connector 3 ways for male terminal 6.3
Connector 4 ways for female terminal 6.3
Connector 4 ways for male terminal 6.3
F1113
F1182
F1113
F1182
F1182
F1113
F1182
F2615
F2616
F2617
F2642
F2630
F2625
Connector 2 ways for male terminal 6.3
Connector 2 ways in“ T “ for female terminal 6.3
Connector 2 ways in “T” for male terminal 6.3
Connector 5 ways with fixative relay
Connector 5 ways for relay
Connector 6 ways for male terminal 6.3
59
Connectors and Terminals
Fuse holders
F1182
F1182
F1113
F2623
F2626
F2627
Connector 6 ways for female terminal 6.3
Connector 8 ways for female terminal 6.3
Connector 8 ways for male terminal 6.3
Kit – Connector with terminals
FM3032
FM3039
FM3038
Fuse holder with tabs for fixing
Fuse holder
Fuse holder “ MAX”
Cable of 1,5 mm²
Cable of 4,0 mm²
Cable of 1,5 mm²
FD3032
FD3038
Kit fuse holder
Kit fuse holder “MAX”
(1 connector with tabs and 2 female terminals 6.3)
(1 connector and 2 terminals flag 6.3)
Socket
60
F2702
F2703
F2704
Kit connector 2 ways in “T” (male and female) with 4 brass terminals
Kit connector 3 ways (male and female) with 6 brass terminals
Kit connector 4 ways (male and female) with 8 brass terminals
F2705
F2706
F2708
Kit connector 5 ways with 5 terminals (for relay)
Kit connector 6 ways (male and female) with 12 brass terminals
Kit connector 8 ways (male and female) with 16 brass terminals
FM2015
FD2015
FM2018
Vehicle headlamp (cable of 1,5 mm²)
Kit for vehicle headlamp (1 connector and 3 terminals)
Veicle headlamp (Lamp H7)
F3040
F3041
Universal for vehicle headlamps 2 poles - cable1,0 mm² - Nylon 66 socket - Operating temperature: -40ºC a 85ºC
Universal for vehicle headlamps 1 pole - cable 1,0 mm² - Nylon 66 socket - Operating temperature: -40ºC a 85ºC
61
Connectors and Terminals
Terminals Material: brass The terminal images are in the real size.
62
F1112
F1113
F1114
Short male 6.3
Long male 6.3 lockable
Male lockable 2.8
F1115
F1180
F1181
Male without lock 2.8
Female without lock 6.3
Female lockable 9.7 (big)
F1183
F1184
F1108
Flag without lock 6.3
Flag lockable 7.2 (farol de veículos)
Flag without lock 4.8
F1102
F1124
F1126
Eye bolt 3 mm
Eye bolt 1/8”
Eye bolt 5/32”
F1132
F1133
F1142
Eye bolt 3/16”
Eye bolt 3/16”
Eye bolt 6 mm
F1182
F1182BG
F1185
Female lockable 6.3
Female lockable 6.3 (big barrel)
Female lockable 4.8
F1186
F1186CT
F1188
F1143
F1141
F1144
Female without lock 2.8
Female lockable 2.8
Hermaphrodite 6.3
Eye bolt 8 mm
Eye bolt ¼” (for cables 2,5 a 6 mm)
Eye bolt ¼” (for cables 1,5 a 4 mm)
63
F1178
F1160
F1162
Eye bolt 8,5 mm
Eye bolt 3/8” (thickness 0,6 mm)
Eye bolt 3/8” (thickness1,0 mm)
F1135
F1151
Fork 3/16”
Fork ¼”
Battery Grips
64
F2003
F2004
F2005
Galvanized steel to 150 A
Galvanized steel to 100 A
Galvanized steel with brass ferrule to 150 A
2015 | 2a Edição
51 3201.2477 Estrada do Socorro, 380 Arroio da Manteiga São Leopoldo - RS 93135.390 SAC: 0800.7042477
www.frontec.com.br
MADE TO MAKE IT WELL DONE.