Transcript
Prices as of April 16, 2014. Check Web site for most current prices.
TTD25 Series Temperature Transmitter
Company Information Drives
Features
Soft Starters
Agency Approvals
• High accuracy 2-wire temperature transmitter • 1000 ohm, Class A platinum RTD sensing element • 4-20mA analog output signal • Probes made of durable 316 stainless steel • Temperature ranges of 0-100°C or 0-300°F
Motors
• cULus File number E 324411 • CE • RoHS
Power Transmission Motion: Servos and Steppers Motor Controls
TTD25N
TTD25C
Sensors: Proximity
ProSense Temperature Transmitter Series Part Number
Description
Sensors: Photoelectric
Pcs/Pkg Wt(lb) Price Use With Cable Assemblies
mA output, 8.3 mm (0.3”) dia. probe, 1/4” NPT male TTD25N-20-0100C-H 4-20 port, 4-pin micro M12 plug. Temperature range: 0 to 100°C.
1
0.30
$126.00
N/A
TTD25N-20-0300F-H
4-20 mA output, 8.3 mm (0.3”) dia. probe, 1/4” NPT male port, 4-pin micro M12 plug. Temperature range: 0 to 300°F .
1
0.30
$126.00
N/A
TTD25C-20-0100C-H
4-20 mA output, 6 mm (0.24”) dia. probe, 4-pin micro M12 plug. Temperature range: 0 to 100°C.
1
0.30
$126.00
CF06-25N
mA output, 6 mm (0.24”) dia. probe, 4-pin micro M12 TTD25C-20-0300F-H 4-20 plug. Temperature range: 0 to 300°F.
1
0.32
$126.00
CF06-25N
CD12L-0B-020-A0 CD12L-0B-020-C0 CD12M-0B-070-A1 CD12M-0B-070-C1 CDP12-0B-010-AA CDP12-0B-030-AA CDP12-0B-010-BB CDP12-0B-030-BB (order separately - See Proximity Sensor section for cable specs)
TTD25N-20-0100C-H
TTD25C-20-0100C-H
TTD25C-20-0300F-H
10 to 30 VDC M12 connector; gold-plated contacts 1/4” MNPT
Sensors: Current
Sensors: Temperature Sensors: Level
Use CF06-25N Yes (non-latching)
Sensors: Flow Switches
Yes Yes
Pushbuttons and Lights
4 to 20 mA (min/max 3.85 to 22 mA)
Pressure Rating Accuracy Resolution Measuring Element Measuring Range Dynamic Response (DIN EN 60751) Minimum Installation Depth Housing Material Materials (wetted parts) Ambient Temperature Storage Temperature Protection Insulation Resistance Shock Resistance Vibration Resistance EMC EN 61000-4-2 ESD EN 61000-4-3 HF Radiated EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 HF Conducted
TTD25N-20-0300F-H
Sensors: Limit Switches
Sensors: Pressure
ProSense TTD25 Series Technical Specifications Operating Voltage Electrical Connection Process connection Short-Circuit Protection Overload Protection Reverse Polarity Protection Analog Output Maximum Load
Sensors: Encoders
720Ω a t 24 VD C; Rm a x = (Su p p ly v o lt a g e - 9.6)*50 725 psi (50 bar) (This value applies to the sensor only. For installation in adapters, use the adapter data sheet indications) ± 0.4°C ± 0.3°C ± 0.4°C
Stacklights
4350 psi (300 bar) ± 0.3°C
<0.02°C
Process
1 x Pt 1000, to DIN EN 60751, class A 32 to 212°F (0 to 100°C)
0 to 300°F (-17.8 to 148.9°C)
Signal Devices
32 to 212°F (0 to 100°C)
0 to 300°F (-17.8 to 148.9°C)
*t0.5 = 1 sec/ t0.9 = 3 sec
*t0.5 = 1 sec/ t0.9 = 3 sec
N/A
0.6 in (15 mm)
Relays and Timers Pneumatics: Air Prep
Stainless steel (316S12); stainless steel (304S15); stainless steel (303S22); PA Stainless steel (316S12)
Pneumatics: Directional Control Valves
–13 to 158°F (–25 to 70°C) –40 to 212°F (–40 to 100°C)
Pneumatics: Cylinders
IP 68 / IP 69K, Class III > 100 MΩ (500 VDC)
Pneumatics: Tubing
50g (DIN / IEC 68-2-27, 11ms) 20g (DIN / EN 68-2-6, (10 to 2000 Hz)
Pneumatics: Air Fittings
4 kV CD/8 kV AD 10 V/m 2 kV 1 kV 10 V
Appendix Book 2 Terms and Conditions
* t0.5 = a 50% of full scale change in output when immersed in water at 0.4m/s, t0.9 = a 90% FS change.
NOTE: CHECK THE CHEMICAL COMPATIBILITY OF THE SENSOR’S WETTED PARTS WITH THE MEDIUM TO BE MEASURED. www.automationdirect.com/static/specs/prosensechemresistance.pdf TTD25C series may be used with RTDTW-10-010-50N Thermowell & CF06-25N fitting when isolation is required. Please refer to “Thermowells for RTD Probes with M12 Cable Connector” pages for further information. Book 2 (14.1)
w w w. a u to m at i o n d i re c t . c o m / te m p e rat u re - s e n s o rs
Temperature Sensors
eTE-7
Prices as of April 16, 2014. Check Web site for most current prices.
TTD25 Temperature Transmitters TTD25C Series Dimensions
TTD25N Series Dimensions
mm [inches]
mm [inches]
NOTE: USE PROSENSE COMPRESSION FITTING CF06-25N TO MOUNT TTD25C SERIES TEMPERATURE TRANSMITTER.
Wiring Diagram L
(+) (-)
n.c. = not connected
Cable Assembly Wiring Colors: Pin 1 - Brown Pin 2 - White Pin 3 - Blue Pin 4 - Black Note: wiring colors are based on AutomationDirect CD12L and CD12M 4-pole cable assemblies.
Book 2 (14.1)
eTE-8
Temperature Sensors
1 - 80 0 - 633 - 0405
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Cables with quick-disconnect plugs
• PVC (polyvinyl chloride) jacket for typical industrial applications • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated
• Industry standard axial and right-angle M8/M12 screw-lock connectors with open leads. The cables listed can be used with patch cables • 2m, 3m, 5m, 7m, 10m and 15m cable lengths
Power Distribution Blocks Wiring Accessories
CD08-0A-020-C1 and -A1 shown
Multi-wire Connectors
M8 Quick-Disconnect Cables (Pico, Nano) Part Number Price M8 Quick-Disconnects $7.75 CD08-0A-020-A1 $7.75 CD08-0A-020-C1 $10.50 CD08-0A-050-A1 $11.25 CD08-0C-050-A1 $10.50 CD08-0A-050-C1 $11.25 CD08-0C-050-C1 $12.00 CD08-0A-070-A1 $12.00 CD08-0A-070-C1
Length
Poles
Connector
Sensor Cables and Connectors
Jacket
Dimensions CD08-0A-050-C1 and -A1 shown
2m (6.5 ft.)
3
Axial female
PVC
Figure 1
2m (6.5 ft.)
3
Right-angle female
PVC
Figure 2
5m (16.4 ft.)
3
Axial female
PVC
Figure 4
5m (16.4 ft.)
3
Axial female
PUR
Figure 3
5m (16.4 ft.)
3
Right-angle female
PVC
Figure 5
5m (16.4 ft.)
3
Right-angle female
PUR
Figure 5
7m (23 ft.)
3
Axial female
PVC
Figure 1
7m (23 ft.)
3
Right-angle female
PVC
Figure 2
Wiring Duct Cable Ties
CD12L-0B-020-A0 and -C0 shown
Poles
Connector
5m (16.4 ft)
3
Axial female
PVC
5m (16.4 ft)
3
Axial female
PUR
Figure 9
5m (16.4 ft)
3
Right-angle female
PVC
Figure 10
5m (16.4 ft)
3
Right-angle female
PUR
Figure 11
2m (6.5 ft)
4
Axial female
PVC
Figure 6
2m (6.5 ft)
4
Right-angle female
PVC
Figure 7
7m (23 ft)
4
Axial female
PVC
Figure 6
Flexible Cord
Jacket Dimensions
Data Cables
Figure 8
7m (23 ft)
4
Right-angle female
PVC
Figure 7
10m (32.8 ft) 15m (49.2 ft) 10m (32.8 ft)
4 4 4
Axial female Axial female Right-angle female
PVC PVC PVC
Figure 13 Figure 13 Figure 14
15m (49.2 ft)
4
Right-angle female
PVC
Figure 14
3m (9.8 ft)
5
Axial female
PVC
Figure 15
5m (16.4 ft)
5
Axial female
PVC
Figure 15
10m (32.8 ft)
5
Axial female
PVC
Figure 15
3m (9.8 ft)
5
Right-angle female
PVC
Figure 16
5m (16.4 ft)
5
Right-angle female
PVC
Figure 16
10m (32.8 ft) 3m (9.8 ft) 5m (16.4 ft)
5 8 8
Right-angle female Axial female Axial female
PVC PUR PUR
Figure 16 Figure 17 Figure 17
10m (32.8 ft)
8
Axial female
PUR
Figure 17
3m (9.8 ft)
8
Right-angle female
PUR
Figure 18
5m (16.4 ft)
8
Right-angle female
PUR
Figure 18
10m (32.8 ft)
8
Right-angle female
PUR
Figure 18
3m (9.8 ft)
12
Axial female
PUR
Figure 19
5m (16.4 ft)
12
Axial female
PUR
Figure 19
10m (32.8 ft)
12
Axial female
PUR
Figure 19
3m (9.8 ft)
12
Right-angle female
PUR
Figure 20
5m (16.4 ft)
12
Right-angle female
PUR
Figure 20
10m (32.8 ft)
12
Right-angle female
PUR
Figure 20
CD12M-0B-050-C1 and -A1 shown
Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection
7000-12221-2141000
Tools Test Equipment Enclosures
7000-12241-2150500
Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
7000-17041-2951000
7000-19041-7050500 Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wire
Multi-conductor Flex Cable
Length
* Note: Do not use with sensors that require 4-pole cables.
M12 Junction Blocks Panel Interface Connectors
M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number Price M12 Quick-Disconnects $10.50 CD12M-0B-050-A1* $12.50 CD12M-0D-050-A1* $10.50 CD12M-0B-050-C1* $12.50 CD12M-0D-050-C1* $7.75 CD12L-0B-020-A0 $7.75 CD12L-0B-020-C0 $12.00 CD12M-0B-070-A1 $12.00 CD12M-0B-070-C1 7000-12221-2141000 $14.00 7000-12221-2141500 $19.00 7000-12341-2141000 $14.00 7000-12341-2141500 $19.00 7000-12241-2150300 $9.00 7000-12241-2150500 $11.50 7000-12241-2151000 $17.00 7000-12361-2150300 $9.00 7000-12361-2150500 $11.50 7000-12361-2151000 $17.00 7000-17041-2950300 $20.50 7000-17041-2950500 $26.00 7000-17041-2951000 $39.50 7000-17061-2950300 $20.50 7000-17061-2950500 $26.00 7000-17061-2951000 $39.50 7000-19041-7050300 $32.00 7000-19041-7050500 $39.00 7000-19041-7051000 $56.50 7000-19061-7050300 $32.00 7000-19061-7050500 $39.00 7000-19061-7051000 $56.50
ZIPLink Connection System
Wiring Solutions
eWD-71
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Shielded M12 Cables with quick-disconnect plugs • Industry standard axial and right-angle M12 screw-lock connectors with open leads • Braided shield located inside the cord jacket and connected to the coupling nut
• 5m and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated
Shielded M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number
Price Length
M12 Quick-Disconnects (shielded) 7000-13201-3310500 $18.00 5m (16.4 ft) 7000-13201-3311000 $27.50 10m (32.8 ft) 7000-13261-3310500 $18.00 5m (16.4 ft) 7000-13261-3311000 $27.50 10m (32.8 ft) 7000-13221-3490500 $21.00 5m (16.4 ft) 7000-13221-3491000 $32.50 10m (32.8 ft) 7000-13281-3490500 $21.00 5m (16.4 ft) 7000-13281-3491000 $32.50 10m (32.8 ft) 7000-17121-2940500 $34.50 5m (16.4 ft) 7000-17121-2941000 $52.00 10m (32.8 ft) 7000-17141-2940500 $34.50 5m (16.4 ft) 7000-17141-2941000 $52.00 10m (32.8 ft)
7000-17121-2941000
7000-17141-2940500
Poles
Connector
Jacket Dimensions
4
Axial female
PUR
Figure 21
4
Axial female
PUR
Figure 21
4
Right-angle female
PUR
Figure 22
4
Right-angle female
PUR
Figure 22
5
Axial female
PUR
Figure 23
5
Axial female
PUR
Figure 23
5
Right-angle female
PUR
Figure 24
5
Right-angle female
PUR
Figure 24
8
Axial female
PUR
Figure 25
8
Axial female
PUR
Figure 25
8
Right-angle female
PUR
Figure 26
8
Right-angle female
PUR
Figure 26
Cables with LED and quick-disconnect plugs • Industry standard M12 right angle femaleplug with open leads • These cables can be used with patch cables. • 2m, 5m and 10m cable lengths
• PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10-36 VDC PNP sensors only
M12 Quick-Disconnect Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length Poles Connector
white wire Pin 2
black wire Pin 4
LED Jacket Dimensions
M12 Quick-Disconnects EVC178* $11.00 2m (6.5 ft)
4
Right-angle female Yes
PUR
Figure 12
EVC179* $11.50 5m (16.4 ft)
4
Right-angle female Yes
PUR
Figure 12
EVC180* $14.00 10m (32.8 ft)
4
Right-angle female Yes
PUR
Figure 12
LED Models’ Wiring
*Note: LED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function.
Book 3 (14.1)
eWD-72
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Cable Specifications Specification Length Nominal Voltage
M8
CD Series
2m (6.5 ft) / 7m (23 ft)
5m (16.4 ft)
50 VAC/75 VDC
60 VAC/VDC
Max Current
2m (6.5 ft) / 7m (23 ft)
IP67
IP65 / IP68 / IP69K
ZIPLink Connection System
30 VAC/VDC; 125 VAC/VDC; 250 VAC/VDC
Multi-wire Connectors
3/4 pin: 250 VAC/VDC, 4A 5 pin: 125 VAC/VDC, 4A 8 pin: 30 VAC/VDC, 2A 12 pin: 30 VAC/VDC, 1.5A
Sensor Cables and Connectors M12 Junction Blocks
PVC: IP68 PUR: IP68 / IP69K
IP67
Nickel plated brass
Housing Material
Panel Interface Connectors
IP67 Nickel plated Zinc
Wiring Duct
Polyurethane (PUR) or Polyvinyl-chloride (PVC)
Contacts Material
Conductors Cross Section (AWG)
Wiring Accessories
3m (9.8 ft) / 5m (16.4 ft) / 10m (32.8 ft) / 15m (49.2 ft)
N/A
Material Nut
Tightening Torque
5m (16.4 ft)
4A
LED Current Loading Protection Degree
M12 7000 Series (unshielded)
250 VAC/VDC
4A
Power Distribution Blocks
Gold plated Copper-Tin Alloy (CuSn)
Cable Ties
Gold plated brass
0.5 Nm
m 0.4 Nm
0.5 Nm
m 0.4 Nm
0.6 Nm
0.25 mm2
0.25 mm2
0.25 mm2
0.34 mm2
(24 AWG)
(24 AWG)
(24 AWG)
(22 AWG)
4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG) 12 x 0.14 mm2 (12 x 26 AWG)
5mm
PVC: 4mm PUR: 4mm
5mm
PVC: 4.2 mm PUR: 4.3 mm
-25° to +80°C (-13° to 176°F)
-25° to 90°C (-13° to 194°F)
N/A
Halogen/Silicone free
Wire Flexible Cord Multi-conductor Flex Cable Data Cables
Ø Outer Cable
Temperature Range
Drag Chain (Roller Cable Tray) Suitability
Environmental Function Display Power LED Switching Status LED
PVC: -30° to 70°C -25° to +80°C (-22° to 158°F) (-13° to 176°F) PUR: -50° to 90°C (-58° to 194°F) N/A
Halogen/Silicone free
Wire Management Products Power Supplies
PVC: -25° to +70°C (-13° to 158°F) PUR: -25° to +85°C (-13° to 185°F)
DC Converters Transformers and Filters
N/A
N/A
Circuit Protection
N/A
Tools
Bending Radius
min. 10 x cable diameter
Bending Cycles
N/A
Travel Speed
N/A
Torsional Strain
N/A
Agency Approvals
PVC: 5 - 5.2 mm PUR: 6.0 mm
Test Equipment Enclosures
RoHS
Enclosure Climate Control Safety: Electrical Components
RoHS (UL E325311 8/12 pole)
Safety: Protective Wear Terms and Conditions
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-73
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Cable Specifications
M12 7000 Series (shielded)
M12 with LED
Length
5m (16.4 ft) / 10m (32.8 ft)
2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft)
Nominal Voltage
30 VAC/VDC / 60 VAC/VDC
10 to 36 VDC
Specification
Max Current
2A / 4A
4A
LED Current Loading
N/A
10 V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA
Protection Degree
IP67
IP67 / IP68 / IP69K
Nickel plated Zinc
Nickel plated Brass
Material Nut Jacket Material
Polyurethane (PUR)
Housing Material Contacts Material Tightening Torque
Polyurethane (PUR) Gold plated Brass 0.6 Nm
0.6 to 1.5 Nm
4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG)
4 x 0.34 mm2
Ø Outer Cable
4/5 pole: 5.9 mm 8 pole: 7mm
5mm
Temperature Range
-25° to +80°C (-13° to 176°F)
-25° to +90°C (-13° to 194°F)
Function Display Power LED
N/A
Green
Switching Status LED Bending Radius Bending Cycles
N/A
Drag Chain (Roller Cable Tray) Suitability
Conductors Cross Section (AWG)
Travel Speed
Torsional Strain Agency Approvals
(4 x 22 AWG)
2 x Yellow min. 10 x cable diameter
N/A N/A
>5 million Max. 3.3 m/s for a horizontal travel length of 5 meters and max. acceleration of 5 m/s2
N/A
±180°/m
RoHS
UL File E191684, RoHS
UL Reference Part Number Mini-Series Female Cord Connectors Series M12, UL Catalog Number ADOAH043MSS0002H04 EVC178 ADOAH043MSS0005H04 EVC179 ADOAH043MSS0010H04 EVC180 Note: Shown in UL file under Mini-series Female Cord Connectors using catalog number
Book 3 (14.1)
eWD-74
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Dimensions
Power Distribution Blocks
mm [inches]
Figure 1
Wiring Accessories
Figure 2
ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties
Figure 3
Figure 4
Wire Flexible Cord Multi-conductor Flex Cable Data Cables
Figure 5
Wire Management Products
Figure 6
Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control
Figure 7
Safety: Electrical Components
Figure 8
Safety: Protective Wear Terms and Conditions
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-75
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Dimensions mm [inches]
Figure 9
Figure 10
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 16
Book 3 (14.1)
eWD-76
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Dimensions
Power Distribution Blocks
mm [inches]
Wiring Accessories
Figure 17
Figure 18
ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks
Figure 19
Panel Interface Connectors
Figure 20
Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables
Figure 21
Wire Management Products
Figure 22
Power Supplies DC Converters Transformers and Filters Circuit Protection Tools
Figure 23
Test Equipment
Figure 24
Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
Figure 25
Figure 26
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-77
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Patch cables with quick-disconnect plugs on each end Available patch cables include: • Industry standard M8 and M12 screw-lock connectors • One male and one female connector • Axial and right-angle connector models
• 1m and 3m cable lengths • PVC (polyvinyl chloride)jacket for typical industrial applications • IP67 rated
M8 Patch Cables with Quick-Disconnect on Each End (Pico, Nano) Part Number Price Length M8 Quick-Disconnect Patch Cables
Poles
Connectors
Jacket
Dimensions
2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector
PVC
Figure 1
PVC
Figure 3
PVC
Figure 2
PVC
Figure 3
CDP08-0A-010-AA
$7.75
1m (3.28 ft)
3
CDP08-0A-010-BB
$7.75
1m (3.28 ft)
3
CDP08-0A-030-AA
$9.50
3m (9.84 ft)
3
CDP08-0A-030-BB
$7.75
3m (9.84 ft)
3
M12 Patch Cables with Quick-Disconnect on Each End (Euro, Micro DC-Single Key) Part Number Price Length M12 Quick-Disconnect Patch Cables
Poles
CDP12-0B-010-AA
$7.75 1m (3.28 ft.)
4
CDP12-0B-010-BB
$7.75 1m (3.28 ft.)
4
CDP12-0B-030-AA
$7.75 3m (9.84 ft.)
4
CDP12-0B-030-BB
$9.50 3m (9.84 ft.)
4
7000-40041-2150100 $11.50 1m (3.28 ft.)
5
7000-40041-2150300 $14.00 3m (9.84 ft.)
5
Connectors 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Axial - One male and one female connector
Jacket
Dimensions
PVC
Figure 4
PVC
Figure 5
PVC
Figure 4
PVC
Figure 5
PVC
Figure 7
PVC
Figure 7
Patch Cables with LED white wire Pin 2
Available patch cables with LED include: • Right-angle M12 female plug with LED indication on one end and axial male plug on the other end • 0.3m, 0.6m, 1m, 2m, 5m, and 10m cable lengths
• PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10 -36 VDC PNP sensors only
M12 Patch Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length M12 Patch Cables
black wire Pin 4
LED Models’ Wiring
Poles Connectors
LED Jacket Dimensions
EVC322* $11.00 0.3m (0.98 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC323* $12.00 0.6m (1.97 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC324* $12.50 1m (3.28 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC325* $14.50 2m (6.5 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC326* $17.00 5m (16.4 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
EVC327* $21.50 10m (32.8 ft)
4
Right-angle female, axial male
Yes
PUR
Figure 6
*Note: L ED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function. Book 3 (14.1)
eWD-78
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks Power Distribution Blocks
Cable Specifications Specification Length
M8
M12
1m (3.28 ft.) / 3m (9.84 ft.)
Nominal Voltage
4A
LED Current Consumption
N/A
Material Nut Jacket Material Housing Material Contacts Material Conductors Cross Section (AWG) Tightening Torque
Drag Chain (Roller Cable Tray) Suitability
Ø Outer Cable Temperature Range Function Display LED Switching Status LED
Wiring Accessories
0.3m (0.98 ft) / 0.6m (1.97 ft) / 1m (3.28 ft) 2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft)
125 VAC/VDC 250 VAC/VDC
60 VAC/VDC
Max Current
Protection Degree
M12 with LED
ZIPLink Connection System
10 to 36 VDC
Multi-wire Connectors
4A 10V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA
Sensor Cables and Connectors M12 Junction Blocks
IEC IP67 Zinc pressure die casting surface Nickel plated brass (Ni4-6), Nickel plated brass PolyVinyl Chloride (PVC)
IEC IP67/IP68/IP69K
Polyurethane (PUR)
Connector: Orange PUR, Socket: Black PUR
Copper-tin(CuSn) plated brass
Gold plated brass
0.34 mm²
0.34 mm² (22 AWG) Plug: 0.6 to 1.5 Nm (take into account the maximum value of the counterpart) Socket: 0.6 to 1.5 Nm 5mm
0.5 Nm
0.6 Nm, 0.5 Nm
5mm
5.2 mm, 5mm
Panel Interface Connectors
Nickel plated brass
Wiring Duct
Polyurethane (PUR)
-25° to +70°C (-13° to 158°F)
-25° to +90°C (-13° to 194°F)
N/A
Green
N/A
Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products
2 x Yellow
Bending Radius
min. 10 x cable diameter
Power Supplies
Bending Cycles
>5 million
DC Converters
Travel Speed Torsional Strain
Agency Approvals
N/A
Max. 3.3 m/s for a horizontal travel length of 5 m and max. acceleration of 5 m/s²
N/A
±180°/m
RoHS
UL File E191684, RoHS
Transformers and Filters Circuit Protection Tools Test Equipment
UL Reference Part Number EVC322 EVC323 EVC324 EVC325 EVC326 EVC327
Enclosures
Cable Assemblies Series M12, UL Catalog Number VDOAH043MSS00.3H04STGH040MSS VDOAH043MSS00.6H04STGH040MSS VDOAH043MSS0001H04STGH040MSS VDOAH043MSS0002H04STGH040MSS VDOAH043MSS0005H04STGH040MSS VDOAH043MSS0010H04STGH040MSS
Note: S hown in UL file under Cable Assemblies using catalog number
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-79
Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors Dimensions Figure 1
mm [inches]
Figure 3
Figure 2
Figure 4
Figure 6
Figure 5
Figure 7
Book 3 (14.1)
eWD-80
Wiring Solutions
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of April 16, 2014. Check Web site for most current prices.
Sensor Cables and Connectors
Company Information Terminal Blocks
Cables with quick-disconnect plugs for DFT/DFP Sensor Models
Power Distribution Blocks
Do not use extension cables with the cables listed below. The physical pin configurations do not match.
Wiring Accessories
Available cables include: • Industry standard M8 screw-lock connectors • Axial and right-angle connector models • 2m, 5m and 10m cable lengths • PVC (polyvinyl chloride) jacket for typical industrial applications • IP68 rated
ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors
M8 Cables with Quick-Disconnect Part Number
Price
Length
Poles
Connectors
Jacket
Dimensions
Wiring Duct
M8 Quick-Disconnects
Cable Ties
CD08-0G-020-A1
$8.75
2m (6.56 ft.)
4
Axial female
PVC
Figure 1
CD08-0W-020-C1
$8.75
2m (6.56 ft.)
4
Right-angle female
PVC
Figure 2
Wire
CD08-0G-050-A1
$10.50 5m (16.4 ft.)
4
Axial female
PVC
Figure 1
Flexible Cord
CD08-0W-050-C1
$10.50 5m (16.4 ft.)
4
Right-angle female
PVC
Figure 2
CD08-0G-100-A1
$13.25 10m (32.8 ft.)
4
Axial female
PVC
Figure 1
CD08-0W-100-C1
$13.25 10m (32.8 ft.)
4
Right-angle female
PVC
Figure 2
Dimensions (mm) Cable Specifications
M8
Use these cables if the sensor pin configuration looks like the connector pin-out below. M8 Connector
Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies
Figure 1
DC Converters
Length
2m (6.56 ft.) 5m (16.4 ft.) 10m (32.8 ft.)
Transformers and Filters
Nominal Voltage
30VAC/30VDC
Circuit Protection
Nominal Current
4A
Protection Degree Contact Body Material
PUR
Contacts Material
CuSn
Ø Outer Cable Temperature Range
Test Equipment
ABS
Housing Material Conductors Section
Tools
IEC IP67
0.25 mm2
Enclosures
Figure 2
Enclosure Climate Control
4.5 mm
Safety: Electrical Components
-5° to +70°C (23° to 158°F)
Safety: Protective Wear Terms and Conditions
Book 3 (14.1)
w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s
Wiring Solutions
eWD-81
Prices as of April 16, 2014. Check Web site for most current prices.
Compression Mounting Fittings for Temperature Probes Compression Mounting Fittings for Temperature Probes
Drives Soft Starters Motors
BCF18-125N Pcs/ Wt(lb) Price Pkg
Part Number Description
Company Information
Power Transmission
BCF18-125N Compression fitting, brass, for 1/8 inch diameter temperature probes,1/8 inch NPT male thread
1
0.5
$2.50
BCF14-125N Compression fitting, brass, for 1/4 inch diameter temperature probes,1/8 inch NPT male thread
1
0.5
$2.50
BCF18-25N
Compression fitting, brass, for 1/8 inch diameter temperature probes,1/4 inch NPT male thread
1
0.5
$3.00
BCF14-25N
Compression fitting, brass, for 1/4 inch diameter temperature probes,1/4 inch NPT male thread
1
0.5
$3.00
BCF18-50N
Compression fitting, brass, for 1/8 inch diameter temperature probes,1/2 inch NPT male thread
1
0.5
$4.50
BCF14-50N
Compression fitting, brass, for 1/4 inch diameter temperature probes,1/2 inch NPT male thread
1
0.5
$3.00
CF18-125N
Compression fitting, 316 stainless steel, for 1/8 inch diameter temperature probes,1/8 inch NPT male thread
1
0.5
$6.25
CF14-125N
Compression fitting, 316 stainless steel, for 1/4 inch diameter temperature probes,1/8 inch NPT male thread
1
0.5
$6.25
CF18-25N
Compression fitting, 316 stainless steel, for 1/8 inch diameter temperature probes,1/4 inch NPT male thread
1
0.5
$7.25
CF14-25N
Compression fitting, 316 stainless steel, for 1/4 inch diameter temperature probes,1/4 inch NPT male thread
1
0.5
$7.25
CF18-50N
Compression fitting, 316 stainless steel, for 1/8 inch diameter temperature probes,1/2 inch NPT male thread
1
0.5
$10.75
Sensors: Temperature
CF14-50N
Compression fitting, 316 stainless steel, for 1/4 inch diameter temperature probes,1/2 inch NPT male thread
1
0.5
$10.75
Sensors: Level
CFTF-18
Teflon™ ferrule for brass or stainless steel compression fittings and 1/8 diameter temperature probes
5
0.5
$6.00
Sensors: Flow Switches
CFTF-14
Teflon ferrule for brass or stainless steel compression fittings and 1/4 diameter temperature probes
5
0.5
$6.50
Motion: Servos and Steppers Motor Controls Sensors: Proximity
BCF18-25N
Sensors: Photoelectric Sensors: Encoders Sensors: Limit Switches Sensors: Current Sensors: Pressure
BCF18-50N
Pushbuttons and Lights
BB125N-50N
CF06-25N
1/4 NPT stainless steel compression fitting for 0.24 inch (6 mm) diameter RTD probe with M12 connector.
1
0.18
$24.00
CF10-50N
1/2 NPT stainless steel compression fitting for 10 mm (0.4 inch) diameter RTD probe with M12 connector.
1
0.20
$25.00
CF18-BC
Bayonet compression fitting, for 1/8” diameter probe sheath sensors
1
0.1
$8.00
BB125N-50N
Reducing bushing, brass, 1/2 MNPT x 1/8 FNPT, hex head
1
0.1
$4.00
NOTE: CHECK THE CHEMICAL COMPATIBILITY OF THE SENSOR’S WETTED PARTS WITH THE MEDIUM TO BE MEASURED.
Stacklights Signal Devices Process Relays and Timers Pneumatics: Air Prep
CFTF-14
*Working pressure of compression fitting should not exceed 500 psi. However we recommend any pressure application use a thermowell
CF14-125N
CF14-50N
Pneumatics: Directional Control Valves
CF14-25N
Pneumatics: Cylinders Pneumatics: Tubing
CFTF-18
Pneumatics: Air Fittings
CF18-BC
Appendix Book 2
CF06-25N
CF10-50N
Terms and Conditions
Book 2 (14.1)
w w w. a u to m at i o n d i re c t . c o m / te m p e rat u re - s e n s o rs
Temperature Sensors
eTE-69
Prices as of April 16, 2014. Check Web site for most current prices.
Compression Mounting Fittings for Temperature Probes BCF14-125N
BCF14-25N
BCF14-50N
CF18-25N
CF18-50N
CF18-125N
Dimensions
Note: All threaded connections should be hand tightened and then turned 1 to 2 full turns for proper sealing. Actual torque required for a proper seal of NPT threads is influenced by tolerance, sealant, lubricant, etc.
ProSense Compression Fittings Part No. BCF18-125N/ CF18-125N BCF14-125N/ CF14-125N BCF18-25N/ CF18-25N BCF14-25N/ CF14-25N BCF18-50N/ CF18-50N BCF14-50N/ CF14-50N CF06-25N CF10-50N
Weight (lb)
Description
“T” Tube O.D.
“P” NPT(M)
“L” Body “L1” Thread “F” Body “G” Nut Length* Length** Hex** Hex**
“NL” Nut Length**
0.5
1/8” OD x 1/8” NPT(M)
0.128/0.132
1/8” NPT(M)
0.909”
0.393”
0.5”
0.433”
0.492”
0.5
1/4” OD x 1/8” NPT(M)
0.253/0.257
1/8”NPT(M)
1.0”
0.393”
0.5”
0.559”
0.5”
0.5
1/8” OD x 1/4” NPT(M)
0.128/0.132
1/4” NPT(M)
1.114”
0.551”
0.551”
0.433”
0.492”
0.5
1/4” OD x 1/4” NPT(M)
0.253/0.257
1/4” NPT(M)
1.188”
0.551”
0.551”
0.559”
0.5”
0.5
1/8” OD x 1/2” NPT(M)
0.128/0.132
1/2” NPT(M)
1.377”
0.748”
0.866”
0.433”
0.492”
0.5
1/4” OD x 1/2” NTP(M)
0.253/0.257
1/2” NPT(M)
1.437”
0.748”
0.866”
0.559”
0.5”
0.18
6 mm OD x 1/4” NPT(M)
0.236/0.240
1/4” NPT(M)
1.174”
0.59”
0.67”
0.55”
0.587”
0.20
10 mm OD x 1/2” NPT(M)
0.394/0.399
1/2” NPT(M)
1.458”
0.55”
1.06”
0.75”
0.608”
Note: All dimensions are in inches * 0.07 ** 0.03 Note: Once the compression fitting has been fully tightened on the probe, the ferrule will be locked onto the probe and cannot be removed or reused. *Working pressure of compression fitting should not exceed 500 psi. However we recommend any pressure application use a thermowell
Book 2 (14.1)
eTE-70
Temperature Sensors
1 - 80 0 - 633 - 0405
Prices as of April 16, 2014. Check Web site for most current prices.
Bayonet Mounting Adapter for Temperature Sensors
Company Information Drives Soft Starters
Bayonet Mounting Adapter for Temperature Sensors
Motors
Pcs/ Wt(lb) Price Pkg
Part Number Description BA-078
Bayonet adapter, 7/8 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT
1
0.5
$1.25
BA-100
Bayonet adapter, 1 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT
1
0.5
$1.25
BA-114
Bayonet adapter, 1-1/4 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT
1
0.5
$1.50
BA-112
Bayonet adapter, 1-1/2 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter,1/8 inch MNPT
1
0.5
$1.75
BA-200
Bayonet adapter, 2 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT
1
0.5
$2.00
BA-212
Bayonet adapter, 2-1/2 long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT
1
0.5
$2.25
BA-300
Bayonet adapter, 3 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT
1
0.5
$2.50
BA-312
Bayonet adapter, 3-1/2 long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT
1
0.5
$2.75
CF18-BC
Adjustable bayonet compression fitting, for 1/8” diameter probe sheath sensors
1
0.1
$8.00
1
0.1
$4.00
BA-078 Power Transmission Motion: Servos and Steppers Motor Controls Sensors: Proximity Sensors: Photoelectric
BA-100
Sensors: Encoders Sensors: Limit Switches Sensors: Current Sensors: Pressure
BA-114 BB125N-50N Reducing bushing, brass, 1/2 MNPT x 1/8 FNPT, hex head
Sensors: Temperature Sensors: Level
NOTE: CHECK THE CHEMICAL COMPATIBILITY OF THE SENSOR’S WETTED PARTS WITH THE MEDIUM TO BE MEASURED.
Sensors: Flow Switches Pushbuttons and Lights Stacklights
CF18-BC
BA-300
BA-112 Signal Devices Process Relays and Timers Pneumatics: Air Prep
BB125N-50N
BA-312
Pneumatics: Directional Control Valves
BA-200
Pneumatics: Cylinders Pneumatics: Tubing Pneumatics: Air Fittings Appendix Book 2
BA-212
Terms and Conditions
Book 2 (14.1)
w w w. a u to m at i o n d i re c t . c o m / te m p e rat u re - s e n s o rs
Temperature Sensors
eTE-71
Prices as of April 16, 2014. Check Web site for most current prices.
Thermocouple and RTD Temperature Range Thermocouple Temperature Range THMK-C06-04 THMK-C12-04 THMK-C18-04 32 to 2100°F (0 to 1149°C) THMK-H06L01-03 THMK-H12L01-03 THMK-H18L01-03 THMK-T06L06-03 32 to 2100°F (0 to 1149°C) lead wire transition rated to THMK-T12L06-03 204°C (400°F) THMK-T18L06-03 TTD25C-20-0300F-H 0 to 300°F (-17.8 to 148.9°C) TTD25N-20-0300F-H THMJ-A01L04-01 THMJ-A01L06-01 THMJ-A01L10-01 THMJ-A01L10-02 THMJ-B01L06-01 THMJ-B01L06-02 THMJ-B02L06-01 THMJ-B02L06-02 THMJ-D08L04-01 THMJ-D08L06-01 THMJ-D08L10-01 32 to 900°F (0 to 482°C) THMJ-D08L10-02 THMK-A01L04-01 THMK-A01L06-01 THMK-A01L10-01 THMK-A01L10-02 THMK-B01L06-01 THMK-B01L06-02 THMK-D08L04-01 THMK-D08L06-01 THMK-D08L10-01 THMK-D08L10-02 THMJ-T06L06-01 32 to 970°F (0 to 521°C), lead wire transition rated to 400 °F THMJ-T12L06-01 (204 °C) THMJ-T18L06-01 THMJ-P06-01 32 to 970°F (0 to 521°C), plug THMJ-P12-01 rated to 400 °F (204 °C) THMJ-P18-01 THMJ-C04-03 THMJ-C04R-03 THMJ-C06-01 THMJ-C06-02 THMJ-C06-03 THMJ-C06R-03 THMJ-C12-01 THMJ-C12-02 THMJ-C12-03 32 to 1330°F (0 to 720°C) THMJ-C12R-03 THMJ-C18-01 THMJ-C18-02 THMJ-H04L01-02 THMJ-H06L01-01 THMJ-H06L01-02 THMJ-H12L01-01 THMJ-H12L01-02 THMJ-H18L01-01
Thermocouple Temperature Range THMJ-T06L06-02 THMJ-T12L06-02 THMJ-T18L06-02 THMJ-P06-02 THMJ-P12-02 THMJ-P18-02 THMK-C04-03 THMK-C04R-03 THMK-C06-01 THMK-C06-02 THMK-C06-03 THMK-C06R-03 THMK-C12-01 THMK-C12-02 THMK-C12-03 THMK-C12R-03 THMK-C18-01 THMK-C18-02 THMK-H04L01-02 THMK-H06L01-01 THMK-H06L01-02 THMK-H12L01-01 THMK-H12L01-02 THMK-H18L01-01 THMK-T06L06-01 THMK-T06L06-02 THMK-T12L06-01 THMK-T12L06-02 THMK-T18L06-01 THMK-T18L06-02 THMK-P06-01 THMK-P06-02 THMK-P12-01 THMK-P12-02 THMK-P18-01 THMK-P18-02 THMK-B02L06-01 THMK-B02L06-02 THMT-P06-01 THMT-P12-01 THMT-P18-01 THMT-T06L06-01 THMT-T12L06-01 THMT-T18L06-01 TTD25C-20-0100C-H TTD25N-20-0100C-H TSD25N-0P-0284-H TSD25N-AP-0284-H
32 to 1330°F (0 to 720°C) lead wire transition rated to 400 °F (204 °C) 32 to 1330°F (0 to 720°C) plug rated to 400 °F (204 °C)
32 to 1700°F (0 to 927°C)
32 to 1700°F (0 to 927°C) lead wire transition rated to 400 °F (204 °C)
RTD Temperature Range RTD1-R01-01 RTD1-S04-01 RTD1-S04-02 RTD1-S04-03 RTD1-S04-04 RTD1-B01L06-01 RTD1-B02L06-01 RTD1-C04-03 RTD1-C04R-03 RTD1-C06-01 RTD1-C06-03 RTD1-C06R-03 RTD1-C12-01 RTD1-C12-02 RTD1-C12-03 RTD1-C12R-03 RTD1-C18-01 RTD1-C18-02 RTD1-H04L01-02 RTD1-H06L01-01 RTD1-H06L01-02 RTD1-H12L01-01 RTD1-H12L01-02 RTD1-H18L01-01 RTD1-P06-01 RTD1-P12-01 RTD1-P18-01 RTD1-D08L10-01 RTD1-T06L06-01 RTD1-T12L06-01 RTD1-T18L06-01
40 to 185°F (-40 to 85°C)
-58 to 572°F (-50 to 300°C)
-58 to 572°F (-50 to 300°C) Plug rated to 400°F (204°C)
-58 to 572°F (-50 to 300°C), lead wire transition rated to 400°F (204°C)
32 to 1700°F (0 to 927°C) plug rated to 400 °F (204 °C)
32° to 900°F (0° to 482°C)
J, K, & T Thermocouple Color Code -328 to 700°F (-200 to 371°C) plug rated to 400 °F (204 °C)
White
J Red
-328 to 700°F (-200 to 371°C), lead wire transition rated to 400 °F (204 °C)
Yellow
K Red
32 to 212°F (0 to 100°C) Blue -4 to 284°F (-20 to 140°C)
T Red
+ + + -
Book 2 (14.1)
eTE-76
Temperature Sensors
1 - 80 0 - 633 - 0405