® Proline® Server Cabinets Proline Flotek™ Td (top Ducted) Server Cabinet

   EMBED


Share

Transcript

Networking: Free-Stand Cabinets PROLINE® Server Cabinets Spec-00558 C PH (763) (763) 422-2588 422-2661 FX Networking Free-Stand Cabinets PROLINE® Server Cabinets PROLINE® FLOTEK™ TD (Top Ducted) Server Cabinet •• F ully perforated front door provides unrestricted cold airflow to equipment •• Front sealed 19-in. mounting rails and top/bottom air blocking plates prevent cold air bypass •• Solid rear door directs hot exhaust into chimney to prevent mixing with cold airflow •• Data center efficiency increases when cold and hot airflows are kept separate resulting in higher CRAC temperatures (cold airflow to the equipment) •• Reduces overall energy needs with more efficient cold air delivery to equipment •• Allows increased thermal loads and higher server densities inside cabinet •• Can be used on raised and non-raised floors Specifications •• T op sliding gland plate accommodates cables, cable bundles and pre-terminated patch panels •• Exhaust air deflector routes airflow to chimney to avoid hot spots •• Chimney provided with edge gasket and S-connectors •• Attractive, rigid front door made of aluminum extrusions and formed perforated steel, with more than 60 percent open space for free flow of cool air to equipment •• Front door is left-hinged and reversible •• Front and rear doors have keyed multi-point vault-style latch system and central key lock to ensure security •• Solid rear door is fully gasketed to ensure all hot exhaust is directed to top duct •• Front air dam surrounds mounting rack angles to prevent cold air bypass •• Top and sides are formed steel •• Rack angles have .375-in. spaced square holes per EIA standards Industry Standards Finish EIA 310-D Application PROLINE® FLOTEK™  TD improves equipment efficiency and lowers energy costs by directing hot exhaust from the cabinet up above the plenum or drop ceiling and away from the cold room air. Photo shown with Tool-less (Snap-in) Blanking Panels installed. Order separately. Features •• D  esigned for use with 19-in. rack-mounted servers, blade servers and other equipment •• Adjustable top duct (chimney) is provided in two different standard heights to fit various Data Center ceilings •• Chimney is pre-assembled and shipped inside the cabinet to ease assembly and avoid extra parcels and shipping damage •• S-connectors provided with chimney to facilitate connection to HVAC duct work •• Edge gasket provided with chimney to prevent hot exhaust gas from mixing with cold airflow •• Cabinet is provided with seals and blocking panels to eliminate cold air bypass •• Includes two sets of fully adjustable mounting angles which are RU marked front and back to facilitate assembly •• Open base allows under-floor cable entry RAL 9005 black textured, low-gloss polyester powder paint over pretreated steel. Front door extrusion has a smooth, low-gloss, silver polyester power paint finish. Load Rating Static Load Rating: 2500 lb. (1134 kg) A cabinet has a static load when: •• it is in its final, permanent, fully secured location, and •• its load is uniformly applied to the two sets of rack-mounting angles Never move a cabinet with its maximum static load applied. Contact Hoffman if further information is needed. Accessories 19-in. Rack-Mount Environmental Monitor Cable and PDU Manager Rack- and Panel-Mount Power Distribution Units (PDUs) Screw Packages Tool-less (Snap-in) Blanking Panels for 19-in. Racks Tool-less Shelf Vertical Cable Manager 1 Bulletin: DPVD Standard Product  Catalog Number PSTD20610BM PSTD20610BT PSTD20611BM PSTD20611BT PSTD20612BM PSTD20612BT AxBxC mm 1991 x 608 x 999 1991 x 608 x 999 1991 x 608 x 1099 1991 x 608 x 1099 1991 x 608 x 1199 1991 x 608 x 1199 AxBxC in. 78.37 x 23.94 x 39.34 78.37 x 23.94 x 39.34 78.37 x 23.94 x 43.28 78.37 x 23.94 x 43.28 78.37 x 23.94 x 47.22 78.37 x 23.94 x 47.22 Subject to change without notice H MInimum (mm) 2600 2905 2600 2905 2600 2905 H Minimum (in.) 102.36 114.36 102.36 114.36 102.36 114.36 H Maximum (mm) 3057 3667 3057 3667 3057 3667 PH (763) 422-2661 • FX (763) 422-2588 • hoffmanonline.com H Maximum (in.) 120.36 144.36 120.36 144.36 120.36 144.36 Rack Units 42 42 42 42 42 42 © 2011 Pentair Technical Products Spec-00558 C 1 Networking: Free-Stand Cabinets PROLINE® Server Cabinets Gland Plate Opening (17.80 x 6.00) 452 mm 152 mm) C 1.90 48 mm 16.69 424 mm 21.01 534 mm 2.18 55 mm H C - 5.78 147 mm (Opening) 75.24 1911 mm (Opening) 78.40 1991 mm .36 9 mm C - 2.50 64 mm (Max Outside Distance of Rack Angles) B (SHOWN WITHOUT SIDES) 2 Subject to change without notice PH (763) 422-2661 • FX (763) 422-2588 • hoffmanonline.com © 2011 Pentair Technical Products Spec-00558 C 89049950 Networking: Free-Stand Cabinets PROLINE® Server Cabinets Subject to change without notice PH (763) 422-2661 • FX (763) 422-2588 • hoffmanonline.com © 2011 Pentair Technical Products Spec-00558 C 3 Networking: Free-Stand Cabinets PROLINE® Server Cabinets 4 Subject to change without notice PH (763) 422-2661 • FX (763) 422-2588 • hoffmanonline.com © 2011 Pentair Technical Products Spec-00558 C