Transcript
Rainstrasse 35 CH-6314 Unteraegeri, Switzerland Phone: +41 41-752 08 08, Fax: +41 41 752 08 02
September 2011
Professional Twin DAB/DAB+/FM Receiver with Audio Channel Monitor and Alarm Unit
The DRR-2TM/EU is a dual tuner DAB receiver housed in a 1RU 19” rack mountable chassis. Tthe DRR2TM can provide the alarm outputs required for the broadcast industry for monitoring their DAB services. With 2 tuners, the DDR2T-M DAB monitor will have the ability to independently monitor 2 audio services on separate DAB ensembles. Each tuner will have 5 alarm outputs. The alarm outputs will be open collector, designed to interface into existing alarm monitoring or SCADA systems. These 1-unit-high devices are extremely space-saving, because they can be mounted directly above each other in the rack (virtually no heat). Outputs (each tuner): Analog L / R and S/PDIF (RCA) and optical. Optional cable adapter with up to 6m (18ft) usable at AES-EBU interfaces. Antenna Input: Ffemale 75 ohm or with optional BNC adapter.
www.digitalview.eu.com
DRR-2TM/EU Specification (european version) Type:
Dual Tuner Digital / Analog Radio Receiver (DAB+/FM)
Frequency Range
FM: 87.50 to 108MHz, DAB+ Band 3: 174.928 to 239.20MHz, L-Band: 1452.960 to 1490.624MHz
Supported Audio Formats
AAC+
Frequency Response
FM: Typically 20Hz - 12.5kHz @ -3db, DAB, DAB+: Typically 20Hz - 20kHz and only limited by
Sensitivity
FM -108dbm typical, DAB, DAB+ and L-Band - 97dbm typical
Signal to Noise
FM 50dbA typical, DAB, DAB+ 99dbA typical
broadcast, Analog Audio output: 20Hz - 20KHz
THD Distortion (Analog Output)
0.01% typical
Signal to Noise (Analog Output)
97db typical
Antenna Input Impedance - DAB, DAB+, FM
75 ohm - "F" type connector
Digital Audio Output/s
S/PDIF - Optical and Coaxial
Analog Audio Output
L & R Channels (RCA)
FM reception delay
approx 90 ms
Control Interface
RS232 / V24 (9 pin “D” conn.)
Input Voltage / Frequency
180 - 265VAC / 47-60Hz
Power Consumption (max.) / Standby
< 2.5W / < 0.7W
Rackmount stackable
direct, no blank units needed between the units
Alarm outputs
12cct socket, 50V 300ma open collector
Operating Temperature / Humidity
0 - 50°C / 5% -90% Non-condensing
Dimensions (max.)
482mm(W) x 207mm(D) x 44mm(H)
Warranty / Version
One Year, european version
Accessories: AES-EBU cable adapter, DAB antennas, RF distribution ... on request.
Y o u r
b r o a d c a s t
p a r t n e r
E - M a i l :
[email protected]
www.digitalview.eu.com
www.sumatronic.ch
Rainstrasse 35 CH-6314 Unteraegeri, Switzerland Phone: +41 41-752 08 08, Fax: +41 41 752 08 02
Accessories
Cable for the transition from S/PDIF (RCA) to AES-EBU XLR(m). Twin cable for the two tuners. length 3m Cable for the transition from S/PDIF (RCA) to AES-EBU XLR(m). Twin cable for the two tuners. length 6m
EUR (excl. VAT). 39.00 48.00
Adapter for antenna-connector: F(m) - IEC(m)
4.80
Adapter for antenna-connector: F(m) - BNC(f)
5.80
RF splitter for connecting two receivers to one antenna: 1 input, 2 outputs, F(f) connectors, attenuation per output: 3.5 dB
on request
RF splitter for connecting four receivers to one antenna: 1 input, 4 outputs, F(f) connectors, attenuation per output: 7 dB
on request
DAB-antenna, 5-elements, 75 ohms
71.00
5 elements, vertical, gain: approx. 6.5 dB, mast-fixture up to 60 cm. whithout mast or boom
DAB-Antenna, 8-elements, 75 ohms
145.00
5 elements, vertical, gain: approx. 8 dB, mast-fixture up to 60 cm. whithout mast or boom
LAT 100 antenna holder, aluminum tube Ø 50 mm. Wall distance: 1000 mm, mounting plate: 150 x 150 mm, vertical tube Ø 40 mm, length 400 mm
RS232 data cable for connecting the DAB receiver to a PC Control-Software
241.00
on request free from webseite