Preview only show first 10 pages with watermark. For full document please download

Programming Manual

   EMBED


Share

Transcript

PROGRAMMING MANUAL CODE : 00Z XEA21SUPME LEAD-FREE SOLDER MODEL ELECTRONIC CASH REGISTER MODEL XE-A21S CONTENTS ■ LEAD-FREE SOLDER CHAPTER 1. MASTER RESET AND PROGRAM RESET . . . . . . 1 - 1 CHAPTER 2. PROGRAM MODE . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 1 CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE. . . . . . . . . . . . . . . . . . 3 - 1 Parts marked with "!" are important for maintaining the safety of the set. Be sure to replace these parts with specified ones for maintaining the safety and performance of the set. This document has been published to be used for after sales service only. The contents are subject to change without notice. ■ LEAD-FREE SOLDER The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder. The alphabet following the “LF” mark shows the kind of lead-free solder. Example: Lead-Free 5mm Solder composition code (Refer to the table at the right.) a Solder composition Solder composition code Sn-Ag-Cu a Sn-Ag-Bi Sn-Ag-Bi-Cu b Sn-Zn-Bi z Sn-In-Ag-Bi i Sn-Cu-Ni n Sn-Ag-Sb s Bi-Sn-Ag-P Bi-Sn-Ag p (1) NOTE FOR THE USE OF LEAD-FREE SOLDER THREAD When repairing a lead-free solder PWB, use lead-free solder thread. Never use conventional lead solder thread, which may cause a breakdown or an accident. Since the melting point of lead-free solder thread is about 40°C higher than that of conventional lead solder thread, the use of the exclusive-use soldering iron is recommendable. (2) NOTE FOR SOLDERING WORK Since the melting point of lead-free solder is about 220°C, which is about 40°C higher than that of conventional lead solder, and its soldering capacity is inferior to conventional one, it is apt to keep the soldering iron in contact with the PWB for longer time. This may cause land separation or may exceed the heat-resistive temperature of components. Use enough care to separate the soldering iron from the PWB when completion of soldering is confirmed. Since lead-free solder includes a greater quantity of tin, the iron tip may corrode easily. Turn ON/OFF the soldering iron power frequently. If different-kind solder remains on the soldering iron tip, it is melted together with lead-free solder. To avoid this, clean the soldering iron tip after completion of soldering work. If the soldering iron tip is discolored black during soldering work, clean and file the tip with steel wool or a fine filer. XE-A21S LEAD-FREE SOLDER CHAPTER 1. MASTER RESET AND PROGRAM RESET 1. MASTER RESETTING Master resetting clears the entire memory and resumes initial values. Master resetting can be accomplished by using the following procedure: Procedure : 1) Unplug the AC cord from the wall outlet, or set the mode switch to OFF position. 2) Let the ECR be without the memory backup battery. 3) Wait over 1 minute for discharging. 4) Set the mode switch to any position except OFF. 5) Plugin the AC cord to the wall outlet, or turn the mode switch from OFF position to another position. The master reset can also be accomplished in the following case. In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the power has been restored. (This is because if power failure occurs with no battery attached to the machine, all the memories are lost and the machine does not work properly after power recovery; this requires the master reset operation.) 2. PROGRAM RESETTING (INITIALIZATION) This resetting resumes the initial program without clearing memory. This resetting can be operated at below sequence in PGM mode. Procedure: 1) Unplug the AC cord from the wall outlet. 2) Wait over 1 minute for discharging. 3) Set the mode switch to the PGM position. 4) While holding down the FEED key, plugin the AC cord to the wall outlet. Note: In case power failure occurs when the machine has no battery attached to it, the master reset operation is automatically performed after the power has been restored. XE-A21S MASTER RESET and program reset 1–1 CHAPTER 2. PROGRAM MODE 1. READING STORED PROGRAMS The machine allows you to read every program stored in the PGM mode. ■ Key sequence for reading stored program Report name Key sequence Programming report 1 CA/AT Programming report 2 2 3 CA/AT [Auto] key programming report 1 3 CA/AT Printer density programming report 3 3 CA/AT PLU programming report (*1) Start PLU code @/FOR End PLU code PLU (*1) PLU code range can be specified by entering the start and end numbers according to the following procedure. When specifying a single time interval, PLU code, the start number has only to be entered. ■ SAMPLE PRINTOUTS 1. Programming report 1 F 44 CASH HEADER 008 05/02/2006 12:34PM 123456#1234 01 BETTY___ DATE/TIME/CLERK NO F 45 CHECKxxx MACHINE NO. /CC-NO. / CLERK NAME F 46 CHRAGExx 008 MODE TITLE *PGM* D01 T1234 073 DPT.01xxxxxx -1234.56 D02 DPT.02 T1234 D99 DPT.99 T1234 : : 073 -1234.56 071 0.00 DEPT CODE/TAXABLE/ PROGRAM (*1) TEXT/PRICE WITH SIGN (MAX department is decided by PGM selection.) 008 F 47 CHARGE00 F 48 CONV 1 AAAA 9999.9999 F 49 CONV 2 F 50 ****CID : F 67 COPY F 68 EJ F 69 EJ END SHARP PRESENTS THE BEST ECR FUNCTION NO. /TEXT/PROGRAM (*2) F01 ( - ) xx 007 -1000.00 000 F02 % 1xxxx L100.00% T1234 -10.00% F04 NET1 F05 TAX1 ST F06 GRS TAX1 F07 RFD TAX1 F08 TAX1 F09 TX1 EXPT : : F25 GRS MTAX F26 RFD MTAX 7 F27 M-TAX F28 GST EXPT : : 9 F40 ***RAxxx 9 F41 ***POxxx F42 TRANS CT F43 NET3 AMOUNT WITH SIGN FUNCTION NO. /TEXT /HALO #5 #6 #7 #10 #11 #15 #19 #35 #50 T1 FUNCTION NO. /TEXT /HALO T2 T3 T4 C#01 C#02 : C#25 XE-A21S FUNCTION NO. /TEXT/PROGRAM (*4) CURRENCY SYMBOL/RATE FUNCTION NO. /TEXT LOGO TEXT (It is according with LOGOFORMAT.) SHARP IS THE BEST FUNCTION NO. /TEXT /PROGRAM (*2) HALO WITHOUT SIGN/ RATE WITH SIGN FUNCTION NO./TEXT FUNCTION NO. /TEXT /PROGRAM (*3) FUNCTION NO. /TEXT /PROGRAM (*3) FUNCTION NO. /TEXT /PROGRAM (*3) PROGRAM MODE 2–1 00000000 00000000 00000000 0000 0 00000000 00 007 007 10.0000% / 1.00 1 0.11 2 0.23 3 0.57 4 0.78 5 1.11 4.0000% 0.10 5.0000% 0.20 -----CLERK.01 CLERK.02 : CLERK.25 (JOB# 5) FUNCTION SELECT (JOB# 6) PRINT FUNCTION (JOB# 7) RECEIPT PRINT FORMAT (JOB#10) POWER SAVING PROGRAMMING (JOB#11) LOGO FORMAT (JOB#15) FUNCTION SELECT2 (JOB#19) DOUGHNUT TAX EXEMPT (JOB#35) ONLINE Timeout time (JOB#50) Thermal printer density TAX1 RATE CYCLE TAX /BREAK POINT AMOUNT TAX2 RATE LOWER TAX LIMIT TAX3 TAX4 ("------": INHIBIT) Clerk No. /Clerk name : VARIOUS PROGRAM Refer to the programming section about the data of each JOB. 2. Programming report 2 (*1) DEPT PROGRAM : ABC A: REGISTRATION TYPE A NORMAL 0 SICS 1 HEADER DATE/TIME/CLERK NO B: LIMITATION DIGITS (*2) = 0 to 7 BETTY___ 123456#1234 C: AMOUNT ENTRY TYPE 0 Open 1 Preset 2 Open and Preset 3 *PGM* #61 00000000 #62 00000000 #63 00000000 #64 00000000 #65 00000000 #66 00000000 #67 00000000 #68 00000000 #69 00000000 #70 00000000 #71 $00000000000.00 GT2 #72 $00000000000.00 GT3 #76 Z1 0000 #77 Z2 0000 #85 ___$ #86 00 #87 TRAINING #88 0 #90 0 #95 99 (*2) (-)/[%] PROGRAM : ABC A ENABLE 0 DISABLE 1 B: ENTRY FOR SBTL B ENABLE 0 DISABLE 1 C: LIMITATION DIGITS (for (-) key) = 0 to 7 (0 FIXED for [%n]) OTHERS1 OTHERS2 OTHERS3 OTHERS4 OTHERS5 OTHERS6 OTHERS7 OTHERS8 OTHERS9 OTHERS10 GT2 GT3 GENERAL Z1 RESET COUNTER GENERAL Z2 RESET COUNTER DOMESTIC CURRENCY SYMBOL TRAINING CLERK TRAINING MODE TEXT LANGUAGE MODE (For the fixed messages) EJ/PLU MEMORY TYPE (0: TYPE, 1: TYPE2) : OTHERS PROGRAM Refer to the programming section about the data of each JOB. A No 0 Yes 1 B: Entry of amount tendered (JOB#61) (JOB#62) (JOB#63) (JOB#64) (JOB#65) (JOB#66) (JOB#67) (JOB#68) (JOB#69) (JOB#70) MAX NUBMER OF DEPT (*3) MEDIA PROGRAM : ABC A: Footer print on Receipt MACHINE NO./CC-NO./ CLERK NAME MODE TITLE C Inhibited A: ENTRY FOR ITEM 01 05/02/2006 12:34PM 3. [Auto] key programming report B Non compulsory (Cash, check), Inhibit (Credit) 0 HEADER Compulsory 1 05/02/2006 12:34PM DATE/TIME/CLERK NO 123456#1234 01 BETTY___ MACHINE NO. /CC-NO. / CLERK NAME C: LIMITATION DIGITS (0=INHIBIT) = 0 to 8 *PGM* #01 (*4) CONVERSION PROGRAM : AB A: OPEN RATE ENTRY 1 0 0 0 CASH A ENABLE 0 DISABLE 1 B: PRESET RATE ENTRY MODE TITLE B ENABLE 0 DISABLE 1 ------ KEY TEXT DELETE (NO KEY) 4. Printer density report HEADER DATE/TIME/CLERK NO 05/02/2006 12:34PM 123456#1234 01 BETTY___ *PGM* #01 50 10 : 0123456789AB 20 : 0123456789AB 30 : 0123456789AB 40 : 0123456789AB 50 : 0123456789AB 60 : 0123456789AB 70 : 0123456789AB 80 : 0123456789AB 90 : 0123456789AB XE-A21S PROGRAM MODE 2–2 MACHINE NO. /CC-NO. / CLERK NAME MODE TITLE Thermal printer density Printing Sample (Light & Shade value between 10 to 90.) 5. PLU data report 2) DEPT FUNCTION PROGRAMMING 0 ABCDEFGH HEADER @/FOR DPTn DEPT SHIFT 01 05/02/2006 12:34PM DATE/TIME/CLERK NO BETTY___ 123456#1234 0 MACHINE NO. /CC-NO. /CLERK NAME YY MODE TITLE *PGM* 0001-1200 1 -1234.56 P001 PLU001xxxxxx : : START CODE/ END CODE (RANGE DATA) PLU CODE/Associated DEPT code/ Type (*1) ---- A No 0 Yes 1 ★ B No 0 Yes 1 ★ Y SUBDEPT 0 PLU 1 C: Taxable 2 1) PRICE PROGRAMMING FOR [DEPT.] & (-) KEYS 0 Yes 1 DPTn XXXXXX 0 Yes 1 DEPT SHIFT 0 XXXXXX DEPT# 0 SICS 1 F: SIGN B DPTn (-) SBTL + 0 - 1 ★ ★ G: LIMITATION DIGITS = 0 to 7 YY: Department Code (01 to 99) 0 : OPEN PRICE REGISTRATION INHIBIT. XXXXXX: Unit price (Max. 6digits) If a price is set for a department which amount entry type is “INHIBIT” or “OPEN”, its amount entry type is set as below automatically. 1 ★ A NORMAL CA/AT ★ D No E: REGISTRATION TYPE 0 C No D: Taxable 1 2. USER PROGRAMMING “PRESET” @/FOR B: Taxable 3 (*1) PROGRAM : Y YY ABCDEFGH A: Taxable 4 When PLU is deleted at the programming JOB. Y: PROGRAM DEPT# YY: Department code (01 to 99) TEXT/PRICE WITH SIGN NOTE : The deleted PLU is not printed. P001 CA/AT DPTn H: AMOUNT ENTRY TYPE “INHIBIT” “OPEN & PRESET” 1 “OPEN” MRS = 0 D Inhibited 0 Open 1 Preset 2 Open & Preset 3 MRS = 00010071 (TAXABLE 1, NORMAL, SIGN (+), HALO = 7, OPEN) XE-A21S PROGRAM MODE 2–3 ★ 3) (-) & [%] KEY FUNCTION PROGRAMMING 5) PROGRAMMING FOR CONVERSION 0 0 (-) ABCDEFGH @/FOR CA/AT AB %n A: Taxable 4 A No 0 Yes 1 B: Taxable 3 0 Yes 1 C: Taxable 2 0 Yes 1 D: Taxable 1 0 Yes 1 A ENABLE 0 DISABLE 1 ★ B ENABLE 0 DISABLE 1 ★ MRS = 00 ★ 6) PROGRAMMING FOR FUNCTION KEYS 0 D No CA/AT B: PRESET RATE ENTRY ★ C No CONV A: OPEN RATE ENTRY ★ B No @/FOR ★ RA A @/FOR CA/AT PO TAX (for Manual-TAX) E: SIGN E + 0 - 1 F: ENTRY FOR ITEM A: LIMITATION DIGITS (0 = INHIBIT) ★ = 0 to 7 (for Manual TAX) = 0 to 9 (for RA, PO) F ENABLE 0 DISABLE 1 ★ MRS = 7 (Manual TAX), 9 (RA, PO) 7) PROGRAMMING FOR MEDIA KEYS G: ENTRY FOR SBTL G ENABLE 0 DISABLE 1 ([#/ST] key is used for programming of CASH.) ★ 0 ABC CHK @/FOR H: LIMITATION DIGITS (for (-) key) = 0 to 7 CH CA/AT #/ST (for CASH) 0 : OPEN PRICE REGISTRATION INHIBIT (for (-) KEY) 0 : FIXED for [%] MRS = 00001007 (NON-TAXABLE, MINUS SIGN, ITEM&SBTL, HALO = 7) A: Footer print on Receipt 4) RATE PROGRAMMING FOR [%] AND CONVERSION KEY. No 0 Yes 1 B: Entry of amount tendered %n CA/AT CONV XXX.XX: Rate for % (0.00 to 100.00) 0 Compulsory 1 C: LIMITATION DIGITS (0=INHIBIT) = 0 to 8 XXXX.XXXX: Rate for CONVERSION (0.0000 to 9999.9999) MRS = 008 The DECIMAL POINT must be entered for setting the decimal digits. MRS = 0.00 (%n) 0.0000 (CONVERSION) XE-A21S PROGRAM MODE 2–4 B Non compulsory (Cash, Check), Inhibit (Credit) (0 FIXED for RA/PO) (RATE): ★ (0 FIXED for RA/PO) 0 (RATE) A ★ 11) PROGRAMMING OF DEPARTMENT TEXT 8) DATA PROGRAMMING FOR PLU There are programmed by below key sequence. The PLU code is increment automatically when one programming data of a PLU is set. And it is operated continuously until depressing the [CA/AT] key. The JOB is automatically finalized when a maximum PLU code is programmed. NO CHANGE SBTL 1 DPTn SBTL (CHARACTERS) CA/TA DEPT SHIFT DPTn XX DEPT CODE DEPT# (Basic programming sequence) Basic operation consists of below 2 kinds. XX: Department Code (1 to 99) XXXX PLU CODE PLU (CHATACTERS): CHARCTER (Max. 12 Characters) DPTn (DATA) DEPT CODE DEPT SHIFT DPTn DEPT# (DATA) SBTL Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER BY NUMERIC KEYS IS AS FOLLOWS: CA/AT YYY 3 [00] KEY (Code increment) (Code entry) YYY: CHARACTER CODE (3 DIGITS) (or [000] KEY ACCORDING TO PGM PRESET) PLU XXXX PLU CODE SBTL (DATA) MRS = DEPT. xx (xx: DEPT Code) CA/AT 12) PROGRAMMING OF PLU TEXT (Code increment) (Code entry) NO CHANGE SBTL 2 9) PROGRAMMING OF DEPARTMENTS TO BE ASSOCIATED WITH PRICE PRESET PLU XXXX PLU CODE (CHARACTERS) SBTL CA/AT (Code increment) PLU DELETE (INHIBIT) (Code entry) 0 XXXX PLU CODE PLU DPTn YYYYYY DEPT SHIFT XXXX: PLU CODE (1 to 1200) CA/AT (CHARACTERS): CHARACTER (Max. 12 Characters) DPTn 0 YYYYYY ZZ DEPT# DEPT CODE Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER BY NUMERIC KEYS IS AS FOLLOWS: SBTL (Code increment) (Code entry) YYY3 [00] KEY YYY: CHARACTER CODE (3 DIGITS) XXXX: PLU CODE (1 to 1200) ZZ: DEPT CODE (1 to 99) (or [000] KEY ACCORDING TO PGM PRESET) YYYYYY: UNIT PRICE (6 digits) MRS = PLU.xxxx (xxxx: PLU code) DELETE means to be set as a inhibited PLU in memory. When it is assigned some DEPT for the inhibited (deleted) PLU, the PLU is set the MRS value except its price. 13) PROGRAMMING OF FUNCTION TEXT NO CHANGE MRS = DEPT1, Price: 0 (Create: PLU001 to PLU1200) SBTL 3 XX @/FOR (CHARACTERS) SBTL CA/AT 10) PROGRAMMING OF PLU/SUBDEPT 0 XX: FUNCTION CODE (Refer to the FUNCTION LIST) XXXX PLU CODE PLU Y SBTL CA/AT (CHARACTERS): CHARACTER (Max. 8 Characters) Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER BY NUMERIC KEYS IS AS FOLLOWS: (Code entry) XXXX: PLU CODE (1 to 1200) Y: 0 = SUBDEPT, 1 = PLU YYY 3 [00] KEY MRS = 1 (PLU type) YYY: CHARACTER CODE (3 DIGITS) (or [000] KEY ACCORDING TO PGM PRESET) MRS = Refer to the following table XE-A21S PROGRAM MODE 2–5 ■ FUNCTION LIST F-NO. 1 F-NO. FUNCTION (-) DEFAULT 12 3 4 56 7 8 (-) 2 %1 %1 3 %2 %2 4 NET1 NET1 5 TAXABLE1 ST TAX1 ST 6 GROSS TAX1 GRS TAX1 7 REFUND TAX1 RFD TAX1 8 NET TAX1 TAX1 9 EXEMPT TAX1 TX1 EXPT DEFAULT 12 3 45 6 7 8 FUNCTION 49 CONVERSION (OPEN RATE) CONV 2 50 CASH IN DRAWER ****C ID 51 CASH+CHECK IN DRAWER CA+ CH ID 52 CHECK CHANGE CHK / CG 53 VAT EXEMPT (For DOUGHNUT TAX Type1) VAT 54 (+) DEPT TOTAL *DEPT TL 55 (-) DEPT TOTAL DEPT ( - ) EXPT 56 SUBTOTAL SUBTOTAL 57 MDS SBTL MDSE ST 58 TOTAL ***TOTAL CHANGE CHANGE 10 TAXABLE2 ST TAX2 ST 59 11 GROSS TAX2 GRS TAX2 60 ITEMS ITEMS 61 DEPT. REPO. TITLE DEPT 12 REFUND TAX2 RFD TAX2 13 NET TAX2 TAX2 62 PLU REPO. TITLE PLU 63 TRANS. REPO. TITLE TRANS. 64 CLERK REPO. TITLE CLERK HOURLY REPO. TITLE HOURLY 14 EXEMPT TAX2 TX2 EXPT 15 TAXABLE3 ST TAX3 ST 16 GROSS TAX3 GRS TAX3 65 17 REFUND TAX3 RFD TAX3 66 NON ADD CODE TEXT # 67 COPY RECEIPT TITLE COPY 18 NET TAX3 TAX3 19 EXEMPT TAX3 TX3 EXPT 68 EJ REPORT TITLE EJ 69 EJ REPORT END TITLE EJ 20 TAXABLE4 ST TAX4 ST 21 GROSS TAX4 GRS TAX4 22 REFUND TAX4 RFD TAX4 23 NET TAX4 TAX4 24 EXEMPT TAX4 TX4 EXPT END 14) PROGRAMMING OF LOGO TEXT NO CHANGE 25 GROSS M-TAX GRS MTAX 26 REFUND M-TAX RFD MTAX 27 NET M-TAX M-TAX 28 NON GST SUBTOTAL GST EXPT 29 PST TOTAL PST TTL 30 GST TOTAL GST TTL 31 TOTAL TAX TTL TAX 32 NET without TAX NET 33 NET2 NET2 34 REFUND REFUND 35 VOID VOID 36 VOID MODE VO I D 37 MANAGER VOID MGR VD 38 SBTL VOID SBTL VD SBTL 4 @/FOR X LINE NO. (CHARACTERS) NO SALE NO S ALE 40 RA ***RA 41 PO ***PO 42 CUSTOMER TRA NS CT 43 NET3 (SALES) NET3 44 CASH CASH 45 CHECK CHECK 46 GROSS CHARGE1 CHARGE 47 REFUND CHARGE1 CHARGE - 48 CONVERSION (PRESET RATE) CONV 1 XE-A21S CA/AT X: LINE NO. (1 to 6) (CHARACTERS): CHARACTER (Max. 24 Characters) Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER BY NUMERIC KEYS IS AS FOLLOWS: YYY3 [00] KEY YYY : CHARACTER CODE (3 DIGITS) (or [000] KEY ACCORDING TO PGM PRESET) (Sample) 39 SBTL SHARP PRESENTS THE MRS = PROGRAM MODE 2–6 BEST ECR SHARP IS THE BEST 15) PROGRAMMING OF CLERK NAME A: INTERVAL BETWEEN BREAKPOINTS NO CHANGE SBTL 5 @/FOR XX (CHARACTERS) SBTL CA/AT A BELOW 1 DOLLAR 0 1 DOLLAR OR MORE AND LESS THAN 100 DOLLAR 1 B: TAX TABLE No. XX: CLERK NO. (1 to 25) (CHARACTERS): CHARACTER (Max. 8 Characters) Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER BY NUMERIC KEYS IS AS FOLLOWS: B TABLE1 1 TABLE2 2 TABLE3 3 TABLE4 4 TAX RATE : 0.0001 to 99.9999 CYCLE : 0 to 9999 YYY3 [00] KEY INITIAL TAX : 0 to 999 YYY : CHARACTER CODE (3 DIGITS) LOWER TAX LIMIT : 0 to 99999 (or [000] KEY ACCORDING TO PGM PRESET) BREAK POINT : 0 to 99999 MRS = CLERKxx (xx: clerk no.) MRS = NO TAX 16) FOREIGN CURRENCY SYMBOL PROGRAMMING 18) TAX RATE PROGRAMMING NO CHANGE SBTL 6 SBTL (CHARACTERS) (Inhibition programming) CA/AT (CHARACTERS): CHARACTER (Max. 4 Characters) 0 SBTL Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER BY NUMERIC KEYS IS AS FOLLOWS: 9 @/FOR A @/FOR TAX NO. xxx.xxxx TAX RATE 0 @/FOR YYY3 [00] KEY xxxxx LOWER TAX LIMIT FOR ADD TAX YYY : CHARACTER CODE (3 DIGITS) (or [000] KEY ACCORDING TO PGM PRESET) MRS = ____ ( _ : space code) SBTL Note: This symbol is printed as the amount of CURRENCY CONVERSION for PRESET RATE only. The amount symbol of CURRENCY CONVERSION for OPEN RATE is not printed. A : TAX 1 PROGRAMMING 1 TAX 2 PROGRAMMING 2 TAX 3 PROGRAMMING 3 TAX 4 PROGRAMMING 4 17) TAX TABLE PROGRAMMING SBTL 8 AB @/FOR xx.xxxx @/FOR DECLARATION OF TAX @/FOR % TAX RATE &SIGN RATE xxx.xxxx = 0.0000 to 100.0000 % TAX RATE (Table Delete programming) LOWER TAX LIMITATION 0.00 to 999.99 (This is invalid in VAT system.) xxx INITIAL TAX MRS = DELETE * xxxx CYCLE @/FOR CA/AT @/FOR 19) RATE HALO PROGRAMMING FOR [%] KEY (Table Delete programming) 0 SBTL xxxxx LOWER TAX LIMIT @/FOR xxxxx @/FOR SBTL 29 @/FOR XXX.XX %n CA/AT CA/AT BREAK POINT XXX.XX: % HALO (0.00 to 100.00) The DECIMAL POINT must be entered for setting the decimal digits. 72 BREAKPOINTS CAN BE PROGRAMMED FOR EACH TAXTABLE. (Case of interval between break point is 1 dollar or more and less than 100 dollar, 36 breakpoints is programmed for each table.) MRS = 100.00 (%) * DEPRESSION OF THE [SBTL] KEY AT THE FOLLOWING POINTS MEANS A TAX TABLE DELETE OPERATION. XE-A21S PROGRAM MODE 2–7 [JOB#5] FUNCTION SELECT 20) [AUTO] KEY PROGRAMMING -- ABCDEFGH -- MRS = 00000001 max 25 A: PO in REG mode AUTO AUTO (Free key) CA/AT Delete A ENABLE 0 DISABLE 1 B: RA in REG mode It must be pushed same [AUTO] key as the programming [AUTO] key at the end of any key entry. Note: [ESC] key cannot be set at [AUTO] key programming. It acts as a key of ERROR ESCAPE function in this programming. B ENABLE 0 DISABLE 1 C: SUBTOTAL VOID in REG mode < [Auto] key function > This machine has [AUTO] key which can be programmed the key-sequence data. When [AUTO] key is depressed, the machine works as same as the programmed key-sequence is entered. Setting mode : PGM 0 DISABLE 1 21) DATE/TIME PROGRAMMING XXXXXXXX DATE 0 DISABLE 1 HHMM TIME 0 DISABLE 1 DATE) XXXXXXXX: YYYYMMDD (Year-month-day) or DDMMYYYY (Day-month-Year) or MMDDYYYY (Month-day-Year) 0 DISABLE 1 0 DISABLE 1 YES (3digits decimal place) 0 (DD: 01 to 31) NO 1 [JOB#6] PRINT FORMAT TIME) HH: Hour (00 to 23) ★ H (MM: 01 to 12) The date entry format complies with the applicable PGM-mode programming. ★ G ENABLE H: FRACTIONAL QUANTITY (YYYY: 2000 to 2099) ★ F ENABLE G: NO SALE in REG mode ★ E ENABLE F: REFUND in REG mode #/SBTL ★ D ENABLE E: DIRECT VOID in REG mode ★ C ENABLE D: INDIRECT VOID in REG mode Executing mode : REG, MGR, OPXZ, X1/Z1, X2/Z2 ★ ★ -- ABCDEFGH -- MRS = 11000011 MM: Minute (00 to 59) A: PRINTER FORMAT Note: It cannot set the non-exist date (like Feb.-30th). MRS = DATE: 01012000 (MM/DD/YYYY) TIME: 0000 PGM/OPXZ/XZ mode 0 @/FOR #/SBTL ★ : Journal Rewind Motor is driven for rewinding reports anytime. B: CONTENTS OF RECEIPT (NK) CA/AT AB : JOB No. NK : PROGRAMMING DATA. (Numeric Keys) [JOB#1] MACHINE No. (6digits) 1 REG/MGR/VOID mode : Journal Rewind Motor is not driven. There are programmed by depressing ST-key after a data that want to set. And it is operated continuously until depressing the TL-key. AB 0 RECEIPT Note: Case of RECEIPT, ECR is controlled the Journal Rewind Motor as below. 22) VARIOUS PROGRAMMING (EACH FUNCTIONS PROGRAMMING) #/SBTL A JOURNAL TOTAL 0 DETAIL 1 C: TIME PRINTING (for all receipt) -- XXXXXX -- B ★ C PRINT 0 NOT PRINT 1 ★ MRS = 000000 D: DATE PRINTING (for all receipt) [JOB#2] CONSECUTIVE No. (4digits) -- XXXX -- MRS = 0000 XE-A21S PROGRAM MODE 2–8 D PRINT 0 NOT PRINT 1 ★ E [JOB#15] FUNCTION SELECT2 PRINT 0 MRS = 000000000 NOT PRINT 1 E: CONSECUTIVE NO. PRINTING ★ -- ABCDEFGH-- A, B, C, D, E, F: Not used (Fixed at “000000”) F: Not used (Fixed at “0”) G: TAX DELETE in REG mode G: ZERO SKIP IN PLU REPORT G NOT SKIP 0 SKIP 1 H: ZERO SKIP IN GENERAL,CLERK,HOURLY 0 SKIP 1 0 DISABLE 1 H: MANUAL TAX in REG mode ★ H NOT SKIP G ENABLE ★ H ENABLE 0 DISABLE 1 ★ [JOB#19] QUANTITY FOR DOUGHNUT EXEMPT -- XX -(for CANADIAN TAX) ★ MRS = 0 [JOB#7] RECEIPT PRINT FORMAT -- ABCDEFGH -- xx : QUANTITY FOR DOUGHNUT TAX EXEMPT = 0 to 99 MRS = 00000000 [JOB#35] ONLINE COMMUNICATION TIME OUT -- XXX -- A, B: Not used (Fixed at “00”) MRS = 007 C: SUBTOTAL PRINT [AT] [SBTL] KEY C NOT PRINT 0 PRINT 1 D: MDSE SBTL PRINT AT [MDSE SBTL] KEY XXX: Time out time (1 to 255 sec) ★ [JOB#50] THERMAL PRINTER DENSITY CONTROL -- XX -MRS = 50 D NOT PRINT 0 PRINT 1 XX: density (00 to 99) ★ 00 : 70 % for standard 50 : 100 % (Standard density) 99 : 130 % for standard E, F, G: Not used (Fixed at “000”) H: PURCHASE NO. PRINTING H PRINT 0 NOT PRINT 1 [JOB#61] OTHERS1 PROGRAMMING ★ -- ABCDEFGH -- MRS = 00100002 A, B: Not used (Fixed at “00”) [JOB#10] POWER SAVING C: Programming of MINUS dept/PLU -- YXXX -- MRS = 0030 Y: POWER SAVING function when a time is displayed Yes (Enable) 1 ★ GRAPHIC LOGO ONLY 1 GRAPHIC LOGO AND 3-LINE FOOTER 2 6-LINE HEADER 3 GRAPHIC LOGO AND 3-LINE HEADER 4 3-LINE HEADER AND 3-LINE FOOTER 5 1 Disregarding 2 0 1 F: Time format F XE-A21S 12hour 0 24hour 1 G: Date format ★ 2–9 ★ ★ G M-D-Y 0 D-M-Y 1 Y-M-D 2 H: TAB H 0 0 1 1 2 2 3 3 PROGRAM MODE ★ E [000] key A 0 0 Raising to unit [00] key MRS = 1 3-LINE HEADER INSTEAD OF GRAPHIC LOGO D Round off (4-DOWN, 5-UP) E: [00] key or [000] key selection for [00] key position -- A -- A: LOGO MESSAGE CONTROL 1 D: Fractional treatment ★ XXX: POWER SAVING TIME to POWER OFF = 001 to 254 (minutes) or 999 (Inhibit) [JOB#11] LOGO PRINTING 0 Enable Y 0 No (Disable) C Disable ★ ★ [JOB#62] OTHERS2 PROGRAMMING -- ABCDEFGH -- F: Subtotal entry before tendering MRS = 00000000 A: Not used (Fixed at “0”) B: ERROR BEEP for missoperation LOCK ERROR MISSOPERATION C: Key catch sound Yes No D: Buffered Keyboard 1 1 0 1 0 No 1 0 No 1 H: Addition to the hourly total in VOID MODE ★ 0 Yes 1 ★ ★ 0 No 1 ★ A Yes 0 No 1 ★ B Yes 0 No 1 ★ C Yes 0 No 1 ★ D Yes 0 No 1 ★ 0 Enable 1 0 Disable 1 ★ 0 Yes 1 ★ ★ 0 Disable 1 1 0 No 1 0 Yes 1 XE-A21S PROGRAM MODE 2 – 10 ★ H Enable 0 Disable 1 -- ABCDEFGH -- A, B, C, D, E, F, G, H: Not used (Fixed at “00000000”) ★ ★ G No MRS = 00000000 ★ ★ F Yes [JOB#65] OTHERS5 PROGRAMMING E Enable 0 No H: OP X/Z report D No Yes G: Reset GT1,2,3 at the general Z1 report C Enable E F: Printing of DATA on PLU resetting report B Disable E: Entry that causes the merchandise SUBTOTAL to be smaller than zero. 1 E: Printing of Z counter on Z report ★ A Yes D: Copy Receipt 0 Enable D: Printing of Training GT on Z report MRS = 01010001 C: NON-ADD code entry ★ H Disable C: Printing of GT3 on Z report [JOB#63] OTHERS3 PROGRAMMING -- ABCDEFGH -- B: NO SALE after non-add code entry 1 H No A: Receipting at the time of NO SALE 0 Compulsory B: Printing of GT2 on Z report G Yes G Noncompulsory MRS = 00000000 A: Printing of GT1 on Z report F Yes G: Printing of VOID MODE in Z1 report ★ E Disable ★ [JOB#64] OTHERS4 PROGRAMMING -- ABCDEFGH -- D Enable F: Printing of VOID MODE in Z2 report ★ 0 1 1 H: Direct non-tender finalization after tendering C No E: VOID mode ★ 0 0 0 Compulsory G: Subtotal entry before direct non-tender finalization B Yes F Noncompulsory ★ [JOB#66] OTHERS6 PROGRAMMING -- ABCDEFGH -- D: EJ print and clear at general Z1 report MRS = 10001100 A: AFTER-TRANSACTION RECEIPT A TOTAL ONLY 0 DETAILS 1 B: AMOUNT PRINTING WHEN PLU UNIT PRICE IS 0 B No 0 Yes 1 C: CONVERSION SBTL PRINTING OF NATIVE SBTL Yes 1 ★ 0 Header information only 1 E 0 Yes (Small size) 1 F: Compression print on journal at REG/MGR/ VOID mode ★ 0 TOTAL 1 0 Yes (Small size) 1 ★ Note: This selection is valid only when “PRINTING FORMAT” is set as “JOURNAL”. This selection is not valid for the printing data of EJ report. It is provided another selection job for EJ. G: Logo Text Print on Journal 0 Yes 1 0 Yes (Small size) 1 H Continue (No warning) 0 Warning (near full warning) 1 Lock (with near full warning) 2 F: TAX PRINTING WHEN TAXABLE SUBTOTAL IS ZERO ★ H ALL RECEIPTS 0 ON SELECTED FUNCTION KEY AT THE TIME OF FINALIZATION 1 ★ F No 0 Yes 1 0 No 1 MRS = 00000000 MRS = 00000000 A, B, C, D, E, F, G, H: Not used (Fixed at “00000000”) A: SPLIT PRICING COUNTING -- ABCDEFGH -- A, B: Not used (Fixed at “00”) 0 1 0 PACKAGE 1 ★ B MULTIPLICATION ONLY 0 SPLIT PRICING & MULTIPLICATION 1 ★ C, D: Not used (Fixed at “00”) C Enable A QUANTITY B: MULTIPLICATION ENTRY SYSTEM MRS = 00100011 Disable ★ H: Not used (Fixed at “0”) [JOB#70] OTHERS10 PROGRAMMING -- ABCDEFGH -- C: Temporary journal printing function of transaction ★ G Yes [JOB#67] OTHERS7 PROGRAMMING -- ABCDEFGH -- [JOB#68] OTHERS8 PROGRAMMING ★ MRS = 00000000 A, B, C, D, E: Not used (Fixed at “00000”) G: TAX PRINTING WHEN TAX IS ZERO H: FOOTER PRINT CONTROL ★ [JOB#69] OTHERS9 PROGRAMMING -- ABCDEFGH -- G No ★ G No (Normal size) H: Action when EJ file is full F No (Normal size) ★ F DETAIL G: Compression print for EJ report D: Not used (Fixed at “0”) No (Normal size) E DETAIL F: REG/MRG/VOID operation records in EJ C 1 E: Compression print on journal at PGM/XZ mode ★ Note: It is not effected for PGM reading and XZ reports. PGM reading and XZ reports are always treatment as “HEADRER ONLY”. ★ 0 No 0 Yes E: PGM mode programming operation records in EJ ★ D No E: TAX PRINTING WHEN GST is VAT ★ Note: It is a function to print one transaction data which is not finalized (during a transaction) when a transaction is operated at “RECEIPT OFF”. It is available only at “RECEIPT PRINTER TYPE”. 0 No 1 F: GST EXEMPT on X/Z 0 NOT PRINTED 1 AUTO TAX = 00 CANADA TAX (GST TYPE nn) = 01 to 11 PROGRAM MODE 2 – 11 ★ F PRINTED GH: TAX SYSTEM = 00 to 11 XE-A21S E Yes ★ [JOB#71] GT2 PROGRAMMING -- XXXXXXXXXXXXX -- 24) TRAINING MODE TEXT PROGRAMMING MRS = 0000000000000 SBTL XXXXXXXXXXXXX : GT (13digits) 87 SBTL (CHARACTERS) CA/AT (CHARACTERS): CHARACTER (Max. 8 characters) [JOB#72] GT3 PROGRAMMING -- XXXXXXXXXXXXX -- Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER BY NUMERIC KEYS IS AS FOLLOWS: MRS = 0000000000000 XXXXXXXXXXXXX : GT (13digits) [JOB#76] GENERAL Z1 RESET REPORT COUNTER -- XXXX -- YYY 3 [00] KEY YYY : CHARACTER CODE (3 DIGITS) (or [000] KEY ACCORDING TO PGM PRESET) MRS = 0000 XXXX : RESET COUNTER (4digits) MRS = TRAINING [JOB#77] GENERAL Z2 RESET REPORT COUNTER -- XXXX -- MRS = 0000 25) TEXT CHANGING (TO DEFAULT TEXT) XXXX : RESET COUNTER (4digits) 0 [JOB#86] TRAINING CLERK PROGRAMMING SBTL -- XX -- MRS = 0 CA/AT When this job is executed, below texts are set as default data. NO CHANGE (CHARACTERS) X MRS = 0 23) DOMESTIC CURRENCY SYMBOL PROGRAMMING 85 @/FOR X: 0 = English text 3 = Spanish text X : CLERK No. = 0 (INHIBIT), 1 to 25 SBTL 88 SBTL (a) Function text (b) Each message text (LOGO, etc..) CA/AT (CHARACTERS): CHARACTER (Max. 4 Characters) Characters can be entered by using the character layout on keyboard or using numeric keys on keyboard. THE KEY ENTRY SEQUENCE FOR ENTERING ONE CHARACTER BY NUMERIC KEYS IS AS FOLLOWS: HEADER 05/02/2006 12:34PM YYY 3 [00] KEY YYY : CHARACTER CODE (3 DIGITS) (or [000] KEY ACCORDING TO PGM PRESET) 123456#1234 MRS = ___$ ( _ : space code) #88 01 BETTY___ *PGM* DATE/TIME/CLERK NO MACHINE NO. /CC-NO. /CLERK NAME MODE TITLE 0 LANGUAGE MODE This symbol is printed with (+) amount of domestic currency. The programmed characters is printed at left side of amount. Ex) Case of “ US$ ”: | DEPT.01 US$1.00 | 2 Programmed symbol 26) RESETTING OF ALL COUNTER AND TOTALIZER If some space characters are programmed at the left side of symbol (like “ $”), they are not counted as the number of character of the currency symbol. (In case of “ US$”, the number of character is 3.) SBTL 89 @/FOR CA/TL All counter, totalizer, EJ data all GTs, and all Z counter are reset. Ex) Case of “ US$”: (The currency symbol means “US$”) |AAAADEPARTMENT01 US$10000.00 | 2 Programmed symbol HEADER 05/02/2006 12:34PM 123456#1234 XE-A21S DATE/TIME/CLERK NO MACHINE NO. /CC-NO. /CLERK NAME *PGM* MODE TITLE #89 JOB# PROGRAM MODE 2 – 12 01 BETTY___ 27) CHANGING MEMORY TYPE (EJ RECORD AND PLU RECORD) SBTL 90 @/FOR (*1) When [SBTL] key is pushed, ECR prints the confirmation message at “RECEIPT” (not print at JOURNAL) and enforces to select either executing or canceling this job. The buffered keys are cleared. X CA/AT (*2) “1” is a keyword to execute this job. X : 0 = TYPE1 (EJ: 2000 records and PLU 1200 records) 1 = TYPE2 (EJ: 3000 records and PLU 210 records) (*3) If the MODE SWITCH is turned to another mode from PGM position or the AC POWER is off when job is executed, the job is cancelled. MRS = 0 Note: If AC POWER is off when ECR accesses SD CRAD, the contents in SD CARD may be broken. When this job is executed, EJ records are deleted and PLU records are set the default data after deleted all records even if same memory type is entered. 123456#1234 01 BETTY___ *PGM* DATE/TIME/CLERK NO MACHINE NO. /CC-NO. /CLERK NAME MODE TITLE #90 0 [JOB#140] Format SD CARD This job formats SD card. (It deletes all data on SD card.) After formatting card, the folder \SHARP\ECRXXX01 is made to a root directory. And then, \ALL, \PROGRAM, \SALES, \EJPRINT, \EJ and \LOGO are made to a folder “\SHARP\ECRXXX01”. The file “SRECORD.REC” is made to both folder “\SHARP\ECRXXX01\SALES” and “\SHARP\ECRXXX01\EJ” and it is set the default data. Notes: • All the data currently written in SD card is erased. HEADER 05/02/2006 12:34PM The action of each job is as below. MEMORY TYPE (0: TYPE1, 1: TYPE2) • The file “SRECORD.REC” is used for control the structure under each folder.Any users dose not need to concern its contents. [JOB#141] Programming data saving to SD CARD 28) MAXIMUM NUMBER OF DEPARTMENTT SBTL 95 @/FOR XX [JOB#147] Programming Data loading from SD CARD CA/AT The below data is saved or loaded. Files are set in the folder for “Programming Data”. XX : Max Number of DEPARTMENT This job is used for the limitation of below functions. File Name (1) Programming for the department code over the maximum number of department. File/Table No. (*1) Field (*1) 1 Date and Time mtimtbl D0 2 Department deptdata 01 B000 (Label, Preset, Price, Text) 3 PLU pludata 11 B000 (Label, Preset, Price, Text) 4 Function programming FuncText A4 Mfunctbl D8 5 Tax Table and Rate mtaxtbl D7 29) SD CARD FUNCTION [Key Sequence of SD Jobs] 6 Logo message mlgxtbl D2 7 Clerk CsrData 51 8 Others Programming mopttbl D1 (2) Registration for the department code over the maximum number of department. (3) Registration for the PLU that is associated to department over the maximum number of department. (4) Printing for the department data over the maximum number of department at PGM READING and XZ REPORTS. MRS = 99 (*1) (*2) SBTL xxx @/FOR SBTL 1 CA/AT : Execute operation (*3) CL : Cancel All fields (*1) The contents of each file are same as the communication data of “ONLINE FUNCTION”. Details of “File No.” and “Table No.” are described in “ONLINE SPECIFICATION”. All data are converted to use at “Customer Support Tool” software on PC. Notes: • If there is data of the same file name, the message of confirmation does not display. Data is overwritten if there is data of the same file name. xxx : JOB code 140 : Format SD CARD 141 : Save Programming Data (ECR 3 SD) 144 : Save All RAM Data (ECR 3 SD) 145 : Load Graphic Logo Data (ECR 1 SD) • Each files are used only for the “Customer Support Tool” software on PC. Any users dose not need to concern its contents. 147 : Load Programming Data (ECR 1 SD) 148 : Load All RAM Data (ECR 1 SD) XE-A21S PROGRAM MODE 2 – 13 [JOB#145] Graphic logo data loading [JOB#144] All Data Saving The below data is loaded. Files are set in the folder for “LOGO Data”. [JOB#148] All Data Loading File Name 1 Graphic LOGO LOGO File/Table No. (*1) Notes: • In case of “DATA SAVING”, the message of confirmation for overwritten the file on SD Card does not display. Data is overwritten if there is data of the same file name. Field (*1) E0 • In case of “DATA LOADING”, the condition of ECR will return to past condition. However, the message of confirmation for overwritten does not display. (*1) The contents of each file are same as the communication data of “ONLINE FUNCTION”. Details of “File No.” and “Table No.” are described in “ONLINE SPECIFICATION”. All data are converted to use at “Customer Support Tool” software on PC. The below data is saved or loaded. Files are set in the folder for “ALL RAM BACKUP”. Note: Files are created only for the “Customer Support Tool” software on PC. Any users dose not need to concern its contents. File Name 1 All RAM data All Note: Each files are used only for the purpose of DATA BACKUP at ECR. Any users dose not need to concern its contents. ■ DISPLAY AND PRINT: Key Display Print 1 2 3 4 5 6 7 8 9 0 [STBL] P 141 P 1 4 1 [@/FOR] P 1 4 1 [SBTL] P - NOTE 123456789012345678901234 (PRE-PRINT HEADDER) !!!!!!!!!!!!!!!!!!!!!!!! YOU SELECT SD CARD JOB PUSH [1]-KEY to EXECUTE PUSH [CL]-KEY to CANCEL !!!!!!!!!!!!!!!!!!!!!!!! Don't turn the mode key while executing a job. !!!!!!!!!!!!!!!!!!!!!!!! (Issuing Receipt) [1] P [CA/AT] S d- AC C E S S . The buffered keys are cleared and the message is printed on “receipt” only. (It is not print on “journal” and “EJ”.) MESSAGE : MAX 8-lines (The message is fixed in ROM.) (Not count up CC# at this time.) 1 (Count up CC#.) DISPLAY : “.” is blinking while executing job. HEADER 05/02/2006 12:34PM 01 123456#1234 BETTY___ PRINT *PGM* #141 (SD ACCESS) S d- AC C E S S . Case of NORMAL END 0. 0 0 DISPLAY: “.” is blinking while executing job. PRINT PRINT : (NON) DISPLAY: (INITIAL) PRINT : STATUS is printed (The message is fixed in ROM.) ***NORMAL END (Issuing Receipt) Case of ERROR END E - S d - 0 1 SD ERROR 01 (Issuing Receipt) Cas e of CHANGING MODE KEY (to cancel) Case of POWER OFF 0. 0 0 SD CANCELED (Issuing Receipt) E - S d - P. O F F : JOB HEADDER is printed. And job code is printed. (Job code is printed only at SD jobs) POWER OFF ERROR AT THE DEVICE CONTROL SET DATA&TIME AGAIN (Issuing Receipt) XE-A21S PROGRAM MODE 2 – 14 DISPLAY: ERROR CODE (2-digits) PRINT : SD ERROR MESSAGE and ERROR CODE (The message is fixed in ROM.) DISPLAY: (INITIAL) PRINT : SD CANCEL MESSAGE (The message is fixed in ROM.) DISPLAY: ERROR MESSAGE PRINT : MESSAGE of POWER OFF (The message is fixed in ROM.) 3. CHARACTER ASSIGNMENT METHOD ■ PROGRAMMING KEY LAYOUT Note: The small characters on the bottom or lower right in each key indications or characters which can be used for character entries for text programming. ■ THE METHOD OF CHARACTER ENTRY AT TEXT PROGRAMMING The character can be entered by using character key or character code. When the character can be entered in the text programming, the key layout is changed from “Function and [DEPT] key layout” to “CHARACTER KEY LAYOUT”. In “CHARACTER KEY LAYOUT”, any key except the Numeric keys and [CL], [SBTL], [CA/AT] are assigned either the character or the control key for character entry. Any character can be entered by following method. By character key: SHIFT (CHARACTER KEY) : Characters on Character key layout. NUMBER (NUMERIC KEY) : Numeric character ("0"), "1", . . . , "9") By Numeric key (Character Code) : xxx [00] xxx : Character Code (The list of Control Key) Key SHIFT Action Entry to shift the following character key. (ex. [SHIFT] 3 [A] : Enter the character “a”.) NUMBER Entry the following numeric key as the number character. (ex. [NUMBER] 3 [1] : Enter the character “1”.) (DC) Double size character: Change the following character to the double size character. BS Back Space : Delete the last character. The status of [SHIFT], [NUMBER] and [DC] are keeping until pushing same control key in each text entry. (STAY DOWN type) And the corresponding indication is lighted up on the display while their status is “on”. (Example) [SHIFT] 3 [A] [B] [C] 3 [SHIFT] 3 [A] [B] [C] : Text “abcABC”. [NUMBER] 3 [1] [2] [3] 3 [NUMBER] 3 [1] [2] [3] : Text “123” and numeric number 123. [DC] 3 [A] [B] [C] 3 [DC] 3 [A] [B] [C] : Text “ABCABC”. XE-A21S PROGRAM MODE 2 – 15 Printer CHARACTER CODE CHARACTER CODE CHARACTER CODE CHARACTER CODE 001 á 049 1 098 b 147 ù 196 002 â 050 2 099 c 148 à 197 003 ê 051 3 100 d 149 Æ 198 004 î 052 4 101 e 150 φ 199 ì 053 5 102 f 151 Å 200 í 054 6 103 g 152 ¤ 201 007 ô 055 7 104 h 153 é 202 008 ó 056 8 105 i 154 è 203 û 057 9 106 j 155 Pt 204 ú 058 : 107 k 156 ¡ 205 059 ; 108 l 157 Ñ 206 060 < 109 m 158 Õ 207 061 = 110 n 159 £ 208 062 > 111 o 160 ¥ 209 063 ? 112 p 161 210 Λ 064 @ 113 q 162 211 017 Ψ 065 A 114 r 163 212 018 Γ 066 B 115 s 164 019 .. 067 C 116 t 165 Ω D 117 u 166 T 020 068 ∆ E 118 v 167 T 021 069 Θ F 119 w 168 T 022 070 023 Ξ CODE 005 006 009 010 011 œ 012 013 ú 014 015 016 ó 024 Π 025 Σ 026 Υ 027 Φ 028 029 Ú 030 CHARACTER P š 213 . 071 G 120 x 169 T 072 H 121 y 170 1 073 I 122 z 171 1 074 J 123 { 172 1 075 K 124 | 173 2 076 L 125 } 174 2 077 M 126 ß 175 3 078 N 127 079 O 128 !! 177 080 P 129 1 081 Q 130 082 R 083 214 1 215 2 216 3 217 4 218 2 219 3 220 4 221 3 222 4 223 4 224 176 * 225 § 226 Ø 178 227 ^ 2 179 228 2 131 3 180 A 229 ] S 132 4 181 a 230 [ 182 E 231 Á 031 Ó 032 (Space) 033 ! 034 " 035 # 084 T 133 1 036 $ 085 U 134 F T 183 e 232 ä 037 % 086 V 135 1 184 I 233 ö 038 & 087 W 136 3 185 i 234 ü 039 ' 088 X 137 p 186 U 235 æ 040 ( 089 Y 138 p 187 u 236 å 041 ) 090 Z 139 d 188 237 É 042 * 091 Ä 140 e 189 238 ñ 043 + 092 Ö 141 F 190 044 , 093 Ü 142 T 191 045 – 094 ^ 143 4 192 046 . 095 _ 144 ç 193 047 / 096 145 O 194 048 0 097 146 ¿ 195 253 (DC) a /2 Note: The character of this table is for reference. Please see actual display. (DC) : Double Code : ECR Control Character (Not used for text) XE-A21S PROGRAM MODE 2 – 16 Š 4. HELP FUNCTION This function prints guidance messages of main cash register functions by pushing the HELP key. If you push a number key and the HELP key following the guidance messages, more detailed guidance messages will be printed. If [HELP] key is pressed on the ECR, the following receipt is printed. HEADER [PURPOSE] The aim is to be able to easily program the register by printing the guidance messages. DATE/TIME/CLERK NO MACHINE NO. /CC-NO. /CLERK NAME HELP MENU MODE TITLE 1-[HELP]: DATE/TIME 2-[HELP]: TAX 3-[HELP]: DEPARTMENT 4-[HELP]: SALES Z REPORT 5-[HELP]: LOGO 6-[HELP]: RECEIPT 7-[HELP]: P IN DISPLAY 8-[HELP]: ERROR 32 9-[HELP]: SD CARD 10-[HELP]: PC S/W INSTALL -----------------------OTHER ISSUE: PLEASE CALL 1-800-BE-SHARP [PROGRAMMING] (PGM-mode) Follow the setup features below for the desired HELP printing settings. JOB#6-A 05/02/2006 12:34PM 01 123456#1234 BETTY___ : Printer format receipt/journal. JOB#66-E : Compression print on journal at PGM/XZ mode Small size/ Normal size. JOB#66-F : Compression print on journal at REG/MGR/VOID mode Small size/Normal size. (REG/MGR-mode) Even if ECR is in a receipt-off state, HELP printing is executed. 1-[HELP]: DATE/TIME (Other) HELP printing is written in electronic journal. HEADER [OPERATION] 1. Available Mode of Help function PGM, VOID, O/P X/Z, REG, MGR, X1/Z1, X2/Z2 DATE/TIME/CLERK NO MACHINE NO./CC-NO./CLERK NAME 1 DATE/TIME SETUP MODE TITLE (PGM MODE) DATE:XXXXXXXX-[SBTL] YYYYMMDD OR DDMMYYYY OR MMDDYYYY(DEFAULT) TIME:HHMM-[SBTL] (0000-2359) EX) 08/01/2006 PM4:30 (DATE FORMAT=M-D-Y) 08012006-[SBTL] 1630-[SBTL] 2. The proper timing of when the HELP function will work is when the transaction is finalized, not during the transaction operation. Key operating sequences Help Menu XX 05/02/2006 12:34PM 01 123456#1234 BETTY___ HELP Help No. key No. [HELP] 1 Date/Time setup Print menu 2 Rate of TAX setup 3 Department setup 4 Sales Z report 5 Logo setting 6 Receipt issue 7 What is P in Display 8 What is ERROR 32 9 SD card command 10 Install PC software XE-A21S PROGRAM MODE 2 – 17 2-[HELP]: TAX 4-[HELP]: SALES Z REPORT HEADER HEADER 05/02/2006 12:34PM 01 123456#1234 BETTY___ DATE/TIME/CLERK NO MACHINE NO. /CC-NO. /CLERK NAME 05/02/2006 12:34PM 01 123456#1234 BETTY___ DATE/TIME/CLERK NO MACHINE NO./CC-NO./CLERK NAME 2 TAX RATE SETUP MODE TITLE 4 SALES Z REPORT MODE TITLE (PGM MODE) [SBTL]-9-[@]-N-[@]-R[@]-Q-[SBTL]-[CA] N:TAX NUMBER (1-4) R:RATE(0.0000-100.0000%) Q:MIN. TAXABLE AMOUNT (0.00-999.99) EX) TAX1(RATE=6.25%), MIN. AMT=$3.00 [SBTL]-9-[@]-1-[@]-6.25 -[@]-300-[SBTL]-[CA] SALES Z REPORT SHOWS THE DAILY/ PERIODIC SALES 1. DAILY Z REPORT (X1/Z1 MODE) [.]-[CA]: GENERAL [.]-[PLU]: PLU [.]-[CLK#]: CLERK [.]-[SBTL]: HOURLY 2. PERIODIC Z REPORT (X2/Z2 MODE) [.]-[CA]: GENERAL 5-[HELP]: LOGO 3-[HELP]: DEPARTMENT HEADER HEADER 05/02/2006 12:34PM 01 123456#1234 BETTY___ DATE/TIME/CLERK NO MACHINE NO./CC-NO./CLERK NAME 3 DEPARTMENT PRICE&TEXT MODE TITLE 05/02/2006 12:34PM 01 123456#1234 BETTY___ DATE/TIME/CLERK NO MACHINE NO. /CC-NO. /CLERK NAME 5 LOGO SETTING MODE TITLE (PGM MODE) 1)LOGO FORMAT [SBTL]-11-[@]-A-[SBTL][CA] A=0:3LINE HEADER 1:GRAPHIC LOGO ONLY 2:GRAPHIC+3LINE FOOTER 3:6LINE HEADER 4:GRAPHIC+3LINE HEADER 5:3LINE HEADER/FOOTER 2)LOGO TEXT [SBTL]-4-[.]-L-[@](TEXT)-[SBTL]-[CA] L:LINE NUMBER(1-6) TEXT CAN BE ENTERED BY USING THE CHARACTER LAYOUT ON KEYBOARD OR NUMERIC KEY ON KEYBOARD. 3)GRAPHIC LOGO PLEASE REFER TO CUSTOMER SUPPORT TOOL (PGM MODE) 1)PRICE XX-[DEPT#]-YYYYYY[SBTL]-[CA] XX:DEPARTMENT CODE(1-99) YYYYYY:UNIT PRICE (MAX.6DIGITS) 2)TEXT [SBTL]-1-[.]-XX-[DEPT#](TEXT)-[SBTL]-[CA] XX:DEPT CODE(1-99) TEXT CAN BE ENTERED BY USING THE CHARACTER LAYOUT ON KEYBOARD OR NUMERIC KEY ON KEYBOARD. XE-A21S PROGRAM MODE 2 – 18 6-[HELP]: RECEIPT 9-[HELP]: SD CARD HEADER HEADER 05/02/2006 12:34PM 01 123456#1234 BETTY___ DATE/TIME/CLERK NO MACHINE NO./CC-NO./CLERK NAME 05/02/2006 12:34PM 01 123456#1234 BETTY___ DATE/TIME/CLERK NO MACHINE NO./CC-NO./CLERK NAME 6 RECEIPT ISSUE MODE TITLE 9 SD CARD COMMAND MODE TITLE WHETHER ISSUE RECEIPT OR NOT CAN BE CHANGED BY DEPRESSING [RCPT] KEY IF THE INDICATOR "_" APPEARS ON DISPLAY, RECEIPT IS NOT ISSUED, IN THIS CASE, DEPRESSING [RCPT] KEY WILL ENABLE RECEIPT PRINT AGAIN (PGM MODE) [SBTL]-XXX-[@]-[SBTL] XXX= 140:FORMAT 141:SAVE PROGRAMMING 144:SAVE ALL RAM 145:LOAD GRAPHIC LOGO 147:LOAD PROGRAMMING 148:LOAD ALL RAM (X1/Z1 MODE) SAVE SALES DATA 650-[.]-[@]-[SBTL] SAVE AND CLEAR EJ DATA 750-[.]-[@]-[SBTL] PRINT EJ DATA ON SD 740-[@]-[SBTL] 7-[HELP]: P IN DISPLAY 10-[HELP]: PC S/W INSTALL HEADER 05/02/2006 12:34PM 01 123456#1234 BETTY___ DATE/TIME/CLERK NO MACHINE NO./CC-NO./CLERK NAME 7 WHAT IS P IN DISPLAY MODE TITLE HEADER [ERROR STATUS] PAPER EMPTY [RESOLUTION] INSERT NEW ROLL PAPER HEADER DATE/TIME/CLERK NO MACHINE NO./CC-NO./CLERK NAME 8 WHAT IS ERROR 32 MODE TITLE DATE/TIME/CLERK NO MACHINE NO./CC-NO./CLERK NAME 10 INSTALL PC SOFTWARE MODE TITLE 1.INSERT CUSTOMER SUPPORT CD IN YOUR PC 2.INSTALLATION PROGRAM RUNS AUTOMATICALLY (FOR USB CONNECTION) 3.AFTER INSTALLATION OF SOFTWARE, -TURN OFF ECR -CONNECT PC AND ECR VIA USB CABLE -TURN ON ECR -SELECT "INSTALL THE SOFTWARE AUTOMATICALLY" AT HARDWARE WIZARD 8-[HELP]: ERROR 32 05/02/2006 12:34PM 01 123456#1234 BETTY 05/02/2006 12:34PM 01 123456#1234 BETTY___ [ERROR STATUS] NO ENTRY OF CLERK CODE [RESOLUTION] ENTER A CLERK CODE EX) ENTRY OF CLERK #1 1-[CLK#] XE-A21S PROGRAM MODE 2 – 19 CHAPTER 3. OP X/Z, X1/Z1, X2/Z2 MODE Roughly speaking, the following sales reports are available: [Purpose] 1) OP X/Z reports (Individual cashier reports) The reports are each used to check sales data. The standard purposes of taking these reports are as follows: 2) X1/Z1 reports (Daily total X and Z reports) 3) X2/Z2 reports (Periodic total X and Z reports) OP X/Z reports : These reports are taken by operators in order to report their own sales data. 4) Flash-read reports (Display sales amount) X1/Z1 reports : These reports are taken by the supervisor or manager in order to check and report daily sales totals at that point. In addition to the above reports that are to be used for program checking are also available. X2/Z2 reports : These reports are taken by the owner or manager in order to check and report periodic (weekly or monthly) totals. Flash-read : These reports are taken by the owner or manager in order to check and display sales totals at that point. [Operation] In the table below those reports marked with a circle “{” can be executed. PRINTING REPORT MODE REPORT NAME KEY ENTRY OPX/Z X X1/Z1 DATA FOR READING X1 Z1 X2 Z2 [CA/AT] { { { { PLU BY RANGE [PLU] { { CRERK (ALL) [CLK]# { { *1 { { *1 GENERAL CRERK (INDIVIDUAL) HOURLY (ALL) Z X2/Z2 { [CLK]# *1, *6 *1, *2 PLU CODE { [#/SBTL] *1, *3 FLASH READING REPORT MODE REPORT NAME KEY ENTRY OPX/Z X DEPARTMENT X1/Z1 Z X1 X2/Z2 Z1 X2 DATA FOR READING Z2 *4 [DPTn] or [SHIFT] 3 [DPTn] or NK 3 [DEPT#] { CID [@/FOR] { *4 PAID TOTAL [CA/AT] { *4 DEPT CODE OTHERS OPERATION MODE REPORT NAME JOB# OPX/Z X2/Z2 Z X1 Z1 { { { EJ report (ALL) 700 { EJ report (Latest 10 records) 710 { MODE: X1/Z1 X X2 { *5, *6 *5, *6 X : Daily operater X report Z : Daily operater Z report X1 : Daily X report Z1 : Daily Z report X2 : Periodic X report Z2 : Periodic Z report (X report): The corresponding data is held in the ECR. (Z report): The corresponding data is cleared in the ECR. XE-A21S DATA FOR READING Z2 OP X/Z, X1/Z1, X2/Z2 MODE 3–1 [Action] • Stop of printing reports (Report cancel function): This ECR has the function of report stopping for PLU report and EJ report. Individual counters for the following Z reports are incremented when those reports are printed. • Printing of GT on X reports: This ECR dose not print any GT on X reports. 1) General daily total report (Z1) 2) General periodic total report (Z2) [Additional function] *1 To read respective reports, it is necessary to follow the procedure below. (1) Overflow mark If the amount or quantity in any totalizer other than GT to be printed on X or Z reports exceeds a programmed limit, the indication mark (overflow mark) is printed for the totalizer concerned. The overflow mark may be printed even if a totalizer does not reach the maximum amount. This occurs, for example, when the amount or quantity in the totalizer gets smaller than the maximum amount due to the entry of a negative amount after the overflowing of the totalizer. This means that when the totalizer overflows once, the overflow mark (for example, “!!”) is printed. Reading (X report) KEY Resetting (Z report) *2 PLU code range can be specified by entering the start and end numbers according to the following procedure. When specifying a single PLU code, the start number has only to be entered. (2) MODE TITLE Each report is printed MODE TITLE at a header of report. The Report Titles are as follows. All Reading XXXX Start No. @/FOR XXXX End No. PLU Resetting *3 To read respective reports, it is necessary to follow the procedure below. The clerk code does not need to enter at the OPX/Z mode. In OPX/Z mode, it is issued the report of the assigned clerk. *4 Reading display only. The displayed amount can be cleared by [CL] key. KEY (Display amount) OPX report *OPX* OPZ report *OPZ* X1 report *X 1* Z1 report *Z 1* X2 report *X 2* Z2 report *Z 2* (3) Report cancel function It can be cancelled by turned the mode switch to MGR position while the data is printed. (In this case, the contents of memory are not cleared.) CL (Display initialize) *5 To read respective contents, it is necessary to follow the procedure below. Reading JOB# : : @/FOR CA/AT * Resetting * * * * 123456789012345678901234 *6 It is able to print and clear the EJ memory at general Z1 report by PGM mode programming. In that case, the contents of EJ memory is printed just after issued general Z1 report. (Issuing general Z1 report 3 Clear daily DEPT & TRANS memory 3 Issuing EJ memory 3 Clear EJ memory) XE-A21S OP X/Z, X1/Z1, X2/Z2 MODE 3–2 1 the report cancel symbol ELECTRONIC JOURNAL REPORT This job is own to print and clear EJ memory in X1/Z1 mode and OPXZ mode. [JOB#650] Sales data saving [Key sequence] All sales data (Daily and term) save in SD card. This job is used for the purpose of using Electric Journal Data at the “Customer Support Tool” software on PC. Maximum 400 times data is kept in SD Card when the SD memory is not full. 1) Reading and resetting of all records: [OPXZ, X1/Z1 mode] (Reading) The action is as below. @/FOR 700 CA/AT Step1) After reading the information of the current sub-folder in “SRECORD.REC” file, ECR creates the new sub-folder under the folder for “Sales Data”. Its folder is named ASCII Character that is indicated the number of sales data in SD Card. (Example: “1”, “2”, “3”,......) (Reseting) 2) Reading of the latest 10 records: [OPXZ, X1/Z1 mode] 710 @/FOR CA/AT Step2) Save the below data in new sub-folder that is created above step. [ACTION] File Name It prints all or parts of printing data in EJ memory. The printing format is same as each operation. It is able to print and clear the EJ memory at general Z1 report by PGM mode programming. In that case, the contents of EJ memory is printed just after issued general Z1 report. (Issuing general Z1 report 3 Clear daily DEPT & TRANS memory 3 Issuing EJ memory 3 Clear EJ memory) D0 2 Department Sales 01 All fields Trans 21 All fields Func Text A4 Hourly 61 All fields 5 Clerk Sales Csr Data 51 All fields Csr Sal 52 All fields 6 PLU Sales Plu 11 All fields, All range1 Spet 3) Create the “STATUS.REC” file in new sub-folder when all files are saved completely. (*1) (*2) xxx @/FOR SBTL 1 yyy xxx: Dept 4 Hourly Sales [Report cancel function] [Key Sequence of SD Jobs] Field (*1) 1 Date and Time mtimtbl (When a job is operated) 3 Transaction Sales It can be cancelled by turned the mode switch to MGR position while EJ data is printed. (In this case, the contents of EJ memory are not cleared.) File/Table No. (*1) CA/AT : Execute operation (*3) CL : Cancel File Name 1 Status information STATUS. REC JOB code Step 4) Update the “SRECORD.REC” file for changing the structure of sub-folder. 650: Save Sales Data (ECR 3 SD) 750: Save and Clear EJ Data (ECR 3 SD) yyy: File Name JOB code 1 Record structure 740: Printing EJ Data on SD (ECR 1 SD) (*1) When [SBTL]-key is pushed, ECR prints the confirmation message at “RECEIPT” (not print at JOURNAL) and enforces to select either executing or canceling this job. The buffered keys are cleared. SRECORD. REC (*1) The contents of each file are same as the communication data of “ONLINE FUNCTION”. Details of “File No.” and “Table No.” are described in “ONLINE SPECIFICATION”. All data are converted to use at “Customer Support Tool” software on PC. (*2) “1” is a keyword to execute this job. Note: Each files are used only for the “Customer Support Tool” software on PC. Any users dose not need to concern its contents. (*3) If the MODE SWITCH is turned to another mode from X1Z1 position or the AC POWER is off when job is executed, the job is cancelled. [JOB#750] Electric Journal Saving and Clearing on memory 750 Note: If AC POWER is off when ECR accesses SD CRAD, the contents in SD CARD may be broken. @/FOR CA/AT Electric journal data is saved in SD card. This job is used for the purpose of using Electric Journal Data at the “Customer Support Tool” software on PC. Maximum 400 times data is kept in SD Card when the SD memory is not full. The action of each job is as below. Note: After saving EJ data, ECR is clear the Electronic Journal memory. XE-A21S OP X/Z, X1/Z1, X2/Z2 MODE 3–3 Step6) Clear EJ DATA on memory at ECR. The action is as below. Step1) Save the below data in the folder for “Electric Journal for printing”. File/Table No. (*1) File Name 1 EJ Data EJFILE (*1) The contents of each file are same as the communication data of “ONLINE FUNCTION”. Details of “File No.” and “Table No.” are described in “ONLINE SPECIFICATION”. All data are converted to use at “Customer Support Tool” software on PC. Field (*1) A0 Notes: • The file in the EJPRINT folder on SD Card is overwritten. The message of confirmation for overwritten the file in the EJPRINT folder on SD Card does not display. Step2) After reading the information of the current sub-folder in “SRECORD.REC” file, ECR creates the new sub-folder under the folder for “Electric Journal Data”. Its folder is named ASCII Character that is indicated the number of sales data in SD Card. (Example: “1”, “2”, “3”,......) • Each files are used only for the “Customer Support Tool” software on PC. Any users dose not need to concern its contents. Step3) Save the below data in new sub-folder that is created above step. File/Table No. (*1) File Name 1 EJ Data EJFILE [JOB#740] Electric journal print Field (*1) ECR prints the below data that is already set in the folder for “EJPRINT Data”. A0 File Name Spet4) Create the “STATUS.REC” file in new sub-folder when all files are saved completely. 1 EJ Data File Name 1 Status information EJFILE Field (*1) A0 (*1) The contents of each file are same as the communication data of “ONLINE FUNCTION”. Details of “File No.” and “Table No.” are described in “ONLINE SPECIFICATION”. All data are converted to use at “Customer Support Tool” software on PC. STATUS. REC Step5) Update the “SRECORD.REC” file for changing the structure of sub-folder. Notes: • It is printed only the newest EJ DATA (That is saved at last by either ECR or PC). File Name 1 Record structure File/Table No. (*1) • Each files are used only for the “Customer Support Tool” software on PC. Any users dose not need to concern its contents. SRECORD .REC ■ DISPLAY AND PRINT: X1/Z1 MODE) JOB ENTRY OPERATION: (Common action for all Jobs) Key Display Print 1 2 3 4 5 6 7 8 9 0 750 [ . ] 7 5 0. [@/FOR] 7 5 0. [SBTL] - [1] NOTE 123456789012345678901234 (PRE-PRINT HEADDER) !!!!!!!!!!!!!!!!!!!!!!!! YOU SELECT SD CARD JOB PUSH [1]-KEY to EXECUTE PUSH [CL]-KEY to CANCEL !!!!!!!!!!!!!!!!!!!!!!!! Don't turn the mode key while executing a job. !!!!!!!!!!!!!!!!!!!!!!!! (Issuing Receipt) The buffered keys are cleared and the message is printed on “receipt” only. (It is not print on “journal” and “EJ”.) MESSAGE: MAX 8-lines (The message is fixed in ROM.) (Not count up CC# at this time.) 1 S d - AC C E S S . [CA/AT] HEADER 05/02/2006 12:34PM 123456#1234 01 BETTY___ *Z1* Case of EJ PRINT: The EJ DATA is printed as same as EJ REPORT (#700) after printing job code. #750 (SD ACCESS) (Count up CC#.) DISPLAY: “ . ” is blinking while executing job. PRINT : JOB HEADDER is printed. And job code is printed. (Job code is printed only at SD jobs) S d - AC C E S S . DISPLAY : “ . ” is blinking while executing job. PRINT : (NON) : : --- Continue to JOB END MESSAGE (NEXT PAGE) XE-A21S OP X/Z, X1/Z1, X2/Z2 MODE 3–4 [JOB END MESSAGE] Case of DATA SAVING (“SALES” or “EJ DATA”): Key Display Print 1 2 3 4 5 6 7 8 9 0 NORMAL END NOTE 123456789012345678901234 0. 0 0 DISPLAY: (INITIAL) PRINT : STATUS is printed (The message is fixed in ROM.) ***NORMAL END (Issuing Receipt) ERROR END E - S d - 0 1 SD ERROR 01 (Issuing Receipt) CANCEL (CHANGING MODE KEY) POWER OFF 0. 0 0 SD CANCELED (Issuing Receipt) E - S d - P. O F F POWER OFF ERROR AT THE DEVICE CONTROL SET DATA&TIME AGAIN DISPLAY: ERROR CODE (2-digits) PRINT : SD ERROR MESSAGE and ERROR CODE (The message is fixed in ROM.) DISPLAY: (INITIAL) PRINT : SD CANCEL MESSAGE (The message is fixed in ROM.) DISPLAY: ERROR MESSAGE PRINT : MESSAGE of POWER OFF (The message is fixed in ROM.) (Issuing Receipt) The messages are printed on both RECEIPT and JOURNAL and recorded in EJ memory. [JOB END MESSAGE] Case of EJ DATA PRINTING: Key Display Print 1 2 3 4 5 6 7 8 9 0 NORMAL END 123456789012345678901234 0. 0 0 (Issuing Receipt) ERROR END E - S d - 0 1 * * * * * * SD ERROR 01 (Issuing Receipt) CANCEL (CHANGING MODE KEY) 0. 0 0 * * * * * * SD CANCEL (Issuing Receipt) POWER OFF NOTE E - S d - P. O F F * * * * * * POWER OFF ERROR AT THE DEVICE CONTROL SET DATA&TIME AGAIN DISPLAY: (INITIAL) PRINT : (NON) DISPLAY : ERROR CODE (2-digits) PRINT : The report cancel symbol, SD ERROR MESSAGE and ERROR CODE (The message is fixed in ROM.) DISPLAY: (INITIAL) PRINT : The report cancel symbol and SD CANCEL MESSAGE (The message is fixed in ROM.) DISPLAY: ERROR MESSAGE PRINT : The report cancel symbol, POWER OFF ERROR MESSAGE and Notes message (The message is fixed in ROM.) (Issuing Receipt) The report cancel symbol is printed on both RECEIPT and JOURNAL, but it is not recorded in EJ memory. The messages except the report cancel symbol are printed on both RECEIPT and JOURNAL and recorded in EJ memory. [ERROR CODE LIST] No. 01 Description SD card is not find 02 SD CARD PROTECT SWITCH is set “PROTECED” 03 SD CARD WRITTING ERROR (Memory is full) (ECR cannot write the data on SD card.) 04 SD CARD READING ERROR (File is nothing) 05 SD CARD READING ERROR (File data is failed) (ECR cannot read the data on SD card.) : 10 <<< Reserved >>> Over limitation of data records (Over max record in sales or EJ data.) : <<< Reserved >>> 99 SD CARD ERROR (Anyhow error except above SD ERROR is occurred when ECR accesses SD Card.) XE-A21S OP X/Z, X1/Z1, X2/Z2 MODE 3–5 COPYRIGHT  2006 BY SHARP CORPORATION All rights reserved. Printed in Japan. No part of this publication may be reproduced, stored in a retrieval system, or transmitted. In any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher. SHARP CORPORATION Information and Communication Systems Group Quality Assurance Department Yamatokoriyama, Nara 639-1186, Japan 2006 November Printed in Japan t