Preview only show first 10 pages with watermark. For full document please download

Protecto 19 1000-3000e - J. Schneider Elektrotechnik Gmbh

   EMBED


Share

Transcript

J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line USV-Anlage proTECTO 19´ 1000-3000 On-line UPS-system according to DIN EN 62040-3 (VFI-SS-111) with sinus soidal output voltage in each operation mode, RS232 interface and Shutdown-Software for Windows NT/2000/XP/2003/Vista, Novell and Linux system software. The back-up time of the system can be increased by connecting additional external battery modules. Model proTECTO 19´ 1000 1500 2200 2200 ER 3000 3000 ER 1000 900 1500 1350 2200 1980 2200 1760 3000 2700 3000 2400 7 12 6 10 rating rating in VA rating in W back-up time back – up time in minutes 100% load 50% load 6 10 0 0 5 9 0 0 input nominal voltage input voltage range at 50% load input voltage range at 100% Last input frequency range nominal frequency tolerance of frequency nominal current in A (batteries are completely charged, input voltage 230 Volt) inrush current power factor (cos ϕ) harmonic distortion (THDI) „Hold-up time“ (back-up time which can be realized without switching on the battery- there is no interruption of the output voltage) proTECTO 19´ 04-2011 Technical modifications possible 220 / 230 / 240 V AC 140 – 276 V 184 – 276V 45 up to 65 Hz 50 Hz standard, configurable on 50 Hz, 60 Hz or auto select with software ± 5 Hz 5 7 10,5 11,5 14 15 < 6% page 1 of 9 < nominal current > 0,99 < 10% <40 ms J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line USV-Anlage proTECTO 19´ 1000-3000 Model proTECTO 19´ 1000 1500 2200 2200 ER 3000 3000 ER output output voltage tolerance of the output voltage - static tolerance of the output voltage - dynamic (load impact 0 to 100%) voltage reset after dynamic variation waveform of the output voltage output frequency in normal operation rate of frequency adjustment output frequency in battery operation voltage distortion / linear load voltage distortion / non-linear load power factor at the output Crest factor according to EN 50091-1 (peak current to RMS-current) Efficiency at nominal load / mains operation Netzbetrieb efficiency at ECO operation 230 V (switchable on 220 or 240 V) ± 1% < 5% < 20 ms sinus soidal 50 or 60 Hz ± 5 % 1 Hz / s 50 or 60 Hz ± 0,2 % < 2% < 4% < 3,5% 0,9 up to 3:1 89% 90,5% 91,7% 92,65% 98 % Overload overload: 100% < load < 110% overload: 110% < load < 150% short-circuit-current Bypass-line available: Bypass aktiv after 2 sec. Blocked after 120 sec. Bypass-Leitung not available: blocked after 60 sec. Bypass-line not available: Bypass aktiv after 2 sec. Blocked after 120 sec. Bypass-line not available: blocked after 60sec. >1,5x I nom for 0,5 seconds bypass voltage tolerance for switch over tolerance of frequency switch over 180 – 264 Volt ± 5Hz ca. 4 ms battery nomial voltage number of modules nominal capacity per module type life duration recharge time recharge current battery test 36 V 3 7 Ah 36 V 72 V 72 V 72 V 72 V 3 6 * 6 * 9 Ah 7 Ah * 9 Ah * Closed and maintenance-free 5 years (depending on environmental conditions) <4 hours (80% Ah) 0,9 A 0,9 A 0,9 A 6A 0,9 A 6A automatically each 40 hours * external batteries proTECTO 19´ 04-2011 Technical modifications possible page 2 of 9 J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line USV-Anlage proTECTO 19´ 1000-3000 Model proTECTO 19´ 1000 1500 2200 2200 ER 3000 3000 ER interfaces sub-D 9 Pin socket slot RS 232 interface slot for communication- plug-in card connections input output IEC 10 A 8 x IEC 10 A input fuse of the UPS (thermal fuse) in A DC-connection for battery extension Energy share Yes IEC 16 A 8 x IEC 10 A 1 x IEC 16 A 7 12 16 No Yes Yes protection Protections surge voltage stability over current – short ciruit – over voltage – under voltage heat – deep discharge protection of the batteries 2 VDR x 300 Joule norms and regulations safety EMV / RFI operational requirements EN 62040-1-1; EEC regulation 73/23 and 93/68 EN 62040-2; EEC regulation 89/336 EN 62040 – 3 VFI-SS-111 environmental conditions environmental temperature noise level in 1m distance 0 to 40°C < 40 dB(A) cabinet material colour protective system sheet metal / front plastics darkgrey RAL 5004 IP 20 dimensions dimensions (h x w x d) in mm 450x87x425 450x87x625 weight weight in kg proTECTO 19´ 04-2011 Technical modifications possible 17,5 page 3 of 9 18 30,5 15* 31 15* *external batteries J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line USV-Anlage proTECTO 19´ 1000-3000 Model proTECTO 19´ 1000 1500 2200 2200 ER 3000 3000 ER 1 - 1 scope of delivery Manual in german language Schuko/IEC mains cable IEC/IEC connection cable plug for battery extension RS232 connection cable and USB Shutdown-Software for Windows 95/98/NT/2000/XP, Novell and Linux system software (Download) proTECTO 19´ 04-2011 Technical modifications possible Yes 1 2 1 Yes page 4 of 9 J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line USV-Anlage proTECTO 19´ 1000-3000 view of the UPS front side extensible, rotation display demountable front cover Lock-out release display connector battery pack switch ON/OFF cover profile battery pack proTECTO 19´ 04-2011 Technical modifications possible page 5 of 9 J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line USV-Anlage proTECTO 19´ 1000-3000 REAR SIDE Model 1000VA / 1500VA Model 2200VA / 3000VA RS232 communication interface adapter battery extension(Option) USB-Port output socket IEC 10A output socket IEC 16A mains plug IEC 16A slot for communication cards mains plug IEC 10A cooling air fan thermal fuse input Control terminals proTECTO 19´ 04-2011 Technical modifications possible page 6 of 9 J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line USV-Anlage proTECTO 19´ 1000-3000 VIEW OF THE DISPLAY button “SEL” display of charge of battery ON button set up - range button “STAND-BY” Maintenance necessary correct operation Timer mains operation Display of nominal values battery operation Stand-by / alarm Load supplied by bypass EnergyShare Display of battery load status proTECTO 19´ 04-2011 Technical modifications possible page 7 of 9 J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line USV-Anlage proTECTO 19´ 1000-3000 CONNECTION RS232 connection RS232 PIN # 1 2 3 4 5 6 7 8 9 SIGNAL programmable output *: [preset: UPS blocked] TXD RXD programmable input **: [preset: switched off] GND DC-supply (Imax = 20mA) programmable input **: [preset: out of action] programmable output *: [preset:pre-alarm for end of discharge] programmable output *: [preset: battery operation] comments (*) Opto isolated contact max. +30Vdc / 35mA. These contacts can be linked to other events with a corresponding software (**) Opto isolated control +5÷15Vdc. These contacts can be linked to other events with a corresponding software For further information concerning the interfaces at the UPS please have a look at the manual. COMMUNICATION SLOT The UPS-systeme includes a slot for optional communication cards (look at picture beside). This way the unit can communicate by using the most important communication standards. Some examples: • Second communicationport RS232 and USB • Serial reproducer • Mains card Ethernet with TCP/IP, HTTP and SNMP report • card for report converter JBUS / MODBUS • card for report converter PROFIBUS • card with potential relays-contacts ProTECTO 19´ 04-2011 Technical modifications possible page 8 of 9 J. Schneider Elektrotechnik GmbH Postfach 2327, 77613 Offenburg * Helmholtzstr. 13, 77652 Offenburg Technical Data On-Line USV-Anlage proTECTO 19´ 1000-3000 Example for the connection of the signals to RS232 port ProTECTO 19´ 04-2011 Technical modifications possible page 9 of 9