Protect Blue

   EMBED


Share

Transcript

Protect Blue Sales Presentation June 2013 Jürgen Rüth CONTENTS A Introduction B Data Center C Protect Blue Description D Operating Modes E Battery Connection F Technical Details G Communication H Protect Blue TCO I References J Terminal Cabinets 2 A. INTRODUCTION 3 DEMAND FOR NEW DATA CENTER AND GREEN SOLUTIONS ARE INCREASING THE NEED TO DEVELOP ENERGY EFFICIENT SOLUTIONS • GENERAL MARKET ENVIRONMENT • Data consumption levels continue to surge – Developments like cloud computing lead to a boom in demand for new data centre capacity • Total cost of ownership focus from customer – Especially, in data center business, where energy consumption is a huge part of operating expenses • UPS market for >100 KVA is forecasted to grow with 10% p.a. until 2015 • World energy consumption expected to nearly double over first half of this century 4 COMMERCIAL UPS EXPECTED TO THRIVE AS THE GLOBAL DIGITAL ECONOMY MOVES INTO THE "CLOUD" Total Data Center UPS Market: Key Market Drivers Critical need for high uptime in data centers Poor quality of utility power supply Total Data Center UPS Market 2011-2017 Units ['000] Need for higher energy efficiency 80 GROWING DATA CENTERS Cloud Computing Virtualisation Storage Smartphone & Tablets applications Smart Broadcasting (content storage) 2007 86 90 95 2008 2009 2010 2011 2012 110 2013 119 2014 130 2015 2016 158 2017 Revenues [$bn] 2,9 2007 Source: Frost & Sullivan 92 102 143 3,3 2008 2,9 3,1 3,3 3,4 3,0 2009 2010 2011 2012 2013 3,7 2014 3,9 2015 4,2 2016 4,6 2017 5 B. DATACENTER 6 21ST CENTURY CLOUD COMPUTING “DIGITAL REVOLUTION” • Cloud Computing refers to delivery of computing and storage capacity as a service to a heterogeneous community of end-recipients • End-Users access cloud based applications through a Web Browser or a light weight desktop or mobile App while the business software and data are stored on servers at remote area. • Cloud computing relies on sharing of resources to achieve coherence and economies of scale similar to utility 7 WHERE TO STORE ALL THESE DATA? Servers and Storage capacity are accommodated within a facility called: DataCenter 8 What is a Datacenter? A Datacenter is a facility used to house computer systems and associated components such as: • Servers (Computers) • Storage systems (Hard Disks) • Cooling systems • Power Back-up supplies • • • Diesel Generators UPS/ Battery Systems Power Distribution units • Telecommunication systems • Fire suppression • Security devices 9 DATACENTER DETAILED DESCRIPTION Servers Storage Cooling Systems UPS PDU Server Rack Datacentre 10 Power Consumption in Datacenter is a Major Issue Critical Loads Servers 36% 50% Dx Cooling Systems AEG PS Focus 11% UPS inefficiency 3% Lighting 11 DATA CENTERS BY SIZE Focus Protect Blue SMALL MEDIUM LARGE < 10 racks, < 200 m2 < 50 racks, < 1000 m2 > 50 racks, > 1000 m2 SMEs, Corp regional offices MLEs, Corp Corp, colo Price, ease of supply TCO, green, technology TCO, green, technology, legislation Standard solutions, CTO service Customised standard, ETO service ETO (customised engineering solution and services) End user End user, FM, IT, CIO Property services, building services, CE, contractor Tier 1 (N Redundancy) Tier 2+ (N+1 Redundancy) Tier 3, 4 (2N, 2N+1 Redundancy) 5KW – 80KW 80KW – 500KW 500KW – > several MW For 300 small data centers there are 30 medium and 1 large facility 12 C. PROTECT BLUE DESCRIPTION 13 Protect Blue – Main Features Main Features • Modular and flexible building block design • Paralleling for Multi-Megawatt solutions • Innovative 3 level IGBT technology • Bi-directional IGBT rectifier • High efficiency + • Low input THDi • High input power factor • Wide range of output power factor • Easy maintainable • High quality design (Made in Germany) 250kVA Power Block 14 Protect Blue – Intelligently Efficient Protect Blue 250kVA Power Block Design • • • • • Modular Scalable Flexible Field Upgradeable Grows With Customer’s Needs “Building Block” - Architecture • • • • • Up to 16 Power Blocks (250kVA) per UPS N+1 Redundancy Output Power-Factor 0,9 ind./cap. (225 kW) Front access to all important components (Rectifier, Inverter, SBS) Air exhaust at the top of the cabinet Paralleling Capability for Multi-Megawatt Solutions Example: 4MVA UPS 15 Protect Blue – Main Technical Data Rectifier Battery Nominal Input Voltage 3 x 400V, 3 Phases+N Nominal DC-Voltage 480V Input Voltage Range 340 – 440V Charging Characteristic IU Power Frequency (Mains) 50/60Hz (adjustable) THD(i) < 3% Power Factor cos ϕ > 0.99 DC-Link Voltage 750-800V Static Bypass Nominal Voltage 3 x 400V (380-415V, adjustable) Frequency 50/60Hz (adjustable) 1%, 3 x 400V, 3 Phases Frequency 50/60Hz (adjustable) Synchronization Range Inverter Precision Static/Dynamic Nominal Voltage 10% adjustable Transfer time 0ms Admissible overload 500% for 10ms 2% Communication Total Harmonic Distortion <3% Overload response 125% for 10min, 150% for 1 min Remote Signal Contact GSM Modem Crest Factor 3:1 RS232/RS485 COM Server Max Short Circuit current 270% of rated current SNMP Ethernet Power Factor range 0.1 inductive to 0,1 capacitive Modbus IEC61850 Profibus 16 Protect Blue Block Diagram Thyristor bypass ~ ~ 3 Level IGBT 3 Level IGBT ~ 750V Mains Supply 3 Phases + N, 400V ~ AC Load 3 Phases + N, 400V 480 V Battery Voltage Booster/Charger 17 Protect Blue HIGHLIGHTS Thyristor bypass ~ ~ 3 Level IGBT 3 Level IGBT ~ Mains Supply 3 Phases + N, 400V 750V ~ AC Load 3 Phases + N, 400V Rectifier and Inverter built with the latest IGBT technology 480“3-Level” V Battery Voltage will give us High efficiency already at 20% of outputBooster/Charger power Perfect designed to secure your load Bidirectional rectifier enables the customer to start a full load Under case conditions: battery worst capacity check (even with partial Inverter load) Mains failure & 150% overload without additional load bank !! 18 Protect Blue – Communication Structure Parallel CAN-BUS Rectifier Control Units Inverter (500kbps) Next Power Block MCI DOU-CAN-BUS (100kbps) Touch-Display and Operation Unit (DOU) DOU-CAN-BUS Remote signaling • Dry Contacts • Opto-coupler Communication Interfaces Port 1 Black Box RJ45 Port 2 Ethernet VNC Client for Remote Monitoring DSL / VPN Remote Service module CAN Port 1 Telecom MultiCOM MCE RJ45 MultiCOM IEC61850 RJ45 SNMP Adapter RJ45 CompuWatch SNMP-Adapter Status Signals UPS modem MultiCOM MCC Monitoring via NMS (SNMP), UNMS, Web Browser,CompuWatch MultiServer Shutdown Notify via Netmessage, E-Mail Modbus RTU Alarm Management Ethernet To SmartGrid Control Platform (future) Analogue/ISDN/GSM Remote Monitoring Ethernet COM-Server function Modbus TCP (future) 19 Protect Blue – Perfect internal redundancy Power supply concept DC Bus SBS Input PSU 1 Rectifier Interface Rectifier Input PSU 2 Rectifier Reliability Enhanced Inverter Inverter interface • Separate control boards for Rectifier and Inverter with: SBS • separate microprocessors and power supplies: Multi-Processor Technology Balancer • Internal Redundant Power Supply for each µP with three independent input power sources. Booster - Charger • Control boards 100% digital: No Potentiometers! • Independent control functions 20 Protect Blue (3 Level rectifier) L1 L2 L3 DC-Link N AC Input 3 Level 21 Protect Blue (3 Level inverter & N-balancing) AC Output X1 X2 X3 DC-Link N N-Balancing 3 Level 22 3 Level versus 2 Level Technology 2-Level L3 L1 L2 L3 N DC-Link L2 DC-Link L1 3-Level Advantages of 3 Level Topology • Reduced IGBT blocking voltage (600V vs. 1200V) • Reduced switching losses (Factor 3-5) lead to higher efficiency (although higher no. of IGBT’s) • Low harmonic distortion of inverter output voltage • High efficiency already at 20% of output power • Low filter effort 23 Protect Blue – Features Rectifier and Inverter built with the newest “3-Level” IGBT technology − Very high efficiency: 95% from 20% load 96% from 40% load − Real online operation − 99% efficiency in ECO Mode − Low THDI max. 3% 2-Level IGBT − Input Power Factor >0,99 3-Level IGBT 24 Protect Blue features and Customer Benefits Features High Input Power Factor (0.99) Customer Benefits • Lower Installation costs • Smaller cable size • Smaller protection ratings (Fuse or MCCB) • Lower upstream Genset rating required • Lower Electricity Costs Message • Lower CAPEX 25 Protect Blue features and Customer Benefits Features Low THDi (<3%) Customer Benefits • Better compatibility in all installations • No need to oversize upstream Gensets • No need to oversize upstream tripping coils • No need to oversize input connections cables Message • Lower CAPEX 26 Protect Blue features and Customer Benefits Features High Efficiency in double conversion – AC to AC (96% typical) Customer Benefits • • • • Low heat dissipation Greener operation Lower operating costs Reduced cooling requirements Message • Lower operating costs 27 Protect Blue features and Customer Benefits Features Design philosophy Customer Benefits • Use of high performance components (IGBT, Fans, Chokes etc..) • 15 years estimated design lifetime • Internal cooling and components accommodation to limit thermal stress. • Industrial grade design solution • Low operating costs Message • Reliability • Quality 28 Key messages • Technical performance: • High Efficiency • Unity input power factor • Low Input THDi Reliability • 0.9 output power factor Quality • Technology: • Three Level IGBT • Bi-directional Rectifier bridge • Maintainability: Services • Components Accessibility Performance • Components accommodation • Sliding power bridges • Services: • Full AEG PS service solutions available Maintainability • Reliability: Technology • Quality design electrical and mechanical design • 15 years extended lifetime 29 D. OPERATING MODE 30 Operation Modes UPS Operation Modes: Standard: VFI Optional: Idle & ecoMode Single Operation 250kVA powerblock as standalone UPS Parallel operation: Max. 5 powerblocks working in a line (one Touch Display ) N+1 operation N+0 operation for power increase Decentralized Bypass Max 4 lines paralleled (overall max 16 powerblocks) 31 Protect Blue – Dimensions and Footprint (Stand alone) Rating (kVA) Width (mm) 250 1000 Building Block - Architecture • Height = 1900 mm • Depth = 900 mm 500 750 3000 5000 • Max. 16 power blocks per system • 3 distribution blocks (500kVA, 1MVA, 1.25 MVA ) to complete power system • Redundant operation (e.g. N+1) 1000 6000 • Easy front access to all important components (Rectifier, Inverter, SBS) • Air exhaust at top of cabinet 1250 7400 These pictures are for information only and are not contractually binding 32 Protect Blue – Technical Concept: Parallel UPS Parallel Operation with up to 4 UPS lines 4x 250 kVA 4x 500 kVA 4x 750 kVA 33 Protect Blue – Technical Concept: Parallel UPS 4x 1000 kVA 3x 1250 kVA Max. 16 Power Blocks per UPS System 34 Protect Blue – Innovative Scalability Hypothesis: • Start with 500kVA UPS Configuration with 10minutes autonomy • Pre-install a 1000kVA Distribution Board • Add 250kVA Modules horizontally Pre-installed Distribution Panel 1 2 0 500kVA 1 750kVA 2 1000kVA Secured Power Mains Supply 0 1 2 Battery DC Bus Pre-installed Battery Strings Additional Strings Additional Strings 35 Parallel operation (Normal mode) 20% 20% 20% 20% 20% 100% System load 36 Parallel operation (ECO mode) 100% SBS load 37 Parallel operation n+1 redundancy with Idle-mode +1 +1 1000kVA 750kVA System load 38 E. BATTERY 39 Technical Data Battery Voltage Nominal battery voltage 480V Voltage range: − min. 384V − max. 576V Backup time 10 – 60min at P_nom. 40 Protect Blue –1000kVA with distributed Batteries Critical Loads Mains Supply Battery Battery These pictures are for information only and are not contractually binding Battery Battery 41 Protect Blue –Central Batteries (max. 1MVA per line) Mains Supply Critical Loads Example = 4MVA Battery These pictures are for information only and are not contractually binding 42 F. TECHNICAL DETAILS 43 Protect Blue – Technical Details Touch Screen Display 44 Architecture of Building Block (2) Cooling Fans Communication Boards Inverter Control Board Fuses Fuse Protection Aux. Power Supplies 45 45 Architecture of Building Block (3) Cooling Fans Rectifier Thyristor bypass Inverter Removable Bridge Removable Power Supply 46 46 G. COMMUNICATION 47 Protect Blue – Display 7” wide-screen LCD Touch Display Settings Power Flow Lock screen Help Screenshot • Intuitive screen design based on folders • “One-Touch” for most important events and measuring values • Urgent messages displayed directly • 3 LED show UPS status when LCD is in standby mode Overall System status Additional folders for Power Blocks will appear here if connected Communication Status These pictures are for information only and are not contractually binding 48 Protect Blue – Communication Structure Parallel CAN-BUS Rectifier Control Units Inverter (500kbps) Next Power Block MCI DOU-CAN-BUS (100kbps) Touch-Display and Operation Unit (DOU) DOU-CAN-BUS Remote signaling • Dry Contacts • Opto-coupler Communication Interfaces Port 1 Black Box RJ45 Port 2 Ethernet VNC Client for Remote Monitoring DSL / VPN Remote Service module CAN Port 1 Telecom MultiCOM MCE RJ45 MultiCOM IEC61850 RJ45 SNMP Adapter RJ45 CompuWatch SNMP-Adapter Status Signals UPS modem MultiCOM MCC Monitoring via NMS (SNMP), UNMS, Web Browser,CompuWatch MultiServer Shutdown Notify via Netmessage, E-Mail Modbus RTU Alarm Management Ethernet To SmartGrid Control Platform (future) Analogue/ISDN/GSM Remote Monitoring Ethernet COM-Server function Modbus TCP (future) 49 PROTECT BLUE - SNMP ADAPTER Features: Agent for RFC1628 MIB UPS standard MIB Embedded Web-Server – Monitoring via Web and Wap – Configuration via Web Embedded Event Manager – Start of different Jobs – Net Broadcast – E-Mail Monitoring of environmental conditions – Temperature, Humidity, GenSet, Fire, Air condition, Smoke shutter... Support Software products – Network Management Software „NMS“ – NMS special for Power Supply Systems – Shutdown Software “CompuWatch” – Direct multi-server shutdown of different OS with communication modules with SSL coding 50 PROTECT BLUE - ENVIRONMENT MANAGER FOR SNMP ADAPTER Features: Eight analogue inputs for sensor – Temperature sensor – Humidity sensor – Kombi sensor – Custom sensor (0-10V) Four digital inputs – Smoke detector – Motion detector – 0-48V Four digital outputs – Flash Light – 500mA Configuration and Monitoring – Via embedded Web server of SNMP Adapter 51 PROTECT BLUE – BACnet The architecture of the BACnet protocol BACnet is a communications protocol for building automation and control networks. The protocol is based on four layers of the OSI model: BACnet-Interface BACnet Gateway: Physical Layer: 10/100Base-T Protocoll: BACnet IP UDP Port: 47808 Mode: Full- or Half Duplex (autosense) Data rate: 10/100Mbps Segment lengh: 100m 52 PROTECT BLUE - MODBUS INTERFACE FOR SCADA RS-485 Modbus RTU Technical data: •Transm. mode: Half duplex •Transm. code: RTU •Transm. rate: 1200 - 19200 bps •Startbit: 1 •Data bits: 8 •Parity: none, odd, even •Stop bits: 2 if no parity 1 if parity SCADA or Facility Management SCADA UPS Line 1 UPS Line 2 SCADA = Supervisory Control And Data Acquisition 53 PROTECT BLUE - OPC SERVER OLE1 FOR PROCESS CONTROL UPS Line1 UPS Line 2 UPS Line 3 Digital inputs Digital inputs Fieldbus OPC Server RS485 - Modbus OPC Server Network / LAN / WAN / Intranet OPC Server Fieldbus Facility Management Software OPC Client OPC Client SAP R/3 1 OLE=Object Linking Embedded 54 REMOTE DISPLAY VIA VNC CLIENT Requirements: Touch display must be connected to the local network 55 PROTECT BLUE - MONITORING WITH SNMP ADAPTER AND ENVIRONMENT MANAGER Monitoring of UPS and Data Centre with SNMP adapter and Environment Manager Transmission of netmessages and E-Mails Server-Raum UPS Power failure UPS-alarm Room-temperature high Air-condition fault Smoke detector active GS: EZA: Smoke-shutter Air condition W S: Menü: Betriebsdauer: Log Saving of all events Shutdown-control via SSL Autonomy time near end Smoke-shutter closed Air-condition fault Internet Explorer E-Mail Intranet UPS Monitor SMS 56 PROTECT BLUE - MULTISERVER-SHUTDOWN IN A NETWORK MultiServer-Shutdown in a network Powerfail RCCMD RCCMD RCCMD SNMP Adapter RCCMD RCCMD Shutdown of Operating Systems on server Send E-Mails TCP/IP UPSmonitor or WEB Browser Administrator User Send Net message: Attention: The network is shutting down in 5 minutes!!! 57 PROTECT BLUE - WEB-BASED NETWORK MANAGEMENT SOFTWARE Basic screen of web-based Network Management Software UNMS II Web based Network management Software for Power Supply Systems Software application UNMS communicates via TCP/IP with SNMP Adapter. IIS from Microsoft is necessary. 58 PROTECT BLUE - WEB-BASED NETWORK MANAGEMENT SOFTWARE Standard screen of web-based Network Management Software Standard screen for 25 UPS devices 59 PROTECT BLUE - WEB-BASED NETWORK MANAGEMENT SOFTWARE Example of customized screen of web-based UNMS Main screen of Germany map 60 WEBSERVER-BASIERTE NETZWERK MANAGEMENT SOFTWARE 61 H. PROTECT BLUE TCO 62 Protect Blue Energy Saving for 250kVA UPS Protect Blue Conventional UPS AC/AC efficiency 96% 94% Power posses (Watts) @ 225kW 9000 13500 Costs of power losses over one year (€) 7.884 11.826 Costs of power Losses over 5 years (€) 39.420 59.125 Protect Blue savings over one year (€) 3.942 Protect Blue savings over 5 years (€) 19.170 * kWh price: 0.1Euro Additional savings due to reduced cooling effort (approx. 14.000€ in 5 years) 63 Protect Blue versus Conventional UPS Operating Costs for 250kVA UPS 220,000 Conventional UPS 200,000 +41% 180,000 160,000 Protect Blue 140,000 120,000 100,000 80,000 60,000 40,000 20,000 0 Capex Year 1 Year 2 Year 3 Year 4 Year 5 Year 6 Year 7 Year 8 Year 9 Year 10 Protect Blue offers a better Total Cost of Ownership 64 Summary • Design Philosophy – Different key drivers for industrial and commercial UPS lead to different design philosophies and consequently different technologies – New product “Protect Blue” (250kVA power block) combines advantages of robust Industrial UPS and the requirements of a Commercial UPS • Made in Germany – Developed and built with over 60 years AEG experience in Power Supply Systems • High Reliability, Long Lifetime, Low Operating Costs – High quality components (capacitors, fans, chokes). – Designed for a lifetime of more than 15 years (Made in Germany) – Better Total Cost of Ownership • Short Delivery Time – Planned batch production, power blocks are available from stock • Easy to Maintain – Power blocks can be repaired on site, simplified spare part handling, worldwide service 65 65 I. TERMINAL CABINETS 66 Protect Blue – Standard Terminal Cabinets Main Features • Compact • Provides full maintainability for each PB • Simplifies later on system extension Ratings 500kVA Terminalblock • 500kVA • 1000mm wide • 1000kVA • 2000mm wide (2 x 1000mm) • 1250kVA • 2400mm wide (2 x 1200mm) 1000kVA Terminalblock 67 Protect Blue 1000kVA with Standard Terminal Cabinets: Single Line Batterie Fuse Breaker Rectifier Fuse Breaker SBS Fuse Breaker Output Breaker 68 Protect Blue – Standard Terminal Cabinets: Inside Rectifier Fuse Breaker Batterie Fuse Breaker SBS Fuse Breaker Output Breaker 69 Modular Distribution Design Rectifier SBS Manual bypass UPS output Battery switches 70 71 Distribution for 2 or 3 Powerblocks Rectifier SBS Manual bypass UPS output Battery switches Key features: Design for 2 or 3 Powerblocks Single mains input for Rectfier and SBS for up to to 5 battery strings 72 Distribution for 4 or 5 Powerblocks Rectifier SBS Manual bypass UPS output Battery switches Key features: Design for 4 or 5 Powerblocks Single mains input for Rectfier and SBS for up to to 5 battery strings 73 Distribution for 2 or 3 Powerblocks (sep. mains input for Rec & SBS) Rectifier SBS Manual bypass UPS output Battery switches Key features: Design for 2 or 3 Powerblocks Sep. mains input for Rectfier and SBS for up to to 5 battery strings 74 Distribution for 4 or 5 Powerblocks (sep. mains input for Rec & SBS) Rectifier SBS Manual bypass UPS output Battery switches Key features: Design for 4 or 5 Powerblocks Sep. mains input for Rectfier and SBS for up to to 5 battery strings 75 J. REFERENCE LIST 76 Customer reference list CUSTOMER / PROJECT PRODUCTS Cern Data Center - Hungary 33 x 250kVA Radius Data Center – Russia 2 x 250kVA Wind Telecom – Italy 8 x 250kVA EMC-Hostco Munich 2 x 250kVA Radius Data Center – Russia 16 x 250kVA 77 QUESTION? 78 Thanks for your attention 79