Preview only show first 10 pages with watermark. For full document please download

Proposed Plan

   EMBED


Share

Transcript

SIGNAGE DETAIL TYPICAL CHOPSTIX ARTWORK NOTES: TYPICAL CHOPSTIX ELEVATION Main Entrance 0 Fire Suppression system handle 4 Pot Bain Marie power required EXTRACTION Elec Fryer - Model DF49 Fryer Single Tank - Single or 3 Phase New 30 min FR Stud Partitions with new FD 30S door and lining with all necessary ironmongery/signage etc. 600 New projecting sign Main Entrance FIXED WHB 980 Stainless Steel Table Stainless Steel Table 750 6 Elec Fryer - 650124/b500 Super East 411 Fryer. 3 Phase supply required. Part Internal Elevation 870 4 500 2630 WHB 4 Pot Bain Marie 30 Extract hood 1500mm o/a Mc to provide adjacent housing for fire suppression system tanks. Extract hood above - dims & route out tba. 725 EXTRACTION 4 Pot Bain Marie power required Front counter Extract hood 2200mm o/a Mc to provide adjacent housing for fire suppression system tanks. SERVICE AREA Drinks Fridge Single Door 2 Menu fitted to front of extract hood. Glass cladding to all visible elevations. Hood to be provided with lip to lower edge for fixing of glass. Projecting Sign: Non illuminated powder coated aluminum backpanel finish. Letters created with green translucent vinyl. (500x600x50mm) 8 FIXED Stainless Steel Table New Signage: Individual LED illuminated letters constructed from opal perspex to approximately 70mm projection finished with green translucent vinyl overlay. Fixed to 80mm non illuminated powder coated aluminum backpanel finished RAL 1033. Entrance 10m Proposed Shopfront Elevation Proposed Ground Floor Plan Main Entrance Main Entrance LEGEND LIGHT D D DESCRIPTION - Ceiling Light 600mm D D D Manual Call Point - Ceiling Vent 600mm LIGHT SP BG B FIRE SUPPRESSION SYSTEM E Shop Floor D LIGHT - Spot Light P - Pendant Light D - Down Lighter SD - Speakers P D EXTRACTION - AC Cassette Air Conditioning Unit 930mmx930mm P D W - WET CHEMICAL FIRE EXTINGUISHER B - FIRE BLANKET - CARBON DIOXIDE FIRE EXTINGUISHER P LIGHT SD - 9 LT. WATER FIRE EXTINGUISHER Pleated Filters Bag Filters Carbon Filters E P B A 20 Princess Way, The Mall Camberley D SPEAKER Alarm Sounder c LEGEND DESCRIPTION SD - Smoke/Heat Detector E - Emergency Light BG - Break Door Glass release Extract Fan EXTRACTION 30 Kitchen SP LIGHT SP SP LIGHT Manual Call Point SD LIGHT E SD - Illuminated Fire Exit sign SP - Alarm Sounder LIGHT s - Manual Call Point W W Proposed Extraction Plan EXISTING & PROPOSED PLAN, PROPOSED SHOPFRONT, EXTRACTION & INVERTED CEILING PLAN & PART INTERNAL ELEVATION - Fire Exit Sign B Silencer E Manual Call Point SP Proposed Inverted Ceiling Plan 30 - 30S Door K.K 1:50 @A1 012.15 01.16 Chopstix Group Cedars House 136 - 144 Golders Green London NW11 8HB B