Proplus Ako-15640 Quick Connection

   EMBED


Share

Transcript

GB 1564H012 Ed.02 PROPlus AKO-15640 Quick connection Operating as control panel for the Evaporator + Solenoid Application Aimed at installations that do not require control of the Condensing unit, for example, Silensys, Optyma Plus or similar units. Condenser Control ŸSolenoid ŸEvaporator fan ŸElectric defrosting ŸCold room light HIGH pressure controller Solenoid Compressor Configuration Evaporator LOW pressure controller The following parameters must be configured: ŸSet Point: Temperature to control (Set Point). ŸConnected sensors: Probes 1 and 2. Max 15 A 230V 8A 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 L N PE 36 37 38 39 40 41 42 43 PE MODBUS RS-485 PE C NO NC Tr Tr Probe 2 Probe 1 PE ALARM RELAY L N N L 1 16 A 2 L N IMPORTANT: Terminals 1 and 2 must be linked in the FAN EVAPORATOR Silensys(AR) condenser unit. 230Vac Terminals 3 and 4 must be linked in the 4A Optima Plus (S1) condenser unit. For more information, check your condenser unit's manual. AUXILIARY RELAY OUTPUT 230Vac 460W LIQUID SOLENOID VALVE 230Vac LIGHT 230Vac 460W N L DEFROST RESISTOR 230Vac 11A 2500W CONNECT ALL EARTH CONNECTIONS IN THIS TERMINAL Remark: The recommended currents and powers are the maximum working currents and powers. GB 1564H012 Ed.02 Operating as control panel for the Condenser + Evaporator + Solenoid Application Condenser Aimed at installations that need to control the condenser unit and the liquid solenoid valve independently (Pump Down). Allows pressure controller status supervision. Control ŸCondensing unit ŸSolenoid ŸEvaporator fan ŸElectric defrosting ŸCold room light ŸHIGH / LOW Pressure controller HIGH pressure controller Solenoid Compressor Evaporator LOW pressure controller Configuration The following parameters must be configured: ŸSet Point: Temperature to control (Set Point) ŸConnected sensors: Probes 1 and 2 ŸInput 1 configuration (Terminals 25 and 27): Configure as "Low pressure input". ŸInput 1 polarity : Configure according to type of pressure controller used (See attached table). ŸInput 2 configuration (Terminals 26 and 27): Configure according to type of pressure controller used (See attached table). ŸInput 2 polarity : Configure according to type of pressure controller used (See attached table). ŸAux. relay configuration: Configure as "Pump Down". Max 15 A 230V 8A 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 L N PE 36 37 38 39 40 41 42 43 PE MODBUS RS-485 PE C NO NC Tr Tr Probe 2 Probe 1 PE ALARM RELAY L N N L 1 2 16 A FAN EVAPORATOR 230Vac 2.2 A L N N L DEFROST RESISTOR 230Vac 460W 230Vac 70W Option 1: 3 terminal dual pressure-controller 230Vac LIGHT CRANKCASE RESISTOR L N LIQUID SOLENOID VALVE COMPRESSOR 230Vac 11.5A 1,25 CV 230Vac 11A 2500W Option 2: 4 terminal dual pressure-controller CONNECT ALL EARTH CONNECTIONS IN THIS TERMINAL Remark: The recommended currents and powers are the maximum working currents and powers. Option 3: High pressure controller and Low pressure controller 25 26 27 25 26 27 A 25 26 27 HP A C LP HP Input 1 polarity: Normally open Input 2 configuration: Severe external alarm / High pressure controller alarm Input 2 polarity: Normally open HIGH B(2) A(1) LP C(4) A(1) HP Input 1 polarity: Normally open Input 2 configuration: Severe external alarm / High pressure controller alarm Input 2 polarity: Normally open 351564012 REV.01 2015 Input 1 polarity: Normally closed LOW D C LP AKO ELECTROMECÁNICA , S.A.L. Avda. Roquetes, 30-38 08812 • Sant Pere de Ribes. Barcelona • Spain. Tel.: +34 902 333 145 Fax: +34 938 934 054 www.ako.com We reserve the right to supply materials that might vary slightly to those described in our Technical Sheets. Updated information is available on our website.