Preview only show first 10 pages with watermark. For full document please download

Prosense Ttd25 Series Temperature Transmitter Specs

   EMBED


Share

Transcript

Prices as of April 16, 2014. Check Web site for most current prices. TTD25 Series Temperature Transmitter Company Information Drives Features Soft Starters Agency Approvals • High accuracy 2-wire temperature transmitter • 1000 ohm, Class A platinum RTD sensing element • 4-20mA analog output signal • Probes made of durable 316 stainless steel • Temperature ranges of 0-100°C or 0-300°F Motors • cULus File number E 324411 • CE • RoHS Power Transmission Motion: Servos and Steppers Motor Controls TTD25N TTD25C Sensors: Proximity ProSense Temperature Transmitter Series Part Number Description Sensors: Photoelectric Pcs/Pkg Wt(lb) Price Use With Cable Assemblies mA output, 8.3 mm (0.3”) dia. probe, 1/4” NPT male TTD25N-20-0100C-H 4-20 port, 4-pin micro M12 plug. Temperature range: 0 to 100°C. 1 0.30 $126.00 N/A TTD25N-20-0300F-H 4-20 mA output, 8.3 mm (0.3”) dia. probe, 1/4” NPT male port, 4-pin micro M12 plug. Temperature range: 0 to 300°F . 1 0.30 $126.00 N/A TTD25C-20-0100C-H 4-20 mA output, 6 mm (0.24”) dia. probe, 4-pin micro M12 plug. Temperature range: 0 to 100°C. 1 0.30 $126.00 CF06-25N mA output, 6 mm (0.24”) dia. probe, 4-pin micro M12 TTD25C-20-0300F-H 4-20 plug. Temperature range: 0 to 300°F. 1 0.32 $126.00 CF06-25N CD12L-0B-020-A0 CD12L-0B-020-C0 CD12M-0B-070-A1 CD12M-0B-070-C1 CDP12-0B-010-AA CDP12-0B-030-AA CDP12-0B-010-BB CDP12-0B-030-BB (order separately - See Proximity Sensor section for cable specs) TTD25N-20-0100C-H TTD25C-20-0100C-H TTD25C-20-0300F-H 10 to 30 VDC M12 connector; gold-plated contacts 1/4” MNPT Sensors: Current Sensors: Temperature Sensors: Level Use CF06-25N Yes (non-latching) Sensors: Flow Switches Yes Yes Pushbuttons and Lights 4 to 20 mA (min/max 3.85 to 22 mA) Pressure Rating Accuracy Resolution Measuring Element Measuring Range Dynamic Response (DIN EN 60751) Minimum Installation Depth Housing Material Materials (wetted parts) Ambient Temperature Storage Temperature Protection Insulation Resistance Shock Resistance Vibration Resistance EMC EN 61000-4-2 ESD EN 61000-4-3 HF Radiated EN 61000-4-4 Burst EN 61000-4-5 Surge EN 61000-4-6 HF Conducted TTD25N-20-0300F-H Sensors: Limit Switches Sensors: Pressure ProSense TTD25 Series Technical Specifications Operating Voltage Electrical Connection Process connection Short-Circuit Protection Overload Protection Reverse Polarity Protection Analog Output Maximum Load Sensors: Encoders 720Ω a t 24 VD C; Rm a x = (Su p p ly v o lt a g e - 9.6)*50 725 psi (50 bar) (This value applies to the sensor only. For installation in adapters, use the adapter data sheet indications) ± 0.4°C ± 0.3°C ± 0.4°C Stacklights 4350 psi (300 bar) ± 0.3°C <0.02°C Process 1 x Pt 1000, to DIN EN 60751, class A 32 to 212°F (0 to 100°C) 0 to 300°F (-17.8 to 148.9°C) Signal Devices 32 to 212°F (0 to 100°C) 0 to 300°F (-17.8 to 148.9°C) *t0.5 = 1 sec/ t0.9 = 3 sec *t0.5 = 1 sec/ t0.9 = 3 sec N/A 0.6 in (15 mm) Relays and Timers Pneumatics: Air Prep Stainless steel (316S12); stainless steel (304S15); stainless steel (303S22); PA Stainless steel (316S12) Pneumatics: Directional Control Valves –13 to 158°F (–25 to 70°C) –40 to 212°F (–40 to 100°C) Pneumatics: Cylinders IP 68 / IP 69K, Class III > 100 MΩ (500 VDC) Pneumatics: Tubing 50g (DIN / IEC 68-2-27, 11ms) 20g (DIN / EN 68-2-6, (10 to 2000 Hz) Pneumatics: Air Fittings 4 kV CD/8 kV AD 10 V/m 2 kV 1 kV 10 V Appendix Book 2 Terms and Conditions * t0.5 = a 50% of full scale change in output when immersed in water at 0.4m/s, t0.9 = a 90% FS change. NOTE: CHECK THE CHEMICAL COMPATIBILITY OF THE SENSOR’S WETTED PARTS WITH THE MEDIUM TO BE MEASURED. www.automationdirect.com/static/specs/prosensechemresistance.pdf TTD25C series may be used with RTDTW-10-010-50N Thermowell & CF06-25N fitting when isolation is required. Please refer to “Thermowells for RTD Probes with M12 Cable Connector” pages for further information. Book 2 (14.1) w w w. a u to m at i o n d i re c t . c o m / te m p e rat u re - s e n s o rs Temperature Sensors eTE-7 Prices as of April 16, 2014. Check Web site for most current prices. TTD25 Temperature Transmitters TTD25C Series Dimensions TTD25N Series Dimensions mm [inches] mm [inches] NOTE: USE PROSENSE COMPRESSION FITTING CF06-25N TO MOUNT TTD25C SERIES TEMPERATURE TRANSMITTER. Wiring Diagram L (+) (-) n.c. = not connected Cable Assembly Wiring Colors: Pin 1 - Brown Pin 2 - White Pin 3 - Blue Pin 4 - Black Note: wiring colors are based on AutomationDirect CD12L and CD12M 4-pole cable assemblies. Book 2 (14.1) eTE-8 Temperature Sensors 1 - 80 0 - 633 - 0405 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Cables with quick-disconnect plugs • PVC (polyvinyl chloride) jacket for typical industrial applications • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated • Industry standard axial and right-angle M8/M12 screw-lock connectors with open leads. The cables listed can be used with patch cables • 2m, 3m, 5m, 7m, 10m and 15m cable lengths Power Distribution Blocks Wiring Accessories CD08-0A-020-C1 and -A1 shown Multi-wire Connectors M8 Quick-Disconnect Cables (Pico, Nano) Part Number Price M8 Quick-Disconnects $7.75 CD08-0A-020-A1 $7.75 CD08-0A-020-C1 $10.50 CD08-0A-050-A1 $11.25 CD08-0C-050-A1 $10.50 CD08-0A-050-C1 $11.25 CD08-0C-050-C1 $12.00 CD08-0A-070-A1 $12.00 CD08-0A-070-C1 Length Poles Connector Sensor Cables and Connectors Jacket Dimensions CD08-0A-050-C1 and -A1 shown 2m (6.5 ft.) 3 Axial female PVC Figure 1 2m (6.5 ft.) 3 Right-angle female PVC Figure 2 5m (16.4 ft.) 3 Axial female PVC Figure 4 5m (16.4 ft.) 3 Axial female PUR Figure 3 5m (16.4 ft.) 3 Right-angle female PVC Figure 5 5m (16.4 ft.) 3 Right-angle female PUR Figure 5 7m (23 ft.) 3 Axial female PVC Figure 1 7m (23 ft.) 3 Right-angle female PVC Figure 2 Wiring Duct Cable Ties CD12L-0B-020-A0 and -C0 shown Poles Connector 5m (16.4 ft) 3 Axial female PVC 5m (16.4 ft) 3 Axial female PUR Figure 9 5m (16.4 ft) 3 Right-angle female PVC Figure 10 5m (16.4 ft) 3 Right-angle female PUR Figure 11 2m (6.5 ft) 4 Axial female PVC Figure 6 2m (6.5 ft) 4 Right-angle female PVC Figure 7 7m (23 ft) 4 Axial female PVC Figure 6 Flexible Cord Jacket Dimensions Data Cables Figure 8 7m (23 ft) 4 Right-angle female PVC Figure 7 10m (32.8 ft) 15m (49.2 ft) 10m (32.8 ft) 4 4 4 Axial female Axial female Right-angle female PVC PVC PVC Figure 13 Figure 13 Figure 14 15m (49.2 ft) 4 Right-angle female PVC Figure 14 3m (9.8 ft) 5 Axial female PVC Figure 15 5m (16.4 ft) 5 Axial female PVC Figure 15 10m (32.8 ft) 5 Axial female PVC Figure 15 3m (9.8 ft) 5 Right-angle female PVC Figure 16 5m (16.4 ft) 5 Right-angle female PVC Figure 16 10m (32.8 ft) 3m (9.8 ft) 5m (16.4 ft) 5 8 8 Right-angle female Axial female Axial female PVC PUR PUR Figure 16 Figure 17 Figure 17 10m (32.8 ft) 8 Axial female PUR Figure 17 3m (9.8 ft) 8 Right-angle female PUR Figure 18 5m (16.4 ft) 8 Right-angle female PUR Figure 18 10m (32.8 ft) 8 Right-angle female PUR Figure 18 3m (9.8 ft) 12 Axial female PUR Figure 19 5m (16.4 ft) 12 Axial female PUR Figure 19 10m (32.8 ft) 12 Axial female PUR Figure 19 3m (9.8 ft) 12 Right-angle female PUR Figure 20 5m (16.4 ft) 12 Right-angle female PUR Figure 20 10m (32.8 ft) 12 Right-angle female PUR Figure 20 CD12M-0B-050-C1 and -A1 shown Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection 7000-12221-2141000 Tools Test Equipment Enclosures 7000-12241-2150500 Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions 7000-17041-2951000 7000-19041-7050500 Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wire Multi-conductor Flex Cable Length * Note: Do not use with sensors that require 4-pole cables. M12 Junction Blocks Panel Interface Connectors M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number Price M12 Quick-Disconnects $10.50 CD12M-0B-050-A1* $12.50 CD12M-0D-050-A1* $10.50 CD12M-0B-050-C1* $12.50 CD12M-0D-050-C1* $7.75 CD12L-0B-020-A0 $7.75 CD12L-0B-020-C0 $12.00 CD12M-0B-070-A1 $12.00 CD12M-0B-070-C1 7000-12221-2141000 $14.00 7000-12221-2141500 $19.00 7000-12341-2141000 $14.00 7000-12341-2141500 $19.00 7000-12241-2150300 $9.00 7000-12241-2150500 $11.50 7000-12241-2151000 $17.00 7000-12361-2150300 $9.00 7000-12361-2150500 $11.50 7000-12361-2151000 $17.00 7000-17041-2950300 $20.50 7000-17041-2950500 $26.00 7000-17041-2951000 $39.50 7000-17061-2950300 $20.50 7000-17061-2950500 $26.00 7000-17061-2951000 $39.50 7000-19041-7050300 $32.00 7000-19041-7050500 $39.00 7000-19041-7051000 $56.50 7000-19061-7050300 $32.00 7000-19061-7050500 $39.00 7000-19061-7051000 $56.50 ZIPLink Connection System Wiring Solutions eWD-71 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Shielded M12 Cables with quick-disconnect plugs • Industry standard axial and right-angle M12 screw-lock connectors with open leads • Braided shield located inside the cord jacket and connected to the coupling nut • 5m and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 rated Shielded M12 Quick-Disconnect Cables (Euro, Micro DC-Single Key) Part Number Price Length M12 Quick-Disconnects (shielded) 7000-13201-3310500 $18.00 5m (16.4 ft) 7000-13201-3311000 $27.50 10m (32.8 ft) 7000-13261-3310500 $18.00 5m (16.4 ft) 7000-13261-3311000 $27.50 10m (32.8 ft) 7000-13221-3490500 $21.00 5m (16.4 ft) 7000-13221-3491000 $32.50 10m (32.8 ft) 7000-13281-3490500 $21.00 5m (16.4 ft) 7000-13281-3491000 $32.50 10m (32.8 ft) 7000-17121-2940500 $34.50 5m (16.4 ft) 7000-17121-2941000 $52.00 10m (32.8 ft) 7000-17141-2940500 $34.50 5m (16.4 ft) 7000-17141-2941000 $52.00 10m (32.8 ft) 7000-17121-2941000 7000-17141-2940500 Poles Connector Jacket Dimensions 4 Axial female PUR Figure 21 4 Axial female PUR Figure 21 4 Right-angle female PUR Figure 22 4 Right-angle female PUR Figure 22 5 Axial female PUR Figure 23 5 Axial female PUR Figure 23 5 Right-angle female PUR Figure 24 5 Right-angle female PUR Figure 24 8 Axial female PUR Figure 25 8 Axial female PUR Figure 25 8 Right-angle female PUR Figure 26 8 Right-angle female PUR Figure 26 Cables with LED and quick-disconnect plugs • Industry standard M12 right angle femaleplug with open leads • These cables can be used with patch cables. • 2m, 5m and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10-36 VDC PNP sensors only M12 Quick-Disconnect Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length Poles Connector white wire Pin 2 black wire Pin 4 LED Jacket Dimensions M12 Quick-Disconnects EVC178* $11.00 2m (6.5 ft) 4 Right-angle female Yes PUR Figure 12 EVC179* $11.50 5m (16.4 ft) 4 Right-angle female Yes PUR Figure 12 EVC180* $14.00 10m (32.8 ft) 4 Right-angle female Yes PUR Figure 12 LED Models’ Wiring *Note: LED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function. Book 3 (14.1) eWD-72 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Cable Specifications Specification Length Nominal Voltage M8 CD Series 2m (6.5 ft) / 7m (23 ft) 5m (16.4 ft) 50 VAC/75 VDC 60 VAC/VDC Max Current 2m (6.5 ft) / 7m (23 ft) IP67 IP65 / IP68 / IP69K ZIPLink Connection System 30 VAC/VDC; 125 VAC/VDC; 250 VAC/VDC Multi-wire Connectors 3/4 pin: 250 VAC/VDC, 4A 5 pin: 125 VAC/VDC, 4A 8 pin: 30 VAC/VDC, 2A 12 pin: 30 VAC/VDC, 1.5A Sensor Cables and Connectors M12 Junction Blocks PVC: IP68 PUR: IP68 / IP69K IP67 Nickel plated brass Housing Material Panel Interface Connectors IP67 Nickel plated Zinc Wiring Duct Polyurethane (PUR) or Polyvinyl-chloride (PVC) Contacts Material Conductors Cross Section (AWG) Wiring Accessories 3m (9.8 ft) / 5m (16.4 ft) / 10m (32.8 ft) / 15m (49.2 ft) N/A Material Nut Tightening Torque 5m (16.4 ft) 4A LED Current Loading Protection Degree M12 7000 Series (unshielded) 250 VAC/VDC 4A Power Distribution Blocks Gold plated Copper-Tin Alloy (CuSn) Cable Ties Gold plated brass 0.5 Nm m 0.4 Nm 0.5 Nm m 0.4 Nm 0.6 Nm 0.25 mm2 0.25 mm2 0.25 mm2 0.34 mm2 (24 AWG) (24 AWG) (24 AWG) (22 AWG) 4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG) 12 x 0.14 mm2 (12 x 26 AWG) 5mm PVC: 4mm PUR: 4mm 5mm PVC: 4.2 mm PUR: 4.3 mm -25° to +80°C (-13° to 176°F) -25° to 90°C (-13° to 194°F) N/A Halogen/Silicone free Wire Flexible Cord Multi-conductor Flex Cable Data Cables Ø Outer Cable Temperature Range Drag Chain (Roller Cable Tray) Suitability Environmental Function Display Power LED Switching Status LED PVC: -30° to 70°C -25° to +80°C (-22° to 158°F) (-13° to 176°F) PUR: -50° to 90°C (-58° to 194°F) N/A Halogen/Silicone free Wire Management Products Power Supplies PVC: -25° to +70°C (-13° to 158°F) PUR: -25° to +85°C (-13° to 185°F) DC Converters Transformers and Filters N/A N/A Circuit Protection N/A Tools Bending Radius min. 10 x cable diameter Bending Cycles N/A Travel Speed N/A Torsional Strain N/A Agency Approvals PVC: 5 - 5.2 mm PUR: 6.0 mm Test Equipment Enclosures RoHS Enclosure Climate Control Safety: Electrical Components RoHS (UL E325311 8/12 pole) Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-73 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Cable Specifications M12 7000 Series (shielded) M12 with LED Length 5m (16.4 ft) / 10m (32.8 ft) 2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft) Nominal Voltage 30 VAC/VDC / 60 VAC/VDC 10 to 36 VDC Specification Max Current 2A / 4A 4A LED Current Loading N/A 10 V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA Protection Degree IP67 IP67 / IP68 / IP69K Nickel plated Zinc Nickel plated Brass Material Nut Jacket Material Polyurethane (PUR) Housing Material Contacts Material Tightening Torque Polyurethane (PUR) Gold plated Brass 0.6 Nm 0.6 to 1.5 Nm 4 x 0.34 mm2 (4 x 22 AWG) 5 x 0.34 mm2 (5 x 22 AWG) 8 x 0.25 mm2 (8 x 24 AWG) 4 x 0.34 mm2 Ø Outer Cable 4/5 pole: 5.9 mm 8 pole: 7mm 5mm Temperature Range -25° to +80°C (-13° to 176°F) -25° to +90°C (-13° to 194°F) Function Display Power LED N/A Green Switching Status LED Bending Radius Bending Cycles N/A Drag Chain (Roller Cable Tray) Suitability Conductors Cross Section (AWG) Travel Speed Torsional Strain Agency Approvals (4 x 22 AWG) 2 x Yellow min. 10 x cable diameter N/A N/A >5 million Max. 3.3 m/s for a horizontal travel length of 5 meters and max. acceleration of 5 m/s2 N/A ±180°/m RoHS UL File E191684, RoHS UL Reference Part Number Mini-Series Female Cord Connectors Series M12, UL Catalog Number ADOAH043MSS0002H04 EVC178 ADOAH043MSS0005H04 EVC179 ADOAH043MSS0010H04 EVC180 Note: Shown in UL file under Mini-series Female Cord Connectors using catalog number Book 3 (14.1) eWD-74 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Dimensions Power Distribution Blocks mm [inches] Figure 1 Wiring Accessories Figure 2 ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties Figure 3 Figure 4 Wire Flexible Cord Multi-conductor Flex Cable Data Cables Figure 5 Wire Management Products Figure 6 Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Test Equipment Enclosures Enclosure Climate Control Figure 7 Safety: Electrical Components Figure 8 Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-75 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Dimensions mm [inches] Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Book 3 (14.1) eWD-76 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Dimensions Power Distribution Blocks mm [inches] Wiring Accessories Figure 17 Figure 18 ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Figure 19 Panel Interface Connectors Figure 20 Wiring Duct Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Figure 21 Wire Management Products Figure 22 Power Supplies DC Converters Transformers and Filters Circuit Protection Tools Figure 23 Test Equipment Figure 24 Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Figure 25 Figure 26 Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-77 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Patch cables with quick-disconnect plugs on each end Available patch cables include: • Industry standard M8 and M12 screw-lock connectors • One male and one female connector • Axial and right-angle connector models • 1m and 3m cable lengths • PVC (polyvinyl chloride)jacket for typical industrial applications • IP67 rated M8 Patch Cables with Quick-Disconnect on Each End (Pico, Nano) Part Number Price Length M8 Quick-Disconnect Patch Cables Poles Connectors Jacket Dimensions 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector PVC Figure 1 PVC Figure 3 PVC Figure 2 PVC Figure 3 CDP08-0A-010-AA $7.75 1m (3.28 ft) 3 CDP08-0A-010-BB $7.75 1m (3.28 ft) 3 CDP08-0A-030-AA $9.50 3m (9.84 ft) 3 CDP08-0A-030-BB $7.75 3m (9.84 ft) 3 M12 Patch Cables with Quick-Disconnect on Each End (Euro, Micro DC-Single Key) Part Number Price Length M12 Quick-Disconnect Patch Cables Poles CDP12-0B-010-AA $7.75 1m (3.28 ft.) 4 CDP12-0B-010-BB $7.75 1m (3.28 ft.) 4 CDP12-0B-030-AA $7.75 3m (9.84 ft.) 4 CDP12-0B-030-BB $9.50 3m (9.84 ft.) 4 7000-40041-2150100 $11.50 1m (3.28 ft.) 5 7000-40041-2150300 $14.00 3m (9.84 ft.) 5 Connectors 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Right-angle - One male and one female connector 2 Axial - One male and one female connector 2 Axial - One male and one female connector Jacket Dimensions PVC Figure 4 PVC Figure 5 PVC Figure 4 PVC Figure 5 PVC Figure 7 PVC Figure 7 Patch Cables with LED white wire Pin 2 Available patch cables with LED include: • Right-angle M12 female plug with LED indication on one end and axial male plug on the other end • 0.3m, 0.6m, 1m, 2m, 5m, and 10m cable lengths • PUR (polyurethane) jacket for oily and direct sunlight applications • IP67 /IP68 / IP69K, II rated • LED indication for 10 -36 VDC PNP sensors only M12 Patch Cables with LED Indicator (Euro, Micro DC-Single Key) Part Number Price Length M12 Patch Cables black wire Pin 4 LED Models’ Wiring Poles Connectors LED Jacket Dimensions EVC322* $11.00 0.3m (0.98 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC323* $12.00 0.6m (1.97 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC324* $12.50 1m (3.28 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC325* $14.50 2m (6.5 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC326* $17.00 5m (16.4 ft) 4 Right-angle female, axial male Yes PUR Figure 6 EVC327* $21.50 10m (32.8 ft) 4 Right-angle female, axial male Yes PUR Figure 6 *Note: L ED for 10 to 36 VDC PNP devices only. Do not use with NPN or analog ouput devices. Do not use when white wire (Pin 2) is used for selection of a sensor function. Do not use when emitter has check function. Book 3 (14.1) eWD-78 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Power Distribution Blocks Cable Specifications Specification Length M8 M12 1m (3.28 ft.) / 3m (9.84 ft.) Nominal Voltage 4A LED Current Consumption N/A Material Nut Jacket Material Housing Material Contacts Material Conductors Cross Section (AWG) Tightening Torque Drag Chain (Roller Cable Tray) Suitability Ø Outer Cable Temperature Range Function Display LED Switching Status LED Wiring Accessories 0.3m (0.98 ft) / 0.6m (1.97 ft) / 1m (3.28 ft) 2m (6.5 ft) / 5m (16.4 ft) / 10m (32.8 ft) 125 VAC/VDC 250 VAC/VDC 60 VAC/VDC Max Current Protection Degree M12 with LED ZIPLink Connection System 10 to 36 VDC Multi-wire Connectors 4A 10V input Brown wire LED: 1.7 mA White and/or Black LED: 0.9 mA 36V input Brown wire LED: 7.3 mA White and/or Black LED: 4.7 mA Sensor Cables and Connectors M12 Junction Blocks IEC IP67 Zinc pressure die casting surface Nickel plated brass (Ni4-6), Nickel plated brass PolyVinyl Chloride (PVC) IEC IP67/IP68/IP69K Polyurethane (PUR) Connector: Orange PUR, Socket: Black PUR Copper-tin(CuSn) plated brass Gold plated brass 0.34 mm² 0.34 mm² (22 AWG) Plug: 0.6 to 1.5 Nm (take into account the maximum value of the counterpart) Socket: 0.6 to 1.5 Nm 5mm 0.5 Nm 0.6 Nm, 0.5 Nm 5mm 5.2 mm, 5mm Panel Interface Connectors Nickel plated brass Wiring Duct Polyurethane (PUR) -25° to +70°C (-13° to 158°F) -25° to +90°C (-13° to 194°F) N/A Green N/A Cable Ties Wire Flexible Cord Multi-conductor Flex Cable Data Cables Wire Management Products 2 x Yellow Bending Radius min. 10 x cable diameter Power Supplies Bending Cycles >5 million DC Converters Travel Speed Torsional Strain Agency Approvals N/A Max. 3.3 m/s for a horizontal travel length of 5 m and max. acceleration of 5 m/s² N/A ±180°/m RoHS UL File E191684, RoHS Transformers and Filters Circuit Protection Tools Test Equipment UL Reference Part Number EVC322 EVC323 EVC324 EVC325 EVC326 EVC327 Enclosures Cable Assemblies Series M12, UL Catalog Number VDOAH043MSS00.3H04STGH040MSS VDOAH043MSS00.6H04STGH040MSS VDOAH043MSS0001H04STGH040MSS VDOAH043MSS0002H04STGH040MSS VDOAH043MSS0005H04STGH040MSS VDOAH043MSS0010H04STGH040MSS Note: S  hown in UL file under Cable Assemblies using catalog number Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-79 Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Dimensions Figure 1 mm [inches] Figure 3 Figure 2 Figure 4 Figure 6 Figure 5 Figure 7 Book 3 (14.1) eWD-80 Wiring Solutions 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 16, 2014. Check Web site for most current prices. Sensor Cables and Connectors Company Information Terminal Blocks Cables with quick-disconnect plugs for DFT/DFP Sensor Models Power Distribution Blocks Do not use extension cables with the cables listed below. The physical pin configurations do not match. Wiring Accessories Available cables include: • Industry standard M8 screw-lock connectors • Axial and right-angle connector models • 2m, 5m and 10m cable lengths • PVC (polyvinyl chloride) jacket for typical industrial applications • IP68 rated ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors M12 Junction Blocks Panel Interface Connectors M8 Cables with Quick-Disconnect Part Number Price Length Poles Connectors Jacket Dimensions Wiring Duct M8 Quick-Disconnects Cable Ties CD08-0G-020-A1 $8.75 2m (6.56 ft.) 4 Axial female PVC Figure 1 CD08-0W-020-C1 $8.75 2m (6.56 ft.) 4 Right-angle female PVC Figure 2 Wire CD08-0G-050-A1 $10.50 5m (16.4 ft.) 4 Axial female PVC Figure 1 Flexible Cord CD08-0W-050-C1 $10.50 5m (16.4 ft.) 4 Right-angle female PVC Figure 2 CD08-0G-100-A1 $13.25 10m (32.8 ft.) 4 Axial female PVC Figure 1 CD08-0W-100-C1 $13.25 10m (32.8 ft.) 4 Right-angle female PVC Figure 2 Dimensions (mm) Cable Specifications M8 Use these cables if the sensor pin configuration looks like the connector pin-out below. M8 Connector Multi-conductor Flex Cable Data Cables Wire Management Products Power Supplies Figure 1 DC Converters Length 2m (6.56 ft.) 5m (16.4 ft.) 10m (32.8 ft.) Transformers and Filters Nominal Voltage 30VAC/30VDC Circuit Protection Nominal Current 4A Protection Degree Contact Body Material PUR Contacts Material CuSn Ø Outer Cable Temperature Range Test Equipment ABS Housing Material Conductors Section Tools IEC IP67 0.25 mm2 Enclosures Figure 2 Enclosure Climate Control 4.5 mm Safety: Electrical Components -5° to +70°C (23° to 158°F) Safety: Protective Wear Terms and Conditions Book 3 (14.1) w w w. a u t o m a t i o n d i r e c t . c o m / w i r i n g- s o l u t i o n s Wiring Solutions eWD-81 Prices as of April 16, 2014. Check Web site for most current prices. Compression Mounting Fittings for Temperature Probes Compression Mounting Fittings for Temperature Probes Drives Soft Starters Motors BCF18-125N Pcs/ Wt(lb) Price Pkg Part Number Description Company Information Power Transmission BCF18-125N Compression fitting, brass, for 1/8 inch diameter temperature probes,1/8 inch NPT male thread 1 0.5 $2.50 BCF14-125N Compression fitting, brass, for 1/4 inch diameter temperature probes,1/8 inch NPT male thread 1 0.5 $2.50 BCF18-25N Compression fitting, brass, for 1/8 inch diameter temperature probes,1/4 inch NPT male thread 1 0.5 $3.00 BCF14-25N Compression fitting, brass, for 1/4 inch diameter temperature probes,1/4 inch NPT male thread 1 0.5 $3.00 BCF18-50N Compression fitting, brass, for 1/8 inch diameter temperature probes,1/2 inch NPT male thread 1 0.5 $4.50 BCF14-50N Compression fitting, brass, for 1/4 inch diameter temperature probes,1/2 inch NPT male thread 1 0.5 $3.00 CF18-125N Compression fitting, 316 stainless steel, for 1/8 inch diameter temperature probes,1/8 inch NPT male thread 1 0.5 $6.25 CF14-125N Compression fitting, 316 stainless steel, for 1/4 inch diameter temperature probes,1/8 inch NPT male thread 1 0.5 $6.25 CF18-25N Compression fitting, 316 stainless steel, for 1/8 inch diameter temperature probes,1/4 inch NPT male thread 1 0.5 $7.25 CF14-25N Compression fitting, 316 stainless steel, for 1/4 inch diameter temperature probes,1/4 inch NPT male thread 1 0.5 $7.25 CF18-50N Compression fitting, 316 stainless steel, for 1/8 inch diameter temperature probes,1/2 inch NPT male thread 1 0.5 $10.75 Sensors: Temperature CF14-50N Compression fitting, 316 stainless steel, for 1/4 inch diameter temperature probes,1/2 inch NPT male thread 1 0.5 $10.75 Sensors: Level CFTF-18 Teflon™ ferrule for brass or stainless steel compression fittings and 1/8 diameter temperature probes 5 0.5 $6.00 Sensors: Flow Switches CFTF-14 Teflon ferrule for brass or stainless steel compression fittings and 1/4 diameter temperature probes 5 0.5 $6.50 Motion: Servos and Steppers Motor Controls Sensors: Proximity BCF18-25N Sensors: Photoelectric Sensors: Encoders Sensors: Limit Switches Sensors: Current Sensors: Pressure BCF18-50N Pushbuttons and Lights BB125N-50N CF06-25N 1/4 NPT stainless steel compression fitting for 0.24 inch (6 mm) diameter RTD probe with M12 connector. 1 0.18 $24.00 CF10-50N 1/2 NPT stainless steel compression fitting for 10 mm (0.4 inch) diameter RTD probe with M12 connector. 1 0.20 $25.00 CF18-BC Bayonet compression fitting, for 1/8” diameter probe sheath sensors 1 0.1 $8.00 BB125N-50N Reducing bushing, brass, 1/2 MNPT x 1/8 FNPT, hex head 1 0.1 $4.00 NOTE: CHECK THE CHEMICAL COMPATIBILITY OF THE SENSOR’S WETTED PARTS WITH THE MEDIUM TO BE MEASURED. Stacklights Signal Devices Process Relays and Timers Pneumatics: Air Prep CFTF-14 *Working pressure of compression fitting should not exceed 500 psi. However we recommend any pressure application use a thermowell CF14-125N CF14-50N Pneumatics: Directional Control Valves CF14-25N Pneumatics: Cylinders Pneumatics: Tubing CFTF-18 Pneumatics: Air Fittings CF18-BC Appendix Book 2 CF06-25N CF10-50N Terms and Conditions Book 2 (14.1) w w w. a u to m at i o n d i re c t . c o m / te m p e rat u re - s e n s o rs Temperature Sensors eTE-69 Prices as of April 16, 2014. Check Web site for most current prices. Compression Mounting Fittings for Temperature Probes BCF14-125N BCF14-25N BCF14-50N CF18-25N CF18-50N CF18-125N Dimensions Note: All threaded connections should be hand tightened and then turned 1 to 2 full turns for proper sealing. Actual torque required for a proper seal of NPT threads is influenced by tolerance, sealant, lubricant, etc. ProSense Compression Fittings Part No. BCF18-125N/ CF18-125N BCF14-125N/ CF14-125N BCF18-25N/ CF18-25N BCF14-25N/ CF14-25N BCF18-50N/ CF18-50N BCF14-50N/ CF14-50N CF06-25N CF10-50N Weight (lb) Description “T” Tube O.D. “P” NPT(M) “L” Body “L1” Thread “F” Body “G” Nut Length* Length** Hex** Hex** “NL” Nut Length** 0.5 1/8” OD x 1/8” NPT(M) 0.128/0.132 1/8” NPT(M) 0.909” 0.393” 0.5” 0.433” 0.492” 0.5 1/4” OD x 1/8” NPT(M) 0.253/0.257 1/8”NPT(M) 1.0” 0.393” 0.5” 0.559” 0.5” 0.5 1/8” OD x 1/4” NPT(M) 0.128/0.132 1/4” NPT(M) 1.114” 0.551” 0.551” 0.433” 0.492” 0.5 1/4” OD x 1/4” NPT(M) 0.253/0.257 1/4” NPT(M) 1.188” 0.551” 0.551” 0.559” 0.5” 0.5 1/8” OD x 1/2” NPT(M) 0.128/0.132 1/2” NPT(M) 1.377” 0.748” 0.866” 0.433” 0.492” 0.5 1/4” OD x 1/2” NTP(M) 0.253/0.257 1/2” NPT(M) 1.437” 0.748” 0.866” 0.559” 0.5” 0.18 6 mm OD x 1/4” NPT(M) 0.236/0.240 1/4” NPT(M) 1.174” 0.59” 0.67” 0.55” 0.587” 0.20 10 mm OD x 1/2” NPT(M) 0.394/0.399 1/2” NPT(M) 1.458” 0.55” 1.06” 0.75” 0.608” Note: All dimensions are in inches *  0.07 **  0.03 Note: Once the compression fitting has been fully tightened on the probe, the ferrule will be locked onto the probe and cannot be removed or reused. *Working pressure of compression fitting should not exceed 500 psi. However we recommend any pressure application use a thermowell Book 2 (14.1) eTE-70 Temperature Sensors 1 - 80 0 - 633 - 0405 Prices as of April 16, 2014. Check Web site for most current prices. Bayonet Mounting Adapter for Temperature Sensors Company Information Drives Soft Starters Bayonet Mounting Adapter for Temperature Sensors Motors Pcs/ Wt(lb) Price Pkg Part Number Description BA-078 Bayonet adapter, 7/8 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT 1 0.5 $1.25 BA-100 Bayonet adapter, 1 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT 1 0.5 $1.25 BA-114 Bayonet adapter, 1-1/4 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT 1 0.5 $1.50 BA-112 Bayonet adapter, 1-1/2 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter,1/8 inch MNPT 1 0.5 $1.75 BA-200 Bayonet adapter, 2 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT 1 0.5 $2.00 BA-212 Bayonet adapter, 2-1/2 long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT 1 0.5 $2.25 BA-300 Bayonet adapter, 3 inch long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT 1 0.5 $2.50 BA-312 Bayonet adapter, 3-1/2 long, 7/16 inch outside diameter, 9/32 inch inside diameter, 1/8 inch MNPT 1 0.5 $2.75 CF18-BC Adjustable bayonet compression fitting, for 1/8” diameter probe sheath sensors 1 0.1 $8.00 1 0.1 $4.00 BA-078 Power Transmission Motion: Servos and Steppers Motor Controls Sensors: Proximity Sensors: Photoelectric BA-100 Sensors: Encoders Sensors: Limit Switches Sensors: Current Sensors: Pressure BA-114 BB125N-50N Reducing bushing, brass, 1/2 MNPT x 1/8 FNPT, hex head Sensors: Temperature Sensors: Level NOTE: CHECK THE CHEMICAL COMPATIBILITY OF THE SENSOR’S WETTED PARTS WITH THE MEDIUM TO BE MEASURED. Sensors: Flow Switches Pushbuttons and Lights Stacklights CF18-BC BA-300 BA-112 Signal Devices Process Relays and Timers Pneumatics: Air Prep BB125N-50N BA-312 Pneumatics: Directional Control Valves BA-200 Pneumatics: Cylinders Pneumatics: Tubing Pneumatics: Air Fittings Appendix Book 2 BA-212 Terms and Conditions Book 2 (14.1) w w w. a u to m at i o n d i re c t . c o m / te m p e rat u re - s e n s o rs Temperature Sensors eTE-71 Prices as of April 16, 2014. Check Web site for most current prices. Thermocouple and RTD Temperature Range Thermocouple Temperature Range THMK-C06-04 THMK-C12-04 THMK-C18-04 32 to 2100°F (0 to 1149°C) THMK-H06L01-03 THMK-H12L01-03 THMK-H18L01-03 THMK-T06L06-03 32 to 2100°F (0 to 1149°C) lead wire transition rated to THMK-T12L06-03 204°C (400°F) THMK-T18L06-03 TTD25C-20-0300F-H 0 to 300°F (-17.8 to 148.9°C) TTD25N-20-0300F-H THMJ-A01L04-01 THMJ-A01L06-01 THMJ-A01L10-01 THMJ-A01L10-02 THMJ-B01L06-01 THMJ-B01L06-02 THMJ-B02L06-01 THMJ-B02L06-02 THMJ-D08L04-01 THMJ-D08L06-01 THMJ-D08L10-01 32 to 900°F (0 to 482°C) THMJ-D08L10-02 THMK-A01L04-01 THMK-A01L06-01 THMK-A01L10-01 THMK-A01L10-02 THMK-B01L06-01 THMK-B01L06-02 THMK-D08L04-01 THMK-D08L06-01 THMK-D08L10-01 THMK-D08L10-02 THMJ-T06L06-01 32 to 970°F (0 to 521°C), lead wire transition rated to 400 °F THMJ-T12L06-01 (204 °C) THMJ-T18L06-01 THMJ-P06-01 32 to 970°F (0 to 521°C), plug THMJ-P12-01 rated to 400 °F (204 °C) THMJ-P18-01 THMJ-C04-03 THMJ-C04R-03 THMJ-C06-01 THMJ-C06-02 THMJ-C06-03 THMJ-C06R-03 THMJ-C12-01 THMJ-C12-02 THMJ-C12-03 32 to 1330°F (0 to 720°C) THMJ-C12R-03 THMJ-C18-01 THMJ-C18-02 THMJ-H04L01-02 THMJ-H06L01-01 THMJ-H06L01-02 THMJ-H12L01-01 THMJ-H12L01-02 THMJ-H18L01-01 Thermocouple Temperature Range THMJ-T06L06-02 THMJ-T12L06-02 THMJ-T18L06-02 THMJ-P06-02 THMJ-P12-02 THMJ-P18-02 THMK-C04-03 THMK-C04R-03 THMK-C06-01 THMK-C06-02 THMK-C06-03 THMK-C06R-03 THMK-C12-01 THMK-C12-02 THMK-C12-03 THMK-C12R-03 THMK-C18-01 THMK-C18-02 THMK-H04L01-02 THMK-H06L01-01 THMK-H06L01-02 THMK-H12L01-01 THMK-H12L01-02 THMK-H18L01-01 THMK-T06L06-01 THMK-T06L06-02 THMK-T12L06-01 THMK-T12L06-02 THMK-T18L06-01 THMK-T18L06-02 THMK-P06-01 THMK-P06-02 THMK-P12-01 THMK-P12-02 THMK-P18-01 THMK-P18-02 THMK-B02L06-01 THMK-B02L06-02 THMT-P06-01 THMT-P12-01 THMT-P18-01 THMT-T06L06-01 THMT-T12L06-01 THMT-T18L06-01 TTD25C-20-0100C-H TTD25N-20-0100C-H TSD25N-0P-0284-H TSD25N-AP-0284-H 32 to 1330°F (0 to 720°C) lead wire transition rated to 400 °F (204 °C) 32 to 1330°F (0 to 720°C) plug rated to 400 °F (204 °C) 32 to 1700°F (0 to 927°C) 32 to 1700°F (0 to 927°C) lead wire transition rated to 400 °F (204 °C) RTD Temperature Range RTD1-R01-01 RTD1-S04-01 RTD1-S04-02 RTD1-S04-03 RTD1-S04-04 RTD1-B01L06-01 RTD1-B02L06-01 RTD1-C04-03 RTD1-C04R-03 RTD1-C06-01 RTD1-C06-03 RTD1-C06R-03 RTD1-C12-01 RTD1-C12-02 RTD1-C12-03 RTD1-C12R-03 RTD1-C18-01 RTD1-C18-02 RTD1-H04L01-02 RTD1-H06L01-01 RTD1-H06L01-02 RTD1-H12L01-01 RTD1-H12L01-02 RTD1-H18L01-01 RTD1-P06-01 RTD1-P12-01 RTD1-P18-01 RTD1-D08L10-01 RTD1-T06L06-01 RTD1-T12L06-01 RTD1-T18L06-01 40 to 185°F (-40 to 85°C) -58 to 572°F (-50 to 300°C) -58 to 572°F (-50 to 300°C) Plug rated to 400°F (204°C) -58 to 572°F (-50 to 300°C), lead wire transition rated to 400°F (204°C) 32 to 1700°F (0 to 927°C) plug rated to 400 °F (204 °C) 32° to 900°F (0° to 482°C) J, K, & T Thermocouple Color Code -328 to 700°F (-200 to 371°C) plug rated to 400 °F (204 °C) White J Red -328 to 700°F (-200 to 371°C), lead wire transition rated to 400 °F (204 °C) Yellow K Red 32 to 212°F (0 to 100°C) Blue -4 to 284°F (-20 to 140°C) T Red + + + - Book 2 (14.1) eTE-76 Temperature Sensors 1 - 80 0 - 633 - 0405